MIB Viewer

CENTILLION-SYSTEM-EVENT-LOG-MIB

21 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.930.2.1.5.1ScalarsysEvtLogDurationread-writemandatoryThis value indicates the remaining duration of Event Logging. The unit is in seconds. The maximum value is equal to 1000 days (86,400,000 seconds). A set value…
1.3.6.1.4.1.930.2.1.5.2ScalarsysEvtLogPreFilterEntityMapread-writemandatoryThe bit array that contains the bit map of all possible entities for event logging pre-filter control. There are total of 64 entities. Each entity represented …
1.3.6.1.4.1.930.2.1.5.3ScalarsysEvtLogPreFilterSeverityread-writemandatoryThis value indicates the severity level for event log pre-filtering control. An event message with less severity level will not be logged into event message bu…
1.3.6.1.4.1.930.2.1.5.4TablesysEvtLogSlotPreFilterTablenot-accessiblemandatoryA slot table for controlling pre-filter setting for all slots. This table is managed by Event Log application only. Table entries cannot be created or deleted.
1.3.6.1.4.1.930.2.1.5.4.1RowsysEvtLogSlotPreFilterEntrynot-accessiblemandatoryAn entry of the slot pre-filter table.
1.3.6.1.4.1.930.2.1.5.4.1.1ColumnsysEvtLogSlotPreFilterCardIdread-onlymandatoryThe slot index varies by system. It is chassis dependent. For C100, valid number is 1-6. For BH left, valid number is 2-7. For BH right, valid number is 8-13. …
1.3.6.1.4.1.930.2.1.5.4.1.2ColumnsysEvtLogSlotPreFilterControlread-writemandatoryThis value indicates the pre-filter setting for the specified slot.
1.3.6.1.4.1.930.2.1.5.5TablesysEvtLogPortPreFilterTablenot-accessiblemandatoryA port table for controlling pre-filter setting for all ports. This table is managed by Event Log application only. Table entries cannot be created or deleted.
1.3.6.1.4.1.930.2.1.5.5.1RowsysEvtLogPortPreFilterEntrynot-accessiblemandatoryAn entry for port table for controlling pre-filter setting for all ports.
1.3.6.1.4.1.930.2.1.5.5.1.1ColumnsysEvtLogPortPreFilterCardIdread-onlymandatoryThe slot index varies by system. It is chassis dependent. For C100, valid number is 1-6. For BH left, valid number is 2-7. For BH right, valid number is 8-13. …
1.3.6.1.4.1.930.2.1.5.5.1.2ColumnsysEvtLogPortPreFilterPortIdread-onlymandatoryThe port index of the specified slot.
1.3.6.1.4.1.930.2.1.5.5.1.3ColumnsysEvtLogPortPreFilterControlread-writemandatoryThis value indicates the pre-filter setting for the specified port. Note: A module must be properly configured before any port of the module can be set with a …
1.3.6.1.4.1.930.2.1.5.6ScalarsysEvtLogDestMapread-writemandatoryThis value is a bit map of each destination that Event Log can forward messages to, where bit 0 for console CLI bit 1 for Syslogd bit 2 for Tftpsave The value …
1.3.6.1.4.1.930.2.1.5.7NodesysEvtLogSysLogCfg
1.3.6.1.4.1.930.2.1.5.7.1ScalarsysEvtLogSysLogHostIpread-writemandatoryThe IP address of Unix system that runs Syslogd. The event messages are redirect to Syslogd only when this IP address is valid and the bit value of Syslogd of …
1.3.6.1.4.1.930.2.1.5.7.2ScalarsysEvtLogSysLogSeverityread-writemandatoryThis value indicates the severity level for Event Log to forward events to SysLogd in Unix system. An event message with less severity level will not be forwar…
1.3.6.1.4.1.930.2.1.5.7.3ScalarsysEvtLogSysLogFacilityread-writemandatoryThis value indicates the facility number for the event messages to be logged by syslogd. The supported values are from local0 to local7 only (refer to syslogd …
1.3.6.1.4.1.930.2.1.5.8NodesysEvtLogTftpsaveCfg
1.3.6.1.4.1.930.2.1.5.8.1ScalarsysEvtLogTftpsaveHostIpread-writemandatoryThe IP address of TFTP server system. The event messages file is transfered from event log buffer to server system only when this IP is valid and the event mes…
1.3.6.1.4.1.930.2.1.5.8.2ScalarsysEvtLogTftpsaveFileNameread-writemandatoryThis octet string indicates the file name for the Tftpsave option of event log function. The filename will be appended with an extension nnn, where nnn ranges …
1.3.6.1.4.1.930.2.1.5.8.3ScalarsysEvtLogTftpsaveMaxMsgCountread-writemandatoryThis value indicates how many messages in the event log buffer will trigger the TFTP file transfer for logged messages to TFTP host. the default value is maxim…