ASCEND-MIBHDSL2NET-MIB
50 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.529.23.14 | Nodemibhdsl2NetworkProfile | |||
| 1.3.6.1.4.1.529.23.14.1 | Tablemibhdsl2NetworkProfileTable | not-accessible | mandatory | A list of mibhdsl2NetworkProfile profile entries. |
| 1.3.6.1.4.1.529.23.14.1.1 | Rowmibhdsl2NetworkProfileEntry | not-accessible | mandatory | A mibhdsl2NetworkProfile entry containing objects that maps to the parameters of mibhdsl2NetworkProfile profile. |
| 1.3.6.1.4.1.529.23.14.1.1.1 | Columnhdsl2NetworkProfile-Shelf-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.14.1.1.2 | Columnhdsl2NetworkProfile-Slot-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.14.1.1.3 | Columnhdsl2NetworkProfile-Item-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.14.1.1.4 | Columnhdsl2NetworkProfile-Name | read-write | mandatory | For future use. The current design does not use the name field but instead references Hdsl2 lines by the physical address; we may in the future support referen… |
| 1.3.6.1.4.1.529.23.14.1.1.5 | Columnhdsl2NetworkProfile-PhysicalAddress-Shelf | read-write | mandatory | The number of the shelf that the addressed physical device resides on. |
| 1.3.6.1.4.1.529.23.14.1.1.6 | Columnhdsl2NetworkProfile-PhysicalAddress-Slot | read-write | mandatory | The number of the slot that the addressed physical device resides on. |
| 1.3.6.1.4.1.529.23.14.1.1.7 | Columnhdsl2NetworkProfile-PhysicalAddress-ItemNumber | read-write | mandatory | A number that specifies an addressable entity within the context of shelf and slot. |
| 1.3.6.1.4.1.529.23.14.1.1.8 | Columnhdsl2NetworkProfile-Enabled | read-write | mandatory | TRUE if the line is enabled, otherwise FALSE. |
| 1.3.6.1.4.1.529.23.14.1.1.9 | Columnhdsl2NetworkProfile-ProfileNumber | read-write | mandatory | For potential backwards compatibility. The current design consists of one line profile numbered 0. |
| 1.3.6.1.4.1.529.23.14.1.1.10 | Columnhdsl2NetworkProfile-LineConfig-TrunkGroup | read-write | mandatory | The trunk group to which this line is assigned. 0 means this line is not part of a trunk group. |
| 1.3.6.1.4.1.529.23.14.1.1.11 | Columnhdsl2NetworkProfile-LineConfig-NailedGroup | read-write | mandatory | A number that identifies the set of lines that makes up a nailed group. 0 means this line is not part of a nailed group. |
| 1.3.6.1.4.1.529.23.14.1.1.12 | Columnhdsl2NetworkProfile-LineConfig-VpSwitchingVpi | read-write | mandatory | The Vpi to be used for the VP switching. Rest of the valid VPIs in valid vpi-vci-range will be used for the VC switching. Changes in this range will take effec… |
| 1.3.6.1.4.1.529.23.14.1.1.13 | Columnhdsl2NetworkProfile-LineConfig-RoutePort-SlotNumber-SlotNumber | read-write | mandatory | |
| 1.3.6.1.4.1.529.23.14.1.1.14 | Columnhdsl2NetworkProfile-LineConfig-RoutePort-SlotNumber-ShelfNumber | read-write | mandatory | TNT is a multi shelf system. To minimise the changes required to existing code the shelf number is added to this structure as it will almost always be needed w… |
| 1.3.6.1.4.1.529.23.14.1.1.15 | Columnhdsl2NetworkProfile-LineConfig-RoutePort-RelativePortNumber-RelativePortNumber | read-write | mandatory | |
| 1.3.6.1.4.1.529.23.14.1.1.16 | Columnhdsl2NetworkProfile-LineConfig-Activation | read-write | mandatory | Line activation mode. |
| 1.3.6.1.4.1.529.23.14.1.1.17 | Columnhdsl2NetworkProfile-LineConfig-CallRouteInfo-Shelf | read-write | mandatory | The number of the shelf that the addressed physical device resides on. |
| 1.3.6.1.4.1.529.23.14.1.1.18 | Columnhdsl2NetworkProfile-LineConfig-CallRouteInfo-Slot | read-write | mandatory | The number of the slot that the addressed physical device resides on. |
| 1.3.6.1.4.1.529.23.14.1.1.19 | Columnhdsl2NetworkProfile-LineConfig-CallRouteInfo-ItemNumber | read-write | mandatory | A number that specifies an addressable entity within the context of shelf and slot. |
| 1.3.6.1.4.1.529.23.14.1.1.20 | Columnhdsl2NetworkProfile-LineConfig-UnitType | read-write | mandatory | The Unit Type defines if a line is acting as either a Central Office (COE) or Customer Premise Equipment (CPE). Note that the remote unit needs to be configure… |
| 1.3.6.1.4.1.529.23.14.1.1.23 | Columnhdsl2NetworkProfile-Action-o | read-write | mandatory | |
| 1.3.6.1.4.1.529.23.14.1.1.24 | Columnhdsl2NetworkProfile-SparingMode | read-write | mandatory | Port sparing operational mode for this port. |
| 1.3.6.1.4.1.529.23.14.1.1.25 | Columnhdsl2NetworkProfile-LineConfig-NtrEnabled | read-write | mandatory | TRUE if NTR functionality is enabled, otherwise FALSE. If the unit-type is COE, it will take the system clock as the input when NTR is enabled and allow the re… |
| 1.3.6.1.4.1.529.23.14.1.1.26 | Columnhdsl2NetworkProfile-LineConfig-ClockSource | read-write | mandatory | Determine whether the 8KHz clock from the HDSL2 line (unit-type has to be CPE and ntr-enabled has to be yes) is eligible to be used as the 8KHz system clock so… |
| 1.3.6.1.4.1.529.23.14.1.1.27 | Columnhdsl2NetworkProfile-LineConfig-ClockPriority | read-write | mandatory | Clock priority assigned to the HDSL2 line. Used to select a particular HDSL2 line as the 8KHz system clock source. |
| 1.3.6.1.4.1.529.23.14.1.1.28 | Columnhdsl2NetworkProfile-LineConfig-LoopBack | read-write | mandatory | Configuration of different modem loopbacks. |
| 1.3.6.1.4.1.529.23.14.1.1.29 | Columnhdsl2NetworkProfile-IgnoreLineup | read-write | mandatory | Ignore line up value for this port. |
| 1.3.6.1.4.1.529.23.14.1.1.30 | Columnhdsl2NetworkProfile-LineConfig-Margin | read-write | mandatory | Selects a margin range between the signal to noise floor. |
| 1.3.6.1.4.1.529.23.14.1.1.31 | Columnhdsl2NetworkProfile-LineConfig-RateMode | read-write | mandatory | Used for G.SHDSL technology. Selects if the modem operates in Fixed or Auto rate mode. |
| 1.3.6.1.4.1.529.23.14.1.1.32 | Columnhdsl2NetworkProfile-LineConfig-MinRate | read-write | mandatory | Used for G.SHDSL technology. When the rate-mode is set to Auto, this is the minimum rate the modem will train to. |
| 1.3.6.1.4.1.529.23.14.1.1.33 | Columnhdsl2NetworkProfile-LineConfig-MaxRate | read-write | mandatory | Used for G.SHDSL technology. When the rate-mode is set to Auto, this is the maximum rate the modem will train to. When the rate-mode is set to Fixed, this is t… |
| 1.3.6.1.4.1.529.23.14.1.1.34 | Columnhdsl2NetworkProfile-LineConfig-GshdslStandardNetworkType | read-write | mandatory | Per the G.SHDSL Standard G.991.2. This parameter allows selection for the modem to operate either the North American Annex 'A' or European Annex 'B' standard n… |
| 1.3.6.1.4.1.529.23.14.1.1.35 | Columnhdsl2NetworkProfile-LineConfig-GshdslPsdType | read-write | mandatory | Per the G.SHDSL Standard G.911.2. This parameter allows selection for the modem to output a symmetric PSD at all rates or asymmetric PSD's at fixed rates of 77… |
| 1.3.6.1.4.1.529.23.14.1.1.36 | Columnhdsl2NetworkProfile-ThreshProfiles-SpanThreshProfile | read-write | mandatory | The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for all the HDSL2/SHDSL units for this port unles… |
| 1.3.6.1.4.1.529.23.14.1.1.37 | Columnhdsl2NetworkProfile-ThreshProfiles-XtucThreshProfile | read-write | mandatory | The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the DSLAM. |
| 1.3.6.1.4.1.529.23.14.1.1.38 | Columnhdsl2NetworkProfile-ThreshProfiles-XturThreshProfile | read-write | mandatory | The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the remote CPE. |
| 1.3.6.1.4.1.529.23.14.1.1.39 | Columnhdsl2NetworkProfile-LineConfig-SnextMargin | read-write | mandatory | Selects a Snext margin range with a worst-case self next noise model given current loop insertion loss. |
| 1.3.6.1.4.1.529.23.14.1.1.40 | Columnhdsl2NetworkProfile-LineConfig-AnnexbAnfpEnabled | read-write | mandatory | TRUE if Annex B ANFP functionality is enabled, otherwise FALSE. The gshdsl-standard-network-type must be set to European Annex B, and the port cannot be CPE. T… |
| 1.3.6.1.4.1.529.23.14.2 | Tablemibhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfilesTable | not-accessible | mandatory | A list of mibhdsl2NetworkProfile__thresh_profiles__unit_thresh_profiles profile entries. |
| 1.3.6.1.4.1.529.23.14.2.1 | Rowmibhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfilesEntry | not-accessible | mandatory | A mibhdsl2NetworkProfile__thresh_profiles__unit_thresh_profiles entry containing objects that maps to the parameters of mibhdsl2NetworkProfile__thresh_profiles… |
| 1.3.6.1.4.1.529.23.14.2.1.1 | Columnhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Shelf-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.14.2.1.2 | Columnhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Slot-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.14.2.1.3 | Columnhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Item-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.14.2.1.4 | Columnhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-Index-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.14.2.1.5 | Columnhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-XruNetThreshProfile | read-write | mandatory | The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the network side of regenerator unit 1. |
| 1.3.6.1.4.1.529.23.14.2.1.6 | Columnhdsl2NetworkProfile-ThreshProfiles-UnitThreshProfiles-XruCustThreshProfile | read-write | mandatory | The name consists of a null terminated ascii string supplied by the user. This profile defines the thresholds for the customer side of regenerator unit 1. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DisplayString | OCTET STRING |