ARRIS-D5-SOFTWARE-MGR-MIB
39 objects
This MIB manages the software on the ARRIS EdgeQAM products
Imported Objects
| ARRIS-MIB | arrisD5UEQam |
| SNMPv2-CONF | MODULE-COMPLIANCE OBJECT-GROUP |
| SNMPv2-SMI | enterprises Integer32 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE Unsigned32 |
| SNMPv2-TC | DateAndTime TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4115.1.8.1.10 | IdentitysoftwareManagerMIB | This MIB manages the software on the ARRIS EdgeQAM products | ||
| 1.3.6.1.4.1.4115.1.8.1.10.1 | NodesmControlGroup | |||
| 1.3.6.1.4.1.4115.1.8.1.10.1.1 | ScalarsmReloadAction | read-write | current | Force a reload of the ARRIS product. The command is applied to both WANs when equipped. The load marked as boot in the Software Table will be loaded. nil(1) - … |
| 1.3.6.1.4.1.4115.1.8.1.10.1.2 | ScalarsmConfigFileAction | read-write | current | Perform various actions on the configuration file, as directed below. nil(1) - Do nothing saveRunningConfig(2) - Copies the running configuration to the startu… |
| 1.3.6.1.4.1.4115.1.8.1.10.2 | NodesmSoftwareListGroup | |||
| 1.3.6.1.4.1.4115.1.8.1.10.2.1 | TablesmSoftwareListTable | not-accessible | current | Table of images installed on the flash disk |
| 1.3.6.1.4.1.4115.1.8.1.10.2.1.1 | RowsmSoftwareListEntry | not-accessible | current | . |
| 1.3.6.1.4.1.4115.1.8.1.10.2.1.1.1 | ColumnsmSoftwareEntryIndex | not-accessible | current | image index |
| 1.3.6.1.4.1.4115.1.8.1.10.2.1.1.2 | ColumnsmSoftwareEntryFilename | read-only | current | Name of the image file |
| 1.3.6.1.4.1.4115.1.8.1.10.2.1.1.3 | ColumnsmSoftwareEntryVersion | read-only | current | image version |
| 1.3.6.1.4.1.4115.1.8.1.10.2.1.1.4 | ColumnsmSoftwareEntryDate | read-only | current | Date image created |
| 1.3.6.1.4.1.4115.1.8.1.10.2.1.1.5 | ColumnsmSoftwareEntryState | read-only | current | State of the load file. valid means the software load has been properly downloaded and can be loaded onto the system. corrupt means there was a problem tranfer… |
| 1.3.6.1.4.1.4115.1.8.1.10.2.1.1.6 | ColumnsmSoftwareEntrySize | read-only | current | file size |
| 1.3.6.1.4.1.4115.1.8.1.10.2.1.1.7 | ColumnsmSoftwareEntryStatus | read-only | current | Status of software may be running-boot, running, boot or inactive running-boot(1) indicates that the load is running AND is the boot load. running(2) means the… |
| 1.3.6.1.4.1.4115.1.8.1.10.2.1.1.8 | ColumnsmSoftwareEntryAction | read-write | current | Perform an action on this software load entry. To make the current software load the boot load, select makeBoot(2). When set to upload(3), this software load w… |
| 1.3.6.1.4.1.4115.1.8.1.10.3 | NodesmConfigFileListGroup | |||
| 1.3.6.1.4.1.4115.1.8.1.10.3.1 | TablesmConfigFileListTable | not-accessible | current | Table of configuration files or scripts on flash disk |
| 1.3.6.1.4.1.4115.1.8.1.10.3.1.1 | RowsmConfigFileListEntry | not-accessible | current | . |
| 1.3.6.1.4.1.4115.1.8.1.10.3.1.1.1 | ColumnsmConfigFileEntryIndex | not-accessible | current | image index |
| 1.3.6.1.4.1.4115.1.8.1.10.3.1.1.2 | ColumnsmConfigFileEntryName | read-only | current | Name of the file |
| 1.3.6.1.4.1.4115.1.8.1.10.3.1.1.3 | ColumnsmConfigFileTimestamp | read-only | current | Timestamp of the configuration file |
| 1.3.6.1.4.1.4115.1.8.1.10.3.1.1.4 | ColumnsmConfigFileEntryAction | read-write | current | Actions to perform on the current configuration file. To make this configuration file the startup configuration file, select makeStartupConfig(2). Be sure not … |
| 1.3.6.1.4.1.4115.1.8.1.10.4 | NodesmSoftwareTransferGroup | |||
| 1.3.6.1.4.1.4115.1.8.1.10.4.1 | ScalarsmSoftwareTransferDevice | read-write | current | Specify protocol to use for software load transfers |
| 1.3.6.1.4.1.4115.1.8.1.10.4.2 | ScalarsmSoftwareTransferHostname | read-write | current | Server ip address or hostname |
| 1.3.6.1.4.1.4115.1.8.1.10.4.3 | ScalarsmSoftwareTransferUsername | read-write | current | Server user name |
| 1.3.6.1.4.1.4115.1.8.1.10.4.4 | ScalarsmSoftwareTransferPassword | read-write | current | Server user password |
| 1.3.6.1.4.1.4115.1.8.1.10.4.5 | ScalarsmSoftwareTransferPath | read-write | current | Path and filename for image file on tftp, ftp or nfs |
| 1.3.6.1.4.1.4115.1.8.1.10.4.6 | ScalarsmSoftwareTransferControl | read-write | current | Control the transfer as follows: abort(1) - Will abort the transfer in progress. download(2) - Starts a transfer to the ARRIS device upload(3) - Transfer speci… |
| 1.3.6.1.4.1.4115.1.8.1.10.4.7 | ScalarsmSoftwareTransferStatus | read-only | current | Indication of the last transfer attempt as follows: none(1) indicates no images have been transferred since the system rebooted. inprogress(2) - Indicates ther… |
| 1.3.6.1.4.1.4115.1.8.1.10.5 | NodesmConfigFileTransferGroup | |||
| 1.3.6.1.4.1.4115.1.8.1.10.5.1 | ScalarsmConfigFileTransferDevice | read-write | current | Specify protocol to use for file transfers |
| 1.3.6.1.4.1.4115.1.8.1.10.5.2 | ScalarsmConfigFileTransferHostname | read-write | current | Server ip address or hostname |
| 1.3.6.1.4.1.4115.1.8.1.10.5.3 | ScalarsmConfigFileTransferUsername | read-write | current | Server user name |
| 1.3.6.1.4.1.4115.1.8.1.10.5.4 | ScalarsmConfigFileTransferPassword | read-write | current | Server user password |
| 1.3.6.1.4.1.4115.1.8.1.10.5.5 | ScalarsmConfigFileTransferPath | read-write | current | Path and filename of the configuration file on the source device. |
| 1.3.6.1.4.1.4115.1.8.1.10.5.6 | ScalarsmConfigFileTransferTargetPath | read-write | current | Path and filename of the configuration file on the target device. |
| 1.3.6.1.4.1.4115.1.8.1.10.5.7 | ScalarsmConfigFileTransferControl | read-write | current | Control the transfer as follows: abort(1) - Will abort the transfer in progress. download(2) - Starts a transfer to the ARRIS device upload(3) - Transfer speci… |
| 1.3.6.1.4.1.4115.1.8.1.10.5.8 | ScalarsmConfigFileTransferStatus | read-only | current | Indication of the last transfer attempt as follows: none(1) indicates no files have been transferred since the system rebooted. inprogress(2) - Indicates there… |