ALPINE-GEN-CARD-EDFA-MIB
35 objects
No module-level DESCRIPTION found.
Imported Objects
| ALPINE-ROOT | alpineGeneric |
| SNMPv2-SMI | Integer32 NOTIFICATION-TYPE OBJECT-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.52326.1.1 | NodealpineGenCardEdfa | |||
| 1.3.6.1.4.1.52326.1.1.1 | TablealpineGenCardEdfaInfosTable | not-accessible | current | Description. |
| 1.3.6.1.4.1.52326.1.1.1.1 | RowalpineGenCardEdfaInfosEntry | not-accessible | current | Description. |
| 1.3.6.1.4.1.52326.1.1.1.1.1 | ColumngceSlotNum | read-only | current | Slot number. |
| 1.3.6.1.4.1.52326.1.1.1.1.2 | ColumngceEdfaNum | read-only | current | EDFA Number in the line card. Up to 2 EDFA modules are supported in one line card. |
| 1.3.6.1.4.1.52326.1.1.1.1.3 | ColumngceMode | read-write | current | Work mode of EDFA. 1. AGC 2. APC Please note, when you want to change work mode, make sure the relative target value be set first. For example, if you want to … |
| 1.3.6.1.4.1.52326.1.1.1.1.4 | ColumngceOutputPowerTarget | read-write | current | Output power target of EDFA. If current work mode is APC, then output power will be applied immediately. If current work mode is AGC, then output power will be… |
| 1.3.6.1.4.1.52326.1.1.1.1.5 | ColumngceGainTarget | read-write | current | Gain target of EDFA. If current work mode is AGC, then output power will be applied immediately. If current work mode is APC, then output power will be applied… |
| 1.3.6.1.4.1.52326.1.1.1.1.6 | ColumngceOutputPower | read-only | current | Current output power of EDFA. |
| 1.3.6.1.4.1.52326.1.1.1.1.7 | ColumngceGain | read-only | current | Current gain of EDFA. |
| 1.3.6.1.4.1.52326.1.1.1.1.8 | ColumngceTemperature | read-only | current | Current temperature of EDFA. |
| 1.3.6.1.4.1.52326.1.1.1.1.9 | ColumngceSaveConfig | read-write | current | Save current configuration into flash for non-valatile setting. 0: Idle/Save Done. 1: Issue save command. 2: Saving. Only value 1 can be accepted in snmp set. |
| 1.3.6.1.4.1.52326.1.1.1.1.10 | ColumngceInputPower | read-only | current | Current input power of EDFA. |
| 1.3.6.1.4.1.52326.1.1.2 | NodealpineGenCardEdfaAlarm | |||
| 1.3.6.1.4.1.52326.1.1.2.1 | TablealpineGenCardEdfaAlarmThldTable | not-accessible | current | Description. |
| 1.3.6.1.4.1.52326.1.1.2.1.1 | RowalpineGenCardEdfaAlarmThldEntry | not-accessible | current | Description. |
| 1.3.6.1.4.1.52326.1.1.2.1.1.1 | ColumngceaSlotNum | read-only | current | Slot number. |
| 1.3.6.1.4.1.52326.1.1.2.1.1.2 | ColumngceaEdfaNum | read-only | current | EDFA Number in the line card. Up to 2 EDFA modules are supported in one line card. |
| 1.3.6.1.4.1.52326.1.1.2.1.1.3 | ColumngceaInputPowerThld | read-write | current | Low threshold of input power. |
| 1.3.6.1.4.1.52326.1.1.2.1.1.4 | ColumngceaOutputPowerThld | read-write | current | Low threshold of output power. |
| 1.3.6.1.4.1.52326.1.1.2.1.1.5 | ColumngceaTemperatureThld | read-write | current | High threshold of temperature. |
| 1.3.6.1.4.1.52326.1.1.2.2 | TablealpineGenEdfaAlarmInfoTable | not-accessible | current | Description. |
| 1.3.6.1.4.1.52326.1.1.2.2.1 | RowalpineGenEdfaAlarmInfoEntry | not-accessible | current | Description. |
| 1.3.6.1.4.1.52326.1.1.2.2.1.1 | ColumngeaiSlotNum | read-only | current | Description. |
| 1.3.6.1.4.1.52326.1.1.2.2.1.2 | ColumngeaiEdfaNum | read-only | current | EDFA Number in the line card. Up to 2 EDFA modules are supported in one line card. |
| 1.3.6.1.4.1.52326.1.1.2.2.1.3 | ColumngeaiCommonAlarm | read-only | current | If any alarm occurs, this field will set to 1. 0. Normal 1. One or some alarm occur. |
| 1.3.6.1.4.1.52326.1.1.2.2.1.4 | ColumngeaiCaseTemperatureAlarm | read-only | current | 0. Clear 1. Case temperature alarm occurs. |
| 1.3.6.1.4.1.52326.1.1.2.2.1.5 | ColumngeaiPumpTemperatureAlarm | read-only | current | 0. Clear 1. Pump temperature alarm occurs. |
| 1.3.6.1.4.1.52326.1.1.2.2.1.6 | ColumngeaiPumpBiasAlarm | read-only | current | 0. Clear 1. Pump bias alarm occurs. |
| 1.3.6.1.4.1.52326.1.1.2.2.1.7 | ColumngeaiLossInputAlarm | read-only | current | 0. Clear 1. Loss of input alarm occurs. |
| 1.3.6.1.4.1.52326.1.1.2.2.1.8 | ColumngeaiLossOutputAlarm | read-only | current | 0. Clear 1. Loss of output alarm occurs. |
| 1.3.6.1.4.1.52326.1.1.2.3 | NotificationalpineGenEdfaPowerAlarm | current | Description. | |
| 1.3.6.1.4.1.52326.1.1.2.4 | NotificationalpineGenEdfaTemperatureAlarm | current | Description. | |
| 1.3.6.1.4.1.52326.1.1.2.5 | NotificationalpineGenEdfaBiasAlarm | current | Description. | |
| 1.3.6.1.4.1.52326.1.1.2.6 | NotificationalpineGenEdfaLossAlarm | current | Description. |