1.3.6.1.4.1.22638.6.3.2IdentityautomationSystemMIBDefinition of generic management objects which describe a general I IA product.
1.3.6.1.4.1.22638.6.3.2.1NodeautomationSystemObjects
1.3.6.1.4.1.22638.6.3.2.1.1NodeautomationSystemIdent
1.3.6.1.4.1.22638.6.3.2.1.1.1ScalarautomationManufacturerIdread-onlycurrentA code which identifies the vendor of the component (e. g. the specific department or OEM).
1.3.6.1.4.1.22638.6.3.2.1.1.2ScalarautomationOrderNumberread-onlycurrentThe type / order number of the system.
1.3.6.1.4.1.22638.6.3.2.1.1.3ScalarautomationSerialNumberread-onlycurrentThe serial number of the system.
1.3.6.1.4.1.22638.6.3.2.1.1.4ScalarautomationHwRevisionread-onlycurrentThe hardware version of the system.
1.3.6.1.4.1.22638.6.3.2.1.1.5ScalarautomationSwRevisionread-onlycurrentThe firmware version of the system.
1.3.6.1.4.1.22638.6.3.2.1.1.6ScalarautomationRevisionCounterread-onlycurrentThis value will be incremented every time one of the other values of automationIM0Group or automationIM1Group (cp. conformance statements) changes. The counter…
1.3.6.1.4.1.22638.6.3.2.1.1.7ScalarautomationRevisionDateread-onlycurrentThe time of the last change of the value of automationRevisionCounter. The value starts with the date of the default configuration. If a system doesn't support…
1.3.6.1.4.1.22638.6.3.2.1.1.8ScalarautomationFunctionTagread-onlycurrentA code which describes the function of the component within the plant. This value will be set by the engineering system. It is comparable to the 'sysName'of MI…
1.3.6.1.4.1.22638.6.3.2.1.1.9ScalarautomationLocationTagread-onlycurrentA code which describes the location where the component is installed within the plant. This value will be set by the engineering system. It is comparable to th…
1.3.6.1.4.1.22638.6.3.2.1.1.10ScalarautomationGeoLatituderead-writecurrentgeographical latitude of the equipment site shown in one of the following formats: - DD.DDDDDD^ - DD^MM.MMMM' - DD^MM'SS.SS. a leading '+' sign or the trailing…
1.3.6.1.4.1.22638.6.3.2.1.1.11ScalarautomationGeoLongituderead-writecurrentgeographical longitude of the equipment site shown in one of the following formats: - DDD.DDDDD^ - DDD^MM.MMMM' - DDD^MM'SS.SS a leading '+' sign or the traili…
1.3.6.1.4.1.22638.6.3.2.1.1.12ScalarautomationGeoHeightread-writecurrentgeographical height of the equipment site in the following format: - dddddd m (high-order zeros are suppressed) a leading sign '-' indicates a height below zer…
1.3.6.1.4.1.22638.6.3.2.1.1.13ScalarautomationTimeZoneOffsetHoursread-writecurrentThe offset hours of the time zone group's time zone from UTC.
1.3.6.1.4.1.22638.6.3.2.1.1.14ScalarautomationTimeZoneOffsetMinutesread-writecurrentThe offset minutes of the time zone group's time zone from UTC.
1.3.6.1.4.1.22638.6.3.2.1.1.15ScalarautomationSwUserread-onlycurrentThe name of the user who made the last firmware update. The value 'unknown' shall be given, if the user is not known.
1.3.6.1.4.1.22638.6.3.2.1.1.16ScalarautomationSwDateread-onlycurrentThe time of the last firmware update. The value starts with the date of the default configuration. If a system doesn't support an absolute time it must not sup…
1.3.6.1.4.1.22638.6.3.2.1.2NodeautomationSystemStatus
1.3.6.1.4.1.22638.6.3.2.1.2.1ScalarautomationOperStateread-onlycurrentGeneral operational status of the component. ok(0) indicates that the component works, no errors. maintenanceRequired(1) indicates, that at the moment there ar…
1.3.6.1.4.1.22638.6.3.2.1.2.2ScalarautomationApplicationOperStateread-onlycurrentOperating status of the application within the automation system. This status indicates whether the device context is part of an automation system that is in o…
1.3.6.1.4.1.22638.6.3.2.1.3NodeautomationSystemGeneric
1.3.6.1.4.1.22638.6.3.2.1.3.1ScalarautomationSystemRestartread-writecurrentRestart the system. Setting the value to 1 causes a coldstart, a value of 2 causes a warmstart. The different behaviour of coldstart and warmstart depends on t…
1.3.6.1.4.1.22638.6.3.2.1.3.3ScalarautomationPowerUpCountread-onlycurrentNumber of system starts.
1.3.6.1.4.1.22638.6.3.2.1.3.4ScalarautomationResetCountersread-writecurrentReset all statistic counters of the component. On write access only a value of set(1) will be accepted (and causes a reset of the counters of the system), all …
1.3.6.1.4.1.22638.6.3.2.1.3.5ScalarautomationConfigIdread-onlycurrentSignature of all configuration parameter values. The special value of all bytes 0x00 denotes the situation of a temporarily not available signature, what might…
1.3.6.1.4.1.22638.6.3.2.1.3.6ScalarautomationConfigUserread-onlycurrentThe name of the user who made the last change to any parameter of the configuration parameter set. The value 'unknown' shall be given, if the user is not known.
1.3.6.1.4.1.22638.6.3.2.1.3.7ScalarautomationConfigDateread-onlycurrentThe time of the last change to a parameter of the configuration parameter set. The value starts with the date of the default configuration. If a system doesn't…
1.3.6.1.4.1.22638.6.3.2.1.4NodeautomationSystemIp
1.3.6.1.4.1.22638.6.3.2.1.4.1ScalarautomationSystemIpAddressread-writedeprecatedThis object contains the IP address of the system (which is used to connect to the SNMP agent, the web entity etc.). If the component features an outbandport, …
1.3.6.1.4.1.22638.6.3.2.1.4.2ScalarautomationSystemIpSubnetMaskread-writedeprecatedThis object contains the subnet mask of the system (which is used to connect to the SNMP agent, the webentity etc.). If the component features an outbandport, …
1.3.6.1.4.1.22638.6.3.2.1.4.3ScalarautomationSystemIpGatewayread-writedeprecatedThe default gateway of the system.
1.3.6.1.4.1.22638.6.3.2.1.4.4ScalarautomationSystemOutbandIpread-writedeprecatedIf the system features an outband port, this object contains its IP address.
1.3.6.1.4.1.22638.6.3.2.1.4.5ScalarautomationSystemOutbandSubnetMaskread-writedeprecatedIf the system features an outband port, this object contains its subnet mask.
1.3.6.1.4.1.22638.6.3.2.2NodeautomationSystemNotifications
1.3.6.1.4.1.22638.6.3.2.2.0NodeautomationSystemNotificationsV2
1.3.6.1.4.1.22638.6.3.2.2.0.1NotificationautomationOperStateChangedcurrentThe system triggers this event in case the value of automationOperState changed.
1.3.6.1.4.1.22638.6.3.2.2.0.2NotificationautomationRevisionChangedcurrentThe system triggers this event in case the configuration changed (e. g. the hardware configuration, a firmware update or IP parameter).
1.3.6.1.4.1.22638.6.3.2.3NodeautomationSystemConformance
1.3.6.1.4.1.22638.6.3.2.3.1NodeautomationSystemGroups
1.3.6.1.4.1.22638.6.3.2.3.1.1GroupautomationIM0GroupcurrentThis group collects the named parameters according to the referenced guideline.
1.3.6.1.4.1.22638.6.3.2.3.1.2GroupautomationIM1GroupcurrentThis group collects the named parameters according to the referenced guideline.
1.3.6.1.4.1.22638.6.3.2.3.1.3GroupautomationIM2GroupcurrentThis group collects the named parameters according to the referenced guideline. The revision date is only available if the system supports an absolute time, th…
1.3.6.1.4.1.22638.6.3.2.3.1.4GroupautomationStatusGroupcurrentGeneric status information.
1.3.6.1.4.1.22638.6.3.2.3.1.5GroupautomationRemoteRestartGroupcurrentAllows restart via SNMP.
1.3.6.1.4.1.22638.6.3.2.3.1.6GroupautomationResetCounterGroupcurrentAllows reset of all counters.
1.3.6.1.4.1.22638.6.3.2.3.1.7GroupautomationIpGroupdeprecatedIP configuration of the agent.
1.3.6.1.4.1.22638.6.3.2.3.1.8GroupautomationOutbandGroupdeprecatedConfiguration of the outband port.
1.3.6.1.4.1.22638.6.3.2.3.1.9GroupautomationStatusEventscurrentNotifications about status changes.
1.3.6.1.4.1.22638.6.3.2.3.1.10GroupautomationConfigurationEventscurrentNotifications about configuration changes.
1.3.6.1.4.1.22638.6.3.2.3.1.11GroupautomationGeoLocationcurrentThis group collects the named parameters according to the geographical coordinates.
1.3.6.1.4.1.22638.6.3.2.3.1.12GroupautomationGeoLocationTimeShiftcurrentThis group collects the named parameters according to the geographical coordinates and the location dependent time shift.
1.3.6.1.4.1.22638.6.3.2.3.1.13GroupautomationConfigIdGroupcurrentThis group collects the named parameters for the suppport of a config signature.
1.3.6.1.4.1.22638.6.3.2.3.1.14GroupautomationSwDownloadGroupcurrentThis group collects the named parameters for a firmware download.
1.3.6.1.4.1.22638.6.3.2.3.2NodeautomationSystemCompliances
1.3.6.1.4.1.22638.6.3.2.3.2.1ComplianceautomationSystemBasicCompliancecurrentMinimum implementation requirements for all Industry Automation Division systems with SNMP support.
1.3.6.1.4.1.22638.6.3.2.3.2.2ComplianceautomationSystemExtCompliancedeprecatedExtended requirements for Industry Automation Division systems.
1.3.6.1.4.1.22638.6.3.2.3.2.3ComplianceautomationSystemExtCompliance2currentExtended requirements for Industry Automation Division systems.