MIB Viewer

DECHUB900-HUBMGR-MIB-V3-0

110 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.36Nodedec
1.3.6.1.4.1.36.2Nodeema
1.3.6.1.4.1.36.2.18NodedecMIBextension
1.3.6.1.4.1.36.2.18.11NodedecHub900
1.3.6.1.4.1.36.2.18.11.1NodemgmtAgent
1.3.6.1.4.1.36.2.18.11.1.2NodemgmtAgentVersion2
1.3.6.1.4.1.36.2.18.11.1.2.1NodemamPrivate
1.3.6.1.4.1.36.2.18.11.1.2.1.1NodeeventLogger
1.3.6.1.4.1.36.2.18.11.1.2.1.1NodehubRisingAlarmThe SNMP trap that is generated when an alarm entry crosses its rising threshold and generates an event that is configured for sending SNMP traps. The enterpri…
1.3.6.1.4.1.36.2.18.11.1.2.1.1.1ScalareventLogTotalEventsread-onlymandatoryThe total number of events in the eventLogTable.
1.3.6.1.4.1.36.2.18.11.1.2.1.1.2TableeventLogTablenot-accessiblemandatoryA list of eventLogEntry.
1.3.6.1.4.1.36.2.18.11.1.2.1.1.2.1RoweventLogEntrynot-accessiblemandatoryA list of information describing 'interesting events' which have occurred in the hub or stack.
1.3.6.1.4.1.36.2.18.11.1.2.1.1.2.1.1ColumneventLogIndexread-onlymandatoryAn index into the eventLogTable. This index begins at one and increments by one each time an event is logged. Older entries may be deleted to make room to newe…
1.3.6.1.4.1.36.2.18.11.1.2.1.1.2.1.2ColumneventLogSlotread-onlymandatoryThe slot number of the module reporting the event.
1.3.6.1.4.1.36.2.18.11.1.2.1.1.2.1.3ColumneventLogTimeStampread-onlymandatoryThe time at which the event was logged. This is the Hub Manager's notion of sysUpTime, not the module's.
1.3.6.1.4.1.36.2.18.11.1.2.1.1.2.1.4ColumneventLogDescriptionread-onlymandatoryA textual description of the event.
1.3.6.1.4.1.36.2.18.11.1.2.1.2NodehubFallingAlarmThe SNMP trap that is generated when an alarm entry crosses its falling threshold and generates an event that is configured for sending SNMP traps. The enterpr…
1.3.6.1.4.1.36.2.18.11.1.2.1.2NodermonHub
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1NodehubAlarm
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1TablehubAlarmTablenot-accessiblemandatoryA list of alarm entries.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1RowhubAlarmEntrynot-accessiblemandatoryA list of parameters that set up periodic checking of alarm conditions. For example, an instance of the hubAlarmValue object might be named hubAlarmValue.4.8 f…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.1ColumnhubAlarmSlotNumberread-onlymandatoryThe number of the slot in which the module to be monitored occupies in the hub chassis or the module's position in a stack.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.2ColumnhubAlarmIndexread-onlymandatoryAn index that uniquely identifies an entry in the alarm table for a given slot.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.3ColumnhubAlarmIntervalread-writemandatoryThe interval, in seconds, over which the data is sampled and compared with the rising and falling thresholds. This object may not be modified if the associated…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.4ColumnhubAlarmVariableread-writemandatoryThe object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Counter, Gauge, or …
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.5ColumnhubAlarmSampleTyperead-writemandatoryThe method of sampling the selected variable and calculating the value to be compared against the thresholds. If the value of this object is absoluteValue(1), …
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.6ColumnhubAlarmValueread-onlymandatoryThe value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value is the difference between the samples at …
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.7ColumnhubAlarmStartupAlarmread-writemandatoryThe alarm that may be sent when this entry is first set to valid. If the first sample after this entry becomes valid is greater than or equal to the risingThre…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.8ColumnhubAlarmRisingThresholdread-writemandatoryA threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval w…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.9ColumnhubAlarmFallingThresholdread-writemandatoryA threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was …
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.10ColumnhubAlarmRisingEventIndexread-writemandatoryThe index of the eventEntry that is used when a rising threshold is crossed. The hubEventEntry identified by a particular value of this index is the same as id…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.11ColumnhubAlarmFallingEventIndexread-writemandatoryThe index of the hubEventEntry that is used when a falling threshold is crossed. The hubEventEntry identified by a particular value of this index is the same a…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.12ColumnhubAlarmOwnerread-writemandatoryThe entity that configured this entry and is therefore using the resources assigned to it.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.13ColumnhubAlarmStateread-onlymandatoryThe state of this alarm entry. Entries in the Alarm Table are marked as 'inactive' when the module to which they refer: - is removed or becomes 'asleep', - ret…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.1.1.1.14ColumnhubAlarmStatusread-writemandatoryThe status of this alarm entry. (Refer to the RFC 1757 definition of 'EntryStatus.)
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2NodehubEvent
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1TablehubEventTablenot-accessiblemandatoryA list of events to be generated.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1RowhubEventEntrynot-accessiblemandatoryA set of parameters that describe an event to be generated when certain conditions are met. As an example, an instance of the hubEventLastTimeSent object might…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.1ColumnhubEventIndexread-onlymandatoryAn index that uniquely identifies an entry in the event table. Each such entry defines one event that is to be generated when the appropriate conditions occur.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.2ColumnhubEventDescriptionread-writemandatoryA comment describing this hubEvent entry.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.3ColumnhubEventTyperead-writemandatoryThe type of notification that the probe will make about this event. In the case of log, an entry is made in the log table for each event. In the case of snmp-t…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.4ColumnhubEventCommunityread-writemandatoryIf an SNMP trap is to be sent, it will be sent to the SNMP community specified by this octet string.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.5ColumnhubEventLastTimeSentread-onlymandatoryThe value of sysUpTime at the time this event entry last generated an event. If this entry has not generated any events, this value is zero.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.6ColumnhubEventOwnerread-writemandatoryThe entity that configured this entry and is therefore using the resources assigned to it.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.1.1.7ColumnhubEventStatusread-writemandatoryThe status of this event entry. If this object is not equal to valid(1), all associated log entries shall be deleted by the agent. (Refer to the RFC 1757 defin…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2TablehubLogTablenot-accessiblemandatoryA list of events that have been logged.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2.1RowhubLogEntrynot-accessiblemandatoryA set of data describing an event that has been logged. For example, an instance of the hubLogDescription object might be named hubLogDescription.6.47
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2.1.1ColumnhubLogSlotNumberread-onlymandatory
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2.1.2ColumnhubLogEventIndexread-onlymandatoryThe event entry that generated this log entry. The log identified by a particular value of this index is associated with the same eventEntry as identified by t…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2.1.3ColumnhubLogIndexread-onlymandatoryAn index that uniquely identifies an entry in the log table amongst those generated by the same eventEntries. These indexes are assigned beginning with 1 and i…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2.1.4ColumnhubLogTimeread-onlymandatoryThe value of sysUpTime when this log entry was created.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.2.2.1.5ColumnhubLogDescriptionread-onlymandatoryAn implementation dependent description of the event that activated this log entry.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.3NodehubEtherCapabilities
1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1TablehubEtherCapabilitiesTablenot-accessiblemandatoryA list of Ethernet statistic capability entries.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1RowhubEtherCapabilitiesEntrynot-accessiblemandatoryAn entry which describes the Ethernet monitoring capabilities or an interface or internal LAN.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1.1ColumnhubEtherCapabilitiesSlotNumberread-onlymandatoryThe number of the slot in which the device resides.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1.2ColumnhubEtherCapabilitiesIndexread-onlymandatoryThe number of the interface, port, or LAN described by this entry. Where possible, this index should match front bezel numbering. (And front-bezel numbering sh…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1.3ColumnhubEtherCapabilitiesLanTyperead-onlymandatoryThis enumeration describes interface, port, or LAN. The interface type is for any interface which can be described in the MIB-II interface table. Examples of i…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1.4ColumnhubEtherCapabilitiesLanSpeedread-onlymandatoryThe speed at which the Ethernet operates, in mega-bits per second.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1.5ColumnhubEtherCapabilitiesTrueCollisionsread-onlymandatoryThe value of this object indicates if the etherStatsCollisions counter is accurately reported. The etherStatsCollisions counter is problematic in that it is de…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.3.1.1.6ColumnhubEtherCapabilitiesStateread-writemandatorySetting hubEtherCapabilitiesState to 'active' has the side-effect of: o creating an entry in the hubEtherStatsTable, and o creating two entries in the hubHisto…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4NodehubStatistics
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1TablehubEtherStatsTablenot-accessiblemandatoryA list of Ethernet statistics entries.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1RowhubEtherStatsEntrynot-accessiblemandatoryA collection of statistics kept for a particular Ethernet interface. As an example, an instance of the hubEtherStatsPkts object might be named hubEtherStatsPkt…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.1ColumnhubEtherStatsSlotNumberread-onlymandatoryThe number of the slot in which the device whose statistics are being gathered resides. This index corresponds to hubEtherCapabilitiesSlotNumber.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.2ColumnhubEtherStatsIndexread-onlymandatoryAn index into the hubEtherStatsTable. This index corresponds to hubEtherCapabilitiesIndex.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.3ColumnhubEtherStatsDropEventsread-onlymandatoryThe total number of events in which packets were dropped by the device due to lack of resources. Note that this number is not necessarily the number of packets…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.4ColumnhubEtherStatsOctetsread-onlymandatoryThe total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets).
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.5ColumnhubEtherStatsPktsread-onlymandatoryThe total number of packets (including bad packets, broadcast packets, and multicast packets) received.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.6ColumnhubEtherStatsBroadcastPktsread-onlymandatoryThe total number of good packets received that were directed to the broadcast address. Note that this does not include multicast packets.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.7ColumnhubEtherStatsMulticastPktsread-onlymandatoryThe total number of good packets received that were directed to a multicast address. Note that this number does not include packets directed to the broadcast a…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.8ColumnhubEtherStatsCRCAlignErrorsread-onlymandatoryThe total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but but had…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.9ColumnhubEtherStatsUndersizePktsread-onlymandatoryThe total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.10ColumnhubEtherStatsOversizePktsread-onlymandatoryThe total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets) and were otherwise well formed.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.11ColumnhubEtherStatsFragmentsread-onlymandatoryThe total number of packets received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.12ColumnhubEtherStatsJabbersread-onlymandatoryThe total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad Frame Check Seq…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.13ColumnhubEtherStatsCollisionsread-onlymandatoryThe best estimate of the total number of collisions on this Ethernet segment.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.14ColumnhubEtherStatsPkts64Octetsread-onlymandatoryThe total number of packets (including bad packets) received that were 64 octets in length (excluding framing bits but including FCS octets).
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.15ColumnhubEtherStatsPkts65to127Octetsread-onlymandatoryThe total number of packets (including bad packets) received that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS …
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.16ColumnhubEtherStatsPkts128to255Octetsread-onlymandatoryThe total number of packets (including bad packets) received that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.17ColumnhubEtherStatsPkts256to511Octetsread-onlymandatoryThe total number of packets (including bad packets) received that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.18ColumnhubEtherStatsPkts512to1023Octetsread-onlymandatoryThe total number of packets (including bad packets) received that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FC…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.4.1.1.19ColumnhubEtherStatsPkts1024to1518Octetsread-onlymandatoryThe total number of packets (including bad packets) received that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including F…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5NodehubHistory
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.1ScalarhubHistoryControlFastPollIntervalread-writemandatoryWhen hubEtherCapabilitiesState is set to active, two hubHistoryControlEntry are created; a fast poll entry with a default rate of 30 seconds, and a slot poll e…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.2ScalarhubHistoryControlSlowPollIntervalread-writemandatoryWhen hubEtherCapabilitiesState is set to active, two hubHistoryControlEntry are created; a fast poll entry with a default rate of 30 seconds, and a slot poll e…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3TablehubHistoryControlTablenot-accessiblemandatoryA list of history control entries.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3.1RowhubHistoryControlEntrynot-accessiblemandatoryA list of parameters that set up a periodic sampling of statistics. As an example, an instance of the hubHistoryControlInterval object might be named hubHistor…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3.1.1ColumnhubHistoryControlSlotNumberread-onlymandatoryThe number of the slot in which the device's whose Ethernet history is being gathered resides.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3.1.2ColumnhubHistoryControlIndexread-onlymandatory
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3.1.3ColumnhubHistoryControlHistoryIndexread-onlymandatoryAn index which uniquely identifies instances of both this table and the hubHistoryTable.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3.1.4ColumnhubHistoryControlBucketsread-onlymandatoryThe number of sampling intervals over which data shall be saved in hubEtherHistoryTable.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.3.1.5ColumnhubHistoryControlIntervalread-onlymandatoryThe interval in seconds over which the data is sampled for each bucket in the part of the media-specific table associated with this hubHistoryControlEntry.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4TablehubEtherHistoryTablenot-accessiblemandatoryA list of Ethernet history entries.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1RowhubEtherHistoryEntrynot-accessiblemandatoryAn historical sample of Ethernet statistics on a particular Ethernet interface. This sample is associated with the hubHistoryControlEntry which set up the para…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.1ColumnhubEtherHistoryIndexread-onlymandatory
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.2ColumnhubEtherHistorySampleIndexread-onlymandatoryAn index that uniquely identifies the particular sample this entry represents among all samples associated with the same hubHistoryControlEntry. This index sta…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.3ColumnhubEtherHistoryIntervalStartread-onlymandatoryThe value of sysUpTime at the start of the interval over which this sample was measured. If the probe keeps track of the time of day, it should start the first…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.4ColumnhubEtherHistoryDropEventsread-onlymandatoryThe total number of events in which packets were dropped by the probe due to lack of resources during this sampling interval. Note that this number is not nece…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.5ColumnhubEtherHistoryOctetsread-onlymandatoryThe total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets).
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.6ColumnhubEtherHistoryPktsread-onlymandatoryThe number of packets (including bad packets) received during this sampling interval.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.7ColumnhubEtherHistoryBroadcastPktsread-onlymandatoryThe number of good packets received during this sampling interval that were directed to the broadcast address.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.8ColumnhubEtherHistoryMulticastPktsread-onlymandatoryThe number of good packets received during this sampling interval that were directed to a multicast address. Note that this number does not include packets add…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.9ColumnhubEtherHistoryCRCAlignErrorsread-onlymandatoryThe number of packets received during this sampling interval that had a length (excluding framing bits but including FCS octets) between 64 and 1518 octets, in…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.10ColumnhubEtherHistoryUndersizePktsread-onlymandatoryThe number of packets received during this sampling interval that were less than 64 octets long (excluding framing bits but including FCS octets) and were othe…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.11ColumnhubEtherHistoryOversizePktsread-onlymandatoryThe number of packets received during this sampling interval that were longer than 1518 octets (excluding framing bits but including FCS octets) but were other…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.12ColumnhubEtherHistoryFragmentsread-onlymandatoryThe total number of packets received during this sampling interval that were less than 64 octets in length (excluding framing bits but including FCS octets) ha…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.13ColumnhubEtherHistoryJabbersread-onlymandatoryThe number of packets received during this sampling interval that were longer than 1518 octets (excluding framing bits but including FCS octets), and had eithe…
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.14ColumnhubEtherHistoryCollisionsread-onlymandatoryThe best estimate of the total number of collisions on this Ethernet segment during this sampling interval.
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.15ColumnhubEtherHistoryUtilizationread-onlymandatoryThe best estimate of the mean physical layer network utilization on this interface during this sampling interval, in hundredths of a percent.