MIB Viewer

BKTEL-HFC862-OA-V01-MIB

267 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.7501.1.2.116Nodeoa
1.3.6.1.4.1.7501.1.2.116.1NodeoaCommon
1.3.6.1.4.1.7501.1.2.116.1.1ScalaroaCommonNumberOfModulesread-onlymandatoryNumber of modules in table.
1.3.6.1.4.1.7501.1.2.116.1.2TableoaCommonTablenot-accessiblemandatoryThe table contains all modules of the OA-type in the NE
1.3.6.1.4.1.7501.1.2.116.1.2.1RowoaCommonEntrynot-accessiblemandatoryCommon-Values for a module.
1.3.6.1.4.1.7501.1.2.116.1.2.1.1ColumnoaNESlotread-onlymandatoryThe slot number of the chassis for which this entry contains management information.
1.3.6.1.4.1.7501.1.2.116.1.2.1.2ColumnoaCommonTyperead-onlymandatoryThe type of physical module. modSlotEmpty indicates an empty slot. A Value of modSlotUnknown indicates that the type of module is unknown.
1.3.6.1.4.1.7501.1.2.116.1.2.1.3ColumnoaCommonDescrread-writemandatoryA textual description of the module. If not available, this Value should be set to a zero length string.
1.3.6.1.4.1.7501.1.2.116.1.2.1.4ColumnoaCommonFirmwareIdread-onlymandatoryThe firmware Id of the module.
1.3.6.1.4.1.7501.1.2.116.1.2.1.5ColumnoaCommonModuleWidthread-onlyoptionalThe width of the module in multiples of slots (1, 2, ...)
1.3.6.1.4.1.7501.1.2.116.2NodeoaStates
1.3.6.1.4.1.7501.1.2.116.2.1TableoaStatesTablenot-accessiblemandatory
1.3.6.1.4.1.7501.1.2.116.2.1.1RowoaStatesEntrynot-accessiblemandatoryAlarms for a module.
1.3.6.1.4.1.7501.1.2.116.2.1.1.1ColumnoaStatesBootloaderread-onlymandatoryThe device is running in bootloader mode without a legal application software.
1.3.6.1.4.1.7501.1.2.116.2.1.1.2ColumnoaStatesCommLossread-onlymandatoryThe NEC has lost the connection to the device. Reason may be a removed or defective device. Note that this state is set by the NEC and not by the device
1.3.6.1.4.1.7501.1.2.116.2.1.1.3ColumnoaStatesInitializingread-onlymandatoryThe device is initializing
1.3.6.1.4.1.7501.1.2.116.2.1.1.4ColumnoaStatesLaserShutdownread-onlymandatoryLasers are shutdown, no optical output
1.3.6.1.4.1.7501.1.2.116.2.1.1.5ColumnoaStatesTemperatureLowread-onlymandatoryDevice internal temperature low
1.3.6.1.4.1.7501.1.2.116.2.1.1.6ColumnoaStatesTemperatureHighread-onlymandatoryDevice internal temperature high
1.3.6.1.4.1.7501.1.2.116.2.1.1.7ColumnoaStatesSystemread-onlymandatoryInternal error occured
1.3.6.1.4.1.7501.1.2.116.2.1.1.8ColumnoaStatesInputPwrLowread-onlymandatoryOptical input power low
1.3.6.1.4.1.7501.1.2.116.2.1.1.9ColumnoaStatesInputPwrHighread-onlymandatoryOptical input power high
1.3.6.1.4.1.7501.1.2.116.2.1.1.10ColumnoaStatesOutputPwrOrGainLowread-onlymandatoryOptical output power (or gain) low
1.3.6.1.4.1.7501.1.2.116.2.1.1.11ColumnoaStatesOutputPwrOrGainHighread-onlymandatoryOptical output power (or gain) high
1.3.6.1.4.1.7501.1.2.116.2.1.1.12ColumnoaStatesReturnLossLowread-onlymandatoryReturn loss low
1.3.6.1.4.1.7501.1.2.116.2.1.1.13ColumnoaStatesReturnLossHighread-onlymandatoryReturn loss high
1.3.6.1.4.1.7501.1.2.116.2.1.1.14ColumnoaStatesRedundancySwitchread-onlymandatoryThis (redundant) device has been activated (redundancy switchover)
1.3.6.1.4.1.7501.1.2.116.2.1.1.15ColumnoaStatesInputVoltageLowread-onlymandatoryInput supply voltage low
1.3.6.1.4.1.7501.1.2.116.2.1.1.16ColumnoaStatesInputVoltageHighread-onlymandatoryInput supply voltage high
1.3.6.1.4.1.7501.1.2.116.2.1.1.25ColumnoaStatesPowerSupplyLeftread-onlymandatoryThe left (looking from front) power supply unit fails. Only valid for devices in 19 inch housing
1.3.6.1.4.1.7501.1.2.116.2.1.1.26ColumnoaStatesPowerSupplyRightread-onlymandatoryThe right (looking from front) power supply unit fails. Only valid for devices in 19 inch housing
1.3.6.1.4.1.7501.1.2.116.2.1.1.27ColumnoaStatesFanLeftread-onlymandatoryThe left (looking from front) fan unit fails. Only valid for devices in 19 inch housing
1.3.6.1.4.1.7501.1.2.116.2.1.1.28ColumnoaStatesFanRightread-onlymandatoryThe right (looking from front) fan unit fails. Only valid for devices in 19 inch housing
1.3.6.1.4.1.7501.1.2.116.2.1.1.29ColumnoaStatesInternalVoltageLowread-onlymandatoryOne (or more) internal voltages low
1.3.6.1.4.1.7501.1.2.116.2.1.1.30ColumnoaStatesInternalVoltageHighread-onlymandatoryOne (or more) internal voltages high
1.3.6.1.4.1.7501.1.2.116.2.1.1.31ColumnoaStatesLaserCurrentLowread-onlymandatoryLaser current of one (or more) lasers low
1.3.6.1.4.1.7501.1.2.116.2.1.1.32ColumnoaStatesLaserCurrentHighread-onlymandatoryLaser current of one (or more) lasers high (laser is aging)
1.3.6.1.4.1.7501.1.2.116.2.1.1.33ColumnoaStatesTecCurrentLowread-onlymandatoryLaser TEC current limit of one (or more) lasers reached (heating limit)
1.3.6.1.4.1.7501.1.2.116.2.1.1.34ColumnoaStatesTecCurrentHighread-onlymandatoryLaser TEC current limit of one (or more) lasers reached (cooling limit)
1.3.6.1.4.1.7501.1.2.116.2.1.1.35ColumnoaStatesLaserTempLowread-onlymandatoryLaser temperature of one (or more) lasers low
1.3.6.1.4.1.7501.1.2.116.2.1.1.36ColumnoaStatesLaserTempHighread-onlymandatoryLaser temperature of one (or more) lasers high
1.3.6.1.4.1.7501.1.2.116.2.1.1.37ColumnoaStatesLaserVoltageLowread-onlymandatoryLaser voltage supply of one (or more) lasers low
1.3.6.1.4.1.7501.1.2.116.2.1.1.38ColumnoaStatesLaserVoltageHighread-onlymandatoryLaser voltage supply of one (or more) lasers high
1.3.6.1.4.1.7501.1.2.116.2.1.1.39ColumnoaStatesRamanBackReflectionRatioread-onlymandatoryRaman amplifier back reflection ratio high alarm Only used if oaDisplayAmplifierIsRamanType == true(1)
1.3.6.1.4.1.7501.1.2.116.2.1.1.40ColumnoaStatesRamanOscSignalMissingread-onlymandatoryRaman amplifier oscillator signal missing alarm Only used if oaDisplayAmplifierIsRamanType == true(1)
1.3.6.1.4.1.7501.1.2.116.3NodeoaConfiguration
1.3.6.1.4.1.7501.1.2.116.3.1TableoaConfigurationTablenot-accessiblemandatory
1.3.6.1.4.1.7501.1.2.116.3.1.1RowoaConfigurationEntrynot-accessiblemandatory
1.3.6.1.4.1.7501.1.2.116.3.1.1.1ColumnoaConfigNESlotWriteread-writeoptionalBy writing this variable a slot can be assigned for devices that dont support hardware slot detection. Reading '-1' means that the slot position is NOT writabl…
1.3.6.1.4.1.7501.1.2.116.3.1.1.2ColumnoaConfigRegulationModeread-writemandatoryThe regulation mode of the device. - regModeConstantOutputPower(1): If the device runs in constant output power mode, then all *OutputPwrOrGain* variables are …
1.3.6.1.4.1.7501.1.2.116.3.1.1.3ColumnoaConfigOutputPwrOrGainAdjustread-writemandatoryThis variable can be used to adjust the desired output power (or gain) value in 0.1 dB units relative to its nominal level. See oaConfigRegulationMode variable…
1.3.6.1.4.1.7501.1.2.116.3.1.1.4ColumnoaConfigModeExtIOread-writemandatoryThe mode and usage of the device's external IO port.
1.3.6.1.4.1.7501.1.2.116.3.1.1.5ColumnoaConfigMaskExtIOread-writemandatoryThe alarm/warning mask that activates the device's external IO port.
1.3.6.1.4.1.7501.1.2.116.3.1.1.6ColumnoaConfigSbsEvaluationModeread-writemandatoryThe SBS threshold evaluation mode.
1.3.6.1.4.1.7501.1.2.116.4NodeoaControl
1.3.6.1.4.1.7501.1.2.116.4.1TableoaControlTablenot-accessiblemandatory
1.3.6.1.4.1.7501.1.2.116.4.1.1RowoaControlEntrynot-accessiblemandatoryAlarms for a module.
1.3.6.1.4.1.7501.1.2.116.4.1.1.1ColumnoaControlLaserShutdownread-writemandatoryShutdown the laser(s), optical power on/off.
1.3.6.1.4.1.7501.1.2.116.4.1.1.2ColumnoaControlResetread-writemandatoryReset the module.
1.3.6.1.4.1.7501.1.2.116.4.1.1.3ColumnoaControlModuleLedBlinkread-writemandatoryWriting this variable to true(1) lets the device's modul LED blink green for 10 seconds. Writing this variable to false(2) stops blinking at once. This variabl…
1.3.6.1.4.1.7501.1.2.116.4.1.1.4ColumnoaControlSbsEvaluationStartread-writemandatorySetting to true(1) starts an SBS threshold evaluation process. Always reads as false(2)
1.3.6.1.4.1.7501.1.2.116.5NodeoaMeasuringValues
1.3.6.1.4.1.7501.1.2.116.5.1TableoaMeasuringValuesTablenot-accessiblemandatory
1.3.6.1.4.1.7501.1.2.116.5.1.1RowoaMeasuringValuesEntrynot-accessiblemandatoryCommon-Values for a module.
1.3.6.1.4.1.7501.1.2.116.5.1.1.1ColumnoaTemperatureLoLoread-onlymandatoryThe module temperature low alarm threshold in steps of 0.1 celsius degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.2ColumnoaTemperatureLoread-onlymandatoryThe module temperature low warning threshold in steps of 0.1 celsius degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.3ColumnoaTemperatureValueread-onlymandatoryThe module temperature in steps of 0.1 celsius degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.4ColumnoaTemperatureHiread-onlymandatoryThe module temperature high warning threshold in steps of 0.1 celsius degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.5ColumnoaTemperatureHiHiread-onlymandatoryThe module temperature high alarm threshold in steps of 0.1 celsius degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.6ColumnoaInputPowerLoLoread-writemandatoryInput power low alarm threshold in steps of 0.1dBm.
1.3.6.1.4.1.7501.1.2.116.5.1.1.7ColumnoaInputPowerLoread-writemandatoryInput power low warning threshold in steps of 0.1dBm.
1.3.6.1.4.1.7501.1.2.116.5.1.1.8ColumnoaInputPowerValueread-onlymandatoryInput power in steps of 0.1dBm.
1.3.6.1.4.1.7501.1.2.116.5.1.1.9ColumnoaInputPowerHiread-writemandatoryInput power high warning threshold in steps of 0.1dBm.
1.3.6.1.4.1.7501.1.2.116.5.1.1.10ColumnoaInputPowerHiHiread-writemandatoryInput power high alarm threshold in steps of 0.1dBm.
1.3.6.1.4.1.7501.1.2.116.5.1.1.11ColumnoaOutputPwrOrGainLoLoread-writemandatoryOutput power (or gain) low alarm threshold in steps of 0.1dB(m). See oaConfigRegulationMode variable too
1.3.6.1.4.1.7501.1.2.116.5.1.1.12ColumnoaOutputPwrOrGainLoread-writemandatoryOutput power (or gain) low warning threshold in steps of 0.1dB(m). See oaConfigRegulationMode variable too
1.3.6.1.4.1.7501.1.2.116.5.1.1.13ColumnoaOutputPwrOrGainValueread-onlymandatoryOutput power (or gain) in steps of 0.1dB(m). See oaConfigRegulationMode variable too
1.3.6.1.4.1.7501.1.2.116.5.1.1.14ColumnoaOutputPwrOrGainHiread-writemandatoryOutput power (or gain) high warning threshold in steps of 0.1dB(m). See oaConfigRegulationMode variable too
1.3.6.1.4.1.7501.1.2.116.5.1.1.15ColumnoaOutputPwrOrGainHiHiread-writemandatoryOutput power (or gain) high alarm threshold in steps of 0.1dB(m). See oaConfigRegulationMode variable too
1.3.6.1.4.1.7501.1.2.116.5.1.1.16ColumnoaReturnLossLoLoread-writemandatoryReturnLoss low alarm threshold in steps of 0.1 dB.
1.3.6.1.4.1.7501.1.2.116.5.1.1.17ColumnoaReturnLossLoread-writemandatoryReturnLoss low warning threshold in steps of 0.1 dB.
1.3.6.1.4.1.7501.1.2.116.5.1.1.18ColumnoaReturnLossValueread-onlymandatoryReturnLoss in steps of 0.1 dB.
1.3.6.1.4.1.7501.1.2.116.5.1.1.19ColumnoaReturnLossHiread-writemandatoryReturnLoss high warning threshold in steps of 0.1 dB.
1.3.6.1.4.1.7501.1.2.116.5.1.1.20ColumnoaReturnLossHiHiread-writemandatoryReturnLoss high alarm threshold in steps of 0.1 dB.
1.3.6.1.4.1.7501.1.2.116.5.1.1.21ColumnoaInputVoltageLoLoread-onlymandatoryThe input supply voltage low alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.22ColumnoaInputVoltageLoread-onlymandatoryThe input supply voltage low warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.23ColumnoaInputVoltageValueread-onlymandatoryThe input supply voltage in steps of 0.1 Volts. Input supply voltage nominal value, see 'oaDisplayInputVoltageNominal'
1.3.6.1.4.1.7501.1.2.116.5.1.1.24ColumnoaInputVoltageHiread-onlymandatoryThe input supply voltage high warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.25ColumnoaInputVoltageHiHiread-onlymandatoryThe input supply voltage high alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.46ColumnoaInternalVoltage1LoLoread-onlyoptionalThe internal voltage low alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.47ColumnoaInternalVoltage1Loread-onlyoptionalThe internal voltage low warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.48ColumnoaInternalVoltage1Valueread-onlyoptionalThe internal voltage in steps of 0.1 Volts. Internal voltage nominal value, see 'oaDisplayInternalVoltage1Nominal'
1.3.6.1.4.1.7501.1.2.116.5.1.1.49ColumnoaInternalVoltage1Hiread-onlyoptionalThe internal voltage high warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.50ColumnoaInternalVoltage1HiHiread-onlyoptionalThe internal voltage high alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.51ColumnoaInternalVoltage2LoLoread-onlyoptionalThe internal voltage low alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.52ColumnoaInternalVoltage2Loread-onlyoptionalThe internal voltage low warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.53ColumnoaInternalVoltage2Valueread-onlyoptionalThe internal voltage in steps of 0.1 Volts. Internal voltage nominal value, see 'oaDisplayInternalVoltage2Nominal'
1.3.6.1.4.1.7501.1.2.116.5.1.1.54ColumnoaInternalVoltage2Hiread-onlyoptionalThe internal voltage high warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.55ColumnoaInternalVoltage2HiHiread-onlyoptionalThe internal voltage high alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.56ColumnoaInternalVoltage3LoLoread-onlyoptionalThe internal voltage low alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.57ColumnoaInternalVoltage3Loread-onlyoptionalThe internal voltage low warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.58ColumnoaInternalVoltage3Valueread-onlyoptionalThe internal voltage in steps of 0.1 Volts. Internal voltage nominal value, see 'oaDisplayInternalVoltage3Nominal'
1.3.6.1.4.1.7501.1.2.116.5.1.1.59ColumnoaInternalVoltage3Hiread-onlyoptionalThe internal voltage high warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.60ColumnoaInternalVoltage3HiHiread-onlyoptionalThe internal voltage high alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.86ColumnoaLaser1CurrentRelLoLoread-onlymandatoryRelative laser no.1 current low alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.87ColumnoaLaser1CurrentRelLoread-onlymandatoryRelative laser no.1 current low warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.88ColumnoaLaser1CurrentRelValueread-onlymandatoryThe laser no.1 current relative to the current at begin of life in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.89ColumnoaLaser1CurrentRelHiread-onlymandatoryRelative laser no.1 current high warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.90ColumnoaLaser1CurrentRelHiHiread-onlymandatoryRelative laser no.1 current high alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.91ColumnoaLaser1TecRelLoLoread-onlymandatoryThermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.92ColumnoaLaser1TecRelLoread-onlymandatoryThermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.93ColumnoaLaser1TecRelValueread-onlymandatoryThe thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.94ColumnoaLaser1TecRelHiread-onlymandatoryThermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.95ColumnoaLaser1TecRelHiHiread-onlymandatoryThermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.96ColumnoaLaser1TemperatureLoLoread-onlymandatoryTemperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.97ColumnoaLaser1TemperatureLoread-onlymandatoryTemperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.98ColumnoaLaser1TemperatureValueread-onlymandatoryTemperature of laser no.1 in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.99ColumnoaLaser1TemperatureHiread-onlymandatoryTemperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.100ColumnoaLaser1TemperatureHiHiread-onlymandatoryTemperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.101ColumnoaLaser1VoltageLoLoread-onlyoptionalThe supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.102ColumnoaLaser1VoltageLoread-onlyoptionalThe supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.103ColumnoaLaser1VoltageValueread-onlyoptionalThe supply voltage of laser no.1 in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.104ColumnoaLaser1VoltageHiread-onlyoptionalThe supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.105ColumnoaLaser1VoltageHiHiread-onlyoptionalThe supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.111ColumnoaLaser2CurrentRelLoLoread-onlymandatoryRelative laser no.1 current low alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.112ColumnoaLaser2CurrentRelLoread-onlymandatoryRelative laser no.1 current low warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.113ColumnoaLaser2CurrentRelValueread-onlymandatoryThe laser no.1 current relative to the current at begin of life in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.114ColumnoaLaser2CurrentRelHiread-onlymandatoryRelative laser no.1 current high warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.115ColumnoaLaser2CurrentRelHiHiread-onlymandatoryRelative laser no.1 current high alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.116ColumnoaLaser2TecRelLoLoread-onlymandatoryThermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.117ColumnoaLaser2TecRelLoread-onlymandatoryThermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.118ColumnoaLaser2TecRelValueread-onlymandatoryThe thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.119ColumnoaLaser2TecRelHiread-onlymandatoryThermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.120ColumnoaLaser2TecRelHiHiread-onlymandatoryThermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.121ColumnoaLaser2TemperatureLoLoread-onlymandatoryTemperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.122ColumnoaLaser2TemperatureLoread-onlymandatoryTemperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.123ColumnoaLaser2TemperatureValueread-onlymandatoryTemperature of laser no.1 in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.124ColumnoaLaser2TemperatureHiread-onlymandatoryTemperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.125ColumnoaLaser2TemperatureHiHiread-onlymandatoryTemperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.126ColumnoaLaser2VoltageLoLoread-onlyoptionalThe supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.127ColumnoaLaser2VoltageLoread-onlyoptionalThe supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.128ColumnoaLaser2VoltageValueread-onlyoptionalThe supply voltage of laser no.1 in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.129ColumnoaLaser2VoltageHiread-onlyoptionalThe supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.130ColumnoaLaser2VoltageHiHiread-onlyoptionalThe supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.136ColumnoaLaser3CurrentRelLoLoread-onlymandatoryRelative laser no.1 current low alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.137ColumnoaLaser3CurrentRelLoread-onlymandatoryRelative laser no.1 current low warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.138ColumnoaLaser3CurrentRelValueread-onlymandatoryThe laser no.1 current relative to the current at begin of life in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.139ColumnoaLaser3CurrentRelHiread-onlymandatoryRelative laser no.1 current high warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.140ColumnoaLaser3CurrentRelHiHiread-onlymandatoryRelative laser no.1 current high alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.141ColumnoaLaser3TecRelLoLoread-onlymandatoryThermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.142ColumnoaLaser3TecRelLoread-onlymandatoryThermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.143ColumnoaLaser3TecRelValueread-onlymandatoryThe thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.144ColumnoaLaser3TecRelHiread-onlymandatoryThermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.145ColumnoaLaser3TecRelHiHiread-onlymandatoryThermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.146ColumnoaLaser3TemperatureLoLoread-onlymandatoryTemperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.147ColumnoaLaser3TemperatureLoread-onlymandatoryTemperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.148ColumnoaLaser3TemperatureValueread-onlymandatoryTemperature of laser no.1 in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.149ColumnoaLaser3TemperatureHiread-onlymandatoryTemperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.150ColumnoaLaser3TemperatureHiHiread-onlymandatoryTemperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.151ColumnoaLaser3VoltageLoLoread-onlyoptionalThe supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.152ColumnoaLaser3VoltageLoread-onlyoptionalThe supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.153ColumnoaLaser3VoltageValueread-onlyoptionalThe supply voltage of laser no.1 in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.154ColumnoaLaser3VoltageHiread-onlyoptionalThe supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.155ColumnoaLaser3VoltageHiHiread-onlyoptionalThe supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.161ColumnoaLaser4CurrentRelLoLoread-onlymandatoryRelative laser no.1 current low alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.162ColumnoaLaser4CurrentRelLoread-onlymandatoryRelative laser no.1 current low warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.163ColumnoaLaser4CurrentRelValueread-onlymandatoryThe laser no.1 current relative to the current at begin of life in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.164ColumnoaLaser4CurrentRelHiread-onlymandatoryRelative laser no.1 current high warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.165ColumnoaLaser4CurrentRelHiHiread-onlymandatoryRelative laser no.1 current high alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.166ColumnoaLaser4TecRelLoLoread-onlymandatoryThermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.167ColumnoaLaser4TecRelLoread-onlymandatoryThermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.168ColumnoaLaser4TecRelValueread-onlymandatoryThe thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.169ColumnoaLaser4TecRelHiread-onlymandatoryThermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.170ColumnoaLaser4TecRelHiHiread-onlymandatoryThermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.171ColumnoaLaser4TemperatureLoLoread-onlymandatoryTemperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.172ColumnoaLaser4TemperatureLoread-onlymandatoryTemperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.173ColumnoaLaser4TemperatureValueread-onlymandatoryTemperature of laser no.1 in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.174ColumnoaLaser4TemperatureHiread-onlymandatoryTemperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.175ColumnoaLaser4TemperatureHiHiread-onlymandatoryTemperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.176ColumnoaLaser4VoltageLoLoread-onlyoptionalThe supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.177ColumnoaLaser4VoltageLoread-onlyoptionalThe supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.178ColumnoaLaser4VoltageValueread-onlyoptionalThe supply voltage of laser no.1 in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.179ColumnoaLaser4VoltageHiread-onlyoptionalThe supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.180ColumnoaLaser4VoltageHiHiread-onlyoptionalThe supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.186ColumnoaLaser5CurrentRelLoLoread-onlymandatoryRelative laser no.1 current low alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.187ColumnoaLaser5CurrentRelLoread-onlymandatoryRelative laser no.1 current low warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.188ColumnoaLaser5CurrentRelValueread-onlymandatoryThe laser no.1 current relative to the current at begin of life in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.189ColumnoaLaser5CurrentRelHiread-onlymandatoryRelative laser no.1 current high warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.190ColumnoaLaser5CurrentRelHiHiread-onlymandatoryRelative laser no.1 current high alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.191ColumnoaLaser5TecRelLoLoread-onlymandatoryThermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.192ColumnoaLaser5TecRelLoread-onlymandatoryThermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.193ColumnoaLaser5TecRelValueread-onlymandatoryThe thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.194ColumnoaLaser5TecRelHiread-onlymandatoryThermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.195ColumnoaLaser5TecRelHiHiread-onlymandatoryThermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.196ColumnoaLaser5TemperatureLoLoread-onlymandatoryTemperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.197ColumnoaLaser5TemperatureLoread-onlymandatoryTemperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.198ColumnoaLaser5TemperatureValueread-onlymandatoryTemperature of laser no.1 in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.199ColumnoaLaser5TemperatureHiread-onlymandatoryTemperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.200ColumnoaLaser5TemperatureHiHiread-onlymandatoryTemperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.201ColumnoaLaser5VoltageLoLoread-onlyoptionalThe supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.202ColumnoaLaser5VoltageLoread-onlyoptionalThe supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.203ColumnoaLaser5VoltageValueread-onlyoptionalThe supply voltage of laser no.1 in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.204ColumnoaLaser5VoltageHiread-onlyoptionalThe supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.205ColumnoaLaser5VoltageHiHiread-onlyoptionalThe supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.211ColumnoaLaser6CurrentRelLoLoread-onlymandatoryRelative laser no.1 current low alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.212ColumnoaLaser6CurrentRelLoread-onlymandatoryRelative laser no.1 current low warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.213ColumnoaLaser6CurrentRelValueread-onlymandatoryThe laser no.1 current relative to the current at begin of life in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.214ColumnoaLaser6CurrentRelHiread-onlymandatoryRelative laser no.1 current high warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.215ColumnoaLaser6CurrentRelHiHiread-onlymandatoryRelative laser no.1 current high alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.216ColumnoaLaser6TecRelLoLoread-onlymandatoryThermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.217ColumnoaLaser6TecRelLoread-onlymandatoryThermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.218ColumnoaLaser6TecRelValueread-onlymandatoryThe thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.219ColumnoaLaser6TecRelHiread-onlymandatoryThermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.220ColumnoaLaser6TecRelHiHiread-onlymandatoryThermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%.
1.3.6.1.4.1.7501.1.2.116.5.1.1.221ColumnoaLaser6TemperatureLoLoread-onlymandatoryTemperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.222ColumnoaLaser6TemperatureLoread-onlymandatoryTemperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.223ColumnoaLaser6TemperatureValueread-onlymandatoryTemperature of laser no.1 in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.224ColumnoaLaser6TemperatureHiread-onlymandatoryTemperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.225ColumnoaLaser6TemperatureHiHiread-onlymandatoryTemperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees.
1.3.6.1.4.1.7501.1.2.116.5.1.1.226ColumnoaLaser6VoltageLoLoread-onlyoptionalThe supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.227ColumnoaLaser6VoltageLoread-onlyoptionalThe supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.228ColumnoaLaser6VoltageValueread-onlyoptionalThe supply voltage of laser no.1 in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.229ColumnoaLaser6VoltageHiread-onlyoptionalThe supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.5.1.1.230ColumnoaLaser6VoltageHiHiread-onlyoptionalThe supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts.
1.3.6.1.4.1.7501.1.2.116.6NodeoaDisplay
1.3.6.1.4.1.7501.1.2.116.6.1TableoaDisplayTablenot-accessiblemandatory
1.3.6.1.4.1.7501.1.2.116.6.1.1RowoaDisplayEntrynot-accessiblemandatory
1.3.6.1.4.1.7501.1.2.116.6.1.1.1ColumnoaDisplayNumberOfLasersread-onlymandatoryThe number of lasers used by this optical amplifier
1.3.6.1.4.1.7501.1.2.116.6.1.1.2ColumnoaDisplayNumberOfInternalVoltagesread-onlyoptionalThe number of internal voltages monitored by this optical amplifier
1.3.6.1.4.1.7501.1.2.116.6.1.1.3ColumnoaDisplayExtIOSupportedread-onlymandatoryReturn 'true(1)' if external I/O feature is supported by the device.
1.3.6.1.4.1.7501.1.2.116.6.1.1.4ColumnoaDisplaySbsSupportedread-onlymandatoryReturn 'true(1)' if SBS feature is supported by the device.
1.3.6.1.4.1.7501.1.2.116.6.1.1.5ColumnoaDisplayReturnLossSupportedread-onlymandatoryReturn 'true(1)' if ReturnLoss feature is supported by the device.
1.3.6.1.4.1.7501.1.2.116.6.1.1.6ColumnoaDisplaySbsEvaluatedThresholdread-onlymandatoryThe evaluated SBS output power or gain threshold in 0.1 dB(m) units. Not supported by all optical amplifiers
1.3.6.1.4.1.7501.1.2.116.6.1.1.7ColumnoaDisplaySbsLastEvaluationStateread-onlymandatoryThe result of last SBS threshold evaluation process. Returns 'evaluationNotSupported(1)' if SBS threshold evaluation is not supported by this optical amplifier
1.3.6.1.4.1.7501.1.2.116.6.1.1.8ColumnoaDisplaySbsLastEvaluationTimeread-onlymandatoryThe time of last successfull SBS threshold evaluation process. Not supported by all optical amplifiers
1.3.6.1.4.1.7501.1.2.116.6.1.1.9ColumnoaDisplayOutputPwrOrGainNominalread-onlymandatoryThe nominal value of output power (or gain) in 0.1 dB(m) units. See oaConfigRegulationMode variable too
1.3.6.1.4.1.7501.1.2.116.6.1.1.10ColumnoaDisplayOutputPwrOrGainAdjustedread-onlymandatoryThe adjusted desired value of output power (or gain) in 0.1 dB(m) units. See oaConfigRegulationMode variable too
1.3.6.1.4.1.7501.1.2.116.6.1.1.11ColumnoaDisplayInputVoltageNominalread-onlyoptionalThe nominal value of input voltage in 0.1 V units.
1.3.6.1.4.1.7501.1.2.116.6.1.1.12ColumnoaDisplayInternalVoltage1Nominalread-onlyoptionalThe nominal value of internal voltage no. 1 in 0.1 V units.
1.3.6.1.4.1.7501.1.2.116.6.1.1.13ColumnoaDisplayInternalVoltage2Nominalread-onlyoptionalThe nominal value of internal voltage no. 2 in 0.1 V units.
1.3.6.1.4.1.7501.1.2.116.6.1.1.14ColumnoaDisplayInternalVoltage3Nominalread-onlyoptionalThe nominal value of internal voltage no. 3 in 0.1 V units.
1.3.6.1.4.1.7501.1.2.116.6.1.1.20ColumnoaDisplayLaser1VoltageNominalread-onlyoptionalThe nominal supply voltage of laser no.1 in 0.1 V units.
1.3.6.1.4.1.7501.1.2.116.6.1.1.21ColumnoaDisplayLaser2VoltageNominalread-onlyoptionalThe nominal supply voltage of laser no.2 in 0.1 V units.
1.3.6.1.4.1.7501.1.2.116.6.1.1.22ColumnoaDisplayLaser3VoltageNominalread-onlyoptionalThe nominal supply voltage of laser no.3 in 0.1 V units.
1.3.6.1.4.1.7501.1.2.116.6.1.1.23ColumnoaDisplayLaser4VoltageNominalread-onlyoptionalThe nominal supply voltage of laser no.4 in 0.1 V units.
1.3.6.1.4.1.7501.1.2.116.6.1.1.24ColumnoaDisplayLaser5VoltageNominalread-onlyoptionalThe nominal supply voltage of laser no.5 in 0.1 V units.
1.3.6.1.4.1.7501.1.2.116.6.1.1.25ColumnoaDisplayLaser6VoltageNominalread-onlyoptionalThe nominal supply voltage of laser no.6 in 0.1 V units.
1.3.6.1.4.1.7501.1.2.116.6.1.1.30ColumnoaDisplayLaser1PumpPowerRelread-onlymandatoryThe pump power of laser no.1 in steps of 0.1%
1.3.6.1.4.1.7501.1.2.116.6.1.1.31ColumnoaDisplayLaser2PumpPowerRelread-onlymandatoryThe pump power of laser no.2 in steps of 0.1%
1.3.6.1.4.1.7501.1.2.116.6.1.1.32ColumnoaDisplayLaser3PumpPowerRelread-onlymandatoryThe pump power of laser no.3 in steps of 0.1%
1.3.6.1.4.1.7501.1.2.116.6.1.1.33ColumnoaDisplayLaser4PumpPowerRelread-onlymandatoryThe pump power of laser no.4 in steps of 0.1%
1.3.6.1.4.1.7501.1.2.116.6.1.1.34ColumnoaDisplayLaser5PumpPowerRelread-onlymandatoryThe pump power of laser no.5 in steps of 0.1%
1.3.6.1.4.1.7501.1.2.116.6.1.1.35ColumnoaDisplayLaser6PumpPowerRelread-onlymandatoryThe pump power of laser no.6 in steps of 0.1%
1.3.6.1.4.1.7501.1.2.116.6.1.1.40ColumnoaDisplayLaser1FeaturesSupportedread-onlymandatoryThe features supported by laser no.1 A bitfield containing the features supplied by this laser. Note that laserCurrent is always supplied.
1.3.6.1.4.1.7501.1.2.116.6.1.1.41ColumnoaDisplayLaser2FeaturesSupportedread-onlymandatoryThe features supported by laser no.2
1.3.6.1.4.1.7501.1.2.116.6.1.1.42ColumnoaDisplayLaser3FeaturesSupportedread-onlymandatoryThe features supported by laser no.3
1.3.6.1.4.1.7501.1.2.116.6.1.1.43ColumnoaDisplayLaser4FeaturesSupportedread-onlymandatoryThe features supported by laser no.4
1.3.6.1.4.1.7501.1.2.116.6.1.1.44ColumnoaDisplayLaser5FeaturesSupportedread-onlymandatoryThe features supported by laser no.5
1.3.6.1.4.1.7501.1.2.116.6.1.1.45ColumnoaDisplayLaser6FeaturesSupportedread-onlymandatoryThe features supported by laser no.6
1.3.6.1.4.1.7501.1.2.116.6.1.1.50ColumnoaDisplayAmplifierIsRamanTyperead-onlymandatoryReturns true(1) if this amplifier is of RAMAN type
Type Definitions
NameSyntaxStatusDescription
ExtIOmaskINTEGER { maskAlarmsOnly(1), maskAlarmsAndWarnings(2), maskSpecial(3) }
ExtIOmodeINTEGER { modeActiveLowOutput(1), modeActiveHighOutput(2), modeRedundantMasterIrreversible(3), modeRedundantMasterFallback(4), modeRedundantSlave(5) }
LaserFeaturesINTEGER { lasNonExistent(0), lasCurrent(1), lasCurrentLasTec(3), lasCurrentLasTemperature(5), lasCurrentLasTecLasTemperature(7), lasCurrentLasVoltage(9), lasCurrentLasTecLasVoltage(11), lasCurrentLasTemperatureLasVoltage(13), lasCurrentLasTecLasTemperatureLasVoltage(15), lasCurrentLasPumpPower(17), lasCurrentLasTecLasPumpPower(19), lasCurrentLasTemperatureLasPumpPower(21), lasCurrentLasTecLasTemperatureLasPumpPower(23), lasCurrentLasVoltageLasPumpPower(25), lasCurrentLasTecLasVoltageLasPumpPower(27), lasCurrentLasTemperatureLasVoltageLasPumpPower(29), lasCurrentLasTecLasTemperatureLasVoltageLasPumpPower(31) }
NESlotWriteValueINTEGER (-1..99)
RegulationModeINTEGER { regModeConstantOutputPower(1), regModeConstantGain(2) }
SbsEvaluationModeINTEGER { evalModeDefault(1), evalModeFullScan(2) }
SbsEvaluationStateINTEGER { evaluationNotSupported(1), evaluationDone(2), evaluationInProgress(3), evaluationFailed(4) }