ASCEND-MIBSTATICHSSLOT-MIB
17 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.529.23.32 | NodemibmibProfHighSpeedSlotStatic | |||
| 1.3.6.1.4.1.529.23.32.1 | TablemibmibProfHighSpeedSlotStaticTable | not-accessible | mandatory | A list of mibmibProfHighSpeedSlotStatic profile entries. |
| 1.3.6.1.4.1.529.23.32.1.1 | RowmibmibProfHighSpeedSlotStaticEntry | not-accessible | mandatory | A mibmibProfHighSpeedSlotStatic entry containing objects that maps to the parameters of mibmibProfHighSpeedSlotStatic profile. |
| 1.3.6.1.4.1.529.23.32.1.1.1 | ColumnmibProfHighSpeedSlotStatic-Shelf-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.32.1.1.2 | ColumnmibProfHighSpeedSlotStatic-Slot-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.32.1.1.3 | ColumnmibProfHighSpeedSlotStatic-Item-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.32.1.1.4 | ColumnmibProfHighSpeedSlotStatic-Name | read-write | mandatory | For future use. The current design does not use this name attribute but instead references a LIM or CM slot by its profile index; we may in the future support … |
| 1.3.6.1.4.1.529.23.32.1.1.5 | ColumnmibProfHighSpeedSlotStatic-PhysicalAddress-Shelf | read-write | mandatory | The number of the shelf that the addressed physical device resides on. |
| 1.3.6.1.4.1.529.23.32.1.1.6 | ColumnmibProfHighSpeedSlotStatic-PhysicalAddress-Slot | read-write | mandatory | The number of the slot that the addressed physical device resides on. |
| 1.3.6.1.4.1.529.23.32.1.1.7 | ColumnmibProfHighSpeedSlotStatic-PhysicalAddress-ItemNumber | read-write | mandatory | A number that specifies an addressable entity within the context of shelf and slot. |
| 1.3.6.1.4.1.529.23.32.1.1.8 | ColumnmibProfHighSpeedSlotStatic-AtmParameters-IncomingPriority | read-write | mandatory | Specifies the relative priority of ATM cells incoming from this LIM or CM slot. A slot's incoming-priority is used to select the appropriate outgoing queue tha… |
| 1.3.6.1.4.1.529.23.32.1.1.9 | ColumnmibProfHighSpeedSlotStatic-Action-o | read-write | mandatory | |
| 1.3.6.1.4.1.529.23.32.1.1.10 | ColumnmibProfHighSpeedSlotStatic-TrunkCacConfig-Enable | read-write | mandatory | Enable or Disable CAC on this port. yes: CAC is enable on this port. no: CAC is disable on this port |
| 1.3.6.1.4.1.529.23.32.1.1.11 | ColumnmibProfHighSpeedSlotStatic-TrunkCacConfig-PortNum | read-only | mandatory | Identifies this trunk port within the system. It is a read only field. |
| 1.3.6.1.4.1.529.23.32.1.1.12 | ColumnmibProfHighSpeedSlotStatic-TrunkCacConfig-LineRate | read-only | mandatory | Line rate of the trunk port in Kbits/sec. The trunk port can have real-time (guaranteed) traffic bandwidth up to this limit. In case of over subscription, ther… |
| 1.3.6.1.4.1.529.23.32.1.1.13 | ColumnmibProfHighSpeedSlotStatic-TrunkCacConfig-OverSubscription | read-write | mandatory | Allowed to specify over subscription to the line rate to a factor of over-subscription/10. e.g Allowed BW = (over-subscription * line-rate) /10 |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DisplayString | OCTET STRING |