MIB Viewer

AIMOS

564 objects
The MIB is divided into ranges with different rights of access, in order not to grant any person access to the entire data. The protected main part of the information is located in the branch aimosObjects and can be accessed only after an authorising of the user, called login. The areas are accessible as follows: . The public area aimosPublic is accessible without any restrictions.It serves mainly to prepare the login procedure. . aimosLogin can be accessed only with special community names generated by the A.I.M.O.S. SNMP Agent. Here the login takes place. This authorising takes place via username and password. A valid user/password combination combined with a community name generated by the agent is called a session after the login has take place. The main part of the MIB (off aimosObjects downward) is permitted only within a valid session. . aimosObjects contains the objects of the managed network elements. This area is accessible only after a successful login (that is within a valid session) . aimosNotifications contains objects, which concern the alarm notifications. . aimosGroups and aimosCompliances satisfies SNMP requirements.
Imported Objects
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIenterprises Integer32 mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE TimeTicks Unsigned32 zeroDotZero
SNMPv2-TCDisplayString RowPointer TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.2.1.1Nodesystem
1.3.6.1.2.1.1NotificationthecurrentMasterID is an Unsigned32 value within the range from 1 to 9.999 used in order to uniquely identify Master Units, each containing up to 13 Racks. While each Ma…
1.3.6.1.2.1.1.1ScalarsysDescrread-onlycurrentA textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-syste…
1.3.6.1.2.1.1.2ScalarsysObjectIDread-onlycurrentThe vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtr…
1.3.6.1.2.1.1.3ScalarsysUpTimeread-onlycurrentThe time (in hundredths of a second) since the network management portion of the system was last re-initialized.
1.3.6.1.2.1.1.4ScalarsysContactread-writecurrentThe textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is k…
1.3.6.1.2.1.1.5ScalarsysNameread-writecurrentAn administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is th…
1.3.6.1.2.1.1.6ScalarsysLocationread-writecurrentThe physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.
1.3.6.1.4.1.6408IdentitymikomcurrentRoot of Andrew Wireless Systems GmbH
1.3.6.1.4.1.6408.201IdentityaimosThe MIB is divided into ranges with different rights of access, in order not to grant any person access to the entire data. The protected main part of the info…
1.3.6.1.4.1.6408.201.1IdentityaimosPubliccurrentBefore an user is able to login to the A.I.M.O.S. SNMP Agent, some preconditions must be fulfilled, which are located beneath aimosPublic and explained below. …
1.3.6.1.4.1.6408.201.1.1ScalaraimosSystemAvailabilityread-onlycurrentaimosSystemAvailability of type SystemAvailability gives information about system login possibility. The required value to be able to login is accessible(1). T…
1.3.6.1.4.1.6408.201.1.2ScalaraimosCommunityread-onlycurrentaimosCommunity of type Community issues a Community-Name required for the communication with the A.I.M.O.S. SNMP Agent. The Community public only allows access…
1.3.6.1.4.1.6408.201.1.3ScalaraimosCommunityLengthread-writecurrentaimosCommunityLength is an Unsigned32 value in the range of 1 to 40 which states the length of community names being generated on reading of aimosCommunity. Th…
1.3.6.1.4.1.6408.201.1.4ScalaraimosMinPasswordLengthread-writecurrentaimosMinPasswordLength is an Unsigned32 value in the range of 5 to 40 which states the requirement for the length of passwords. The provider is allowed to adju…
1.3.6.1.4.1.6408.201.2IdentityaimosLogincurrentThe aimosLogin branch carries the leafs for logging in as a specific user. As above-mentioned access to the branch aimosLogin is only permitted with SNMP commu…
1.3.6.1.4.1.6408.201.2.1ScalaraimosLoginUserNameread-writecurrentaimosLoginUserName of type UserName is provided to record the username for login purposes. The username is a predefined user account or a user account created …
1.3.6.1.4.1.6408.201.2.2ScalaraimosLoginPasswordread-writecurrentaimosLoginPassword of type PasswordString serves to record the password of the user. Here, the user must enter the password assigned to the user account by one…
1.3.6.1.4.1.6408.201.2.3ScalaraimosLoginStateread-writecurrentThe aimosLoginState of type LoginState is used in order to accomplish the login process, as its value is set to connected(1). If its value is set to disconnect…
1.3.6.1.4.1.6408.201.2.4ScalaraimosLoginOrgIDread-onlycurrentaimosLoginOrgID of type OrgID contains the organisation ID of the organisation of the user after successful login.
1.3.6.1.4.1.6408.201.2.5ScalaraimosLoginPhoneBookIDread-writecurrentAfter a successful login the AIMOS SNMP Agent attempts to recognize the SNMP Managers aimosLoginPhonebookID by means of its IP Address. In case the aimosPhoneB…
1.3.6.1.4.1.6408.201.3IdentityaimosObjectscurrentThe branch aimosObjects is accessible only after a successful login.
1.3.6.1.4.1.6408.201.3.1IdentityaimosSystemManagementcurrentIn this section, system-wide parameters are described. Only the provider is responsible for and allowed to change most of the contents of the listed MIB branch…
1.3.6.1.4.1.6408.201.3.1.1ScalaraimosMIBVersionread-onlycurrentThis object is a read-only value of type Version representing the version of the MIB file.
1.3.6.1.4.1.6408.201.3.1.2ScalaraimosAgentVersionread-onlycurrentThis object is a read-only value of type Version showing the software version of the A.I.M.O.S. SNMP Agent.
1.3.6.1.4.1.6408.201.3.1.3ScalaraimosOMCConnectorVersionread-onlycurrentThis object is a read-only value of type Version displaying the software version of the OMC Connector.
1.3.6.1.4.1.6408.201.3.1.4ScalaraimosTrapOIDaccessible-for-notifycurrentThis object of type OBJECT IDENTIFIER references the OID of the corresponding trap type listed in aimosNotifications, if aimosPhoneBookInterfaceType is set to …
1.3.6.1.4.1.6408.201.3.1.5ScalaraimosOMCSDNread-writecurrentThis object of type SDN is the system distinguished name of the OMC which is designated to uniquely identify this OMC within an organisation. E.g.: The third O…
1.3.6.1.4.1.6408.201.3.1.6ScalaraimosOMCNameread-writecurrentThis object of type Text with up to 40 characters is provided to assign a free definable name for the OMC, e.g. 'A.I.M.O.S. OMC - North'. It makes only sense i…
1.3.6.1.4.1.6408.201.3.1.7ScalaraimosTimeFormatread-writecurrentThis object of type TimeFormat determines of how date and time values of type VariableTime (e.g. aimosAlarmListEventTime) will be published by the SNMP Agent. …
1.3.6.1.4.1.6408.201.3.1.8ScalaraimosPasswordExpirationPeriodread-writecurrentThis object of type Unsigned32 within a range from 0 to 365 days decides the period of days after that passwords will expire. A value of 0 indicates, that the …
1.3.6.1.4.1.6408.201.3.1.9ScalaraimosPasswordReuseCounterread-writecurrentThis object of type Unsigned32 with a range from 1 to 255 denotes the number of distinguished passwords, that must be used, before a specific one can be repeat…
1.3.6.1.4.1.6408.201.3.1.10ScalaraimosPasswordStandardread-writecurrentThis object of type PasswordStandard determines if any numeric or special character is required in valid password creation. Existing passwords are not affected…
1.3.6.1.4.1.6408.201.3.1.11ScalaraimosSessionTimeoutread-writecurrentA Session is rejected after a certain time of inactivity. This object provides the means to adjust this period in minutes. Set this object to zero in order to …
1.3.6.1.4.1.6408.201.3.1.12ScalaraimosOMCConnectorAddressread-writecurrentThis object contains the IP address and the port that serves to access the OMC Connector. This information is required for creating Master Controllers. The val…
1.3.6.1.4.1.6408.201.3.1.13ScalaraimosCurrentTimeread-onlycurrentThis object of type VariableTime is used in heartbeat notifications and states the heartbeat notifications event time. This object also states the current time…
1.3.6.1.4.1.6408.201.3.2IdentityaimosUserManagementcurrentThe user management contains all access authorisation related data of organisations and its user accounts. Each organisation may have user accounts. An user ac…
1.3.6.1.4.1.6408.201.3.2.1TableaimosOrgTablenot-accessiblecurrentInformations about organizations. A organization is a company having a relationship with A.I.M.O.S.. Relationship can be one of the following: - manufacturer -…
1.3.6.1.4.1.6408.201.3.2.1.1RowaimosOrgEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.2.1.1.1ColumnaimosOrgIDread-onlycurrentThis object is a Mikom provided world-wide unique identification number of an organisation of type OrgID.
1.3.6.1.4.1.6408.201.3.2.1.1.2ColumnaimosOrgNameread-writecurrentThis object offers the possibility to designate the organisation mentioned in aimosOrgID. Set this value to 'delete' (without quotation marks) in order to dele…
1.3.6.1.4.1.6408.201.3.2.1.1.4ColumnaimosOrgTextread-writecurrentThis object gives each organisation the possibility to configure a piece of text.
1.3.6.1.4.1.6408.201.3.2.1.1.5ColumnaimosOrgLevelread-onlycurrentThis object of type OrgLevel denotes the role of the organisation. Possible values are manufacturer(0), provider(1) and telco(2).
1.3.6.1.4.1.6408.201.3.2.1.1.6ColumnaimosOrgMCCread-onlycurrentThis object of type MCC is the mobile country code of a TelCo organisation. Manufacturer and provider have the MCC of its country.
1.3.6.1.4.1.6408.201.3.2.1.1.7ColumnaimosOrgMNCread-onlycurrentThis object of type MNC is the mobile network code of a TelCo organisation. Manufacturer and provider have a MNC of 0 (zero).
1.3.6.1.4.1.6408.201.3.2.1.1.8ColumnaimosOrgActiveread-writecurrentThis object sets the activity state of an organisation. An organisation account is activated by writing true and deactivated by writing false to this object. U…
1.3.6.1.4.1.6408.201.3.2.1.1.9ColumnaimosOrgDNSeparatorread-writecurrentThis object of type DistinguishedNameSeparator separates the Distinguished Names into object type and object instance. E.g.: . 3GPP recommends equality mark (R…
1.3.6.1.4.1.6408.201.3.2.1.1.10ColumnaimosOrgDNConcatenatorread-writecurrentThis object of type DistinguishedNameHierarchySymbol divides System Distinguished Names in its parts, the Relative Distinguished Names. E.g.: . 3GPP recommends…
1.3.6.1.4.1.6408.201.3.2.1.1.11ColumnaimosOrgCCConcatenatorread-writecurrentThis object of type CableCodeConcatenator is used in aimosAlarmListCustomerCableInfo for concatenation of Cable Codes. Mikom default is a comma.
1.3.6.1.4.1.6408.201.3.2.1.1.12ColumnaimosOrgActiveWorkShiftIDread-writecurrentThis object denotes the active work shift for delegation of alarms. The description for aimosWorkShiftTable contains more about work shifts.
1.3.6.1.4.1.6408.201.3.2.1.1.13ColumnaimosOrgNextUserIDread-onlycurrentProvides the aimosUserID to be used in creating a new user account (aimosUserTable).
1.3.6.1.4.1.6408.201.3.2.1.1.14ColumnaimosOrgNextWorkShiftIDread-onlycurrentProvides the aimosWorkShiftID to be used in creating a new work shift (aimosWorkShiftTable).
1.3.6.1.4.1.6408.201.3.2.1.1.15ColumnaimosOrgNextAlarmRecipientListIDread-onlycurrentProvides the aimosAlarmRecipientListID to be used in creating a new alarm recipient list (aimosAlarmRecipientListTable).
1.3.6.1.4.1.6408.201.3.2.1.1.16ColumnaimosOrgNextPhoneBookIDread-onlycurrentProvides the aimosPhoneBookID to be used in creating a new phone book entry (aimosPhoneBookTable).
1.3.6.1.4.1.6408.201.3.2.2TableaimosUserTablenot-accessiblecurrentThis table holds user related data. A user is a employee of a organization having an login account. This table is indexed by aimosOrgID and aimosUserID. Nevert…
1.3.6.1.4.1.6408.201.3.2.2.1RowaimosUserEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.2.2.1.1ColumnaimosUserIDread-onlycurrentThis object is numbered consecutively. aimosOrgNextUserID tells you the value to be used in row/user creation.
1.3.6.1.4.1.6408.201.3.2.2.1.2ColumnaimosUserNameread-writecurrentThis object of type UserName hosts the users name. A user name can be used once in the OMC. Therefore it is advisable to prefix the user name with an organisat…
1.3.6.1.4.1.6408.201.3.2.2.1.3ColumnaimosUserPasswordread-writecurrentThis object of type PasswordString is the password for an user account required in order to login into the OMC. The default password is start. During the first…
1.3.6.1.4.1.6408.201.3.2.2.1.4ColumnaimosUserTextread-writecurrentThis object of type Text gives the possibility to configure a piece of text.
1.3.6.1.4.1.6408.201.3.2.2.1.5ColumnaimosUserRoleIDread-writecurrentWith this object a certain role is assigned to a user account. Thus, via the table aimosRoleRightTable the User is granted the rights that are assigned to this…
1.3.6.1.4.1.6408.201.3.2.2.1.6ColumnaimosUserActiveread-writecurrentThis object activates and deactivates an user account. If set to true the account is active and the user is able to log in, otherwise (false) no log in is poss…
1.3.6.1.4.1.6408.201.3.2.2.1.7ColumnaimosUserPasswordAgeread-onlycurrentThis object states the time when the password was most recently changed.
1.3.6.1.4.1.6408.201.3.2.3ScalaraimosNextRoleIDread-onlycurrentThis object is used in order to produce new roles within the aimosRoleTable. Its value has to be used as the identifier (aimosRoleID) of the new role.
1.3.6.1.4.1.6408.201.3.2.4TableaimosRoleTablenot-accessiblecurrentAccess control is made using roles. A role is a synonym for a certain combination of read and write access rights (AccessRight) to certain areas (RightArea). A…
1.3.6.1.4.1.6408.201.3.2.4.1RowaimosRoleEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.2.4.1.1ColumnaimosRoleIDread-onlycurrentThis object is numbered consecutively. Zero value is not allowed. aimosNextRoleID tells you the ID to be used in row creation.
1.3.6.1.4.1.6408.201.3.2.4.1.2ColumnaimosRoleNameread-writecurrentThis object contains a name for the role with up to 40 characters. The table entry is deleted by setting this value to delete.
1.3.6.1.4.1.6408.201.3.2.5TableaimosRoleRightTablenot-accessiblecurrentAccess control is made using roles. A role is a synonym for a certain combination of read and write access rights (AccessRight) to certain areas (RightArea). A…
1.3.6.1.4.1.6408.201.3.2.5.1RowaimosRoleRightEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.2.5.1.1ColumnaimosRoleRightArearead-onlycurrentThis object of type RightArea determines the right area arised from the controller software to be attached to a particular role identified by the index object …
1.3.6.1.4.1.6408.201.3.2.5.1.2ColumnaimosRoleRightAccessread-writecurrentThis object of type AccessRight determines whether read, write or no access to a specific RightArea has to be assigned to the affected role. Write access inclu…
1.3.6.1.4.1.6408.201.3.2.6ScalaraimosInitiallyMasterLoginUserNameread-writecurrentWhen a new Master Controller is created by making a new entry into the table aimosMasterUnitTable, the A.I.M.O.S. SNMP Agent requires a pre-setting for the obj…
1.3.6.1.4.1.6408.201.3.2.7ScalaraimosInitiallyMasterLoginPasswordread-writecurrentWhen a new Master Controller is created by making a new entry into the table aimosMasterUnitTable, the A.I.M.O.S. SNMP Agent requires a pre-setting for the obj…
1.3.6.1.4.1.6408.201.3.3IdentityaimosBandManagementcurrentBand Management is provided for allocation of radio frequencies to mobile network companies (TelCo's).
1.3.6.1.4.1.6408.201.3.3.1TableaimosBandTablenot-accessiblecurrentThis table, indexed by aimosBandID, configures the characteristics of each RF band. This set up is done by Mikom. Insert rows: must only be done by Mikom Delet…
1.3.6.1.4.1.6408.201.3.3.1.1RowaimosBandEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.3.1.1.1ColumnaimosBandIDread-onlycurrentThis object of type NetworkStandard determines the network standard of the band to which this entry belongs to.
1.3.6.1.4.1.6408.201.3.3.1.1.2ColumnaimosBandDLminread-onlycurrentThis object of type FrequencyRange is the lowest DL frequency (kHz) possible in a specific band.
1.3.6.1.4.1.6408.201.3.3.1.1.3ColumnaimosBandDLmaxread-onlycurrentThis object of type FrequencyRange is the highest DL frequency (kHz) possible in a specific band.
1.3.6.1.4.1.6408.201.3.3.1.1.4ColumnaimosBandULFrequencyGapread-onlycurrentThis object of type Unsigned32 with a range from 10000 to 95000 represents the frequency gap in kHz between UL and DL. Uplink frequency = downlink frequency - …
1.3.6.1.4.1.6408.201.3.3.1.1.5ColumnaimosBandULChannelGapread-onlycurrentThis object of type ARFCN represents the ARFCN gap between UL and DL. Uplink ARFCN = downlink ARFCN - gap.
1.3.6.1.4.1.6408.201.3.3.2TableaimosBandCalculationTablenot-accessiblecurrentFrequency calculation for any ARFCN can be done by the following formula: fDL(ARFCN) = fStart + fBandWidth * (ARFCN-aOffset) This table contains the informatio…
1.3.6.1.4.1.6408.201.3.3.2.1RowaimosBandCalculationEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.3.2.1.1ColumnaimosBandCalculationIDread-onlycurrentEnumerated consecutively.
1.3.6.1.4.1.6408.201.3.3.2.1.2ColumnaimosBandCalculationMinread-onlycurrentFirst ARFCN for wich the aimosBandCalculationFormula-leafs are valid.
1.3.6.1.4.1.6408.201.3.3.2.1.3ColumnaimosBandCalculationMaxread-onlycurrentLast ARFCN for wich the aimosBandCalculationFormula-leafs are valid.
1.3.6.1.4.1.6408.201.3.3.2.1.4ColumnaimosBandCalculationFormulaStartread-onlycurrentYou can calculate the frequency for any ARFCN with the following formula: fDL(ARFCN) = aimosBandCalculationFormulaStart + aimosBandCalculationFormulaGap * (ARF…
1.3.6.1.4.1.6408.201.3.3.2.1.5ColumnaimosBandCalculationFormulaBandWidthread-onlycurrentYou can calculate the frequency for any ARFCN with the following formula: fDL(ARFCN) = aimosBandCalculationFormulaStart + aimosBandCalculationFormulaGap * (ARF…
1.3.6.1.4.1.6408.201.3.3.2.1.6ColumnaimosBandCalculationFormulaOffsetread-onlycurrentYou can calculate the frequency for any ARFCN with the following formula: fDL(ARFCN) = aimosBandCalculationFormulaStart + aimosBandCalculationFormulaGap * (ARF…
1.3.6.1.4.1.6408.201.3.3.3TableaimosLicenseeTablenot-accessiblecurrentThis table is indexed by aimosOrgID, aimosBandID and aimosLicenseeFirstARFCN and shows information about frequencies licensed by Mobile Network Providers. Inse…
1.3.6.1.4.1.6408.201.3.3.3.1RowaimosLicenseeEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.3.3.1.1ColumnaimosLicenseeFirstARFCNread-onlycurrentThis object of type ARFCN is the first ARFCN of an licensed interval. The size of an ARFCN interval is specified by aimosLicenseeARFCNCount.
1.3.6.1.4.1.6408.201.3.3.3.1.2ColumnaimosLicenseeARFCNCountread-writecurrentthis object of type ARFCN represents the size of each ARFCN interval. The last ARFCN of an ARFCN interval is calculated by the following formula: last ARFCN = …
1.3.6.1.4.1.6408.201.3.3.4TableaimosFrequencyTablenot-accessiblecurrentThis table is indexed by aimosBandID and aimosFrequencyARFCN and tells you per radio frequency channel number its radio frequency and licensee (identified by i…
1.3.6.1.4.1.6408.201.3.3.4.1RowaimosFrequencyEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.3.4.1.1ColumnaimosFrequencyARFCNread-onlycurrentThis object of type ARFCN is the index of this table.
1.3.6.1.4.1.6408.201.3.3.4.1.2ColumnaimosFrequencyValueread-onlycurrentThis object of type FrequencyRange returns the frequency in kHz for aimosFrequencyARFCN.
1.3.6.1.4.1.6408.201.3.3.4.1.3ColumnaimosFrequencyOwnerread-onlycurrentThis object of type OrgID returns the organisation ID of the TelCo owning the license for this frequency/ARFCN.
1.3.6.1.4.1.6408.201.3.3.5TableaimosARFCNTablenot-accessiblecurrentThis table is indexed by aimosBandID and aimosARFCNFrequency and tells you per radio frequency its radio frequency channel number and licensee (identified by i…
1.3.6.1.4.1.6408.201.3.3.5.1RowaimosARFCNEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.3.5.1.1ColumnaimosARFCNFrequencyread-onlycurrentThis object of type FrequencyRange is the index (kHz) of this table.
1.3.6.1.4.1.6408.201.3.3.5.1.2ColumnaimosARFCNValueread-onlycurrentThis object of type ARFCN returns the ARFCN that corresponds to aimosARFCNFrequency.
1.3.6.1.4.1.6408.201.3.3.5.1.3ColumnaimosARFCNOwnerread-onlycurrentThis object of type OrgID returns the organisation ID of the TelCo owning the license for this ARFCN/frequency.
1.3.6.1.4.1.6408.201.3.4IdentityaimosAlarmManagementcurrentThis is a short introduction in order to help you understand how the A.I.M.O.S. SNMP Agent realises SNMP alarm forwarding. When the A.I.M.O.S. SNMP Agent is in…
1.3.6.1.4.1.6408.201.3.4.1ScalaraimosNextAlarmGroupIDread-onlycurrentThis object is needed in addition of alarm groups to the aimosAlarmGroupTable. Its value has to be used as the identifier (aimosAlarmGroupID) of the new alarm …
1.3.6.1.4.1.6408.201.3.4.2TableaimosAlarmGroupTablenot-accessiblecurrentThis table is indexed by aimosAlarmGroupID and lists the alarm groups available in the system. Alarm groups provides the means to collect alarms with similar c…
1.3.6.1.4.1.6408.201.3.4.2.1RowaimosAlarmGroupEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.4.2.1.1ColumnaimosAlarmGroupIDread-onlycurrentThis object is numbered consecutively. aimosNextAlarmGroupID tells you the ID to be used in row creation.
1.3.6.1.4.1.6408.201.3.4.2.1.2ColumnaimosAlarmGroupNameread-writecurrentThis object contains a name for the alarm group with up to 50 characters. Set this value to 'delete' (without quotation marks) in order to delete this table en…
1.3.6.1.4.1.6408.201.3.4.3TableaimosAlarmGroupAllowedOrgTablenot-accessiblecurrentThis table serves to specify the organisations that will be authorised to receive alarms of a certain alarm group. Organisations not listed in this table canno…
1.3.6.1.4.1.6408.201.3.4.3.1RowaimosAlarmGroupAllowedOrgEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.4.3.1.1ColumnaimosAlarmGroupAllowedOrgActiveread-writecurrentThis object is used for row creation and deletion. An existing table entry denotes, that the corresponding organisation is allowed to receive alarms collected …
1.3.6.1.4.1.6408.201.3.4.4TableaimosAlarmConfigTablenot-accessiblecurrentWith this table, indexed by aimosAlarmID, alarms can be configured. E.g. the Severity or the assignment to a certain alarm group can be specified here. Insert …
1.3.6.1.4.1.6408.201.3.4.4.1RowaimosAlarmConfigEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.4.4.1.1ColumnaimosAlarmIDread-onlycurrentThe aimosAlarmID of type AlarmID uniquely identifies the type of alarm.
1.3.6.1.4.1.6408.201.3.4.4.1.2ColumnaimosAlarmDescriptionread-onlycurrentThis object holds a short explanation of the type of alarm.
1.3.6.1.4.1.6408.201.3.4.4.1.3ColumnaimosAlarmEventTyperead-onlycurrentThe aimosAlarmEventType of type EventType categorises the alarm.
1.3.6.1.4.1.6408.201.3.4.4.1.4ColumnaimosAlarmDefaultSeverityread-writecurrentThis object of type Severity denotes the default severity of an alarm. Use the value indeterminate(0) in order to disable the alarm forwarding for this kind of…
1.3.6.1.4.1.6408.201.3.4.4.1.5ColumnaimosAlarmSeverityMinread-onlycurrentThis object of type Severity determines the at least allowed configurable severity in aimosAlarmDefaultSeverity and aimosAlarmSeverityRangeTable.
1.3.6.1.4.1.6408.201.3.4.4.1.6ColumnaimosAlarmAlarmGroupIDread-writecurrentThis object holds the Alarm Group assignment (aimosAlarmGroupID). Changes, which are made here, affect all organizations. That's why TelCo's are not allowed to…
1.3.6.1.4.1.6408.201.3.4.4.1.7ColumnaimosAlarmClearModeread-writecurrentThis object of type ClearMode informs you of how an alarm gets cleared. Changes, which are made here, affect all organizations. That's why TelCo's are not allo…
1.3.6.1.4.1.6408.201.3.4.5TableaimosAlarmSeverityRangeTablenot-accessibledeprecatedThis table holds organisation specific data of alarm severity configuration. Insert rows: set aimosAlarmSeverityRangeSeverity.<aimosOrgID>.<aimosAlarmID>. <aim…
1.3.6.1.4.1.6408.201.3.4.5.1RowaimosAlarmSeverityRangeEntrynot-accessibledeprecatedsee description for table entry...
1.3.6.1.4.1.6408.201.3.4.5.1.1ColumnaimosAlarmSeverityRangeMinValueread-onlydeprecatedLow value causing a defined severity.
1.3.6.1.4.1.6408.201.3.4.5.1.2ColumnaimosAlarmSeverityRangeMaxValueread-onlydeprecatedHigh value causing a defined severity.
1.3.6.1.4.1.6408.201.3.4.5.1.3ColumnaimosAlarmSeverityRangeSeverityread-writedeprecatedaimosAlarmSeverityRangeSeverity of type Severity holds the severity to be used in alarm notifications if the alarm value is within the range from aimosAlarmSev…
1.3.6.1.4.1.6408.201.3.4.6TableaimosWorkShiftTablenot-accessiblecurrentAlarm distribution depends on work shifts: . This table holds the available work shift ID's and names. . aimosOrgActiveWorkShiftID determines the active work s…
1.3.6.1.4.1.6408.201.3.4.6.1RowaimosWorkShiftEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.4.6.1.1ColumnaimosWorkShiftIDread-onlycurrentThis object is numbered consecutively. aimosOrgNextWorkShiftID tells you the ID to be used in row creation.
1.3.6.1.4.1.6408.201.3.4.6.1.2ColumnaimosWorkShiftNameread-writecurrentThis object contains a name for the work shift with up to 40 characters. Set this value to 'delete' (without quotation marks) in order to delete this table ent…
1.3.6.1.4.1.6408.201.3.4.6.1.3ColumnaimosWorkShiftHeartbeatIntervalread-writecurrentThis object is intended to specify the interval in minutes, after that the A.I.M.O.S. SNMP Agent will emit a heartbeat notification to one or more SNMP Manager…
1.3.6.1.4.1.6408.201.3.4.6.1.4ColumnaimosWorkShiftHeartbeatRecipientListread-writecurrentThis object is intended to specify the Alarm Recipient List which has to be used if the A.I.M.O.S. SNMP Agent emits heartbeat notifications. Each member of the…
1.3.6.1.4.1.6408.201.3.4.7TableaimosAlarmDistributionPlanTablenot-accessiblecurrentThis table, indexed by aimosOrgID, aimosAlarmGroupID and aimosWorkShiftID, holds the alarm recipient list to be used for sending alarms of a certain Alarm Grou…
1.3.6.1.4.1.6408.201.3.4.7.1RowaimosAlarmDistributionPlanEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.4.7.1.1ColumnaimosAlarmDistributionPlanRecipientListIDread-writecurrentThis objects value is the recipient lists ID (aimosAlarmRecipientListID) that will be bound up with the aimosAlarmGroupID and aimosWorkShiftID for aimosOrgID. …
1.3.6.1.4.1.6408.201.3.4.8TableaimosAlarmRecipientListTablenot-accessiblecurrentThis table holds the names and IDs of available alarm recipient lists for each organization. It is indexed by aimosOrgID and aimosAlarmRecipientListID. Insert …
1.3.6.1.4.1.6408.201.3.4.8.1RowaimosAlarmRecipientListEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.4.8.1.1ColumnaimosAlarmRecipientListIDread-onlycurrentThis object is numbered consecutively within one organisation. aimosOrgNextAlarmRecipientListID tells you the value to be used in alarm recipient list creation…
1.3.6.1.4.1.6408.201.3.4.8.1.2ColumnaimosAlarmRecipientListNameread-writecurrentThis object is just a name with a maximum length of 50 characters for the alarm recipient list. Set this value to 'delete' (without quotation marks) in order t…
1.3.6.1.4.1.6408.201.3.4.11TableaimosPhoneBookTablenot-accessiblecurrentThis table gives IP addresses and IP ports of alarm recipients (SNMP Manager) a name and classifies its communication type. Insert rows: set aimosPhoneBookAddr…
1.3.6.1.4.1.6408.201.3.4.11.1RowaimosPhoneBookEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.4.11.1.1ColumnaimosPhoneBookIDread-onlycurrentThis object is numbered consecutively within one organisation. aimosOrgNextPhoneBookID tells you the value to be used in phone book entry creation.
1.3.6.1.4.1.6408.201.3.4.11.1.2ColumnaimosPhoneBookNameread-writecurrentThis object of type PhoneBookEntry is a name for the phone book entry helping to disclose its identity. This name should be unique.
1.3.6.1.4.1.6408.201.3.4.11.1.3ColumnaimosPhoneBookAddressread-writecurrentThis object of type IPAddressAndPort hold the IP address and IP port number. The port number may be omitted in set requests, if the port number is the default …
1.3.6.1.4.1.6408.201.3.4.11.1.5ColumnaimosPhoneBookActiveread-writecurrentThis object is used in order to deactivate a phone book entry for a short period of time. Inactive phone book entries are excluded from alarm distribution even…
1.3.6.1.4.1.6408.201.3.4.11.1.6ColumnaimosPhoneBookLastNotificationIDread-writecurrentThis object denotes the notification ID used in the most recent trap for the specific SNMP Manager. The NotificationID of the next trap that is generated will …
1.3.6.1.4.1.6408.201.3.4.11.1.7ColumnaimosPhoneBookAlarmListResyncread-writecurrentThis object of type OperationMode is provided to give each SNMP Manager the ability to synchronise its alarm table. Setting this value to start(5) will start t…
1.3.6.1.4.1.6408.201.3.4.11.1.8ColumnaimosPhoneBookInterfaceTyperead-writecurrentThis object of type InterfaceType is provided in order to define the kind of alarm forwarding. Leave this object on its default value unless you want to force …
1.3.6.1.4.1.6408.201.3.4.11.1.9ColumnaimosPhoneBookAckCapabilityread-writecurrentThis object is provided in order to state the SNMP Managers ability to perform an acknowledgement. . If this object is set to true (default), then the SNMP Age…
1.3.6.1.4.1.6408.201.3.4.11.1.10ColumnaimosPhoneBookTimeDisplayFormatread-writecurrentThis object of type TimeDisplayFormat is provided in order to define ofhow date and time values (in objects of type VariableTime) inquired by an GET request or…
1.3.6.1.4.1.6408.201.3.4.11.1.11ColumnaimosPhoneBookGeographicPositionFormatread-writecurrentThis object defines the format to be used for objects with textual convention GPSPosition. These are as follows: . aimosAlarmListRaiseLatitude . aimosAlarmList…
1.3.6.1.4.1.6408.201.3.4.11.1.12ColumnaimosPhoneBookRecognitionTrapsread-writecurrentThis object provides means to state whether or not the SNMP Manager desires the SNMP Agent to sent a aimosAlarmRecognized trap in case an alarms recognition st…
1.3.6.1.4.1.6408.201.3.4.12TableaimosAlarmRecipientListMemberTablenot-accessiblecurrentThis table determines the members of a certain alarm recipient list. All active members of an Alarm Recipient List receive the alarm notifications assigned to …
1.3.6.1.4.1.6408.201.3.4.12.1RowaimosAlarmRecipientListMemberEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.4.12.1.1ColumnaimosAlarmRecipientListMemberActiveread-writecurrentThis object is used for row creation and deletion. Due to the way of row deletion there will never be an object in this table having a value of false. An exist…
1.3.6.1.4.1.6408.201.3.4.13TableaimosAlarmTrapTablenot-accessiblecurrentThis table is indexed by aimosOrgID, aimosAlarmTrapID and aimosAlarmListID and contains a list of all traps sent out by the agent to a specific SNMP Manager id…
1.3.6.1.4.1.6408.201.3.4.13.1RowaimosAlarmTrapEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.4.13.1.1ColumnaimosAlarmTrapIDread-onlycurrentThis object is an unique identifier for a trap on SNMP Agent side and is used in alarm acknowledgement. Even if its value is consecutive numbered on agent side…
1.3.6.1.4.1.6408.201.3.4.13.1.2ColumnaimosAlarmTrapNotificationIDread-onlycurrentThis object is incremented consecutively for each notification sent out to a particular SNMP Manager. Thus every SNMP Manager (identified by its phone book ent…
1.3.6.1.4.1.6408.201.3.4.13.1.3ColumnaimosAlarmTrapPhonebookIDread-onlycurrentThis object is the SNMP Managers aimosPhoneBookID to which the notification was directed to.
1.3.6.1.4.1.6408.201.3.4.13.1.4ColumnaimosAlarmTrapAcknowledgementStateread-writecurrentThis object of type AcknowledgementState states whether or not the alarm was acknowledged. It is the only writeable value in this table. Acknowledgement will b…
1.3.6.1.4.1.6408.201.3.4.13.1.5ColumnaimosAlarmTrapAcknowledgementUserread-onlycurrentThis object holds the user who has acknowledged the alarm. This object is empty if the alarm is not yet acknowledged.
1.3.6.1.4.1.6408.201.3.4.13.1.6ColumnaimosAlarmTrapAcknowledgementTimeread-onlycurrentThis object of type VariableTime holds the time of acknowledgement. This object is empty if the alarm is not yet acknowledged.
1.3.6.1.4.1.6408.201.3.4.14TableaimosAlarmListTablenot-accessiblecurrentThis table contains a list of active alarms. This table is indexed by aimosOrgID and aimosAlarmListID; i.e. the table is organisation specific and, thus has en…
1.3.6.1.4.1.6408.201.3.4.14.1RowaimosAlarmListEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.4.14.1.1ColumnaimosAlarmListIDread-onlycurrentThis object is the consecutive numbering of all alarm notifications of the A.I.M.O.S. SNMP Agent forwarded to any manager. A notification forwarded to more tha…
1.3.6.1.4.1.6408.201.3.4.14.1.2ColumnaimosAlarmListAlarmEventIDread-onlycurrentThis object's Unsigned32 value is incremented by one for each alarm notification except aimosAlarmChanged and aimosAlarmCleared. Alarm changed notifications an…
1.3.6.1.4.1.6408.201.3.4.14.1.3ColumnaimosAlarmListAlarmIDread-onlycurrentThis object of type AlarmID designates the alarm kind.
1.3.6.1.4.1.6408.201.3.4.14.1.4ColumnaimosAlarmListEventTyperead-onlycurrentThe Event Type categorises the alarm.
1.3.6.1.4.1.6408.201.3.4.14.1.5ColumnaimosAlarmListEventTimeread-onlycurrentThis object of type VariableTime states when the alarm condition appeared or (in the case of an aimosAlarmCleared notification) when the alarm condition is gon…
1.3.6.1.4.1.6408.201.3.4.14.1.6ColumnaimosAlarmListProbableCauseread-onlycurrentThis object of type ProbableCause defines further qualification of an alarm than aimosAlarmListEventType.
1.3.6.1.4.1.6408.201.3.4.14.1.7ColumnaimosAlarmListSpecificProblemread-onlycurrentThis object of type SpecificProblem is a fault specific value used in order to classify the fault situation. It provides further qualification of the alarm tha…
1.3.6.1.4.1.6408.201.3.4.14.1.8ColumnaimosAlarmListSeverityread-onlycurrentThis object of type Severity defines severity levels, which provide an indication of how it is perceived that the capability of the managed object has been aff…
1.3.6.1.4.1.6408.201.3.4.14.1.9ColumnaimosAlarmListTrendIndicationread-onlycurrentThis object of type TrendIndication specifies the current severity trend of the managed object.
1.3.6.1.4.1.6408.201.3.4.14.1.10ColumnaimosAlarmListAdditionalTextread-onlycurrentThis object allows a free form text description to be reported. It contains a formatted description of the alarm and, should the occasion arise, includes alarm…
1.3.6.1.4.1.6408.201.3.4.14.1.11ColumnaimosAlarmListSDNread-onlycurrentThe System Distinguished Name uniquely identifies the unit within the system controlled by the OMC.
1.3.6.1.4.1.6408.201.3.4.14.1.12ColumnaimosAlarmListTrapInforead-onlycurrentThis OID contains the Network Elements's TrapInfo
1.3.6.1.4.1.6408.201.3.4.14.1.13ColumnaimosAlarmListComponentNameread-onlycurrentThis OID contains the Network Elements's Component Name
1.3.6.1.4.1.6408.201.3.4.14.1.14ColumnaimosAlarmListLocationread-onlycurrentThis OID contains the Network Elements's Location
1.3.6.1.4.1.6408.201.3.4.14.1.15ColumnaimosAlarmListUniqueSystemIDread-onlycurrentThis OID contains the Network Elements's Unique System ID
1.3.6.1.4.1.6408.201.3.4.14.1.16ColumnaimosAlarmListClearReasonread-writecurrentThis OID gives information weather the alarm was cleared or not. If an alarm does not become automatically cleared (aimosAlarmClearMode is set to manualClear),…
1.3.6.1.4.1.6408.201.3.4.14.1.17ColumnaimosAlarmListClearTimeread-onlycurrentthis object of type VariableTime states the time of the event specified in aimosAlarmListClearReason.
1.3.6.1.4.1.6408.201.3.4.14.1.18ColumnaimosAlarmListRaiseLatituderead-onlycurrentthis object was introduced in V 2.6.0 and states the Network Elements Latitude to the time the alarm was raised.
1.3.6.1.4.1.6408.201.3.4.14.1.19ColumnaimosAlarmListRaiseLongituderead-onlycurrentthis object was introduced in V 2.6.0 and states the Network Elements Longitude to the time the alarm was raised.
1.3.6.1.4.1.6408.201.3.4.14.1.20ColumnaimosAlarmListClearLatituderead-onlycurrentthis object was introduced in V 2.6.0 and states the Network Elements Latitude to the time the alarm was cleared.
1.3.6.1.4.1.6408.201.3.4.14.1.21ColumnaimosAlarmListClearLongituderead-onlycurrentthis object was introduced in V 2.6.0 and states the Network Elements Longitude to the time the alarm was cleared.
1.3.6.1.4.1.6408.201.3.4.14.1.22ColumnaimosAlarmListRecognitionStateread-writecurrentThis object of type RecognitionState states whether or not the alarm has been recognized. Together with aimosAlarmListClearReason these objects are the only wr…
1.3.6.1.4.1.6408.201.3.4.14.1.23ColumnaimosAlarmListRecognitionUserread-onlycurrentThis object indicates the user who has recognized the alarm. This object is empty if the alarm is not recognized at all.
1.3.6.1.4.1.6408.201.3.4.14.1.24ColumnaimosAlarmListRecognitionTimeread-onlycurrentThis object of type VariableTime holds the time of recognition. This object is empty if the alarm is not recognized at all.
1.3.6.1.4.1.6408.201.3.4.15TableaimosAlarmLogTablenot-accessiblecurrentThis table is indexed by aimosOrgID, aimosAlarmTrapID and aimosAlarmListID and contains the list of cleared and acknowledged alarms. The data is the content of…
1.3.6.1.4.1.6408.201.3.4.15.1RowaimosAlarmLogEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.4.15.1.1ColumnaimosAlarmLogPhoneBookIDread-onlycurrentSee corresponding description in aimosAlarmTrapTable.
1.3.6.1.4.1.6408.201.3.4.15.1.2ColumnaimosAlarmLogNotificationIDread-onlycurrentSee corresponding description in aimosAlarmTrapTable.
1.3.6.1.4.1.6408.201.3.4.15.1.3ColumnaimosAlarmLogAlarmEventIDread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.4ColumnaimosAlarmLogAlarmIDread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.5ColumnaimosAlarmLogEventTyperead-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.6ColumnaimosAlarmLogEventTimeread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.7ColumnaimosAlarmLogProbableCauseread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.8ColumnaimosAlarmLogSpecificProblemread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.9ColumnaimosAlarmLogSeverityread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.10ColumnaimosAlarmLogTrendIndicationread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.11ColumnaimosAlarmLogAdditionalTextread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.12ColumnaimosAlarmLogSDNread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.13ColumnaimosAlarmLogTrapInforead-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.14ColumnaimosAlarmLogComponentNameread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.15ColumnaimosAlarmLogLocationread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.16ColumnaimosAlarmLogUniqueSystemIDread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.17ColumnaimosAlarmLogAcknowledgementUserread-onlycurrentSee corresponding description in aimosAlarmTrapTable.
1.3.6.1.4.1.6408.201.3.4.15.1.18ColumnaimosAlarmLogAcknowledgementTimeread-onlycurrentSee corresponding description in aimosAlarmTrapTable.
1.3.6.1.4.1.6408.201.3.4.15.1.19ColumnaimosAlarmLogClearReasonread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.20ColumnaimosAlarmLogClearTimeread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.21ColumnaimosAlarmLogClearTrapIDread-onlycurrentSee corresponding description in aimosAlarmTrapTable.
1.3.6.1.4.1.6408.201.3.4.15.1.22ColumnaimosAlarmLogClearNotificationIDread-onlycurrentSee corresponding description in aimosAlarmTrapTable.
1.3.6.1.4.1.6408.201.3.4.15.1.23ColumnaimosAlarmLogClearAcknowledgementUserread-onlycurrentSee corresponding description in aimosAlarmTrapTable.
1.3.6.1.4.1.6408.201.3.4.15.1.24ColumnaimosAlarmLogClearAcknowledgementTimeread-onlycurrentSee corresponding description in aimosAlarmTrapTable.
1.3.6.1.4.1.6408.201.3.4.15.1.25ColumnaimosAlarmLogRaiseLatituderead-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.26ColumnaimosAlarmLogRaiseLongituderead-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.27ColumnaimosAlarmLogClearLatituderead-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.28ColumnaimosAlarmLogClearLongituderead-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.29ColumnaimosAlarmLogRecognitionStateread-writecurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.30ColumnaimosAlarmLogRecognitionUserread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.15.1.31ColumnaimosAlarmLogRecognitionTimeread-onlycurrentSee corresponding description in aimosAlarmListTable.
1.3.6.1.4.1.6408.201.3.4.16ScalaraimosAlarmForwardingTyperead-writecurrentThis object of type AlarmForwardingType specifies if and in what way, alarm forwarding is to be carried out: . If this object is set to disabled(0), there is n…
1.3.6.1.4.1.6408.201.3.4.17ScalaraimosAlarmAckExpectIntervalread-writecurrentAfter having emitted an alarm notification, the SNMP Agent expects an acknowledgement within a certain interval. This period of time is adjustable by means of …
1.3.6.1.4.1.6408.201.3.4.18ScalaraimosAlarmListRebuildread-writecurrentATTENTION: Setting this objects value to start(5) will initiate an Alarm List Rebuild process. During this process ALL ALARM INFORMATION WILL BE DELETED ! The …
1.3.6.1.4.1.6408.201.3.4.19ScalaraimosAlarmListResyncread-writecurrentThis object of type OperationMode is provided to give each SNMP Manager the ability to synchronise its alarm table. Setting this value to start(5) will start t…
1.3.6.1.4.1.6408.201.3.5IdentityaimosUnitManagementcurrentThis area comprises all objects dealing with unit management. This introduction provides an explanation of its basic structures. For each unit type there is on…
1.3.6.1.4.1.6408.201.3.5.1ScalaraimosNextMasterIDread-onlycurrentThis object of type MasterID is used in order to create new Master Unit table entries. Its value has to be used as the identifier (aimosMasterID) of the new Ma…
1.3.6.1.4.1.6408.201.3.5.2TableaimosMasterUnitTablenot-accessiblecurrentThis table contains hardware revision independent information's about Master Units including its Master Controller. A Master Unit consists of up to 127 Remote …
1.3.6.1.4.1.6408.201.3.5.2.1RowaimosMasterUnitEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.2.1.1ColumnaimosMasterIDread-onlycurrentThis object of type MasterID uniquely identifies the Master Controller within the OMC. aimosNextMasterID tells you the value to be used in row creation.
1.3.6.1.4.1.6408.201.3.5.2.1.2ColumnaimosMasterRDNread-onlycurrentThis object of type RDN shows the Relative Distinguished Name which consists of the object type and an object instance divided by the Distinguished Name Separa…
1.3.6.1.4.1.6408.201.3.5.2.1.3ColumnaimosMasterSDNread-onlycurrentThis object of type SDN shows the System Distinguished Name which consists of a chaining of all RDN's all the way down from the OMC point of view to the desire…
1.3.6.1.4.1.6408.201.3.5.2.1.4ColumnaimosMasterIdentNoread-onlycurrentThis object of type IdentNo carries the Mikom Identification Number of the Master Controller.
1.3.6.1.4.1.6408.201.3.5.2.1.5ColumnaimosMasterSerialNoread-onlycurrentThis object of type SerialNo represents the Mikom Serial Number of the Master Controller.
1.3.6.1.4.1.6408.201.3.5.2.1.6ColumnaimosMasterTrapInforead-writecurrentThis object of type Text lays down additional information to be provided with each notification sent to any SNMP Manager. The SNMP Agent makes this information…
1.3.6.1.4.1.6408.201.3.5.2.1.7ColumnaimosMasterLocationread-writecurrentThis object of type Text is a textual description of the place, where the Master Unit is located.
1.3.6.1.4.1.6408.201.3.5.2.1.8ColumnaimosMasterAnyTextread-writecurrentThis object of type Text gives the ability to store any unit related text.
1.3.6.1.4.1.6408.201.3.5.2.1.9ColumnaimosMasterMapXYread-writecurrentThis object of type Coordinates carries co-ordinates of Master Unit location.
1.3.6.1.4.1.6408.201.3.5.2.1.10ColumnaimosMasterOIDread-onlycurrentThis object of type RowPointer provides the OID where to find hardware specific information. In the first release of A.I.M.O.S. this object will point to the a…
1.3.6.1.4.1.6408.201.3.5.2.1.11ColumnaimosMasterAddressread-writecurrentThis object of type IPAddressAndPort provides the Master Controllers IP address and port number. When a new Master Controller was integrated into the network b…
1.3.6.1.4.1.6408.201.3.5.2.1.12ColumnaimosMasterStateread-writecurrentThis object of type MasterState indicates the state of the Master Controller's system integration and should always be properlySet(7). Immediately after the Ma…
1.3.6.1.4.1.6408.201.3.5.2.1.13ColumnaimosMasterGUIDread-onlycurrentThis object of type GUID is a globally unambiguous name for the Master Controller. This is not redundant with regard to the aimosMasterID, for if a Master Cont…
1.3.6.1.4.1.6408.201.3.5.2.1.14ColumnaimosMasterLoginUserNameread-writecurrentThis object of type UserName is the user name (max. length is 20 characters) used by the OMC for establishing a login with the Master Controller. When a new ta…
1.3.6.1.4.1.6408.201.3.5.2.1.15ColumnaimosMasterLoginPasswordread-writecurrentThis object of type ControllerPassword contains the password for establishing a login with the Master Controller. The password can be read but the A.I.M.O.S. S…
1.3.6.1.4.1.6408.201.3.5.3TableaimosSubRackTablenot-accessiblecurrentThis table contains hardware revision independent information's about the SubRack Master Unit. Insert rows: must only be done by system Delete rows: must only …
1.3.6.1.4.1.6408.201.3.5.3.1RowaimosSubRackEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.3.1.1ColumnaimosSubRackIDread-onlycurrentThis object of type SubRackID uniquely identifies the Sub Rack Master Unit within its parent, a Master Unit.
1.3.6.1.4.1.6408.201.3.5.3.1.2ColumnaimosSubRackRDNread-onlycurrentThis object of type RDN shows the Relative Distinguished Name which consists of the object type and an object instance divided by the Distinguished Name Separa…
1.3.6.1.4.1.6408.201.3.5.3.1.3ColumnaimosSubRackSDNread-onlycurrentThis object of type SDN shows the System Distinguished Name which consists of a chaining of all RDN's all the way down from the OMC point of view to the desire…
1.3.6.1.4.1.6408.201.3.5.3.1.4ColumnaimosSubRackIdentNoread-onlycurrentThis object of type IdentNo carries the Mikom Identification Number of the Sub Rack Master Unit.
1.3.6.1.4.1.6408.201.3.5.3.1.5ColumnaimosSubRackSerialNoread-onlycurrentThis object of type SerialNo represents the Mikom Serial Number of the Sub Rack Mater Unit.
1.3.6.1.4.1.6408.201.3.5.3.1.6ColumnaimosSubRackTrapInforead-writecurrentThis object of type Text lays down additional information to be provided with each notification sent to any SNMP Manager. The SNMP Agent makes this information…
1.3.6.1.4.1.6408.201.3.5.3.1.7ColumnaimosSubRackLocationread-writecurrentThis object of type Text is a textual description of the place, where the Sub Rack Master Unit is located.
1.3.6.1.4.1.6408.201.3.5.3.1.8ColumnaimosSubRackAnyTextread-writecurrentThis object of type Text gives the ability to store any unit related text.
1.3.6.1.4.1.6408.201.3.5.3.1.9ColumnaimosSubRackMapXYread-writecurrentThis object of type Coordinates carries co-ordinates of Sub Rack Master Unit location.
1.3.6.1.4.1.6408.201.3.5.3.1.10ColumnaimosSubRackOIDread-onlycurrentThis object of type RowPointer provides the OID where to find hardware specific information. In the first release of A.I.M.O.S. this object will point to the a…
1.3.6.1.4.1.6408.201.3.5.4TableaimosRemoteUnitTablenot-accessiblecurrentThis table contains hardware revision independent information's about Remote Units. Insert rows: must only be done by system Delete rows: must only be done by …
1.3.6.1.4.1.6408.201.3.5.4.1RowaimosRemoteUnitEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.4.1.1ColumnaimosRemoteIDread-onlycurrentThis object of type RemoteID uniquely identifies the Remote Unit within the connected Sub Rack Master Unit.
1.3.6.1.4.1.6408.201.3.5.4.1.2ColumnaimosRemoteRDNread-onlycurrentThis object of type RDN shows the Relative Distinguished Name which consists of the object type and an object instance divided by the Distinguished Name Separa…
1.3.6.1.4.1.6408.201.3.5.4.1.3ColumnaimosRemoteSDNread-onlycurrentThis object of type SDN shows the System Distinguished Name which consists of a chaining of all RDN's all the way down from the OMC point of view to the desire…
1.3.6.1.4.1.6408.201.3.5.4.1.4ColumnaimosRemoteIdentNoread-onlycurrentThis object of type IdentNo carries the Mikom Identification Number of the Remote Unit.
1.3.6.1.4.1.6408.201.3.5.4.1.5ColumnaimosRemoteSerialNoread-onlycurrentThis object of type SerialNo represents the Mikom Serial Number of the Remote Unit.
1.3.6.1.4.1.6408.201.3.5.4.1.6ColumnaimosRemoteTrapInforead-writecurrentThis object of type Text lays down additional information to be provided with each notification sent to any SNMP Manager. The SNMP Agent makes this information…
1.3.6.1.4.1.6408.201.3.5.4.1.7ColumnaimosRemoteLocationread-writecurrentThis object of type Text is a textual description of the place, where the Remote Unit is located.
1.3.6.1.4.1.6408.201.3.5.4.1.8ColumnaimosRemoteAnyTextread-writecurrentThis object of type Text gives the ability to store any unit related text.
1.3.6.1.4.1.6408.201.3.5.4.1.9ColumnaimosRemoteMapXYread-writecurrentThis object of type Coordinates carries co-ordinates of Remote Unit location.
1.3.6.1.4.1.6408.201.3.5.4.1.10ColumnaimosRemoteOIDread-onlycurrentThis object of type RowPointer provides the OID where to find hardware specific information. In the first release of A.I.M.O.S. this object will point to the a…
1.3.6.1.4.1.6408.201.3.5.5TableaimosGSMNSOTablenot-accessiblecurrentThis table contains hardware revision independent information's about GSM NSO's. Insert rows: must only be done by system Delete rows: must only be done by sys…
1.3.6.1.4.1.6408.201.3.5.5.1RowaimosGSMNSOEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.5.1.1ColumnaimosGSMNSOIDread-onlycurrentThis object of type NSOID uniquely identifies the GSM NSO within the connected Remote Unit.
1.3.6.1.4.1.6408.201.3.5.5.1.2ColumnaimosGSMNSORDNread-onlycurrentThis object of type RDN shows the Relative Distinguished Name which consists of the object type and an object instance divided by the Distinguished Name Separa…
1.3.6.1.4.1.6408.201.3.5.5.1.3ColumnaimosGSMNSOSDNread-onlycurrentThis object of type SDN shows the System Distinguished Name which consists of a chaining of all RDN's all the way down from the OMC point of view to the desire…
1.3.6.1.4.1.6408.201.3.5.5.1.4ColumnaimosGSMNSOIdentNoread-onlycurrentThis object of type IdentNo carries the Mikom Identification Number of the GSM NSO.
1.3.6.1.4.1.6408.201.3.5.5.1.5ColumnaimosGSMNSOSerialNoread-onlycurrentThis object of type SerialNo represents the Mikom Serial Number of the GSM NSO.
1.3.6.1.4.1.6408.201.3.5.5.1.6ColumnaimosGSMNSOTrapInforead-writecurrentThis object of type Text lays down additional information to be provided with each notification sent to any SNMP Manager. Since the GSM NSO is located in the R…
1.3.6.1.4.1.6408.201.3.5.5.1.7ColumnaimosGSMNSOLocationread-writecurrentThis object of type Text is a textual description of the place, where the GSM NSO is located. Since the GSM NSO is located in the Remote Unit, this object's va…
1.3.6.1.4.1.6408.201.3.5.5.1.8ColumnaimosGSMNSOAnyTextread-writecurrentThis object of type Text gives the ability to store any unit related text.
1.3.6.1.4.1.6408.201.3.5.5.1.9ColumnaimosGSMNSOMapXYread-writecurrentThis object of type Coordinates carries co-ordinates of GSM NSO location.
1.3.6.1.4.1.6408.201.3.5.5.1.10ColumnaimosGSMNSOOIDread-onlycurrentThis object of type RowPointer provides the OID where to find hardware specific information. In the first release of A.I.M.O.S. this object will point to the a…
1.3.6.1.4.1.6408.201.3.5.5.1.11ColumnaimosGSMNSOOIDDataread-onlycurrentThis object of type RowPointer shows the OID, which provides measurement data of GSM NSO. In the first release of A.I.M.O.S. this object will point to directly…
1.3.6.1.4.1.6408.201.3.5.6TableaimosUMTSNSOTablenot-accessiblecurrentThis table contains hardware revision independent information's about UMTS NSO's. Insert rows: must only be done by system Delete rows: must only be done by sy…
1.3.6.1.4.1.6408.201.3.5.6.1RowaimosUMTSNSOEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.6.1.1ColumnaimosUMTSNSOIDread-onlycurrentThis object of type NSOID uniquely identifies the UMTS NSO within the connected Remote Unit.
1.3.6.1.4.1.6408.201.3.5.6.1.2ColumnaimosUMTSNSORDNread-onlycurrentThis object of type RDN shows the Relative Distinguished Name which consists of the object type and an object instance divided by the Distinguished Name Separa…
1.3.6.1.4.1.6408.201.3.5.6.1.3ColumnaimosUMTSNSOSDNread-onlycurrentThis object of type SDN shows the System Distinguished Name which consists of a chaining of all RDN's all the way down from the OMC point of view to the desire…
1.3.6.1.4.1.6408.201.3.5.6.1.4ColumnaimosUMTSNSOIdentNoread-onlycurrentThis object of type IdentNo carries the Mikom Identification Number of the UMTS NSO.
1.3.6.1.4.1.6408.201.3.5.6.1.5ColumnaimosUMTSNSOSerialNoread-onlycurrentThis object of type SerialNo represents the Mikom Serial Number of the UMTS NSO.
1.3.6.1.4.1.6408.201.3.5.6.1.6ColumnaimosUMTSNSOTrapInforead-writecurrentThis object of type Text lays down additional information to be provided with each notification sent to any SNMP Manager. Since the UMTS NSO is located in the …
1.3.6.1.4.1.6408.201.3.5.6.1.7ColumnaimosUMTSNSOLocationread-writecurrentThis object of type Text is a textual description of the place, where the UMTS NSO is located. Since the UMTS NSO is located in the Remote Unit, this object's …
1.3.6.1.4.1.6408.201.3.5.6.1.8ColumnaimosUMTSNSOAnyTextread-writecurrentThis object of type Text gives the ability to store any unit related text.
1.3.6.1.4.1.6408.201.3.5.6.1.9ColumnaimosUMTSNSOMapXYread-writecurrentThis object of type Coordinates carries co-ordinates of UMTS NSO location.
1.3.6.1.4.1.6408.201.3.5.6.1.10ColumnaimosUMTSNSOOIDread-onlycurrentThis object of type RowPointer provides the OID where to find hardware specific information. In the first release of A.I.M.O.S. this object will point to the a…
1.3.6.1.4.1.6408.201.3.5.6.1.11ColumnaimosUMTSNSOOIDDataread-onlycurrentThis object of type RowPointer shows the OID, which provides measurement data of UMTS NSO. In the first release of A.I.M.O.S. this object will point to directl…
1.3.6.1.4.1.6408.201.3.5.7ScalaraimosNextCableIDread-onlycurrentThis object of type CableID has to be used in order to create new entries in aimosCableTable. The value has to be used as the identifier for new entries.
1.3.6.1.4.1.6408.201.3.5.8TableaimosCableTablenot-accessiblecurrentThis table contains information's about fibre-optic cables used in interconnection between Remote Units and SubRack Master Units. This information is transmitt…
1.3.6.1.4.1.6408.201.3.5.8.1RowaimosCableEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.8.1.1ColumnaimosCableIDread-onlycurrentThis object of type CableID is an unique identifier for cable table entries. aimosNextCableID tells you the value to be used in cable table entry creation.
1.3.6.1.4.1.6408.201.3.5.8.1.2ColumnaimosCableCoderead-writecurrentThis value of type CableCode holds the textual identification / representation of a specific cable. Set this value to 'delete' (without quotation marks) in ord…
1.3.6.1.4.1.6408.201.3.5.8.1.3ColumnaimosCableTrapInforead-writecurrentIn aimosCableTrapInfo of type Text a freely definable identification can be entered, by which the cable can be identified. This identifier is transmitted with …
1.3.6.1.4.1.6408.201.3.5.8.1.4ColumnaimosCableLocationread-writecurrentThis object of type Text is a textual description of the place, where the cable is located. Changes, which are made here, affect all organizations. That's why …
1.3.6.1.4.1.6408.201.3.5.8.1.5ColumnaimosCableAnyTextread-writecurrentThis object of type Text gives the ability to store any unit related text. Changes, which are made here, affect all organizations. That's why TelCo's are not a…
1.3.6.1.4.1.6408.201.3.5.9TableaimosCableUsageTablenot-accessiblecurrentThis table contains information as to which cable or even which cores of a cable were used to connect a certain Sub Rack Master Unit to a certain Remote Unit. …
1.3.6.1.4.1.6408.201.3.5.9.1RowaimosCableUsageEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.9.1.1ColumnaimosCableUsageRemoteUnitReferenceread-onlycurrentThis object is of type UnitReference and identifies the Remote Unit to which the current table entry does refer.
1.3.6.1.4.1.6408.201.3.5.9.1.2ColumnaimosCableUsageIDread-onlycurrentThis object determines the sequence of cables used in order to connect the Sub Rack Master Unit with a specific Remote Unit. The cable directly connected to th…
1.3.6.1.4.1.6408.201.3.5.9.1.3ColumnaimosCableUsageCableIDread-writecurrentThis object of type CableID shows which cable was used to connect the Remote Unit identified by aimosCableUsageRemoteUnitReference with the SubRack Master Unit…
1.3.6.1.4.1.6408.201.3.5.9.1.4ColumnaimosCableUsageFibreCoderead-writecurrentThis object of type CableCode can be used to identify the cores used in the cable. This identification can be taken over into the object aimosAlarmListCustomer…
1.3.6.1.4.1.6408.201.3.5.9.1.5ColumnaimosCableUsageAlternativeTrapInforead-writecurrentIn aimosCableUsageAlternativeTrapInfo of type Text a freely definable identification for identifying cable and used core can be entered. This identification is…
1.3.6.1.4.1.6408.201.3.5.13TableaimosMasterUnitV1Tablenot-accessiblecurrentThis table contains information's about Master Units with hardware revision 1. Insert rows: must only be done by system Delete rows: must only be done by system
1.3.6.1.4.1.6408.201.3.5.13.1RowaimosMasterUnitV1Entrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.13.1.1ColumnaimosMasterV1UnitReferenceread-onlycurrentThis object of type UnitReference is the first index of this table. It unambiguously identifies the unit, independent of its kind (Master Unit, Sub Rack Master…
1.3.6.1.4.1.6408.201.3.5.13.1.2ColumnaimosMasterV1ValueSourceread-onlycurrentThis object of type ValueSource is the second index in this table. It indicates, which value is to be addressed (actual, cached or desired value): . actual : A…
1.3.6.1.4.1.6408.201.3.5.13.1.3ColumnaimosMasterV1HeartbeatIntervalread-writecurrentAlternatively to a regular polling of the Master Controllers by an SNMP Manager, the Master Controller is capable of sending a regular 'I'm-alive-message' to t…
1.3.6.1.4.1.6408.201.3.5.13.1.4ColumnaimosMasterV1HeartbeatOvertimeread-writecurrentThis object of type WeekMinutes offers the possibility to set a certain waiting time. This is required to compensate the differing latency periods of the Maste…
1.3.6.1.4.1.6408.201.3.5.13.1.5ColumnaimosMasterV1HeartbeatTimeread-onlycurrentThis object of type VariableTime provides the time when the Master Controller sent the last life sign. It does not make sense to read this value to an instance…
1.3.6.1.4.1.6408.201.3.5.14TableaimosSubRackV1Tablenot-accessiblecurrentThis table contains information's about SubRack Master Units with hardware revision 1. Insert rows: must only be done by system Delete rows: must only be done …
1.3.6.1.4.1.6408.201.3.5.14.1RowaimosSubRackV1Entrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.14.1.1ColumnaimosSubRackV1UnitReferenceread-onlycurrentThis object of type UnitReference is the first index of this table. It unambiguously identifies the unit, independent of its kind (Master Unit, Sub Rack Master…
1.3.6.1.4.1.6408.201.3.5.14.1.2ColumnaimosSubRackV1ValueSourceread-onlycurrentThis object of type ValueSource is the second index in this table. It indicates, which value is to be addressed (actual, cached or desired value): . actual : A…
1.3.6.1.4.1.6408.201.3.5.14.1.3ColumnaimosSubRackV1AttenuationAgeread-writecurrentIn both the uplink (UL) and the downlink (DL) path for each of the three bands supported by the three amplifiers (1 to 3), the attenuation of the corresponding…
1.3.6.1.4.1.6408.201.3.5.14.1.4ColumnaimosSubRackV1AttenuationAmp1DLread-writecurrentAttenuation on amplifier 1 downlink. The object aimosSubRackV1AttenuationAge indicates the age of this information. Changes, which are made here, affect the ha…
1.3.6.1.4.1.6408.201.3.5.14.1.5ColumnaimosSubRackV1AttenuationAmp1ULread-writecurrentAttenuation on amplifier 1 uplink. The object aimosSubRackV1AttenuationAge indicates the age of this information. Changes, which are made here, affect the hard…
1.3.6.1.4.1.6408.201.3.5.14.1.6ColumnaimosSubRackV1AttenuationAmp2DLread-writecurrentAttenuation on amplifier 2 downlink. The object aimosSubRackV1AttenuationAge indicates the age of this information. Changes, which are made here, affect the ha…
1.3.6.1.4.1.6408.201.3.5.14.1.7ColumnaimosSubRackV1AttenuationAmp2ULread-writecurrentAttenuation on amplifier 2 uplink. The object aimosSubRackV1AttenuationAge indicates the age of this information. Changes, which are made here, affect the hard…
1.3.6.1.4.1.6408.201.3.5.14.1.8ColumnaimosSubRackV1AttenuationAmp3DLread-writecurrentAttenuation on amplifier 3 downlink. The object aimosSubRackV1AttenuationAge indicates the age of this information. Changes, which are made here, affect the ha…
1.3.6.1.4.1.6408.201.3.5.14.1.9ColumnaimosSubRackV1AttenuationAmp3ULread-writecurrentAttenuation on amplifier 3 uplink. The object aimosSubRackV1AttenuationAge indicates the age of this information. Changes, which are made here, affect the hard…
1.3.6.1.4.1.6408.201.3.5.14.1.10ColumnaimosSubRackV1GainOffsetAgeread-writecurrentIn both the uplink (UL) and the downlink (DL) path for each of the three bands provided by the three amplifiers (1 to 3), the gain offset can be read-off and i…
1.3.6.1.4.1.6408.201.3.5.14.1.11ColumnaimosSubRackV1GainOffsetAmp1DLread-writecurrentGain offset on amplifier 1 downlink. The object aimosSubRackV1GainOffsetAge indicates the age of this information. Changes, which are made here, affect the har…
1.3.6.1.4.1.6408.201.3.5.14.1.12ColumnaimosSubRackV1GainOffsetAmp1ULread-writecurrentGain offset on amplifier 1 uplink. The object aimosSubRackV1GainOffsetAge indicates the age of this information. Changes, which are made here, affect the hardw…
1.3.6.1.4.1.6408.201.3.5.14.1.13ColumnaimosSubRackV1GainOffsetAmp2DLread-writecurrentGain offset on amplifier 2 downlink. The object aimosSubRackV1GainOffsetAge indicates the age of this information. Changes, which are made here, affect the har…
1.3.6.1.4.1.6408.201.3.5.14.1.14ColumnaimosSubRackV1GainOffsetAmp2ULread-writecurrentGain offset on amplifier 2 uplink. The object aimosSubRackV1GainOffsetAge indicates the age of this information. Changes, which are made here, affect the hardw…
1.3.6.1.4.1.6408.201.3.5.14.1.15ColumnaimosSubRackV1GainOffsetAmp3DLread-writecurrentGain offset on amplifier 3 downlink. The object aimosSubRackV1GainOffsetAge indicates the age of this information. Changes, which are made here, affect the har…
1.3.6.1.4.1.6408.201.3.5.14.1.16ColumnaimosSubRackV1GainOffsetAmp3ULread-writecurrentGain offset on amplifier 3 uplink. The object aimosSubRackV1GainOffsetAge indicates the age of this information. Changes, which are made here, affect the hardw…
1.3.6.1.4.1.6408.201.3.5.14.1.17ColumnaimosSubRackV1TemperatureAgeread-writecurrentaimosSubRackV1TemperatureBoard is an object of the TemperatureStatus type and contains the temperature measured at the SubRack Master Unit, in degrees Celsius.…
1.3.6.1.4.1.6408.201.3.5.14.1.18ColumnaimosSubRackV1TemperatureBoardread-onlycurrentTemperature in degrees centigrade measured at the Sub Rack Master Unit. The object aimosSubRackV1TemperatureAge indicates the age of this information.
1.3.6.1.4.1.6408.201.3.5.14.1.19ColumnaimosSubRackV1AmplifierBandNamesAgeread-writecurrentBoth Sub Rack Master Unit and each of its connected Remote Units have up to three amplifiers. The objects . aimosSubRackV1Amplifier1BandName . aimosSubRackV1Am…
1.3.6.1.4.1.6408.201.3.5.14.1.20ColumnaimosSubRackV1Amplifier1BandNameread-onlycurrentStates which frequency band (UMTS, GSM1800, GSM900, or any else) is assigned to amplifier 1. The object aimosSubRackV1AmplifierBandNamesAge indicates the age o…
1.3.6.1.4.1.6408.201.3.5.14.1.21ColumnaimosSubRackV1Amplifier2BandNameread-onlycurrentStates which frequency band (UMTS, GSM1800, GSM900, or any else) is assigned to amplifier 2. The object aimosSubRackV1AmplifierBandNamesAge indicates the age o…
1.3.6.1.4.1.6408.201.3.5.14.1.22ColumnaimosSubRackV1Amplifier3BandNameread-onlycurrentStates which frequency band (UMTS, GSM1800, GSM900, or any else) is assigned to amplifier 3. The object aimosSubRackV1AmplifierBandNamesAge indicates the age o…
1.3.6.1.4.1.6408.201.3.5.15TableaimosRemoteUnitV1Tablenot-accessiblecurrentThis table contains information's about Remote Units with hardware revision 1. Insert rows: must only be done by system Delete rows: must only be done by system
1.3.6.1.4.1.6408.201.3.5.15.1RowaimosRemoteUnitV1Entrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.15.1.1ColumnaimosRemoteV1UnitReferenceread-onlycurrentThis object of type UnitReference is the first index of this table. It unambiguously identifies the unit, independent of its kind (Master Unit, Sub Rack Master…
1.3.6.1.4.1.6408.201.3.5.15.1.2ColumnaimosRemoteV1ValueSourceread-onlycurrentThis object of type ValueSource is the second index in this table. It indicates, which value is to be addressed (actual, cached or desired value): . actual : A…
1.3.6.1.4.1.6408.201.3.5.15.1.3ColumnaimosRemoteV1NominalTemperatureAgeread-writecurrentaimosRemoteUnitV1NominalTemperature is an object of type NominalTemperature, where the temperature to be obtained by fan control is entered in degrees centigra…
1.3.6.1.4.1.6408.201.3.5.15.1.4ColumnaimosRemoteV1NominalTemperatureread-writecurrentTemperature to be obtained by fan control in degrees centigrade. The object aimosRemoteV1NominalTemperatureAge indicates the age of this information. Changes, …
1.3.6.1.4.1.6408.201.3.5.15.1.5ColumnaimosRemoteV1TemperatureAgeread-writecurrentThe Remote Unit has five temperature probes. For this, the MIB contains the following objects: . aimosRemoteV1TemperatureAmp1 . aimosRemoteV1TemperatureAmp2 . …
1.3.6.1.4.1.6408.201.3.5.15.1.6ColumnaimosRemoteV1TemperatureAmp1read-onlycurrentAmplifier 1 temperature in degrees centigrade. The object aimosRemoteV1TemperatureAge indicates the age of this information.
1.3.6.1.4.1.6408.201.3.5.15.1.7ColumnaimosRemoteV1TemperatureAmp2read-onlycurrentAmplifier 2 temperature in degrees centigrade. The object aimosRemoteV1TemperatureAge indicates the age of this information.
1.3.6.1.4.1.6408.201.3.5.15.1.8ColumnaimosRemoteV1TemperatureAmp3read-onlycurrentAmplifier 3 temperature in degrees centigrade. The object aimosRemoteV1TemperatureAge indicates the age of this information.
1.3.6.1.4.1.6408.201.3.5.15.1.9ColumnaimosRemoteV1TemperatureBoardread-onlycurrentBoard temperature in degrees centigrade. The object aimosRemoteV1TemperatureAge indicates the age of this information.
1.3.6.1.4.1.6408.201.3.5.15.1.10ColumnaimosRemoteV1TemperaturePowerSupplyread-onlycurrentPower supply temperature in degrees centigrade. The object aimosRemoteV1TemperatureAge indicates the age of this information.
1.3.6.1.4.1.6408.201.3.5.15.1.11ColumnaimosRemoteV1AmplifierStateAgeread-writecurrentThe downlink amplifiers for each one of the three frequency bands supported by the Remote Unit can be switched individually. For this, the MIB contains the fol…
1.3.6.1.4.1.6408.201.3.5.15.1.12ColumnaimosRemoteV1Amplifier1Stateread-writecurrentDenotes if the amplifier 1 is active or not. The object aimosRemoteV1AmplifierStateAge indicates the age of this information. Changes, which are made here, aff…
1.3.6.1.4.1.6408.201.3.5.15.1.13ColumnaimosRemoteV1Amplifier2Stateread-writecurrentDenotes if the amplifier 2 is active or not. The object aimosRemoteV1AmplifierStateAge indicates the age of this information. Changes, which are made here, aff…
1.3.6.1.4.1.6408.201.3.5.15.1.14ColumnaimosRemoteV1Amplifier3Stateread-writecurrentDenotes if the amplifier 3 is active or not. The object aimosRemoteV1AmplifierStateAge indicates the age of this information. Changes, which are made here, aff…
1.3.6.1.4.1.6408.201.3.5.15.1.15ColumnaimosRemoteV1AmplifierPowerAgeread-writecurrentThe output power at the downlink amplifiers for each one of the three frequency bands supported by the Remote Unit can be read off individually. For this, the …
1.3.6.1.4.1.6408.201.3.5.15.1.16ColumnaimosRemoteV1Amplifier1Powerread-onlycurrentPower of amplifier 1 in dB. The object aimosRemoteV1AmplifierPowerAge indicates the age of this information.
1.3.6.1.4.1.6408.201.3.5.15.1.17ColumnaimosRemoteV1Amplifier2Powerread-onlycurrentPower of amplifier 2 in dB. The object aimosRemoteV1AmplifierPowerAge indicates the age of this information.
1.3.6.1.4.1.6408.201.3.5.15.1.18ColumnaimosRemoteV1Amplifier3Powerread-onlycurrentPower of amplifier 3 in dB. The object aimosRemoteV1AmplifierPowerAge indicates the age of this information.
1.3.6.1.4.1.6408.201.3.5.15.1.19ColumnaimosRemoteV1AttenuationAgeread-writecurrentFor both the uplink (UL) and downlink (DL) paths the attenuation of the corresponding attenuator (located at the optical unit) required for Autolevelling for e…
1.3.6.1.4.1.6408.201.3.5.15.1.20ColumnaimosRemoteV1AttenuationAmp1DLread-writecurrentAttenuation on amplifier 1 downlink. The object aimosRemoteV1AttenuationAge indicates the age of this information. Changes, which are made here, affect the har…
1.3.6.1.4.1.6408.201.3.5.15.1.21ColumnaimosRemoteV1AttenuationAmp1ULread-writecurrentAttenuation on amplifier 1 uplink. The object aimosRemoteV1AttenuationAge indicates the age of this information. Changes, which are made here, affect the hardw…
1.3.6.1.4.1.6408.201.3.5.15.1.22ColumnaimosRemoteV1AttenuationAmp2DLread-writecurrentAttenuation on amplifier 2 downlink. The object aimosRemoteV1AttenuationAge indicates the age of this information. Changes, which are made here, affect the har…
1.3.6.1.4.1.6408.201.3.5.15.1.23ColumnaimosRemoteV1AttenuationAmp2ULread-writecurrentAttenuation on amplifier 2 uplink. The object aimosRemoteV1AttenuationAge indicates the age of this information. Changes, which are made here, affect the hardw…
1.3.6.1.4.1.6408.201.3.5.15.1.24ColumnaimosRemoteV1AttenuationAmp3DLread-writecurrentAttenuation on amplifier 3 downlink. The object aimosRemoteV1AttenuationAge indicates the age of this information. Changes, which are made here, affect the har…
1.3.6.1.4.1.6408.201.3.5.15.1.25ColumnaimosRemoteV1AttenuationAmp3ULread-writecurrentAttenuation on amplifier 3 uplink. The object aimosRemoteV1AttenuationAge indicates the age of this information. Changes, which are made here, affect the hardw…
1.3.6.1.4.1.6408.201.3.5.15.1.26ColumnaimosRemoteV1GainOffsetAgeread-writecurrentFor both the uplink (UL) and downlink (DL) paths the gain offset for each one of the three frequency bands can be read off individually or may be changed (only…
1.3.6.1.4.1.6408.201.3.5.15.1.27ColumnaimosRemoteV1GainOffsetAmp1DLread-writecurrentGain offset on amplifier 1 downlink. The object aimosRemoteV1GainOffsetAge indicates the age of this information. Changes, which are made here, affect the hard…
1.3.6.1.4.1.6408.201.3.5.15.1.28ColumnaimosRemoteV1GainOffsetAmp1ULread-writecurrentGain offset on amplifier 1 uplink. The object aimosRemoteV1GainOffsetAge indicates the age of this information. Changes, which are made here, affect the hardwa…
1.3.6.1.4.1.6408.201.3.5.15.1.29ColumnaimosRemoteV1GainOffsetAmp2DLread-writecurrentGain offset on amplifier 2 downlink. The object aimosRemoteV1GainOffsetAge indicates the age of this information. Changes, which are made here, affect the hard…
1.3.6.1.4.1.6408.201.3.5.15.1.30ColumnaimosRemoteV1GainOffsetAmp2ULread-writecurrentGain offset on amplifier 2 uplink. The object aimosRemoteV1GainOffsetAge indicates the age of this information. Changes, which are made here, affect the hardwa…
1.3.6.1.4.1.6408.201.3.5.15.1.31ColumnaimosRemoteV1GainOffsetAmp3DLread-writecurrentGain offset on amplifier 3 downlink. The object aimosRemoteV1GainOffsetAge indicates the age of this information. Changes, which are made here, affect the hard…
1.3.6.1.4.1.6408.201.3.5.15.1.32ColumnaimosRemoteV1GainOffsetAmp3ULread-writecurrentGain offset on amplifier 3 uplink. The object aimosRemoteV1GainOffsetAge indicates the age of this information. Changes, which are made here, affect the hardwa…
1.3.6.1.4.1.6408.201.3.5.15.1.33ColumnaimosRemoteV1ALCThresholdAgeread-writecurrentFor each one of the three frequency bands supported by the Remote Unit . the output power at the downlink amplifier can be limited (DL) and . the input power a…
1.3.6.1.4.1.6408.201.3.5.15.1.34ColumnaimosRemoteV1ALCThresholdAmp1DLread-writecurrentALC threshold on amplifier 1 downlink. The object aimosRemoteV1ALCThresholdAge indicates the age of this information. Changes, which are made here, affect the …
1.3.6.1.4.1.6408.201.3.5.15.1.35ColumnaimosRemoteV1ALCThresholdAmp1ULread-writecurrentALC threshold on amplifier 1 uplink. The object aimosRemoteV1ALCThresholdAge indicates the age of this information. Changes, which are made here, affect the ha…
1.3.6.1.4.1.6408.201.3.5.15.1.36ColumnaimosRemoteV1ALCThresholdAmp2DLread-writecurrentALC threshold on amplifier 2 downlink. The object aimosRemoteV1ALCThresholdAge indicates the age of this information. Changes, which are made here, affect the …
1.3.6.1.4.1.6408.201.3.5.15.1.37ColumnaimosRemoteV1ALCThresholdAmp2ULread-writecurrentALC threshold on amplifier 2 uplink. The object aimosRemoteV1ALCThresholdAge indicates the age of this information. Changes, which are made here, affect the ha…
1.3.6.1.4.1.6408.201.3.5.15.1.38ColumnaimosRemoteV1ALCThresholdAmp3DLread-writecurrentALC threshold on amplifier 3 downlink. The object aimosRemoteV1ALCThresholdAge indicates the age of this information. Changes, which are made here, affect the …
1.3.6.1.4.1.6408.201.3.5.15.1.39ColumnaimosRemoteV1ALCThresholdAmp3ULread-writecurrentALC threshold on amplifier 3 uplink. The object aimosRemoteV1ALCThresholdAge indicates the age of this information. Changes, which are made here, affect the ha…
1.3.6.1.4.1.6408.201.3.5.15.1.40ColumnaimosRemoteV1OpticalLossAgeread-writecurrentFor both the uplink and downlink paths the optical loss can be read-off via the following two objects in the MIB: . aimosRemoteV1OpticalLossDL and . aimosRemot…
1.3.6.1.4.1.6408.201.3.5.15.1.41ColumnaimosRemoteV1OpticalLossDLread-onlycurrentOptical loss on downlink fibre. The object aimosRemoteV1OpticalLossAge indicates the age of this information.
1.3.6.1.4.1.6408.201.3.5.15.1.42ColumnaimosRemoteV1OpticalLossULread-onlycurrentOptical loss on uplink fibre. The object aimosRemoteV1OpticalLossAge indicates the age of this information.
1.3.6.1.4.1.6408.201.3.5.15.1.43ColumnaimosRemoteV1Output1Nameread-writecurrentNames the output pin 1 for recognition what is connected. Changes, which are made here, affect the hardware. That's why TelCo's are not allowed to make any cha…
1.3.6.1.4.1.6408.201.3.5.15.1.44ColumnaimosRemoteV1Output2Nameread-writecurrentNames the output pin 2 for recognition what is connected. Changes, which are made here, affect the hardware. That's why TelCo's are not allowed to make any cha…
1.3.6.1.4.1.6408.201.3.5.15.1.45ColumnaimosRemoteV1Output3Nameread-writecurrentNames the output pin 3 for recognition what is connected. Changes, which are made here, affect the hardware. That's why TelCo's are not allowed to make any cha…
1.3.6.1.4.1.6408.201.3.5.15.1.46ColumnaimosRemoteV1Output4Nameread-writecurrentNames the output pin 4 for recognition what is connected. Changes, which are made here, affect the hardware. That's why TelCo's are not allowed to make any cha…
1.3.6.1.4.1.6408.201.3.5.15.1.47ColumnaimosRemoteV1OutputAgeread-writecurrentEach of the four digital outputs available at the Remote Unit can be accessed individually via one of the following four objects: . aimosRemoteV1Output1Value, …
1.3.6.1.4.1.6408.201.3.5.15.1.48ColumnaimosRemoteV1Output1Valueread-writecurrentState on external out pin 1. The object aimosRemoteV1OutputAge indicates the age of this information. Changes, which are made here, affect the hardware. That's…
1.3.6.1.4.1.6408.201.3.5.15.1.49ColumnaimosRemoteV1Output2Valueread-writecurrentState on external out pin 2. The object aimosRemoteV1OutputAge indicates the age of this information. Changes, which are made here, affect the hardware. That's…
1.3.6.1.4.1.6408.201.3.5.15.1.50ColumnaimosRemoteV1Output3Valueread-writecurrentState on external out pin 3. The object aimosRemoteV1OutputAge indicates the age of this information. Changes, which are made here, affect the hardware. That's…
1.3.6.1.4.1.6408.201.3.5.15.1.51ColumnaimosRemoteV1Output4Valueread-writecurrentState on external out pin 4. The object aimosRemoteV1OutputAge indicates the age of this information. Changes, which are made here, affect the hardware. That's…
1.3.6.1.4.1.6408.201.3.5.15.1.52ColumnaimosRemoteV1Input1Nameread-writecurrentNames the input pin 1 for recognition what is connected. Changes, which are made here, affect the hardware. That's why TelCo's are not allowed to make any chan…
1.3.6.1.4.1.6408.201.3.5.15.1.53ColumnaimosRemoteV1Input2Nameread-writecurrentNames the input pin 2 for recognition what is connected. Changes, which are made here, affect the hardware. That's why TelCo's are not allowed to make any chan…
1.3.6.1.4.1.6408.201.3.5.15.1.54ColumnaimosRemoteV1Input3Nameread-writecurrentNames the input pin 3 for recognition what is connected. Changes, which are made here, affect the hardware. That's why TelCo's are not allowed to make any chan…
1.3.6.1.4.1.6408.201.3.5.15.1.55ColumnaimosRemoteV1Input4Nameread-writecurrentNames the input pin 4 for recognition what is connected. Changes, which are made here, affect the hardware. That's why TelCo's are not allowed to make any chan…
1.3.6.1.4.1.6408.201.3.5.16TableaimosGSMNSOV1Tablenot-accessiblecurrentHardware version related informations about the GSM NSO's. Insert rows: must only be done by system Delete rows: must only be done by system
1.3.6.1.4.1.6408.201.3.5.16.1RowaimosGSMNSOV1Entrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.16.1.1ColumnaimosGSMNSOV1UnitReferenceread-onlycurrentThis object of type UnitReference is the first index of this table. It unambiguously identifies the unit, independent of its kind (Master Unit, Sub Rack Master…
1.3.6.1.4.1.6408.201.3.5.16.1.2ColumnaimosGSMNSOV1ValueSourceread-onlycurrentThis object of type ValueSource is the second index in this table. It indicates, which value is to be addressed (actual, cached or desired value): . actual : A…
1.3.6.1.4.1.6408.201.3.5.16.1.3ColumnaimosGSMNSOV1Nameread-onlycurrentPresents the unique 8 character name of the NSO.
1.3.6.1.4.1.6408.201.3.5.16.1.4ColumnaimosGSMNSOV1ScanIntervalread-writecurrentDenotes the intervall time the NSO will restart its measurement. Note, the NSO needs approximately 60 seconds for measurement and some seconds for transmitting…
1.3.6.1.4.1.6408.201.3.5.16.1.5ColumnaimosGSMNSOV1ScanBCCHread-writecurrentDenotes if the BCCH channel will be scanned.
1.3.6.1.4.1.6408.201.3.5.16.1.6ColumnaimosGSMNSOV1CellStatusread-writecurrentCell State Bit Remark 0 CELL_SUITABLE 1 CELL_LOW_PRIORITY 2 CELL_BARRED 3 CELL_LOW_LEVEL 4 CELL_FORBIDDEN 5 CELL_OTHER Other cell states indicating an alarm st…
1.3.6.1.4.1.6408.201.3.5.16.1.7ColumnaimosGSMNSOV1MinScanSignalStrengthread-writecurrentChannels with a lower RX level are not scanned.
1.3.6.1.4.1.6408.201.3.5.16.1.8ColumnaimosGSMNSOV1SignalStrengthHysteresisread-writecurrentSignal strength modifications within the hysteresis do not cause the NSO to send data with new signal strength values. E.g., a hysteresis of +/- 1 dB ignores s…
1.3.6.1.4.1.6408.201.3.5.16.1.9ColumnaimosGSMNSOV1MinAllowedSignalStrengthread-writecurrentRX levels with a lower level indicating an alarm state.
1.3.6.1.4.1.6408.201.3.5.16.1.10ColumnaimosGSMNSOV1MaxAllowedSignalStrengthread-writecurrentRX levels with a higher level indicating an alarm state.
1.3.6.1.4.1.6408.201.3.5.16.1.11ColumnaimosGSMNSOV1MaxAllowedBERread-writecurrentBit Error Rates with a higher level indicating an alarm state.
1.3.6.1.4.1.6408.201.3.5.17TableaimosGSMNSODataV1Tablenot-accessiblecurrentGSM NSO measurement data. Insert rows: must only be done by system Delete rows: must only be done by system
1.3.6.1.4.1.6408.201.3.5.17.1RowaimosGSMNSODataV1Entrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.17.1.1ColumnaimosGSMNSODataV1IDread-onlycurrentIdentifies the table entry. This value ist determined by the system.
1.3.6.1.4.1.6408.201.3.5.17.1.2ColumnaimosGSMNSODataV1LACread-onlycurrentLocal Area Code.
1.3.6.1.4.1.6408.201.3.5.17.1.3ColumnaimosGSMNSODataV1CIread-onlycurrentCell Identifier
1.3.6.1.4.1.6408.201.3.5.17.1.4ColumnaimosGSMNSODataV1DateTimeread-onlycurrentTime of measurement.
1.3.6.1.4.1.6408.201.3.5.17.1.5ColumnaimosGSMNSODataV1ARFCNread-onlycurrentChannel
1.3.6.1.4.1.6408.201.3.5.17.1.6ColumnaimosGSMNSODataV1BSICread-onlycurrentBase Station Identity Code.
1.3.6.1.4.1.6408.201.3.5.17.1.7ColumnaimosGSMNSODataV1CSread-onlycurrentCell Status
1.3.6.1.4.1.6408.201.3.5.17.1.8ColumnaimosGSMNSODataV1SignalStrengthread-onlycurrentCurrent RX level.
1.3.6.1.4.1.6408.201.3.5.17.1.9ColumnaimosGSMNSODataV1BERread-onlycurrentCurrent Bit Error Rate.
1.3.6.1.4.1.6408.201.3.5.18TableaimosUMTSNSOV1Tablenot-accessiblecurrentHardware version related informations about the UMTS NSO's. Insert rows: must only be done by system Delete rows: must only be done by system
1.3.6.1.4.1.6408.201.3.5.18.1RowaimosUMTSNSOV1Entrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.18.1.1ColumnaimosUMTSNSOV1UnitReferenceread-onlycurrentThis object of type UnitReference is the first index of this table. It unambiguously identifies the unit, independent of its kind (Master Unit, Sub Rack Master…
1.3.6.1.4.1.6408.201.3.5.18.1.2ColumnaimosUMTSNSOV1ValueSourceread-onlycurrentThis object of type ValueSource is the second index in this table. It indicates, which value is to be addressed (actual, cached or desired value): . actual : A…
1.3.6.1.4.1.6408.201.3.5.19TableaimosUMTSNSODataV1Tablenot-accessiblecurrentUMTS NSO measurement data. Insert rows: must only be done by system Delete rows: must only be done by system
1.3.6.1.4.1.6408.201.3.5.19.1RowaimosUMTSNSODataV1Entrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.5.19.1.1ColumnaimosUMTSNSODataV1IDread-onlycurrentIdentifies the table entry. This value ist determined by the system.
1.3.6.1.4.1.6408.201.3.6IdentityaimosNEOperationscurrentThis object identity provides means to execute Network Element Operations. For example it is possible to request for a reboot of a NE.
1.3.6.1.4.1.6408.201.3.6.1TableaimosNEOperationsTablenot-accessiblecurrentThis table contains the Network Elements capable of operation execution. The following Network Elements are supported (V 2.8.0): - Node M - Node C - Node G - N…
1.3.6.1.4.1.6408.201.3.6.1.1RowaimosNEOperationsEntrynot-accessiblecurrentsee description for table entry...
1.3.6.1.4.1.6408.201.3.6.1.1.1ColumnaimosNEOperationsIDread-onlycurrentThis object of type UnitReference uniquely identifies the Network Element. This value is related to the column 'NE No.' of the 'Network Element List' (A.I.M.O.…
1.3.6.1.4.1.6408.201.3.6.1.1.2ColumnaimosNEOperationsSDNread-onlycurrentThis object of type SDN shows the System Distinguished Name which consists of a chaining of all RDN's all the way down from the OMC point of view to the desire…
1.3.6.1.4.1.6408.201.3.6.1.1.3ColumnaimosNEOperationsTrapInforead-onlycurrentThis object of type Text contains the Network Elements TrapInfo.
1.3.6.1.4.1.6408.201.3.6.1.1.4ColumnaimosNEOperationsComponentNameread-onlycurrentThis object of type Text contains the Network Elements Component Name.
1.3.6.1.4.1.6408.201.3.6.1.1.5ColumnaimosNEOperationsLocationread-onlycurrentThis object of type Text contains the Network Elements Location.
1.3.6.1.4.1.6408.201.3.6.1.1.6ColumnaimosNEOperationsUniqueSystemIDread-onlycurrentThis object of type Text contains the Network Elements Unique System ID.
1.3.6.1.4.1.6408.201.3.6.1.1.50ColumnaimosNEOperationsNEActiveread-onlycurrentThis object of type Boolean indicates whether or not a Network Element (or at least one component capable of de-/activation if applicable) is active. This obje…
1.3.6.1.4.1.6408.201.3.6.1.1.51ColumnaimosNEOperationsDeactivateNEread-writecurrentThis object of type NEOperationStatus provides means to deactivate a Network Element by applying a value of neoSubmit(2). Deactivation is performed in the foll…
1.3.6.1.4.1.6408.201.3.6.1.1.52ColumnaimosNEOperationsDeactivateNEInforead-onlycurrentThis object of type Text is the textual representation of the value retunred by aimosNEOperationsDeactivateNE. In case it is neoFailed(10) a more precise descr…
1.3.6.1.4.1.6408.201.3.6.1.1.53ColumnaimosNEOperationsActivateNEread-writecurrentThis object of type NEOperationStatus provides means to activate a Network Element by applying a value of neoSubmit(2). Activation is performed in the followin…
1.3.6.1.4.1.6408.201.3.6.1.1.54ColumnaimosNEOperationsActivateNEInforead-onlycurrentThis object of type Text is the textual representation of the value retunred by aimosNEOperationsActivateNE. In case it is neoFailed(10) a more precise descrip…
1.3.6.1.4.1.6408.201.3.6.1.1.60ColumnaimosNEOperationsRebootread-writecurrentThis object of type NEOperationStatus provides means to initiate a reboot of a Network Element by applying a value of neoSubmit(2). Furthermore its values indi…
1.3.6.1.4.1.6408.201.3.6.1.1.61ColumnaimosNEOperationsRebootInforead-onlycurrentThis object of type Text is the textual representation of the value retunred by aimosNEOperationsReboot. In case it is neoFailed(10) a more precise description…
1.3.6.1.4.1.6408.201.3.6.1.1.70ColumnaimosNEOperationsQueryAlarmsread-writecurrentThis object of type NEOperationStatus provides means to forward a Query Alarms Command to a Network Element by applying a value of neoSubmit(2). Furthermore it…
1.3.6.1.4.1.6408.201.3.6.1.1.71ColumnaimosNEOperationsQueryAlarmsInforead-onlycurrentThis object of type Text is the textual representation of the value retunred by aimosNEOperationsQueryAlarms. In case it is neoFailed(10) a more precise descri…
1.3.6.1.4.1.6408.201.4IdentityaimosNotificationscurrentThe A.I.M.O.S. SNMP Agent sends alarm notifications to as many alarm recipients as desired. All notifications contains the following objects: . sysUpTime durat…
1.3.6.1.4.1.6408.201.4.1ScalaraimosAgentStateaccessible-for-notifycurrentThis value indicates what the agent is about to do. Please refer also to the DESCRIPTION clause for aimosAgentAnnouncement.
1.3.6.1.4.1.6408.201.4.2ScalaraimosAcknowledgementOIDaccessible-for-notifycurrentThis object comprises the OID, the value of which must be set to acknowledged(2) in order to confirm the alarm reception (i.e. perform the acknowledgement). If…
1.3.6.1.4.1.6408.201.4.3ScalaraimosTrapEnterpriseaccessible-for-notifycurrentThis object was intended to carry the entrerprise OID value in notifications, although the existing object snmpTrapEnterprise had already exactly this task. Th…
1.3.6.1.4.1.6408.201.4.4NotificationaimosAgentAnnouncementcurrentA aimosAgentAnnouncement notification is emitted by the agent if it is put in or out of operation. aimosAgentState of type AgentState indicates what actually h…
1.3.6.1.4.1.6408.201.4.5NotificationaimosAlarmNewcurrentThe aimosAlarmNew notification is used when a new alarm appears. It contains a new aimosAlarmListAlarmEventID. The aimosAlarmNew notification causes the A.I.M.…
1.3.6.1.4.1.6408.201.4.6NotificationaimosAlarmChangedcurrentThe aimosAlarmChanged notification is used when the severity of an uncleared alarm has changed. The alarm is correlated with the aimosAlarmNew notification by …
1.3.6.1.4.1.6408.201.4.7NotificationaimosAlarmClearedcurrentThe aimosAlarmCleared notification is used when an alarm gets cleared. The alarm is correlated with the aimosAlarmNew and aimosAlarmCleared notification by ide…
1.3.6.1.4.1.6408.201.4.8NotificationaimosAlarmListRebuildInitiatedcurrentThe aimosAlarmListRebuildInitiated notification is sent, when an alarm list rebuild process was triggered. The notification will be emitted prior to the rebuil…
1.3.6.1.4.1.6408.201.4.9NotificationaimosHeartbeatcurrentThe aimosHeartbeat notification is sent out each [aimosWorkShiftHeartbeatInterval] minutes to the members of the Alarm Recipient List specified by the object […
1.3.6.1.4.1.6408.201.4.10NotificationaimosAlarmRecognizedcurrentThe aimosAlarmRecognized alarm is raised in case an alarm is recognized . either via aimosAlarmListRecognitionState . by means of the AIMOS_VIsu program The de…
1.3.6.1.4.1.6408.201.5IdentityaimosGroupscurrentGroup objects
1.3.6.1.4.1.6408.201.5.1GroupaimosMIB2GroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.2GroupaimosLoginGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.4GroupaimosSystemInfoGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.5GroupaimosSystemConfigGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.6GroupaimosBandConfigGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.7GroupaimosBandInfoGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.8GroupaimosUserGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.9GroupaimosRoleGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.10GroupaimosPhoneBookGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.11GroupaimosAlarmConfigGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.12GroupaimosAlarmConfigGroupDeprecateddeprecatedDescription.
1.3.6.1.4.1.6408.201.5.13GroupaimosAlarmInfoGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.14GroupaimosAlarmGroupConfigGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.15GroupaimosMasterGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.16GroupaimosMasterV1GroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.17GroupaimosSubRackGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.18GroupaimosSubRackV1GroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.19GroupaimosRemoteGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.20GroupaimosRemoteV1GroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.21GroupaimosGSMNSOGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.22GroupaimosGSMNSOV1GroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.23GroupaimosUMTSNSOGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.24GroupaimosUMTSNSOV1GroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.27GroupaimosCableConfigGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.29GroupaimosNotificationGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.30GroupmidsNotificationsGroupcurrentDescription.
1.3.6.1.4.1.6408.201.5.31GroupaimosNetworkElementOperationsGroupcurrentDescription.
1.3.6.1.4.1.6408.201.6IdentityaimosCompliancescurrentCompliance objects
1.3.6.1.4.1.6408.201.6.1ComplianceaimosCompliancecurrentDescription.
Type Definitions
NameSyntaxStatusDescription
AccessRightINTEGER { noAccess(0), readOnly(1), readWrite(2) }currentAccessRight is an INTEGER used in order to indicate the access rights of an user with the following named values: . noAccess(0) used in order to delete entries in aimosRoleRightTable . readOnly(1) updates are prohibited…
AcknowledgementStateINTEGER { indeterminate(0), unacknowledged(1), acknowledged(2) }currentAcknowledgementState is an INTEGER used in order to indicate the acknowledgement state of an alarm by the following named values: . indeterminate(0) corresponds to X.733, however in A.I.M.O.S. not used . unacknowledged(…
AgentStateINTEGER { snmpColdStart(1), snmpPause(2), snmpResume(3), snmpShutDown(4) }currentAgentState is an INTEGER value used in order to indicate what the A.I.M.O.S. SNMP Agent is about to do by the following named values: . snmpColdStart(1) the agent was started and is now running . snmpPause(2) not yet us…
AlarmForwardingTypeINTEGER { disabled(0), snmpV1(1), snmpV2c(2) }currentAlarmForwardingType is an INTEGER used in order to indicate the type of alarm forwarding by the following named values: . disabled(0) alarm forwarding is disabled . snmpV1(1) alarm forwarding is using the TRAP-TYPE cons…
AlarmIDINTEGER { alarmAC(1), alarmALC(2), alarmAmplifier(3), alarmAmplifierCurrent(4), alarmAttSet(5), alarmAutoLeveling(6), alarmAuxSet(7), alarmBitErrorRate(8), alarmBooster(9), alarmBus(10), alarmChannel(11), alarmCellLost(13), alarmConnection(15), alarmControlBoard(16), alarmConvBias(17), alarmConverter(18), alarmCellStatusChanged(19), alarmCurrent(20), alarmCurrentFail(21), alarmDistribution(22), alarmDistributor(23), alarmDoorOpen(24), alarmDriverAmp(25), alarmEnergyCellTemp(26), alarmEnergyCellVoltage(27), alarmExternalInput(28), alarmFan(29), alarmHeartBeat(30), alarmICEOscilPower(31), alarmInputPower(32), alarmMIB(33), alarmMicrowaveLock(34), alarmOperatorRequired(35), alarmOptic(36), alarmOpticCurrent(37), alarmOscillator(38), alarmPA(39), alarmPasswordWrong(40), alarmPowerAmplifier(41), alarmPowerOut(42), alarmPowerOutBelowLimit(43), alarmPowerOutLow(44), alarmPowerSupply(45), alarmPreAmplifier(46), alarmRelay(47), alarmRFPath(48), alarmRSSI(49), alarmRSSILow(50), alarmRxLevelHigh(51), alarmRxLevelLow(52), alarmSolarVoltage(53), alarmSummarizer(54), alarmSynthesizerCurrent(55), alarmSynthesizer(56), alarmSystemModule(57), alarmSystemTemp(58), alarmUnitUnavailable(59), alarmVSWR(60), alarmAutoLevelingOutOfRange(61), alarmOMC(62), alarmHeartbeatMissing(63), alarmIPP(64), alarmCommonPilotChannelHigh(65), alarmCommonPilotChannelLow(66), alarmTemperatureStage1(67), alarmTemperatureStage2(68), alarmCurrent2(69), alarmInvalidLogin(70), alarmChannelNew(71), alarmChannelLost(72), alarmChannelAllocationChanged(73), alarmUMTSRxLevelHigh(74), alarmUMTSRxLevelLow(75), alarmUMTSCodePowerLow(76), alarmUMTSCPICHEnergyToNoiseRatioLow(77), alarmUMTSCPICHCodePowerHigh(78), alarmUMTSCPICHCodePowerLow(79), alarmUMTSBCHBlockErrorRateHigh(80), alarmUMTSPSCCodePowerLow(81), alarmUMTSChannelLost(82), alarmAlarmlistDeleted(83), alarmDataOutOfSequence(84), alarmExternalOutput(85), alarmGsmNso(86) }currentAlarmID is an INTEGER used in order to indicate the kind of alarm.
AlarmValueUnsigned32 (0..9999999)currentAlarmValue is an Unsigned32 value within the range from 0 to 9.999.999 used in order to provide an alarm dependent value.
ALCThresholdUnsigned32 (0..255)currentALCThreshold is an Unsigned32 value within the range from 0 to 255 used in order to represent ALC Threshold values.
AmplifierPowerInteger32 (-640..635)currentAmplifierPower is an Unsigned32 value within the range from -640 to 635 used in order to represent the power value in tenth of dB in steps of 0.5 dB. I.e., valid values are 5,10,15,...
ARFCNUnsigned32 (0..16383)currentARFCN is an Unsigned32 value within the range from 0 to 16.383 used in order to represent the absolute radio frequency channel number.
AttenuationInteger32 (0..30)currentAttenuation is an Unsigned32 value within the range from 0 to 30 used in order to provide an attenuation value in dB.
BERUnsigned32 (0..254)currentBER is an Unsigned32 value within the range from 0 to 254 used in order to represent the bit error rate in tenth of dB.
BooleanINTEGER { false(0), true(1) }currentBoolean is an INTEGER used in order to represent a boolean value by the named values of . false(0) . true(1)
CableCodeOCTET STRING (SIZE (1..40))currentCableCode is an OCTET STRING with a length of up to 40 characters used in order to represent the custom cable code, to which the fibre belongs. Each character must be in range 32 to 126 (' ' <space> to '~' <tilde>).
CableCodeConcatenatorOCTET STRING (SIZE (1))currentCableCodeConcatenator is an OCTET STRING with a fixed length of 1 character used in order to concatenate Cable Codes.
CableIDUnsigned32 (1..2147483647)currentCableID is an Unsigned32 value within the range from 1 to 2^32-1 used in order to represent the unique key for cables, which are used for interconnection between Remote Units and SubRack Master Units.
CellStatusINTEGER { cellSuitable(0), cellLowPriority(1), cellBarred(2), cellLowLevel(3), cellForbidden(4), cellOther(5) }currentCellStatus is an INTEGER used in order to indicate the cell status by the following named values: . cellSuitable(0) . cellLowPriority(1) . cellBarred(2) . cellLowLevel(3) . cellForbidden(4) . cellOther(5)
CIUnsigned32 (0..65535)currentCI is an Unsigned32 value within the range from 0 to 65.535 used in order to represent the cell identifier.
ClearModeINTEGER { indeterminate(0), autoClear(1), manualClear(2), clearOnAck(3), ackIsClear(4) }currentClearMode is an INTEGER used in order to indicate how an alarm gets cleared by the following named values: . indeterminate(0) not used . autoClear(1) if the alarm condition does not exist any longer, a aimosAlarmCleared…
ClearReasonINTEGER { stillActive(0), autoCleared(1), manualCleared(2), objectDeleted(3), objectConfigured(4), alarmListRebuild(5), alarmChanged(6) }currentClearReason is an INTEGER used in order to indicate the reason of an alarm is going cleared by the following named values: . stillActive(0) what it says: the alarm is not cleared yet . autoCleared(1) the alarm was clear…
CommunityOCTET STRING (SIZE (1..40))currentCommunity is an OCTET STRING with up to 40 characters each being in range from 32 to 126 (' ' <space> to '~' <tilde>).
ControllerPasswordOCTET STRING (SIZE (6..8))currentControllerPassword is a OCTET STRING with the following requirements: . it consists of at least 6, but at the most 8 characters . it contains at least one capital letter in the range from A to Z . it contains at least o…
CoordinatesOCTET STRING (SIZE (0 | 3..21))currentCoordinates is an OCTET STRING with at least 3 up to 21 characters holding two values divided by a slash. The first one represents the x-coordinate and the other one represents the y-coordinate of a map position value.
DistinguishedNameHierarchySymbolOCTET STRING (SIZE (1))current
DistinguishedNameSeparatorOCTET STRING (SIZE (1))current
EventTypeINTEGER { communications(1), qualityOfService(2), processingError(3), equipment(4), environmental(5) }currentEventType is an INTEGER used in order to indicate the event type of an alarm by the following named values: . communications(1) . qualityOfService(2) . processingError(3) . equipment(4) . environmental(5)
FrequencyRangeUnsigned32 (400000..2400000)currentFrequencyRange is an Unsigned32 value within the range from 400.000 to 2.400.000 used in order to represent radio frequency values in kHz.
GainOffsetInteger32 (-9..9)currentGainOffset is an Unsigned32 value within the range from 0 to 30 used in order to provide an gain offset value.
GeographicPositionFormatINTEGER { degreeMinuteSecond(0), decimalSecond(1), decimalMinute(2), decimalDegree(3), signedValue(4) }currentFour formats are available: degreeMinuteSecond(0) shows degrees, minutes and seconds decimalSecond(1) shows degrees, minutes and decimal seconds decimalMinute(2) shows degrees and decimal minutes decimalDegree(3) shows …
GPSPositionOCTET STRING (SIZE (0..30))currentGPSPosition is an OCTET STRING with a length of up to 30 characters indicating either a latitude or a longitude. The format used is determined by aimosPhoneBookGeographicPositionFormat.
GUIDOCTET STRING (SIZE (38))currentGUID is an OCTET STRING with a fixed length of 38 character used in order to represent a Microsoft Windows GUID in printable format.
IdentNoOCTET STRING (SIZE (0..10))currentIdentNo is an OCTET STRING with up to 10 characters used in order to represent the Mikom Ident-No.
InterfaceTypeINTEGER { ifMIBDefault(0), ifOMC3Default(1), ifOMC3Nokia(2), ifNE3S(3), ifAimosObsolete(4), ifAimos(5) }currentInterfaceType is an INTEGER used in order to indicate the kind of alarm forwarding expected by the SNMP Manager by the following named values: . ifMIBDefault(0) currently the same as ifAimos(5) . ifOMC3Default(1) force …
IPAddressAndPortOCTET STRING (SIZE (7..21))currentIPAddressAndPort is an OCTET STRING with at least 7 up to 21 characters used in order to represent an IP address and its IP/UDP port number in the following format: a.b.c.d:port, e.g.: 192.168.1.54:162 If the port numbe…
LACUnsigned32 (1..65533)currentLocation Area CodeLAC is an Unsigned32 value within the range from 1 to 65.533 used in order to represent the location area code.
LocalTimeOCTET STRING (SIZE (10))currentLocalTime is an OCTET STRING having 10 octets used in order to represent date and time values in local time format. It consists of the following fields: field octets contents range 1 1-2 year 0..2999 2 3 month 1..12 3 4…
LoginStateINTEGER { disconnected(0), connected(1), refused(2), canceled(3), passwordExpired(4) }currentLoginState is an INTEGER value used in order to indicate the login state with the following named values: . disconnected(0) no access to OID's beneath aimosObjects . connected(1) access to all OID's of A.I.M.O.S. MIB (a…
MasterIDUnsigned32 (1..9999)currentMasterID is an Unsigned32 value within the range from 1 to 9.999 used in order to uniquely identify Master Units, each containing up to 13 Racks. While each Master Unit contains exact one Master Controller it is also us…
MasterStateINTEGER { indeterminate(0), requestGUID(1), performGUIDRequest(2), missingGUID(3), requestNetInfo(4), performNetInfoRequest(5), missingNetInfo(6), properlySet(7) }currentMasterState is an INTEGER value used in order to indicate the state of system integration with the following named values: . indeterminate(0) not used . requestGUID(1) used in order to inquire the Master Controller's GU…
MCCUnsigned32 (200..799)currentMCC is an Unsigned32 value within the range from 200 to 799 used in order to represent Mobile Country Codes.
MNCInteger32 (0..99)currentMNC is an Unsigned32 value within the range from 0 to 99 used in order to represent Mobile Network Codes.
NEOperationStatusINTEGER { neoNone(0), neoIdle(1), neoSubmit(2), neoQueued(3), neoPhysicalConnecting(4), neoPhysicalConnected(5), neoWaitingForSession(6), neoSessionEstablished(7), neoStarted(8), neoSucceeded(9), neoFailed(10) }currentNEOperationStatus is an INTEGER used in order to indicate the status of a Network Element Operation by the following named values: . neoNone(0) Network Element does not support this Operation . neoIdle(1) no operation s…
NetworkStandardINTEGER { umts(1), dcs(2), gsm(3) }currentNetworkStandard is an INTEGER used in order to indicate a network standards with the following named values: . umts(1) UMTS . dcs(2) GSM1800 . gsm(3) GSM900
NominalTemperatureInteger32 (40..65)currentNominalTemperature is an Unsigned32 value within the range from 40 to 65 used in order to adjust the desired temperature value in degrees centigrade.
NSOIDUnsigned32 (1)currentNSOID is an Unsigned32 value used in order to represent the unique key for GSM NSO's, each connected to one Remote Unit.
OperationModeINTEGER { idle(0), stopping(1), stop(2), running(3), starting(4), start(5) }currentOperationMode is an INTEGER used in order to indicate the operation mode by the following named values: . idle(0) no operation takes place at present . stopping(1) the operation is terminating . stop(2) used in order to…
OpticalLossInteger32 (-640..635)currentOpticalLoss is an Unsigned32 value within the range from -640 to 635 used in order to represent the optical loss value in tenth of dB.
OrgIDUnsigned32 (200000..799299)currentThe OrgID is an Unsigned32 value with a fixed length of 6 digits and the range from 200.000 to 799.299 used in order to represent organisation IDs. It contains: . MCC (mobile country code 3 digits) . TelCo/provider flag…
OrgLevelINTEGER { indeterminate(0), telco(1), provider(2), manufacturer(3) }currentOrgLevel is an INTEGER used in order to indicate the role the organisation is playing in the A.I.M.O.S. system with the following named values: . indeterminate(0) not used . telco(1) organisation is a TelCo . provider(2…
PasswordStandardINTEGER { normal(0), numbers(1), specials(2), numbersOrSpecials(3), numbersAndSpecials(4), upperCase(5), lowerCase(6), upperCaseAndLowerCase(7), upperCaseAndLowerCaseAndNumeric(8), upperCaseAndLowerCaseAndSpecial(9), upperCaseAndLowerCaseAndNumericOrSpecial(10), numericAndSpecialAndUpperCaseAndLowerCase(11) }currentPasswordStandard is an INTEGER value used in order to indicate the password security level by the following named values (the description indicates in each case, which character must be contained, so that a password is …
PasswordStringOCTET STRING (SIZE (5..100))currentPasswordString is an OCTET STRING with at least 5 up to 40 characters each being in a range from 32 to 126 (' ' <space> to '~' <tilde>). Each response to objects of type PasswordString will be a sequence of '*'.
PhoneBookEntryOCTET STRING (SIZE (1..100))currentPhoneBookEntry is an OCTET STRING with a length of at least 1 up to 100 characters used in order to give a phonebook entry a name. The name must start with a letter and each character must be in range 32 to 126 (' ' <sp…
ProbableCauseINTEGER { unknown(0), adapterError(1), applicationSubsystemFailure(2), bandwidthReduced(3), callEstablishmentError(4), communicationsProtocolError(5), communicationsSubsystemFailure(6), configurationOrCustomizationError(7), congestion(8), corruptData(9), cpuCyclesLimitExceeded(10), dTEDCEInterfaceError(11), dataSetOrModemError(12), degradedSignal(13), enclosureDoorOpen(14), equipmentMalfunction(15), excessiveVibration(16), fileError(17), fireDetected(18), floodDetected(19), framingError(20), heatingOrVentialtionOrCoolingSystemProblem(21), humidityUnacceptable(22), inputOutputDeviceError(23), inputDeviceError(24), lANError(25), leakDetected(26), localNodeTransmissionError(27), lossOfFrame(28), lossOfSignal(29), materialSupplyExhausted(30), multiplexerProblem(31), outOfMemory(32), outputDeviceError(33), performanceDegraded(34), powerProblem(35), pressureUnacceptable(36), processorProblem(37), pumpFailure(38), queueSizeExceeded(39), receiveFailure(40), receiverFailure(41), remoteNodeTransmissionError(42), resourceAtOrNearingCapacity(43), responseTimeExcessive(44), retransmissionRateExcessive(45), softwareError(46), softwareProgramAbnormallyTerminated(47), softwareProgramError(48), storageCapacityProblem(49), temperatureUnacceptable(50), thresholdCrossed(51), timingProblem(52), toxicLeakDetected(53), transmitFailure(54), transmitterFailure(55), underlyingResourceUnavailable(56), versionMismatch(57), snmpTrapColdStart(100), snmpTrapWarmStart(101), snmpTrapLinkDown(102), snmpTrapLinkUp(103), snmpTrapAuthenticationFailure(104), snmpTrapEgpNeighborloss(105), snmpTrapEnterpriseSpecific(106), snmpTrapLinkUpDown(107) }currentProbableCause is an INTEGER used in order to indicate the ITU-T Recommendation X.733 clause 8.1.2.1 conform probable cause of an alarm.
RDNOCTET STRING (SIZE (4..16))currentRDN is an OCTET STRING with up to 16 characters used in order to represent a relative distinguished name. The RDN uniquely identifies the unit within its parent. Each character must be in range 32 to 126 (' ' <space> to…
RecognitionStateINTEGER { indeterminate(0), unrecognized(1), recognized(2) }currentRecognitionState is an INTEGER used in order to indicate the recognition state of an alarm by the following named values: . indeterminate(0) . unrecognized(1) . recognized(2)
RemoteIDUnsigned32 (1..4)currentRemoteID is an Unsigned32 value with the range from 1 to 4 used in order to represent the unique key for a Remote Unit.
RightAreaINTEGER { administrationAlarms(100), administrationFolder(200), administrationMCAccounts(300), administrationMC(400), administrationOMCAccounts(500), administrationOMC(600), administrationSNMPNorthbound(700), administrationSNMPSouthbound(800), controlAlarmSystem(900), controlDeviceParameter(1000), fileUploadDownload(1100), factorySettings(2000), accountManagement(2100), northboundManagement(2200), connectivityManagement(2300), scheduler(2325), jobMonitor(2350), logManager(2375), coverageNetworkManagementGeneral(2400), coverageNetworkManagementConfiguration(2500), coverageNetworkManagementManualDelete(2550), coverageNetworkManagementMaintenance(2600), coverageNetworkManagementMapView(2630), coverageNetworkManagementManualClear(2660), coverageNetworkManagementSupervision(2700), coverageNetworkManagementTopology(2800), organizationProfilesManagement(2900), performanceManager(2925), reporting(2950), sessionManagement(3000), unitList(3100), watchDog(3200) }currentRightArea is an INTEGER used in order to indicate the controller right with the following named values: . factorySettings(2000) . accountManagement(2100) . northboundManagement(2200) . connectivityManagement(2300) . sch…
SDNOCTET STRING (SIZE (4..80))currentThe SDN is an OCTET STRING having up to 80 characters used in order to represent system distinguished names. Each character must be in range from 32 to 126 (' ' <space> to '~' <tilde>).
SerialNoOCTET STRING (SIZE (0..10))currentSerialNo is an OCTET STRING with up to 10 characters used in order to represent the Mikom Serial-No of the device.
SeverityINTEGER { indeterminate(0), critical(1), major(2), minor(3), warning(4), cleared(5), information(6) }currentSeverity is an INTEGER used in order to indicate the relative level of urgency for operator attention by the following named values: . indeterminate(0) . critical(1) . major(2) . minor(3) . warning(4) . cleared(5) . inf…
SpecificProblemUnsigned32 (0..9999)currentSpecificProblem is an Unsigned32 value within a range from 0 to 9.999 used in order to classify the fault situation as defined in ITU-T Recommendation X.733 clause 8.1.2.2.
SubRackIDUnsigned32 (1..124)currentSubRackID is an Unsigned32 value within the range from 1 to 124 used in order to represent the unique key for SubRack Master Units, each contained in one Master Unit and connected to some Remote Units.
SystemAvailabilityINTEGER { inaccessible(0), accessible(1), exclusiveAccessRequested(2), exclusiveAccess(3) }currentSystemAvailability is in later released versions of the agent needed for system backup and restore purposes. It has the syntax INTEGER with the following named values: . inaccessible(0) not used yet . accessible(1) logi…
TableIndexUnsigned32 (1..2147483647)currentTableIndex is an Unsigned32 value within the range from 1 to 2^32-1 used for table indexing.
TemperatureStatusInteger32 (-55..125)currentTemperatureStatus is an Unsigned32 value within the range from -55 to 125 used in order to represent the current temperature value in degrees centigrade.
TextOCTET STRING (SIZE (0..100))currentText is an OCTET STRING with up to 100 characters having each character in a range from 32 to 126 (' ' <space> to '~' <tilde>).
TimeDisplayFormatINTEGER { default(0), osiBinary(1), osiText(2), osiFormatted(3), snmpBinary(4), snmpText(5), snmpFormatted(6), windows(7) }currentTimeDisplayFormat is an INTEGER used in order to indicate of how date and time values are transmitted in objects of type VariableTime are encoded by the SNMP agent. This will be done using one of the following named val…
TimeFormatINTEGER { utcTimeFormat(0), localTimeFormat(1) }currentTimeFormat is an INTEGER used in order to indicate the time format for date and time values with the following named values: . utcTimeFormat(0) Coordinated Universal Time (UTC), also known as Greenwich Mean Time (GMT) .…
TrendIndicationINTEGER { lessSevere(0), noChange(1), moreSevere(2) }currentTrendIndication is an INTEGER used in order to indicate the ISO/IEC 10164-4, Chapter 8.1.2.6 conform trend indication of an alarm by the following named values: . lessSevere(0) . noChange(1) . moreSevere(2)
UnitReferenceUnsigned32 (1..2147483647)currentUnitReference is an Unsigned32 value that can be used for a system-wide unique identification of each individual unit. Contrary to this the textual conventions MasterID, SubRackID, RemoteID and NSOID only identify the c…
UserNameOCTET STRING (SIZE (1..40))currentUserName is an OCTET STRING having up to 40 characters used in order to represent uniquely user names. Each character must be in range from 32 to 126 (' ' <space> to '~' <tilde>).
UTCTimeOCTET STRING (SIZE (8))currentUTCTime is an OCTET STRING having 8 octets used in order to represent date and time values in UTC time format. This format consists of the following fields: field octets contents range 1 1-2 year 0..2999 2 3 month 1..12…
ValueSourceINTEGER { actualValue(1), cachedValue(2), desiredValue(3) }currentValueSource is an INTEGER used in order to indicate the value to be addressed with the following named values: . actualValue(1) the current value . cachedValue(2) the most recent read value . desiredValue(3) a desired v…
VariableTimeOCTET STRING (SIZE (0..28))currentVariableTime is an OCTET STRING with up to 28 characters used in order to represent date and time values. Two objects have influence on coding the values: . aimosTimeFormat specifies whether times are coded in UTC or in…
VersionOCTET STRING (SIZE (3..15))currentVersion is an OCTET STRING with at least 3 up to 13 characters in the format n.n.n.n (e.g. 1.0.5.328) denoting the hierarchical nested major and minor version, release, and build identification.
WeekMinutesUnsigned32 (0..10080)currentWeekMinutes is an Unsigned32 value within the range from 0 to 10.080 used in order to represent an amount of minutes for up to one week.