MIB Viewer

APTIS-TRAPS-MIB

102 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2637.2.5.1NodeaptisProtraps
1.3.6.1.4.1.2637.2.5.1.1Nodeaptis-fandownThe fans on the chassis have stopped functioning. This trap is only supported on systems with the smart fan tray. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.2Nodeaptis-dc1downThe DC1 power supply has stopped functioning. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.3Nodeaptis-dc2downThe DC2 power supply has stopped functioning. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.4Nodeaptis-ac1downThe AC1 power supply has stopped functioning. This trap carries a severity of 6 (emergency). NOTE: This trap is no longer supported.
1.3.6.1.4.1.2637.2.5.1.5Nodeaptis-ac2downThe AC2 power supply has stopped functioning. This trap carries a severity of 6 (emergency). NOTE: This trap is no longer supported.
1.3.6.1.4.1.2637.2.5.1.6Nodeaptis-acdc1downThe ACDC1 power converter has stopped functioning. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.7Nodeaptis-acdc2downThe ACDC2 power converter has stopped functioning. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.8Nodeaptis-acdc3downThe ACDC3 power converter has stopped functioning. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.9Nodeaptis-flashmountThe flash card has been mounted. See also trap aptis-flashdismount. This trap carries a severity of 2 (warning).
1.3.6.1.4.1.2637.2.5.1.10Nodeaptis-flashdismountThe flash card has been dismounted. See also trap aptis-flashmount. This trap carries a severity of 2 (warning).
1.3.6.1.4.1.2637.2.5.1.11Nodeaptis-coldStartA coldStart trap signifies that the sending protocol entity is reinitializing itself such that the agent's configuration or the protocol entity implementation …
1.3.6.1.4.1.2637.2.5.1.12NodewarmStartA warmStart trap signifies that the sending protocol entity is reinitializing itself such that neither the agent configuration nor the protocol entity implemen…
1.3.6.1.4.1.2637.2.5.1.13NodelinkDownA linkDown trap signifies that the sending protocol entity recognizes a failure in one of the communications links represented in the agent's configuration. Th…
1.3.6.1.4.1.2637.2.5.1.14NodelinkUpA linkUp trap signifies that the sending protocol entity recognizes that one of the communications links represented in the agent's configuration has come up. …
1.3.6.1.4.1.2637.2.5.1.15NodeauthenticationFailureAn authenticationFailure trap signifies that the sending protocol entity is the addressee of a protocol message that is not properly authenticated. While imple…
1.3.6.1.4.1.2637.2.5.1.16Nodeaptis-radius-failNo Radius Server is available. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.17Nodeaptis-slot-upSlot is up. See also trap aptis-slot-down. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.18Nodeaptis-slot-downSlot is down. See also trap aptis-slot-up. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.19Nodeaptis-slot-cfg-chngSlot configuration has changed. This trap carries a severity of 1 (notice).
1.3.6.1.4.1.2637.2.5.1.20Nodeaptis-ds1-red-alarmThe specified DS1 is in red alarm. See also trap aptis-ds1-alarm-clear. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.21Nodeaptis-ds1-yellow-alarmThe specified DS1 is in yellow alarm. See also trap aptis-ds1-alarm-clear. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.22Nodeaptis-ds1-alarm-clearThe specified DS1 is no longer in alarm. See also traps aptis-ds1-red-alarm and aptis-ds1-yellow-alarm. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.23Nodeaptis-ds3-red-alarmThe specified DS3 is in red alarm. See also trap aptis-ds3-alarm-clear. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.24Nodeaptis-ds3-yellow-alarmThe specified DS3 is in yellow alarm. See also trap aptis-ds3-alarm-clear. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.25Nodeaptis-ds3-alarm-clearThe specified DS3 is no longer in alarm. See also traps aptis-ds3-red-alarm and aptis-ds3-yellow-alarm. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.26Nodeaptis-isdn-link-upThe specified ISDN data link is up. See also trap aptis-isdn-link-down. This trap carries a severity of 3 (error).
1.3.6.1.4.1.2637.2.5.1.27Nodeaptis-isdn-link-downThe specified ISDN data link is down. See also trap aptis-isdn-link-up. This trap carries a severity of 3 (error).
1.3.6.1.4.1.2637.2.5.1.28Nodeaptis-isdn-link-resetThe specified ISDN data link has been reset by the switch. This trap carries a severity of 3 (error).
1.3.6.1.4.1.2637.2.5.1.29Nodeaptis-temp-exceededThe card in the specified slot has exceeded its safe operational temperature and is being shut down. See also traps cvxSlotTempWarning and cvxSlotTempNormal. T…
1.3.6.1.4.1.2637.2.5.1.30Nodeaptis-cvx-ss7-gateway-failoverThe CVX has failed over to the next CVX-SS7 Gateway. This trap carries a severity of 2 (warning).
1.3.6.1.4.1.2637.2.5.1.31Nodeaptis-l2f-tunnel-startThe CVX has successfully opened an L2F tunnel. See also trap aptis-l2f-tunnel-stop. This trap carries a severity of 1 (notice). This trap has been superceded b…
1.3.6.1.4.1.2637.2.5.1.32Nodeaptis-l2f-tunnel-stopThe CVX has closed an L2F tunnel that had been opened successfully. See also trap aptis-l2f-tunnel-start. This trap carries a severity of 1 (notice). This trap…
1.3.6.1.4.1.2637.2.5.1.33Nodeaptis-l2f-tunnel-rejectThe CVX has failed to open an L2F tunnel. This trap carries a severity of 5 (alert). This trap has been superceded by cvx-tunnel-reject (55).
1.3.6.1.4.1.2637.2.5.1.34Nodecvx-MAC-modems-below-thresholdThe percent of functioning modems on the specified MAC board has gone below the defined threshold. See also trap cvx-MAC-modems-above-threshold. This trap carr…
1.3.6.1.4.1.2637.2.5.1.35Nodecvx-MAC-modems-above-thresholdThe percent of functioning modems on the specified MAC board has gone above or equal to the defined threshold. See also trap cvx-MAC-modems-below-threshold. Th…
1.3.6.1.4.1.2637.2.5.1.36Nodecvx-total-modems-below-thresholdThe percent of functioning modems on the CVX has fallen below the defined threshold. See also trap cvx-total-modems-above-threshold. This trap carries a severi…
1.3.6.1.4.1.2637.2.5.1.37Nodecvx-total-modems-above-thresholdThe percent of functioning modems on the CVX is now equal to or above the defined threshold. See also trap cvx-total-modems-below-threshold. This trap carries …
1.3.6.1.4.1.2637.2.5.1.38Nodecvx-local-pswd-changeThe local password on the CVX has been modified. This trap carries a severity of 1 (notice).
1.3.6.1.4.1.2637.2.5.1.39Nodecvx-auth-server-failoverThe most recently used authentication server cannot be contacted. The primary contact has been switched to the server indicated. See also trap cvxAuthServerRev…
1.3.6.1.4.1.2637.2.5.1.40Nodecvx-acct-server-failureCommunication has been lost with all configured accounting servers. The address indicated in the trap is the last address tried. This trap carries a severity o…
1.3.6.1.4.1.2637.2.5.1.41Nodecvx-acct-server-failoverThe most recently used accounting server cannot be contacted. The primary contact has been switched to the server indicated. This trap carries a severity of 2 …
1.3.6.1.4.1.2637.2.5.1.42Nodecvx-ss7-gateway-downCommunication has been lost with the ss7 gateway indicated. See also trap cvx-ss7-gateway-up. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.43Nodecvx-ss7-gateway-upCommunication has been established with the ss7 gateway indicated. See also trap cvx-ss7-gateway-down. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.44Nodecvx-Ds3-failoverThe primary DS3 in the indicated slot has failed and the secondary has resumed responsibility. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.45Nodecvx-Scc-failoverThe primary SCC in the indicated slot has failed and the secondary has resumed operation. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.46Nodecvx-ethernet-port-upThe specified Ethernet Port is initialized. Thes trap will occur at boot time and when an ethernet port is reinitialized after a cvx-ethernet-port-down trap. T…
1.3.6.1.4.1.2637.2.5.1.47Nodecvx-ethernet-port-downThe specified Ethernet port has failed. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.48Nodecvx-Hssi-port-upThe specified HSSI Port is initialized. This trap will occur at boot time and when an HSSI port is reinitialized after a cvx-hssi-port-down trap. This trap car…
1.3.6.1.4.1.2637.2.5.1.49Nodecvx-Hssi-port-downThe specified HSSI port has failed. This trap carries a severity of 7 (fatal).
1.3.6.1.4.1.2637.2.5.1.50Nodecvx-local-auth-failure-threshold-exceededA consecutive number of local authorization failures has exceeded the noted threshold. The trap contains the number of consecutive failed attempts and addition…
1.3.6.1.4.1.2637.2.5.1.51Nodecvx-preAuth-failNo pre-authorization server is available. The IP address shows the last server tried. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.52Nodecvx-auth-failNo authorization server is available. The IP address shows the last server tried. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.53Nodecvx-tunnel-startThe CVX has successfully opened a tunnel. This trap carries a severity of 1 (notice).
1.3.6.1.4.1.2637.2.5.1.54Nodecvx-tunnel-stopThe CVX has closed a tunnel that had been opened successfully. This trap carries a severity of 1 (notice).
1.3.6.1.4.1.2637.2.5.1.55Nodecvx-tunnel-rejectThe CVX has failed to open a tunnel. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.56Nodecvx-radius-packet-discardA radius response packet was discarded. This trap carries a severity of 2 (warning).
1.3.6.1.4.1.2637.2.5.1.57Nodecvx-fanupThe fans on the chassis have resumed functioning. This trap is only supported on systems with the smart fan tray. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.58Nodecvx-dc1upThe DC1 power supply has resumed functioning. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.59Nodecvx-dc2upThe DC2 power supply has resumed functioning. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.62Nodecvx-acdc1upThe ACDC1 power converter has resumed functioning. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.63Nodecvx-acdc2upThe ACDC2 power converter has resumed functioning. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.64Nodecvx-acdc3upThe ACDC3 power converter has resumed functioning. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.65Nodecvx-filter-errorA Filter-Id attribute containing an unknown filter name was received from a radius server. This trap carries a severity of 5 (alert).
1.3.6.1.4.1.2637.2.5.1.66Nodecvx-slave-flash-missingNo flash card has been detected on the slave SCC (System Control Card) unit. See also trap cvxSlaveSccFlashDetected. This trap carries a severity of 3 (error).
1.3.6.1.4.1.2637.2.5.1.67NodecvxSlaveSccFlashDetectedThe flash card has been detected on the slave SCC (System Control Card) unit. NOTE: This trap is only sent if the complementary trap cvx-slave-flash-missing wa…
1.3.6.1.4.1.2637.2.5.1.68NodecvxAuthServerRevivedThe authentication server identified by trapIpAddr that had previously failed has been revived. The server is identified by trapIpAddr. See also trap cvx-auth-…
1.3.6.1.4.1.2637.2.5.1.69NodecvxPrimaryDhcpServerContactFailedFailed to establish contact with the primary DHCP server identified by trapIpAddr. If a secondary DHCP server has been configured, it will be tried next. NOTE:…
1.3.6.1.4.1.2637.2.5.1.70NodecvxPrimaryDhcpServerContactRevivedContact has been reestablished with the primary DHCP server identified by trapIpAddr. NOTE: Every time a new request is received to obtain an IP address via DH…
1.3.6.1.4.1.2637.2.5.1.71NodecvxSecondaryDhcpServerContactFailedFailed to establish contact with the secondary (backup) DHCP server identified by trapIpAddr. Note that no trap is issued when contact is reestablished with th…
1.3.6.1.4.1.2637.2.5.1.73NodecvxSlotTempWarningSlot temperature has exceeded the configured warning level. If the slot temperature exceeds the configured threshold limit, the card in the slot will be shut d…
1.3.6.1.4.1.2637.2.5.1.74NodecvxSlotTempNormalSlot temperature is back to normal (below the configured warning level). trapSlotNum identifies the affected slot. trapTempCurrent specifies the current temper…
1.3.6.1.4.1.2637.2.5.1.75NodecvxSlaveSccRemovedThe master SCC (System Control Card) has detected that the slave SCC has been removed from the system. File synchronization will cease. See also traps cvxSlave…
1.3.6.1.4.1.2637.2.5.1.76NodecvxSlaveSccInsertedThe master SCC (System Control Card) has detected that the slave SCC has been inserted into the system. File synchronization will start or resume. See also tra…
1.3.6.1.4.1.2637.2.5.1.77NodecvxFailedSlaveSccRemovedThe master SCC (System Control Card) has detected that the slave SCC that had previously failed has been removed from the system. See also traps cvxSlaveSccRem…
1.3.6.1.4.1.2637.2.5.1.79NodecvxCardCrashedThe card in slot trapSlotNum has crashed. The crash block has been written to the flash card. A restart of the card will be attempted. This trap carries a seve…
1.3.6.1.4.1.2637.2.5.1.80NodecvxCardNotRespondingThe card in slot trapSlotNum is not responding to the system watchdog. A restart of the card will be attempted. This trap carries a severity of 6 (emergency).
1.3.6.1.4.1.2637.2.5.1.81NodecvxLocalAuthenticationFailureThis trap is generated when a user fails the local authentication process while trying to log into the CVX shell service. Local authentication is performed via…
1.3.6.1.4.1.2637.2.5.1.82NodecvxSessionAuthenticationFailureThis trap is generated when an authentication failure occurs during session setup. The session id number associated with the session is contained in the variab…
1.3.6.1.4.1.2637.2.5.1.83NodeencryptionNotAllowedEncryption operations cannot be performed if the SCC I board is present. Encryption is only supported on a SCC II board that has a VMS120 chip for encryption a…
1.3.6.1.4.1.2637.2.5.1.84NodecvxRadiusdSessionDiscA Disconnect-Request received from the RADIUS client with IP address trapIpAddr resulted in termination of one or more sessions. This trap carries a severity o…
1.3.6.1.4.1.2637.2.5.1.85NodecvxRadiusdUnknownClientA Disconnect-Request was received from an unknown RADIUS client with IP address trapIpAddr. This trap carries a severity of 0 (info).
1.3.6.1.4.1.2637.2.5.1.86NodecvxRadiusdClientAuthFailedA Disconnect-Request received from the RADIUS client with IP address trapIpAddr failed authentication. This trap carries a severity of 0 (info).
1.3.6.1.4.1.2637.2.5.1.87NodecvxSlaveSccFileSyncFailedThe master SCC (System Control Card) detected error(s) while performing file synchronization with the slave SCC. This trap carries a severity of 4 (critical).
1.3.6.1.4.1.2637.2.5.1.88NodecvxSlaveSccFileSyncCompletedThe master SCC (System Control Card) successfully completed file synchronization with the slave SCC. This trap carries a severity of 1 (notice).
1.3.6.1.4.1.2637.2.5.1.89NodecvxSlaveSccFailedThe master SCC (System Control Card) has detected that the slave SCC has failed. File synchronization will cease. See also related trap cvxFailedSlaveSccRemove…
1.3.6.1.4.1.2637.2.5.2ScalartrapGenNumread-onlymandatoryA unigue incrementing integer assigned for each trap.
1.3.6.1.4.1.2637.2.5.3ScalartrapPathread-onlymandatoryA path string to the object associated with the trap.
1.3.6.1.4.1.2637.2.5.4ScalartrapSeverityread-onlymandatoryThe severity of this trap, 7 being most severe.
1.3.6.1.4.1.2637.2.5.5ScalartrapStringread-onlymandatoryExtra text associated with the trap.
1.3.6.1.4.1.2637.2.5.6ScalartrapIpAddrread-onlymandatoryAn IP address associated with the trap.
1.3.6.1.4.1.2637.2.5.7ScalartrapSlotNumread-onlymandatoryA slot number associated with the trap.
1.3.6.1.4.1.2637.2.5.8ScalartrapPortNumread-onlymandatoryA port number associated with the trap.
1.3.6.1.4.1.2637.2.5.9ScalartrapTunnelTyperead-onlymandatoryA tunnel type associated with the trap.
1.3.6.1.4.1.2637.2.5.10ScalartrapUserNameread-onlymandatoryThe user name assiciated with this trap.
1.3.6.1.4.1.2637.2.5.11ScalartrapAuthThresholdread-onlymandatoryThe number of consecutive authorization failures.
1.3.6.1.4.1.2637.2.5.12ScalartrapFilterNameread-onlymandatoryThe filter name assiciated with this trap.
1.3.6.1.4.1.2637.2.5.13ScalartrapTempCurrentread-onlymandatoryCurrent temperature in degrees Celsius.
1.3.6.1.4.1.2637.2.5.14ScalartrapTempConfigWarningLevelread-onlymandatoryConfigured warning level temperature in degrees Celsius.
1.3.6.1.4.1.2637.2.5.15ScalartrapSessionIdread-onlymandatoryA session id number associated with the trap.
1.3.6.1.4.1.2637.2.5.16ScalartrapVpopIdread-onlymandatoryA VPOP (Virtual Point of Presence) id associated with the trap.
1.3.6.1.4.1.2637.2.5.17ScalartrapModemCountread-onlymandatoryThe number of available modems.