MIB Viewer

CIRCUIT-MIB

80 objects
The MIB module for transport channels
OIDNameAccessStatusDescription
1.3.6.1.4.1.5812.6.1IdentitycircuitMIBThe MIB module for transport channels
1.3.6.1.4.1.5812.6.2ScalarcircuitLoadBalanceIntervalread-writecurrentThe default load balancing schedule is to examine 1 circuit every 3 minutes at the GNE. Regardless of whether the circuit is moved to a better ring path or not…
1.3.6.1.4.1.5812.6.3ScalarcircuitLoadBalanceNumPerIntervalread-writecurrentIndicates the number of circuits being loadbalanced in a fixed interval. The maximum value is 10 circuits per second.
1.3.6.1.4.1.5812.6.4ScalarcircuitOldIpAddrToSwapread-writecurrentWhen a chassis running several circuits has to be moved to a new location with a new different IpAddress, then all the associated circuits has to be properly m…
1.3.6.1.4.1.5812.6.5ScalarcircuitNewIpAddrToSwapread-writecurrentWhen a chassis running several circuits has to be moved to a new location with a new different IpAddress, then all the associated circuits has to be properly m…
1.3.6.1.4.1.5812.6.6ScalarcircuitEventIntervalread-writecurrentFor any circuit related events, events are generated at a specific time interval. circuitEventInterval specifies that. The default value is 1 second.
1.3.6.1.4.1.5812.6.7ScalarcircuitEventNumPerIntervalread-writecurrentThis object specifies the number of events generated per interval. The default is 10 per second.
1.3.6.1.4.1.5812.6.8TablecircuitTablenot-accessiblecurrentA table containing information about the transport channels in the system
1.3.6.1.4.1.5812.6.8.1RowcircuitEntrynot-accessiblecurrentEntry in the table for a single transport channel
1.3.6.1.4.1.5812.6.8.1.1ColumncircuitSrcIpAddrread-writecurrentIP address of the source circuit endpoint.
1.3.6.1.4.1.5812.6.8.1.2ColumncircuitSrcInterfaceNumread-writecurrentThe interface number of the source circuit endpoint.
1.3.6.1.4.1.5812.6.8.1.3ColumncircuitSrcConnectionIDread-writecurrentConnection Identifier of the source circuit endpoint. Based on the protocol type, further information may be required to completely specify a circuit on a chan…
1.3.6.1.4.1.5812.6.8.1.4ColumncircuitSrcDescStringread-onlycurrentTextual description of the source side of the circuit endpoint.
1.3.6.1.4.1.5812.6.8.1.5ColumncircuitDestIpAddrread-writecurrentIP address of the destination circuit endpoint.
1.3.6.1.4.1.5812.6.8.1.6ColumncircuitDestInterfaceNumread-writecurrentThe interface number of the destination circuit endpoint.
1.3.6.1.4.1.5812.6.8.1.7ColumncircuitDestConnectionIDread-writecurrentConnection Identifier of the destination circuit endpoint. Based on the protocol type, further information may be required to completely specify a circuit on a…
1.3.6.1.4.1.5812.6.8.1.8ColumncircuitDestDescStringread-onlycurrentTextual description of the destination side of the circuit endpoint.
1.3.6.1.4.1.5812.6.8.1.9ColumncircuitNameread-writecurrentCircuitName is a unique name given to a circuit.
1.3.6.1.4.1.5812.6.8.1.10ColumncircuitIDread-onlycurrentCircuitID is a unique ID given to a circuit. It is equal to the TC-ID in the PM.
1.3.6.1.4.1.5812.6.8.1.11ColumncircuitRowStatusread-writecurrentIndicates if a row has been created or deleted. See SNMPv2-TC for complete description.
1.3.6.1.4.1.5812.6.8.1.12ColumncircuitReasonTextread-onlycurrentProvides the reason for the error indicated.
1.3.6.1.4.1.5812.6.8.1.13ColumncircuitFailLocIpAddrread-onlycurrentIP address of location where circuit failure code is encountered.
1.3.6.1.4.1.5812.6.8.1.14ColumncircuitFailLocSlot1read-onlycurrentSlot number where circuit failure code is encountered.
1.3.6.1.4.1.5812.6.8.1.15ColumncircuitFailLocPort1read-onlycurrentPort number where circuit failure code is encountered.
1.3.6.1.4.1.5812.6.8.1.16ColumncircuitFailLocInterfaceNum1read-onlycurrentInterface number where circuit failure code is encountered.
1.3.6.1.4.1.5812.6.8.1.17ColumncircuitFailLocConnectionID1read-onlycurrentConnection Identifier of the failed circuit endpoint.
1.3.6.1.4.1.5812.6.8.1.18ColumncircuitFailLocSlot2read-onlycurrentSlot number where circuit failure code is encountered.
1.3.6.1.4.1.5812.6.8.1.19ColumncircuitFailLocPort2read-onlycurrentPort number where circuit failure code is encountered.
1.3.6.1.4.1.5812.6.8.1.20ColumncircuitFailLocInterfaceNum2read-onlycurrentInterface number where circuit failure code is encountered.
1.3.6.1.4.1.5812.6.8.1.21ColumncircuitFailLocConnectionID2read-onlycurrentConnection Identifier of the failed circuit endpoint.
1.3.6.1.4.1.5812.6.8.1.22ColumncircuitEndPoint1Protocolread-writecurrentProtocol determines the connectionID.
1.3.6.1.4.1.5812.6.8.1.23ColumncircuitFwdTDTyperead-writecurrentSpecifies the traffic descriptor type associated with the forward traffic descriptor parameters. The forward direction is 'into the network' from the circuit e…
1.3.6.1.4.1.5812.6.8.1.24ColumncircuitFwdTDParam1read-writecurrentParameter 1 of the forward traffic descriptor of type circuitFwdTdType. For type Ethernet, this value corresponds to CIR. For type Frame Relay, this value corr…
1.3.6.1.4.1.5812.6.8.1.25ColumncircuitFwdTDParam2read-writecurrentParameter 2 of the forward traffic descriptor of type circuitFwdTdType. For type Ethernet, this value corresponds to Bc. For type Frame Relay, this value corre…
1.3.6.1.4.1.5812.6.8.1.26ColumncircuitFwdTDParam3read-writecurrentParameter 3 of the forward traffic descriptor of type circuitFwdTdType. For type Ethernet, this value corresponds to Be. For type Frame Relay, this value corre…
1.3.6.1.4.1.5812.6.8.1.27ColumncircuitFwdTDParam4read-writecurrentParameter 4 of the forward traffic descriptor of type circuitFwdTdType.
1.3.6.1.4.1.5812.6.8.1.28ColumncircuitEndPoint2Protocolread-writecurrentProtocol determines the connectionID.
1.3.6.1.4.1.5812.6.8.1.29ColumncircuitBwdTDTyperead-writecurrentSpecifies the traffic descriptor type associated with the backward traffic descriptor parameters. The backward direction is 'out of the network' from the circu…
1.3.6.1.4.1.5812.6.8.1.30ColumncircuitBwdTDParam1read-writecurrentParameter 1 of the backward traffic descriptor of type circuitBwdTdType. For type Ethernet, this value corresponds to CIR. For type Frame Relay, this value cor…
1.3.6.1.4.1.5812.6.8.1.31ColumncircuitBwdTDParam2read-writecurrentParameter 2 of the backward traffic descriptor of type circuitBwdTdType. For type Ethernet, this value corresponds to Bc. For type Frame Relay, this value corr…
1.3.6.1.4.1.5812.6.8.1.32ColumncircuitBwdTDParam3read-writecurrentParameter 3 of the backward traffic descriptor of type circuitBwdTdType. For type Ethernet, this value corresponds to Be. For type Frame Relay, this value corr…
1.3.6.1.4.1.5812.6.8.1.33ColumncircuitBwdTDParam4read-writecurrentParameter 4 of the backward traffic descriptor of type circuitBwdTdType.
1.3.6.1.4.1.5812.6.8.1.34ColumncircuitClassOfServiceread-writecurrentSpecifies the class of service for Data or non-TDM circuits. This value is in the range of 0-7 where 1 has the highest priority and 7 has the lowest.
1.3.6.1.4.1.5812.6.8.1.35ColumncircuitAdminStateread-writecurrentAdministrative state of the circuit. Circuits in the disabled state do not consume network resources such as bandwidth. The network continuously attempts to es…
1.3.6.1.4.1.5812.6.8.1.36ColumncircuitOperStateread-onlycurrentAperational state of the circuit. Circuits in the disabled state do not consume network resources such as bandwidth. The network continuously attempts to estab…
1.3.6.1.4.1.5812.6.8.1.37ColumncircuitTimeSinceStatusChangeread-onlycurrentGives the time (in seconds) since the most recent status change.
1.3.6.1.4.1.5812.6.8.1.38ColumncircuitSetupPriorityread-onlycurrentIf there are insufficient network resources for establishing all transport channels, this field specifies the priority of the transport channel.
1.3.6.1.4.1.5812.6.8.1.39ColumncircuitHoldPriorityread-onlycurrentIf a number of transport channels of a low Setup Priority need to be cleared in order to release resources allowing for a higher priority (Setup) transport cha…
1.3.6.1.4.1.5812.6.8.1.40ColumncircuitIsRedundancyReqdread-writecurrentSpecifies if the circuit is to be established over rings that are logically configured as 'protected'. A protected ring could physically be in a fault state wh…
1.3.6.1.4.1.5812.6.8.1.41ColumncircuitPreferredEP1OptSlotread-writecurrentIf the circuit spans one or two rings, this is the slot number of the first preferred ring. Preferred rings allow a manual overide of the routed circuit path.
1.3.6.1.4.1.5812.6.8.1.42ColumncircuitPreferredEP1OptPortread-writecurrentIf the circuit spans one or two rings, this is the port number of the first preferred ring.
1.3.6.1.4.1.5812.6.8.1.43ColumncircuitPreferredEP1OptVportread-writecurrentIf the circuit spans one or two rings, this is the lambda number of the first preferred ring.
1.3.6.1.4.1.5812.6.8.1.44ColumncircuitPreferredEP2OptSlotread-writecurrentIf the circuit spans two rings, this is the slot number of the second preferred ring. Preferred rings allow a manual overide of the routed circuit path.
1.3.6.1.4.1.5812.6.8.1.45ColumncircuitPreferredEP2OptPortread-writecurrentIf the circuit spans two rings, this is the port number of the second preferred ring.
1.3.6.1.4.1.5812.6.8.1.46ColumncircuitPreferredEP2OptVportread-writecurrentIf the circuit spans two rings, this is the lambda number of the second preferred ring.
1.3.6.1.4.1.5812.6.8.1.47ColumncircuitUseAlternateRingread-writecurrentAllows operator to specify whether an alternate ring can be used if the preferred ring(s) fail. This requires the ability to load-balance back onto the preferr…
1.3.6.1.4.1.5812.6.8.1.48ColumncircuitInFramesread-onlycurrentNumber of frames received at the ingress point and passed on to the circuit.
1.3.6.1.4.1.5812.6.8.1.49ColumncircuitInDEFramesread-onlycurrentNumber of frames received at the ingress point and passed on to the circuit.
1.3.6.1.4.1.5812.6.8.1.50ColumncircuitInOctetsread-onlycurrentNumber of octets received at the ingress point and passed on to the circuit.
1.3.6.1.4.1.5812.6.8.1.51ColumncircuitInDEOctetsread-onlycurrentNumber of octets received at the ingress point and passed on to the circuit.
1.3.6.1.4.1.5812.6.8.1.52ColumncircuitInCLP0Cellsread-onlycurrentNumber of cells received at the ingress point and passed on to the circuit.
1.3.6.1.4.1.5812.6.8.1.53ColumncircuitInCLP1Cellsread-onlycurrentNumber of cells received at the ingress point and passed on to the circuit.
1.3.6.1.4.1.5812.6.8.1.54ColumncircuitInFramesDiscardread-onlycurrentNumber of frames received at the ingress point but are discarded due to the non-conformance of the contract, i.e., it exceeds the traffic contract (BE).
1.3.6.1.4.1.5812.6.8.1.55ColumncircuitInDEFramesDiscardread-onlycurrentNumber of frames received at the ingress point but are discarded due to the non-conformance of the contract, i.e., it exceeds the traffic contract (BE).
1.3.6.1.4.1.5812.6.8.1.56ColumncircuitInOctetsDiscardread-onlycurrentNumber of octets received at the ingress point but are discarded due to the non-conformance of the contract, i.e., it exceeds the traffic contract (BE).
1.3.6.1.4.1.5812.6.8.1.57ColumncircuitInDEOctetsDiscardread-onlycurrentNumber of octets received at the ingress point but are discarded due to the non-conformance of the contract, i.e., it exceeds the traffic contract (BE).
1.3.6.1.4.1.5812.6.8.1.58ColumncircuitInCLP0CellsDiscardread-onlycurrentNumber of octets received at the ingress point but are discarded due to the non-conformance of the contract, i.e., it exceeds the traffic contract (BE).
1.3.6.1.4.1.5812.6.8.1.59ColumncircuitInCLP1CellsDiscardread-onlycurrentNumber of octets received at the ingress point but are discarded due to the non-conformance of the contract, i.e., it exceeds the traffic contract (BE).
1.3.6.1.4.1.5812.6.8.1.60ColumncircuitInFramesTaggedread-onlycurrentNumber of tagged frames received. A tagged frame represents non-conforming frames to the contract (when CIR < frame contract < BE). In these frames, the DE (Di…
1.3.6.1.4.1.5812.6.8.1.61ColumncircuitInOctetsTaggedread-onlycurrentNumber of tagged octets received. A tagged octet represents non-conforming octet to the contract (when CIR < octet contract < BE).In these octets, the DE (Disc…
1.3.6.1.4.1.5812.6.8.1.62ColumncircuitInCLP0CellsTaggedread-onlycurrentNumber of tagged octets received. A tagged octet represents non-conforming octet to the contract (when CIR < octet contract < BE).In these octets, the DE (Disc…
1.3.6.1.4.1.5812.6.8.1.63ColumncircuitOutFramesread-onlycurrentNumber of frames sent out through the circuit.
1.3.6.1.4.1.5812.6.8.1.64ColumncircuitOutDEFramesread-onlycurrentNumber of frames sent out through the circuit.
1.3.6.1.4.1.5812.6.8.1.65ColumncircuitOutOctetsread-onlycurrentNumber of octets sent out through the circuit.
1.3.6.1.4.1.5812.6.8.1.66ColumncircuitOutDEOctetsread-onlycurrentNumber of octets sent out through the circuit.
1.3.6.1.4.1.5812.6.8.1.67ColumncircuitOutCLP0Cellsread-onlycurrentNumber of cells sent out through the circuit.
1.3.6.1.4.1.5812.6.8.1.68ColumncircuitOutCLP1Cellsread-onlycurrentNumber of cells sent out through the circuit.
1.3.6.1.4.1.5812.24NodecircuitInactiveIndicates that the circuit became inactive and specifies the reason for it becoming inactive
1.3.6.1.4.1.5812.25NodecircuitActiveIndicates that the circuit became active
1.3.6.1.4.1.5812.26NodecircuitLoadBalancingIndicates that the circuit underwent load balancing