MIB Viewer

DDS-MIB

39 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.498.8Nodedsu
1.3.6.1.4.1.498.8.1Nodedds
1.3.6.1.4.1.498.8.1.1ScalarddsMIBversionread-onlymandatoryIdentifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y'identifies the minor revision number,…
1.3.6.1.4.1.498.8.1.2TableddsLineCfgTablenot-accessiblemandatoryThe GDC DDS Line Configuration table. Information in the entries of this table defines the configuration of DDS Line.
1.3.6.1.4.1.498.8.1.2.1RowddsLineCfgEntrynot-accessiblemandatoryThe GDC DDS Line Configuration Table Entry. The information in this entry defines the configuration for the Line of the associated DDS equipment.
1.3.6.1.4.1.498.8.1.2.1.1ColumnddsLineCfgIndexread-onlymandatoryThe index value that uniquely identifies the line interface to which this entry is applicable. This has the form of a SCinstance that defines the slot, line, d…
1.3.6.1.4.1.498.8.1.2.1.2ColumnddsLineTyperead-writemandatoryIdentifies the type of line. The value dds1(1) defines the line type as a conventional DDS. The value ddsSc(2) defines the line type as a DDS line with seconda…
1.3.6.1.4.1.498.8.1.2.1.3ColumnddsAutoDataRateDetectread-onlymandatoryThe value autoAsync(11) and autoSync(12) indicates that automatic data rate detection for async or sync communications is in progress. Once the data rate has b…
1.3.6.1.4.1.498.8.1.2.1.4ColumnddsDataRateread-writemandatoryThe DSU data rate option. This object is used to choose the operational data rate of the DSU. The two choices autoAsync(11) and autoSync(12) allow the DSU to a…
1.3.6.1.4.1.498.8.1.2.1.5ColumnddsTxClockSourceread-writemandatoryThe DSU transmit clock source option. This is the selection for the transmitter timing clock source. If connecting to a DDS circuit the value of receive(1) mus…
1.3.6.1.4.1.498.8.1.2.1.6ColumnddsZeroEncodingCfgread-writemandatoryThe DSU zero encoding option. This option, for point to point 56k DDS secondary channel circuits, allows the DTE equipment to transmit all '0' octets without v…
1.3.6.1.4.1.498.8.1.2.1.7ColumnddsDefaultConfigread-writemandatoryThe DSU default config option. When the value defaultCfg(2), is selected, the memory of the dataset will be erased, and the DSU configuration will be returned …
1.3.6.1.4.1.498.8.1.3TableddsDteCfgTablenot-accessiblemandatoryThe DDS DTE Configuration Table. Entries in this table pertain to the DTE interface, regardless of the operating mode (sync/async).
1.3.6.1.4.1.498.8.1.3.1RowddsDteCfgEntrynot-accessiblemandatoryThe GDC DTE Configuration Table Entry. The information in this entry defines the configuration for the associated DTE.
1.3.6.1.4.1.498.8.1.3.1.1ColumnddsDteCfgIndexread-onlymandatoryAn entry in the GDC DDS DTE Configuration Table.
1.3.6.1.4.1.498.8.1.3.1.2ColumnddsDteExtBuffClkread-writemandatoryThe DSU transmit buffer option. An optional elastic transmit buffer is inserted into the data path when a value of external(2) is selected. This elastic buffer…
1.3.6.1.4.1.498.8.1.3.1.3ColumnddsDteCfgTxCarrierread-writemandatoryThe Transmit Carrier option. This is feature allows the DTE equipment to directly control the transmitter carrier via signals on the RTS circuit. Typically, it…
1.3.6.1.4.1.498.8.1.3.1.4ColumnddsDteCfgRxCarrierread-writemandatoryThe Receive Carrier option. This option controls the operation of DCD. It is set to constant for multipoint remote and point to point applications. Switched(2)…
1.3.6.1.4.1.498.8.1.3.1.5ColumnddsDteCfgCtsDelayread-writemandatoryThe CTS delay option. Cts delay option of ctsOn(1) forces both RTS and CTS On regardless of the state of the attached business equipment. The CTS delay option …
1.3.6.1.4.1.498.8.1.3.1.6ColumnddsDteCfgLocalDSRread-writemandatoryThe DSR option. This option controls the operation of DSR. When forceOn(2) is selected, DSR is normally on, if set for followsDTR(1) then DSR is on only when D…
1.3.6.1.4.1.498.8.1.3.1.7ColumnddsDteCfgAnaloopDSRread-writemandatoryThe DSR in Line Loopback (Analoop) option. This option controls DSR during a Line Loopback test. When Line Loopback is active and the ddsDteCfgAnaloopDSR objec…
1.3.6.1.4.1.498.8.1.3.1.8ColumnddsDteCfgAasStatusread-writemandatoryThe Auto-anti Streaming option. A value of enable(1) means that the primary channel DSU transmitter is forced OFF (idle) if the business equipment's (DTE) RTS …
1.3.6.1.4.1.498.8.1.3.1.9ColumnddsDteCfgAasTimerread-writemandatoryThe Auto Anti-Streaming Timer monitor RTS. If RTS remains On for more then the selected time and ddsDteCfgAasStatus is selected for enable(1), the DSU forces O…
1.3.6.1.4.1.498.8.1.3.1.10ColumnddsDteCfgCircuitAssuranceread-writemandatoryThe Circuit Assurance option. The enable(2) configures the DSU to clamp CTS upon receiving the following Network codes: 1. IDLE(no DCD) 2. Out of Service Code …
1.3.6.1.4.1.498.8.1.3.1.11ColumnddsDteCfgSystemStatusread-writemandatoryThe System Status option enable(2) configures the DSU to clamp DSR upon receiving the following Network codes: 1. Out of Service Code (OOS) 2. Abnormal Station…
1.3.6.1.4.1.498.8.1.3.1.12ColumnddsDteCfgTermaloopread-writemandatoryThe Loopback Termination Mode. The enable(1) object stops the DSU from looping the DDS network interface while a local loopback is in progress. When the value …
1.3.6.1.4.1.498.8.1.4TableddsDteAsyncCfgTablenot-accessiblemandatoryThe Asynchronous Configuration table. Information in the entries of this table define the configuration of the DTE interface associated with the DDS device. Th…
1.3.6.1.4.1.498.8.1.4.1RowddsDteAsyncCfgEntrynot-accessiblemandatoryThe Asynchronous Configuration Table Entry. The information in this entry defines the configuration of the DTE interface.
1.3.6.1.4.1.498.8.1.4.1.1ColumnddsDteAsyncCfgIndexread-onlymandatoryThe index value which uniquely identifies the DTE interface to which this entry is applicable. Values for this object have the form of an SCinstance which defi…
1.3.6.1.4.1.498.8.1.4.1.2ColumnddsDteAsyncRateAdaptread-writemandatoryThe Async rate adaption object. The speed relationship between DDS circuit and DTE interface when configured for async communication is defined here. The none(…
1.3.6.1.4.1.498.8.1.4.1.3ColumnddsDteAsyncRxDelayread-writemandatoryWhen long(2) is selected, a 40 bit buffer in the receive data path is inserted. This buffer is used to filter out EOT. If ddsDteAsyncTxEOTcfg, and ddsDteAsyncR…
1.3.6.1.4.1.498.8.1.4.1.4ColumnddsDteAsyncTxEOTcfgread-writemandatoryThe configuration of the Transmit End-of-Text. The value enable(1) means that End-of-Text (EOT) will be transmitted. The value disable(2) inhibits EOT transmis…
1.3.6.1.4.1.498.8.1.4.1.5ColumnddsDteAsyncRxEOTcfgread-writemandatoryThe configuration of the Receive End-of-Text. The value enable(1) means that the unit will expect End-of-Text (EOT) and remove it from the data stream. The val…
1.3.6.1.4.1.498.8.1.4.1.6ColumnddsDteAsyncOverSpeedread-writemandatoryThis option is used to determine the amount of asynchronous overspeed the DSU tolerates. The overSpeed1 indicates that the DSU will accept incomming async data…
1.3.6.1.4.1.498.8.1.4.1.7ColumnddsDteAsyncCharacterSizeread-writemandatoryThis option selects the Asynchronous word size. The available settings are: 1) 8 bits/character. 2) 9 bits/character. 3) 10 bits/character. 4) 11 bits/characte…
1.3.6.1.4.1.498.8.1.6TableddsDteStatusTablenot-accessiblemandatoryThe DDS DTE Configuration Table. This entry pertains to the DTE interface.
1.3.6.1.4.1.498.8.1.6.1RowddsDteStatusEntrynot-accessiblemandatoryThe GDC DTE Configuration Table Entry. This entry defines the configuration for the associated DTE.
1.3.6.1.4.1.498.8.1.6.1.1ColumnddsDteStatusIndexread-onlymandatoryAn entry in the GDC DDS DTE Configuration Table.
1.3.6.1.4.1.498.8.1.6.1.2ColumnddsDteStatusread-onlymandatoryReturns a bitwise snapshot of the DTE signals. Octet 1 bit 7 - not used bit 6 - CTS (1:ON; 0:OFF) bit 5 - RTS (1:ON; 0:OFF) bit 4 - DTR (1:ON; 0:OFF) bit 3 - D…