DAMOCLES-MIB
62 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.21796 | Nodehwgroup | |||
| 1.3.6.1.4.1.21796.3 | NodecharonII | |||
| 1.3.6.1.4.1.21796.3.4 | Nodedamocles | |||
| 1.3.6.1.4.1.21796.3.4.1 | NodeinpChange | Input changed. | ||
| 1.3.6.1.4.1.21796.3.4.1 | TableinpTable | not-accessible | current | A list of binary input entries. |
| 1.3.6.1.4.1.21796.3.4.1.1 | RowinpEntry | not-accessible | current | An entry containing information applicable to a particular binary input. |
| 1.3.6.1.4.1.21796.3.4.1.1.1 | ColumninpIndex | not-accessible | current | The binary input index. |
| 1.3.6.1.4.1.21796.3.4.1.1.2 | ColumninpState | read-only | current | The binary input state. |
| 1.3.6.1.4.1.21796.3.4.1.1.3 | ColumninpName | read-write | current | The binary input name. |
| 1.3.6.1.4.1.21796.3.4.1.1.4 | ColumninpAlarmSetup | read-write | current | You can enable alarm for this binary input. Alarm can be inactive or active for ON/OFF state. |
| 1.3.6.1.4.1.21796.3.4.1.1.5 | ColumninpAlarmState | read-only | current | The binary input alarm state. |
| 1.3.6.1.4.1.21796.3.4.1.1.6 | ColumninpCounter | read-write | current | Number of pulses on this input. Entering edge is used to increment this counter. Only pulses longer than sampling interval are counted. |
| 1.3.6.1.4.1.21796.3.4.2 | TableoutTable | not-accessible | current | A list of binary output entries. |
| 1.3.6.1.4.1.21796.3.4.2 | NodesensStateChanged | Sensor n changed its state. | ||
| 1.3.6.1.4.1.21796.3.4.2.1 | RowoutEntry | not-accessible | current | An entry containing information applicable to a particular binary output. |
| 1.3.6.1.4.1.21796.3.4.2.1.1 | ColumnoutIndex | not-accessible | current | The binary output index. |
| 1.3.6.1.4.1.21796.3.4.2.1.2 | ColumnoutState | read-write | current | The binary output state. 0 off(open), 1 on(close), 2 off if any alarm, 3 on if any alarm |
| 1.3.6.1.4.1.21796.3.4.2.1.3 | ColumnoutName | read-write | current | The binary output name. |
| 1.3.6.1.4.1.21796.3.4.2.1.4 | ColumnoutType | read-only | current | The binary output type. 0 relay (off, on), 1 rts (-10,+10v), 2 dtr (0,10v) |
| 1.3.6.1.4.1.21796.3.4.3 | TablesensTable | not-accessible | current | A list of sensor table entries. The number of entries corresponds with number of detected sensors. |
| 1.3.6.1.4.1.21796.3.4.3 | NodetsTrapNewAlarm | This trap is sent each time an alarm is inserted into to the alarm table. It is sent on the insertion of all alarms except for powerFailure. | ||
| 1.3.6.1.4.1.21796.3.4.3.1 | RowsensEntry | not-accessible | current | An entry containing information applicable to a particular sensor. |
| 1.3.6.1.4.1.21796.3.4.3.1.1 | ColumnsensIndex | not-accessible | current | The sensor index. |
| 1.3.6.1.4.1.21796.3.4.3.1.2 | ColumnsensName | read-only | current | The sensor name. |
| 1.3.6.1.4.1.21796.3.4.3.1.4 | ColumnsensState | read-only | current | The sensor state. |
| 1.3.6.1.4.1.21796.3.4.3.1.5 | ColumnsensString | read-only | current | The string representation of sensor value. |
| 1.3.6.1.4.1.21796.3.4.3.1.6 | ColumnsensValue | read-only | current | The integer (decimal * 10) representation of sensor value. |
| 1.3.6.1.4.1.21796.3.4.3.1.7 | ColumnsensValueRaw | read-only | current | The original raw value of sensor (it differs for each sensor type, especially 1-Wire sensors have different precisions). |
| 1.3.6.1.4.1.21796.3.4.3.1.8 | ColumnsensID | read-only | current | The sensor ID. |
| 1.3.6.1.4.1.21796.3.4.3.1.9 | ColumnsensUnit | read-only | current | The sensor unit. |
| 1.3.6.1.4.1.21796.3.4.4 | NodetsTrapAlarmEnd | This trap is sent each time an alarm is removed from the alarm table. It is sent on the removal of all alarms. | ||
| 1.3.6.1.4.1.21796.3.4.50 | NodetsAlarm | |||
| 1.3.6.1.4.1.21796.3.4.50.1 | ScalartsAlarmsPresent | read-only | current | The present number of active alarm conditions. |
| 1.3.6.1.4.1.21796.3.4.50.2 | TabletsAlarmTable | not-accessible | current | A list of alarm table entries. The table contains zero, one, or many rows at any moment, depending upon the number of alarm conditions in effect. The table is … |
| 1.3.6.1.4.1.21796.3.4.50.2.1 | RowtsAlarmEntry | not-accessible | current | An entry containing information applicable to a particular alarm. |
| 1.3.6.1.4.1.21796.3.4.50.2.1.1 | ColumntsAlarmIdx | not-accessible | current | An index to alarm table. |
| 1.3.6.1.4.1.21796.3.4.50.2.1.2 | ColumntsAlarmId | read-only | current | A unique identifier for an alarm condition. This value must remain constant. |
| 1.3.6.1.4.1.21796.3.4.50.2.1.3 | ColumntsAlarmDescr | read-only | current | Description of the alarm condition. |
| 1.3.6.1.4.1.21796.3.4.50.2.1.4 | ColumntsAlarmSensName | read-only | current | Name of sensor with alarm condition. |
| 1.3.6.1.4.1.21796.3.4.50.2.1.5 | ColumntsAlarmTime | read-only | current | The value of sysUpTime when the alarm condition was detected. If the alarm condition was detected at the time of agent startup and presumably existed before ag… |
| 1.3.6.1.4.1.21796.3.4.99 | Nodesetup | |||
| 1.3.6.1.4.1.21796.3.4.99.1 | NodesensSetup | |||
| 1.3.6.1.4.1.21796.3.4.99.1.1 | ScalarunitType | read-write | current | Units for displayed values. All setup values are fixed in Celsius |
| 1.3.6.1.4.1.21796.3.4.99.1.2 | TablesensSetupTable | not-accessible | current | A list of sensor table setup entries. The number of entries corresponds with number of detected sensors. |
| 1.3.6.1.4.1.21796.3.4.99.1.2.1 | RowsensSetupEntry | not-accessible | current | An entry containing setup information for a particular sensor. |
| 1.3.6.1.4.1.21796.3.4.99.1.2.1.1 | ColumnsensSetupIndex | not-accessible | current | The sensor setup table index. |
| 1.3.6.1.4.1.21796.3.4.99.1.2.1.2 | ColumnsensSetupName | read-write | current | The sensor name. |
| 1.3.6.1.4.1.21796.3.4.99.1.2.1.5 | ColumnsensFlags | read-write | current | The behaviour of sensor - 0x01: range or level detection - 0x02: enable trap sending - 0x08: sensor enabled - 0x10: enable SMS sending - 0x20: enable email sen… |
| 1.3.6.1.4.1.21796.3.4.99.1.2.1.6 | ColumnsensLimitMin | read-write | current | The sensor low limit. |
| 1.3.6.1.4.1.21796.3.4.99.1.2.1.7 | ColumnsensLimitMax | read-write | current | The sensor high limit. |
| 1.3.6.1.4.1.21796.3.4.99.1.2.1.8 | ColumnsensHysteresis | read-write | current | The sensor hysteresis. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| InputAlarmSetup | INTEGER { inactive (0), activeOff (1), activeOn (2) } | ||
| InputAlarmState | INTEGER { normal (1), alarm (2) } | ||
| NonNegativeInteger | INTEGER (0..2147483647) | ||
| OnOff | INTEGER { off (1), on (2) } | ||
| OutputType | INTEGER { onOff (0), rts (1), dtr (2) } | ||
| PositiveInteger | INTEGER (1..2147483647) | ||
| SensorFlags | INTEGER | ||
| SensorID | INTEGER (0..65535) | ||
| SensorState | INTEGER { invalid (0), normal (1), alarmstate (2), alarm (3) } | ||
| SensorValue | INTEGER | ||
| UnitType | INTEGER { celsius (0), fahrenheit (1), kelvin (2), percent(3), volt (4), miliamper (5), nounit (6), pulse (7), switch (8) } |