MIB Viewer

ASETEK-RACKCDU-SMI-V1-MIB-V16

151 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.39829Nodeasetek
1.3.6.1.4.1.39829.1NoderackCDU
1.3.6.1.4.1.39829.1.0Nodetraps
1.3.6.1.4.1.39829.1.1Nodeproduct
1.3.6.1.4.1.39829.1.1.1Scalarnameread-writemandatoryProduct name.
1.3.6.1.4.1.39829.1.1.2Scalarversionread-onlymandatorySoftware version.
1.3.6.1.4.1.39829.1.1.3Scalardateread-onlymandatorySoftware revision date.
1.3.6.1.4.1.39829.1.1.4ScalarrackNumberread-writemandatoryRackCDU number.
1.3.6.1.4.1.39829.1.1.5Scalardescriptionread-writemandatoryRackCDU description.
1.3.6.1.4.1.39829.1.1.6Scalarstatusread-onlymandatoryThe overall status of the RackCDU. Status is evaluated based on the notification settings. If a noticiation has been disabled it will not be included in the ov…
1.3.6.1.4.1.39829.1.2Nodesetup
1.3.6.1.4.1.39829.1.2.1TablenotifyTablenot-accessiblemandatoryTable of settings used to setup notifications.
1.3.6.1.4.1.39829.1.2.1.1RownotifyEntrynot-accessiblemandatorySingle notify entry containing notification receiver info.
1.3.6.1.4.1.39829.1.2.1.1.1ColumnnotifyReceiverNumberread-onlymandatoryIndex of notification receiver.
1.3.6.1.4.1.39829.1.2.1.1.2ColumnnotifyEnabledread-writemandatoryIndicates if this notify entry is enabled or not.
1.3.6.1.4.1.39829.1.2.1.1.3ColumnnotifyReceiverIPAddressread-writemandatoryNotification receiver IP address.
1.3.6.1.4.1.39829.1.2.1.1.4ColumnnotifyCommunityread-writemandatoryNotification community to be used by agent to send trap.
1.3.6.1.4.1.39829.1.3Nodemeasurements
1.3.6.1.4.1.39829.1.3.100ScalartemperatureFacilityInread-onlymandatoryThe temperature of the water going into the RackCDU on the Facility side (cold).
1.3.6.1.4.1.39829.1.3.101ScalartemperatureFacilityOutread-onlymandatoryThe temperature of the water going out of the RackCDU on the Facility side (hot).
1.3.6.1.4.1.39829.1.3.102ScalartemperatureServerInread-onlymandatoryThe temperature of the water going into the servers node (cold).
1.3.6.1.4.1.39829.1.3.103ScalartemperatureServerOutread-onlymandatoryThe temperature of the water going out of the servers node (hot).
1.3.6.1.4.1.39829.1.3.104ScalartemperatureAmbientread-onlyobsoleteThe temperature of the ambient air close to the RackCDU.
1.3.6.1.4.1.39829.1.3.105ScalarpressureServerread-onlymandatoryThe pressure inside the RackCDU on the server side.
1.3.6.1.4.1.39829.1.3.106ScalarpressureFacilityread-onlymandatoryThe pressure inside the RackCDU on the facility side.
1.3.6.1.4.1.39829.1.3.107ScalarserverLeakread-onlymandatoryBoolean indication of whether the RackCDU has detected a leak in the system.
1.3.6.1.4.1.39829.1.3.108ScalarserverLevelread-onlymandatoryBoolean indication of whether the RackCDU has detected a low level of cooleant.
1.3.6.1.4.1.39829.1.3.109ScalarflowFacilityread-onlymandatoryThe flow of the cooleant on the facility side.
1.3.6.1.4.1.39829.1.3.110Scalarheatloadread-onlymandatoryThe heatload of the cooleant on the facility side. Can be averaged from e.g. 1 to 28800 (24 hours) sec.
1.3.6.1.4.1.39829.1.3.111ScalarcontrollerOutread-onlymandatoryThe controller output.
1.3.6.1.4.1.39829.1.4Nodenetwork
1.3.6.1.4.1.39829.1.4.91ScalaripStoreFlashread-writemandatorystore settings to Flash.
1.3.6.1.4.1.39829.1.4.92ScalarmodeOfOperationread-writemandatoryMode of operation of ControlBox, can be agent or master.
1.3.6.1.4.1.39829.1.4.93ScalaripAddrread-writemandatoryIP address of ControlBox.
1.3.6.1.4.1.39829.1.4.94ScalarpriDNSread-writemandatoryPrimary DNS address of ControlBox.
1.3.6.1.4.1.39829.1.4.95ScalarsecDNSread-writemandatorySecondary DNS address of ControlBox.
1.3.6.1.4.1.39829.1.4.96ScalarnetMaskread-writemandatoryNetmask of ControlBox.
1.3.6.1.4.1.39829.1.4.97Scalargatewayread-writemandatoryGateway of ControlBox.
1.3.6.1.4.1.39829.1.4.98ScalaripSrcread-writemandatoryIP address source of ControlBox, eg. static or dhcp.
1.3.6.1.4.1.39829.1.4.99ScalaripRebootread-writemandatoryIP address reboot.
1.3.6.1.4.1.39829.1.5Nodecontroller
1.3.6.1.4.1.39829.1.5.80ScalargainProportionalread-writemandatoryProportional gain in PID controller.
1.3.6.1.4.1.39829.1.5.81ScalargainIntegralread-writemandatoryIntegral gain in PID controller.
1.3.6.1.4.1.39829.1.5.82ScalargainDifferentialread-writemandatoryDifferential gain in PID controller.
1.3.6.1.4.1.39829.1.5.83ScalardeltaOutMaxread-writemandatoryMaximum delta output from controller.
1.3.6.1.4.1.39829.1.5.84ScalarlimitPwmMaxread-writemandatoryMaximum PWM output.
1.3.6.1.4.1.39829.1.5.85ScalarlimitPwmMinread-writemandatoryMinimum PWM output.
1.3.6.1.4.1.39829.1.5.86ScalarsetpointFacilityOutread-writemandatorySetpoint for Facility Out Temperature.
1.3.6.1.4.1.39829.1.5.87ScalarcontrollerOutAlpharead-writemandatoryController Out Alpha - damping factor of output.
1.3.6.1.4.1.39829.1.6Nodeunits
1.3.6.1.4.1.39829.1.6.70ScalarfluidHeatCapacityread-writemandatoryHeat Capacity of the liquid coolant utilized in the facility loop.
1.3.6.1.4.1.39829.1.6.71ScalarheatAverageFactorread-writemandatoryThe time frame of which the heat load is averaged. A short time frame make the heat load sensative to small changes is temperature and flow which results in a …
1.3.6.1.4.1.39829.1.6.72ScalarharnessVersionread-writemandatoryMust be set to the harness version utilized by the RackCDU. The harness version may affect the functionality of the RackCDU and it it therefor important that t…
1.3.6.1.4.1.39829.1.7Nodenotifications
1.3.6.1.4.1.39829.1.7.150ScalarsnmpTrapsAlarmEnableread-writemandatoryEnable SNMP Alarm traps.
1.3.6.1.4.1.39829.1.7.151ScalarsnmpTrapsWarningEnableread-writemandatoryEnable SNMP Warning traps.
1.3.6.1.4.1.39829.1.7.152ScalarsmtpTrapsAlarmEnableread-writemandatoryEnable SMTP Alarm traps.
1.3.6.1.4.1.39829.1.7.153ScalarsmtpTrapsWarningEnableread-writemandatoryEnable SMTP Warning traps.
1.3.6.1.4.1.39829.1.7.154ScalarwarningMinFiread-writemandatorySet Facility In Min Warning level.
1.3.6.1.4.1.39829.1.7.155ScalarwarningMinEnableFiread-writemandatoryEnable Facility In Min Warning level.
1.3.6.1.4.1.39829.1.7.156ScalarwarningMaxFiread-writemandatorySet Facility In Max Warning level.
1.3.6.1.4.1.39829.1.7.157ScalarwarningMaxEnableFiread-writemandatoryEnable Facility In Max Warning level.
1.3.6.1.4.1.39829.1.7.158ScalaralarmMinFiread-writemandatorySet Facility In Min Alarm level.
1.3.6.1.4.1.39829.1.7.159ScalaralarmMinEnableFiread-writemandatoryEnable Facility In Min Alarm level.
1.3.6.1.4.1.39829.1.7.160ScalaralarmMaxFiread-writemandatorySet Facility In Max Alarm level.
1.3.6.1.4.1.39829.1.7.161ScalaralarmMaxEnableFiread-writemandatoryEnable Facility In Max Alarm level.
1.3.6.1.4.1.39829.1.7.162ScalarwarningMinForead-writemandatorySet Facility Out Min Warning level.
1.3.6.1.4.1.39829.1.7.163ScalarwarningMinEnableForead-writemandatoryEnable Facility Out Min Warning level.
1.3.6.1.4.1.39829.1.7.164ScalarwarningMaxForead-writemandatorySet Facility Out Max Warning level.
1.3.6.1.4.1.39829.1.7.165ScalarwarningMaxEnableForead-writemandatoryEnable Facility Out Max Warning level.
1.3.6.1.4.1.39829.1.7.166ScalaralarmMinForead-writemandatorySet Facility Out Min alarm level.
1.3.6.1.4.1.39829.1.7.167ScalaralarmMinEnableForead-writemandatoryEnable Facility Out Min alarm level.
1.3.6.1.4.1.39829.1.7.168ScalaralarmMaxForead-writemandatorySet Facility Out Max Alarm level.
1.3.6.1.4.1.39829.1.7.169ScalaralarmMaxEnableForead-writemandatoryEnable Facility Out Max Alarm level.
1.3.6.1.4.1.39829.1.7.170ScalarwarningMinSiread-writemandatorySet Server In Min Warning level.
1.3.6.1.4.1.39829.1.7.171ScalarwarningMinEnableSiread-writemandatoryEnable Server In Min Warning level.
1.3.6.1.4.1.39829.1.7.172ScalarwarningMaxSiread-writemandatorySet Server In Max Warning level.
1.3.6.1.4.1.39829.1.7.173ScalarwarningMaxEnableSiread-writemandatoryEnable Server In Max Warning level.
1.3.6.1.4.1.39829.1.7.174ScalaralarmMinSiread-writemandatorySet Server In Min Alarm level.
1.3.6.1.4.1.39829.1.7.175ScalaralarmMinEnableSiread-writemandatoryEnable Server In Min Alarm level.
1.3.6.1.4.1.39829.1.7.176ScalaralarmMaxSiread-writemandatorySet Server In Max Alarm level.
1.3.6.1.4.1.39829.1.7.177ScalaralarmMaxEnableSiread-writemandatoryEnable Server In Max Alarm level.
1.3.6.1.4.1.39829.1.7.178ScalarwarningMinSoread-writemandatorySet Server Out Min Warning level.
1.3.6.1.4.1.39829.1.7.179ScalarwarningMinEnableSoread-writemandatoryEnable Server Out Min Warning level.
1.3.6.1.4.1.39829.1.7.180ScalarwarningMaxSoread-writemandatorySet Server Out Max Warning level.
1.3.6.1.4.1.39829.1.7.181ScalarwarningMaxEnableSoread-writemandatoryEnable Server Out Max Warning level.
1.3.6.1.4.1.39829.1.7.182ScalaralarmMinSoread-writemandatorySet Server Out Min Alarm level.
1.3.6.1.4.1.39829.1.7.183ScalaralarmMinEnableSoread-writemandatoryEnable Server Out Min Alarm level.
1.3.6.1.4.1.39829.1.7.184ScalaralarmMaxSoread-writemandatorySet Server Out Max Alarm level.
1.3.6.1.4.1.39829.1.7.185ScalaralarmMaxEnableSoread-writemandatoryEnable Server Out Max Alarm level.
1.3.6.1.4.1.39829.1.7.186ScalarwarningMinFlowread-writemandatorySet Flow Min Warning level.
1.3.6.1.4.1.39829.1.7.187ScalarwarningMinEnableFlowread-writemandatoryEnable Flow Min Warning level.
1.3.6.1.4.1.39829.1.7.188ScalarwarningMaxFlowread-writemandatorySet Flow Max Warning level.
1.3.6.1.4.1.39829.1.7.189ScalarwarningMaxEnableFlowread-writemandatoryEnable Flow Max Warning level.
1.3.6.1.4.1.39829.1.7.190ScalaralarmMinFlowread-writemandatorySet Flow Min Alarm level.
1.3.6.1.4.1.39829.1.7.191ScalaralarmMinEnableFlowread-writemandatoryEnable Flow Min Alarm level.
1.3.6.1.4.1.39829.1.7.192ScalaralarmMaxFlowread-writemandatorySet Flow Max Alarm level.
1.3.6.1.4.1.39829.1.7.193ScalaralarmMaxEnableFlowread-writemandatoryEnable Flow Max Alarm level.
1.3.6.1.4.1.39829.1.7.194ScalarwarningMinPressureServerread-writemandatorySet Server Pressure Min Warning level.
1.3.6.1.4.1.39829.1.7.195ScalarwarningMinEnablePressureServerread-writemandatoryEnable Server Pressure Min Warning level.
1.3.6.1.4.1.39829.1.7.196ScalarwarningMaxPressureServerread-writemandatorySet Server Pressure Max Warning level.
1.3.6.1.4.1.39829.1.7.197ScalarwarningMaxEnablePressureServerread-writemandatoryEnable Server Pressure Max Warning level.
1.3.6.1.4.1.39829.1.7.198ScalaralarmMinPressureServerread-writemandatorySet Server Pressure Min Alarm level.
1.3.6.1.4.1.39829.1.7.199ScalaralarmMinEnablePressureServerread-writemandatoryEnable Server Pressure Min Alarm level.
1.3.6.1.4.1.39829.1.7.200ScalaralarmMaxPressureServerread-writemandatorySet Server Pressure Max Alarm level.
1.3.6.1.4.1.39829.1.7.201ScalaralarmMaxEnablePressureServerread-writemandatoryEnable Server Pressure Max Alarm level.
1.3.6.1.4.1.39829.1.7.202ScalarwarningMinPressureFacilityread-writemandatorySet Facility Pressure Min Warning level.
1.3.6.1.4.1.39829.1.7.203ScalarwarningMinEnablePressureFacilityread-writemandatoryEnable Facility Pressure Min Warning level.
1.3.6.1.4.1.39829.1.7.204ScalarwarningMaxPressureFacilityread-writemandatorySet Facility Pressure Max Warning level.
1.3.6.1.4.1.39829.1.7.205ScalarwarningMaxEnablePressureFacilityread-writemandatoryEnable Facility Pressure Max Warning level.
1.3.6.1.4.1.39829.1.7.206ScalaralarmMinPressureFacilityread-writemandatorySet Facility Pressure Min Alarm level.
1.3.6.1.4.1.39829.1.7.207ScalaralarmMinEnablePressureFacilityread-writemandatoryEnable Facility Pressure Min Alarm level.
1.3.6.1.4.1.39829.1.7.208ScalaralarmMaxPressureFacilityread-writemandatorySet Facility Pressure Max Alarm level.
1.3.6.1.4.1.39829.1.7.209ScalaralarmMaxEnablePressureFacilityread-writemandatoryEnable Facility Pressure Max Alarm level.
1.3.6.1.4.1.39829.1.7.210ScalaralarmEnableLeakread-writemandatoryEnable leak detection.
1.3.6.1.4.1.39829.1.7.211ScalaralarmEnableLevelread-writemandatoryEnable low liquid level.
1.3.6.1.4.1.39829.1.8Nodeconformance
1.3.6.1.4.1.39829.1.8.1NodecduProdGroup
1.3.6.1.4.1.39829.1.8.2NodecduSetupGroup
1.3.6.1.4.1.39829.1.8.3NodecduMeasGroup
1.3.6.1.4.1.39829.1.8.4NodecduMeasGroupRev2
1.3.6.1.4.1.39829.1.8.5NodecduNetGroup
1.3.6.1.4.1.39829.1.8.6NodecduCntlGroup
1.3.6.1.4.1.39829.1.8.7NodecduUnitGroup
1.3.6.1.4.1.39829.1.8.8NodecduNotifyGroup
1.3.6.1.4.1.39829.1.8.9NodecduTrapGroup
1.3.6.1.4.1.39829.1.8.10NodecduCompliances
1.3.6.1.4.1.39829.1.8.11NodecduEventGroup
1.3.6.1.4.1.39829.1.8.12NodecduTrapGroupRev2
1.3.6.1.4.1.39829.1.8.13NodecduCompliancesRev2
1.3.6.1.4.1.39829.1.9NodeeventDescriptors
1.3.6.1.4.1.39829.1.9.1ScalareventDescriptionread-onlymandatoryText which provide the user with a corrective action in case of a warning or alarm trap. IMPORTANT: Must only be used in traps! Any other use of this object is…
1.3.6.1.4.1.39829.1.9.2ScalareventValueread-onlymandatoryEvent value placeholder sent with generic traps where the unit of the value can be different. IMPORTANT: Must only be used in traps! Any other use of this obje…
1.3.6.1.4.1.39829.1.500NodealarmNotifyTrap alarm notification information for the SNMP Manager (obsolete).
1.3.6.1.4.1.39829.1.501NodewarningNotifyTrap warning notification information for the SNMP Manager (obsolete).
1.3.6.1.4.1.39829.1.504NodefacilitySupplyWarningFacility supply temperature warning.
1.3.6.1.4.1.39829.1.505NodefacilityReturnWarningFacility return temperature warning.
1.3.6.1.4.1.39829.1.506NodeserverSupplyWarningServer supply temperature warning.
1.3.6.1.4.1.39829.1.507NodeserverReturnWarningServer return temperature warning.
1.3.6.1.4.1.39829.1.508NodefacilityPressureWarningFacility pressure warning.
1.3.6.1.4.1.39829.1.509NodeserverPressureWarningServer pressure warning.
1.3.6.1.4.1.39829.1.512NodefacilityFlowWarningFacility flow warning.
1.3.6.1.4.1.39829.1.517NodefacilitySupplyAlarmFacility supply temperature alarm.
1.3.6.1.4.1.39829.1.518NodefacilityReturnAlarmFacility return temperature alarm.
1.3.6.1.4.1.39829.1.519NodeserverSupplyAlarmServer supply temperature alarm.
1.3.6.1.4.1.39829.1.520NodeserverReturnAlarmServer return temperature alarm.
1.3.6.1.4.1.39829.1.521NodefacilityPressureAlarmFacility pressure alarm.
1.3.6.1.4.1.39829.1.522NodeserverPressureAlarmServer pressure alarm.
1.3.6.1.4.1.39829.1.523NodeleakDetectionAlarmLeak detection alarm.
1.3.6.1.4.1.39829.1.524NodeliquidLevelAlarmLow liquid level alarm.
1.3.6.1.4.1.39829.1.525NodefacilityFlowAlarmFacility flow alarm.