AdaptecArrayController-MIB
171 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | enterprises |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.795 | Nodeadaptec | |||
| 1.3.6.1.4.1.795.3 | Nodeproducts | |||
| 1.3.6.1.4.1.795.3.5 | NodeadaptecArrayController | |||
| 1.3.6.1.4.1.795.3.5.1 | NodeaacDriveLetterChange | A Drive Letter Changed on controller $1 for container $2. | ||
| 1.3.6.1.4.1.795.3.5.1 | ScalaradaptecArrayControllerSoftwareVersion | read-only | mandatory | Version information for the Adaptec Array Controller Software Suite. |
| 1.3.6.1.4.1.795.3.5.2 | NodeaacFailoverChange | A change in failover assignments occured on controller $1. | ||
| 1.3.6.1.4.1.795.3.5.2 | ScalaradaptecArrayControllerAdapterNumber | read-only | mandatory | The Number of Adaptec Array Controllers present in the system. |
| 1.3.6.1.4.1.795.3.5.3 | NodeaacContainerStateChange | A container changed its state on controller $1. Container : $2. | ||
| 1.3.6.1.4.1.795.3.5.3 | TableadaptecArrayControllerAdapterTable | not-accessible | mandatory | A list of Adaptec Array Controller entries. The number of entries is given by AdaptecArrayControllerAdapterNumber. |
| 1.3.6.1.4.1.795.3.5.3.1 | RowadaptecArrayControllerAdapterEntry | not-accessible | mandatory | Descriptive and Status Information for an Adaptec Array Controller. |
| 1.3.6.1.4.1.795.3.5.3.1.1 | ColumnadaptecArrayControllerAdapterIndex | read-only | mandatory | A unique index into the AdaptecArrayControllerAdapterTable. This ranges between 1 and the value of AdaptecArrayControllerAdapterNumber. |
| 1.3.6.1.4.1.795.3.5.3.1.2 | ColumnadaptecArrayControllerAdapterDescription | read-only | mandatory | The Adaptec Array Controller description for this adapter. |
| 1.3.6.1.4.1.795.3.5.3.1.3 | ColumnadaptecArrayControllerAdapterType | read-only | mandatory | The model name of this Adaptec Array Controller. |
| 1.3.6.1.4.1.795.3.5.3.1.4 | ColumnadaptecArrayControllerAdapterVersion | read-only | mandatory | The hardware and software version string for this Adaptec Array Controller. |
| 1.3.6.1.4.1.795.3.5.3.1.5 | ColumnadaptecArrayControllerAdapterChannelCount | read-only | mandatory | The number of channels supported by this Adaptec Array Controller. |
| 1.3.6.1.4.1.795.3.5.3.1.6 | ColumnadaptecArrayControllerAdapterStatus | read-only | mandatory | The status of the controller. This status reflects the status of all containers and devices connected to the controller. |
| 1.3.6.1.4.1.795.3.5.3.1.7 | ColumnadaptecArrayControllerAdapterBiosVersion | read-only | mandatory | The BIOS software version. |
| 1.3.6.1.4.1.795.3.5.3.1.8 | ColumnadaptecArrayControllerAdapterKernelVersion | read-only | mandatory | The kernel software version. |
| 1.3.6.1.4.1.795.3.5.3.1.9 | ColumnadaptecArrayControllerAdapterMonitorVersion | read-only | mandatory | The monitor software version. |
| 1.3.6.1.4.1.795.3.5.3.1.10 | ColumnadaptecArrayControllerAdapterHardwareVersion | read-only | mandatory | The hardware version of the controller. |
| 1.3.6.1.4.1.795.3.5.3.1.11 | ColumnadaptecArrayControllerAdapterTotalMemory | read-only | mandatory | The total amount of memory present in the controller expressed in bytes. |
| 1.3.6.1.4.1.795.3.5.3.1.12 | ColumnadaptecArrayControllerAdapterProgramMemory | read-only | mandatory | The total amount of program memory present in the controller expressed in bytes. |
| 1.3.6.1.4.1.795.3.5.3.1.13 | ColumnadaptecArrayControllerAdapterBufferMemory | read-only | mandatory | The total amount of buffer memory present in the controller expressed in bytes. |
| 1.3.6.1.4.1.795.3.5.4 | NodeaacFileSystemChange | A file system change has occured on container $2 on controller $1. | ||
| 1.3.6.1.4.1.795.3.5.4 | TableadaptecArrayControllerContainerTable | not-accessible | mandatory | A list of Adaptec Array Controller Container Entries. There will one entry in this table for each container on the host. |
| 1.3.6.1.4.1.795.3.5.4.1 | RowadaptecArrayControllerContainerEntry | not-accessible | mandatory | Descriptive and status information for containers hosted by Adaptec Array Controller. |
| 1.3.6.1.4.1.795.3.5.4.1.1 | ColumnadaptecArrayControllerContIndex | read-only | mandatory | An internal index used to identify this container. |
| 1.3.6.1.4.1.795.3.5.4.1.2 | ColumnadaptecArrayControllerContAdapterIndex | read-only | mandatory | An index into the AdaptecArrayControllerAdapterTable that specified the AAC Controller to which this container belongs. |
| 1.3.6.1.4.1.795.3.5.4.1.3 | ColumnadaptecArrayControllerContNumber | read-only | mandatory | An AAC container ID. |
| 1.3.6.1.4.1.795.3.5.4.1.4 | ColumnadaptecArrayControllerContSize | read-only | mandatory | The size of the container in megabytes. |
| 1.3.6.1.4.1.795.3.5.4.1.5 | ColumnadaptecArrayControllerContMountPoint | read-only | mandatory | A string representing drive letters and mount points for the container. |
| 1.3.6.1.4.1.795.3.5.4.1.6 | ColumnadaptecArrayControllerContType | read-only | mandatory | A string representing the container type. |
| 1.3.6.1.4.1.795.3.5.4.1.7 | ColumnadaptecArrayControllerContUsage | read-only | mandatory | A string representing the container's usage. |
| 1.3.6.1.4.1.795.3.5.4.1.8 | ColumnadaptecArrayControllerContStatus | read-only | mandatory | The current status of the container. If a container with a redundant container type is no longer redundant, its status will be marked as nonCritical. If the co… |
| 1.3.6.1.4.1.795.3.5.4.1.9 | ColumnadaptecArrayControllerContStripeSize | read-only | mandatory | The stripe or chunk size of the container in bytes. |
| 1.3.6.1.4.1.795.3.5.5 | TableadaptecArrayControllerDeviceTable | not-accessible | mandatory | A list of devices that are attached to Adaptec Array Controllers that are connected to this host. |
| 1.3.6.1.4.1.795.3.5.5.1 | RowadaptecArrayControllerDeviceEntry | not-accessible | mandatory | Descriptive and status information for devices connected to Adaptec Array Controllers. |
| 1.3.6.1.4.1.795.3.5.5.1.1 | ColumnadaptecArrayControllerDevIndex | read-only | mandatory | An internally used identifier. |
| 1.3.6.1.4.1.795.3.5.5.1.2 | ColumnadaptecArrayControllerDevAdapterIndex | read-only | mandatory | An index into the AdaptecArrayControllerAdapterTable that specified the AAC Controller to which this container belongs. |
| 1.3.6.1.4.1.795.3.5.5.1.3 | ColumnadaptecArrayControllerDevChannelId | read-only | mandatory | The channel that the device is connected to. |
| 1.3.6.1.4.1.795.3.5.5.1.4 | ColumnadaptecArrayControllerDevId | read-only | mandatory | The Device ID. |
| 1.3.6.1.4.1.795.3.5.5.1.5 | ColumnadaptecArrayControllerDevLogicalNumber | read-only | mandatory | The Logical Device ID. |
| 1.3.6.1.4.1.795.3.5.5.1.6 | ColumnadaptecArrayControllerDevType | read-only | mandatory | The Device Type. |
| 1.3.6.1.4.1.795.3.5.5.1.7 | ColumnadaptecArrayControllerDevVendor | read-only | mandatory | The Device Vendor. |
| 1.3.6.1.4.1.795.3.5.5.1.8 | ColumnadaptecArrayControllerDevProduct | read-only | mandatory | The Product Identifier. |
| 1.3.6.1.4.1.795.3.5.5.1.9 | ColumnadaptecArrayControllerDevRevision | read-only | mandatory | The Product Revision. |
| 1.3.6.1.4.1.795.3.5.5.1.10 | ColumnadaptecArrayControllerDevBlocks | read-only | mandatory | The Number of Blocks on the Device. |
| 1.3.6.1.4.1.795.3.5.5.1.11 | ColumnadaptecArrayControllerDevBytesPerBlock | read-only | mandatory | The Number of Bytes Per Block on the Device. |
| 1.3.6.1.4.1.795.3.5.5.1.12 | ColumnadaptecArrayControllerDevUsage | read-only | mandatory | The manner of usage by the Adaptec Array Controller. |
| 1.3.6.1.4.1.795.3.5.5.1.13 | ColumnadaptecArrayControllerDevStatus | read-only | mandatory | The status of the device. |
| 1.3.6.1.4.1.795.3.5.6 | NodeaacGeneralContainerFailure | An unknown error occured on container $2 on adapter $1. | ||
| 1.3.6.1.4.1.795.3.5.6 | TableadaptecArrayControllerContainerToDeviceTable | not-accessible | mandatory | A table used to correlate physical devices to containers. |
| 1.3.6.1.4.1.795.3.5.6.1 | RowadaptecArrayControllerContainerToDeviceEntry | not-accessible | mandatory | Each record of this type represents a row in a table that is used to list the physical devices that are used to make up a container. Each row includes an index… |
| 1.3.6.1.4.1.795.3.5.6.1.1 | ColumnadaptecArrayControllerContainerToDeviceIndex | read-only | mandatory | A unique index into the adaptecArrayControllerContainerToDeviceTable that can be used to identify each row in the table. |
| 1.3.6.1.4.1.795.3.5.6.1.2 | ColumnadaptecArrayControllerCDAdapterIndex | read-only | mandatory | An index into the adapterArrayControllerTable indicating the controller hosting the container being described. |
| 1.3.6.1.4.1.795.3.5.6.1.3 | ColumnadaptecArrayControllerContainerIndex | read-only | mandatory | An index into the adaptecArrayControllerContainerEntry table indicating the container being described. |
| 1.3.6.1.4.1.795.3.5.6.1.4 | ColumnadaptecArrayControllerDeviceIndex | read-only | mandatory | An index into the AdaptecArrayControllerDeviceEntry table indicating the device on which a piece of the container resides. |
| 1.3.6.1.4.1.795.3.5.6.1.5 | ColumnadaptecArrayControllerPartitionOffsetLSW | read-only | mandatory | The least significant 32 bits of the offset into the physical disk to the start of the partition that is used by the referenced container. |
| 1.3.6.1.4.1.795.3.5.6.1.6 | ColumnadaptecArrayControllerPartitionOffsetMSW | read-only | mandatory | The most significant 32 bits of the offset into the physical disk to the start of the partition that is used by the referenced container. |
| 1.3.6.1.4.1.795.3.5.6.1.7 | ColumnadaptecArrayControllerPartitionSizeLSW | read-only | mandatory | The least significant 32 bits of the size of partition on the device used by the referenced container. |
| 1.3.6.1.4.1.795.3.5.6.1.8 | ColumnadaptecArrayControllerPartitionSizeMSW | read-only | mandatory | The most significant 32 bits of the size of partition on the device used by the referenced container. |
| 1.3.6.1.4.1.795.3.5.7 | NodeaacMirrorNotMirroring | The container $2 on controller $1 is no longer in the mirroring state. | ||
| 1.3.6.1.4.1.795.3.5.8 | NodeaacMirrorFailureNoSpace | A failover operation for controller $1 container $2 failed because there was not enough space available on the failover device. | ||
| 1.3.6.1.4.1.795.3.5.9 | NodeaacMirrorFailureNoUnmirror | The container $2 on controller $1 could not be unmirrored. | ||
| 1.3.6.1.4.1.795.3.5.10 | NodeaacMirrorFailoverStarted | A mirror failover operation started on controller $1 for container $2. | ||
| 1.3.6.1.4.1.795.3.5.11 | NodeaacMirrorFailoverFailed | A failover operation on controller $1 failed for container $2. | ||
| 1.3.6.1.4.1.795.3.5.12 | NodeaacMirrorNoFailoverAssigned | There is no failover device assigned to container $2 on controller $1. | ||
| 1.3.6.1.4.1.795.3.5.13 | NodeaacMirrorDriveFailure | A drive that was part of the mirror set (container) $2 failed. This occurred on controller $1. | ||
| 1.3.6.1.4.1.795.3.5.14 | NodeaacRaidRebuildStart | A rebuild operation started on controller $1 for container $2. | ||
| 1.3.6.1.4.1.795.3.5.15 | NodeaacRaidRebuildRestart | A rebuild operation was restarted on controller $1 for container $2. | ||
| 1.3.6.1.4.1.795.3.5.16 | NodeaacRaidDriveFailure | A drive that was part of the RAID set (container) $2 failed. This occurred on controller $1. | ||
| 1.3.6.1.4.1.795.3.5.17 | NodeaacRaidNoFailover | There is no failover device assigned to container $2 on controller $1. | ||
| 1.3.6.1.4.1.795.3.5.18 | NodeaacRaidNoSpace | A failover operation for controller $1 container $2 failed because there is not enough space available on the failover device. | ||
| 1.3.6.1.4.1.795.3.5.19 | NodeaacSnapshotContainerAlmostFull | The snapshot container $2 on controller $1 is almost full. | ||
| 1.3.6.1.4.1.795.3.5.20 | NodeaacSnapshotContainerFull | The snapshot container $2 on controller $1 is full. | ||
| 1.3.6.1.4.1.795.3.5.20 | TableadaptecArrayControllerEnclosureTable | not-accessible | mandatory | A list of enclosures that are attached to Adaptec Array Controllers on this host. |
| 1.3.6.1.4.1.795.3.5.20.1 | RowadaptecArrayControllerEnclosureEntry | not-accessible | mandatory | Descriptive and status information for enclosures connected to Adaptec Array Controllers. |
| 1.3.6.1.4.1.795.3.5.20.1.1 | ColumnadaptecArrayControllerEnclosureIndex | read-only | mandatory | Index into the Enclosure table. |
| 1.3.6.1.4.1.795.3.5.20.1.2 | ColumnadaptecArrayControllerEnclosureAdapterIndex | read-only | mandatory | An index into the AdaptecArrayControllerAdapterTable that specifies the AAC Controller to which this enclosure belongs. |
| 1.3.6.1.4.1.795.3.5.20.1.3 | ColumnadaptecArrayControllerEnclosureProcessorId | read-only | mandatory | The enclosure processor ID assigned on a per adapter basis. |
| 1.3.6.1.4.1.795.3.5.20.1.4 | ColumnadaptecArrayControllerEnclosureType | read-only | mandatory | Standard adhered to for this enclosure. |
| 1.3.6.1.4.1.795.3.5.20.1.5 | ColumnadaptecArrayControllerEnclosureNumberFans | read-only | mandatory | Number of fans for this enclosure. |
| 1.3.6.1.4.1.795.3.5.20.1.6 | ColumnadaptecArrayControllerEnclosureNumberPowerSupplies | read-only | mandatory | Number of power supplies for this enclosure. |
| 1.3.6.1.4.1.795.3.5.20.1.7 | ColumnadaptecArrayControllerEnclosureNumberSlots | read-only | mandatory | Number of slots for this enclosure. |
| 1.3.6.1.4.1.795.3.5.20.1.8 | ColumnadaptecArrayControllerEnclosureDoorLock | read-only | mandatory | Whether or not this enclosure has a host controllable door lock. |
| 1.3.6.1.4.1.795.3.5.20.1.9 | ColumnadaptecArrayControllerEnclosureNumberTemperatureSensors | read-only | mandatory | Number of temperature sensors for this enclosure. |
| 1.3.6.1.4.1.795.3.5.20.1.10 | ColumnadaptecArrayControllerEnclosureSpeaker | read-only | mandatory | Whether or not this enclosure has a speaker installed. |
| 1.3.6.1.4.1.795.3.5.20.1.11 | ColumnadaptecArrayControllerEnclosureBootTimeDiagnostic | read-only | mandatory | Boot time diagnostic value for this enclosure. |
| 1.3.6.1.4.1.795.3.5.20.1.12 | ColumnadaptecArrayControllerEnclosureVendor | read-only | mandatory | Vendor (from SCSI Inquiry) for this enclosure. |
| 1.3.6.1.4.1.795.3.5.20.1.13 | ColumnadaptecArrayControllerEnclosureProduct | read-only | mandatory | Product (from SCSI Inquiry) for this enclosure. |
| 1.3.6.1.4.1.795.3.5.20.1.14 | ColumnadaptecArrayControllerEnclosureRevision | read-only | mandatory | Revision (from SCSI Inquiry) for this enclosure. |
| 1.3.6.1.4.1.795.3.5.20.1.15 | ColumnadaptecArrayControllerEnclosureIdLow | read-only | mandatory | Unique ID number for this enclosure (least significant bits) (from SCSI Inquiry). |
| 1.3.6.1.4.1.795.3.5.20.1.16 | ColumnadaptecArrayControllerEnclosureIdHigh | read-only | mandatory | Unique Id number for this enclosure (most significant bits) (from SCSI Inquiry). |
| 1.3.6.1.4.1.795.3.5.20.1.17 | ColumnadaptecArrayControllerEnclosureStandardRevision | read-only | mandatory | Revision of standard adhered to for this enclosure (from SCSI Inquiry). |
| 1.3.6.1.4.1.795.3.5.20.1.18 | ColumnadaptecArrayControllerEnclosurePowerOnTime | read-only | mandatory | Total number of power on minutes for this enclosure. |
| 1.3.6.1.4.1.795.3.5.20.1.19 | ColumnadaptecArrayControllerEnclosurePowerCycles | read-only | mandatory | Total number of power cycles for this enclosure. |
| 1.3.6.1.4.1.795.3.5.20.1.20 | ColumnadaptecArrayControllerEnclosureSpeakerStatus | read-only | mandatory | Speaker status (on/off only) for this enclosure. |
| 1.3.6.1.4.1.795.3.5.20.1.21 | ColumnadaptecArrayControllerEnclosureOverTemperature | read-only | mandatory | Indicates whether internal temperature for this enclosure exceeds normal. |
| 1.3.6.1.4.1.795.3.5.21 | NodeaacRaidRebuildComplete | The rebuild operation on controller $1 for container $2 has completed. | ||
| 1.3.6.1.4.1.795.3.5.21 | TableadaptecArrayControllerEnclosureFanTable | not-accessible | mandatory | A list of enclosure fans and their status. |
| 1.3.6.1.4.1.795.3.5.21.1 | RowadaptecArrayControllerEnclosureFanEntry | not-accessible | mandatory | Status information for enclosure fans. |
| 1.3.6.1.4.1.795.3.5.21.1.1 | ColumnadaptecArrayControllerEnclosureFanIndex | read-only | mandatory | Index into the enclosure fan table. |
| 1.3.6.1.4.1.795.3.5.21.1.2 | ColumnadaptecArrayControllerEnclosureFanEnclosureIndex | read-only | mandatory | Index into the enclosure table specifying which enclosure contains this fan. |
| 1.3.6.1.4.1.795.3.5.21.1.3 | ColumnadaptecArrayControllerEnclosureFanStatus | read-only | mandatory | Status of this fan. |
| 1.3.6.1.4.1.795.3.5.22 | NodeaacDeviceFailure | A device has failed. Controller $1. Bus $2. Id $3 Lun $4. | ||
| 1.3.6.1.4.1.795.3.5.22 | TableadaptecArrayControllerEnclosurePowerSupplyTable | not-accessible | mandatory | A list of enclosure power supplies and their status. |
| 1.3.6.1.4.1.795.3.5.22.1 | RowadaptecArrayControllerEnclosurePowerSupplyEntry | not-accessible | mandatory | Status information for enclosure power supplies. |
| 1.3.6.1.4.1.795.3.5.22.1.1 | ColumnadaptecArrayControllerEnclosurePowerSupplyIndex | read-only | mandatory | Index into the enclosure power supply table. |
| 1.3.6.1.4.1.795.3.5.22.1.2 | ColumnadaptecArrayControllerEnclosurePowerSupplyEnclosureIndex | read-only | mandatory | Index into the enclosure table specifying which enclosure contains this power supply. |
| 1.3.6.1.4.1.795.3.5.22.1.3 | ColumnadaptecArrayControllerEnclosurePowerSupplyStatus | read-only | mandatory | Status of this power supply. |
| 1.3.6.1.4.1.795.3.5.23 | NodeaacControllerResume | The controller $1 resumed normal I/O operations. | ||
| 1.3.6.1.4.1.795.3.5.23 | TableadaptecArrayControllerEnclosureDoorLockTable | not-accessible | mandatory | A list of enclosure door locks and their status. |
| 1.3.6.1.4.1.795.3.5.23.1 | RowadaptecArrayControllerEnclosureDoorLockEntry | not-accessible | mandatory | Status information for enclosure door locks. |
| 1.3.6.1.4.1.795.3.5.23.1.1 | ColumnadaptecArrayControllerEnclosureDoorLockIndex | read-only | mandatory | Index into the enclosure door lock table. |
| 1.3.6.1.4.1.795.3.5.23.1.2 | ColumnadaptecArrayControllerEnclosureDoorLockEnclosureIndex | read-only | mandatory | Index into the enclosure table specifying which enclosure contains this door lock. |
| 1.3.6.1.4.1.795.3.5.23.1.3 | ColumnadaptecArrayControllerEnclosureDoorLockSlot | read-only | mandatory | Specifies the slot number for this door lock. |
| 1.3.6.1.4.1.795.3.5.23.1.4 | ColumnadaptecArrayControllerEnclosureDoorLockStatus | read-only | mandatory | Status of this door lock. |
| 1.3.6.1.4.1.795.3.5.24 | NodeaacInterfaceUp | The AAC management interface is up. | ||
| 1.3.6.1.4.1.795.3.5.24 | TableadaptecArrayControllerEnclosureTemperatureSensorTable | not-accessible | mandatory | A list of enclosure temperature sensors and their status. |
| 1.3.6.1.4.1.795.3.5.24.1 | RowadaptecArrayControllerEnclosureTemperatureSensorEntry | not-accessible | mandatory | Status information for enclosure temperature sensors. |
| 1.3.6.1.4.1.795.3.5.24.1.1 | ColumnadaptecArrayControllerEnclosureTemperatureSensorIndex | read-only | mandatory | Index into the enclosure temperature sensor table. |
| 1.3.6.1.4.1.795.3.5.24.1.2 | ColumnadaptecArrayControllerEnclosureTemperatureSensorEnclosureIndex | read-only | mandatory | Index into the enclosure table specifying which enclosure contains this temperature sensor. |
| 1.3.6.1.4.1.795.3.5.24.1.3 | ColumnadaptecArrayControllerEnclosureTemperatureSensorOverTemperature | read-only | mandatory | Specifies whether this temperature sensor has detected an over temperature condition. |
| 1.3.6.1.4.1.795.3.5.24.1.4 | ColumnadaptecArrayControllerEnclosureTemperatureSensorDegrees | read-only | mandatory | Temperature registered by this sensor in degrees Fahrenheit. |
| 1.3.6.1.4.1.795.3.5.25 | NodeaacBatteryReconditionRequired | The controller $1 requires battery reconditioning. | ||
| 1.3.6.1.4.1.795.3.5.25 | TableadaptecArrayControllerEnclosureScsiIdTable | not-accessible | mandatory | A list of enclosure SCSI Ids by slot. |
| 1.3.6.1.4.1.795.3.5.25.1 | RowadaptecArrayControllerEnclosureScsiIdEntry | not-accessible | mandatory | Scsi Id information for enclosure slots. |
| 1.3.6.1.4.1.795.3.5.25.1.1 | ColumnadaptecArrayControllerEnclosureScsiIdIndex | read-only | mandatory | Index into the enclosure Scsi Id table. |
| 1.3.6.1.4.1.795.3.5.25.1.2 | ColumnadaptecArrayControllerEnclosureScsiIdEnclosureIndex | read-only | mandatory | Index into the enclosure table specifying which enclosure contains this slot. |
| 1.3.6.1.4.1.795.3.5.25.1.3 | ColumnadaptecArrayControllerEnclosureScsiIdSlot | read-only | mandatory | Specifies the slot number for this Scsi Id. |
| 1.3.6.1.4.1.795.3.5.25.1.4 | ColumnadaptecArrayControllerEnclosureChannelId | read-only | mandatory | Channel Id of device in this slot. |
| 1.3.6.1.4.1.795.3.5.25.1.5 | ColumnadaptecArrayControllerEnclosureScsiId | read-only | mandatory | SCSI Id of device in this slot. |
| 1.3.6.1.4.1.795.3.5.25.1.6 | ColumnadaptecArrayControllerEnclosureLunId | read-only | mandatory | Logical Unit Id of device in this slot. |
| 1.3.6.1.4.1.795.3.5.26 | NodeaacEnclosureGeneralError | An enclosure connected to controller $1 has reported an error. | ||
| 1.3.6.1.4.1.795.3.5.26 | TableadaptecArrayControllerEnclosureDeviceInsertionTable | not-accessible | mandatory | A list of enclosure device insertion counts by slot. |
| 1.3.6.1.4.1.795.3.5.26.1 | RowadaptecArrayControllerEnclosureDeviceInsertionEntry | not-accessible | mandatory | Count information for enclosure device insertions. |
| 1.3.6.1.4.1.795.3.5.26.1.1 | ColumnadaptecArrayControllerEnclosureDeviceInsertionIndex | read-only | mandatory | Index into the enclosure device insertion lock table. |
| 1.3.6.1.4.1.795.3.5.26.1.2 | ColumnadaptecArrayControllerEnclosureDeviceInsertionEnclosureIndex | read-only | mandatory | Index into the enclosure table specifying which enclosure contains this slot. |
| 1.3.6.1.4.1.795.3.5.26.1.3 | ColumnadaptecArrayControllerEnclosureDeviceInsertionSlot | read-only | mandatory | Specifies the slot number for this device insertion count. |
| 1.3.6.1.4.1.795.3.5.26.1.4 | ColumnadaptecArrayControllerEnclosureDeviceInsertions | read-only | mandatory | Number of device insertions for this slot. |
| 1.3.6.1.4.1.795.3.5.27 | NodeaacEnclosureFanError | An enclosure connected to controller $1 has reported a fan failure. | ||
| 1.3.6.1.4.1.795.3.5.27 | TableadaptecArrayControllerEnclosureSlotStatusTable | not-accessible | mandatory | A list of enclosure statuses by slot. |
| 1.3.6.1.4.1.795.3.5.27.1 | RowadaptecArrayControllerEnclosureSlotStatusEntry | not-accessible | mandatory | Status information for enclosure slots. |
| 1.3.6.1.4.1.795.3.5.27.1.1 | ColumnadaptecArrayControllerEnclosureSlotStatusIndex | read-only | mandatory | Index into the enclosure slot status table. |
| 1.3.6.1.4.1.795.3.5.27.1.2 | ColumnadaptecArrayControllerEnclosureSlotStatusEnclosureIndex | read-only | mandatory | Index into the enclosure table specifying which enclosure contains this slot. |
| 1.3.6.1.4.1.795.3.5.27.1.3 | ColumnadaptecArrayControllerEnclosureSlotStatusSlot | read-only | mandatory | Specifies the slot number for this slot. |
| 1.3.6.1.4.1.795.3.5.27.1.4 | ColumnadaptecArrayControllerEnclosureSlotStatus | read-only | mandatory | Status of this slot. |
| 1.3.6.1.4.1.795.3.5.28 | NodeaacEnclosurePowerSupplyError | An enclosure connected to controller $1 has reported a power supply failure. | ||
| 1.3.6.1.4.1.795.3.5.29 | NodeaacEnclosureTempAbnormal | An enclosure connected to controller $1 has reported an abnormal temperature reading. | ||
| 1.3.6.1.4.1.795.3.5.30 | NodeaacEnclosureTempOver | An enclosure connected to controller $1 has reported a temperature reading above the user threshold. | ||
| 1.3.6.1.4.1.795.3.5.31 | NodeaacBatteryDead | The battery connected to controller $1 is dead. | ||
| 1.3.6.1.4.1.795.3.5.32 | NodeaacBatteryImproving | The battery connected to controller $1 is improving. | ||
| 1.3.6.1.4.1.795.3.5.33 | NodeaacBatteryDegrading | The battery connected to controller $1 has lost charge. | ||
| 1.3.6.1.4.1.795.3.5.34 | NodeaacBatteryGood | The controller $1 reports that its battery is good. | ||
| 1.3.6.1.4.1.795.3.5.35 | NodeaacControllerPaused | The controller $1 has been paused. | ||
| 1.3.6.1.4.1.795.3.5.36 | NodeaacContainerCreated | Container $2 has been created on controller $1. | ||
| 1.3.6.1.4.1.795.3.5.37 | NodeaacContainerDeleted | Container $2 has been deleted on controller $1. | ||
| 1.3.6.1.4.1.795.3.5.38 | NodeaacDeviceFailurePredictionThresholdExceeded | A device reported that its Failure Prediction Threshold had been exceeded. Controller $1. Bus $2. Id $3 Lun $4. | ||
| 1.3.6.1.4.1.795.3.5.39 | NodeaacDeviceFailurePredictionTest | A Failure Prediction Threshold test occured. Controller $1. Bus $2. Id $3. Lun $4. | ||
| 1.3.6.1.4.1.795.3.5.40 | NodeaacDeviceWarning | A Device issued a warning. Controller $1. Bus $2. Id $3 Lun $4. | ||
| 1.3.6.1.4.1.795.3.5.41 | NodeaacDeviceTemperatureWarning | A Device issued a abnormal temperature warning. Controller $1. Bus $2. Id $3 Lun $4. | ||
| 1.3.6.1.4.1.795.3.5.42 | NodeaacDeviceDegradedWarning | A device reported that its status is degraded. Controller $1. Bus $2. Id $3 Lun $4. | ||
| 1.3.6.1.4.1.795.3.5.43 | NodeaacDeviceFailurePredictionConfigurationChanged | The failure prediction configuration changed for a device. Controller $1. Bus $2. Id $3 Lun $4. | ||
| 1.3.6.1.4.1.795.3.5.9000 | NodeadaptecArrayControllerTraps | |||
| 1.3.6.1.4.1.795.3.5.9000.1 | ScalaraacControllerId | not-accessible | mandatory | Controller ID for this trap. |
| 1.3.6.1.4.1.795.3.5.9000.2 | ScalaraacContainerId | not-accessible | mandatory | Container ID for this trap. |
| 1.3.6.1.4.1.795.3.5.9000.3 | ScalaraacBusId | not-accessible | mandatory | Bus ID for device referred to by this trap. |
| 1.3.6.1.4.1.795.3.5.9000.4 | ScalaraacScsiId | not-accessible | mandatory | SCSI ID for device referred to by this trap. |
| 1.3.6.1.4.1.795.3.5.9000.5 | ScalaraacLunId | not-accessible | mandatory | SCSI LUN ID for device referred to by this trap. |
| 1.3.6.1.4.1.795.3.5.9000.6 | ScalaraacEnclosureProcessorId | not-accessible | mandatory | Enclosure processor ID for enclosure referred to by this trap. |
| 1.3.6.1.4.1.795.3.5.9000.7 | ScalaraacComponentUnitId | not-accessible | mandatory | Component unit ID for enclosure referred to by this trap. |