BSC3270-OPT-MIB
80 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.449 | Nodecodex | |||
| 1.3.6.1.4.1.449.2 | NodecdxProductSpecific | |||
| 1.3.6.1.4.1.449.2.1 | Nodecdx6500 | |||
| 1.3.6.1.4.1.449.2.1.2 | Nodecdx6500Configuration | |||
| 1.3.6.1.4.1.449.2.1.2.1 | Nodecdx6500CfgProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1 | Nodecdx6500PCTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1.10 | Tablecdx6500PPCTBSC3270PortTable | not-accessible | mandatory | A table of BSC3270 Port configuration entries. |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1 | Rowcdx6500PPCTBSC3270PortEntry | not-accessible | mandatory | A BSC3270 Port Configuration Table entry. Each entry contains the configuration parameters for a single BSC3270 port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.1 | Columncdx6500BSC3270PortNumber | read-only | mandatory | The BSC3270 port number described by this entry. |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.2 | Columncdx6500BSC3270PADType | read-only | mandatory | Indicates whether the port is functioning as a Terminal PAD (tpad) or a Host PAD (hpad). newvalTpad - same functionality as 'tpad', new enumeration introduced … |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.3 | Columncdx6500BSC3270ClockSource | read-only | mandatory | int - internal clock source. ext - external clock source. newvalInt - same functionality as 'int', new enumeration introduced for RFC1155 compatibility. |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.4 | Columncdx6500BSC3270ClockSpeed | read-only | mandatory | This is the speed of the port in bits per second, when using internal clocking. |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.5 | Columncdx6500BSC3270Contention | read-only | mandatory | Indicates whether Half Duplex (hdx) or Full Duplex (fdx) modem signals are being generated. Full Duplex indicates communication is occuring in both directions … |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.6 | Columncdx6500BSC3270NumDevices | read-only | mandatory | Specifies the number of physical devices on this line. |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.7 | Columncdx6500BSC3270ServTimer | read-only | mandatory | The Service Timer specifies the interval of time in seconds between periodic servicing. Such servicing includes intervals between the time the PAD will attempt… |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.8 | Columncdx6500BSC3270ErrThreshCount | read-only | mandatory | Indicates number of consecutive errors that can occur before a device is considered down. |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.9 | Columncdx6500BSC3270ResponseTimeout | read-only | mandatory | Specifies the amount of time in seconds that the TPAD will wait for a response from a device before it attempts to re-poll the non-responding device. The TPAD … |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.10 | Columncdx6500BSC3270HostPADTimeout | read-only | mandatory | Specifies the amount of time in seconds that the HPAD will wait for the host to poll a device. If the time limit is exceeded, the HPAD will consider the device… |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.11 | Columncdx6500BSC3270InterBuffTimeout | read-only | mandatory | Specifies the maximum amount of time in seconds the PAD will wait for the end of a multi-packet message from the network. If this time limit is exceeded, the P… |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.12 | Columncdx6500BSC3270IdleDevTimeout | read-only | mandatory | Specifies the amount of time in minutes that the TPAD will wait for user data from a device after an X.25 call has been established, before disconnecting the c… |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.13 | Columncdx6500BSC3270PrintDisconTimer | read-only | mandatory | Specifies the amount of time in seconds that an X.25 call to a Printer device is disconnected after a period of inactivity. |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.14 | Columncdx6500BSC3270SignonKey | read-only | mandatory | This parameter assignes a Function Key that will be used to generate a connection. This parameter is applicable to a TPAD port only. This parameter is not appl… |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.15 | Columncdx6500BSC3270DiscKey | read-only | mandatory | This parameter allows assignment of the Function Key needed to clear the current session. This parameter is applicable to a TPAD port only. This parameter is n… |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.16 | Columncdx6500BSC3270CharSet | read-only | mandatory | Indicates whether Terminal/Printer devices on this port support an ascii or ebcdic character set. newvalAscii : same functionality as 'ascii', new enumeration … |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.17 | Columncdx6500BSC3270PortSubAddr | read-only | mandatory | Calls addressed to this node and with this subaddress will be routed to this port. |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.18 | Columncdx6500BSC3270PortOptions | read-only | mandatory | Select options on this BSC3270 port as follows: NONE - no option specified CESS - Turn the polling cessation option ON. In the HPAD, a G-POLL will not be respo… |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.19 | Columncdx6500BSC3270RestrictConnDest | read-only | mandatory | All calls originating from this port will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example,… |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.20 | Columncdx6500bsc3270ElectricalInterfaceType | read-only | mandatory | Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 -… |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.21 | Columncdx6500bsc3270V24ElectricalInterfaceOption | read-only | mandatory | Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal |
| 1.3.6.1.4.1.449.2.1.2.1.1.10.1.22 | Columncdx6500bsc3270HighSpeedElectricalInterfaceOption | read-only | mandatory | Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable |
| 1.3.6.1.4.1.449.2.1.2.1.4 | Nodecdx6500PCTBSC3270DeviceGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.4.1 | Tablecdx6500PBCTBSC3270DevTable | not-accessible | mandatory | A table of BSC3270 device configuration entries. |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1 | Rowcdx6500PBCTBSC3270DevEntry | not-accessible | mandatory | A BSC3270 Device Configuration Table entry. Each entry contains the configuration parameters for a single BSC3270 device. |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.1 | Columncdx6500BSC3270DevPortNumber | read-only | mandatory | The BSC3270 port accessing this device. |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.2 | Columncdx6500BSC3270DevEntry | read-only | mandatory | The unique number for this specific port, 1 ... 32. |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.3 | Columncdx6500BSC3270BSCControlUnitAddr | read-only | mandatory | This is the Poll address of the Control Unit that supports this device. It consists of two hexadecimal digits. Valid ranges depend on device Character Set as f… |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.4 | Columncdx6500BSC3270BSCDevAddr | read-only | mandatory | This is the Poll/Select address of this device. It consists of two hexadecimal digits. Valid ranges depend on device Character Set as follows: EBCDIC: 40,C1,C2… |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.5 | Columncdx6500BSC3270DSPDevType | read-only | mandatory | term - device is a terminal. prin - device is a printer. newvalTerm - same functionality as 'term', new enumeration introduced for RFC1155 compatibility. |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.6 | Columncdx6500BSC3270DSPControl | read-only | mandatory | Specifies device call control. Values AUTO and FAST should not be simultaneously chosen: NONE - device will not be a call originator and will be enabled ORG - … |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.7 | Columncdx6500BSC3270DevControl | read-only | mandatory | Specifies device control parameters: NONE - no device control parameter set. GPOLL- disables specific polling of a device. The device will only be polled by ge… |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.8 | Columncdx6500BSC3270DSPDevCharacteristics | read-only | mandatory | NONE - no option XPAR - device supports transparency COLOR - device supports color PRINa - printer is attached to a terminal device Any combination of above sp… |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.9 | Columncdx6500BSC3270DSPDevFormatSize | read-only | mandatory | Specifies maximum size of the terminal or printer message. newvalFormat480 - same functionality as 'format480', new enumeration introduced for RFC1155 compatib… |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.10 | Columncdx6500BSC3270DSPCharSetCapability | read-only | mandatory | Indicates device capability: NONE - no indication of capability APL - APL capability TEXT - Text capability Any combination of above specified by summing (eg. … |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.11 | Columncdx6500BSC3270ConnReqMode | read-only | mandatory | Specifies which DSP Connection Request Mode (CRM) to use. There are three modes of connection as follow: 1 - fixed class CRM, connects a call to the device on … |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.12 | Columncdx6500BSC3270DestControlUnitAddr | read-only | mandatory | Specifies control unit address on remote PAD. Used with Connection Request Mode = 2 or 3. |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.13 | Columncdx6500BSC3270DestDevAddr | read-only | mandatory | Specifies device address on remote PAD. Used with Connection Request Mode = 2 or 3. |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.14 | Columncdx6500BSC3270AutocallMnemonic | read-only | mandatory | This mnemonic name is used if this device is configured for AUTO or FAST calling. |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.15 | Columncdx6500BSC3270DSPApplicationIdent | read-only | mandatory | Specifies the target application to which this device would be connected. This should match with the application ID of the Host DSP device. |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.16 | Columncdx6500BSC3270DSPCompatibility | read-only | mandatory | Select yes if the device connects to a DSP host or if it connects to a Codex 6507/6525 node with 2.13 or higher software revision. Select no if the device conn… |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.17 | Columncdx6500BSC3270BillRec | read-only | mandatory | This controls whether billing (accounting) records will be created for calls on this Device. newvalOff - same functionality as 'off', new enumeration introduce… |
| 1.3.6.1.4.1.449.2.1.2.1.4.1.1.18 | Columncdx6500BSC3270TrafficPriority | read-only | optional | This is the traffic priority of the 3270 device; low, medium, high, or expedite. newvalLowPriority - same functionality as 'lowpriority', new enumeration intro… |
| 1.3.6.1.4.1.449.2.1.3 | Nodecdx6500Statistics | |||
| 1.3.6.1.4.1.449.2.1.3.1 | Nodecdx6500StatProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1 | Nodecdx6500PSTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1.10 | Tablecdx6500PPSTBSC3270PortTable | not-accessible | mandatory | A table of BSC3270 port statistics entries. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1 | Rowcdx6500PPSTBSC3270PortEntry | not-accessible | mandatory | A BSC3270 Port Statistic Table entry. Each entry contains the statistics for a single BSC3270 port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.1 | Columncdx6500BSC3270StatPortNumber | read-only | mandatory | The BSC3270 port number described by this entry. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.2 | Columncdx6500BSC3270PortStatus | read-only | mandatory | Port Status indicates whether or not the port is switched on and is ready for operation. This value may be one of : up - Port is up and running down - port is … |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.3 | Columncdx6500BSC3270PortState | read-only | mandatory | Port State indicates what the port is actually in the process of doing. This value may be one of : INACTIVE - H/TPAD port inactive entered during boot WTPOLSER… |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.4 | Columncdx6500BSC3270PortSpeed | read-only | mandatory | This is the speed of the port if clock is internal. If clock is external, this is the detected clock speed. If Port Speed is 0, clock is external, but clocking… |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.5 | Columncdx6500BSC3270PortUtilIn | read-only | mandatory | Pertcentage of Port input bandwidth in use. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.6 | Columncdx6500BSC3270PortUtilOut | read-only | mandatory | Pertcentage of Port output bandwidth in use. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.7 | Columncdx6500BSC3270InMsgs | read-only | mandatory | Number of message received since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.8 | Columncdx6500BSC3270OutMsgs | read-only | mandatory | Number of message sent since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.9 | Columncdx6500BSC3270InChars | read-only | mandatory | Number of characters received since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.10 | Columncdx6500BSC3270OutChars | read-only | mandatory | Number of characters sent since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.11 | Columncdx6500BSC3270CharRateIn | read-only | mandatory | Number of characters received per second. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.12 | Columncdx6500BSC3270CharRateOut | read-only | mandatory | Number of characters sent per second. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.13 | Columncdx6500BSC3270CrcBccErrs | read-only | mandatory | Number of CRC errors since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.14 | Columncdx6500BSC3270InPosAcks | read-only | mandatory | Number of ACKs received since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.15 | Columncdx6500BSC3270OutPosAcks | read-only | mandatory | Number of ACKs sent since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.16 | Columncdx6500BSC3270InNegAcks | read-only | mandatory | Number of NAKs received since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.17 | Columncdx6500BSC3270OutNegAcks | read-only | mandatory | Number of NAKs sent since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.18 | Columncdx6500BSC3270MsgRateIn | read-only | mandatory | Number of messages received per second. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.19 | Columncdx6500BSC3270MsgRateOut | read-only | mandatory | Number of messages sent per second. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.20 | Columncdx6500BSC3270InEnq | read-only | mandatory | Number of ENQs received since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.21 | Columncdx6500BSC3270OutEnq | read-only | mandatory | Number of ENQs sent since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.10.1.22 | Columncdx6500BSC3270NumRetran | read-only | mandatory | Number of messages retransmitted since last node, port, or statistics reset. |
| 1.3.6.1.4.1.449.2.1.4 | Nodecdx6500Controls |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| DisplayString | OCTET STRING |