ASCEND-MIBDBA-MIB
55 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.529.23.71 | NodemibdBAProfile | |||
| 1.3.6.1.4.1.529.23.71.1 | TablemibdBAProfileTable | not-accessible | mandatory | A list of mibdBAProfile profile entries. |
| 1.3.6.1.4.1.529.23.71.1.1 | RowmibdBAProfileEntry | not-accessible | mandatory | A mibdBAProfile entry containing objects that maps to the parameters of mibdBAProfile profile. |
| 1.3.6.1.4.1.529.23.71.1.1.1 | ColumndBAProfile-Shelf-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.71.1.1.2 | ColumndBAProfile-Slot-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.71.1.1.3 | ColumndBAProfile-Item-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.71.1.1.4 | ColumndBAProfile-LogicalItem-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.71.1.1.5 | ColumndBAProfile-LogicalAddress-PhysicalAddress-Shelf | read-write | mandatory | The number of the shelf that the addressed physical device resides on. |
| 1.3.6.1.4.1.529.23.71.1.1.6 | ColumndBAProfile-LogicalAddress-PhysicalAddress-Slot | read-write | mandatory | The number of the slot that the addressed physical device resides on. |
| 1.3.6.1.4.1.529.23.71.1.1.7 | ColumndBAProfile-LogicalAddress-PhysicalAddress-ItemNumber | read-write | mandatory | A number that specifies an addressable entity within the context of shelf and slot. |
| 1.3.6.1.4.1.529.23.71.1.1.8 | ColumndBAProfile-LogicalAddress-LogicalItem | read-write | mandatory | A number that specifies an addressable logical entity within the context of a physical address. |
| 1.3.6.1.4.1.529.23.71.1.1.9 | ColumndBAProfile-Name | read-write | mandatory | DBA Profiles are recognized by their names given them by the user. The name is a standard null terminated ASCII string. |
| 1.3.6.1.4.1.529.23.71.1.1.10 | ColumndBAProfile-PhoneNumber | read-write | mandatory | The number to dial for this call. |
| 1.3.6.1.4.1.529.23.71.1.1.11 | ColumndBAProfile-BillingNumber | read-write | mandatory | The billing number to use which is either a 'calling party number' or a 'billing suffix' that is appended to the end of the phone number. |
| 1.3.6.1.4.1.529.23.71.1.1.12 | ColumndBAProfile-oCallType | read-write | mandatory | session channel type. |
| 1.3.6.1.4.1.529.23.71.1.1.13 | ColumndBAProfile-oCallMgm | read-write | mandatory | One of the management type listed above. |
| 1.3.6.1.4.1.529.23.71.1.1.14 | ColumndBAProfile-oDataSvc | read-write | mandatory | The type of bearer channel capability to set up for each switched call in the session. |
| 1.3.6.1.4.1.529.23.71.1.1.15 | ColumndBAProfile-Force56 | read-write | mandatory | TRUE if the data should be treated as 7-bit data even if the switchedCallType would normally imply 8 bit data. |
| 1.3.6.1.4.1.529.23.71.1.1.16 | ColumndBAProfile-BaseChannelCount | read-write | mandatory | When the session is initially set up, and if it is a fixed session, the number of channels to be used for the call. |
| 1.3.6.1.4.1.529.23.71.1.1.17 | ColumndBAProfile-IncrementChannelCount | read-write | mandatory | Number of channels to increment as a block. |
| 1.3.6.1.4.1.529.23.71.1.1.18 | ColumndBAProfile-DecrementChannelCount | read-write | mandatory | Number of channels to decrement as a block. |
| 1.3.6.1.4.1.529.23.71.1.1.19 | ColumndBAProfile-oFailAction | read-write | mandatory | If unable to establish a dba session based on the parameters specified, then the action to be taken is specified in the failureAction. |
| 1.3.6.1.4.1.529.23.71.1.1.20 | ColumndBAProfile-BitInversionRequired | read-write | mandatory | TRUE if the data being transferred from the host should be inverted before being sent to the network, and FALSE otherwise. I think this needs to be supported b… |
| 1.3.6.1.4.1.529.23.71.1.1.21 | ColumndBAProfile-Ft1Caller | read-write | mandatory | BOOLEAN which is true for Fractional T1 calls when this side is the caller, and FALSE otherwise. |
| 1.3.6.1.4.1.529.23.71.1.1.22 | ColumndBAProfile-Ft1Timeout | read-write | mandatory | |
| 1.3.6.1.4.1.529.23.71.1.1.23 | ColumndBAProfile-CallByCallID | read-write | mandatory | The ID for the call-by-call signalling for PRI. |
| 1.3.6.1.4.1.529.23.71.1.1.24 | ColumndBAProfile-CalledNumberType | read-write | mandatory | Indication of whether national number, international number, etc. is specified. |
| 1.3.6.1.4.1.529.23.71.1.1.25 | ColumndBAProfile-UnknownPlanUnknown | read-write | mandatory | If TRUE indicates that UNKNOWN number plan is used in conjunction with unknown number instead of default, ISDN. |
| 1.3.6.1.4.1.529.23.71.1.1.26 | ColumndBAProfile-LocalPlanIsdn | read-write | mandatory | If TRUE indicates that ISDN number plan is used in conjunction with local number instead of default, PRIVATE. |
| 1.3.6.1.4.1.529.23.71.1.1.27 | ColumndBAProfile-TransitNumber | read-write | mandatory | The string for use in the 'transit network ie' for PRI calling when going through a LEC. |
| 1.3.6.1.4.1.529.23.71.1.1.28 | ColumndBAProfile-oAutoBERT | read-write | mandatory | Should we BERT at session startup and for how long. |
| 1.3.6.1.4.1.529.23.71.1.1.29 | ColumndBAProfile-TimedCall | read-write | mandatory | TRUE if we should pay attention to the following time period parameters. Not used when the call type is dynamic N-by. |
| 1.3.6.1.4.1.529.23.71.1.1.30 | ColumndBAProfile-FlagIdle | read-write | mandatory | TRUE if looking for flag idle, FALSE when looking for mark idle. |
| 1.3.6.1.4.1.529.23.71.1.1.31 | ColumndBAProfile-oDynAlg | read-write | mandatory | The algorithm to use for determining weighted line utilization. |
| 1.3.6.1.4.1.529.23.71.1.1.32 | ColumndBAProfile-SecondsOfHistory | read-write | mandatory | Number of seconds to keep history data around for. This number is in the range of 1 through MAX_HISTORY_SECONDS. |
| 1.3.6.1.4.1.529.23.71.1.1.33 | ColumndBAProfile-AddSecondsOfPersistence | read-write | mandatory | Once the upper threshold of utilization is passed, the number of seconds it should stay there is defined here. |
| 1.3.6.1.4.1.529.23.71.1.1.34 | ColumndBAProfile-RemoveSecondsOfPersistence | read-write | mandatory | Once the lower threshold of utilization is passed, the number of seconds it should stay there is defined here. |
| 1.3.6.1.4.1.529.23.71.1.1.35 | ColumndBAProfile-NailedUpGroup | read-write | mandatory | Nailed-up group letter. This is a group or number field as defined in lcdparam.h. |
| 1.3.6.1.4.1.529.23.71.1.1.36 | ColumndBAProfile-CallPassword | read-write | mandatory | DBA call password authenticated against port's password on receiver side. Ignored if port's password is not defined. |
| 1.3.6.1.4.1.529.23.71.1.1.37 | ColumndBAProfile-DbaPriNumberingPlanId | read-write | mandatory | PRI Called Party element's Numbering-Plan-ID value for outgoing T1-to-PRI calls. |
| 1.3.6.1.4.1.529.23.71.1.1.38 | ColumndBAProfile-Action-o | read-write | mandatory | |
| 1.3.6.1.4.1.529.23.71.2 | TablemibdBAProfile-TimerPeriodParametersTable | not-accessible | mandatory | A list of mibdBAProfile__timer_period_parameters profile entries. |
| 1.3.6.1.4.1.529.23.71.2.1 | RowmibdBAProfile-TimerPeriodParametersEntry | not-accessible | mandatory | A mibdBAProfile__timer_period_parameters entry containing objects that maps to the parameters of mibdBAProfile__timer_period_parameters profile. |
| 1.3.6.1.4.1.529.23.71.2.1.1 | ColumndBAProfile-TimerPeriodParameters-Shelf-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.71.2.1.2 | ColumndBAProfile-TimerPeriodParameters-Slot-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.71.2.1.3 | ColumndBAProfile-TimerPeriodParameters-Item-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.71.2.1.4 | ColumndBAProfile-TimerPeriodParameters-LogicalItem-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.71.2.1.5 | ColumndBAProfile-TimerPeriodParameters-Index-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.71.2.1.6 | ColumndBAProfile-TimerPeriodParameters-oActiv | read-write | mandatory | Like the other sub-structures above, the number of time-periods actually used is variable. Therefore, this is an indication within each structure of usage. |
| 1.3.6.1.4.1.529.23.71.2.1.7 | ColumndBAProfile-TimerPeriodParameters-StartingTime | read-write | mandatory | Each time period has a starting time, and an ending time (which is implicit by the next starting time specified in another structure). The starting time is spe… |
| 1.3.6.1.4.1.529.23.71.2.1.8 | ColumndBAProfile-TimerPeriodParameters-MinimumChannelCount | read-write | mandatory | The smallest number of channels to use during this time period. |
| 1.3.6.1.4.1.529.23.71.2.1.9 | ColumndBAProfile-TimerPeriodParameters-MaximumChannelCount | read-write | mandatory | The maximum number of channels to use during this time period. |
| 1.3.6.1.4.1.529.23.71.2.1.10 | ColumndBAProfile-TimerPeriodParameters-TargetUtilization | read-write | mandatory | The percentage utilization to aim for. This is used as a parameter to the bandwidth heuristics. |
| 1.3.6.1.4.1.529.23.71.2.1.11 | ColumndBAProfile-TimerPeriodParameters-X25chanTargetUtilization | read-write | mandatory | The percentage utilization to aim for. This is used as a parameter to the bandwidth heuristics. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DisplayString | OCTET STRING |