BSC2780-OPT-MIB
50 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter enterprises |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.449 | Nodecodex | |||
| 1.3.6.1.4.1.449.2 | NodecdxProductSpecific | |||
| 1.3.6.1.4.1.449.2.1 | Nodecdx6500 | |||
| 1.3.6.1.4.1.449.2.1.2 | Nodecdx6500Configuration | |||
| 1.3.6.1.4.1.449.2.1.2.1 | Nodecdx6500CfgProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1 | Nodecdx6500PCTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1.11 | Tablecdx6500PPCTBSC2780Table | not-accessible | mandatory | A table of BSC2780 Port configuration entries. |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1 | Rowcdx6500bsc2780PortConfigEntry | not-accessible | mandatory | A BSC2780 Configuration Table entry. Each entry contains the configuration parameters for a single BSC2780 port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.1 | Columncdx6500bsc2780PortNumber | read-only | mandatory | The BSC2780 port number described by this entry. |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.2 | Columncdx6500bsc2780ClockSource | read-only | mandatory | int - internal clock source. ext - external clock source. newvalInt - same functionality as 'int', new enumeration introduced for RFC1155 compatibility. |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.3 | Columncdx6500bsc2780ClockSpeed | read-only | mandatory | This is the speed of the port in bits per second, when using internal clocking. |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.4 | Columncdx6500bsc2780Contention | read-only | mandatory | Indicates whether Half Duplex (hdx) or Full Duplex (fdx) modem signals are being generated. Full Duplex indicates communication is occuring in both directions … |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.5 | Columncdx6500bsc2780ErrThreshCount | read-only | mandatory | Indicates number of consecutive errors that can occur before a device is considered down. |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.6 | Columncdx6500bsc2780DisConnOnError | read-only | mandatory | Specifies whether a session should be disconnected if a control unit has not responded once the Error Threshold Count has been exceeded. newvalNo : same functi… |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.7 | Columncdx6500bsc2780ConnType | read-only | mandatory | Specify the control signal handshake required for a connection to be made to this port: simp - simple, no control signals required v25b - port emulates a dial … |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.8 | Columncdx6500bsc2780InterBuffTimeout | read-only | mandatory | Specifies the maximum amount of time in seconds the PAD will wait for the end of a multi-packet message from the network. If this time limit is exceeded, the P… |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.9 | Columncdx6500bsc2780PortSubAddr | read-only | mandatory | 0 - 3 Decimal digits Calls addressed to this node and with this subaddress will be routed to this port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.10 | Columncdx6500bsc2780ReConnRetry | read-only | mandatory | Number of times connection will be reattempted after a network induced disconnect. |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.11 | Columncdx6500bsc2780AutocallMnemonic | read-only | mandatory | This mnemonic name is used if this device is configured as a call originator. |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.12 | Columncdx6500bsc2780RestrictConnDest | read-only | mandatory | All calls originating from this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example,… |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.13 | Columncdx6500bsc2780BillRec | read-only | mandatory | This controls whether billing (accounting) records will be created for calls on this port. off - billing (accounting) records will not be created. on - billing… |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.14 | Columncdx6500bsc2780DSRfollowSVC | read-only | mandatory | Specify whether DSR on/off required with circuit on/off. This is only available with connection type SIMP or RS366. yes = DSR will be ON only while a call is i… |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.15 | Columncdx6500bsc2780DSRholdTime | read-only | mandatory | Time in steps of 50 ms to drop DSR signal after the circuit is disconnected in DSR-Follow-SVC mode. This timer value is ignored otherwise. |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.16 | Columncdx6500bsc2780PortOption | read-only | deprecated | This object has been deprecated, It is replaced by cdx6500bsc2780PortOptString. |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.17 | Columncdx6500bsc2780TrafficPriority | read-only | optional | This is the traffic priority of the 2780 device; low, medium, high, and expedite. newvalLowPriority : same functionality as 'lowPriority', new enumeration intr… |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.18 | Columncdx6500bsc2780PortOptString | read-only | mandatory | This is the new object for cdx6500bsc2780PortOption. Specify any of the following port control options: NONE - no option specified. EOT - EOT will be dropped w… |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.19 | Columncdx6500bsc2780IdleDiscTimer | read-only | mandatory | The call on the port will be cleared when this timer is expired. This timer will be started when it received an EOT. 0 - Timer Disabled. 1 to 60 - Timer Value … |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.20 | Columncdx6500bsc2780ElectricalInterfaceType | read-only | mandatory | Specify the Electrical Interface Type: V.24 - V.24 Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Elect… |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.21 | Columncdx6500bsc2780V24ElectricalInterfaceOption | read-only | mandatory | Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.22 | Columncdx6500bsc2780HighSpeedElectricalInterfaceOption | read-only | mandatory | Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable |
| 1.3.6.1.4.1.449.2.1.2.1.1.11.1.23 | Columncdx6500bsc2780RemoteType | read-only | mandatory | Specify the remote type: T2780 - remote is BSC2780 PAD SNAINT - remote is SNA/2780 Interactive |
| 1.3.6.1.4.1.449.2.1.3 | Nodecdx6500Statistics | |||
| 1.3.6.1.4.1.449.2.1.3.1 | Nodecdx6500StatProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1 | Nodecdx6500PSTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1.11 | Tablecdx6500PPSTBSC2780Table | not-accessible | mandatory | A table of BSC2780 port statistics entries. |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1 | Rowcdx6500bsc2780PortStatEntry | not-accessible | mandatory | A BSC2780 Port Statistic Table entry. Each entry contains the statistics for a single BSC2780 port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.1 | Columncdx6500bsc2780StatPortNumber | read-only | mandatory | The BSC2780 port number described by this entry. |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.2 | Columncdx6500bsc2780PortStatus | read-only | mandatory | Port Status indicates whether or not the port is switched on and is ready for operation. This value may be one of : up - Port is up and running. down - port is… |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.3 | Columncdx6500bsc2780PortState | read-only | mandatory | Port State indicates what the port is actually in the process of doing. This value may be one of : DISC - No call is currently connected to the specified port.… |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.4 | Columncdx6500bsc2780PortSpeed | read-only | mandatory | This is the speed of the port if clock is internal. If clock is external, this is the detected clock speed. If Port Speed is 0, clock is external, but clocking… |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.5 | Columncdx6500bsc2780PortUtilIn | read-only | mandatory | Percentage of Port input bandwidth in use. |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.6 | Columncdx6500bsc2780PortUtilOut | read-only | mandatory | Percentage of Port output bandwidth in use. |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.7 | Columncdx6500bsc2780InMsgs | read-only | mandatory | Number of message received since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.8 | Columncdx6500bsc2780OutMsgs | read-only | mandatory | Number of message sent since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.9 | Columncdx6500bsc2780InChars | read-only | mandatory | Number of characters received since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.10 | Columncdx6500bsc2780OutChars | read-only | mandatory | Number of characters sent since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.11 | Columncdx6500bsc2780CharRateIn | read-only | mandatory | Number of characters received per second. |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.12 | Columncdx6500bsc2780CharRateOut | read-only | mandatory | Number of characters sent per second. |
| 1.3.6.1.4.1.449.2.1.3.1.1.11.1.13 | Columncdx6500bsc2780CrcBccErrs | read-only | mandatory | Number of CRC errors since last node, port, or statistics reset. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DisplayString | OCTET STRING |