MIB Viewer

AISPY-MIB

400 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1NodeaiSPYAlarmEntryAddedAn AlarmEntryAdded Trap signifies that the a sensor reading has reached a high or low limit value.
1.3.6.1.4.1.539Nodeaii
1.3.6.1.4.1.539.20NodeaiSPY
1.3.6.1.4.1.539.20.1NodeaiSPYIdent
1.3.6.1.4.1.539.20.1.1ScalaraiSPYIdentManufacturerread-onlymandatoryThe Monitor Control Unit manufacturer.
1.3.6.1.4.1.539.20.1.2ScalaraiSPYIdentModelread-onlymandatoryThe Monitor Control Unit Model designation.
1.3.6.1.4.1.539.20.1.3ScalaraiSPYIdentSoftwareVersionread-onlymandatoryThe aiSPY SNMP Agent software version.
1.3.6.1.4.1.539.20.1.4ScalaraiSPYIdentSpecificread-onlymandatoryA reference to MIB definitions specific to the particular Monitor Unit being managed. This object is used to locate the product-specific MIB for this device. I…
1.3.6.1.4.1.539.20.2NodeaiSPYSystem
1.3.6.1.4.1.539.20.2.1ScalaraiSPYClockread-writemandatoryThe aiSPY internal clock settings. Displayed as MM/DD/YY HH:MM:SS
1.3.6.1.4.1.539.20.2.2ScalaraiSPYDoorAlarmBypassread-writemandatoryThe aiSPY door alarm bypass switch. This allows the alarm to be bypassed upon valid keypad access. Zero disables this, or use 1 thru 20 for the corresponding a…
1.3.6.1.4.1.539.20.2.3NodeaiSPYKeypad
1.3.6.1.4.1.539.20.2.3.1ScalaraiSPYKeypadCode1read-writemandatoryThe aiSPY keypad access code for user #1. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.2ScalaraiSPYKeypadName1read-writemandatoryThe aiSPY keypad access name for user #1. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.3ScalaraiSPYKeypadCode2read-writemandatoryThe aiSPY keypad access code for user #2. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.4ScalaraiSPYKeypadName2read-writemandatoryThe aiSPY keypad access name for user #2. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.5ScalaraiSPYKeypadCode3read-writemandatoryThe aiSPY keypad access code for user #3. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.6ScalaraiSPYKeypadName3read-writemandatoryThe aiSPY keypad access name for user #3. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.7ScalaraiSPYKeypadCode4read-writemandatoryThe aiSPY keypad access code for user #4. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.8ScalaraiSPYKeypadName4read-writemandatoryThe aiSPY keypad access name for user #4. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.9ScalaraiSPYKeypadCode5read-writemandatoryThe aiSPY keypad access code for user #5. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.10ScalaraiSPYKeypadName5read-writemandatoryThe aiSPY keypad access name for user #5. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.11ScalaraiSPYKeypadCode6read-writemandatoryThe aiSPY keypad access code for user #6. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.12ScalaraiSPYKeypadName6read-writemandatoryThe aiSPY keypad access name for user #6. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.13ScalaraiSPYKeypadCode7read-writemandatoryThe aiSPY keypad access code for user #7. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.14ScalaraiSPYKeypadName7read-writemandatoryThe aiSPY keypad access name for user #7. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.15ScalaraiSPYKeypadCode8read-writemandatoryThe aiSPY keypad access code for user #8. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.16ScalaraiSPYKeypadName8read-writemandatoryThe aiSPY keypad access name for user #8. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.17ScalaraiSPYKeypadCode9read-writemandatoryThe aiSPY keypad access code for user #9. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.18ScalaraiSPYKeypadName9read-writemandatoryThe aiSPY keypad access name for user #9. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.19ScalaraiSPYKeypadCode10read-writemandatoryThe aiSPY keypad access code for user #10. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.20ScalaraiSPYKeypadName10read-writemandatoryThe aiSPY keypad access name for user #10. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.21ScalaraiSPYKeypadCode11read-writemandatoryThe aiSPY keypad access code for user #11. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.22ScalaraiSPYKeypadName11read-writemandatoryThe aiSPY keypad access name for user #11. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.23ScalaraiSPYKeypadCode12read-writemandatoryThe aiSPY keypad access code for user #12. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.24ScalaraiSPYKeypadName12read-writemandatoryThe aiSPY keypad access name for user #12. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.25ScalaraiSPYKeypadCode13read-writemandatoryThe aiSPY keypad access code for user #13. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.26ScalaraiSPYKeypadName13read-writemandatoryThe aiSPY keypad access name for user #13. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.27ScalaraiSPYKeypadCode14read-writemandatoryThe aiSPY keypad access code for user #14. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.28ScalaraiSPYKeypadName14read-writemandatoryThe aiSPY keypad access name for user #14. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.29ScalaraiSPYKeypadCode15read-writemandatoryThe aiSPY keypad access code for user #15. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.30ScalaraiSPYKeypadName15read-writemandatoryThe aiSPY keypad access name for user #15. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.31ScalaraiSPYKeypadCode16read-writemandatoryThe aiSPY keypad access code for user #16. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.32ScalaraiSPYKeypadName16read-writemandatoryThe aiSPY keypad access name for user #16. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.33ScalaraiSPYKeypadCode17read-writemandatoryThe aiSPY keypad access code for user #17. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.34ScalaraiSPYKeypadName17read-writemandatoryThe aiSPY keypad access name for user #17. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.35ScalaraiSPYKeypadCode18read-writemandatoryThe aiSPY keypad access code for user #18. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.36ScalaraiSPYKeypadName18read-writemandatoryThe aiSPY keypad access name for user #18. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.37ScalaraiSPYKeypadCode19read-writemandatoryThe aiSPY keypad access code for user #19. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.38ScalaraiSPYKeypadName19read-writemandatoryThe aiSPY keypad access name for user #19. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.3.39ScalaraiSPYKeypadCode20read-writemandatoryThe aiSPY keypad access code for user #20. This can be up to six numeric characters.
1.3.6.1.4.1.539.20.2.3.40ScalaraiSPYKeypadName20read-writemandatoryThe aiSPY keypad access name for user #20. This can be up to 20 characters.
1.3.6.1.4.1.539.20.2.4ScalaraiSPYInputVoltageread-onlymandatoryThe aiSPY input voltage (DC Power).
1.3.6.1.4.1.539.20.2.5ScalaraiSPYOnBatteryread-writemandatoryThe state of use of the On Battery Alarm. When the State is set to installed(1), the On Battery and Low Battery alarms are enabled. This variable is stored in …
1.3.6.1.4.1.539.20.2.6ScalaraiSPYLowBatteryThresholdread-writemandatoryThe low voltage trip point for the low battery alarm. When the input voltage goes below this voltage, the Low Battery alarm is set. This variable is stored in …
1.3.6.1.4.1.539.20.2.7ScalaraiSPYAnalogAverageread-writemandatoryThis is the analog averaging duration in seconds. The analog input readings are averaged for this time period before updating. This value must be set to 1,2,3,…
1.3.6.1.4.1.539.20.3NodeaiSPY8124
1.3.6.1.4.1.539.20.3NodeaiSPYInputs
1.3.6.1.4.1.539.20.3.1NodeaiSPYInput1
1.3.6.1.4.1.539.20.3.1.1ScalaraiSPYInput1Stateread-writemandatoryThe state of use of Input Number 1. When a sensor is connected to Input 1 set State to installed(2) to indicate that the value of aiSPYReading1 is valid. When …
1.3.6.1.4.1.539.20.3.1.2ScalaraiSPYInput1Readingread-onlymandatoryThe reading for sensor 1. If the input is digital, the reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.1.3ScalaraiSPYInput1Gainread-writemandatoryA correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 1 to obtain the value of the Input…
1.3.6.1.4.1.539.20.3.1.4ScalaraiSPYInput1Offsetread-writemandatoryA correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 1 to obtain the value of the Input1…
1.3.6.1.4.1.539.20.3.1.5ScalaraiSPYInput1Labelread-writemandatoryA user-defined text string associated with Input Number 1. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.1.6ScalaraiSPYInput1UOMread-writemandatoryA user-defined text string associated with Input Number 1. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.1.7ScalaraiSPYInput1HighLimitread-writemandatoryWhen input 1 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 1. The HighLimit variable is stored in non-vola…
1.3.6.1.4.1.539.20.3.1.8ScalaraiSPYInput1LowLimitread-writemandatoryWhen input 1 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 1. The LowLimit variable is stored in non-vol…
1.3.6.1.4.1.539.20.3.1.9ScalaraiSPYInput1RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.1.10ScalaraiSPYInput1Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.1.11ScalaraiSPYInput1RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.1.12ScalaraiSPYInput1Hysteresisread-writemandatoryThe value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in…
1.3.6.1.4.1.539.20.3.2NodeaiSPYInput2
1.3.6.1.4.1.539.20.3.2.1ScalaraiSPYInput2Stateread-writemandatoryThe state of use of Input Number 2. When a sensor is connected to Input 2 set State to installed(2) to indicate that the value of aiSPYReading2 is valid. When …
1.3.6.1.4.1.539.20.3.2.2ScalaraiSPYInput2Readingread-onlymandatoryThe reading for sensor 2. If the input is digital, the reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.2.3ScalaraiSPYInput2Gainread-writemandatoryA correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 2 to obtain the value of the Input…
1.3.6.1.4.1.539.20.3.2.4ScalaraiSPYInput2Offsetread-writemandatoryA correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 2 to obtain the value of the Input2…
1.3.6.1.4.1.539.20.3.2.5ScalaraiSPYInput2Labelread-writemandatoryA user-defined text string associated with Input Number 2. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.2.6ScalaraiSPYInput2UOMread-writemandatoryA user-defined text string associated with Input Number 2. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.2.7ScalaraiSPYInput2HighLimitread-writemandatoryWhen input 2 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 2. The HighLimit variable is stored in non-vola…
1.3.6.1.4.1.539.20.3.2.8ScalaraiSPYInput2LowLimitread-writemandatoryWhen input 2 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 2. The LowLimit variable is stored in non-vol…
1.3.6.1.4.1.539.20.3.2.9ScalaraiSPYInput2RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.2.10ScalaraiSPYInput2Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.2.11ScalaraiSPYInput2RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.2.12ScalaraiSPYInput2Hysteresisread-writemandatoryThe value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in…
1.3.6.1.4.1.539.20.3.3NodeaiSPYInput3
1.3.6.1.4.1.539.20.3.3.1ScalaraiSPYInput3Stateread-writemandatoryThe state of use of Input Number 3. When a sensor is connected to Input 3 set State to installed(2) to indicate that the value of aiSPYReading3 is valid. When …
1.3.6.1.4.1.539.20.3.3.2ScalaraiSPYInput3Readingread-onlymandatoryThe reading for sensor 3. If the input is digital, the reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.3.3ScalaraiSPYInput3Gainread-writemandatoryA correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 3 to obtain the value of the Input…
1.3.6.1.4.1.539.20.3.3.4ScalaraiSPYInput3Offsetread-writemandatoryA correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 3 to obtain the value of the Input3…
1.3.6.1.4.1.539.20.3.3.5ScalaraiSPYInput3Labelread-writemandatoryA user-defined text string associated with Input Number 3. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.3.6ScalaraiSPYInput3UOMread-writemandatoryA user-defined text string associated with Input Number 3. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.3.7ScalaraiSPYInput3HighLimitread-writemandatoryWhen input 3 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 3. The HighLimit variable is stored in non-vola…
1.3.6.1.4.1.539.20.3.3.8ScalaraiSPYInput3LowLimitread-writemandatoryWhen input 3 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 3. The LowLimit variable is stored in non-vol…
1.3.6.1.4.1.539.20.3.3.9ScalaraiSPYInput3RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.3.10ScalaraiSPYInput3Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.3.11ScalaraiSPYInput3RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.3.12ScalaraiSPYInput3Hysteresisread-writemandatoryThe value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in…
1.3.6.1.4.1.539.20.3.4NodeaiSPYInput4
1.3.6.1.4.1.539.20.3.4.1ScalaraiSPYInput4Stateread-writemandatoryThe state of use of Input Number 4. When a sensor is connected to Input 4 set State to installed(2) to indicate that the value of aiSPYReading4 is valid. When …
1.3.6.1.4.1.539.20.3.4.2ScalaraiSPYInput4Readingread-onlymandatoryThe reading for sensor 4. If the input is digital, the reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.4.3ScalaraiSPYInput4Gainread-writemandatoryA correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 4 to obtain the value of the Input…
1.3.6.1.4.1.539.20.3.4.4ScalaraiSPYInput4Offsetread-writemandatoryA correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 4 to obtain the value of the Input4…
1.3.6.1.4.1.539.20.3.4.5ScalaraiSPYInput4Labelread-writemandatoryA user-defined text string associated with Input Number 4. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.4.6ScalaraiSPYInput4UOMread-writemandatoryA user-defined text string associated with Input Number 4. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.4.7ScalaraiSPYInput4HighLimitread-writemandatoryWhen input 4 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 4. The HighLimit variable is stored in non-vola…
1.3.6.1.4.1.539.20.3.4.8ScalaraiSPYInput4LowLimitread-writemandatoryWhen input 4 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 4. The LowLimit variable is stored in non-vol…
1.3.6.1.4.1.539.20.3.4.9ScalaraiSPYInput4RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.4.10ScalaraiSPYInput4Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.4.11ScalaraiSPYInput4RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.4.12ScalaraiSPYInput4Hysteresisread-writemandatoryThe value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in…
1.3.6.1.4.1.539.20.3.5NodeaiSPYInput5
1.3.6.1.4.1.539.20.3.5.1ScalaraiSPYInput5Stateread-writemandatoryThe state of use of Input Number 5. When a sensor is connected to Input 5 set State to installed(2) to indicate that the value of aiSPYReading4 is valid. When …
1.3.6.1.4.1.539.20.3.5.2ScalaraiSPYInput5Readingread-onlymandatoryThe reading for sensor 5. If the input is digital, the reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.5.3ScalaraiSPYInput5Gainread-writemandatoryA correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 5 to obtain the value of the Input…
1.3.6.1.4.1.539.20.3.5.4ScalaraiSPYInput5Offsetread-writemandatoryA correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 5 to obtain the value of the Input5…
1.3.6.1.4.1.539.20.3.5.5ScalaraiSPYInput5Labelread-writemandatoryA user-defined text string associated with Input Number 5. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.5.6ScalaraiSPYInput5UOMread-writemandatoryA user-defined text string associated with Input Number 5. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.5.7ScalaraiSPYInput5HighLimitread-writemandatoryWhen input 5 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 5. The HighLimit variable is stored in non-vola…
1.3.6.1.4.1.539.20.3.5.8ScalaraiSPYInput5LowLimitread-writemandatoryWhen input 5 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 5. The LowLimit variable is stored in non-vol…
1.3.6.1.4.1.539.20.3.5.9ScalaraiSPYInput5RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.5.10ScalaraiSPYInput5Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.5.11ScalaraiSPYInput5RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.5.12ScalaraiSPYInput5Hysteresisread-writemandatoryThe value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in…
1.3.6.1.4.1.539.20.3.6NodeaiSPYInput6
1.3.6.1.4.1.539.20.3.6.1ScalaraiSPYInput6Stateread-writemandatoryThe state of use of Input Number 6. When a sensor is connected to Input 6 set State to installed(2) to indicate that the value of aiSPYReading6 is valid. When …
1.3.6.1.4.1.539.20.3.6.2ScalaraiSPYInput6Readingread-onlymandatoryThe reading for sensor 6. If the input is digital, the reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.6.3ScalaraiSPYInput6Gainread-writemandatoryA correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 6 to obtain the value of the Input…
1.3.6.1.4.1.539.20.3.6.4ScalaraiSPYInput6Offsetread-writemandatoryA correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 6 to obtain the value of the Input6…
1.3.6.1.4.1.539.20.3.6.5ScalaraiSPYInput6Labelread-writemandatoryA user-defined text string associated with Input Number 6. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.6.6ScalaraiSPYInput6UOMread-writemandatoryA user-defined text string associated with Input Number 6. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.6.7ScalaraiSPYInput6HighLimitread-writemandatoryWhen input 6 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 6. The HighLimit variable is stored in non-vola…
1.3.6.1.4.1.539.20.3.6.8ScalaraiSPYInput6LowLimitread-writemandatoryWhen input 6 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 6. The LowLimit variable is stored in non-vol…
1.3.6.1.4.1.539.20.3.6.9ScalaraiSPYInput6RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.6.10ScalaraiSPYInput6Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.6.11ScalaraiSPYInput6RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.6.12ScalaraiSPYInput6Hysteresisread-writemandatoryThe value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in…
1.3.6.1.4.1.539.20.3.7NodeaiSPYInput7
1.3.6.1.4.1.539.20.3.7.1ScalaraiSPYInput7Stateread-writemandatoryThe state of use of Input Number 7. When a sensor is connected to Input 7 set State to installed(2) to indicate that the value of aiSPYReading4 is valid. When …
1.3.6.1.4.1.539.20.3.7.2ScalaraiSPYInput7Readingread-onlymandatoryThe reading for sensor 7. If the input is digital, the reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.7.3ScalaraiSPYInput7Gainread-writemandatoryA correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 7 to obtain the value of the Input…
1.3.6.1.4.1.539.20.3.7.4ScalaraiSPYInput7Offsetread-writemandatoryA correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 7 to obtain the value of the Input7…
1.3.6.1.4.1.539.20.3.7.5ScalaraiSPYInput7Labelread-writemandatoryA user-defined text string associated with Input Number 7. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.7.6ScalaraiSPYInput7UOMread-writemandatoryA user-defined text string associated with Input Number 7. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.7.7ScalaraiSPYInput7HighLimitread-writemandatoryWhen input 7 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 7. The HighLimit variable is stored in non-vola…
1.3.6.1.4.1.539.20.3.7.8ScalaraiSPYInput7LowLimitread-writemandatoryWhen input 7 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 7. The LowLimit variable is stored in non-vol…
1.3.6.1.4.1.539.20.3.7.9ScalaraiSPYInput7RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.7.10ScalaraiSPYInput7Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.7.11ScalaraiSPYInput7RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.7.12ScalaraiSPYInput7Hysteresisread-writemandatoryThe value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in…
1.3.6.1.4.1.539.20.3.8NodeaiSPYInput8
1.3.6.1.4.1.539.20.3.8.1ScalaraiSPYInput8Stateread-writemandatoryThe state of use of Input Number 8. When a sensor is connected to Input 8 set State to installed(2) to indicate that the value of aiSPYReading8 is valid. When …
1.3.6.1.4.1.539.20.3.8.2ScalaraiSPYInput8Readingread-onlymandatoryThe reading for sensor 8. If the input is digital, the reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.8.3ScalaraiSPYInput8Gainread-writemandatoryA correction gain associated with the sensor variable. The value of gain is multiplied by the value from Input Sensor Number 8 to obtain the value of the Input…
1.3.6.1.4.1.539.20.3.8.4ScalaraiSPYInput8Offsetread-writemandatoryA correction Offset associated with the sensor variable. The value of Offset is added to the value from Input Sensor Number 8 to obtain the value of the Input8…
1.3.6.1.4.1.539.20.3.8.5ScalaraiSPYInput8Labelread-writemandatoryA user-defined text string associated with Input Number 8. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.8.6ScalaraiSPYInput8UOMread-writemandatoryA user-defined text string associated with Input Number 8. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.8.7ScalaraiSPYInput8HighLimitread-writemandatoryWhen input 8 reaches or exceeds this value a trap will be generated signifying a high alarm condition at sensor 8. The HighLimit variable is stored in non-vola…
1.3.6.1.4.1.539.20.3.8.8ScalaraiSPYInput8LowLimitread-writemandatoryWhen input 8 reaches or goes below this value a trap will be generated signifying a low alarm condition at sensor 8. The LowLimit variable is stored in non-vol…
1.3.6.1.4.1.539.20.3.8.9ScalaraiSPYInput8RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.8.10ScalaraiSPYInput8Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.8.11ScalaraiSPYInput8RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.8.12ScalaraiSPYInput8Hysteresisread-writemandatoryThe value of alarm hysteresis for this input. The input reading must decrease or increase by this value before the alarm will clear. This variable is stored in…
1.3.6.1.4.1.539.20.3.25NodeaiSPYInput9
1.3.6.1.4.1.539.20.3.25.1ScalaraiSPYInput9Stateread-writemandatoryThe state of use of Input Number 9. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.25.2ScalaraiSPYInput9Readingread-onlymandatoryThe reading for input 9. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.25.3ScalaraiSPYInput9Labelread-writemandatoryA user-defined text string associated with Input Number 9. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.25.4ScalaraiSPYInput9RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.25.5ScalaraiSPYInput9Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.25.6ScalaraiSPYInput9RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.26NodeaiSPYInput10
1.3.6.1.4.1.539.20.3.26.1ScalaraiSPYInput10Stateread-writemandatoryThe state of use of Input Number 10. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.26.2ScalaraiSPYInput10Readingread-onlymandatoryThe reading for input 10. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.26.3ScalaraiSPYInput10Labelread-writemandatoryA user-defined text string associated with Input Number 10. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.26.4ScalaraiSPYInput10RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.26.5ScalaraiSPYInput10Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.26.6ScalaraiSPYInput10RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.27NodeaiSPYInput11
1.3.6.1.4.1.539.20.3.27.1ScalaraiSPYInput11Stateread-writemandatoryThe state of use of Input Number 11. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.27.2ScalaraiSPYInput11Readingread-onlymandatoryThe reading for input 11. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.27.3ScalaraiSPYInput11Labelread-writemandatoryA user-defined text string associated with Input Number 11. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.27.4ScalaraiSPYInput11RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.27.5ScalaraiSPYInput11Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.27.6ScalaraiSPYInput11RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.28NodeaiSPYInput12
1.3.6.1.4.1.539.20.3.28.1ScalaraiSPYInput12Stateread-writemandatoryThe state of use of Input Number 12. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.28.2ScalaraiSPYInput12Readingread-onlymandatoryThe reading for input 12. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.28.3ScalaraiSPYInput12Labelread-writemandatoryA user-defined text string associated with Input Number 12. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.28.4ScalaraiSPYInput12RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.28.5ScalaraiSPYInput12Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.28.6ScalaraiSPYInput12RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.29NodeaiSPYInput13
1.3.6.1.4.1.539.20.3.29.1ScalaraiSPYInput13Stateread-writemandatoryThe state of use of Input Number 13. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.29.2ScalaraiSPYInput13Readingread-onlymandatoryThe reading for input 13. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.29.3ScalaraiSPYInput13Labelread-writemandatoryA user-defined text string associated with Input Number 13. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.29.4ScalaraiSPYInput13RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.29.5ScalaraiSPYInput13Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.29.6ScalaraiSPYInput13RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.30NodeaiSPYInput14
1.3.6.1.4.1.539.20.3.30.1ScalaraiSPYInput14Stateread-writemandatoryThe state of use of Input Number 14. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.30.2ScalaraiSPYInput14Readingread-onlymandatoryThe reading for input 14. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.30.3ScalaraiSPYInput14Labelread-writemandatoryA user-defined text string associated with Input Number 14. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.30.4ScalaraiSPYInput14RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.30.5ScalaraiSPYInput14Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.30.6ScalaraiSPYInput14RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.31NodeaiSPYInput15
1.3.6.1.4.1.539.20.3.31.1ScalaraiSPYInput15Stateread-writemandatoryThe state of use of Input Number 15. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.31.2ScalaraiSPYInput15Readingread-onlymandatoryThe reading for input 15. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.31.3ScalaraiSPYInput15Labelread-writemandatoryA user-defined text string associated with Input Number 15. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.31.4ScalaraiSPYInput15RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.31.5ScalaraiSPYInput15Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.31.6ScalaraiSPYInput15RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.32NodeaiSPYInput16
1.3.6.1.4.1.539.20.3.32.1ScalaraiSPYInput16Stateread-writemandatoryThe state of use of Input Number 16. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.32.2ScalaraiSPYInput16Readingread-onlymandatoryThe reading for input 16. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.32.3ScalaraiSPYInput16Labelread-writemandatoryA user-defined text string associated with Input Number 16. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.32.4ScalaraiSPYInput16RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.32.5ScalaraiSPYInput16Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.32.6ScalaraiSPYInput16RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.33NodeaiSPYInput17
1.3.6.1.4.1.539.20.3.33.1ScalaraiSPYInput17Stateread-writemandatoryThe state of use of Input Number 17. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.33.2ScalaraiSPYInput17Readingread-onlymandatoryThe reading for input 17. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.33.3ScalaraiSPYInput17Labelread-writemandatoryA user-defined text string associated with Input Number 17. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.33.4ScalaraiSPYInput17RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.33.5ScalaraiSPYInput17Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.33.6ScalaraiSPYInput17RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.34NodeaiSPYInput18
1.3.6.1.4.1.539.20.3.34.1ScalaraiSPYInput18Stateread-writemandatoryThe state of use of Input Number 18. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.34.2ScalaraiSPYInput18Readingread-onlymandatoryThe reading for input 18. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.34.3ScalaraiSPYInput18Labelread-writemandatoryA user-defined text string associated with Input Number 18. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.34.4ScalaraiSPYInput18RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.34.5ScalaraiSPYInput18Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.34.6ScalaraiSPYInput18RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.35NodeaiSPYInput19
1.3.6.1.4.1.539.20.3.35.1ScalaraiSPYInput19Stateread-writemandatoryThe state of use of Input Number 19. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.35.2ScalaraiSPYInput19Readingread-onlymandatoryThe reading for input 19. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.35.3ScalaraiSPYInput19Labelread-writemandatoryA user-defined text string associated with Input Number 19. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.35.4ScalaraiSPYInput19RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.35.5ScalaraiSPYInput19Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.35.6ScalaraiSPYInput19RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.36NodeaiSPYInput20
1.3.6.1.4.1.539.20.3.36.1ScalaraiSPYInput20Stateread-writemandatoryThe state of use of Input Number 20. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.36.2ScalaraiSPYInput20Readingread-onlymandatoryThe reading for input 20. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.36.3ScalaraiSPYInput20Labelread-writemandatoryA user-defined text string associated with Input Number 20. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.36.4ScalaraiSPYInput20RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.36.5ScalaraiSPYInput20Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.36.6ScalaraiSPYInput20RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.37NodeaiSPYInput21
1.3.6.1.4.1.539.20.3.37.1ScalaraiSPYInput21Stateread-writemandatoryThe state of use of Input Number 21. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.37.2ScalaraiSPYInput21Readingread-onlymandatoryThe reading for input 21. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.37.3ScalaraiSPYInput21Labelread-writemandatoryA user-defined text string associated with Input Number 21. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.37.4ScalaraiSPYInput21RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.37.5ScalaraiSPYInput21Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.37.6ScalaraiSPYInput21RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.38NodeaiSPYInput22
1.3.6.1.4.1.539.20.3.38.1ScalaraiSPYInput22Stateread-writemandatoryThe state of use of Input Number 22. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.38.2ScalaraiSPYInput22Readingread-onlymandatoryThe reading for input 22. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.38.3ScalaraiSPYInput22Labelread-writemandatoryA user-defined text string associated with Input Number 22. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.38.4ScalaraiSPYInput22RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.38.5ScalaraiSPYInput22Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.38.6ScalaraiSPYInput22RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.39NodeaiSPYInput23
1.3.6.1.4.1.539.20.3.39.1ScalaraiSPYInput23Stateread-writemandatoryThe state of use of Input Number 23. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.39.2ScalaraiSPYInput23Readingread-onlymandatoryThe reading for input 23. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.39.3ScalaraiSPYInput23Labelread-writemandatoryA user-defined text string associated with Input Number 23. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.39.4ScalaraiSPYInput23RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.39.5ScalaraiSPYInput23Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.39.6ScalaraiSPYInput23RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.40NodeaiSPYInput24
1.3.6.1.4.1.539.20.3.40.1ScalaraiSPYInput24Stateread-writemandatoryThe state of use of Input Number 24. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.40.2ScalaraiSPYInput24Readingread-onlymandatoryThe reading for input 24. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.40.3ScalaraiSPYInput24Labelread-writemandatoryA user-defined text string associated with Input Number 24. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.40.4ScalaraiSPYInput24RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.40.5ScalaraiSPYInput24Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.40.6ScalaraiSPYInput24RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.41NodeaiSPYInput25
1.3.6.1.4.1.539.20.3.41.1ScalaraiSPYInput25Stateread-writemandatoryThe state of use of Input Number 25. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.41.2ScalaraiSPYInput25Readingread-onlymandatoryThe reading for input 25. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.41.3ScalaraiSPYInput25Labelread-writemandatoryA user-defined text string associated with Input Number 25. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.41.4ScalaraiSPYInput25RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.41.5ScalaraiSPYInput25Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.41.6ScalaraiSPYInput25RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.42NodeaiSPYInput26
1.3.6.1.4.1.539.20.3.42.1ScalaraiSPYInput26Stateread-writemandatoryThe state of use of Input Number 26. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.42.2ScalaraiSPYInput26Readingread-onlymandatoryThe reading for input 26. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.42.3ScalaraiSPYInput26Labelread-writemandatoryA user-defined text string associated with Input Number 26. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.42.4ScalaraiSPYInput26RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.42.5ScalaraiSPYInput26Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.42.6ScalaraiSPYInput26RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.43NodeaiSPYInput27
1.3.6.1.4.1.539.20.3.43.1ScalaraiSPYInput27Stateread-writemandatoryThe state of use of Input Number 27. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.43.2ScalaraiSPYInput27Readingread-onlymandatoryThe reading for input 27. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.43.3ScalaraiSPYInput27Labelread-writemandatoryA user-defined text string associated with Input Number 27. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.43.4ScalaraiSPYInput27RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.43.5ScalaraiSPYInput27Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.43.6ScalaraiSPYInput27RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.3.44NodeaiSPYInput28
1.3.6.1.4.1.539.20.3.44.1ScalaraiSPYInput28Stateread-writemandatoryThe state of use of Input Number 28. This variable is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.44.2ScalaraiSPYInput28Readingread-onlymandatoryThe reading for input 28. The reading will be 1 (active) or 0 (inactive)
1.3.6.1.4.1.539.20.3.44.3ScalaraiSPYInput28Labelread-writemandatoryA user-defined text string associated with Input Number 28. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.3.44.4ScalaraiSPYInput28RlyControlread-writemandatoryThe control of the output relays. This is a binary setting with each bit representing an alarm state. To set K1 on a high alarm, set the 1st bit (1). To set K2…
1.3.6.1.4.1.539.20.3.44.5ScalaraiSPYInput28Delayread-writemandatoryThe number of seconds an alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-volatile…
1.3.6.1.4.1.539.20.3.44.6ScalaraiSPYInput28RTNDelayread-writemandatoryThe number of seconds a cleared alarm for this input must be present before annunication. The range of this setting is 0..600. This variable is stored in non-v…
1.3.6.1.4.1.539.20.4NodeaiSPYOutputs
1.3.6.1.4.1.539.20.4.1NodeaiSPYRelay1
1.3.6.1.4.1.539.20.4.1.1ScalaraiSPYRelay1Stateread-writemandatoryThe state of use of Relay Number 1. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the k…
1.3.6.1.4.1.539.20.4.1.2ScalaraiSPYRelay1Statusread-onlymandatoryThe current status for relay 1.
1.3.6.1.4.1.539.20.4.1.3ScalaraiSPYRelay1Labelread-writemandatoryA user-defined text string associated with Relay Number 1. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.4.1.4ScalaraiSPYRelay1Timeread-writemandatoryThe number of seconds the relay will be activated. Set this to -1 for indefinitely.
1.3.6.1.4.1.539.20.4.2NodeaiSPYRelay2
1.3.6.1.4.1.539.20.4.2.1ScalaraiSPYRelay2Stateread-writemandatoryThe state of use of Relay Number 2. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the k…
1.3.6.1.4.1.539.20.4.2.2ScalaraiSPYRelay2Statusread-onlymandatoryThe current status for relay 2.
1.3.6.1.4.1.539.20.4.2.3ScalaraiSPYRelay2Labelread-writemandatoryA user-defined text string associated with Relay Number 2. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.4.2.4ScalaraiSPYRelay2Timeread-writemandatoryThe number of seconds the relay will be activated. Set this to -1 for indefinitely.
1.3.6.1.4.1.539.20.4.3NodeaiSPYRelay3
1.3.6.1.4.1.539.20.4.3.1ScalaraiSPYRelay3Stateread-writemandatoryThe state of use of Relay Number 3. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the k…
1.3.6.1.4.1.539.20.4.3.2ScalaraiSPYRelay3Statusread-onlymandatoryThe current status for relay 3.
1.3.6.1.4.1.539.20.4.3.3ScalaraiSPYRelay3Labelread-writemandatoryA user-defined text string associated with Relay Number 3. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.4.3.4ScalaraiSPYRelay3Timeread-writemandatoryThe number of seconds the relay will be activated. Set this to -1 for indefinitely.
1.3.6.1.4.1.539.20.4.4NodeaiSPYRelay4
1.3.6.1.4.1.539.20.4.4.1ScalaraiSPYRelay4Stateread-writemandatoryThe state of use of Relay Number 4. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the k…
1.3.6.1.4.1.539.20.4.4.2ScalaraiSPYRelay4Statusread-onlymandatoryThe current status for relay 4.
1.3.6.1.4.1.539.20.4.4.3ScalaraiSPYRelay4Labelread-writemandatoryA user-defined text string associated with Relay Number 4. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.4.4.4ScalaraiSPYRelay4Timeread-writemandatoryThe number of seconds the relay will be activated. Set this to -1 for indefinitely.
1.3.6.1.4.1.539.20.4.5NodeaiSPYRelay5
1.3.6.1.4.1.539.20.4.5.1ScalaraiSPYRelay5Stateread-writemandatoryThe state of use of Relay Number 5. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the k…
1.3.6.1.4.1.539.20.4.5.2ScalaraiSPYRelay5Statusread-onlymandatoryThe current status for relay 5.
1.3.6.1.4.1.539.20.4.5.3ScalaraiSPYRelay5Labelread-writemandatoryA user-defined text string associated with Relay Number 5. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.4.5.4ScalaraiSPYRelay5Timeread-writemandatoryThe number of seconds the relay will be activated. Set this to -1 for indefinitely.
1.3.6.1.4.1.539.20.4.6NodeaiSPYRelay6
1.3.6.1.4.1.539.20.4.6.1ScalaraiSPYRelay6Stateread-writemandatoryThe state of use of Relay Number 6. The relay can be set for normally open or closed. The relay can be forced to an on or off condition, or controlled by the k…
1.3.6.1.4.1.539.20.4.6.2ScalaraiSPYRelay6Statusread-onlymandatoryThe current status for relay 6.
1.3.6.1.4.1.539.20.4.6.3ScalaraiSPYRelay6Labelread-writemandatoryA user-defined text string associated with Relay Number 6. The text string is stored in non-volatile memory.
1.3.6.1.4.1.539.20.4.6.4ScalaraiSPYRelay6Timeread-writemandatoryThe number of seconds the relay will be activated. Set this to -1 for indefinitely.
1.3.6.1.4.1.539.20.5NodeaiSPYAlarms
1.3.6.1.4.1.539.20.5.1ScalaraiSPYAlarmsPresentread-onlycurrentThe present number of active alarm conditions.
1.3.6.1.4.1.539.20.5.2TableaiSPYAlarmTablenot-accessiblecurrentA list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is …
1.3.6.1.4.1.539.20.5.2.1RowaiSPYAlarmEntrynot-accessiblecurrentAn entry containing information applicable to a particular alarm.
1.3.6.1.4.1.539.20.5.2.1.1ColumnaiSPYAlarmIdnot-accessiblecurrentA unique identifier for an alarm condition. This value must remain constant.
1.3.6.1.4.1.539.20.5.2.1.2ColumnaiSPYAlarmDescrread-onlycurrentA reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm con…
1.3.6.1.4.1.539.20.5.3NodeaiSPYWellKnownAlarms
1.3.6.1.4.1.539.20.5.3.1IdentityaiSPYInput1HighAlarmcurrentThe reading for sensor 1 has reached the high limit value.
1.3.6.1.4.1.539.20.5.3.2IdentityaiSPYInput1LowAlarmcurrentThe reading for sensor 1 has reached the low limit value.
1.3.6.1.4.1.539.20.5.3.3IdentityaiSPYInput2HighAlarmcurrentThe reading for sensor 2 has reached the high limit value.
1.3.6.1.4.1.539.20.5.3.4IdentityaiSPYInput2LowAlarmcurrentThe reading for sensor 2 has reached the low limit value.
1.3.6.1.4.1.539.20.5.3.5IdentityaiSPYInput3HighAlarmcurrentThe reading for sensor 3 has reached the high limit value.
1.3.6.1.4.1.539.20.5.3.6IdentityaiSPYInput3LowAlarmcurrentThe reading for sensor 3 has reached the low limit value.
1.3.6.1.4.1.539.20.5.3.7IdentityaiSPYInput4HighAlarmcurrentThe reading for sensor 4 has reached the high limit value.
1.3.6.1.4.1.539.20.5.3.8IdentityaiSPYInput4LowAlarmcurrentThe reading for sensor 4 has reached the low limit value.
1.3.6.1.4.1.539.20.5.3.9IdentityaiSPYInput5HighAlarmcurrentThe reading for sensor 5 has reached the high limit value.
1.3.6.1.4.1.539.20.5.3.10IdentityaiSPYInput5LowAlarmcurrentThe reading for sensor 5 has reached the low limit value.
1.3.6.1.4.1.539.20.5.3.11IdentityaiSPYInput6HighAlarmcurrentThe reading for sensor 6 has reached the high limit value.
1.3.6.1.4.1.539.20.5.3.12IdentityaiSPYInput6LowAlarmcurrentThe reading for sensor 6 has reached the low limit value.
1.3.6.1.4.1.539.20.5.3.13IdentityaiSPYInput7HighAlarmcurrentThe reading for sensor 7 has reached the high limit value.
1.3.6.1.4.1.539.20.5.3.14IdentityaiSPYInput7LowAlarmcurrentThe reading for sensor 7 has reached the low limit value.
1.3.6.1.4.1.539.20.5.3.15IdentityaiSPYInput8HighAlarmcurrentThe reading for sensor 8 has reached the high limit value.
1.3.6.1.4.1.539.20.5.3.16IdentityaiSPYInput8LowAlarmcurrentThe reading for sensor 8 has reached the low limit value.
1.3.6.1.4.1.539.20.5.3.17IdentityaiSPYInput1DigAlarmcurrentThe digital input 1 has been activated.
1.3.6.1.4.1.539.20.5.3.18IdentityaiSPYInput2DigAlarmcurrentThe digital input 2 has been activated.
1.3.6.1.4.1.539.20.5.3.19IdentityaiSPYInput3DigAlarmcurrentThe digital input 3 has been activated.
1.3.6.1.4.1.539.20.5.3.20IdentityaiSPYInput4DigAlarmcurrentThe digital input 4 has been activated.
1.3.6.1.4.1.539.20.5.3.21IdentityaiSPYInput5DigAlarmcurrentThe digital input 5 has been activated.
1.3.6.1.4.1.539.20.5.3.22IdentityaiSPYInput6DigAlarmcurrentThe digital input 6 has been activated.
1.3.6.1.4.1.539.20.5.3.23IdentityaiSPYInput7DigAlarmcurrentThe digital input 7 has been activated.
1.3.6.1.4.1.539.20.5.3.24IdentityaiSPYInput8DigAlarmcurrentThe digital input 8 has been activated.
1.3.6.1.4.1.539.20.5.3.25IdentityaiSPYInput9DigAlarmcurrentThe digital input 9 has been activated.
1.3.6.1.4.1.539.20.5.3.26IdentityaiSPYInput10DigAlarmcurrentThe digital input 10 has been activated.
1.3.6.1.4.1.539.20.5.3.27IdentityaiSPYInput11DigAlarmcurrentThe digital input 11 has been activated.
1.3.6.1.4.1.539.20.5.3.28IdentityaiSPYInput12DigAlarmcurrentThe digital input 12 has been activated.
1.3.6.1.4.1.539.20.5.3.29IdentityaiSPYInput13DigAlarmcurrentThe digital input 13 has been activated.
1.3.6.1.4.1.539.20.5.3.30IdentityaiSPYInput14DigAlarmcurrentThe digital input 14 has been activated.
1.3.6.1.4.1.539.20.5.3.31IdentityaiSPYInput15DigAlarmcurrentThe digital input 15 has been activated.
1.3.6.1.4.1.539.20.5.3.32IdentityaiSPYInput16DigAlarmcurrentThe digital input 16 has been activated.
1.3.6.1.4.1.539.20.5.3.33IdentityaiSPYInput17DigAlarmcurrentThe digital input 17 has been activated.
1.3.6.1.4.1.539.20.5.3.34IdentityaiSPYInput18DigAlarmcurrentThe digital input 18 has been activated.
1.3.6.1.4.1.539.20.5.3.35IdentityaiSPYInput19DigAlarmcurrentThe digital input 19 has been activated.
1.3.6.1.4.1.539.20.5.3.36IdentityaiSPYInput20DigAlarmcurrentThe digital input 20 has been activated.
1.3.6.1.4.1.539.20.5.3.37IdentityaiSPYInput21DigAlarmcurrentThe digital input 21 has been activated.
1.3.6.1.4.1.539.20.5.3.38IdentityaiSPYInput22DigAlarmcurrentThe digital input 22 has been activated.
1.3.6.1.4.1.539.20.5.3.39IdentityaiSPYInput23DigAlarmcurrentThe digital input 23 has been activated.
1.3.6.1.4.1.539.20.5.3.40IdentityaiSPYInput24DigAlarmcurrentThe digital input 24 has been activated.
1.3.6.1.4.1.539.20.5.3.41IdentityaiSPYInput25DigAlarmcurrentThe digital input 25 has been activated.
1.3.6.1.4.1.539.20.5.3.42IdentityaiSPYInput26DigAlarmcurrentThe digital input 26 has been activated.
1.3.6.1.4.1.539.20.5.3.43IdentityaiSPYInput27DigAlarmcurrentThe digital input 27 has been activated.
1.3.6.1.4.1.539.20.5.3.44IdentityaiSPYInput28DigAlarmcurrentThe digital input 28 has been activated.
1.3.6.1.4.1.539.20.5.3.96IdentityaiSPYOnBatteryAlarmcurrentThe On Battery input has been activated.
1.3.6.1.4.1.539.20.5.3.97IdentityaiSPYLowBatteryAlarmcurrentThe aiSPY has detected a low battery condition.
1.3.6.1.4.1.539.20.6NodeaiSPYTraps
1.3.6.1.4.1.539.20.7NodeaiSPYAlarmHistory
1.3.6.1.4.1.539.20.7.1ScalaraiSPYAlarmHistoryEntriesread-onlycurrentThe present number of entries in the alarm history.
1.3.6.1.4.1.539.20.7.2ScalaraiSPYAlarmHistoryClearread-writemandatorySetting this value to ClearBuffer(1) will clear the alarm history buffer.
1.3.6.1.4.1.539.20.7.3TableaiSPYAlarmHistoryTablenot-accessiblecurrentA list of alarm history table entries stored in the in the non-volatile memory. The table contains zero, one, or many rows at any moment, depending upon the nu…
1.3.6.1.4.1.539.20.7.3.1RowaiSPYAlarmHistoryEntrynot-accessiblecurrentAn entry containing information applicable to a particular alarm history entry.
1.3.6.1.4.1.539.20.7.3.1.1ColumnaiSPYAlarmHistoryIdnot-accessiblecurrentA unique identifier for an alarm event. This value must remain constant.
1.3.6.1.4.1.539.20.7.3.1.2ColumnaiSPYAlarmHistoryTextread-onlycurrentA text desciption of the alarm history entry. Each of the strings will have the following format, AHxxx-id-type-timestamp label xxx = number entry in the table…
1.3.6.1.4.1.539.20.8NodeaiSPYTrapSettings
1.3.6.1.4.1.539.20.8.1ScalaraiSPYPersistantTrapsread-writemandatoryThe number of minutes between persistant traps. Set this to 0 to turn off persistant traps. This value is stored in non-volatile memory.
1.3.6.1.4.1.539.20.8.2ScalaraiSPYAlarmAcknowledgeread-writemandatorySetting this value to AcknowledgeAlarms(1) will stop the aiSPY from sending persistant traps and dial out sequences.
2NodeaiSPYAlarmEntryRemovedAn AlarmEntryAdded Trap signifies that the a sensor reading has gone below the high limit value or above the low limit value.
3NodeaiSPYAccessGrantedAn aiSPYAccessGranted Trap signifies that a valid key code sequence was processed by the aiSPY.
4NodeaiSPYAccessDeniedAn aiSPYAccessedDenied Trap signifies that an invalid key code sequence was processed by the aiSPY.