MIB Viewer

AVICI-BAY-MIB

100 objects
The MIB module for an Avici Bay.
OIDNameAccessStatusDescription
1.3.6.1.4.1.2474.1.4IdentityaviciBayMIBThe MIB module for an Avici Bay.
1.3.6.1.4.1.2474.1.4.1NodeaviciBayObjects
1.3.6.1.4.1.2474.1.4.1.1TableaviciBayTablenot-accessiblecurrentThis table contains parameters and state variables for each Avici bay.
1.3.6.1.4.1.2474.1.4.1.1.1RowaviciBayEntrynot-accessiblecurrentAn entry containing management information for each bay.
1.3.6.1.4.1.2474.1.4.1.1.1.1ColumnaviciBayIndexread-onlycurrentThe index number of the bay entry.
1.3.6.1.4.1.2474.1.4.1.1.1.2ColumnaviciBayCriticalLedread-onlycurrentThe state of the Critical Led on the Bay.
1.3.6.1.4.1.2474.1.4.1.1.1.3ColumnaviciBayMajorLedread-onlycurrentThe state of the Major Led on the Bay.
1.3.6.1.4.1.2474.1.4.1.1.1.4ColumnaviciBayMinorLedread-onlycurrentThe state of the Minor Led on the Bay.
1.3.6.1.4.1.2474.1.4.1.1.1.5ColumnaviciBayAlarmCutOffread-onlycurrentCentral office alarms are triggered by a hardware condition. A write can only use the value off. This turns off the Central Office audible alarms.
1.3.6.1.4.1.2474.1.4.1.1.1.6ColumnaviciBayModTempCriticalThresholdread-onlycurrentThe module temperature in degrees C above which a critical alarm will be triggered.
1.3.6.1.4.1.2474.1.4.1.1.1.7ColumnaviciBayModTempMajorThresholdread-onlycurrentThe module temperature in degrees C above which a major alarm will be triggered.
1.3.6.1.4.1.2474.1.4.1.1.1.8ColumnaviciBayModTempMinorThresholdread-onlycurrentThe module temperature in degrees C above which a minor alarm will be triggered.
1.3.6.1.4.1.2474.1.4.1.1.1.9ColumnaviciBayTempCriticalThresholdread-onlycurrentThe incoming ambient air temperature in degrees C above which a critical alarm will be triggered.
1.3.6.1.4.1.2474.1.4.1.1.1.10ColumnaviciBayTempMajorThresholdread-onlycurrentThe incoming ambient air temperature in degrees C above which a major alarm will be triggered.
1.3.6.1.4.1.2474.1.4.1.1.1.11ColumnaviciBayTempMinorThresholdread-onlycurrentThe incoming ambient air temperature in degrees C above which a minor alarm will be triggered.
1.3.6.1.4.1.2474.1.4.1.2TableaviciBayControllerTablenot-accessiblecurrentThis table contains parameters and state variables for the bay controller.
1.3.6.1.4.1.2474.1.4.1.2.1RowaviciBayControllerEntrynot-accessiblecurrentA list of status and parameter values for each bay.
1.3.6.1.4.1.2474.1.4.1.2.1.1ColumnaviciBayControllerIndexread-onlycurrentThe index number of the bay controller entry.
1.3.6.1.4.1.2474.1.4.1.2.1.2ColumnaviciBayControllerOperStatusread-onlycurrentThe current operational status of the bay controller.
1.3.6.1.4.1.2474.1.4.1.2.1.3ColumnaviciBayControllerAdminStatusread-writecurrentThe current admin status of the bay controller.
1.3.6.1.4.1.2474.1.4.1.2.1.4ColumnaviciBayControllerPartNumberread-onlycurrentThe part number of this bay controller object.
1.3.6.1.4.1.2474.1.4.1.2.1.5ColumnaviciBayControllerSerialNumberread-onlycurrentThe serial number of this bay controller object.
1.3.6.1.4.1.2474.1.4.1.2.1.6ColumnaviciBayControllerRevisionread-onlycurrentThe revision number of this bay controller object.
1.3.6.1.4.1.2474.1.4.1.2.1.7ColumnaviciBayControllerSoftwareVersionread-onlycurrentThe version of the software running on this bay controller object.
1.3.6.1.4.1.2474.1.4.1.2.1.8ColumnaviciBayControllerFirmwareVersionread-onlycurrentThe version of the firmware running on this bay controller object.
1.3.6.1.4.1.2474.1.4.1.2.1.9ColumnaviciBayControllerProductIdread-onlycurrentThe product identification number of this bay controller object.
1.3.6.1.4.1.2474.1.4.1.2.1.10ColumnaviciBayControllerProductSerialNumberread-onlycurrentThe product serial number of this bay controller object.
1.3.6.1.4.1.2474.1.4.1.2.1.11ColumnaviciBayControllerProductRevisionread-onlycurrentThe product revision number of this bay controller object.
1.3.6.1.4.1.2474.1.4.1.2.1.12ColumnaviciBayControllerDescrread-onlycurrentA description of this bay controller object.
1.3.6.1.4.1.2474.1.4.1.3TableaviciBayVoltageTablenot-accessiblecurrentThis table contains parameters and state variables for voltage lines and rails. Each bay contains eight voltage rails used for backplane communication.
1.3.6.1.4.1.2474.1.4.1.3.1RowaviciBayVoltageEntrynot-accessiblecurrentA list of status and parameter values for voltage lines and rails.
1.3.6.1.4.1.2474.1.4.1.3.1.1ColumnaviciBayVoltageIndexread-onlycurrentThe index number of the voltage entry.
1.3.6.1.4.1.2474.1.4.1.3.1.2ColumnaviciBayVoltageTyperead-onlycurrentThe type of the voltage entry.
1.3.6.1.4.1.2474.1.4.1.3.1.3ColumnaviciBayVoltageread-onlycurrentThe current actual logical voltage of the line. The logical voltage is the mapped value reported by the AD7870 ADC for the line.
1.3.6.1.4.1.2474.1.4.1.3.1.4ColumnaviciBayVoltageStatusread-onlycurrentThe current state of the voltage device. If no failure has occurred, the value of this object is inSpec.
1.3.6.1.4.1.2474.1.4.1.3.1.5ColumnaviciBayVoltageDescrread-onlycurrentA description of this voltage object.
1.3.6.1.4.1.2474.1.4.1.4TableaviciBayFanTablenot-accessiblecurrentThis table contains parameters and state variables for blowers. There are up to 4 fans in a shelf installed at the bottom of each bay.
1.3.6.1.4.1.2474.1.4.1.4.1RowaviciBayFanEntrynot-accessiblecurrentA list of status and parameter values for a fan controller.
1.3.6.1.4.1.2474.1.4.1.4.1.1ColumnaviciBayFanIndexread-onlycurrentThe index number of the fan entry.
1.3.6.1.4.1.2474.1.4.1.4.1.2ColumnaviciBayFanAdminStatusread-onlycurrentThe current administrative status of the fan.
1.3.6.1.4.1.2474.1.4.1.4.1.3ColumnaviciBayFanOperStatusread-onlycurrentThe current operational status of the fan.
1.3.6.1.4.1.2474.1.4.1.4.1.4ColumnaviciBayFanSpeedread-onlycurrentThe current speed of the fan in RPM.
1.3.6.1.4.1.2474.1.4.1.4.1.5ColumnaviciBayFanCurrTempread-onlycurrentThe current room temp at the fan in degrees C.
1.3.6.1.4.1.2474.1.4.1.4.1.6ColumnaviciBayFanMaxTempread-onlycurrentThe maximum temperature at the fan since the bay controller booted in degrees C.
1.3.6.1.4.1.2474.1.4.1.4.1.7ColumnaviciBayFanLedStatusread-onlycurrent
1.3.6.1.4.1.2474.1.4.1.4.1.8ColumnaviciBayFanCurrFailuresread-onlycurrentThis variable specifies this fan object's current failures. A value of 0 means there are no current failures for this fan object. The value represents a vector…
1.3.6.1.4.1.2474.1.4.1.4.1.9ColumnaviciBayFanDescrread-onlycurrentA description of this fan object.
1.3.6.1.4.1.2474.1.4.1.5TableaviciBaySlotTablenot-accessiblecurrentThis table contains parameters and state variables for the slots.
1.3.6.1.4.1.2474.1.4.1.5.1RowaviciBaySlotEntrynot-accessiblecurrentA list of status and parameter values for each module in a TSR bay.
1.3.6.1.4.1.2474.1.4.1.5.1.1ColumnaviciSlotIndexread-onlycurrentThe index number of the slot entry.
1.3.6.1.4.1.2474.1.4.1.5.1.2ColumnaviciBaySlotStatusread-onlycurrentThe current state of the slot.
1.3.6.1.4.1.2474.1.4.1.5.1.3ColumnaviciBaySlotRxOctetsread-onlycurrentThe total number of slot octets received.
1.3.6.1.4.1.2474.1.4.1.5.1.4ColumnaviciBaySlotRxMessagesread-onlycurrentThe number of successful slot reads.
1.3.6.1.4.1.2474.1.4.1.5.1.5ColumnaviciBaySlotRxDiscardsread-onlycurrentThe total number of slot received messages discarded for any reason.
1.3.6.1.4.1.2474.1.4.1.5.1.6ColumnaviciBaySlotRxProtoErrsread-onlycurrentThe number of slot received messages discarded due to protocol error.
1.3.6.1.4.1.2474.1.4.1.5.1.7ColumnaviciBaySlotRxIOErrsread-onlycurrentThe number of slot received messages discarded due to I/O error.
1.3.6.1.4.1.2474.1.4.1.5.1.8ColumnaviciBaySlotRxTimeoutsread-onlycurrentThe number of slot received messages discarded due to module timeout error.
1.3.6.1.4.1.2474.1.4.1.5.1.9ColumnaviciBaySlotTxOctetsread-onlycurrentThe total number of slot octets sent.
1.3.6.1.4.1.2474.1.4.1.5.1.10ColumnaviciBaySlotTxMessagesread-onlycurrentThe number of successful slot writes.
1.3.6.1.4.1.2474.1.4.1.5.1.11ColumnaviciBaySlotTxDiscardsread-onlycurrentThe total number of slot send messages aborted for any reason.
1.3.6.1.4.1.2474.1.4.1.5.1.12ColumnaviciBaySlotTxProtoErrsread-onlycurrentThe number of slot send messages aborted due to protocol error.
1.3.6.1.4.1.2474.1.4.1.5.1.13ColumnaviciBaySlotTxIOErrsread-onlycurrentThe number of slot send messages aborted due to I/O error.
1.3.6.1.4.1.2474.1.4.1.5.1.14ColumnaviciBaySlotTxTimeoutsread-onlycurrentThe number of slot send messages aborted due to module timeout error.
1.3.6.1.4.1.2474.1.4.1.6TableaviciBayBreakerTablenot-accessiblecurrentThis table contains parameters and state variables for the 48-volt breakers at the top of the TSR chassis. There are 4 mains and 4 backups, one pair for each o…
1.3.6.1.4.1.2474.1.4.1.6.1RowaviciBayBreakerEntrynot-accessiblecurrentThe state and type of each breaker.
1.3.6.1.4.1.2474.1.4.1.6.1.1ColumnaviciBayBreakerIndexread-onlycurrentThe index number of the breaker entry.
1.3.6.1.4.1.2474.1.4.1.6.1.2ColumnaviciBayBreakerTyperead-onlycurrentThe type of the breaker entry.
1.3.6.1.4.1.2474.1.4.1.6.1.3ColumnaviciBayBreakerStatusread-onlycurrentThe current state of the breaker.
1.3.6.1.4.1.2474.1.4.1.6.1.4ColumnaviciBayBreakerDescrread-onlycurrentA description of this breaker object.
1.3.6.1.4.1.2474.1.4.1.7NodeaviciBayCoAlarmSystem
1.3.6.1.4.1.2474.1.4.1.7.1ScalaraviciBayCoActiveAlarmCountread-onlycurrentThe number of current events causing central office alarms in this Avici bay. If there are no such current events, this object contains the value 0
1.3.6.1.4.1.2474.1.4.1.7.2ScalaraviciBayCoAlarmLastChangeread-onlycurrentThe value of sysUpTime at the time the aviciBayCoAlarmTable changed.
1.3.6.1.4.1.2474.1.4.1.8TableaviciBayCoAlarmTablenot-accessiblecurrentThis table contains any currently active central office alarms.
1.3.6.1.4.1.2474.1.4.1.8.1RowaviciBayCoAlarmEntrynot-accessiblecurrentA description of each active central office alarm.
1.3.6.1.4.1.2474.1.4.1.8.1.1ColumnaviciBayCoAlarmIndexread-onlycurrentThe index of this central office alarm on this bay.
1.3.6.1.4.1.2474.1.4.1.8.1.2ColumnaviciBayCoAlarmTyperead-onlycurrentThe severity level of this central office alarm.
1.3.6.1.4.1.2474.1.4.1.8.1.3ColumnaviciBayCoAlarmDescrread-onlycurrentA description of the event that caused this central office alarm.
1.3.6.1.4.1.2474.1.4.1.8.1.4ColumnaviciBayCoAlarmTimeread-onlycurrentThe time this event occurred in hundreths of a second since the last time the system was rebooted.
1.3.6.1.4.1.2474.1.4.1.8.1.5ColumnaviciBayCoAlarmUnitNumread-onlycurrentThe identification number of the failing component. If there is more than one failing component of the same unit type in a bay, then the identification number …
1.3.6.1.4.1.2474.1.4.1.8.1.6ColumnaviciBayCoAlarmUnitTyperead-onlycurrentThe type of the failing component. If there is more than one failing component of the same unit type in a bay, for example, a fan, then this value is multipleF…
1.3.6.1.4.1.2474.1.4.2NodeaviciBayNotifications
1.3.6.1.4.1.2474.1.4.2.0NodeaviciBayNotificationPrefix
1.3.6.1.4.1.2474.1.4.2.0.1NotificationaviciBayVoltageNotificationcurrentA Voltage notification is sent when a change is detected in the 5 volt backplane communication rails. These backplane communication rails are used by the bay c…
1.3.6.1.4.1.2474.1.4.2.0.2NotificationaviciBayFanNotificationcurrentA Fan notification is sent when the specified fan detects a fault or clears a fault. The current ambient air temperature entering the fan is reported in the av…
1.3.6.1.4.1.2474.1.4.2.0.3NotificationaviciBayBreakerNotificationcurrentA Breaker notification is sent when the specified breaker has tripped or been manually reset. The breaker may have tripped due to a short circuit, excessive cu…
1.3.6.1.4.1.2474.1.4.2.0.4NotificationaviciBayMultiFanFailurescurrentTwo or more fans have failed in this bay.
1.3.6.1.4.1.2474.1.4.2.0.5NotificationaviciBayMultiBayControllerFailurescurrentBoth bay controllers have failed in this bay.
1.3.6.1.4.1.2474.1.4.3NodeaviciBayControllerNotifications
1.3.6.1.4.1.2474.1.4.3.0NodeaviciBayControllerNotificationPrefix
1.3.6.1.4.1.2474.1.4.3.0.1NotificationaviciBayControllerColdStartcurrentThe aviciBayControllerColdStart notification signifies that the bay controller has powered-up.
1.3.6.1.4.1.2474.1.4.3.0.2NotificationaviciBayControllerWarmStartcurrentThe aviciBayControllerWarmStart notification signifies that the bay controller has been restarted.
1.3.6.1.4.1.2474.1.4.3.0.3NotificationaviciBayControllerDowncurrentThe aviciBayControllerDown notification signifies that a server is no longer communicating with the bay controller after having established communication.
1.3.6.1.4.1.2474.1.4.4NodeaviciBayMIBConformance
1.3.6.1.4.1.2474.1.4.4.1NodeaviciBayMIBCompliances
1.3.6.1.4.1.2474.1.4.4.1.1ComplianceaviciBayMIBCompliancecurrentThe compliance statement for the aviciBay.
1.3.6.1.4.1.2474.1.4.4.2NodeaviciBayMIBGroups
1.3.6.1.4.1.2474.1.4.4.2.1GroupaviciBayGroupcurrentObjects for the bay.
1.3.6.1.4.1.2474.1.4.4.2.2GroupaviciBayControllerGroupcurrentObjects for the bayController.
1.3.6.1.4.1.2474.1.4.4.2.3GroupaviciBayCentralOfficeGroupcurrentObjects for the central office.
1.3.6.1.4.1.2474.1.4.4.2.4GroupaviciBayNotificationGroupcurrentNotifications for the bay.