DECHUB900-HUBMGR-MIB-V3-0
110 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises TimeTicks |
| RFC1213-MIB | DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.36 | Nodedec | |||
| 1.3.6.1.4.1.36.2 | Nodeema | |||
| 1.3.6.1.4.1.36.2.18 | NodedecMIBextension | |||
| 1.3.6.1.4.1.36.2.18.11 | NodedecHub900 | |||
| 1.3.6.1.4.1.36.2.18.11.1 | NodemgmtAgent | |||
| 1.3.6.1.4.1.36.2.18.11.1.2 | NodemgmtAgentVersion2 | |||
| 1.3.6.1.4.1.36.2.18.11.1.2.1 | NodemamPrivate | |||
| 1.3.6.1.4.1.36.2.18.11.1.2.1.1 | NodeeventLogger | |||
| 1.3.6.1.4.1.36.2.18.11.1.2.1.1 | NodehubRisingAlarm | The SNMP trap that is generated when an alarm entry crosses its rising threshold and generates an event that is configured for sending SNMP traps. The enterpri… | ||
| 1.3.6.1.4.1.36.2.18.11.1.2.1.1.1 | ScalareventLogTotalEvents | read-only | mandatory | The total number of events in the eventLogTable. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.1.2 | TableeventLogTable | not-accessible | mandatory | A list of eventLogEntry. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.1.2.1 | RoweventLogEntry | not-accessible | mandatory | A list of information describing 'interesting events' which have occurred in the hub or stack. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.1.2.1.1 | ColumneventLogIndex | read-only | mandatory | An index into the eventLogTable. This index begins at one and increments by one each time an event is logged. Older entries may be deleted to make room to newe… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.1.2.1.2 | ColumneventLogSlot | read-only | mandatory | The slot number of the module reporting the event. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.1.2.1.3 | ColumneventLogTimeStamp | read-only | mandatory | The time at which the event was logged. This is the Hub Manager's notion of sysUpTime, not the module's. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.1.2.1.4 | ColumneventLogDescription | read-only | mandatory | A textual description of the event. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2 | NodehubFallingAlarm | The SNMP trap that is generated when an alarm entry crosses its falling threshold and generates an event that is configured for sending SNMP traps. The enterpr… | ||
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2 | NodermonHub | |||
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1 | NodehubAlarm | |||
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1 | TablehubAlarmTable | not-accessible | mandatory | A list of alarm entries. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1 | RowhubAlarmEntry | not-accessible | mandatory | A list of parameters that set up periodic checking of alarm conditions. For example, an instance of the hubAlarmValue object might be named hubAlarmValue.4.8 f… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.1 | ColumnhubAlarmSlotNumber | read-only | mandatory | The number of the slot in which the module to be monitored occupies in the hub chassis or the module's position in a stack. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.2 | ColumnhubAlarmIndex | read-only | mandatory | An index that uniquely identifies an entry in the alarm table for a given slot. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.3 | ColumnhubAlarmInterval | read-write | mandatory | The interval, in seconds, over which the data is sampled and compared with the rising and falling thresholds. This object may not be modified if the associated… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.4 | ColumnhubAlarmVariable | read-write | mandatory | The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Counter, Gauge, or … |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.5 | ColumnhubAlarmSampleType | read-write | mandatory | The method of sampling the selected variable and calculating the value to be compared against the thresholds. If the value of this object is absoluteValue(1), … |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.6 | ColumnhubAlarmValue | read-only | mandatory | The value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value is the difference between the samples at … |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.7 | ColumnhubAlarmStartupAlarm | read-write | mandatory | The alarm that may be sent when this entry is first set to valid. If the first sample after this entry becomes valid is greater than or equal to the risingThre… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.8 | ColumnhubAlarmRisingThreshold | read-write | mandatory | A threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval w… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.9 | ColumnhubAlarmFallingThreshold | read-write | mandatory | A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was … |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.10 | ColumnhubAlarmRisingEventIndex | read-write | mandatory | The index of the eventEntry that is used when a rising threshold is crossed. The hubEventEntry identified by a particular value of this index is the same as id… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.11 | ColumnhubAlarmFallingEventIndex | read-write | mandatory | The index of the hubEventEntry that is used when a falling threshold is crossed. The hubEventEntry identified by a particular value of this index is the same a… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.12 | ColumnhubAlarmOwner | read-write | mandatory | The entity that configured this entry and is therefore using the resources assigned to it. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.13 | ColumnhubAlarmState | read-only | mandatory | The state of this alarm entry. Entries in the Alarm Table are marked as 'inactive' when the module to which they refer: - is removed or becomes 'asleep', - ret… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.14 | ColumnhubAlarmStatus | read-write | mandatory | The status of this alarm entry. (Refer to the RFC 1757 definition of 'EntryStatus.) |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2 | NodehubEvent | |||
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1 | TablehubEventTable | not-accessible | mandatory | A list of events to be generated. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1 | RowhubEventEntry | not-accessible | mandatory | A set of parameters that describe an event to be generated when certain conditions are met. As an example, an instance of the hubEventLastTimeSent object might… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.1 | ColumnhubEventIndex | read-only | mandatory | An index that uniquely identifies an entry in the event table. Each such entry defines one event that is to be generated when the appropriate conditions occur. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.2 | ColumnhubEventDescription | read-write | mandatory | A comment describing this hubEvent entry. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.3 | ColumnhubEventType | read-write | mandatory | The type of notification that the probe will make about this event. In the case of log, an entry is made in the log table for each event. In the case of snmp-t… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.4 | ColumnhubEventCommunity | read-write | mandatory | If an SNMP trap is to be sent, it will be sent to the SNMP community specified by this octet string. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.5 | ColumnhubEventLastTimeSent | read-only | mandatory | The value of sysUpTime at the time this event entry last generated an event. If this entry has not generated any events, this value is zero. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.6 | ColumnhubEventOwner | read-write | mandatory | The entity that configured this entry and is therefore using the resources assigned to it. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.7 | ColumnhubEventStatus | read-write | mandatory | The status of this event entry. If this object is not equal to valid(1), all associated log entries shall be deleted by the agent. (Refer to the RFC 1757 defin… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2 | TablehubLogTable | not-accessible | mandatory | A list of events that have been logged. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2.1 | RowhubLogEntry | not-accessible | mandatory | A set of data describing an event that has been logged. For example, an instance of the hubLogDescription object might be named hubLogDescription.6.47 |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2.1.1 | ColumnhubLogSlotNumber | read-only | mandatory | |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2.1.2 | ColumnhubLogEventIndex | read-only | mandatory | The event entry that generated this log entry. The log identified by a particular value of this index is associated with the same eventEntry as identified by t… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2.1.3 | ColumnhubLogIndex | read-only | mandatory | An index that uniquely identifies an entry in the log table amongst those generated by the same eventEntries. These indexes are assigned beginning with 1 and i… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2.1.4 | ColumnhubLogTime | read-only | mandatory | The value of sysUpTime when this log entry was created. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2.1.5 | ColumnhubLogDescription | read-only | mandatory | An implementation dependent description of the event that activated this log entry. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.3 | NodehubEtherCapabilities | |||
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1 | TablehubEtherCapabilitiesTable | not-accessible | mandatory | A list of Ethernet statistic capability entries. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1 | RowhubEtherCapabilitiesEntry | not-accessible | mandatory | An entry which describes the Ethernet monitoring capabilities or an interface or internal LAN. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1.1 | ColumnhubEtherCapabilitiesSlotNumber | read-only | mandatory | The number of the slot in which the device resides. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1.2 | ColumnhubEtherCapabilitiesIndex | read-only | mandatory | The number of the interface, port, or LAN described by this entry. Where possible, this index should match front bezel numbering. (And front-bezel numbering sh… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1.3 | ColumnhubEtherCapabilitiesLanType | read-only | mandatory | This enumeration describes interface, port, or LAN. The interface type is for any interface which can be described in the MIB-II interface table. Examples of i… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1.4 | ColumnhubEtherCapabilitiesLanSpeed | read-only | mandatory | The speed at which the Ethernet operates, in mega-bits per second. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1.5 | ColumnhubEtherCapabilitiesTrueCollisions | read-only | mandatory | The value of this object indicates if the etherStatsCollisions counter is accurately reported. The etherStatsCollisions counter is problematic in that it is de… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1.6 | ColumnhubEtherCapabilitiesState | read-write | mandatory | Setting hubEtherCapabilitiesState to 'active' has the side-effect of: o creating an entry in the hubEtherStatsTable, and o creating two entries in the hubHisto… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4 | NodehubStatistics | |||
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1 | TablehubEtherStatsTable | not-accessible | mandatory | A list of Ethernet statistics entries. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1 | RowhubEtherStatsEntry | not-accessible | mandatory | A collection of statistics kept for a particular Ethernet interface. As an example, an instance of the hubEtherStatsPkts object might be named hubEtherStatsPkt… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.1 | ColumnhubEtherStatsSlotNumber | read-only | mandatory | The number of the slot in which the device whose statistics are being gathered resides. This index corresponds to hubEtherCapabilitiesSlotNumber. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.2 | ColumnhubEtherStatsIndex | read-only | mandatory | An index into the hubEtherStatsTable. This index corresponds to hubEtherCapabilitiesIndex. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.3 | ColumnhubEtherStatsDropEvents | read-only | mandatory | The total number of events in which packets were dropped by the device due to lack of resources. Note that this number is not necessarily the number of packets… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.4 | ColumnhubEtherStatsOctets | read-only | mandatory | The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets). |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.5 | ColumnhubEtherStatsPkts | read-only | mandatory | The total number of packets (including bad packets, broadcast packets, and multicast packets) received. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.6 | ColumnhubEtherStatsBroadcastPkts | read-only | mandatory | The total number of good packets received that were directed to the broadcast address. Note that this does not include multicast packets. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.7 | ColumnhubEtherStatsMulticastPkts | read-only | mandatory | The total number of good packets received that were directed to a multicast address. Note that this number does not include packets directed to the broadcast a… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.8 | ColumnhubEtherStatsCRCAlignErrors | read-only | mandatory | The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but but had… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.9 | ColumnhubEtherStatsUndersizePkts | read-only | mandatory | The total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.10 | ColumnhubEtherStatsOversizePkts | read-only | mandatory | The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.11 | ColumnhubEtherStatsFragments | read-only | mandatory | The total number of packets received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.12 | ColumnhubEtherStatsJabbers | read-only | mandatory | The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Seq… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.13 | ColumnhubEtherStatsCollisions | read-only | mandatory | The best estimate of the total number of collisions on this Ethernet segment. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.14 | ColumnhubEtherStatsPkts64Octets | read-only | mandatory | The total number of packets (including bad packets) received that were 64 octets in length (excluding framing bits but including FCS octets). |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.15 | ColumnhubEtherStatsPkts65to127Octets | read-only | mandatory | The total number of packets (including bad packets) received that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS … |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.16 | ColumnhubEtherStatsPkts128to255Octets | read-only | mandatory | The total number of packets (including bad packets) received that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.17 | ColumnhubEtherStatsPkts256to511Octets | read-only | mandatory | The total number of packets (including bad packets) received that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.18 | ColumnhubEtherStatsPkts512to1023Octets | read-only | mandatory | The total number of packets (including bad packets) received that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FC… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.19 | ColumnhubEtherStatsPkts1024to1518Octets | read-only | mandatory | The total number of packets (including bad packets) received that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including F… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5 | NodehubHistory | |||
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.1 | ScalarhubHistoryControlFastPollInterval | read-write | mandatory | When hubEtherCapabilitiesState is set to active, two hubHistoryControlEntry are created; a fast poll entry with a default rate of 30 seconds, and a slot poll e… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.2 | ScalarhubHistoryControlSlowPollInterval | read-write | mandatory | When hubEtherCapabilitiesState is set to active, two hubHistoryControlEntry are created; a fast poll entry with a default rate of 30 seconds, and a slot poll e… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3 | TablehubHistoryControlTable | not-accessible | mandatory | A list of history control entries. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3.1 | RowhubHistoryControlEntry | not-accessible | mandatory | A list of parameters that set up a periodic sampling of statistics. As an example, an instance of the hubHistoryControlInterval object might be named hubHistor… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3.1.1 | ColumnhubHistoryControlSlotNumber | read-only | mandatory | The number of the slot in which the device's whose Ethernet history is being gathered resides. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3.1.2 | ColumnhubHistoryControlIndex | read-only | mandatory | |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3.1.3 | ColumnhubHistoryControlHistoryIndex | read-only | mandatory | An index which uniquely identifies instances of both this table and the hubHistoryTable. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3.1.4 | ColumnhubHistoryControlBuckets | read-only | mandatory | The number of sampling intervals over which data shall be saved in hubEtherHistoryTable. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3.1.5 | ColumnhubHistoryControlInterval | read-only | mandatory | The interval in seconds over which the data is sampled for each bucket in the part of the media-specific table associated with this hubHistoryControlEntry. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4 | TablehubEtherHistoryTable | not-accessible | mandatory | A list of Ethernet history entries. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1 | RowhubEtherHistoryEntry | not-accessible | mandatory | An historical sample of Ethernet statistics on a particular Ethernet interface. This sample is associated with the hubHistoryControlEntry which set up the para… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.1 | ColumnhubEtherHistoryIndex | read-only | mandatory | |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.2 | ColumnhubEtherHistorySampleIndex | read-only | mandatory | An index that uniquely identifies the particular sample this entry represents among all samples associated with the same hubHistoryControlEntry. This index sta… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.3 | ColumnhubEtherHistoryIntervalStart | read-only | mandatory | The value of sysUpTime at the start of the interval over which this sample was measured. If the probe keeps track of the time of day, it should start the first… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.4 | ColumnhubEtherHistoryDropEvents | read-only | mandatory | The total number of events in which packets were dropped by the probe due to lack of resources during this sampling interval. Note that this number is not nece… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.5 | ColumnhubEtherHistoryOctets | read-only | mandatory | The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets). |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.6 | ColumnhubEtherHistoryPkts | read-only | mandatory | The number of packets (including bad packets) received during this sampling interval. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.7 | ColumnhubEtherHistoryBroadcastPkts | read-only | mandatory | The number of good packets received during this sampling interval that were directed to the broadcast address. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.8 | ColumnhubEtherHistoryMulticastPkts | read-only | mandatory | The number of good packets received during this sampling interval that were directed to a multicast address. Note that this number does not include packets add… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.9 | ColumnhubEtherHistoryCRCAlignErrors | read-only | mandatory | The number of packets received during this sampling interval that had a length (excluding framing bits but including FCS octets) between 64 and 1518 octets, in… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.10 | ColumnhubEtherHistoryUndersizePkts | read-only | mandatory | The number of packets received during this sampling interval that were less than 64 octets long (excluding framing bits but including FCS octets) and were othe… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.11 | ColumnhubEtherHistoryOversizePkts | read-only | mandatory | The number of packets received during this sampling interval that were longer than 1518 octets (excluding framing bits but including FCS octets) but were other… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.12 | ColumnhubEtherHistoryFragments | read-only | mandatory | The total number of packets received during this sampling interval that were less than 64 octets in length (excluding framing bits but including FCS octets) ha… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.13 | ColumnhubEtherHistoryJabbers | read-only | mandatory | The number of packets received during this sampling interval that were longer than 1518 octets (excluding framing bits but including FCS octets), and had eithe… |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.14 | ColumnhubEtherHistoryCollisions | read-only | mandatory | The best estimate of the total number of collisions on this Ethernet segment during this sampling interval. |
| 1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.15 | ColumnhubEtherHistoryUtilization | read-only | mandatory | The best estimate of the mean physical layer network utilization on this interface during this sampling interval, in hundredths of a percent. |