APPIAN-PPORT-SONET-TRAP-MIB
183 objects
The MIB module to describe SONET/SDH Traps.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.2785.2.3.6.1.1.0 | NodeacSonetPortTraps | |||
| 1.3.6.1.4.1.2785.2.3.6.1.1.0.1 | NotificationacSonetPortFacilityLoopbackActiveTrap | current | The SONET physical interface has entered a loopback mode where the received optical data is sent out the optical transmitter. | |
| 1.3.6.1.4.1.2785.2.3.6.1.1.0.2 | NotificationacSonetPortFacilityLoopbackClearTrap | current | The SONET physical interface has disabled a loopback mode and is now transmitting and receiving optical data normally. | |
| 1.3.6.1.4.1.2785.2.3.6.1.1.0.3 | NotificationacSonetPortSectionDCCFailureAlarmTrap | current | Section DCC for this SONET port has failed. | |
| 1.3.6.1.4.1.2785.2.3.6.1.1.0.4 | NotificationacSonetPortSectionDCCFailureClearTrap | current | Section DCC for this SONET port has recovered. | |
| 1.3.6.1.4.1.2785.2.3.6.1.1.0.5 | NotificationacSonetPortLineDCCFailureAlarmTrap | current | Line DCC for this SONET port has failed. | |
| 1.3.6.1.4.1.2785.2.3.6.1.1.0.6 | NotificationacSonetPortLineDCCFailureClearTrap | current | Line DCC for this SONET port has recovered. | |
| 1.3.6.1.4.1.2785.2.3.6.1.1.0.7 | NotificationacSonetPortAppianDCCFailureAlarmTrap | current | Appian DCC for this SONET port has failed. | |
| 1.3.6.1.4.1.2785.2.3.6.1.1.0.8 | NotificationacSonetPortAppianDCCFailureClearTrap | current | Appian DCC for this SONET port has recovered. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0 | NodeacSonetSectionTraps | |||
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.1 | NotificationacSonetSectionLOSAlarmTrap | current | Loss of signal failure. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.2 | NotificationacSonetSectionLOSClearTrap | current | Loss of signal recovered. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.3 | NotificationacSonetSectionLOFAlarmTrap | current | Loss of frame failure at section level. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.4 | NotificationacSonetSectionLOFClearTrap | current | Loss of frame at section level recovered. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.5 | NotificationacSonetSectionTraceAlarmTrap | current | The section trace identifier received for the SONET interface was unexpected. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.6 | NotificationacSonetSectionTraceClearTrap | current | The section trace identifier mismatch condition for the SONET interface has recovered. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.7 | NotificationacSonetSection15MinuteESAlarmTrap | current | Errored seconds for the section have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.8 | NotificationacSonetSection15MinuteESClearTrap | current | Errored seconds for the section have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.9 | NotificationacSonetSection15MinuteSESAlarmTrap | current | Severly errored seconds for the section have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.10 | NotificationacSonetSection15MinuteSESClearTrap | current | Severely errored seconds for the section have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.11 | NotificationacSonetSection15MinuteSEFAlarmTrap | current | Severely errored frames for the section have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.12 | NotificationacSonetSection15MinuteSEFClearTrap | current | Severely errored frames for the section have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.13 | NotificationacSonetSection15MinuteCVAlarmTrap | current | Coding violations, or BIP errors, for the section have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.14 | NotificationacSonetSection15MinuteCVClearTrap | current | Coding violations, or BIP errors, for the section have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.15 | NotificationacSonetSectionDayESAlarmTrap | current | Errored seconds for the section have exceeded the threshold for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.16 | NotificationacSonetSectionDayESClearTrap | current | Errored seconds for the section have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.17 | NotificationacSonetSectionDaySESAlarmTrap | current | Severely errored seconds for the section have exceeded the threshold for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.18 | NotificationacSonetSectionDaySESClearTrap | current | Severely errored seconds for the section have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.19 | NotificationacSonetSectionDaySEFAlarmTrap | current | Severely errored frames for the section have exceeded the threshold for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.20 | NotificationacSonetSectionDaySEFClearTrap | current | Severely errored frames for the section have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.21 | NotificationacSonetSectionDayCVAlarmTrap | current | Coding violations, or BIP errors, for the section have exceeded the threshold for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.2.0.22 | NotificationacSonetSectionDayCVClearTrap | current | Coding violations, or BIP errors, for the section have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0 | NodeacSonetLineTraps | |||
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.1 | NotificationacSonetLineAISAlarmTrap | current | AIS detected at line level. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.2 | NotificationacSonetLineAISClearTrap | current | AIS cleared at line level. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.3 | NotificationacSonetLineRDIAlarmTrap | current | RDI detected at line level. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.4 | NotificationacSonetLineRDIClearTrap | current | RDI cleared at line level. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.5 | NotificationacSonetLine15MinuteESAlarmTrap | current | Errored seconds for the line have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.6 | NotificationacSonetLine15MinuteESClearTrap | current | Errored seconds for the line have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.7 | NotificationacSonetLine15MinuteSESAlarmTrap | current | Severely errored seconds for the line have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.8 | NotificationacSonetLine15MinuteSESClearTrap | current | Severely errored seconds for the line have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.9 | NotificationacSonetLine15MinuteCVAlarmTrap | current | BIP errors for the line have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.10 | NotificationacSonetLine15MinuteCVClearTrap | current | BIP errors for the line have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.11 | NotificationacSonetLine15MinuteUASAlarmTrap | current | Unavailable seconds for the line have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.12 | NotificationacSonetLine15MinuteUASClearTrap | current | Unavailable seconds for the line have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.13 | NotificationacSonetLineDayESAlarmTrap | current | Errored seconds for the line have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.14 | NotificationacSonetLineDayESClearTrap | current | Errored seconds for the line have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.15 | NotificationacSonetLineDaySESAlarmTrap | current | Severely errored seconds for the line have exceeded the threshold for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.16 | NotificationacSonetLineDaySESClearTrap | current | Severely errored seconds for the line have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.17 | NotificationacSonetLineDayCVAlarmTrap | current | BIP errors for the line have exceeded the threshold for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.18 | NotificationacSonetLineDayCVClearTrap | current | BIP errors for the line have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.19 | NotificationacSonetLineDayUASAlarmTrap | current | Unavailable seconds for the line have exceeded the threshold for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.20 | NotificationacSonetLineDayUASClearTrap | current | Unavailable seconds for the line have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.21 | NotificationacSonetLineProtectionSwitchAlarmTrap | current | Protection switch is currently active on this SONET interface. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.22 | NotificationacSonetLineProtectionSwitchClearTrap | current | Protection switch has been released on this SONET interface. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.23 | NotificationacSonetLineProtectionFailureAlarmTrap | current | Protection switch failure has occured for this SONET interface. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.24 | NotificationacSonetLineProtectionFailureClearTrap | current | Protection switch failure has cleared for this SONET interface. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.25 | NotificationacSonetLineProtectionChannelMismatchAlarmTrap | current | A protection switching channel mismatch failure has occured on the SONET interface. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.26 | NotificationacSonetLineProtectionChannelMismatchClearTrap | current | A protection switching channel mismatch failure has cleared on the SONET interface. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.27 | NotificationacSonetLineProtectionModeMismatchAlarmTrap | current | A protection switching mode mismatch failure has occured on the SONET interface. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.28 | NotificationacSonetLineProtectionModeMismatchClearTrap | current | A protection switching mode mismatch failure has cleared on the SONET interface. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.29 | NotificationacSonetLineProtectionSwitchingByteFailureAlarmTrap | current | A protection switching byte failure has been detected on the SONET interface. | |
| 1.3.6.1.4.1.2785.2.3.6.1.3.0.30 | NotificationacSonetLineProtectionSwitchingByteFailureClearTrap | current | A protection switching byte failure has been cleared on the SONET interface. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0 | NodeacSonetFarEndLineTraps | |||
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.1 | NotificationacSonetFarEndLine15MinuteESAlarmTrap | current | Errored seconds for the far end line have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.2 | NotificationacSonetFarEndLine15MinuteESClearTrap | current | Errored seconds for the far end line have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.3 | NotificationacSonetFarEndLine15MinuteSESAlarmTrap | current | Severely errored seconds for the far end line have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.4 | NotificationacSonetFarEndLine15MinuteSESClearTrap | current | Severely errored seconds for the far end line have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.5 | NotificationacSonetFarEndLine15MinuteCVAlarmTrap | current | Coding violations for the far end line have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.6 | NotificationacSonetFarEndLine15MinuteCVClearTrap | current | Coding violations for the far end line have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.7 | NotificationacSonetFarEndLine15MinuteUASAlarmTrap | current | Unavailable seconds for the far end line have exceeded the threshold for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.8 | NotificationacSonetFarEndLine15MinuteUASClearTrap | current | Unavailable seconds for the far end line have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.9 | NotificationacSonetFarEndLineDayESAlarmTrap | current | Errored seconds for the far end line have exceeded the threshold for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.10 | NotificationacSonetFarEndLineDayESClearTrap | current | Errored seconds for the far end line have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.11 | NotificationacSonetFarEndLineDaySESAlarmTrap | current | Severely errored seconds for the far end line have exceeded the threshold for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.12 | NotificationacSonetFarEndLineDaySESClearTrap | current | Severely errored seconds for the far end line have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.13 | NotificationacSonetFarEndLineDayCVAlarmTrap | current | Coding violations for the far end line have exceeded the threshold for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.14 | NotificationacSonetFarEndLineDayCVClearTrap | current | Coding violations for the far end line have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.15 | NotificationacSonetFarEndLineDayUASAlarmTrap | current | Unavailable seconds for the far end line have exceeded the threshold for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.1.4.0.16 | NotificationacSonetFarEndLineDayUASClearTrap | current | Unavailable seconds for the far end line have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0 | NodeacSonetPathTraps | |||
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.1 | NotificationacSonetPathLOPAlarmTrap | current | The SONET Path reports a Loss of Pointer (LOP) failure. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.2 | NotificationacSonetPathLOPClearTrap | current | The SONET Path recovers from a Loss of Pointer (LOP) failure. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.3 | NotificationacSonetPathAISAlarmTrap | current | The SONET Path reports an Alarm Indication Signal (AIS). | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.4 | NotificationacSonetPathAISClearTrap | current | The SONET Path recovers from an Alarm Indication Signal (AIS). | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.5 | NotificationacSonetPathRDIAlarmTrap | current | The SONET Path reports an RDI signal. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.6 | NotificationacSonetPathRDIClearTrap | current | The SONET Path recovers from an RDI signal. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.7 | NotificationacSonetPathUnequipedAlarmTrap | current | The SONET Path reports an unequipped condition exists. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.8 | NotificationacSonetPathUnequipedClearTrap | current | The SONET Path reports an unequipped condition has been cleared. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.9 | NotificationacSonetPathTraceAlarmTrap | current | The path trace identifier received for the SONET interface was unexpected. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.10 | NotificationacSonetPathTraceClearTrap | current | The path trace identifier mismatch condition for the SONET interface has recovered. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.11 | NotificationacSonetPathPLMAlarmTrap | current | A payload label mismatch has been detected on this SONET interface. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.12 | NotificationacSonetPathPLMClearTrap | current | A payload label mismatch has been cleared on this SONET interface. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.13 | NotificationacSonetPathSDAlarmTrap | current | The Signal Defects bit error rate for SONET Path have exceeded the configured threshold. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.14 | NotificationacSonetPathSDClearTrap | current | The Signal Defects bit error rate for SONET Path have cleared. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.15 | NotificationacSonetPathSFAlarmTrap | current | The Signal Failure bit error rate for SONET Path has exceeded the configured threshold. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.16 | NotificationacSonetPathSFClearTrap | current | The Signal Failure bit error rate for SONET Path has cleared. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.17 | NotificationacSonetPath15MinuteESAlarmTrap | current | The errored seconds (ES) for SONET Path exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.18 | NotificationacSonetPath15MinuteESClearTrap | current | The errored seconds (ES) for SONET Path have cleared for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.19 | NotificationacSonetPath15MinuteSESAlarmTrap | current | The severely errored seconds (SES) for SONET Path exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.20 | NotificationacSonetPath15MinuteSESClearTrap | current | The severely errored seconds (SES) for SONET Path have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.21 | NotificationacSonetPath15MinuteCVAlarmTrap | current | The BIP errors for SONET Path exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.22 | NotificationacSonetPath15MinuteCVClearTrap | current | The BIP errors for SONET Path have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.23 | NotificationacSonetPath15MinuteUASAlarmTrap | current | The Unavailable Seconds for SONET Path exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.24 | NotificationacSonetPath15MinuteUASClearTrap | current | The Unavailable Seconds for SONET Path have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.25 | NotificationacSonetPathDayESAlarmTrap | current | The errored seconds (ES) for SONET Path exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.26 | NotificationacSonetPathDayESClearTrap | current | The errored seconds (ES) for SONET Path have cleared for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.27 | NotificationacSonetPathDaySESAlarmTrap | current | The severely errored seconds (SES) for SONET Path exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.28 | NotificationacSonetPathDaySESClearTrap | current | The severely errored seconds (SES) for SONET Path have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.29 | NotificationacSonetPathDayCVAlarmTrap | current | The BIP errors for SONET Path exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.30 | NotificationacSonetPathDayCVClearTrap | current | The BIP errors for SONET Path have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.31 | NotificationacSonetPathDayUASAlarmTrap | current | The Unavailable Seconds for SONET Path exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.32 | NotificationacSonetPathDayUASClearTrap | current | The Unavailable Seconds for SONET Path have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.33 | NotificationacSonetPathRingProtAlarmTrap | current | The SONET Path reports a ring protection switch. | |
| 1.3.6.1.4.1.2785.2.3.6.2.1.0.34 | NotificationacSonetPathRingProtClearTrap | current | The SONET Path recovers from a ring protection switch. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0 | NodeacSonetFarEndPathTraps | |||
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.1 | NotificationacSonetFarEndPath15MinuteESAlarmTrap | current | The errored seconds (ES) for the SONET Far End Path exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.2 | NotificationacSonetFarEndPath15MinuteESClearTrap | current | The Errored Seconds for SONET Path have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.3 | NotificationacSonetFarEndPath15MinuteSESAlarmTrap | current | The Severely errored seconds (SES) for the SONET Far End Path exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.4 | NotificationacSonetFarEndPath15MinuteSESClearTrap | current | The Severely Errored Seconds for SONET Path have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.5 | NotificationacSonetFarEndPath15MinuteCVAlarmTrap | current | BIP errors for SONET Far End Path exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.6 | NotificationacSonetFarEndPath15MinuteCVClearTrap | current | The BIP errors for SONET Path have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.7 | NotificationacSonetFarEndPath15MinuteUASAlarmTrap | current | Unavailable seconds (UAS) for SONET Far ENd Path exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.8 | NotificationacSonetFarEndPath15MinuteUASClearTrap | current | The Unavailable Seconds for SONET Path have recovered for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.9 | NotificationacSonetFarEndPathDayESAlarmTrap | current | The errored seconds (ES) for the SONET Far End Path exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.10 | NotificationacSonetFarEndPathDayESClearTrap | current | The Errored Seconds for SONET Path have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.11 | NotificationacSonetFarEndPathDaySESAlarmTrap | current | The Severely errored seconds (SES) for the SONET Far End Path exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.12 | NotificationacSonetFarEndPathDaySESClearTrap | current | The Severely Errored Seconds for SONET Path have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.13 | NotificationacSonetFarEndPathDayCVAlarmTrap | current | BIP errors for SONET Far End Path exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.14 | NotificationacSonetFarEndPathDayCVClearTrap | current | The BIP errors for SONET Path have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.15 | NotificationacSonetFarEndPathDayUASAlarmTrap | current | Unavailable seconds (UAS) for SONET Far ENd Path exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.2.2.0.16 | NotificationacSonetFarEndPathDayUASClearTrap | current | The Unavailable Seconds for SONET Path have recovered for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0 | NodeacSonetVTTrap | |||
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.1 | NotificationacSonetVTLOPAlarmTrap | current | A Loss of Pointer (LOP) for a SONET VT has been detected. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.2 | NotificationacSonetVTLOPClearTrap | current | The SONET VT has recovered from a Loss of Pointer (LOP). | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.3 | NotificationacSonetVTPathAISAlarmTrap | current | A path alarm indication signal (AIS) for a SONET VT has been detected. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.4 | NotificationacSonetVTPathAISClearTrap | current | A VT path has recovered from an alarm indication signal (AIS). | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.5 | NotificationacSonetVTPathRFIAlarmTrap | current | A path remote fault indication (RFI) for a SONET VT has been detected. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.6 | NotificationacSonetVTPathRFIClearTrap | current | A path remote fault indication (RFI) for a SONET VT has been cleared. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.7 | NotificationacSonetVTUnequippedAlarmTrap | current | The SONET VT has detected an unequipped condition. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.8 | NotificationacSonetVTUnequippedClearTrap | current | The SONET VT has cleared an unequipped condition. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.9 | NotificationacSonetVTPLMAlarmTrap | current | A payload label mismatch (PLM) error has been detected for a SONET VT. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.10 | NotificationacSonetVTPLMClearTrap | current | A payload label mismatch (PLM) error has been cleared for a SONET VT. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.11 | NotificationacSonetVTSDAlarmTrap | current | The signal degradation threshold for a VT running over this SONET interface exceeded the configured threshold value. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.12 | NotificationacSonetVTSDClearTrap | current | The signal degradation bit error rate for this VT path has cleared. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.13 | NotificationacSonetVTSFAlarmTrap | current | The signal fail threshold for a VT running over this SONET interface exceeded the configured threshold value. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.14 | NotificationacSonetVTSFClearTrap | current | The signal fail bit error rate for this VT path has cleared. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.15 | NotificationacSonetVT15MinuteESAlarmTrap | current | The errored seconds (ES) threshold for a SONET VT been exceeded during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.16 | NotificationacSonetVT15MinuteESClearTrap | current | The errored seconds (ES) threshold for a SONET VT has been cleared for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.17 | NotificationacSonetVT15MinuteSESAlarmTrap | current | The severly errored seconds (SES) for a SONET VT exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.18 | NotificationacSonetVT15MinuteSESClearTrap | current | The severly errored seconds (SES) for a SONET VT has been cleared for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.19 | NotificationacSonetVT15MinuteCVAlarmTrap | current | The coding violations (CV) for a SONET VT exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.20 | NotificationacSonetVT15MinuteCVClearTrap | current | The coding violations (CV) for a SONET VT have cleared for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.21 | NotificationacSonetVT15MinuteUASAlarmTrap | current | The unavailable seconds (UAS) for a SONET VT exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.22 | NotificationacSonetVT15MinuteUASClearTrap | current | The unavailable seconds (UAS) for a SONET VT have cleared for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.23 | NotificationacSonetVTDayESAlarmTrap | current | The errored seconds (ES) threshold for a SONET VT been exceeded during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.24 | NotificationacSonetVTDayESClearTrap | current | The errored seconds (ES) threshold for a SONET VT has been cleared for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.25 | NotificationacSonetVTDaySESAlarmTrap | current | The severly errored seconds (SES) for a SONET VT exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.26 | NotificationacSonetVTDaySESClearTrap | current | The severly errored seconds (SES) for a SONET VT has been cleared for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.27 | NotificationacSonetVTDayCVAlarmTrap | current | The coding violations (CV) for a SONET VT exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.28 | NotificationacSonetVTDayCVClearTrap | current | The coding violations (CV) for a SONET VT have cleared for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.29 | NotificationacSonetVTDayUASAlarmTrap | current | The unavailable seconds (UAS) for a SONET VT exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.30 | NotificationacSonetVTDayUASClearTrap | current | The unavailable seconds (UAS) for a SONET VT have cleared for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.31 | NotificationacSonetVTRingProtSwitchAlarmTrap | current | A Sonet VT ring protection switch has been detected. | |
| 1.3.6.1.4.1.2785.2.3.6.3.1.0.32 | NotificationacSonetVTRingProtSwitchClearTrap | current | The SONET VT has recovered from Sonet ring protection switch. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0 | NodeacSonetFarEndVTTraps | |||
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.1 | NotificationacSonetFarEndVT15MinuteESAlarmTrap | current | Errored seconds (ES) for the Far End SONET VT exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.2 | NotificationacSonetFarEndVT15MinuteESClearTrap | current | Errored seconds (ES) for the Far End SONET VT have cleared for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.3 | NotificationacSonetFarEndVT15MinuteSESAlarmTrap | current | Severly errored seconds (SES) for the Far End SONET VT exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.4 | NotificationacSonetFarEndVT15MinuteSESClearTrap | current | Severly errored seconds (SES) for the Far End SONET VT have cleared for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.5 | NotificationacSonetFarEndVT15MinuteCVAlarmTrap | current | Coding violations (CV) for a SONET VT exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.6 | NotificationacSonetFarEndVT15MinuteCVClearTrap | current | Coding violations (CV) for a SONET VT have cleared for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.7 | NotificationacSonetFarEndVT15MinuteUASAlarmTrap | current | Unavailable seconds (UAS) for a SONET VT exceeded the configured threshold during the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.8 | NotificationacSonetFarEndVT15MinuteUASClearTrap | current | Unavailable seconds (UAS) for a SONET VT have cleared for the current 15 minute interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.9 | NotificationacSonetFarEndVTDayESAlarmTrap | current | Errored seconds (ES) for the Far End SONET VT exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.10 | NotificationacSonetFarEndVTDayESClearTrap | current | Errored seconds (ES) for the Far End SONET VT have cleared for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.11 | NotificationacSonetFarEndVTDaySESAlarmTrap | current | Severly errored seconds (SES) for the Far End SONET VT exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.12 | NotificationacSonetFarEndVTDaySESClearTrap | current | Severly errored seconds (SES) for the Far End SONET VT have cleared for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.13 | NotificationacSonetFarEndVTDayCVAlarmTrap | current | Coding violations (CV) for a SONET VT exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.14 | NotificationacSonetFarEndVTDayCVClearTrap | current | Coding violations (CV) for a SONET VT have cleared for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.15 | NotificationacSonetFarEndVTDayUASAlarmTrap | current | Unavailable seconds (UAS) for a SONET VT exceeded the configured threshold during the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.3.2.0.16 | NotificationacSonetFarEndVTDayUASClearTrap | current | Unavailable seconds (UAS) for a SONET VT have cleared for the current day interval. | |
| 1.3.6.1.4.1.2785.2.3.6.4 | IdentityacSonetTraps | The MIB module to describe SONET/SDH Traps. |