ATT-CNM-FRAME-RELAY-MIB
40 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.74 | Nodeatt-2 | |||
| 1.3.6.1.4.1.74.1 | Nodeatt-products | |||
| 1.3.6.1.4.1.74.1.9 | Nodeatt-cnmAgent | |||
| 1.3.6.1.4.1.74.2 | Nodeatt-mgmt | |||
| 1.3.6.1.4.1.74.2.15 | Nodeatt-cnm | |||
| 1.3.6.1.4.1.74.2.15.7 | Nodeatt-cnm-fr | |||
| 1.3.6.1.4.1.74.2.15.7.1 | TableattCNMfrConfigTable | not-accessible | mandatory | A list of entries containing configuration information for all Frame Relay interfaces managed by this system. |
| 1.3.6.1.4.1.74.2.15.7.1.1 | RowattCNMfrConfigEntry | not-accessible | mandatory | An entry containing configuration information for a particular Frame Relay interface. |
| 1.3.6.1.4.1.74.2.15.7.1.1.1 | ColumnattCNMfrConfigIndex | read-only | mandatory | A unique value for each Frame Relay interface. The interface identified by a particular value of this index is the same interface as identified by the same val… |
| 1.3.6.1.4.1.74.2.15.7.1.1.2 | ColumnattCNMfrMeasMaxIntervals | read-only | mandatory | This variable identifies the maximum number of measurement intervals supported for the measurements maintained by this Frame Relay interface in the attCNMfrMea… |
| 1.3.6.1.4.1.74.2.15.7.1.1.3 | ColumnattCNMfrMeasIntervalLen | read-only | mandatory | This variable identifies the number of seconds that make up one complete measurement interval for for the measurements maintained by this Frame Relay interface… |
| 1.3.6.1.4.1.74.2.15.7.1.1.4 | ColumnattCNMfrPVCMeasMaxIntervals | read-only | mandatory | This variable identifies the maximum number of measurement intervals supported for the measurements maintained by this Frame Relay interface in the attCNMfrPVC… |
| 1.3.6.1.4.1.74.2.15.7.1.1.5 | ColumnattCNMfrPVCMeasIntervalLen | read-only | mandatory | This variable identifies the number of seconds that make up one complete measurement interval for for the measurements maintained by this Frame Relay interface… |
| 1.3.6.1.4.1.74.2.15.7.2 | TableattCNMfrMeasTable | not-accessible | mandatory | A list of entries containing measurement counts, maintained during the specified measurement interval, for all Frame Relay interfaces managed by this system. |
| 1.3.6.1.4.1.74.2.15.7.2.1 | RowattCNMfrMeasEntry | not-accessible | mandatory | An entry containing measurement counts, maintained during the specified measurement interval, for a particular Frame Relay interface. |
| 1.3.6.1.4.1.74.2.15.7.2.1.1 | ColumnattCNMfrMeasIndex | read-only | mandatory | A unique value for each Frame Relay interface. The interface identified by a particular value of this index is the same interface as identified by the same val… |
| 1.3.6.1.4.1.74.2.15.7.2.1.2 | ColumnattCNMfrMeasInterval | read-only | mandatory | This variable identifies the measurement interval number for which measurement is provided. It is a number between 1 and XX, where 1 identifies the most recent… |
| 1.3.6.1.4.1.74.2.15.7.2.1.3 | ColumnattCNMfrMeasTimeStamp | read-only | mandatory | The time stamp corresponding to the end of the specified measurement interval, as measured in seconds from 00:00:00 UTC (Coordinated Universal Time) January 1,… |
| 1.3.6.1.4.1.74.2.15.7.2.1.4 | ColumnattCNMfrMeasLocalTime | read-only | mandatory | The time stamp corresponding to the end of the specified measurement interval. Any fraction is rounded up. It is given as a printable ASCII string showing the … |
| 1.3.6.1.4.1.74.2.15.7.2.1.5 | ColumnattCNMfrReceivedOctets | read-only | mandatory | The counter associated with the number of bytes received by this Frame Relay interface during the specified measurement interval. |
| 1.3.6.1.4.1.74.2.15.7.2.1.6 | ColumnattCNMfrSentOctets | read-only | mandatory | The counter associated with the number of bytes sent by this Frame Relay interface during the specified measurement interval. |
| 1.3.6.1.4.1.74.2.15.7.2.1.7 | ColumnattCNMfrReceivedFrames | read-only | mandatory | The counter associated with the number of frames received by this Frame Relay interface during the specified measurement interval. |
| 1.3.6.1.4.1.74.2.15.7.2.1.8 | ColumnattCNMfrSentFrames | read-only | mandatory | The counter associated with the number of frames received by this Frame Relay interface during the specified measurement interval. |
| 1.3.6.1.4.1.74.2.15.7.2.1.9 | ColumnattCNMfrBadFrames | read-only | mandatory | The counter associated with the number of frames received by this interface that are faulty. A bad frame could be a frame with a non-integral number of octets,… |
| 1.3.6.1.4.1.74.2.15.7.2.1.10 | ColumnattCNMfrReceiverOverruns | read-only | mandatory | The counter associated with the number of receiver overruns occurred at this interface during the specified measurement interval. A receiver overrun occurs whe… |
| 1.3.6.1.4.1.74.2.15.7.3 | TableattCNMfrPVCMeasTable | not-accessible | mandatory | A list of entries containing PVC-level measurement counts, maintained during the specified measurement interval, for all the Frame Relay interfaces managed by … |
| 1.3.6.1.4.1.74.2.15.7.3.1 | RowattCNMfrPVCMeasEntry | not-accessible | mandatory | An entry containing measurement counts, maintained during the specified measurement interval, for a particular PVC on a specific Frame Relay interface. |
| 1.3.6.1.4.1.74.2.15.7.3.1.1 | ColumnattCNMfrPVCMeasIfIndex | read-only | mandatory | A unique value for each Frame Relay interface. The interface identified by a particular value of this index is the same interface as identified by the same val… |
| 1.3.6.1.4.1.74.2.15.7.3.1.2 | ColumnattCNMfrPVCMeasIndex | read-only | mandatory | The DLCI number on a Frame Relay interface that identifies a unique Data Link Connection. |
| 1.3.6.1.4.1.74.2.15.7.3.1.3 | ColumnattCNMfrPVCMeasInterval | read-only | mandatory | This variable identifies the measurement interval number for which measurement is provided. It is a number between 1 and XX, where 1 identifies the most recent… |
| 1.3.6.1.4.1.74.2.15.7.3.1.4 | ColumnattCNMfrPVCMeasTimeStamp | read-only | mandatory | The time stamp corresponding to the end of the specified measurement interval, as measured in seconds from 00:00:00 UTC (Coordinated Universal Time) January 1,… |
| 1.3.6.1.4.1.74.2.15.7.3.1.5 | ColumnattCNMfrPVCMeasLocalTime | read-only | mandatory | The time stamp corresponding to the end of the specified measurement interval. Any fraction is rounded up. It is given as a printable ASCII string showing the … |
| 1.3.6.1.4.1.74.2.15.7.3.1.6 | ColumnattCNMfrCongestionAtIngress | read-only | mandatory | The counter associated with the number of times frames received by this PVC had to be discarded because buffers were unavailable or congestion control was bein… |
| 1.3.6.1.4.1.74.2.15.7.3.1.7 | ColumnattCNMfrCongestionAtEgress | read-only | mandatory | The counter associated with the number of times frames sent by this PVC had to be discarded because buffers were unavailable or congestion control was being en… |
| 1.3.6.1.4.1.74.2.15.7.4 | TableattCNMfrPVCStatusTable | not-accessible | mandatory | A list of entries containing status information about Data Link Connections on Frame Relay interfaces managed by this system. |
| 1.3.6.1.4.1.74.2.15.7.4.1 | RowattCNMfrPVCStatusEntry | not-accessible | mandatory | An entry containing status information about a particular Data Link Connection on a specific Frame Relay interface. |
| 1.3.6.1.4.1.74.2.15.7.4.1.1 | ColumnattCNMfrPVCStatusIfIndex | read-only | mandatory | A unique value for each Frame Relay interface. The interface identified by a particular value of this index is the same interface as identified by the same val… |
| 1.3.6.1.4.1.74.2.15.7.4.1.2 | ColumnattCNMfrPVCStatusIndex | read-only | mandatory | The DLCI number on a Frame Relay interface that identifies a unique Data Link Connection. |
| 1.3.6.1.4.1.74.2.15.7.4.1.3 | ColumnattCNMfrPVCAdminStatus | read-only | mandatory | The desired state of this Data Link Connection. |
| 1.3.6.1.4.1.74.2.15.7.4.1.4 | ColumnattCNMfrPVCOperStatus | read-only | mandatory | The current operational state of this Data Link Connection. |