ASCEND-ADSL-CAP-MIB
31 objects
No module-level DESCRIPTION found.
Imported Objects
| ASCEND-WAN-MIB | wanTypeAdslCap |
| RFC-1212 | OBJECT-TYPE |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.529.4.9.1 | TableadslCapLineStatusTable | not-accessible | mandatory | ADSL CAP status parameters. |
| 1.3.6.1.4.1.529.4.9.1.1 | RowadslCapLineStatusEntry | not-accessible | mandatory | A interface status entry containing objects to describe the interface. |
| 1.3.6.1.4.1.529.4.9.1.1.1 | ColumnadslCapStatusIfEntryIndex | read-only | mandatory | Index into the Status Table via the interface group ifIndex value. |
| 1.3.6.1.4.1.529.4.9.1.1.2 | ColumnadslCapStatusShelfIndex | read-only | mandatory | TNT's ADSL CAP modules Shelf ID. |
| 1.3.6.1.4.1.529.4.9.1.1.3 | ColumnadslCapStatusSlotIndex | read-only | mandatory | TNT's ADSL CAP modules Slot ID. |
| 1.3.6.1.4.1.529.4.9.1.1.4 | ColumnadslCapStatusLineIndex | read-only | mandatory | ADSL CAP modules line ID. |
| 1.3.6.1.4.1.529.4.9.1.1.5 | ColumnadslCapStatusUnitType | read-only | mandatory | Unit type defines if the unit is operating either as a Central Office Equipment (COE) or Customer Premiss equipment (CPE). |
| 1.3.6.1.4.1.529.4.9.1.1.6 | ColumnadslCapStatusLineState | read-only | mandatory | Interface state describes the current ports operating state. States are: Config, Pend Down, Up, Down, Start-up, or N/A. |
| 1.3.6.1.4.1.529.4.9.1.1.7 | ColumnadslCapStatusUpRate | read-write | mandatory | When parameter is read, it displays the current up stream (cpe to coe) rate which can differ from the written value. |
| 1.3.6.1.4.1.529.4.9.1.1.8 | ColumnadslCapStatusDownRate | read-write | mandatory | When parameter is read, it displays the current down stream (coe to cpe) rate which can differ from the written value. |
| 1.3.6.1.4.1.529.4.9.1.1.9 | ColumnadslCapStatusVendorId | read-only | mandatory | Vendor identification. |
| 1.3.6.1.4.1.529.4.9.1.1.10 | ColumnadslCapStatusMajorFirmWareVer | read-only | mandatory | Major firmware version. |
| 1.3.6.1.4.1.529.4.9.1.1.11 | ColumnadslCapStatusMinorFirmWareVer | read-only | mandatory | Minor firmware version. |
| 1.3.6.1.4.1.529.4.9.1.1.12 | ColumnadslCapStatusHardWareVer | read-only | mandatory | Hardware version. |
| 1.3.6.1.4.1.529.4.9.2 | TableadslCapLineStatisticTable | not-accessible | mandatory | ADSL CAP statistical parameters. |
| 1.3.6.1.4.1.529.4.9.2.1 | RowadslCapLineStatisticEntry | not-accessible | mandatory | A interface statistical entry containing objects to describe the interface. |
| 1.3.6.1.4.1.529.4.9.2.1.1 | ColumnadslCapStatIfEntryIndex | read-only | mandatory | Index into the Status Table via the interface group ifIndex value. |
| 1.3.6.1.4.1.529.4.9.2.1.2 | ColumnadslCapStatShelfIndex | read-only | mandatory | ADSL CAP modules Shelf ID. |
| 1.3.6.1.4.1.529.4.9.2.1.3 | ColumnadslCapStatSlotIndex | read-only | mandatory | ADSL CAP modules Slot ID. |
| 1.3.6.1.4.1.529.4.9.2.1.4 | ColumnadslCapStatLineIndex | read-only | mandatory | ADSL CAP modules interface ID. |
| 1.3.6.1.4.1.529.4.9.2.1.5 | ColumnadslCapStatConnUpDays | read-only | mandatory | Connection up day count. |
| 1.3.6.1.4.1.529.4.9.2.1.6 | ColumnadslCapStatConnUpHours | read-only | mandatory | Connection Up 24 hour count. |
| 1.3.6.1.4.1.529.4.9.2.1.7 | ColumnadslCapStatConnUpMinutes | read-only | mandatory | Connection up minute count. |
| 1.3.6.1.4.1.529.4.9.2.1.8 | ColumnadslCapStatRxSignalPresent | read-only | mandatory | Receive signal present detection. |
| 1.3.6.1.4.1.529.4.9.2.1.9 | ColumnadslCapStatLineQualityDb | read-only | mandatory | Lines noise margin. Reliable data will transfer with a reading of -5db or greater. |
| 1.3.6.1.4.1.529.4.9.2.1.10 | ColumnadslCapStatUpDwnCntr | read-only | mandatory | Line Up Down counter value displays the number of times the interface transitions from a down to up state. |
| 1.3.6.1.4.1.529.4.9.2.1.11 | ColumnadslCapStatLineSelfTest | read-only | mandatory | Line hardware self test results (Passed or Failed). |
| 1.3.6.1.4.1.529.4.9.2.1.12 | ColumnadslCapStatBertTimer | read-write | mandatory | BER test duration configuration. When two nodes are physically connected, the BER test lasts for the duration of this timer. |
| 1.3.6.1.4.1.529.4.9.2.1.13 | ColumnadslCapStatBertEna | read-write | mandatory | Enable/disable of the BER test. If nodes are connected, then the BER test is ran between the units. If this node is not connected to a remote node, then the in… |
| 1.3.6.1.4.1.529.4.9.2.1.14 | ColumnadslCapStatBertState | read-only | mandatory | BER test states. When this node is not connected to anyother node, then the state enters local-loop-active. When two nodes are conneced then different states a… |
| 1.3.6.1.4.1.529.4.9.2.1.15 | ColumnadslCapStatBertErrorCounter | read-only | mandatory | BER test bit error counter. |