CDX-6500-COMMON-MIB
351 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter enterprises Gauge IpAddress mgmt NetworkAddress TimeTicks |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.449 | Nodecodex | |||
| 1.3.6.1.4.1.449.2 | NodecdxProductSpecific | |||
| 1.3.6.1.4.1.449.2.1 | Nodecdx6500 | |||
| 1.3.6.1.4.1.449.2.1.1 | Nodecdx6500NodeMgmt | |||
| 1.3.6.1.4.1.449.2.1.1.1 | Nodecdx6500NMSNMPGroup | |||
| 1.3.6.1.4.1.449.2.1.1.1.1 | Scalarcdx6500SNMPPrimUDPChan | read-write | mandatory | The primary UDP port used by the SNMP Agent has a default value of 161. |
| 1.3.6.1.4.1.449.2.1.1.1.2 | Scalarcdx6500SNMPSecUDPChan | read-write | mandatory | The secondary UDP port used by the SNMP Agent has a default value of 162. |
| 1.3.6.1.4.1.449.2.1.1.1.3 | Scalarcdx6500SNMPAgentTimer | read-write | mandatory | An internal timer used by the SNMP agent, unit is a 20 ms tick. |
| 1.3.6.1.4.1.449.2.1.1.1.4 | Scalarcdx6500SNMPTrapEnable | read-write | mandatory | A control object to disable or enable the SNMP agent's trap send capability. newvalDisable : same functionality as 'disable', new enumeration added for RFC1155… |
| 1.3.6.1.4.1.449.2.1.1.1.5 | Scalarcdx6500SNMPBootAgent | write-only | mandatory | A control object. Setting to value `boot' will cause the SNMP agent to boot. |
| 1.3.6.1.4.1.449.2.1.1.1.6 | Scalarcdx6500SNMPResetStats | write-only | mandatory | A control object, which when set to value `reset', will cause the SNMP agent to reset all its statistics. |
| 1.3.6.1.4.1.449.2.1.1.1.7 | Scalarcdx6500SNMPLastTrap | read-only | mandatory | The interesting information portion of the last trap PDU issued by the SNMP Agent. |
| 1.3.6.1.4.1.449.2.1.1.1.8 | Scalarcdx6500SNMPGenTrapsType | read-write | mandatory | Choice between generic traps as defined in RFC or correponding enterprise specific traps to be generated by the node. This attribute is applicable only when ge… |
| 1.3.6.1.4.1.449.2.1.1.1.9 | Tablecdx6500SNMPTrapThrottleTable | not-accessible | mandatory | Throttling table. |
| 1.3.6.1.4.1.449.2.1.1.1.9.1 | Rowcdx6500SNMPTrapThrottleEntry | not-accessible | mandatory | Entry representing throttling parameters. |
| 1.3.6.1.4.1.449.2.1.1.1.9.1.1 | Columncdx6500SNMPTrapNumber | read-only | mandatory | Trap number to be throttled. |
| 1.3.6.1.4.1.449.2.1.1.1.9.1.2 | Columncdx6500SNMPMaxNumOfTraps | read-write | mandatory | Number of traps allowed to be generated in the throttling period. |
| 1.3.6.1.4.1.449.2.1.1.1.9.1.3 | Columncdx6500SNMPThrottlingPeriod | read-write | mandatory | Throttling time period in seconds. Value 0 means trap is not throttled. |
| 1.3.6.1.4.1.449.2.1.1.1.9.1.4 | Columncdx6500SNMPNewTrapLevel | read-write | mandatory | New severity level for the trap. |
| 1.3.6.1.4.1.449.2.1.1.1.9.1.5 | Columncdx6500SNMPEntryStatus | read-write | mandatory | Table row status. Setting the value to deleted removes the entry from the table. |
| 1.3.6.1.4.1.449.2.1.1.1.10 | Scalarcdx6500SNMPSetControl | read-only | mandatory | Snmp Set operation control off : snmp set operation is not allowed on : snmp set operation is allowed. |
| 1.3.6.1.4.1.449.2.1.1.1.11 | Scalarcdx6500SNMPIpAddress | read-write | mandatory | IP address for this node. |
| 1.3.6.1.4.1.449.2.1.1.2 | Nodecdx6500NMNodeParametersGroup | |||
| 1.3.6.1.4.1.449.2.1.1.2.1 | Nodecdx6500NMNPconfig | |||
| 1.3.6.1.4.1.449.2.1.1.2.1.1 | Scalarcdx6500NMNPCnodeName | read-only | mandatory | This parameter identifies the node with a name, which appears at the top of control terminal menus and reports. Range is 0 to 8 alphanumeric characters. |
| 1.3.6.1.4.1.449.2.1.1.2.1.2 | Scalarcdx6500NMNPCnodeNum | read-only | mandatory | The node number identifies the node for X.25 routing purposes to prevent routing loops. |
| 1.3.6.1.4.1.449.2.1.1.2.1.3 | Scalarcdx6500NMNPCnodeAddress | read-only | mandatory | The node address specifies the main part of the network address for calls destined within this node: PAD port or node resource (for example, control port) call… |
| 1.3.6.1.4.1.449.2.1.1.2.1.4 | Scalarcdx6500NMNPCchassis | read-only | mandatory | This parameters identifies the type of chassis that this node is residing in. This is necessary in order to correctly interpret the fan and power supply status… |
| 1.3.6.1.4.1.449.2.1.1.2.1.5 | Scalarcdx6500NMNPCdate | read-only | mandatory | The node date used for date stamps of events and traps. The format of the string is yyyymmmdd, year: four digits, month: first three letters of the month, day:… |
| 1.3.6.1.4.1.449.2.1.1.2.1.6 | Scalarcdx6500NMNPCtime | read-only | mandatory | The node time used for time stamps of events and traps. The format of the string is hhmmss, hour: 00..23, minute 00..59, second: 00..59. |
| 1.3.6.1.4.1.449.2.1.1.2.1.7 | Scalarcdx6500NMNPCportUtil | read-only | mandatory | Port Utilization Threshold (%). This parameter sets the alarm level for traffic on every port in a node. The traffic is checked over a 64-second interval to gi… |
| 1.3.6.1.4.1.449.2.1.1.2.1.8 | Scalarcdx6500NMNPCbuffUtil | read-only | mandatory | Buffer Utilization Threshold (%). This parameter sets the alarm level for data buffers. When data passes through a node, buffers provide temporary storage. If … |
| 1.3.6.1.4.1.449.2.1.1.2.1.9 | Scalarcdx6500NMNPCcpuUtil | read-only | mandatory | CPU Utilization Threshold (%). If the CPU is not processing data, it is running diagnostic checks. It is never idle. This parameter specifies the amount of tim… |
| 1.3.6.1.4.1.449.2.1.1.2.1.10 | Scalarcdx6500NMNPCportErr | read-only | mandatory | Port Error Threshold. This threshold specifies the number of port errors (such as parity or framing errors) that can be detected before a medium severity alarm… |
| 1.3.6.1.4.1.449.2.1.1.2.1.11 | Scalarcdx6500NMNPCalarmTmr | read-only | mandatory | Alarm Threshold Timer. This parameter prevents a node from sending threshold alarms too frequently. If a node generates an alarm the threshold alarm timer is s… |
| 1.3.6.1.4.1.449.2.1.1.2.1.12 | Scalarcdx6500NMNPCmaxRoutHops | read-only | mandatory | Maximum Routing Hops.This parameter specifies the maximum number of nodes a call may pass through before reaching its destination. |
| 1.3.6.1.4.1.449.2.1.1.2.1.13 | Scalarcdx6500NMNPCctpSubAddr | read-only | mandatory | This parameter specifies the Control Port (CTP) Subaddress. Calls with network address composed of the node address and this subaddress will be routed to the c… |
| 1.3.6.1.4.1.449.2.1.1.2.1.14 | Scalarcdx6500NMNPCctpIdleTime | read-only | mandatory | Control Port Idle Disconnect Time (minutes). This specifies how many minutes of inactivity can occur before the control terminal is automatically disconnected |
| 1.3.6.1.4.1.449.2.1.1.2.1.15 | Scalarcdx6500NMNPCalmDist | read-only | deprecated | This object has been replaced by cdx6500NMNPCalmDistrib. |
| 1.3.6.1.4.1.449.2.1.1.2.1.16 | Scalarcdx6500NMNPCalmMmem | read-only | mandatory | Alarm Printer Mnemonic. This specifies the mnemonic name for the destination of alarms sent by the node (if Alarm Distribution = PRIN). This destination is usu… |
| 1.3.6.1.4.1.449.2.1.1.2.1.17 | Scalarcdx6500NMNPCalmSelect | read-only | deprecated | This object has been replaced by cdx6500NMNPCalmSelection. |
| 1.3.6.1.4.1.449.2.1.1.2.1.18 | Scalarcdx6500NMNPCbroadPortSubad | read-only | mandatory | This specifies the broadcast port subaddress for this node. Calls with network address composed of the node address and this subaddress will be routed to the b… |
| 1.3.6.1.4.1.449.2.1.1.2.1.19 | Scalarcdx6500NMNPCnoBroadNets | read-only | mandatory | Number of Broadcast Nets. This specifies the number of Broadcast Networks to which this node can send broadcast messages. A value of 0 will disable broadcast f… |
| 1.3.6.1.4.1.449.2.1.1.2.1.20 | Scalarcdx6500NMNPCnoBroadInCh | read-only | mandatory | Number of Broadcast Input Channels. This specifies the number of simultaneous broadcast messages that can be received. |
| 1.3.6.1.4.1.449.2.1.1.2.1.21 | Scalarcdx6500NMNPCbillMnem | read-only | mandatory | When billing records need to be printed, the node will use this mnemonic to call and send the records to this destination. This location is usually a printer u… |
| 1.3.6.1.4.1.449.2.1.1.2.1.22 | Scalarcdx6500NMNPCbillThresh | read-only | mandatory | When the number of billing records queued up equals this threshold, a call will be placed to the logging device to dump the billing records. |
| 1.3.6.1.4.1.449.2.1.1.2.1.23 | Scalarcdx6500NMNPCmaxBill | read-only | mandatory | This is the maximum number of billing records the node will be allowed to store to be printed. Billing records created after this maximum is reached will be lo… |
| 1.3.6.1.4.1.449.2.1.1.2.1.24 | Scalarcdx6500NMNPCbillTimer | read-only | mandatory | If billing records have been stored for printing for this amount of time (in minutes) without reaching the threshold, a call will be made so that they can be p… |
| 1.3.6.1.4.1.449.2.1.1.2.1.25 | Scalarcdx6500NMNPCpvcBill | read-only | mandatory | At this interval the billing records will be gathered and printed for all of the PVC's in the node that have billing turned on. |
| 1.3.6.1.4.1.449.2.1.1.2.1.26 | Scalarcdx6500NMNPCmaxCalls | read-only | mandatory | Limiting the number of calls allowed in the node will eliminate data loss in extreme traffic conditions. |
| 1.3.6.1.4.1.449.2.1.1.2.1.27 | Scalarcdx6500NMNPCpadBulletin | read-only | mandatory | PAD Bulletin Message. Specifies the message that appears when a terminal connects to PAD port and enters Command Mode. To have no message appear, select blank. |
| 1.3.6.1.4.1.449.2.1.1.2.1.28 | Scalarcdx6500NMNPCpadBanner | read-only | mandatory | PAD Banner Message. Specifies the message PAD ports send to attached terminals when they enter Command Mode. These special characters can be used to display ce… |
| 1.3.6.1.4.1.449.2.1.1.2.1.29 | Scalarcdx6500NMNPCdcpFac | read-only | mandatory | This defines the facility used to carry DCP information at call setup and reconnection time in Call Request and Call Accept packets through the 6500 network. C… |
| 1.3.6.1.4.1.449.2.1.1.2.1.30 | Scalarcdx6500NMNPCtrafficPri | read-only | mandatory | Traffic Priority. This is the default traffic priority to be used on the node. newvalLow : same functionality as 'low', new enumeration added for RFC1155 compa… |
| 1.3.6.1.4.1.449.2.1.1.2.1.31 | Scalarcdx6500NMNPCtrafficStep | read-only | mandatory | Traffic Priority Step. This specifies the number of packets to be transmitted for each lower priority packet transmitted. |
| 1.3.6.1.4.1.449.2.1.1.2.1.32 | Scalarcdx6500NMNPCpropProtId | read-only | mandatory | This is the Codex Proprietary Protocol ID. Its value is put in the first byte of the Protocol Identifier field of the CUD in the Call Request packets for proto… |
| 1.3.6.1.4.1.449.2.1.1.2.1.33 | Scalarcdx6500NMNPClanSubAddr | read-only | mandatory | Calls with network address composed of the node address and this subaddress will be routed to a LAN Connection in this node. |
| 1.3.6.1.4.1.449.2.1.1.2.1.34 | Scalarcdx6500NMNPCMaxFrameSize | read-only | mandatory | The largest datalink level frame that will ever be received on any link. On WAN links this does not include space that is reserved internally for trailers. |
| 1.3.6.1.4.1.449.2.1.1.2.1.35 | Scalarcdx6500NMNPCCodexGroupFacility | read-only | mandatory | This is the facility used in call packets on Codex 6500 links for passing CODEX PRIVATE facilities other than Hop Count and DCP facilities between 4.xx nodes. … |
| 1.3.6.1.4.1.449.2.1.1.2.1.36 | Scalarcdx6500NMNPCalmDistrib | read-only | mandatory | Distribution of alarms is controlled by specifying: NONE - no alarm is sent\r\n\ CTP - send alarms to Control Port Terminal\r\n\ PRIN - send alarms to Printer … |
| 1.3.6.1.4.1.449.2.1.1.2.1.37 | Scalarcdx6500NMNPCalmSelection | read-only | mandatory | Alarm type reporting by the node: NONE - no alarms reported. HIGH - high severity alarms reported. MED - medium severity alarms reported. LOW - low severity al… |
| 1.3.6.1.4.1.449.2.1.1.2.1.38 | Scalarcdx6500NMNPChopFacility | read-only | mandatory | Hop Count Facility. This is the facility used in call packets on X.25 links with the INL option for network routing. This should be the SAME in all nodes in th… |
| 1.3.6.1.4.1.449.2.1.1.2.1.39 | Scalarcdx6500NMNPCnumNccpDevices | read-only | mandatory | This is the number of NCCP devices. |
| 1.3.6.1.4.1.449.2.1.1.2.1.40 | Scalarcdx6500NMNPCmaxCallid | read-only | mandatory | This is the maximum number of Call id numbers that go in the Calling Identifier table. This table can have a maximum of 512 entries. Each entry of 30 digits. |
| 1.3.6.1.4.1.449.2.1.1.2.2 | Nodecdx6500NMNPinvent | |||
| 1.3.6.1.4.1.449.2.1.1.2.2.1 | Scalarcdx6500NMNPIproductType | read-only | mandatory | Identifies a general class of feature set for the product, e.g. 6504PLUS Asynchronous PAD or 6520 Branch Node |
| 1.3.6.1.4.1.449.2.1.1.2.2.2 | Scalarcdx6500NMNPIsoftwareSrc | read-only | mandatory | The source of software currently running on the node. prom - CPU running from code in PROM. download - CPU downloading code into RAM. promLoadingRAM - CPU runn… |
| 1.3.6.1.4.1.449.2.1.1.2.2.3 | Scalarcdx6500NMNPIserialNum | read-only | mandatory | The serial number of the motherboard. |
| 1.3.6.1.4.1.449.2.1.1.2.2.4 | Scalarcdx6500NMNPIpromRevision | read-only | mandatory | The PROM software revision. |
| 1.3.6.1.4.1.449.2.1.1.2.2.5 | Scalarcdx6500NMNPIdlCodeRevision | read-only | optional | The downloaded software revision. Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.2.6 | Scalarcdx6500NMNPIdlCodeSource | read-only | optional | The source of downloaded software. Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.2.7 | Scalarcdx6500NMNPIdlCodeSize | read-only | optional | The size of downloaded software in bytes. Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.2.8 | Scalarcdx6500NMNPIflashStatus | read-only | optional | The status of use of flash memory. Applicable only to 6500 platforms. newvalEnabled : same functionality as 'enabled', new enumeration added for RFC1155 compat… |
| 1.3.6.1.4.1.449.2.1.1.2.2.9 | Scalarcdx6500NMNPIflashIdCur | read-only | mandatory | Name and version of software stored in flash. This refers to the currently selected bank of flash when there is an alternate bank of flash installed. |
| 1.3.6.1.4.1.449.2.1.1.2.2.10 | Scalarcdx6500NMNPIflashIdAlt | read-only | optional | Name and version of software contained by the alternate bank of flash (if installed). Applicable to 6520 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.2.11 | Scalarcdx6500NMNPIflashSizeCur | read-only | mandatory | Size of software stored in flash. This refers to the currently selected bank of flash when there is an alternate bank of flash installed. |
| 1.3.6.1.4.1.449.2.1.1.2.2.12 | Scalarcdx6500NMNPIflashSizeAlt | read-only | optional | Size of software in the alternate bank of flash (bytes). Applicable to 6520 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.2.13 | Tablecdx6500NMNPIinventTable | not-accessible | mandatory | A list of the node's boards. |
| 1.3.6.1.4.1.449.2.1.1.2.2.13.1 | Rowcdx6500NMNPIinventEntry | not-accessible | mandatory | Each entry contains a board number, board type, number of ports, status, and serial number. |
| 1.3.6.1.4.1.449.2.1.1.2.2.13.1.1 | Columncdx6500NMNPIinventBoard | read-only | mandatory | The board number. This is used to index the boards in a node. |
| 1.3.6.1.4.1.449.2.1.1.2.2.13.1.2 | Columncdx6500NMNPIinventType | read-only | mandatory | The board type. A description of the type of board. |
| 1.3.6.1.4.1.449.2.1.1.2.2.13.1.3 | Columncdx6500NMNPIinventPorts | read-only | mandatory | The number of I/O ports for this board. |
| 1.3.6.1.4.1.449.2.1.1.2.2.13.1.4 | Columncdx6500NMNPIinventStatus | read-only | mandatory | The status of the board |
| 1.3.6.1.4.1.449.2.1.1.2.2.13.1.5 | Columncdx6500NMNPIinventSerial | read-only | mandatory | The serial number of the board |
| 1.3.6.1.4.1.449.2.1.1.2.2.13.1.6 | Columncdx6500NMNPIinventAssy | read-only | mandatory | The assembly number of the board |
| 1.3.6.1.4.1.449.2.1.1.2.2.13.1.7 | Columncdx6500NMNPIinventRev | read-only | mandatory | The revision level of the board |
| 1.3.6.1.4.1.449.2.1.1.2.2.13.1.8 | Columncdx6500NMNPIinventDIM1 | read-only | mandatory | The type of interface specified by DIM 1. |
| 1.3.6.1.4.1.449.2.1.1.2.2.13.1.9 | Columncdx6500NMNPIinventDIM2 | read-only | mandatory | The type of interface specified by DIM 2. |
| 1.3.6.1.4.1.449.2.1.1.2.2.14 | Tablecdx6500NMNPIinventPortConfigTable | not-accessible | mandatory | A list of the node's Port Configuration. |
| 1.3.6.1.4.1.449.2.1.1.2.2.14.1 | Rowcdx6500NMNPIinventPortConfigEntry | not-accessible | mandatory | Each entry contains a port configuration. |
| 1.3.6.1.4.1.449.2.1.1.2.2.14.1.1 | Columncdx6500NMNPIinventPortNum | read-only | mandatory | The port number. This is used to index the ports in a node. |
| 1.3.6.1.4.1.449.2.1.1.2.2.14.1.2 | Columncdx6500NMNPIinventPortConfig | read-only | mandatory | The port configuration on each board. |
| 1.3.6.1.4.1.449.2.1.1.2.3 | Nodecdx6500NMNPstats | |||
| 1.3.6.1.4.1.449.2.1.1.2.3.1 | Scalarcdx6500NMNPSevLastOccPower | read-only | mandatory | The last time the node was turned on. |
| 1.3.6.1.4.1.449.2.1.1.2.3.2 | Scalarcdx6500NMNPSevLastOccReset | read-only | mandatory | The last time the reset button was pressed. |
| 1.3.6.1.4.1.449.2.1.1.2.3.3 | Scalarcdx6500NMNPSevLastOccReboot | read-only | mandatory | The last time the node was rebooted. |
| 1.3.6.1.4.1.449.2.1.1.2.3.4 | Scalarcdx6500NMNPSevLastOccWDTimer | read-only | mandatory | The last time the watch dog timer expired. |
| 1.3.6.1.4.1.449.2.1.1.2.3.5 | Scalarcdx6500NMNPSevLastOccConfig | read-only | mandatory | The last time the configuration memory was changed or downloaded. |
| 1.3.6.1.4.1.449.2.1.1.2.3.6 | Scalarcdx6500NMNPSstatusFan | read-only | mandatory | The operational status of the cooling fan. newvalNotMonitored : same functionality as 'notMonitored', new enumeration added for RFC1155 compatibility. |
| 1.3.6.1.4.1.449.2.1.1.2.3.7 | Scalarcdx6500NMNPSstatusPwrSy | read-only | deprecated | The operational status of the power supply. This object is being replaced by cdx6500NMNPSstatusPowerSy. newvalNotMonitored : same functionality as 'notMonitore… |
| 1.3.6.1.4.1.449.2.1.1.2.3.8 | Scalarcdx6500NMNPScmemSizeComp | read-only | mandatory | Size of compressed configuration memory available (free) in bytes. |
| 1.3.6.1.4.1.449.2.1.1.2.3.9 | Scalarcdx6500NMNPScmemUseComp | read-only | mandatory | Size of compressed configuration memory in use in bytes. |
| 1.3.6.1.4.1.449.2.1.1.2.3.10 | Scalarcdx6500NMNPScmemSizeUncomp | read-only | mandatory | Size of uncompressed configuration memory available (free) in bytes. |
| 1.3.6.1.4.1.449.2.1.1.2.3.11 | Scalarcdx6500NMNPScmemUseUnComp | read-only | mandatory | Size of uncompressed configuration memory in use in bytes. |
| 1.3.6.1.4.1.449.2.1.1.2.3.12 | Scalarcdx6500NMNPScallsInPlaceCur | read-only | mandatory | Number of X.25 calls. The number of calls currently in place. |
| 1.3.6.1.4.1.449.2.1.1.2.3.13 | Scalarcdx6500NMNPScallsInPlaceMax | read-only | mandatory | Number of X.25 calls gauge. The maximum number of calls since the last reset. |
| 1.3.6.1.4.1.449.2.1.1.2.3.14 | Scalarcdx6500NMNPScallsPerSecCur | read-only | mandatory | Rate of X.25 calls. The number of calls/sec. currently in place. |
| 1.3.6.1.4.1.449.2.1.1.2.3.15 | Scalarcdx6500NMNPScallsPerSecMax | read-only | mandatory | Rate of X.25 calls gauge. The maximum number of calls/sec. since the last reset. |
| 1.3.6.1.4.1.449.2.1.1.2.3.16 | Scalarcdx6500NMNPSpvcConnectCur | read-only | mandatory | Permanent virtual circuit connections. The number currently in place. |
| 1.3.6.1.4.1.449.2.1.1.2.3.17 | Scalarcdx6500NMNPSPVCConnectMax | read-only | mandatory | Permanent virtual circuit connections. The maximum since the last reset. |
| 1.3.6.1.4.1.449.2.1.1.2.3.18 | Scalarcdx6500NMNPSbuffDataAvail | read-only | optional | The number of data buffers available. Applicable to all platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.19 | Scalarcdx6500NMNPSbuffDataUse | read-only | optional | The number of data buffers in use. Applicable to all platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.20 | Scalarcdx6500NMNPSbuffDataGauge | read-only | optional | The maximum number of data buffers in use since last reset Applicable to all platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.21 | Scalarcdx6500NMNPSbuffPacketAvail | read-only | optional | The number of packet buffers available. Applicable to all platforms except VG100 . |
| 1.3.6.1.4.1.449.2.1.1.2.3.22 | Scalarcdx6500NMNPSbuffPacketUse | read-only | optional | The number of packet buffers in use. Applicable to all platforms except VG100. |
| 1.3.6.1.4.1.449.2.1.1.2.3.23 | Scalarcdx6500NMNPSbuffPacketExhaust | read-only | optional | The number of times the packet buffer pool has been exhausted since last reset. Applicable to all platforms except VG100. |
| 1.3.6.1.4.1.449.2.1.1.2.3.24 | Scalarcdx6500NMNPSbuffMgtAvail | read-only | optional | The number of management buffers available. Applicable to all platforms except VG100. |
| 1.3.6.1.4.1.449.2.1.1.2.3.25 | Scalarcdx6500NMNPSbuffMgtUse | read-only | optional | The number of management buffers in use. Applicable to all platforms except VG100. |
| 1.3.6.1.4.1.449.2.1.1.2.3.26 | Scalarcdx6500NMNPSbuffMgtExhaust | read-only | optional | The number of times the management buffer pool has been exhausted since last reset. Applicable to all platforms except VG100. |
| 1.3.6.1.4.1.449.2.1.1.2.3.27 | Scalarcdx6500NMNPSrateCurChar | read-only | mandatory | Node throughput, number of current chararacters/second for the node. |
| 1.3.6.1.4.1.449.2.1.1.2.3.28 | Scalarcdx6500NMNPSrateCurPkt | read-only | mandatory | Node throughput, number of current packets/second for the node. |
| 1.3.6.1.4.1.449.2.1.1.2.3.29 | Scalarcdx6500NMNPSrateMaxChar | read-only | mandatory | Node throughput gauge, Number of maximum characters/second for the node since last reset |
| 1.3.6.1.4.1.449.2.1.1.2.3.30 | Scalarcdx6500NMNPSrateMaxPkt | read-only | mandatory | Node throughput gauge, Number of maximum packets/second for the node since last reset |
| 1.3.6.1.4.1.449.2.1.1.2.3.31 | Scalarcdx6500NMNPSmemEprom | read-only | optional | Amount of memory available on the processor card in bytes. Applicable to 6520 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.32 | Scalarcdx6500NMNPSmemDram | read-only | optional | Amount of memory used for data buffers in bytes. Applicable to 6520 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.33 | Scalarcdx6500NMNPSmemFlashCur | read-only | optional | The size of the flash module in bytes. This refers to the currently selected bank of flash when there is an alternate bank of flash installed. Applicable to 65… |
| 1.3.6.1.4.1.449.2.1.1.2.3.34 | Scalarcdx6500NMNPSmemFlashAlt | read-only | optional | The size of the alternate flash module in bytes. Applicable to 6520 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.35 | Scalarcdx6500NMNPScpuUtil | read-only | optional | Percentage of time the CPU processed traffic data (as opposed performing diagnositic tests or processing node control data) to in the last 64 seconds. Applicab… |
| 1.3.6.1.4.1.449.2.1.1.2.3.36 | Scalarcdx6500NMNPSDisplayNumImage | read-only | optional | Front panel numeric display. Applicable to 6520 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.37 | Scalarcdx6500NMNPSDisplayLEDstatus | read-only | optional | Front panel status LED. Applicable to 6520 platforms. newvalOff : same functionality as 'off', new enumeration added for RFC1155 compatibility. |
| 1.3.6.1.4.1.449.2.1.1.2.3.38 | Scalarcdx6500NMNPSDisplayLEDdiag | read-only | optional | Front panel fault (or service) LED. Applicable to 6520 platforms. newvalOff : same functionality as 'off', new enumeration added for RFC1155 compatibility. |
| 1.3.6.1.4.1.449.2.1.1.2.3.39 | Scalarcdx6500NMNPSdefaultNode | not-accessible | mandatory | A control object. Setting to value default will cause the current configuration of the entire node to change back to the default settings. CAUTION: If you impl… |
| 1.3.6.1.4.1.449.2.1.1.2.3.40 | Tablecdx6500NMNPSresetStatTable | not-accessible | mandatory | A list of Port Statistic Reset entries. |
| 1.3.6.1.4.1.449.2.1.1.2.3.40.1 | Rowcdx6500NMNPSresetStatEntry | not-accessible | mandatory | Each entry contains a port number and a control to reset statistics for that port. |
| 1.3.6.1.4.1.449.2.1.1.2.3.40.1.1 | Columncdx6500NMNPSresetStatPort | not-accessible | mandatory | The port number value for this object directs the statistics reset command to that port. |
| 1.3.6.1.4.1.449.2.1.1.2.3.40.1.2 | Columncdx6500NMNPSresetStatStatus | write-only | mandatory | A value of reset will cause a port's statistics to be reset. A value of noReset has no effect. |
| 1.3.6.1.4.1.449.2.1.1.2.3.41 | Scalarcdx6500NMNPSresetStatAll | write-only | mandatory | A value of reset will cause statistics to be reset on all ports. A value of noReset has no effect. |
| 1.3.6.1.4.1.449.2.1.1.2.3.42 | Scalarcdx6500NMNPSstatusPowerSy | read-only | mandatory | The operational status of the power supply. This object replaces cdx6500NMNPSstatusPwrSy. |
| 1.3.6.1.4.1.449.2.1.1.2.3.43 | Tablecdx6500NMNPSstatsTable | not-accessible | optional | Board specific statistics. Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.43.1 | Rowcdx6500NMNPSstatsEntry | not-accessible | optional | A Board statistics Table entry. Each entry contains statistics parameters for a single board. Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.43.1.1 | Columncdx6500NMNPSstatsBoard | read-only | optional | Board number. Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.43.1.2 | Columncdx6500NMNPSstatsbuffDataAvail | read-only | optional | The number of data buffers available. Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.43.1.3 | Columncdx6500NMNPSstatsbuffDataUse | read-only | optional | The number of data buffers in use. Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.43.1.4 | Columncdx6500NMNPSstatsbuffDataGauge | read-only | optional | The maximum number of data buffers in use since last reset Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.43.1.5 | Columncdx6500NMNPSstatsmemEprom | read-only | optional | Amount of memory available on the processor card in bytes. Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.43.1.6 | Columncdx6500NMNPSstatsmemDram | read-only | optional | Amount of memory used for data buffers in bytes. Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.43.1.7 | Columncdx6500NMNPSstatsmemFlash | read-only | optional | The size of the flash module in bytes. This refers to the currently selected bank of flash when there is an alternate bank of flash installed. Applicable to 65… |
| 1.3.6.1.4.1.449.2.1.1.2.3.43.1.8 | Columncdx6500NMNPSstatscpuUtil | read-only | optional | Percentage of time the CPU processed traffic data (as opposed performing diagnositic tests or processing node control data) to in the last 64 seconds. Applicab… |
| 1.3.6.1.4.1.449.2.1.1.2.3.43.1.9 | Columncdx6500NMNPSstatsMaxcpuUtil | read-only | optional | Peak CPU Utilization since last node or statistics reset. Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.43.1.10 | Columncdx6500NMNPSstatsMaxcpuUtilTime | read-only | optional | Time stamp of Peak CPU Utilization since last node or statistics reset. Applicable to 6500 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.44 | Scalarcdx6500NMNPScallsInPlaceMaxTime | read-only | mandatory | Time stamp of Max number of calls since the last reset. |
| 1.3.6.1.4.1.449.2.1.1.2.3.45 | Scalarcdx6500NMNPSPVCConnectMaxTime | read-only | mandatory | Time stamp of Max number of PVC connections since the last reset. |
| 1.3.6.1.4.1.449.2.1.1.2.3.46 | Scalarcdx6500NMNPScallsPerSecMaxTime | read-only | mandatory | Time stamp of Max number of calls/sec since the last reset. |
| 1.3.6.1.4.1.449.2.1.1.2.3.47 | Scalarcdx6500NMNPSbuffDataGaugeTime | read-only | optional | Time stamp of Max number of data buffers in use since the last reset. Applicable to all platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.48 | Scalarcdx6500NMNPSbuffPacketGauge | read-only | optional | The maximum number of packet buffers in use since the last reset. Applicable to all platforms except VG100. |
| 1.3.6.1.4.1.449.2.1.1.2.3.49 | Scalarcdx6500NMNPSbuffPacketGaugeTime | read-only | optional | Time stamp of Max number of packet buffers in use since the last reset. Applicable to all platforms except VG100. |
| 1.3.6.1.4.1.449.2.1.1.2.3.50 | Scalarcdx6500NMNPSbuffMgtGauge | read-only | optional | The maximum number of management buffers in use since the last reset. Applicable to all platforms except VG100. |
| 1.3.6.1.4.1.449.2.1.1.2.3.51 | Scalarcdx6500NMNPSbuffMgtGaugeTime | read-only | optional | Time stamp of Max number of management buffers in use since the last reset. Applicable to all platforms except VG100. |
| 1.3.6.1.4.1.449.2.1.1.2.3.52 | Scalarcdx6500NMNPSrateMaxCharTime | read-only | mandatory | Time stamp of Max node throughput (chars/sec) since the last reset. |
| 1.3.6.1.4.1.449.2.1.1.2.3.53 | Scalarcdx6500NMNPSrateMaxPktTime | read-only | mandatory | Time stamp of Max node throughput (packets/sec) since the last reset. |
| 1.3.6.1.4.1.449.2.1.1.2.3.54 | Scalarcdx6500NMNPSMaxcpuUtil | read-only | optional | Peak CPU Utilization since last node or statistics reset. Applicable to 6520 platforms. |
| 1.3.6.1.4.1.449.2.1.1.2.3.55 | Scalarcdx6500NMNPSMaxcpuUtilTime | read-only | optional | Time stamp of Peak CPU Utilization since last node or statistics reset. Applicable to 6520 platforms. |
| 1.3.6.1.4.1.449.2.1.1.3 | Nodecdx6500NMDiagnosticsGroup | |||
| 1.3.6.1.4.1.449.2.1.1.3.1 | Tablecdx6500NMReportTable | not-accessible | mandatory | All of the statistics parameters relevant to the Report event log table. |
| 1.3.6.1.4.1.449.2.1.1.3.1.1 | Rowcdx6500NMReportEntry | not-accessible | mandatory | A row of Report Statistics parameters. |
| 1.3.6.1.4.1.449.2.1.1.3.1.1.1 | Columncdx6500reptIndex | not-accessible | mandatory | Report Log Index |
| 1.3.6.1.4.1.449.2.1.1.3.1.1.2 | Columncdx6500reptEvent | read-only | mandatory | Report Log Alarm Text |
| 1.3.6.1.4.1.449.2.1.1.3.2 | Scalarcdx6500NMreptClearLog | write-only | mandatory | Clears the Operator log. clearLog - Clear the Log noClearLog - Do not clear the Log. |
| 1.3.6.1.4.1.449.2.1.1.3.3 | Nodecdx6500NMV54Loopback | |||
| 1.3.6.1.4.1.449.2.1.1.3.3.1 | Scalarcdx6500NMV54LocalLoop | write-only | obsolete | Local loop test; The test will start when set to value 'startTest'. |
| 1.3.6.1.4.1.449.2.1.1.3.3.2 | Scalarcdx6500NMV54Loop2 | write-only | obsolete | Loopback test 2 : Loop at remote modem digital side. |
| 1.3.6.1.4.1.449.2.1.1.3.3.3 | Scalarcdx6500NMV54Loop3 | write-only | obsolete | Loopback test 3: Loop at local modem analog side. |
| 1.3.6.1.4.1.449.2.1.1.3.3.4 | Scalarcdx6500NMV54turnLoopbackOff | write-only | obsolete | A control to turn any loopback test off |
| 1.3.6.1.4.1.449.2.1.1.3.3.5 | Scalarcdx6500NMV54LoopbackDuration | read-write | mandatory | Duration of loopback in seconds. |
| 1.3.6.1.4.1.449.2.1.1.3.3.6 | Scalarcdx6500NMV54TestType | read-only | obsolete | Loopback test type. |
| 1.3.6.1.4.1.449.2.1.1.3.3.7 | Scalarcdx6500NMV54LoopbackStatus | read-only | mandatory | Loopback Status. v54Starting - test is being prepared to start. v54Running - test in progress. v54Stopping - test is being stopped. v54Clearing - system is cle… |
| 1.3.6.1.4.1.449.2.1.1.3.3.9 | Scalarcdx6500NMV54MessagesSent | read-only | obsolete | Number of messages sent |
| 1.3.6.1.4.1.449.2.1.1.3.3.10 | Scalarcdx6500NMV54GoodMsgsReceived | read-only | obsolete | Number of good messages received |
| 1.3.6.1.4.1.449.2.1.1.3.3.11 | Scalarcdx6500NMV54BadMsgsReceived | read-only | obsolete | Number of bad messages received |
| 1.3.6.1.4.1.449.2.1.1.3.3.12 | Scalarcdx6500NMV54LastPortTested | read-only | obsolete | Last port to be put in loopback. |
| 1.3.6.1.4.1.449.2.1.1.3.3.13 | Scalarcdx6500NMV54CurrentTestPort | read-write | obsolete | Current test port. |
| 1.3.6.1.4.1.449.2.1.1.3.3.14 | Scalarcdx6500NMV54LoopbackTest | read-write | mandatory | Starts and stops loopback test. |
| 1.3.6.1.4.1.449.2.1.1.3.3.15 | Scalarcdx6500NMV54LoopbackTestType | read-write | mandatory | Loopback test type. v54LocalLoop - creates a loop on the selected port. v54Loop2 - creates a loop on the remote modem digital side. v54Loop3 - creates a loop o… |
| 1.3.6.1.4.1.449.2.1.1.3.3.16 | Scalarcdx6500NMV54LoopbackLastPortTested | read-only | mandatory | Last port put in loopback. |
| 1.3.6.1.4.1.449.2.1.1.3.3.17 | Scalarcdx6500NMV54LoopbackCurrentTestPort | read-write | mandatory | Current test port. Value zero means that no port has been specified. When test completes, this object is defaulted to zero. |
| 1.3.6.1.4.1.449.2.1.1.3.3.18 | Scalarcdx6500NMV54LoopbackMessagesSent | read-only | mandatory | Number of messages sent |
| 1.3.6.1.4.1.449.2.1.1.3.3.19 | Scalarcdx6500NMV54LoopbackGoodMsgsReceived | read-only | mandatory | Number of good messages received |
| 1.3.6.1.4.1.449.2.1.1.3.3.20 | Scalarcdx6500NMV54LoopbackBadMsgsReceived | read-only | mandatory | Number of bad messages received |
| 1.3.6.1.4.1.449.2.1.1.4 | Nodecdx6500NMControlsGroup | |||
| 1.3.6.1.4.1.449.2.1.1.4.1 | Scalarcdx6500NMCBootNode | write-only | mandatory | Setting this object will cuase the node to perform either a cold or a warm Node boot : bootCold - perform a cold Node Boot; run diagnostic tests, reload operat… |
| 1.3.6.1.4.1.449.2.1.1.4.2 | Scalarcdx6500NMCBootTableNodeRec | write-only | mandatory | Setting to bootrec will cause the running configuration to be updated using new configuration tables from CMEM. |
| 1.3.6.1.4.1.449.2.1.1.5 | Nodecdx6500NMDLSVGroup | |||
| 1.3.6.1.4.1.449.2.1.1.5.1 | Scalarcdx6500DLSVDLstate | read-only | mandatory | Statistic - state of the download dlStart : Setup phase. dlCall : Setup phase. dlReq : Setup phase. dlLoad : Downloading phase. dlGss : Setup phase. dlLgs : Do… |
| 1.3.6.1.4.1.449.2.1.1.5.2 | Scalarcdx6500DLSVPercentComplete | read-only | mandatory | Statistic - amount of download that has completed. |
| 1.3.6.1.4.1.449.2.1.1.5.3 | Scalarcdx6500DLSVTimestamp | read-only | mandatory | Statistic - time of last download. |
| 1.3.6.1.4.1.449.2.1.1.5.4 | Scalarcdx6500DLSVLastServer | read-only | mandatory | Statistic - Last server node to send software. |
| 1.3.6.1.4.1.449.2.1.1.5.5 | Scalarcdx6500DLSVTransferType | read-only | mandatory | Statistic - type of transfer - i.e. which bank to which bank at what throughput. |
| 1.3.6.1.4.1.449.2.1.1.5.6 | Scalarcdx6500DLSVInitiateTransfer | write-only | mandatory | Type of transfer - i.e. which bank to which bank at what throughput setting this initiates the flash to flash transfer. |
| 1.3.6.1.4.1.449.2.1.1.5.7 | Scalarcdx6500DLSVAgntSegmentSize | read-only | mandatory | This is the segment size used for accounting purposes with data packets. segmentSizeDisable - segment counting disabled. segmentSize16 - 16 byte segments. segm… |
| 1.3.6.1.4.1.449.2.1.1.5.8 | Scalarcdx6500DLSVAgntnmServAddress | read-only | mandatory | This is the mnemonic name of the download server assigned to load this node with operational software. |
| 1.3.6.1.4.1.449.2.1.1.5.9 | Scalarcdx6500DLSVagntloaderSubaddress | read-only | mandatory | This is the subaddress of the download module in this node. |
| 1.3.6.1.4.1.449.2.1.1.5.10 | Scalarcdx6500DLSVagntdlServSubaddress | read-only | mandatory | Calls with network address composed of the node address (configured in the Node record) and this subaddress will be routed to the module in this node which sen… |
| 1.3.6.1.4.1.449.2.1.2 | Nodecdx6500Configuration | |||
| 1.3.6.1.4.1.449.2.1.2.1 | Nodecdx6500CfgProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1 | Nodecdx6500PCTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.9 | Tablecdx6500CreatePortAndStationTable | not-accessible | mandatory | Create Port and Station table. |
| 1.3.6.1.4.1.449.2.1.2.1.9.1 | Rowcdx6500CreatePortAndStationEntry | not-accessible | mandatory | Entry for representing Creating Port and Station Record. |
| 1.3.6.1.4.1.449.2.1.2.1.9.1.1 | Columncdx6500PortNumber | read-only | mandatory | Port Number which is installed. |
| 1.3.6.1.4.1.449.2.1.2.1.9.1.2 | Columncdx6500CreatePortType | write-only | mandatory | port type to be created. pad : PAD port x25 : X25 port mx25 : Multipoint X25 port sdlc : Synchronous Data Link Control Port xdlc : X25 Data Link Control Port f… |
| 1.3.6.1.4.1.449.2.1.2.1.9.1.3 | Columncdx6500CreateStation | write-only | mandatory | station number to be created. The instance should be existing port number. Station Range : 1 - Max Station Number. |
| 1.3.6.1.4.1.449.2.1.2.2 | Nodecdx6500CfgGeneralGroup | |||
| 1.3.6.1.4.1.449.2.1.2.2.1 | Tablecdx6500GCTRouteSelectionTable | not-accessible | mandatory | A list of Configuration Parameters that select the links over which calls are routed. |
| 1.3.6.1.4.1.449.2.1.2.2.1.1 | Rowcdx6500GCTRouteSelectionEntry | not-accessible | mandatory | Each entry contains a list of parameters that makeup the Route Selection Table. |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.1 | Columncdx6500RoutSVCEntryNumber | read-only | mandatory | This is not a configurable parameter. This identifies the particular Route Selection Table entry being configured by the other parameters in the record. |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.2 | Columncdx6500RoutSVCAddress | read-only | deprecated | This is a non-supported object. It has been replaced by cdx6500RoutSVCAddress1. |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.3 | Columncdx6500RoutSVCDestination1 | read-write | mandatory | This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. B… |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.4 | Columncdx6500RoutSVCPriority1 | read-write | mandatory | This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load … |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.5 | Columncdx6500RoutSVCDestination2 | read-write | mandatory | This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. B… |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.6 | Columncdx6500RoutSVCPriority2 | read-write | mandatory | This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load … |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.7 | Columncdx6500RoutSVCDestination3 | read-write | mandatory | This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. B… |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.8 | Columncdx6500RoutSVCPriority3 | read-write | mandatory | This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load … |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.9 | Columncdx6500RoutSVCDestination4 | read-write | mandatory | This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. B… |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.10 | Columncdx6500RoutSVCPriority4 | read-write | mandatory | This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load … |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.11 | Columncdx6500RoutSVCDestination5 | read-write | mandatory | This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. B… |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.12 | Columncdx6500RoutSVCPriority5 | read-write | mandatory | This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load … |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.13 | Columncdx6500RoutSVCDestination6 | read-write | mandatory | This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. B… |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.14 | Columncdx6500RoutSVCPriority6 | read-write | mandatory | This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load … |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.15 | Columncdx6500RoutSVCDestination7 | read-write | mandatory | This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. B… |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.16 | Columncdx6500RoutSVCPriority7 | read-write | mandatory | This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load … |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.17 | Columncdx6500RoutSVCDestination8 | read-write | mandatory | This specifies the network address to which calls are routed. For example: BCST route calls to the broadcast module. BSC2780-4 route calls to BSC2780 port 4. B… |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.18 | Columncdx6500RoutSVCPriority8 | read-write | mandatory | This specifies the priority for call forwarding to ports within the Route Selection Table. Call forwarding is determined by a combination of priority and load … |
| 1.3.6.1.4.1.449.2.1.2.2.1.1.19 | Columncdx6500RoutSVCAddress1 | read-write | mandatory | Network address for calls routed beyond this node. A route selection entry is not needed for calls destined within this node: PAD port or node resource (for ex… |
| 1.3.6.1.4.1.449.2.1.2.2.5 | Tablecdx6500GCTPVCSetupTable | not-accessible | mandatory | A list of Configuration Parameters for PVCs. |
| 1.3.6.1.4.1.449.2.1.2.2.5.1 | Rowcdx6500GCTPVCSetupEntry | not-accessible | mandatory | Each entry contains a PVC source and PVC destination. |
| 1.3.6.1.4.1.449.2.1.2.2.5.1.1 | Columncdx6500PVCSetupEntryNumber | read-only | mandatory | This is not a configurable parameter. This identifies the particular PVC Table entry being configured by the other parameters in the record. |
| 1.3.6.1.4.1.449.2.1.2.2.5.1.2 | Columncdx6500PVCSetupSource | read-write | mandatory | This is the PVC source channel identifier. Entries are not case sensitive. For example: BCST route calls to the broadcast module. MX25-2s3(2) route calls to MX… |
| 1.3.6.1.4.1.449.2.1.2.2.5.1.3 | Columncdx6500PVCSetupDestination | read-write | mandatory | This is the PVC destination channel identifier. Entries are not case sensitive. For example: BCST route calls to the broadcast module. MX25-2s3(2) route calls … |
| 1.3.6.1.4.1.449.2.1.2.2.6 | Tablecdx6500CfgMnemonicTable | not-accessible | mandatory | All of the configuration parameters relevant to the Mnemonic table. |
| 1.3.6.1.4.1.449.2.1.2.2.6.1 | Rowcdx6500CfgMnemonicEntry | not-accessible | mandatory | A row of mnemonic configuration parameters. |
| 1.3.6.1.4.1.449.2.1.2.2.6.1.1 | Columncdx6500mnemEntryNum | read-only | mandatory | This is not a configuration parameter. Instead, it identifies the particular Mnemonic Table entry being configured by the other parameters in the record. NOTE:… |
| 1.3.6.1.4.1.449.2.1.2.2.6.1.2 | Columncdx6500mnemName | read-only | mandatory | This is an mnemonic name available to PAD port users for abbreviated calling or autocalling. The following parameter will specify call details. The mnemonic CT… |
| 1.3.6.1.4.1.449.2.1.2.2.6.1.3 | Columncdx6500mnemx28Cmd | read-only | mandatory | This specifies call details for the mnemonic configured in the previous parameter. Use the format of an X.28 call command, but leave out the command specifier … |
| 1.3.6.1.4.1.449.2.1.2.2.7 | Tablecdx6500GCTNUIPasswordTable | not-accessible | mandatory | A list of NUI/Password configuration entries. |
| 1.3.6.1.4.1.449.2.1.2.2.7.1 | Rowcdx6500GCTNUIPasswordEntry | not-accessible | mandatory | The Network User Identification (NUI)/Password Table. |
| 1.3.6.1.4.1.449.2.1.2.2.7.1.1 | Columncdx6500NUITEntryNumber | read-only | mandatory | This is not a configurable parameter. Instead, it identifies the particular NUI/Password Table entry being configured by the other parameters in the record. |
| 1.3.6.1.4.1.449.2.1.2.2.7.1.2 | Columncdx6500NUITAcctName | read-only | mandatory | This is the account name for billing records. |
| 1.3.6.1.4.1.449.2.1.2.2.7.1.3 | Columncdx6500NUITPasswd | read-only | mandatory | This is the password for the account name. |
| 1.3.6.1.4.1.449.2.1.2.2.7.1.4 | Columncdx6500NUITPADPromptNum | read-only | mandatory | This parameter specifies which entry in the PAD Prompt Table is used as a PAD prompt after the user has entered a valid password. Use 0 for standard asterisk p… |
| 1.3.6.1.4.1.449.2.1.2.2.12 | Tablecdx6500GCTSoftwareKeyTable | not-accessible | mandatory | A table of Software Key configuration entries. |
| 1.3.6.1.4.1.449.2.1.2.2.12.1 | Rowcdx6500GCTSoftwareKeyEntry | not-accessible | mandatory | The Software Key for a specific optional software product code. |
| 1.3.6.1.4.1.449.2.1.2.2.12.1.1 | Columncdx6500CSISSoftKeyEntryNumber | read-only | mandatory | This is not a configurable parameter. It is the reference number for the individual software option that is being enabled. You must configure a separate entry … |
| 1.3.6.1.4.1.449.2.1.2.2.12.1.2 | Columncdx6500CSISSoftKeyValue | read-only | mandatory | This is a software key supplied by Codex Corporation for this node. |
| 1.3.6.1.4.1.449.2.1.3 | Nodecdx6500Statistics | |||
| 1.3.6.1.4.1.449.2.1.3.1 | Nodecdx6500StatProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1 | Nodecdx6500PSTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1.18 | Tablecdx6500PPSTallPortsTable | not-accessible | mandatory | All of the statistics parameters relevant to the allPorts table. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1 | Rowcdx6500PPSTallPortsEntry | not-accessible | mandatory | A row of allPorts statistics parameters. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.1 | Columncdx6500allportsPortNum | read-only | mandatory | Number of the port |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.2 | Columncdx6500allportsPortType | read-only | mandatory | Type of port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.3 | Columncdx6500allportsPortStatus | read-only | mandatory | Status of the port. disabled - Port is disabled. enabled - Port is enabled. busyOut - Port is busyOuted. up - Port is up. down - Port is down. newvalDisabled -… |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.4 | Columncdx6500allportsPortState | read-only | mandatory | Current Port state. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.5 | Columncdx6500allportsPortSpeed | read-only | mandatory | This is the speed of the port when Clock=Int; this is detected clock speed if Clock=Ext. If Port Speed is 0, Clock=Ext then clocking is not being received from… |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.6 | Columncdx6500allportsUtilizationIn | read-only | mandatory | Percentage of port bandwidth in use. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.7 | Columncdx6500allportsUtilizationOut | read-only | mandatory | Percentage of port bandwidth in use. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.8 | Columncdx6500allportsCharInTot | read-only | mandatory | Number of characters received by the port since the last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.9 | Columncdx6500allportsCharOutTot | read-only | mandatory | Number of characters sent by the port since the last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.10 | Columncdx6500allportsPktInTot | read-only | mandatory | Number of packets received by the port since the last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.11 | Columncdx6500allportsPktOutTot | read-only | mandatory | Number of packets sent by the port since the last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.12 | Columncdx6500allportsFrameInTot | read-only | mandatory | Number of frames received by the port since the last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.13 | Columncdx6500allportsFrameOutTot | read-only | mandatory | Number of frames sent by the port since the last node, port or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.14 | Columncdx6500allportsPktsQueued | read-only | mandatory | Number of packets currently queued. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.15 | Columncdx6500allportsCharsInPerSec | read-only | mandatory | Summary of the characters being received over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.16 | Columncdx6500allportsCharsOutPerSec | read-only | mandatory | Summary of the characters being sent over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.17 | Columncdx6500allportsPktsInPerSec | read-only | mandatory | Summary of the packets being received over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.18 | Columncdx6500allportsPktsOutPerSec | read-only | mandatory | Summary of the packets being sent over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.19 | Columncdx6500allportsFramesInPerSec | read-only | mandatory | Summary of the frames being received over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.20 | Columncdx6500allportsFramesOutPerSec | read-only | mandatory | Summary of the frames being sent over the port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.21 | Columncdx6500allportsOverrunErrors | read-only | mandatory | Number of Overrun errors since the last node or statistics reset. Overrun Errors: Received data was lost because it could not be processed by the CPU. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.22 | Columncdx6500allportsUnderrunErrors | read-only | mandatory | Number of Underrun errors since the last node or statistics reset. UnderrunErrors: Transmission of a frame could not be completed because all the data had not … |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.23 | Columncdx6500allportsCRCErrors | read-only | mandatory | Number of CRC errors since the last node or statistics reset. CRC Errors: Cyclical Redundancy failure because of noise on the line. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.24 | Columncdx6500allportsParityErrors | read-only | mandatory | Number of Parity errors since the last reset |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.25 | Columncdx6500allportsFramingErrors | read-only | mandatory | Number of Framing errors since the last reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.26 | Columncdx6500allportsBootPort | write-only | mandatory | Boots the specified Port. bootPort - Boot the Port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.18.1.27 | Columncdx6500allportsPortControlStatus | write-only | mandatory | Change the Port Control Status. enable - Enable the Port. disable - Disable the Port. busyout - BusyOut the Port. |
| 1.3.6.1.4.1.449.2.1.3.1.3 | Nodecdx6500PSTStationProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.3.8 | Tablecdx6500SPSTallStationsTable | not-accessible | mandatory | All of the statistics parameters relevant to the allStations table. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1 | Rowcdx6500SPSTallStationsEntry | not-accessible | mandatory | A row of allStations statistics parameters. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.1 | Columncdx6500allstationsPortNum | read-only | mandatory | Number of the port. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.2 | Columncdx6500allstationsStnNum | read-only | mandatory | Number of the station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.3 | Columncdx6500allstationsStnType | read-only | mandatory | Type of station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.4 | Columncdx6500allstationsStnStatus | read-only | mandatory | Status of the station. disabled - Station is disabled. enabled - Station is enabled. busyOut - Station is busyOuted. up - Station is up. down - Station is down… |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.5 | Columncdx6500allstationsStnState | read-only | mandatory | Current Station state. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.6 | Columncdx6500allstationsUtilizationIn | read-only | mandatory | Percentage of station bandwidth in use. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.7 | Columncdx6500allstationsUtilizationOut | read-only | mandatory | Percentage of station bandwidth in use. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.8 | Columncdx6500allstationsCharInTot | read-only | mandatory | Number of characters received by the station since the last node, port, station or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.9 | Columncdx6500allstationsCharOutTot | read-only | mandatory | Number of characters sent by the station since the last node, port, station or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.10 | Columncdx6500allstationsPktInTot | read-only | mandatory | Number of packets received by the station since the last node, port, station or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.11 | Columncdx6500allstationsPktOutTot | read-only | mandatory | Number of packets sent by the port since the last node, port, station or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.12 | Columncdx6500allstationsFrameInTot | read-only | mandatory | Number of frames received by the port since the last node, port, station or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.13 | Columncdx6500allstationsFrameOutTot | read-only | mandatory | Number of frames sent by the port since the last node, port, station or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.14 | Columncdx6500allstationsPktsQueued | read-only | mandatory | Number of packets currently queued. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.15 | Columncdx6500allstationsCharsInPerSec | read-only | mandatory | Summary of the characters being received over the station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.16 | Columncdx6500allstationsCharsOutPerSec | read-only | mandatory | Summary of the characters being sent over the station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.17 | Columncdx6500allstationsPktsInPerSec | read-only | mandatory | Summary of the packets being received over the station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.18 | Columncdx6500allstationsPktsOutPerSec | read-only | mandatory | Summary of the packets being sent over the station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.19 | Columncdx6500allstationsFramesInPerSec | read-only | mandatory | Summary of the frames being received over the station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.20 | Columncdx6500allstationsFramesOutPerSec | read-only | mandatory | Summary of the frames being sent over the station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.21 | Columncdx6500allstationsBootStation | write-only | mandatory | Boots the specified station. bootStn - Boot Station noBootStn - Do not boot Station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.22 | Columncdx6500allstationsDisableStation | write-only | mandatory | Disables the specified station. disableStn - Disable Station. noDisableStn - Do not disable Station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.23 | Columncdx6500allstationsEnableStation | write-only | mandatory | Enables the specified station. enableStn - Enable Station. noEnableStn - Not not enable Station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.8.1.24 | Columncdx6500allstationsBusyOutStation | write-only | mandatory | Busy out the specified station. busyoutStn - Busyout Station. noBusyoutStn - Do not busyout Station. |
| 1.3.6.1.4.1.449.2.1.3.1.6 | Nodecdx6500PSTLANConnectionGroup | |||
| 1.3.6.1.4.1.449.2.1.3.2 | Nodecdx6500StatOtherStatsGroup | |||
| 1.3.6.1.4.1.449.2.1.3.2.5 | Tablecdx6500OSTCSISOptionStatTable | not-accessible | mandatory | A table describing the Software Options that have been purchased and enabled for this node. |
| 1.3.6.1.4.1.449.2.1.3.2.5.1 | Rowcdx6500OSTCSISOptionStatEntry | not-accessible | mandatory | A list of objects describing a single Software Option. |
| 1.3.6.1.4.1.449.2.1.3.2.5.1.1 | Columncdx6500CSISOptionNumber | read-only | mandatory | Table index, which is code for the software option. Following are the various software options and their codes. 1 - MX25 2 - SDLC 3 - BSC3270 4 - BSC2780 5 - V… |
| 1.3.6.1.4.1.449.2.1.3.2.5.1.2 | Columncdx6500CSISMaxAllowed | read-only | mandatory | Number of ports that this option can support. Options can be purchased to support different numbers of ports. Value of 65535 indicates no limit. |
| 1.3.6.1.4.1.449.2.1.3.2.5.1.3 | Columncdx6500CSISNumUsed | read-only | mandatory | The number of ports actually being used with this option. |
| 1.3.6.1.4.1.449.2.1.3.2.5.1.4 | Columncdx6500CSISOptionAuth | read-only | mandatory | unauthorized - an attempt was made to use an option that has not been purchased or enabled. authorized - all attempts to use the option were authorized. |
| 1.3.6.1.4.1.449.2.1.3.2.6 | Tablecdx6500OSTCSISPortUsageTable | not-accessible | mandatory | A table providing statistics on unauthorized port usage. |
| 1.3.6.1.4.1.449.2.1.3.2.6.1 | Rowcdx6500OSTCSISPortUsageEntry | not-accessible | mandatory | A list of authorization statistics for a single port. |
| 1.3.6.1.4.1.449.2.1.3.2.6.1.1 | Columncdx6500CSISPortNumber | read-only | mandatory | The port's number. |
| 1.3.6.1.4.1.449.2.1.3.2.6.1.2 | Columncdx6500CSISPortAuth | read-only | mandatory | unauthorized - an attempt was made to use this port to exceed an option port limit. authorized - the port was not used in an unauthorized fashion. |
| 1.3.6.1.4.1.449.2.1.3.3 | Nodecdx6500StatTFTPGroup | |||
| 1.3.6.1.4.1.449.2.1.3.4 | Nodecdx6500StatNetworkSvcsGroup | |||
| 1.3.6.1.4.1.449.2.1.3.4.1 | Tablecdx6500StatSVCTable | not-accessible | mandatory | A table of currently active switched virtual circuits (SVC). The table is dynamic i.e. changing as queries are being performed on the table. |
| 1.3.6.1.4.1.449.2.1.3.4.1.1 | Rowcdx6500StatSVCEntry | not-accessible | mandatory | A list of objects describing a single SVC. |
| 1.3.6.1.4.1.449.2.1.3.4.1.1.1 | Columncdx6500StatSVCIndex | read-only | mandatory | It is position in the list of SVC's. |
| 1.3.6.1.4.1.449.2.1.3.4.1.1.2 | Columncdx6500StatSVCCallingChannel | read-only | mandatory | Calling channel of SVC. |
| 1.3.6.1.4.1.449.2.1.3.4.1.1.3 | Columncdx6500StatSVCCalledChannel | read-only | mandatory | Called channel of SVC. |
| 1.3.6.1.4.1.449.2.1.3.4.1.1.4 | Columncdx6500StatSVCReverseCharge | read-only | mandatory | Reverse charge facility condition. refuse - Refused the condition. accept - Accepted the condition. newvalRefuse - same functionality as 'refuse', new enumerat… |
| 1.3.6.1.4.1.449.2.1.3.4.1.1.5 | Columncdx6500StatSVCFastSelect | read-only | mandatory | Fast select facility condition. noFastSelect - Fast select facility is not selected. fastSelect - Fast select facility is selected. newvalNoFastSelect - same f… |
| 1.3.6.1.4.1.449.2.1.3.4.1.1.6 | Columncdx6500StatSVCNetUserIdentification | read-only | mandatory | Net user identifiaction facility condition. notRequested - Net user identifiaction facility not requested. requested - Net user identifiaction facility request… |
| 1.3.6.1.4.1.449.2.1.3.4.1.1.7 | Columncdx6500StatSVCClosedUserGroup | read-only | mandatory | Closed user group facility on/off. notRequested - Closed user group facility off. requested - Closed user group facility on. newvalNotRequested - same function… |
| 1.3.6.1.4.1.449.2.1.3.4.1.1.8 | Columncdx6500StatSVCConnectionUPTime | read-only | mandatory | Time at which connection was up. |
| 1.3.6.1.4.1.449.2.1.4 | Nodecdx6500Controls | |||
| 1.3.6.1.4.1.449.2.1.4.2 | Nodecdx6500ContTFTP | |||
| 1.3.6.1.4.1.449.2.1.4.4 | Nodecdx6500statControls | |||
| 1.3.6.1.4.1.449.2.1.4.4.1 | Scalarcdx6500statResetAllStats | write-only | mandatory | A control object that when set to reset will cause the node to reset ALL its statistics. reset - reset ALL node statistics. noReset - Do not reset the statisti… |
| 1.3.6.1.4.1.449.2.1.4.21 | Nodecdx6500ContFlash | |||
| 1.3.6.1.4.1.449.2.1.4.21.1 | Scalarcdx6500ContFlashCopyImage | write-only | mandatory | Copy image from current to alternate or alternate to current. |
| 1.3.6.1.4.1.449.2.1.4.21.2 | Scalarcdx6500ContFlashCopyCmem | write-only | mandatory | Copy cmem from current to alternate or alternate to current. |
| 1.3.6.1.4.1.449.2.1.4.21.3 | Scalarcdx6500ContFlashActiveImage | write-only | mandatory | Activate image in flash memory. |
| 1.3.6.1.4.1.449.2.1.4.21.4 | Scalarcdx6500ContFlashActiveCmem | write-only | mandatory | Activate cmem in flash memory. |
| 1.3.6.1.4.1.449.2.1.4.21.5 | Scalarcdx6500ContFlashDeleteImage | write-only | mandatory | Delete all images in flash memory. |
| 1.3.6.1.4.1.449.2.1.4.23 | Nodecdx6500ContT3E3Table | |||
| 1.3.6.1.4.1.449.2.1.4.23.1 | Scalarcdx6500T3E3ContEntry | not-accessible | mandatory | Each control applies to a single T3E3 port. |
| 1.3.6.1.4.1.449.2.1.4.23.1.1 | Scalart3e3ContPortNumber | not-accessible | mandatory | Port number of the T3E3 port. |
| 1.3.6.1.4.1.449.2.1.4.23.1.2 | Scalart3e3ContPortControl | write-only | mandatory | Control operations for the specified T3E3 port. boot - Boots the T3E3 port enable - Enables the T3E3 port disable - Disables the T3E3 port resetstats - Resets … |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Counter16 | INTEGER (0..65535) | ||
| DisplayString | OCTET STRING |