CNT241-MIB
74 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.333.2.4.1 | Nodecnt2Sm | |||
| 1.3.6.1.4.1.333.2.4.1.1 | Nodecnt2SmHw | |||
| 1.3.6.1.4.1.333.2.4.1.1 | Nodecnt2smEmergencyMsg | An emergency level trap (0) signifies that an event has occured which has rendered the system unusable. All modules and interfaces will be affected. | ||
| 1.3.6.1.4.1.333.2.4.1.1.1 | Scalarcnt2SmHwTemperatureF | read-only | mandatory | The temperature in Farenheit of the node in the range (0..255). If/when the temperature transitions from below 113 degrees to above 113 degrees, a advisory tra… |
| 1.3.6.1.4.1.333.2.4.1.1.2 | Scalarcnt2SmHwTapeDriveState | read-only | mandatory | The state of the DAT tape drive. |
| 1.3.6.1.4.1.333.2.4.1.1.3 | Scalarcnt2SmHwCdRomDriveState | read-only | mandatory | The state of the CD drive. |
| 1.3.6.1.4.1.333.2.4.1.1.4 | Scalarcnt2SmHwTapeMounted | read-only | mandatory | Indicates whether the DAT tape drive contains a tape. |
| 1.3.6.1.4.1.333.2.4.1.1.5 | Scalarcnt2SmHwCdRomMounted | read-only | mandatory | Indicates whether the CD drive contains a CD. |
| 1.3.6.1.4.1.333.2.4.1.1.6 | Scalarcnt2SmHwServiceLed | read-only | mandatory | The state of the service LED. |
| 1.3.6.1.4.1.333.2.4.1.1.7 | Scalarcnt2SmHwIplSwitch | read-only | mandatory | The state of the IPL switch. |
| 1.3.6.1.4.1.333.2.4.1.1.8 | Tablecnt2SmHwAdapterTable | not-accessible | mandatory | List of adapters in the node. |
| 1.3.6.1.4.1.333.2.4.1.1.8.1 | Rowcnt2SmHwAdapterEntry | not-accessible | mandatory | A adapter entry. |
| 1.3.6.1.4.1.333.2.4.1.1.8.1.1 | Columncnt2SmHwAdapterIndex | read-only | mandatory | The relative index of this adapter entry within the node. |
| 1.3.6.1.4.1.333.2.4.1.1.8.1.2 | Columncnt2SmHwAdapterOperState | read-only | mandatory | The state of the adapter in this slot. |
| 1.3.6.1.4.1.333.2.4.1.1.8.1.3 | Columncnt2SmHwAdapterAdminState | read-write | mandatory | The state of the adapter in this slot. |
| 1.3.6.1.4.1.333.2.4.1.1.9 | Tablecnt2SmHwCardTable | not-accessible | mandatory | List of adapters in the node. |
| 1.3.6.1.4.1.333.2.4.1.1.9.1 | Rowcnt2SmHwCardEntry | not-accessible | mandatory | A adapter entry. |
| 1.3.6.1.4.1.333.2.4.1.1.9.1.1 | Columncnt2SmCardAdapterIndex | read-only | mandatory | The relative index of this adapter entry within the node. |
| 1.3.6.1.4.1.333.2.4.1.1.9.1.2 | Columncnt2SmHwCardIndex | read-only | mandatory | The relative index of this adapter entry within the node. |
| 1.3.6.1.4.1.333.2.4.1.1.9.1.3 | Columncnt2SmHwCardOperState | read-only | mandatory | The state of the adapter in this slot. |
| 1.3.6.1.4.1.333.2.4.1.1.9.1.4 | Columncnt2SmHwCardAdminState | read-only | mandatory | The state of the adapter in this slot. |
| 1.3.6.1.4.1.333.2.4.1.1.10 | Tablecnt2SmHwPowerSupplyTable | not-accessible | mandatory | List of power supplies in the node. |
| 1.3.6.1.4.1.333.2.4.1.1.10.1 | Rowcnt2SmHwPowerSupplyEntry | not-accessible | mandatory | A power supply entry. |
| 1.3.6.1.4.1.333.2.4.1.1.10.1.1 | Columncnt2SmHwPowerSupplyIndex | read-only | mandatory | The relative index of this power supply entry within the node. |
| 1.3.6.1.4.1.333.2.4.1.1.10.1.2 | Columncnt2SmHwPowerSupplyACState | read-only | mandatory | The AC state of this power supply. |
| 1.3.6.1.4.1.333.2.4.1.1.10.1.3 | Columncnt2SmHwPowerSupplyDCState | read-only | mandatory | The DC state of this power supply. |
| 1.3.6.1.4.1.333.2.4.1.1.11 | Tablecnt2SmHwFanTable | not-accessible | mandatory | List of power supplies in the node. |
| 1.3.6.1.4.1.333.2.4.1.1.11.1 | Rowcnt2SmHwFanEntry | not-accessible | mandatory | A fan entry. |
| 1.3.6.1.4.1.333.2.4.1.1.11.1.1 | Columncnt2SmHwFanIndex | read-only | mandatory | The relative index of this fan entry within the node. |
| 1.3.6.1.4.1.333.2.4.1.1.11.1.2 | Columncnt2SmHwFanState | read-only | mandatory | The state of this fan. |
| 1.3.6.1.4.1.333.2.4.1.2 | Nodecnt2SmSw | |||
| 1.3.6.1.4.1.333.2.4.1.2 | Nodecnt2smAlertMsg | An Alert level trap (1) signifies that an event has occured which requires that immediate action be taken. The module will be affected. | ||
| 1.3.6.1.4.1.333.2.4.1.2.1 | Scalarcnt2SmNumModules | read-only | mandatory | The number of software modules making up the set referred to as the Service Monitor. |
| 1.3.6.1.4.1.333.2.4.1.2.2 | Tablecnt2SmSwTable | not-accessible | mandatory | List of entries in the service monitor software module table. |
| 1.3.6.1.4.1.333.2.4.1.2.2.1 | Rowcnt2SmSwEntry | not-accessible | mandatory | A service monitor software module entry. |
| 1.3.6.1.4.1.333.2.4.1.2.2.1.1 | Columncnt2SmSwIndex | read-only | mandatory | The relative index of this software module entry within the service monitor. |
| 1.3.6.1.4.1.333.2.4.1.2.2.1.2 | Columncnt2SmSwName | read-only | mandatory | The name of the service monitor module. |
| 1.3.6.1.4.1.333.2.4.1.2.2.1.3 | Columncnt2SmSwFunction | read-only | mandatory | The primary function performed by this software module. |
| 1.3.6.1.4.1.333.2.4.1.2.2.1.4 | Columncnt2SmSwMajorVersion | read-only | mandatory | The major version number of this software module. |
| 1.3.6.1.4.1.333.2.4.1.2.2.1.5 | Columncnt2SmSwMinorVersion | read-only | mandatory | The minor version number of this software module. |
| 1.3.6.1.4.1.333.2.4.1.2.3 | Scalarcnt2SmSwSlot | read-only | mandatory | The slot number of the active Service Monitor. |
| 1.3.6.1.4.1.333.2.4.1.2.4 | Scalarcnt2SmSwAccess | read-only | mandatory | The access permissions of the active Service Monitor. |
| 1.3.6.1.4.1.333.2.4.1.3 | Nodecnt2SmMsg | |||
| 1.3.6.1.4.1.333.2.4.1.3 | Nodecnt2smCriticalMsg | A Critical level trap (1) signifies that an event has occured for which action should be taken. The module will be affected. | ||
| 1.3.6.1.4.1.333.2.4.1.3.1 | Scalarcnt2SmNumMsgs | read-only | deprecated | The number of messages in the system message file that have been entered by all modules within the node. |
| 1.3.6.1.4.1.333.2.4.1.3.2 | Tablecnt2SmMsgTable | not-accessible | deprecated | List of entries in the service monitor message file. This file contains any messages that has been entered by any software residing in the node. |
| 1.3.6.1.4.1.333.2.4.1.3.2.1 | Rowcnt2SmMsgEntry | not-accessible | deprecated | A message file entry. |
| 1.3.6.1.4.1.333.2.4.1.3.2.1.1 | Columncnt2SmMsgIndex | read-only | deprecated | The relative index of this message entry within the message file. |
| 1.3.6.1.4.1.333.2.4.1.3.2.1.2 | Columncnt2SmMsgSeverity | read-only | deprecated | The severity of this message. |
| 1.3.6.1.4.1.333.2.4.1.3.2.1.3 | Columncnt2SmMsgProcessName | read-only | deprecated | The name of the process that sent this message to the message server. |
| 1.3.6.1.4.1.333.2.4.1.3.2.1.4 | Columncnt2SmMsgNumber | read-only | deprecated | The number of this message. Each module numbers its message type as another way of describing it. This message can then be cross-referenced in the CNT system m… |
| 1.3.6.1.4.1.333.2.4.1.3.2.1.5 | Columncnt2SmMsgSlotNumber | read-only | deprecated | The slot number of the module that sent this message to the message server. |
| 1.3.6.1.4.1.333.2.4.1.3.2.1.6 | Columncnt2SmMsgDateTime | read-only | deprecated | The date and time that this message was sent to the message server. |
| 1.3.6.1.4.1.333.2.4.1.3.2.1.7 | Columncnt2SmMsgErrorNumber | read-only | deprecated | The number of the Error message which caused us to generate this error message. Each module numbers its message errors as another way of describing it. |
| 1.3.6.1.4.1.333.2.4.1.3.2.1.8 | Columncnt2SmMsgContent | read-only | deprecated | The textual detail of the message sent to the message server. |
| 1.3.6.1.4.1.333.2.4.1.4 | Nodecnt2SmMessage | |||
| 1.3.6.1.4.1.333.2.4.1.4 | Nodecnt2smErrorMsg | An Error level trap (3) signifies that an event has occured that has resulted in errors. The module will probably be affected. | ||
| 1.3.6.1.4.1.333.2.4.1.4.1 | Scalarcnt2SmMsgTableSize | read-write | mandatory | The number of messages that are available through SNMP access. This message table is limited to the most recent number messages specified by this object. |
| 1.3.6.1.4.1.333.2.4.1.4.2 | Tablecnt2SmMessageTable | not-accessible | mandatory | List of entries in the service monitor message file. This file contains any messages that has been entered by any software residing in the node. |
| 1.3.6.1.4.1.333.2.4.1.4.2.1 | Rowcnt2SmMessageEntry | not-accessible | mandatory | A message file entry. |
| 1.3.6.1.4.1.333.2.4.1.4.2.1.1 | Columncnt2SmMessageText | read-only | mandatory | The textual detail of the message sent to the message server. |
| 1.3.6.1.4.1.333.2.4.1.4.2.1.2 | Columncnt2SmMessageIndex | read-only | mandatory | The textual index of the message sent to the message server. |
| 1.3.6.1.4.1.333.2.4.1.4.3 | Scalarcnt2SmMsgToTrapFilter | read-write | mandatory | Messages in cnt2SmMessageTable can be sent as traps to selected destinations. However, the messages are filtered by severity before they are forwarded as traps… |
| 1.3.6.1.4.1.333.2.4.1.5 | Nodecnt2smWarningMsg | A Warning level trap (4) signifies that an event has occured that may affect the module. | ||
| 1.3.6.1.4.1.333.2.4.1.6 | Nodecnt2smNoticeMsg | A Notice level trap (1) signifies that an event has occured that is normal but that has significance. The module should be unaffected | ||
| 1.3.6.1.4.1.333.2.4.1.7 | Nodecnt2smInfoMsg | An Informaiton level trap (6) signifies that an event has occured that informational in severity and that the module will not be affected by this error. | ||
| 1.3.6.1.4.1.333.2.4.1.8 | Nodecnt2smDebugMsg | A Debug level trap (7) signifies that an event has occured at a debug level that is informational. The module will not be affected by this error. | ||
| 1.3.6.1.4.1.333.2.4.1.9 | Nodecnt2smEmergencyTrap | An emergency level trap signifies that an event has occured which has rendered the system unusable. All modules and interfaces will be affected. | ||
| 1.3.6.1.4.1.333.2.4.1.10 | Nodecnt2smAlertTrap | An Alert level trap signifies that an event has occured which requires that immediate action be taken. The module will be affected. | ||
| 1.3.6.1.4.1.333.2.4.1.11 | Nodecnt2smCriticalTrap | A Critical level trap signifies that an event has occured for which action should be taken. The module will be affected. | ||
| 1.3.6.1.4.1.333.2.4.1.12 | Nodecnt2smErrorTrap | An Error level trap signifies that an event has occured that has resulted in errors. The module will probably be affected. | ||
| 1.3.6.1.4.1.333.2.4.1.13 | Nodecnt2smWarningTrap | A Warning level trap signifies that an event has occured that may affect the module. | ||
| 1.3.6.1.4.1.333.2.4.1.14 | Nodecnt2smNoticeTrap | A Notice level trap signifies that an event has occured that is normal but that has significance. The module should be unaffected | ||
| 1.3.6.1.4.1.333.2.4.1.15 | Nodecnt2smInfoTrap | An Informaiton level trap signifies that an event has occured that informational in severity and that the module will not be affected by this error. |