MIB Viewer

ASCEND-MIBCLTM-MIB

51 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.529.23.66NodemibcltmCmd
1.3.6.1.4.1.529.23.66.1TablemibcltmCmdTablenot-accessiblemandatoryA list of mibcltmCmd profile entries.
1.3.6.1.4.1.529.23.66.1.1RowmibcltmCmdEntrynot-accessiblemandatoryA mibcltmCmd entry containing objects that maps to the parameters of mibcltmCmd profile.
1.3.6.1.4.1.529.23.66.1.1.1ColumncltmCmd-Index-oread-onlymandatory
1.3.6.1.4.1.529.23.66.1.1.2ColumncltmCmd-CltmSlotread-onlymandatoryIdentify the CLTM slot within the system.
1.3.6.1.4.1.529.23.66.1.1.3ColumncltmCmd-TestTimeStampread-onlymandatoryValue of the sysUpTime when the last test command was issued. This parameter is cleared when any of the test parameters are changed.
1.3.6.1.4.1.529.23.66.1.1.4ColumncltmCmd-TestSequenceread-onlymandatorySequence of the last issued test command.
1.3.6.1.4.1.529.23.66.1.1.5ColumncltmCmd-TestOperationread-writemandatoryThe current operation that is active on the CLT Module. Defaultls to 'none'. Set to 'none' to stop the test procedure.
1.3.6.1.4.1.529.23.66.1.1.6ColumncltmCmd-DmmTyperead-writemandatoryDMM Measurement Type.
1.3.6.1.4.1.529.23.66.1.1.7ColumncltmCmd-DmmLeadread-writemandatoryDMM Measurement Leads.
1.3.6.1.4.1.529.23.66.1.1.8ColumncltmCmd-BackgroundNoiseFilterread-writemandatoryLine Filter Type for Background Noise Test.
1.3.6.1.4.1.529.23.66.1.1.9ColumncltmCmd-BackgroundNoiseTerminationread-writemandatoryLine Termination Type for Background Noise Test.
1.3.6.1.4.1.529.23.66.1.1.10ColumncltmCmd-LoopResistanceUnitread-writemandatoryMeasurement System for Loop Resistance Test.
1.3.6.1.4.1.529.23.66.1.1.11ColumncltmCmd-LoopResistanceTempread-writemandatoryLine Temperature for Loop Resistance Test. Assigned in degree celsius/fahrenheit.
1.3.6.1.4.1.529.23.66.1.1.12ColumncltmCmd-ImpulseNoiseStartThreshread-writemandatoryThreshold for Impulse Noise Test. The Range is 50-100 dBrm.
1.3.6.1.4.1.529.23.66.1.1.13ColumncltmCmd-ImpulseNoiseStartDeltaread-writemandatoryDelta Value for Impulse Noise Test. The delta range is 2-6 dB
1.3.6.1.4.1.529.23.66.1.1.14ColumncltmCmd-ImpulseNoiseStartMaxCountread-writemandatoryMax Count for Impulse Noise Test. The range of the value is 1-1999.
1.3.6.1.4.1.529.23.66.1.1.15ColumncltmCmd-ImpulseNoiseStartDeadTimeread-writemandatoryDead Time Value for Impulse Noise Start Test. The value is assigned in 0.1 ms increments.
1.3.6.1.4.1.529.23.66.1.1.16ColumncltmCmd-ImpulseNoiseStartTimerread-writemandatoryTimer values for Impulse Noise Start Test. The value is assigned in 1 minute increment.
1.3.6.1.4.1.529.23.66.1.1.17ColumncltmCmd-CalibrationTyperead-writemandatoryCalibration Type
1.3.6.1.4.1.529.23.66.1.1.18ColumncltmCmd-ToneSendFreqread-writemandatoryTone Send Frequency in KHz.
1.3.6.1.4.1.529.23.66.1.1.19ColumncltmCmd-ToneSendLevelread-writemandatoryTone Send Level in dBm.
1.3.6.1.4.1.529.23.66.1.1.20ColumncltmCmd-ToneSendPeriodread-writemandatoryAmount of time a tone is sent (1-20 Minutes).
1.3.6.1.4.1.529.23.66.1.1.21ColumncltmCmd-TdrUnitread-writemandatoryMeasurement System for TDR Test.
1.3.6.1.4.1.529.23.66.1.1.22ColumncltmCmd-TdrGaugeread-writemandatoryTDR gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system.
1.3.6.1.4.1.529.23.66.1.1.23ColumncltmCmd-TdrVpread-writemandatoryTDR VP as percentage of the speed of light.
1.3.6.1.4.1.529.23.66.1.1.24ColumncltmCmd-TdrAvgread-writemandatoryNumber of trials to get the avarage.
1.3.6.1.4.1.529.23.66.1.1.25ColumncltmCmd-TdrGetTyperead-writemandatoryTDR Test Range Measurement Type. If set to automatic cltmCmdTdrStartLen and cltmCmdTdrMeasureLen do not need to be set.
1.3.6.1.4.1.529.23.66.1.1.26ColumncltmCmd-TdrStartDistanceread-writemandatoryTDR Start Length for MANUAL mode, the value is given in feet (15..20000) for the English system and cm (460..609750) for the metric system.
1.3.6.1.4.1.529.23.66.1.1.27ColumncltmCmd-TdrMeasurementLengthread-writemandatoryTDR Measurement Length for MANUAL mode, the value is given in feet (300..20000) for the English system and cm (9150..609750) for the metric system.
1.3.6.1.4.1.529.23.66.1.1.28ColumncltmCmd-DmmdcdPeriodread-writemandatoryAmount of time measurement is made (0,1-5 100ms;0=MAX).
1.3.6.1.4.1.529.23.66.1.1.29ColumncltmCmd-DmmdcdVoltageread-writemandatoryTest voltage to be used (-230 to 230 Volts).
1.3.6.1.4.1.529.23.66.1.1.30ColumncltmCmd-DmmdcdImpedanceread-writemandatoryOutput Impedance to be used (10 to 1000 Kohms).
1.3.6.1.4.1.529.23.66.1.1.31ColumncltmCmd-DmmcapPeriodread-writemandatoryAmount of time measurement is made (0,1-5 100ms;0=MAX).
1.3.6.1.4.1.529.23.66.1.1.32ColumncltmCmd-DmmallTyperead-writemandatoryDMM Measurement Type.
1.3.6.1.4.1.529.23.66.1.1.33ColumncltmCmd-DmmallPeriodread-writemandatoryAmount of time measurement is made (0,1-5 100ms;0=MAX).
1.3.6.1.4.1.529.23.66.1.1.34ColumncltmCmd-DmmallInputImpread-writemandatoryInput Impedance (100, 1000 Kohm).
1.3.6.1.4.1.529.23.66.1.1.35ColumncltmCmd-CtoneTyperead-writemandatoryControl tone, type of DSL service (ADSL, GLITE).
1.3.6.1.4.1.529.23.66.1.1.36ColumncltmCmd-CtoneToneread-writemandatoryControl tone, type of Tone (QUIET, RESTORE).
1.3.6.1.4.1.529.23.66.1.1.37ColumncltmCmd-TtoneLeadread-writemandatorytrace tone, Measurement Leads.
1.3.6.1.4.1.529.23.66.1.1.38ColumncltmCmd-TtoneLevelread-writemandatorytrace tone, Tone Send Level in dBm.
1.3.6.1.4.1.529.23.66.1.1.39ColumncltmCmd-TtonePeriodread-writemandatorytrace tone, Amount of time a tone is sent (1-20 Minutes).
1.3.6.1.4.1.529.23.66.1.1.40ColumncltmCmd-BtapStartLengthread-writemandatoryMeasurement start length (15 - 20000 ft. or 5 - 6097 meter).
1.3.6.1.4.1.529.23.66.1.1.41ColumncltmCmd-BtapMeasureLengthread-writemandatoryMeasurement length (100 - 20000 ft. or 32 - 6097 meter).
1.3.6.1.4.1.529.23.66.1.1.42ColumncltmCmd-Action-oread-writemandatory
1.3.6.1.4.1.529.23.66.1.1.43ColumncltmCmd-FcllocUnitread-writemandatoryMeasurement System for FCLLOC Test.
1.3.6.1.4.1.529.23.66.1.1.44ColumncltmCmd-FcllocGaugeread-writemandatoryFCLLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system.
1.3.6.1.4.1.529.23.66.1.1.45ColumncltmCmd-ShortlocUnitread-writemandatoryMeasurement System for SHORTLOC Test.
1.3.6.1.4.1.529.23.66.1.1.46ColumncltmCmd-ShortlocGaugeread-writemandatorySHORTLOC gauge. This is either 22/24/26 AWG for English system or 6/5/4 (0.1mm) for the metric system.
1.3.6.1.4.1.529.23.66.1.1.47ColumncltmCmd-ShortlocTyperead-writemandatorySHORTLOC test type.
Type Definitions
NameSyntaxStatusDescription
DisplayStringOCTET STRING