ADIC-INTELLIGENT-STORAGE-MIB
118 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises IpAddress |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.3764 | Nodeadic | |||
| 1.3.6.1.4.1.3764.1 | Nodestorage | |||
| 1.3.6.1.4.1.3764.1.1 | Nodeintelligent | |||
| 1.3.6.1.4.1.3764.1.1.10 | NodeproductAgentInfo | |||
| 1.3.6.1.4.1.3764.1.1.10.1 | ScalarproductMibVersion | read-only | mandatory | MIB version identifier. |
| 1.3.6.1.4.1.3764.1.1.10.2 | ScalarproductSnmpAgentVersion | read-only | mandatory | SNMP agent version identifier. |
| 1.3.6.1.4.1.3764.1.1.10.3 | ScalarproductName | read-only | mandatory | Name of ADIC branded product. Uniquely identifies the product, independent of OEM. |
| 1.3.6.1.4.1.3764.1.1.10.4 | ScalarproductDisplayName | read-only | mandatory | Name of this agent for display purposes. May be customized for OEM. |
| 1.3.6.1.4.1.3764.1.1.10.5 | ScalarproductDescription | read-only | mandatory | A short description of this SNMP agent. |
| 1.3.6.1.4.1.3764.1.1.10.6 | ScalarproductVendor | read-only | mandatory | Name of the product vendor or OEM. |
| 1.3.6.1.4.1.3764.1.1.10.7 | ScalarproductVersion | read-only | mandatory | String Format: MNNO.TVBBBPP Examples 1. 091a.TR054 Version 0.91, build 54 of the RCS test code for ADIC 2. 100A.GM052 Version 1.00, build 52 of the MCB GA cand… |
| 1.3.6.1.4.1.3764.1.1.10.8 | ScalarproductDisplayVersion | read-only | mandatory | The version identifier according to the vendor or OEM. |
| 1.3.6.1.4.1.3764.1.1.10.9 | ScalarproductLibraryClass | read-only | mandatory | Basic library includes minimal connectivity hardware. Intelligent library includes SAN appliances and value-added features. |
| 1.3.6.1.4.1.3764.1.1.10.10 | ScalarproductSerialNumber | read-only | mandatory | The serial number of the entire library. |
| 1.3.6.1.4.1.3764.1.1.20 | NodeglobalData | |||
| 1.3.6.1.4.1.3764.1.1.20.1 | ScalaragentGlobalStatus | read-only | mandatory | Current overall status of the agent. |
| 1.3.6.1.4.1.3764.1.1.20.2 | ScalaragentLastGlobalStatus | read-only | mandatory | The status before the current status which induced an initiative to issue a global status change trap. |
| 1.3.6.1.4.1.3764.1.1.20.3 | ScalaragentTimeStamp | read-only | mandatory | The last time that the agent values have been updated. Universal time in seconds since UTC 1/1/70. |
| 1.3.6.1.4.1.3764.1.1.20.4 | ScalaragentGetTimeOut | read-only | mandatory | Suggested time out in milliseconds for how long an SNMP management application should wait while attempting to poll the SNMP agent. |
| 1.3.6.1.4.1.3764.1.1.20.5 | ScalaragentModifiers | read-only | mandatory | Agent functional modifiers, when set the modifier is active. Bit 3 => Agent in debug mode. All other bits are product specific. |
| 1.3.6.1.4.1.3764.1.1.20.6 | ScalaragentRefreshRate | read-only | mandatory | Rate in seconds at which the agent cached data is being updated. |
| 1.3.6.1.4.1.3764.1.1.30 | Nodecomponents | |||
| 1.3.6.1.4.1.3764.1.1.30.10 | TablecomponentTable | not-accessible | mandatory | General information about the system's components, including the unique identifiers. The structure this table is based on the Fibre Alliance MIB connUnitEntry. |
| 1.3.6.1.4.1.3764.1.1.30.10.1 | RowcomponentEntry | not-accessible | mandatory | A component entry containing objects for a particular component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.1 | ColumncomponentId | read-only | mandatory | The unique identification for this component among those within this proxy domain. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.2 | ColumncomponentType | read-only | mandatory | The type of this component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.3 | ColumncomponentDisplayName | read-only | mandatory | Name of this component for display purposes. Different OEMs may have different display names for the same ADIC product. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.4 | ColumncomponentInfo | read-write | mandatory | A display string containing information about this component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.5 | ColumncomponentLocation | read-only | mandatory | Location information for this component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.6 | ColumncomponentVendor | read-only | mandatory | Name vendor of this component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.7 | ColumncomponentSn | read-only | mandatory | The serial number for this component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.8 | ColumncomponentStatus | read-only | mandatory | Overall status of the component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.9 | ColumncomponentControl | read-write | mandatory | This object is used to control the addressed connUnit. NOTE: 'Cold Start' and 'Warm Start' are as defined in MIB II and are not meant to be a factory reset. re… |
| 1.3.6.1.4.1.3764.1.1.30.10.1.10 | ColumncomponentREDId | read-only | mandatory | Runtime Error Detection identifier for this power supply. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.11 | ColumncomponentFirmwareVersion | read-only | mandatory | Firmware version (or level) for this component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.12 | ColumncomponentGeoAddrAisle | read-only | mandatory | The aisle number where this component is located. A negative value indicates that an aisle number is not applicable to this component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.13 | ColumncomponentGeoAddrFrame | read-only | mandatory | The frame number where this component is located. A negative value indicates that a frame number is not applicable to this component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.14 | ColumncomponentGeoAddrRack | read-only | mandatory | The rack number where this component is located. A negative value indicates that a rack number is not applicable to this component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.15 | ColumncomponentGeoAddrChassis | read-only | mandatory | The chassis number where this component is located. A negative value indicates that a chassis number is not applicable to this component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.16 | ColumncomponentGeoAddrBlade | read-only | mandatory | The blade number within the network chasis where this component is located. A negative value indicates that a blade number is not applicable to this component. |
| 1.3.6.1.4.1.3764.1.1.30.10.1.17 | ColumncomponentIpAddress | read-only | mandatory | IP address of this component. If the component has no IP address, this object returns 0.0.0.0. The address may refer to an internal network not accessible to a… |
| 1.3.6.1.4.1.3764.1.1.100 | Nodesoftware | |||
| 1.3.6.1.4.1.3764.1.1.200 | Nodehardware | |||
| 1.3.6.1.4.1.3764.1.1.200.200 | NodepowerAndCooling | |||
| 1.3.6.1.4.1.3764.1.1.200.200.10 | TablepowerSupplyTable | not-accessible | optional | ** This table is optional ** Table of the power supplies. |
| 1.3.6.1.4.1.3764.1.1.200.200.10.1 | RowpowerSupplyEntry | not-accessible | optional | ** This entry object is optional ** Each entry contains the information for a specific power supply. |
| 1.3.6.1.4.1.3764.1.1.200.200.10.1.1 | ColumnpowerSupplyIndex | read-only | optional | ** This object is optional ** Index of this power supply within the component specified by componentId. |
| 1.3.6.1.4.1.3764.1.1.200.200.10.1.2 | ColumnpowerSupplyName | read-only | optional | ** This object is optional ** Display name of this power supply. |
| 1.3.6.1.4.1.3764.1.1.200.200.10.1.3 | ColumnpowerSupplyWattage | read-only | optional | ** This object is optional ** What is maximum power output of this power supply. Units are Watts. |
| 1.3.6.1.4.1.3764.1.1.200.200.10.1.4 | ColumnpowerSupplyType | read-only | optional | ** This object is optional ** DC or AC power supply? |
| 1.3.6.1.4.1.3764.1.1.200.200.10.1.5 | ColumnpowerSupplyREDId | read-only | optional | ** This object is optional ** Runtime Error Detection identifier for this power supply. |
| 1.3.6.1.4.1.3764.1.1.200.200.10.1.6 | ColumnpowerSupplyRatedVoltage | read-only | optional | ** This object is optional ** Rated output voltage in millivolts of this power supply. |
| 1.3.6.1.4.1.3764.1.1.200.200.10.1.7 | ColumnpowerSupplyLocation | read-only | optional | ** This object is optional ** Physical location of this power supply. |
| 1.3.6.1.4.1.3764.1.1.200.200.20 | TablevoltageSensorTable | not-accessible | optional | ** This table is optional ** Table of the voltage sensors. |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1 | RowvoltageSensorEntry | not-accessible | optional | ** This entry object is optional ** Each entry contains the information for a specific voltage sensor. |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.1 | ColumnvoltageSensorIndex | read-only | optional | ** This object is optional ** Index of this voltage sensor within the component specified by componentId. |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.2 | ColumnvoltageSensorName | read-only | optional | ** This object is optional ** Display name of this voltage sensor. |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.3 | ColumnvoltageSensorStatus | read-only | optional | ** This object is optional ** What is the state of this voltage sensor? Is the voltage in the nominal, warning or alarm region? |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.4 | ColumnvoltageSensorMillivolts | read-only | optional | ** This object is optional ** What is the voltage in millivolts of this voltage sensor? |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.5 | ColumnvoltageSensorType | read-only | optional | ** This object is optional ** DC or AC voltage sensor? |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.6 | ColumnvoltageSensorNominalLo | read-only | optional | ** This object is optional ** Lower voltage limit of the nominal state for this voltage sensor. Unit are millivolts. |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.7 | ColumnvoltageSensorNominalHi | read-only | optional | ** This object is optional ** Upper voltage limit of the nominal state for this voltage sensor. Unit are millivolts. |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.8 | ColumnvoltageSensorWarningLo | read-only | optional | ** This object is optional ** Lower voltage limit of the warning state for this voltage sensor. Unit are millivolts. If the voltage falls below this limit, the… |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.9 | ColumnvoltageSensorWarningHi | read-only | optional | ** This object is optional ** Upper voltage limit of the warning state for this voltage sensor. Unit are millivolts. If the voltage rises above this limit, the… |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.10 | ColumnvoltageSensorLocation | read-only | optional | ** This object is optional ** Physical location of the voltage sensor. |
| 1.3.6.1.4.1.3764.1.1.200.200.20.1.11 | ColumnvoltageSensorREDId | read-only | optional | ** This object is optional ** Runtime Error Detection identifier for this voltage sensor. |
| 1.3.6.1.4.1.3764.1.1.200.200.30 | TabletemperatureSensorTable | not-accessible | optional | ** This table is optional ** Table of the temperature sensors in each component. |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1 | RowtemperatureSensorEntry | not-accessible | optional | ** This entry object is optional ** Each entry contains the information for a specific sensor. |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1.1 | ColumntemperatureSensorIndex | read-only | optional | ** This object is optional ** Index of this temperatureSensor within the component specified by componentId. |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1.2 | ColumntemperatureSensorName | read-only | optional | ** This object is optional ** Display name of this temperatureSensor. |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1.3 | ColumntemperatureSensorStatus | read-only | optional | ** This object is optional ** What is the state of this temperatureSensor? Is the temperature in the nominal, warning or alarm region? |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1.4 | ColumntemperatureSensorDegreesCelsius | read-only | optional | ** This object is optional ** The temperature in degrees Celsuis for this temperature sensor. |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1.5 | ColumntemperatureSensorNominalLo | read-only | optional | ** This object is optional ** Lower temperature limit of the nominal state for this temperature sensor. Unit are degrees Celsius. |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1.6 | ColumntemperatureSensorNominalHi | read-only | optional | ** This object is optional ** Upper temperature limit of the nominal state for this temperature sensor. Unit are degrees Celsius. |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1.7 | ColumntemperatureSensorWarningLo | read-only | optional | ** This object is optional ** Lower temperature limit of the warning state for this temperature sensor. Unit are degrees Celsius. If the temperature falls belo… |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1.8 | ColumntemperatureSensorWarningHi | read-only | optional | ** This object is optional ** Upper temperature limit of the warning state for this temperature sensor. Unit are degrees Celsius. If the temperature rises abov… |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1.9 | ColumntemperatureSensorLocation | read-only | optional | ** This object is optional ** Physical location of this temperature sensor. |
| 1.3.6.1.4.1.3764.1.1.200.200.30.1.10 | ColumntemperatureSensorREDId | read-only | optional | ** This object is optional ** Runtime Error Detection identifier for this temperature sensor. |
| 1.3.6.1.4.1.3764.1.1.200.200.40 | TablecoolingFanTable | not-accessible | optional | ** This table is optional ** Table of cooling fans in the library. |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1 | RowcoolingFanEntry | not-accessible | optional | ** This entry object is optional ** Each entry contains the information for a specific cooling fan. |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1.1 | ColumncoolingFanIndex | read-only | optional | ** This object is optional ** Index of this cooling fan within the component specified by componentId. |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1.2 | ColumncoolingFanName | read-only | optional | ** This object is optional ** Display name of this coolingFan. |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1.3 | ColumncoolingFanStatus | read-only | optional | ** This object is optional ** Is the fan speed in the nominal, warning or alarm region? |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1.4 | ColumncoolingFanRPM | read-only | optional | ** This object is optional ** The fan speed in revolutions per minute. |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1.5 | ColumncoolingFanNominalLo | read-only | optional | ** This object is optional ** Lower fan speed limit of the nominal state for this fan. Units are RPM. |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1.6 | ColumncoolingFanNominalHi | read-only | optional | ** This object is optional ** Upper fan speed limit of the nominal state for this fan. Units are RPM. |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1.7 | ColumncoolingFanWarningLo | read-only | optional | ** This object is optional ** Lower fan speed limit of the warning state for this fan. Units are RPM. If the speed falls below this limit, the fan enters the a… |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1.8 | ColumncoolingFanWarningHi | read-only | optional | ** This object is optional ** Upper fan speed limit of the warning state for this fan. Units are RPM. If the speed rises above this limit, the fan enters the a… |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1.9 | ColumncoolingFanLocation | read-only | optional | ** This object is optional ** Physical location of this fan. |
| 1.3.6.1.4.1.3764.1.1.200.200.40.1.10 | ColumncoolingFanREDId | read-only | optional | ** This object is optional ** Runtime Error Detection identifier for this fan. |
| 1.3.6.1.4.1.3764.1.1.300 | Nodesml | |||
| 1.3.6.1.4.1.3764.1.1.400 | Nodenetwork | |||
| 1.3.6.1.4.1.3764.1.1.500 | Nodenotification | |||
| 1.3.6.1.4.1.3764.1.1.500 | NodestartupSequenceComplete | The component indicated by the value of componentId has successfully completed its startup sequence. | ||
| 1.3.6.1.4.1.3764.1.1.500.10 | TabletrapPayloadTable | not-accessible | mandatory | Defines objects common to all trap payloads. |
| 1.3.6.1.4.1.3764.1.1.500.10.1 | RowtrapPayloadEntry | not-accessible | mandatory | Each entry contains the information for a specific cooling fan. |
| 1.3.6.1.4.1.3764.1.1.500.10.1.1 | ColumntrapSequenceNumber | read-only | mandatory | |
| 1.3.6.1.4.1.3764.1.1.500.10.1.2 | ColumntrapSeverity | read-only | mandatory | |
| 1.3.6.1.4.1.3764.1.1.500.10.1.3 | ColumntrapSummaryText | read-only | mandatory | |
| 1.3.6.1.4.1.3764.1.1.500.10.1.4 | ColumntrapIntendedUsage | read-only | mandatory | The value of this qualifier aids the management application in determining how to respond to the trap. If the value is public(1), the information is intended t… |
| 1.3.6.1.4.1.3764.1.1.501 | NodeshutdownSequenceInitiated | The component indicated by the value of componentId has initiated its shutdown sequence. | ||
| 1.3.6.1.4.1.3764.1.1.502 | NodecomponentAdded | The component indicated by the value of componentId has been added to the library. | ||
| 1.3.6.1.4.1.3764.1.1.503 | NodecomponentRemoved | The component indicated by the value of componentId has been removed from the library. | ||
| 1.3.6.1.4.1.3764.1.1.504 | NodeproductLibraryClassChange | The product library class has changed. This occurs when connectivity hardware is added or removed. The payload contains the productLibraryClass before and afte… |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| AdicAgentStatus | INTEGER { other(1) , unknown(2) , ok(3) , non-critical(4) , critical(5) , non-recoverable(6) } | ||
| AdicComponentType | INTEGER{ mcb(1) , cmb(2) , ioBlade(3) , rcu(4) , networkChasis(5) , controlModule(6) , expansionModule(7) , powerSupply(8) } | ||
| AdicDateAndTime | OCTET STRING ( SIZE( 8 | 11) ) | ||
| AdicDoorStatus | INTEGER { open(1), closed(2), closedAndLocked(3), closedAndUnlocked(4), contollerFailed(5), notInstalled(6), noData(7) } | ||
| AdicDriveStatus | INTEGER { idle(1), loading(2), ejecting(3), inserted(4), removed(5), notInstalled(6), noData(7) } | ||
| AdicEnable | INTEGER { enabled(1) , disabled(2) } | ||
| AdicGlobalId | OCTET STRING (SIZE(8)) | ||
| AdicInterfaceType | INTEGER{ scsi(1) , fibreChannel(2) } | ||
| AdicOnlineStatus | INTEGER { online(1) , offline(2) , shutdown(3) } | ||
| AdicSensorStatus | INTEGER { nominal(1) , warningLow(2) , warningHigh(3) , alarmLow(4) , alarmHigh(5) , notInstalled(6) , noData(7) } | ||
| AdicTrapSeverity | INTEGER { emergency(1) , alarm(2) , warning(3) , notice(4) , informational(5) } | ||
| AdicVoltageType | INTEGER { dc(1) , ac(2) } | ||
| Boolean | INTEGER { true(1), false(2) } | ||
| RowStatus | INTEGER { active(1), notInService(2), notReady(3), createAndGo(4), createAndWait(5), destroy(6) } |