ASCEND-MIBTHERMAL-MIB
15 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.529.23.129 | NodemibthermalProfile | |||
| 1.3.6.1.4.1.529.23.129.1 | TablemibthermalProfileTable | not-accessible | mandatory | A list of mibthermalProfile profile entries. |
| 1.3.6.1.4.1.529.23.129.1.1 | RowmibthermalProfileEntry | not-accessible | mandatory | A mibthermalProfile entry containing objects that maps to the parameters of mibthermalProfile profile. |
| 1.3.6.1.4.1.529.23.129.1.1.1 | ColumnthermalProfile-Index-o | read-only | mandatory | |
| 1.3.6.1.4.1.529.23.129.1.1.2 | ColumnthermalProfile-FantrayLownoiseRpm | read-write | mandatory | RPM of the fantray in Low-Noise mode |
| 1.3.6.1.4.1.529.23.129.1.1.3 | ColumnthermalProfile-OperationMode | read-write | mandatory | Operation mode of the fantray |
| 1.3.6.1.4.1.529.23.129.1.1.4 | ColumnthermalProfile-LowTemperatureThreshold | read-write | mandatory | Low shelf-controller temperature trigger level (in Celsius). When operation-mode = auto-regulation and the temperature falls below this value, the fans return … |
| 1.3.6.1.4.1.529.23.129.1.1.5 | ColumnthermalProfile-HighTemperatureThreshold | read-write | mandatory | High shelf-controller temperature trigger level (in Celsius). When operation-mode = auto-regulation and this temperature is exceeded, the fans switch to full s… |
| 1.3.6.1.4.1.529.23.129.1.1.6 | ColumnthermalProfile-AlarmTemperatureTrigger | read-write | mandatory | Temperature that if exceeded, will trigger an ALARM state (in Celsius) |
| 1.3.6.1.4.1.529.23.129.1.1.7 | ColumnthermalProfile-Action-o | read-write | mandatory | |
| 1.3.6.1.4.1.529.23.129.1.1.8 | ColumnthermalProfile-BottomLowTemperatureThreshold | read-write | mandatory | Bottom thermal sensor low temperature trigger level (in Celsius). When temperature falls below this value, trigger ALARM state |
| 1.3.6.1.4.1.529.23.129.1.1.9 | ColumnthermalProfile-BottomHighTemperatureThreshold | read-write | mandatory | Bottom thermal sensor high temperature trigger level (in Celsius). When this temperature is exceeded, trigger ALARM state |
| 1.3.6.1.4.1.529.23.129.1.1.10 | ColumnthermalProfile-TopLowTemperatureThreshold | read-write | mandatory | Top thermal sensor low temperature trigger level (in Celsius). When temperature falls below this value, trigger ALARM state |
| 1.3.6.1.4.1.529.23.129.1.1.11 | ColumnthermalProfile-TopHighTemperatureThreshold | read-write | mandatory | Top thermal sensor high temperature trigger level (in Celsius). When this temperature is exceeded, trigger ALARM state |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DisplayString | OCTET STRING |