MIB Viewer

ASCEND-MIBREDHM-MIB

18 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.529.23.179NodemibredHealthMonitoringProfile
1.3.6.1.4.1.529.23.179.1TablemibredHealthMonitoringProfileTablenot-accessiblemandatoryA list of mibredHealthMonitoringProfile profile entries.
1.3.6.1.4.1.529.23.179.1.1RowmibredHealthMonitoringProfileEntrynot-accessiblemandatoryA mibredHealthMonitoringProfile entry containing objects that maps to the parameters of mibredHealthMonitoringProfile profile.
1.3.6.1.4.1.529.23.179.1.1.1ColumnredHealthMonitoringProfile-Index-oread-onlymandatory
1.3.6.1.4.1.529.23.179.1.1.2ColumnredHealthMonitoringProfile-HmEnabledread-writemandatoryIndicates whether health monitoring feature is enabled. Redundancy feature has to be enabled prior to this feature
1.3.6.1.4.1.529.23.179.1.1.3ColumnredHealthMonitoringProfile-MaxWarningPrimaryread-writemandatoryMaximum of total warnings allowed for primary, When the total warnings exceeds this maximum, controller will reset.
1.3.6.1.4.1.529.23.179.1.1.4ColumnredHealthMonitoringProfile-MaxWarningSecondaryread-writemandatoryMaximum of total warnings allowed for secondary, When the total warnings exceeds this maximum, controller will reset. Secondary should have a more stringent va…
1.3.6.1.4.1.529.23.179.1.1.5ColumnredHealthMonitoringProfile-MaxWarningPerMinutePrimaryread-writemandatoryMaximum of total warning per minute allowed for primary.
1.3.6.1.4.1.529.23.179.1.1.6ColumnredHealthMonitoringProfile-MaxWarningPerMinuteSecondaryread-writemandatoryMaximum of total warning per minute allowed for secondary. Secondary should have a more stringent value than primary.
1.3.6.1.4.1.529.23.179.1.1.7ColumnredHealthMonitoringProfile-MemoryThresholdPrimaryread-writemandatoryPercent threshold for available memory on primary, controller resets when memory is lower than the threshold.
1.3.6.1.4.1.529.23.179.1.1.8ColumnredHealthMonitoringProfile-MemoryThresholdSecondaryread-writemandatoryPercent threshold for available memory on secondary, controller resets when memory is lower than the threshold. Secondary should have a more stringent value th…
1.3.6.1.4.1.529.23.179.1.1.9ColumnredHealthMonitoringProfile-MemoryAlertThresholdPrimaryread-writemandatoryPercent threshold for memory alert polling on primary, when memory level is lower than the threshold, log message will be sent out.
1.3.6.1.4.1.529.23.179.1.1.10ColumnredHealthMonitoringProfile-MemoryAlertThresholdSecondaryread-writemandatoryPercent threshold for memory alert polling on secondary, when memory level is lower than the threshold, log message will be sent out.
1.3.6.1.4.1.529.23.179.1.1.11ColumnredHealthMonitoringProfile-MemoryAlertTimeoutPrimaryread-writemandatoryMaximum time (in sec) allowed for memory level stays continuously below memory-alert-threshold-primary.
1.3.6.1.4.1.529.23.179.1.1.12ColumnredHealthMonitoringProfile-MemoryAlertTimeoutSecondaryread-writemandatoryMaximum time (in sec) allowed for memory level stays continuously below memory-alert-threshold-secondary.
1.3.6.1.4.1.529.23.179.1.1.13ColumnredHealthMonitoringProfile-ResetStuckPrimaryTimeoutread-writemandatorysecondary resets primary if no response from primary exceeds this timeout (in seconds). Minimum is 3 seconds.
1.3.6.1.4.1.529.23.179.1.1.14ColumnredHealthMonitoringProfile-Action-oread-writemandatory
Type Definitions
NameSyntaxStatusDescription
DisplayStringOCTET STRING