MIB Viewer

DELLRAC-MIB

54 objects
No module-level DESCRIPTION found.
Imported Objects
RFC-1215TRAP-TYPE
SNMPv2-SMIenterprises OBJECT-TYPE
OIDNameAccessStatusDescription
1.3.6.1.4.1.674Nodedell
1.3.6.1.4.1.674.10892Nodeserver3
1.3.6.1.4.1.674.10892.2NodedrsOutofBandGroup
1.3.6.1.4.1.674.10892.2.1NodedrsInformationGroup
1.3.6.1.4.1.674.10892.2.1.1NodedrsProductInfoGroup
1.3.6.1.4.1.674.10892.2.1.1.1ScalardrsProductNameread-onlymandatory0001.0001.0001 This attribute defines the product name of a remote access card.
1.3.6.1.4.1.674.10892.2.1.1.2ScalardrsProductShortNameread-onlymandatory0001.0001.0002 This attribute defines the short product name of a remote access card.
1.3.6.1.4.1.674.10892.2.1.1.3ScalardrsProductDescriptionread-onlymandatory0001.0001.0003 This attribute defines the product description of a remote access card.
1.3.6.1.4.1.674.10892.2.1.1.4ScalardrsProductManufacturerread-onlymandatory0001.0001.0004 This attribute defines the product manufacturer of a remote access card.
1.3.6.1.4.1.674.10892.2.1.1.5ScalardrsProductVersionread-onlymandatory0001.0001.0005 This attribute defines the product version of a remote access card.
1.3.6.1.4.1.674.10892.2.1.1.6ScalardrsChassisServiceTagread-onlymandatory0001.0001.0006 This attribute defines the service tag of the DELL chassis.
1.3.6.1.4.1.674.10892.2.1.1.7ScalardrsProductURLread-onlymandatory0001.0001.0007 This attribute defines the out-of-band UI URL of a remote access card.
1.3.6.1.4.1.674.10892.2.1.1.8ScalardrsProductChassisAssetTagread-onlymandatory0001.0001.0008 This attribute defines the Asset Tag of the DELL chassis.
1.3.6.1.4.1.674.10892.2.1.1.9ScalardrsProductChassisLocationread-onlymandatory0001.0001.0009 This attribute defines the location of the DELL chassis.
1.3.6.1.4.1.674.10892.2.1.1.10ScalardrsProductChassisNameread-onlymandatory0001.0001.0010 This attribute defines the name of the DELL chassis.
1.3.6.1.4.1.674.10892.2.1.1.11ScalardrsSystemServiceTagread-onlymandatory0001.0001.0011 This attribute defines the service tag of a DELL system.
1.3.6.1.4.1.674.10892.2.1.1.12ScalardrsProductSystemAssetTagread-onlymandatory0001.0001.0012 This attribute defines the asset tag of a DELL system.
1.3.6.1.4.1.674.10892.2.1.1.13ScalardrsProductSystemSlotread-onlymandatory0001.0001.0013 This attribute defines the slot number of a DELL system.
1.3.6.1.4.1.674.10892.2.1.1.14ScalardrsProductTyperead-onlymandatory0001.0001.0014 This attribute defines the type of a remote access card.
1.3.6.1.4.1.674.10892.2.1.2NodedrsFirmwareGroup
1.3.6.1.4.1.674.10892.2.1.2.1ScalardrsFirmwareVersionread-onlymandatory0001.0002.0001 This attribute defines the firmware version of a remote access card.
1.3.6.1.4.1.674.10892.2.2NodedrsStatusGroup
1.3.6.1.4.1.674.10892.2.2.1ScalardrsGlobalSystemStatusread-onlymandatory0002.0001 This attribute defines the overall DELL chassis status being monitored by the remote access card.
1.3.6.1.4.1.674.10892.2.1001NodealertDrscTestTrapEventThe RAC generated a test trap event in response to a user request.
1.3.6.1.4.1.674.10892.2.1002NodealertDrscAuthErrorThe RAC Authentication Failures during a time period have Exceeded a Threshold.
1.3.6.1.4.1.674.10892.2.1003NodealertDrscLostESMThe RAC cannot communicate with the baseboard management controller (ESM).
1.3.6.1.4.1.674.10892.2.1004NodealertDrscFoundESMThe RAC is communicating normally with the baseboard management controller (ESM).
1.3.6.1.4.1.674.10892.2.1005NodealertDrscPowerOffThe RAC has detected a System power state change to powered-off.
1.3.6.1.4.1.674.10892.2.1006NodealertDrscPowerOnThe RAC has detected a system power state change to powered-on.
1.3.6.1.4.1.674.10892.2.1007NodealertDrscWatchdogExpiredThe RAC has detected that the system watchdog has expired indicating a system hang.
1.3.6.1.4.1.674.10892.2.1008NodealertDrscBattLowThe RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes.
1.3.6.1.4.1.674.10892.2.1009NodealertDrscTempNormalThe RAC Temperature probe has retured to a normal value.
1.3.6.1.4.1.674.10892.2.1010NodealertDrscTempWarningThe RAC Temperature probe has detected a Warning value.
1.3.6.1.4.1.674.10892.2.1011NodealertDrscTempCriticalThe RAC Temperature probe has detected a failure (or critical) value.
1.3.6.1.4.1.674.10892.2.1012NodealertDrscVoltNormalThe RAC voltage has returned to a normal value.
1.3.6.1.4.1.674.10892.2.1013NodealertDrscVoltWarningThe RAC voltage probe has detected a warning value.
1.3.6.1.4.1.674.10892.2.1014NodealertDrscVoltCriticalThe RAC voltage probe has detected a failure (or critical) value.
1.3.6.1.4.1.674.10892.2.1015NodealertDrscSELWarningThe RAC has detected a new event in the System Event Log with Severity: Warning.
1.3.6.1.4.1.674.10892.2.1016NodealertDrscSELCriticalThe RAC has detected a new event in the System Event Log with Severity: Critical.
1.3.6.1.4.1.674.10892.2.1017NodealertDrscSEL80percentFullThe RAC has detected that the System Event Log is 80% full.
1.3.6.1.4.1.674.10892.2.1018NodealertDrscSEL90percentFullThe RAC has detected that the System Event Log is 90% full.
1.3.6.1.4.1.674.10892.2.1019NodealertDrscSEL100percentFullThe RAC has detected that the System Event Log is 100% full.
1.3.6.1.4.1.674.10892.2.1020NodealertDrscSELNormalThe RAC has detected a new event in the System Event Log with Severity: Normal.
1.3.6.1.4.1.674.10892.2.5000NodedrsAlertGroup
1.3.6.1.4.1.674.10892.2.5000.10NodedrsAlertVariables
1.3.6.1.4.1.674.10892.2.5000.10.1ScalardrsAlertSystemread-onlymandatory5000.0010.0001 Name of the system generating the alert.
1.3.6.1.4.1.674.10892.2.5000.10.2ScalardrsAlertTableIndexOIDread-onlymandatory5000.0010.0002 0.0
1.3.6.1.4.1.674.10892.2.5000.10.3ScalardrsAlertMessageread-onlymandatory5000.0010.0003 Message describing the alert.
1.3.6.1.4.1.674.10892.2.5000.10.4ScalardrsAlertCurrentStatusread-onlymandatory5000.0010.0004 Current status of object causing the alert.
1.3.6.1.4.1.674.10892.2.5000.10.5ScalardrsAlertPreviousStatusread-onlymandatory5000.0010.0005 Previous status of object causing the alert.
1.3.6.1.4.1.674.10892.2.5000.10.6ScalardrsAlertDataread-onlymandatory5000.0010.0006 Alert data.
Type Definitions
NameSyntaxStatusDescription
DellRacTypeINTEGER { other(1), unknown(2), dracIII(3), eRA(4), dRAC4(5), dRAC5(6), iDRAC(9) }
DellStatusINTEGER { other(1), unknown(2),
DisplayStringOCTET STRING