ARISTA-EXTERNAL-ALARM-MIB

21 objects
The MIB module for reporting the configuration and status of all external alarms present on an Arista device.
Imported Objects
ARISTA-SMI-MIBaristaMibs
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIMODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32
SNMPv2-TCDisplayString TimeStamp TruthValue
OIDNameAccessStatusDescription
1.3.6.1.4.1.30065.3.25IdentityaristaExternalAlarmMIBThe MIB module for reporting the configuration and status of all external alarms present on an Arista device.
1.3.6.1.4.1.30065.3.25.0NodearistaExternalAlarmMibNotifications
1.3.6.1.4.1.30065.3.25.0.1NotificationaristaExternalAlarmAssertedNotifcurrentThis trap signifies that the alarm's status has changed to asserted.
1.3.6.1.4.1.30065.3.25.0.2NotificationaristaExternalAlarmDeassertedNotifcurrentThis trap signifies that the alarm's status has changed to deasserted.
1.3.6.1.4.1.30065.3.25.1NodearistaExternalAlarmMibObjects
1.3.6.1.4.1.30065.3.25.1.1TablearistaExternalAlarmTablenot-accessiblecurrentA list of external alarm entries. There is one entry for each external alarm input present on the system.
1.3.6.1.4.1.30065.3.25.1.1.1RowaristaExternalAlarmTableEntrynot-accessiblecurrentAn entry containing configuration and status information for an external alarm.
1.3.6.1.4.1.30065.3.25.1.1.1.1ColumnaristaExternalAlarmIdnot-accessiblecurrentThe numerical index of the alarm.
1.3.6.1.4.1.30065.3.25.1.1.1.2ColumnaristaExternalAlarmAssertedread-onlycurrentThe current status of the alarm. This attribute has value 'true(1)' if the alarm is enabled and asserted; otherwise, the value is 'false(2)'.
1.3.6.1.4.1.30065.3.25.1.1.1.3ColumnaristaExternalAlarmCountread-onlycurrentThe number of times the alarm has asserted.
1.3.6.1.4.1.30065.3.25.1.1.1.4ColumnaristaExternalAlarmLastAssertedread-onlycurrentThe value of sysUpTime at which the alarm most recently asserted. A value of 0 means the alarm has not asserted.
1.3.6.1.4.1.30065.3.25.1.1.1.5ColumnaristaExternalAlarmLastDeassertedread-onlycurrentThe value of sysUpTime at which the alarm most recently deasserted. A value of 0 means the alarm has not deasserted.
1.3.6.1.4.1.30065.3.25.1.1.1.6ColumnaristaExternalAlarmDescriptionread-onlycurrentA description of the alarm.
1.3.6.1.4.1.30065.3.25.1.1.1.7ColumnaristaExternalAlarmPolarityread-onlycurrentThe current polarity of the alarm. This attribute has value 'open(1)' if the alarm relay is normally open; otherwise, if the polarity is 'closed(2)', the relay…
1.3.6.1.4.1.30065.3.25.1.1.1.8ColumnaristaExternalAlarmActionread-onlycurrentThe configured response to alarm status changes. This attribute has value 'ignore(1)' if alarms are ignored, 'syslog(2)' if system log messages are generated o…
1.3.6.1.4.1.30065.3.25.2NodearistaExternalAlarmMibConformance
1.3.6.1.4.1.30065.3.25.2.1NodearistaExternalAlarmMibCompliances
1.3.6.1.4.1.30065.3.25.2.1.1CompliancearistaExternalAlarmMibCompliancecurrentThe compliance statement for Arista switches that implement the ARISTA-EXTERNAL-ALARM-MIB.
1.3.6.1.4.1.30065.3.25.2.2NodearistaExternalAlarmMibGroups
1.3.6.1.4.1.30065.3.25.2.2.1GrouparistaExternalAlarmObjectsGroupcurrentThe collection of objects that provide information for the external alarms in the system.
1.3.6.1.4.1.30065.3.25.2.2.2GrouparistaExternalAlarmNotificationsGroupcurrentThe collection of notifications generated by the system when an alarm is asserted or deasserted.