MIB Viewer

ASCEND-MIBHDSL2NET-MIB

50 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.529.23.14Nodemibhdsl2NetworkProfile
1.3.6.1.4.1.529.23.14.1Tablemibhdsl2NetworkProfileTablenot-accessiblemandatoryA list of mibhdsl2NetworkProfile profile entries.
1.3.6.1.4.1.529.23.14.1.1Rowmibhdsl2NetworkProfileEntrynot-accessiblemandatoryA mibhdsl2NetworkProfile entry containing objects that maps to the parameters of mibhdsl2NetworkProfile profile.
1.3.6.1.4.1.529.23.14.1.1.1Columnhdsl2NetworkProfile-Shelf-oread-onlymandatory
1.3.6.1.4.1.529.23.14.1.1.2Columnhdsl2NetworkProfile-Slot-oread-onlymandatory
1.3.6.1.4.1.529.23.14.1.1.3Columnhdsl2NetworkProfile-Item-oread-onlymandatory
1.3.6.1.4.1.529.23.14.1.1.4Columnhdsl2NetworkProfile-Nameread-writemandatoryFor future use. The current design does not use the name field but instead references Hdsl2 lines by the physical address; we may in the future support referen…
1.3.6.1.4.1.529.23.14.1.1.5Columnhdsl2NetworkProfile-PhysicalAddress-Shelfread-writemandatoryThe number of the shelf that the addressed physical device resides on.
1.3.6.1.4.1.529.23.14.1.1.6Columnhdsl2NetworkProfile-PhysicalAddress-Slotread-writemandatoryThe number of the slot that the addressed physical device resides on.
1.3.6.1.4.1.529.23.14.1.1.7Columnhdsl2NetworkProfile-PhysicalAddress-ItemNumberread-writemandatoryA number that specifies an addressable entity within the context of shelf and slot.
1.3.6.1.4.1.529.23.14.1.1.8Columnhdsl2NetworkProfile-Enabledread-writemandatoryTRUE if the line is enabled, otherwise FALSE.
1.3.6.1.4.1.529.23.14.1.1.9Columnhdsl2NetworkProfile-ProfileNumberread-writemandatoryFor potential backwards compatibility. The current design consists of one line profile numbered 0.
1.3.6.1.4.1.529.23.14.1.1.10Columnhdsl2NetworkProfile-LineConfig-TrunkGroupread-writemandatoryThe trunk group to which this line is assigned. 0 means this line is not part of a trunk group.
1.3.6.1.4.1.529.23.14.1.1.11Columnhdsl2NetworkProfile-LineConfig-NailedGroupread-writemandatoryA number that identifies the set of lines that makes up a nailed group. 0 means this line is not part of a nailed group.
1.3.6.1.4.1.529.23.14.1.1.12Columnhdsl2NetworkProfile-LineConfig-VpSwitchingVpiread-writemandatoryThe Vpi to be used for the VP switching. Rest of the valid VPIs in valid vpi-vci-range will be used for the VC switching. Changes in this range will take effec…
1.3.6.1.4.1.529.23.14.1.1.13Columnhdsl2NetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumberread-writemandatory
1.3.6.1.4.1.529.23.14.1.1.14Columnhdsl2NetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumberread-writemandatoryTNT is a multi shelf system. To minimise the changes required to existing code the shelf number is added to this structure as it will almost always be needed w…
1.3.6.1.4.1.529.23.14.1.1.15Columnhdsl2NetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumberread-writemandatory
1.3.6.1.4.1.529.23.14.1.1.16Columnhdsl2NetworkProfile-LineConfig-Activationread-writemandatoryLine activation mode.
1.3.6.1.4.1.529.23.14.1.1.17Columnhdsl2NetworkProfile-LineConfig-CallRouteInfo-Shelfread-writemandatoryThe number of the shelf that the addressed physical device resides on.
1.3.6.1.4.1.529.23.14.1.1.18Columnhdsl2NetworkProfile-LineConfig-CallRouteInfo-Slotread-writemandatoryThe number of the slot that the addressed physical device resides on.
1.3.6.1.4.1.529.23.14.1.1.19Columnhdsl2NetworkProfile-LineConfig-CallRouteInfo-ItemNumberread-writemandatoryA number that specifies an addressable entity within the context of shelf and slot.
1.3.6.1.4.1.529.23.14.1.1.20Columnhdsl2NetworkProfile-LineConfig-UnitTyperead-writemandatoryThe Unit Type defines if a line is acting as either a Central Office (COE) or Customer Premise Equipment (CPE). Note that the remote unit needs to be configure…
1.3.6.1.4.1.529.23.14.1.1.23Columnhdsl2NetworkProfile-Action-oread-writemandatory
1.3.6.1.4.1.529.23.14.1.1.24Columnhdsl2NetworkProfile-SparingModeread-writemandatoryPort sparing operational mode for this port.
1.3.6.1.4.1.529.23.14.1.1.25Columnhdsl2NetworkProfile-LineConfig-NtrEnabledread-writemandatoryTRUE if NTR functionality is enabled, otherwise FALSE. If the unit-type is COE, it will take the system clock as the input when NTR is enabled and allow the re…
1.3.6.1.4.1.529.23.14.1.1.26Columnhdsl2NetworkProfile-LineConfig-ClockSourceread-writemandatoryDetermine whether the 8KHz clock from the HDSL2 line (unit-type has to be CPE and ntr-enabled has to be yes) is eligible to be used as the 8KHz system clock so…
1.3.6.1.4.1.529.23.14.1.1.27Columnhdsl2NetworkProfile-LineConfig-ClockPriorityread-writemandatoryClock priority assigned to the HDSL2 line. Used to select a particular HDSL2 line as the 8KHz system clock source.
1.3.6.1.4.1.529.23.14.1.1.28Columnhdsl2NetworkProfile-LineConfig-LoopBackread-writemandatoryConfiguration of different modem loopbacks.
1.3.6.1.4.1.529.23.14.1.1.29Columnhdsl2NetworkProfile-IgnoreLineupread-writemandatoryIgnore line up value for this port.
1.3.6.1.4.1.529.23.14.1.1.30Columnhdsl2NetworkProfile-LineConfig-Marginread-writemandatorySelects a margin range between the signal to noise floor.
1.3.6.1.4.1.529.23.14.1.1.31Columnhdsl2NetworkProfile-LineConfig-RateModeread-writemandatoryUsed for G.SHDSL technology. Selects if the modem operates in Fixed or Auto rate mode.
1.3.6.1.4.1.529.23.14.1.1.32Columnhdsl2NetworkProfile-LineConfig-MinRateread-writemandatoryUsed for G.SHDSL technology. When the rate-mode is set to Auto, this is the minimum rate the modem will train to.
1.3.6.1.4.1.529.23.14.1.1.33Columnhdsl2NetworkProfile-LineConfig-MaxRateread-writemandatoryUsed for G.SHDSL technology. When the rate-mode is set to Auto, this is the maximum rate the modem will train to. When the rate-mode is set to Fixed, this is t…
1.3.6.1.4.1.529.23.14.1.1.34Columnhdsl2NetworkProfile-LineConfig-GshdslStandardNetworkTyperead-writemandatoryPer the G.SHDSL Standard G.991.2. This parameter allows selection for the modem to operate either the North American Annex 'A' or European Annex 'B' standard n…
1.3.6.1.4.1.529.23.14.1.1.35Columnhdsl2NetworkProfile-LineConfig-GshdslPsdTyperead-writemandatoryPer the G.SHDSL Standard G.911.2. This parameter allows selection for the modem to output a symmetric PSD at all rates or asymmetric PSD's at fixed rates of 77…
1.3.6.1.4.1.529.23.14.1.1.36Columnhdsl2NetworkProfile-ThreshProfiles-SpanThreshProfileread-writemandatoryThe name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for all the HDSL2/SHDSL units for this port unles…
1.3.6.1.4.1.529.23.14.1.1.37Columnhdsl2NetworkProfile-ThreshProfiles-XtucThreshProfileread-writemandatoryThe name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the DSLAM.
1.3.6.1.4.1.529.23.14.1.1.38Columnhdsl2NetworkProfile-ThreshProfiles-XturThreshProfileread-writemandatoryThe name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the remote CPE.
1.3.6.1.4.1.529.23.14.1.1.39Columnhdsl2NetworkProfile-LineConfig-SnextMarginread-writemandatorySelects a Snext margin range with a worst-case self next noise model given current loop insertion loss.
1.3.6.1.4.1.529.23.14.1.1.40Columnhdsl2NetworkProfile-LineConfig-AnnexbAnfpEnabledread-writemandatoryTRUE if Annex B ANFP functionality is enabled, otherwise FALSE. The gshdsl-standard-network-type must be set to European Annex B, and the port cannot be CPE. T…
1.3.6.1.4.1.529.23.14.2Tablemibhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfilesTablenot-accessiblemandatoryA list of mibhdsl2NetworkProfile__thresh_profiles__unit_thresh_profiles profile entries.
1.3.6.1.4.1.529.23.14.2.1Rowmibhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfilesEntrynot-accessiblemandatoryA mibhdsl2NetworkProfile__thresh_profiles__unit_thresh_profiles entry containing objects that maps to the parameters of mibhdsl2NetworkProfile__thresh_profiles…
1.3.6.1.4.1.529.23.14.2.1.1Columnhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Shelf-oread-onlymandatory
1.3.6.1.4.1.529.23.14.2.1.2Columnhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Slot-oread-onlymandatory
1.3.6.1.4.1.529.23.14.2.1.3Columnhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Item-oread-onlymandatory
1.3.6.1.4.1.529.23.14.2.1.4Columnhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Index-oread-onlymandatory
1.3.6.1.4.1.529.23.14.2.1.5Columnhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-XruNetThreshProfileread-writemandatoryThe name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the network side of regenerator unit 1.
1.3.6.1.4.1.529.23.14.2.1.6Columnhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-XruCustThreshProfileread-writemandatoryThe name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the customer side of regenerator unit 1.
Type Definitions
NameSyntaxStatusDescription
DisplayStringOCTET STRING