CDM-570
155 objects
Module Identity for both CDM-570 L-Band and IF-Band Satellite Modems.
Imported Objects
| ComtechEFData | comtechEFData |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DisplayString MacAddress |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.6247.24 | Identitycdm570 | Module Identity for both CDM-570 L-Band and IF-Band Satellite Modems. | ||
| 1.3.6.1.4.1.6247.24.1 | Nodecdm570Objects | |||
| 1.3.6.1.4.1.6247.24.1.1 | Nodecdm570System | |||
| 1.3.6.1.4.1.6247.24.1.1.1 | Nodecdm570SystemInfo | |||
| 1.3.6.1.4.1.6247.24.1.1.1.1 | Scalarcdm570SerialNumber | read-only | current | Used to query the unit 9-digit serial number. Unit returns its S/N in the form xxxxxxxxx. |
| 1.3.6.1.4.1.6247.24.1.1.1.2 | Scalarcdm570Temperature | read-only | current | Unit returns the value of the internal temperature, in degrees Celsius. |
| 1.3.6.1.4.1.6247.24.1.1.2 | Nodecdm570SystemEquipmentID | |||
| 1.3.6.1.4.1.6247.24.1.1.2.1 | Scalarcdm570TurboOption | read-only | current | Turbo option, where: 0 = None 1 = Turbo 2 = TPC/LDPC |
| 1.3.6.1.4.1.6247.24.1.1.2.2 | Scalarcdm570ModelNumber | read-only | current | Modem model number. |
| 1.3.6.1.4.1.6247.24.1.1.2.3 | Scalarcdm570DataRateOption | read-only | current | Data rate option, where: 0 = Base (512 kbps) 1 = Up to 2048 kbps 2 = Up to 5000 kbps 3 = Up to 9980 kbps |
| 1.3.6.1.4.1.6247.24.1.1.2.4 | Scalarcdm570HigherOrderModulation | read-only | current | Higer order modulation, where: 0 = None 1 = 8-PSK/8-QAM 2 = 16-QAM 3 = 8-PSK/8-QAM and 16-QAM |
| 1.3.6.1.4.1.6247.24.1.1.2.5 | Scalarcdm570IPOption | read-only | current | IP Controller card, where: 0 = None 1 = Installed |
| 1.3.6.1.4.1.6247.24.1.1.2.6 | Scalarcdm570RSCodecOption | read-only | current | RS Codec Option, where: 0 = None 1 = Installed |
| 1.3.6.1.4.1.6247.24.1.1.3 | Nodecdm570SystemFirmware | |||
| 1.3.6.1.4.1.6247.24.1.1.3.1 | Scalarcdm570FirmwareRevision | read-only | current | Unit returns the value of the internal software revision installed in the unit, in the form of: Boot: XXXXXX Bulk1: YYYYYY Bulk2: ZZZZZZ, where: XXXXXX = softw… |
| 1.3.6.1.4.1.6247.24.1.2 | Nodecdm570Config | |||
| 1.3.6.1.4.1.6247.24.1.2.1 | Nodecdm570EthernetRemoteControl | |||
| 1.3.6.1.4.1.6247.24.1.2.1.1 | Scalarcdm570IpAddress | read-write | current | The IP address for the 10/100 BaseTx Ethernet management port. |
| 1.3.6.1.4.1.6247.24.1.2.1.2 | Scalarcdm570IpSubnetMask | read-write | current | The network prefix length for the 10/100 BaseTx Ethernet management port. |
| 1.3.6.1.4.1.6247.24.1.2.1.3 | Scalarcdm570DefaultGateway | read-write | current | The IP address of the default gateway. |
| 1.3.6.1.4.1.6247.24.1.2.1.4 | Scalarcdm570MacAddress | read-only | current | The MAC address of the Ethernet interface. |
| 1.3.6.1.4.1.6247.24.1.2.1.5 | Nodecdm570AccessLists | |||
| 1.3.6.1.4.1.6247.24.1.2.1.5.1 | Scalarcdm570AccessListEnforcement | read-write | current | Enable or disable enforcement of the the access list. Note: Be sure that you have added the SNMP browser's/manager's IP Address to the access list before enabl… |
| 1.3.6.1.4.1.6247.24.1.2.1.5.2 | Tablecdm570AccessListTable | not-accessible | current | The table that holds the access list. |
| 1.3.6.1.4.1.6247.24.1.2.1.5.2.1 | Rowcdm570AccessListEntry | not-accessible | current | The entry for the access list table. |
| 1.3.6.1.4.1.6247.24.1.2.1.5.2.1.1 | Columncdm570AccessListIndex | read-only | current | The index for the access list from 1..4. |
| 1.3.6.1.4.1.6247.24.1.2.1.5.2.1.2 | Columncdm570AccessIPAddress | read-write | current | The IP addresses that can access the unit. The value of 0.0.0.0 means not defined. |
| 1.3.6.1.4.1.6247.24.1.2.1.5.2.1.3 | Columncdm570AccessSubnetMaskLength | read-write | current | The subnet mask length of the IP address for the access list. Subnet mask can be from 8..32. The value of 0 means not defined. |
| 1.3.6.1.4.1.6247.24.1.2.1.6 | Nodecdm570SNMP | |||
| 1.3.6.1.4.1.6247.24.1.2.1.6.1 | Scalarcdm570SNMPTrapDestinationIpAddress1 | read-write | current | The IP address were SNMP notifications (traps) are to be sent. This IP address should correspond to a SNMP manager or browser. |
| 1.3.6.1.4.1.6247.24.1.2.1.6.2 | Scalarcdm570SNMPTrapDestinationIpAddress2 | read-write | current | The IP address were SNMP notifications (traps) are to be sent. This IP address should correspond to a SNMP manager or browser. |
| 1.3.6.1.4.1.6247.24.1.2.1.6.3 | Scalarcdm570SNMPTrapCommunity | read-write | current | The community that will be included in SNMP notifications (traps) that are sent from unit. |
| 1.3.6.1.4.1.6247.24.1.2.1.6.4 | Scalarcdm570SNMPTrapVersion | read-write | current | The SNMP version that will be used when sending traps from the unit. SNMPv1 will send V1 traps. SNMPv2 will send V2 notifications. |
| 1.3.6.1.4.1.6247.24.1.2.2 | Nodecdm570Tx | |||
| 1.3.6.1.4.1.6247.24.1.2.2.1 | Scalarcdm570TxFrequency | read-write | current | Transmit frequency for both CDM-570L (L-Band) modem and CDM-570 (IF-band) modems. L-Band is 950 MHz to 1950 MHz. IF-Band is 50 MHz to 90 MHz and 100 MHz to 180… |
| 1.3.6.1.4.1.6247.24.1.2.2.2 | Scalarcdm570TxDataRate | read-write | current | Tx data rate in bps (Varies based on chart below.) Units = bps Resolution = 1 bps FEC Type Modulation Code Rate Data Rate High Rate None BPSK Uncoded 4.8 kbps … |
| 1.3.6.1.4.1.6247.24.1.2.2.3 | Scalarcdm570TxFECCodeRate | read-write | current | Transmit code rate, where 0 = Rate 5/16 (Turbo only) 1 = Rate 22/44 (Turbo only) 2 = Rate 1/2 3 = Rate 2/3 (8-PSK TCM or 16-QAM only) 4 = Rate 3/4 5 = Rate 7/8… |
| 1.3.6.1.4.1.6247.24.1.2.2.4 | Scalarcdm570TxModType | read-write | current | Transmit modulation type, where: 0 = BPSK 1 = QPSK 2 = OQPSK 3 = 8-PSK 4 = 16-QAM (Turbo or Viterbi + RS only) 5 = 8-QAM Depending on FEC type, not all of thes… |
| 1.3.6.1.4.1.6247.24.1.2.2.5 | Scalarcdm570TxFECType | read-write | current | Transmit FEC type where: 0 = Uncoded 1 = Viterbi 2 = Viterbit + Reed-Solomon 5 = TCM + Reed-Solomon (Code Rate = 2/3) 6 = Turbo 7 = TPC/LDPC Depending on hardw… |
| 1.3.6.1.4.1.6247.24.1.2.2.6 | Scalarcdm570TxSpectrumInvert | read-write | current | Transmit spectrum invert selection, where: 0 = Normal 1 = Transmit spectrum inverted |
| 1.3.6.1.4.1.6247.24.1.2.2.7 | Scalarcdm570TxDataInvert | read-write | current | Invert transmit data, where: 0 = Normal 1 = Inverted |
| 1.3.6.1.4.1.6247.24.1.2.2.8 | Scalarcdm570TxClockSource | read-write | current | Transmit clock source, where: 0 = Internal 1 = Tx Terrestrial 2 = Loop-Timed |
| 1.3.6.1.4.1.6247.24.1.2.2.9 | Scalarcdm570TxScrambler | read-write | current | Transmit scrambler state, where: 0 = Off 1 = On (Default scrambler type) 2 = On = IESS-315 (Turbo only) |
| 1.3.6.1.4.1.6247.24.1.2.2.10 | Scalarcdm570TxPowerLevel | read-write | current | Transmit output power level for both CDM-570L (L-Band) modem and CDM-570 (IF-band) modem. CDM-570L power level is between -40 and 0 dBm. CDM-570 power level is… |
| 1.3.6.1.4.1.6247.24.1.2.2.11 | Scalarcdm570TxCarrierState | read-write | current | Transmit carrier state, where: 0 = Off 1 = On 2 = RTI (Receive/Transmit Inhibit) The following values are query only: 3 = External Control (read only) 4 = BUC … |
| 1.3.6.1.4.1.6247.24.1.2.2.12 | Scalarcdm570TxSymbolRate | read-only | current | Tx symbol rate in symbols per second (sps) Units = symbols per second (sps) Resolution = 1 sps |
| 1.3.6.1.4.1.6247.24.1.2.3 | Nodecdm570Rx | |||
| 1.3.6.1.4.1.6247.24.1.2.3.1 | Scalarcdm570RxFrequency | read-write | current | Receive frequency for both CDM-570L (L-Band) modem and CDM-570 (IF-band) modems. L-Band is 950 MHz to 1950 MHz. IF-Band is 50 MHz to 90 MHz and 100 MHz to 180 … |
| 1.3.6.1.4.1.6247.24.1.2.3.2 | Scalarcdm570RxDataRate | read-write | current | Rx data rate in bps (Varies based on chart below.) Units = bps Resolution = 1 bps FEC Type Modulation Code Rate Data Rate High Rate None BPSK Uncoded 4.8 kbps … |
| 1.3.6.1.4.1.6247.24.1.2.3.3 | Scalarcdm570RxFECCodeRate | read-write | current | Rx code rate, where 0 = Rate 5/16 (Turbo only) 1 = Rate 22/44 (Turbo only) 2 = Rate 1/2 3 = Rate 2/3 (8-PSK TCM or 16-QAM only) 4 = Rate 3/4 5 = Rate 7/8 6 = R… |
| 1.3.6.1.4.1.6247.24.1.2.3.4 | Scalarcdm570RxDemodType | read-write | current | Rx demodulation type, where: 0 = BPSK 1 = QPSK 2 = OQPSK 3 = 8-PSK 4 = 16-QAM (Turbo or Viterbi + RS only) 5 = 8-QAM Depending on FEC type, not all of these se… |
| 1.3.6.1.4.1.6247.24.1.2.3.5 | Scalarcdm570RxFECType | read-write | current | Rx FEC type where: 0 = Uncoded 1 = Viterbi 2 = Viterbit + Reed-Solomon 5 = TCM + Reed-Solomon (Code Rate = 2/3) 6 = Turbo 7 = TPC/LDPC Depending on hardware, n… |
| 1.3.6.1.4.1.6247.24.1.2.3.6 | Scalarcdm570RxEbNoAlarmPoint | read-write | current | Rx Eb/No alarm point in 0.1 dB, with a range between 0.1 dB and 16 dB. Units = 0.1 dB. Resolution = 0.1 dB. |
| 1.3.6.1.4.1.6247.24.1.2.3.7 | Scalarcdm570RxSpectrumInvert | read-write | current | Rx spectrum inversion, where: 0 = Normal 1 = Rx spectrum inverted |
| 1.3.6.1.4.1.6247.24.1.2.3.8 | Scalarcdm570RxDataInvert | read-write | current | Invert receive data, where: 0 = Normal 1 = Inverted |
| 1.3.6.1.4.1.6247.24.1.2.3.9 | Scalarcdm570RxBufferSize | read-write | current | Rx buffer size, where: 0 = Buffer disabled (Clock mode = Rx satellite) 1 = +/- 1024 bits 2 = +/- 2048 bits 3 = +/- 4096 bits 4 = +/- 8192 bits 5 = +/- 16384 bi… |
| 1.3.6.1.4.1.6247.24.1.2.3.10 | Scalarcdm570RxDescrambler | read-write | current | Rx descrambler state, where: 0 = Off 1 = On (default descrambler type) 2 = On - IESS-315 (Turbo only) |
| 1.3.6.1.4.1.6247.24.1.2.3.11 | Scalarcdm570RxDemodAcqSweepWidth | read-write | current | Rx +/- acquisition sweep range of demodulator, in KHz, ranging from: +/- 1 to +/- 32 KHz (rates < 625 ksym/second) or +/- 1 to 200 KHz (rates >= 625 ksym/secon… |
| 1.3.6.1.4.1.6247.24.1.2.3.12 | Scalarcdm570RxSymbolRate | read-only | current | Rx symbol rate in symbols per second (sps) Units = symbols per second (sps) Resolution = 1 sps |
| 1.3.6.1.4.1.6247.24.1.2.4 | Nodecdm570Frame | |||
| 1.3.6.1.4.1.6247.24.1.2.4.1 | Scalarcdm570FramingMode | read-write | current | Unit operating mode, where: 0 = Unframed 1 = EDMAC Framing 2 = EDMAC-2 Framing |
| 1.3.6.1.4.1.6247.24.1.2.4.2 | Nodecdm570EDMAC | |||
| 1.3.6.1.4.1.6247.24.1.2.4.2.1 | Scalarcdm570EDMACMode | read-write | current | EDMAC mode, where: 0 = EDMAC Idle 1 = EDMAC Master 2 = EDMAC Slave |
| 1.3.6.1.4.1.6247.24.1.2.4.2.2 | Scalarcdm570EDMACAddress | read-write | current | For a Master, the EDMA Address is the range of addresses of distant-end units (modems or transceivers) which this unit, as the Master, will forward messages fo… |
| 1.3.6.1.4.1.6247.24.1.2.4.3 | Nodecdm570AUPC | |||
| 1.3.6.1.4.1.6247.24.1.2.4.3.1 | Scalarcdm570AUPCEnable | read-write | current | AUPC mode enable/disable, where: 0 = Disable 1 = Enable Note: To enable AUPC, framing must FIRST be enabled. |
| 1.3.6.1.4.1.6247.24.1.2.4.3.2 | Scalarcdm570AUPCRemoteDemodTargetEbNo | read-write | current | Target Eb/No value for remote demod, from 0.0 to 14.9 dB. Units = 0.1 dB. |
| 1.3.6.1.4.1.6247.24.1.2.4.3.3 | Scalarcdm570AUPCTxPowerMaxIncrease | read-write | current | Max increase in Tx Power permitted, from 0 to 9 dB. Units = dB. |
| 1.3.6.1.4.1.6247.24.1.2.4.3.4 | Scalarcdm570AUPCActionOnMaxPower | read-write | current | Defines action on max. power condition, where: 0 = No action 1 = Generate Tx alarm |
| 1.3.6.1.4.1.6247.24.1.2.4.3.5 | Scalarcdm570AUPCActionOnRemoteDemodUnlock | read-write | current | Defines action on remote demod unlock, where: 0 = Go to nominal power 1 = Go to max power |
| 1.3.6.1.4.1.6247.24.1.2.5 | Nodecdm570Interface | |||
| 1.3.6.1.4.1.6247.24.1.2.5.1 | Scalarcdm570DataInterface | read-write | current | Terrestrial interface type, where: 0 = EIA-422/EIA-530 DCE 1 = V.35 DCE 2 = EIA-232 (sync) 3 = G.703 T1 AMI (forces Rx and Tx data rates to 1544 kbps) 4 = G.70… |
| 1.3.6.1.4.1.6247.24.1.2.5.2 | Nodecdm570RTSCTSOper | |||
| 1.3.6.1.4.1.6247.24.1.2.5.2.1 | Scalarcdm570RTS | read-write | current | Defines how RTS/CTS will operate at the main data interface, where: 0 = RTS/CTS Loop, No Action (RTS and CTS are looped, so that CTS echoes the state of RTS, b… |
| 1.3.6.1.4.1.6247.24.1.2.5.3 | Nodecdm570G703T1 | |||
| 1.3.6.1.4.1.6247.24.1.2.5.3.1 | Scalarcdm570T1LineBuildOut | read-write | current | Valid only for T1 interface, where: 0 = 0 - 133 feet 1 = 133 - 266 feet 2 = 266 - 399 feet 3 = 399 - 533 feet 4 = 533 - 655 feet |
| 1.3.6.1.4.1.6247.24.1.2.6 | Nodecdm570Reference | |||
| 1.3.6.1.4.1.6247.24.1.2.6.1 | Scalarcdm570ReferenceFrequency | read-write | current | External reference frequency, where: 0 = Internal 10 MHz 1 = External 1 MHz 2 = External 2 MHz 3 = External 5 MHz 4 = External 10 MHz 5 = External 20 MHz |
| 1.3.6.1.4.1.6247.24.1.2.7 | Nodecdm570AlarmMask | |||
| 1.3.6.1.4.1.6247.24.1.2.7.1 | Scalarcdm570AlarmMaskTxFIFO | read-write | current | Tx FIFO alarm mask, where: 0 = Unmasked 1 = Masked |
| 1.3.6.1.4.1.6247.24.1.2.7.2 | Scalarcdm570AlarmMaskG703BPV | read-write | current | G.703 BPV alarm mask, where: 0 = Unmasked 1 = Masked |
| 1.3.6.1.4.1.6247.24.1.2.7.3 | Scalarcdm570AlarmMaskTxAIS | read-write | current | Tx-AIS alarm mask, where: 0 = Unmasked 1 = Masked |
| 1.3.6.1.4.1.6247.24.1.2.7.4 | Scalarcdm570AlarmMaskRxAGC | read-write | current | Rx AGC alarm mask, where: 0 = Unmasked 1 = Masked |
| 1.3.6.1.4.1.6247.24.1.2.7.5 | Scalarcdm570AlarmMaskEbNoAlarm | read-write | current | Eb/No alarm mask, where: 0 = Unmasked 1 = Masked |
| 1.3.6.1.4.1.6247.24.1.2.7.6 | Scalarcdm570AlarmMaskRxAIS | read-write | current | Rx-AIS alarm mask, where: 0 = Unmasked 1 = Masked |
| 1.3.6.1.4.1.6247.24.1.2.7.7 | Scalarcdm570AlarmMaskBufferSlip | read-write | current | Buffer slip alarm mask, where: 0 = Unmasked 1 = Masked |
| 1.3.6.1.4.1.6247.24.1.2.7.8 | Scalarcdm570AlarmMaskExtReference | read-write | current | External reference alarm mask, where: 0 = Unmasked 1 = Masked |
| 1.3.6.1.4.1.6247.24.1.2.8 | Nodecdm570ODU | |||
| 1.3.6.1.4.1.6247.24.1.3 | Nodecdm570Monitor | |||
| 1.3.6.1.4.1.6247.24.1.3.1 | Nodecdm570Alarms | |||
| 1.3.6.1.4.1.6247.24.1.3.1.1 | Scalarcdm570UnitAlarms | read-only | current | Modem Unit Faults: Value Description of unit fault 0 No faults 1 +5 Volt power supply 2 +12 Volt power supply 3 -5 Volt power supply 4 +23 Volt power supply 5 … |
| 1.3.6.1.4.1.6247.24.1.3.1.2 | Scalarcdm570TxAlarms | read-only | current | Modem TX Traffic Faults: Value Description of Tx Traffic status 0 Tx traffic OK 1 No clock from terrestrial interface 3 Tx FIFO slip 5 Loss of External Referen… |
| 1.3.6.1.4.1.6247.24.1.3.1.3 | Scalarcdm570RxAlarms | read-only | current | Modem RX Traffic Faults Value Description of status parameter 0 Rx Traffic OK 1 Demodulator unlocked 3 AGC Alarm - signal out of range 5 RS Frame sync alarm 7 … |
| 1.3.6.1.4.1.6247.24.1.3.2 | Nodecdm570RxParams | |||
| 1.3.6.1.4.1.6247.24.1.3.2.1 | Scalarcdm570RxBERMultiplier | read-only | current | Estimated corrected BER. The BER is calculated by mubliplying the Multiplier by 10E-10. Calculuation: RxBER = (Multiplier) * 0.0000000001 Returns 2147483647 (m… |
| 1.3.6.1.4.1.6247.24.1.3.2.2 | Scalarcdm570BufferFillState | read-only | current | Unit returns the value of the buffer fill state, between 1 to 99%. Returns 0 if demodulator is unlocked. Returns -1 if buffer is disabled. |
| 1.3.6.1.4.1.6247.24.1.3.2.3 | Scalarcdm570RxFrequencyOffset | read-only | current | Unit returns the value of the measured frequency offset of the carrier being demodulated in Hz. Units = Hz. Resolution 100 Hz. Range = -200,000 Hz to 0 Hz and … |
| 1.3.6.1.4.1.6247.24.1.3.2.4 | Scalarcdm570RxSignalLevel | read-only | current | Unit returns the value of the Rx signal level, in dBm, between -99 dBm and -5 dBm. Returns -100 if signal is less than -99 dBm. Returns -4 if signal is greater… |
| 1.3.6.1.4.1.6247.24.1.3.2.5 | Scalarcdm570RxEbNo | read-only | current | Unit returns the value of Eb/No, between 0 and 16 db. Units = 0.1 dB. Resolution 0.1 dB. Returns 999 if demod is unlocked. For values greater than 16 dB, the r… |
| 1.3.6.1.4.1.6247.24.1.3.3 | Nodecdm570EventLog | |||
| 1.3.6.1.4.1.6247.24.1.3.3.1 | Tablecdm570StoredEventsTable | not-accessible | current | The table for stored events. |
| 1.3.6.1.4.1.6247.24.1.3.3.1.1 | Rowcdm570StoredEventsEntry | not-accessible | current | The entry for the stored events table. |
| 1.3.6.1.4.1.6247.24.1.3.3.1.1.1 | Columncdm570EventIndex | read-only | current | The index for stored events table. |
| 1.3.6.1.4.1.6247.24.1.3.3.1.1.2 | Columncdm570EventDate | read-only | current | The date of the event in the form ddmmyy, where dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99) |
| 1.3.6.1.4.1.6247.24.1.3.3.1.1.3 | Columncdm570EventTime | read-only | current | The time of the event in the form hhmmss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59) |
| 1.3.6.1.4.1.6247.24.1.3.3.1.1.4 | Columncdm570EventDescription | read-only | current | The event description string with following format: {1 of the following: Clear, Fault, Info} - {Texual Description of Event} |
| 1.3.6.1.4.1.6247.24.1.3.3.2 | Scalarcdm570ClearAllStoredEvents | read-write | current | Forces the software to clear the event log. This is a command only. |
| 1.3.6.1.4.1.6247.24.1.3.4 | Nodecdm570Statistics | |||
| 1.3.6.1.4.1.6247.24.1.3.4.1 | Scalarcdm570StatisticsSampleInterval | read-write | current | Used to set the sample interval for the statistics logging function, where the enumerated lists goes from 0 to 9 in 10 minute steps. Setting 0 disables the sta… |
| 1.3.6.1.4.1.6247.24.1.3.4.2 | Tablecdm570StoredStatisticsTable | not-accessible | current | Description. |
| 1.3.6.1.4.1.6247.24.1.3.4.2.1 | Rowcdm570StoredStatisticsEntry | not-accessible | current | Entry for stored statistics table. |
| 1.3.6.1.4.1.6247.24.1.3.4.2.1.1 | Columncdm570StatisticIndex | read-only | current | Index for stored statistics table. |
| 1.3.6.1.4.1.6247.24.1.3.4.2.1.2 | Columncdm570StatisticDate | read-only | current | The date of the statistic in the form ddmmyy, where: dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99) |
| 1.3.6.1.4.1.6247.24.1.3.4.2.1.3 | Columncdm570StatisticTime | read-only | current | The time of the statistic in the form hhmmss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59) |
| 1.3.6.1.4.1.6247.24.1.3.4.2.1.4 | Columncdm570StatisticMinEbNo | read-only | current | Minimum Eb/No during sample period. Units = 0.1 dB. Returns 999 if demod was unlocked during sample period. |
| 1.3.6.1.4.1.6247.24.1.3.4.2.1.5 | Columncdm570StatisticAvgEbNo | read-only | current | Minimum Eb/No during sample period. Units = 0.1 dB. Returns 999 if demod was unlocked during sample period. |
| 1.3.6.1.4.1.6247.24.1.3.4.2.1.6 | Columncdm570StatisticMaxTxPowerIncrease | read-only | current | Max. Tx power level increase during sample period. Units = 0.1 dB |
| 1.3.6.1.4.1.6247.24.1.3.4.2.1.7 | Columncdm570StatisticAvgTxPowerIncrease | read-only | current | Average Tx power level increase during sample period. Units = 0.1 dB |
| 1.3.6.1.4.1.6247.24.1.3.4.3 | Scalarcdm570ClearAllStoredStatistics | read-write | current | Forces the software to clear the statistics log. This is a command only. |
| 1.3.6.1.4.1.6247.24.1.3.5 | Nodecdm570AUPCParams | |||
| 1.3.6.1.4.1.6247.24.1.3.5.1 | Scalarcdm570AUPCRemoteDemodEbNo | read-only | current | Returns the value of the Eb/No ofthe remote demodulator. Units = 0.1 dB Responds 999 = remote demod unlocked. Responds 0 = EDMAC is disabled. |
| 1.3.6.1.4.1.6247.24.1.3.5.2 | Scalarcdm570AUPCTxPowerIncrease | read-only | current | Returns the increase in Tx power level, in 0.1 dB (from the nominal setting) due to the action of AUPC. Responds with 999 if AUPC is disabled. |
| 1.3.6.1.4.1.6247.24.1.3.6 | Nodecdm570ODUParams | |||
| 1.3.6.1.4.1.6247.24.1.4 | Nodecdm570Test | |||
| 1.3.6.1.4.1.6247.24.1.4.1 | Scalarcdm570UnitTestMode | read-write | current | Unit Test Mode where: 0 = Normal Mode 1 = IF Loopback 2 = Digital Loopback 3 = IO Loopback 4 = RF Loopback 5 = Tx CW 6 = Tx Alternating Pattern |
| 1.3.6.1.4.1.6247.24.1.5 | Nodecdm570SaveLoad | |||
| 1.3.6.1.4.1.6247.24.1.5.1 | Scalarcdm570ConfigurationSave | read-write | current | Causes the device to store the current modem configuration in configuration memory location defined by the argument (0 to 9). This is a COMMAND ONLY. Get alway… |
| 1.3.6.1.4.1.6247.24.1.5.2 | Scalarcdm570ConfigurationLoad | read-write | current | Causes the device to retrieve a previously stored modem configuration from configuration memory location defined by the argument (0 to 9). This is a COMMAND ON… |
| 1.3.6.1.4.1.6247.24.1.6 | Nodecdm570Util | |||
| 1.3.6.1.4.1.6247.24.1.6.1 | Nodecdm570Buffer | |||
| 1.3.6.1.4.1.6247.24.1.6.1.1 | Scalarcdm570ReCenterBuffer | read-write | current | Forces the software to recenter the receive Plesiochronous/Doppler buffer. This is a command only. |
| 1.3.6.1.4.1.6247.24.1.6.2 | Nodecdm570RealTimeClock | |||
| 1.3.6.1.4.1.6247.24.1.6.2.1 | Scalarcdm570RTCDate | read-write | current | A date in the form dd/mm/yy, where dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99) |
| 1.3.6.1.4.1.6247.24.1.6.2.2 | Scalarcdm570RTCTime | read-write | current | A time in the form hh:mm:ss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59) |
| 1.3.6.1.4.1.6247.24.1.6.3 | Nodecdm570InternalReference | |||
| 1.3.6.1.4.1.6247.24.1.6.3.2 | Scalarcdm570WarmUpDelay | read-write | current | Warm-up delay for internal frequency reference (OCXO), where: 0 = Disabled (instant on - no delay for OCXO to reach temperature) 1 = Enabled (unit waits until … |
| 1.3.6.1.4.1.6247.24.1.6.3.3 | Scalarcdm570WarmUpCountdown | read-write | current | As a query, returns the Warm-up delay countdown in seconds remaining. As a command, only takes the argument 0 and is used to truncate the warm-up delay period … |
| 1.3.6.1.4.1.6247.24.1.6.4 | Nodecdm570ID | |||
| 1.3.6.1.4.1.6247.24.1.6.4.1 | Scalarcdm570CircuitID | read-write | current | Sets or queries the user-defined Circuit ID string, which is a fixed length of 24 characters. Valid characters include: Space ( ) * + - , . / 0 thru 9 and A th… |
| 1.3.6.1.4.1.6247.24.1.6.5 | Nodecdm570Redundancy | |||
| 1.3.6.1.4.1.6247.24.1.6.5.1 | Scalarcdm570RedundancyState | read-only | current | Unit returns the redundancy state of the unit, where: 0 = Offline 1 = Online |
| 1.3.6.1.4.1.6247.24.1.6.5.2 | Scalarcdm570ForceRedundentSwitch | read-write | current | Force redundundent switch command. |
| 1.3.6.1.4.1.6247.24.1.6.6 | Nodecdm570ODUComms | |||
| 1.3.6.1.4.1.6247.24.1.6.6.1 | Scalarcdm570ODUCommsEnabled | read-write | current | ODU Comms, where 0 = Disabled 1 = Enabled |
| 1.3.6.1.4.1.6247.24.2 | Nodecdm570Notifications | |||
| 1.3.6.1.4.1.6247.24.2.0 | Nodecdm570NotificationsPrefix | |||
| 1.3.6.1.4.1.6247.24.2.0.1 | Notificationcdm570UnitAlarm | current | Modem Unit Faults Trap | |
| 1.3.6.1.4.1.6247.24.2.0.2 | Notificationcdm570TxTrafficAlarm | current | Modem TX Traffic Faults Trap | |
| 1.3.6.1.4.1.6247.24.2.0.3 | Notificationcdm570RxTrafficAlarm | current | Modem RX Traffic Faults Trap | |
| 1.3.6.1.4.1.6247.24.3 | Nodecdm570Conformance | |||
| 1.3.6.1.4.1.6247.24.3.1 | Nodecdm570Groups | |||
| 1.3.6.1.4.1.6247.24.3.1.1 | Groupcdm570ObjectsGroup | current | CDM-570 (Both L-Band and IF-Band) Objects Group. | |
| 1.3.6.1.4.1.6247.24.3.1.2 | Groupcdm570NotificationsGroup | current | CDM-570 (Both L-Band and IF-Band) Notifications Group. | |
| 1.3.6.1.4.1.6247.24.3.2 | Nodecdm570Compliances | |||
| 1.3.6.1.4.1.6247.24.3.2.1 | Compliancecdm570Compliance | current | CDM-570 (Both L-Band and IF-Band) Compliance. |