MIB Viewer

DL-NEW-DSX1-MIB

269 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.300Nodedigital-link
1.3.6.1.4.1.300.200Nodedl-new-t1
1.3.6.1.4.1.300.200.1NodedlcUnitHwConfig
1.3.6.1.4.1.300.200.1NodestartTestSent upon the initiation of a new test condition.
1.3.6.1.4.1.300.200.1.1ScalardlcUnitModelTyperead-onlymandatoryThe unit model type.
1.3.6.1.4.1.300.200.1.2ScalardlcUnitHwRevread-onlymandatoryThe ASCII code of the hardware revision number.
1.3.6.1.4.1.300.200.1.3ScalardlcUnitHwOptionsread-onlymandatoryA bit map, reported as the sum of all the values that correspond to installed options: realTimeClock ( 1) netPortT1 ( 2) netPortE1 ( 4) auxPortT1 ( 8) auxPortE…
1.3.6.1.4.1.300.200.1.4ScalardlcUnitSwRevread-onlymandatoryThe ASCII code of the software revision number.
1.3.6.1.4.1.300.200.1.5ScalardlcUnitDataPortsread-onlymandatoryThe number of data ports installed on the unit.
1.3.6.1.4.1.300.200.1.6ScalardlcUnitRamread-onlymandatoryThe amount of usable ram in the unit, in KBytes.
1.3.6.1.4.1.300.200.1.7ScalardlcUnitRomread-onlymandatoryThe amount of usable rom in the unit, in KBytes.
1.3.6.1.4.1.300.200.1.8ScalardlcUnitFlashread-onlymandatoryThe amount of FLASH ROM in the unit, in KBytes. If dlcUnitFlash is 0, the Downloadable Code option is not installed.
1.3.6.1.4.1.300.200.1.9ScalardlcUnitSlotNumread-onlymandatoryThe slot number the unit is in. If it's a stand alone unit, this object will return 0.
1.3.6.1.4.1.300.200.1.10ScalardlcUnitMibRevread-onlymandatoryThe ASCII code of the MIB revision number.
1.3.6.1.4.1.300.200.1.11ScalardlcUnitFeaturesread-onlymandatoryFeature configuration for Solo Select. The value returned is a bit mask of which feature key is on/capable when the corresponding bit is 1.
1.3.6.1.4.1.300.200.2NodedlcUnitConfig
1.3.6.1.4.1.300.200.2NodeendTestSent upon the termination of a test condition.
1.3.6.1.4.1.300.200.2.1ScalardlcUnitIdread-writemandatoryA name that uniquely and globally identifies the unit. The Unit ID must consist of (upper-case) letters 'A'..'Z' and digits '0'..'9'. The first character of th…
1.3.6.1.4.1.300.200.2.2ScalardlcUnitProtectModeread-writemandatoryWhen true, the unit configuration can not be changed from the front panel nor can tests be initiated or terminated from the front panel.
1.3.6.1.4.1.300.200.2.3ScalardlcUnitYellowEnableread-writemandatoryWhen false, yellow alarm conditions are ignored when received from a Dsx1 port, and the unit will never transmit a Yellow Alarm signal on a Dsx1 port. This app…
1.3.6.1.4.1.300.200.2.4ScalardlcUnitNetPassFdlread-writemandatoryIndicates which Dsx1 DTE port's FDL is connected to the `mainNet' FDL when this unit has no traffic of its own. Meaninigful values are `aux', `otherNet', and `…
1.3.6.1.4.1.300.200.2.5ScalardlcUnitMainClockSourceread-writemandatoryThis is the primary transmit timing source.
1.3.6.1.4.1.300.200.2.6ScalardlcUnitAltClockSourceread-writemandatoryThis is the alternate transmit timing source. It is used when the primary source is not available.
1.3.6.1.4.1.300.200.2.7ScalardlcUnitExtClockRateread-writemandatoryThe signal arriving at the BNC connector on the back of the unit, in units of KHz. Must be a multiple of 56 or 64 KHz (n*56 or n*64) or 1544. For T1 units, the…
1.3.6.1.4.1.300.200.2.8ScalardlcUnitFullBandwidthLoopCoderead-writemandatoryDetermines the loop codes we transmit for the Full Bandwidth Loop Up Remote and Loop Down Remote tests and the code we respond to when it's received on the NET…
1.3.6.1.4.1.300.200.2.9ScalardlcUnitFractionalLoopCoderead-writemandatoryDetermines the loop codes we transmit for the Fractional Loop Up Remote and Loop Down Remote tests and the code we respond to when it's received on fractional …
1.3.6.1.4.1.300.200.2.10ScalardlcUnitTestLengthread-writemandatoryDetermines the time interval after which tests are automatically terminated. Valid values are 0, 1, 15 and 60. 0 stands for unlimited, 1 for 1 minute, 15 for 1…
1.3.6.1.4.1.300.200.2.11ScalardlcUnitUserPattern1read-writemandatoryThis is a sequence of the characters '0' and '1' that represents the first of two user patterns. The first character represents the first bit in the sequence.
1.3.6.1.4.1.300.200.2.12ScalardlcUnitUserPattern2read-writemandatoryThis is a sequence of the characters '0' and '1' that represents the second of two user patterns. The first character represents the first bit in the sequence.
1.3.6.1.4.1.300.200.2.13ScalardlcUnitBlockAllAlarmsread-writemandatoryWhen dlcUnitBlockAllAlarms is TRUE, the unit will never send any traps.
1.3.6.1.4.1.300.200.2.14TabledlcUnitDsx1TrapEnableTablenot-accessiblemandatoryA list of traps that are related to a Dsx1 port.
1.3.6.1.4.1.300.200.2.14.1RowdlcDsx1TrapEnableEntrynot-accessiblemandatoryAn entry in the Dsx1 Trap Enable table.
1.3.6.1.4.1.300.200.2.14.1.1ColumndlcDsx1TrapPortIdread-onlymandatoryUniquely identifies this port. Valid values are `mainNet', `aux', `otherNet'.
1.3.6.1.4.1.300.200.2.14.1.2ColumndlcDsx1BpvThresholdTrapread-writemandatoryDefines Bipolar Violation Error Rate threshold in units of BPV errors per minute. When this threshold is exceeded, the unit will send a trap to the SNMP manage…
1.3.6.1.4.1.300.200.2.14.1.3ColumndlcDsx1OofThresholdTrapread-writemandatoryDefines the Out Of Frame Error Rate threshold in units of OOF errors per minute. The threshold is encoded the same as dlcDsx1BpvThresholdTrap. A value of 0 dis…
1.3.6.1.4.1.300.200.2.14.1.4ColumndlcDsx1CrcThresholdTrapread-writemandatoryDefines the CRC-6 Error Rate threshold in units of CRC errors per minute. The threshold is encoded the same as dlcDsx1BpvThresholdTrap. A value of 0 disables t…
1.3.6.1.4.1.300.200.2.14.1.5ColumndlcDsx1LossOfSignalTrapEnableread-writemandatoryEnables or disables a trap upon loss of network signal (LOS) on a Dsx1 port.
1.3.6.1.4.1.300.200.2.14.1.6ColumndlcDsx1LossOfSyncTrapEnableread-writemandatoryEnables or disables a trap upon loss of network framing (LOF) on a Dsx1 port.
1.3.6.1.4.1.300.200.2.14.1.7ColumndlcDsx1ReceiveAIStrapEnableread-writemandatoryEnables or disables a trap upon detection of AIS (Blue Alarm Signal) on a Dsx1 port.
1.3.6.1.4.1.300.200.2.14.1.8ColumndlcDsx1ReceiveYellowAlarmTrapEnableread-writemandatoryEnables or disables a trap upon detection of Yellow Alarm Signal on a Dsx1 port.
1.3.6.1.4.1.300.200.2.14.1.9ColumndlcDsx1ReceiveRemoteAlarmTrapEnableread-writemandatoryEnables or disables a trap upon detection of Remote Alarm Indicator on an E1 Dsx1 port. For T1 units, this object's value will always be read as 0 and set oper…
1.3.6.1.4.1.300.200.2.14.1.10ColumndlcDsx1PSfailureTrapEnableread-writemandatoryEnables or disables a trap upon a power supply failure. This object doesn't really belong in the dlcDsx1TrapEnableTable. It is specific to units that are insta…
1.3.6.1.4.1.300.200.2.14.1.11ColumndlcDsx1CntlCrdMissingTrapEnableread-writemandatoryEnables or disables a trap upon detection of a missing controller card. This object doesn't really belong in the dlcDsx1TrapEnableTable. It is specific to unit…
1.3.6.1.4.1.300.200.2.14.1.12ColumndlcDsx1FdlLinkTrapEnableread-writemandatoryEnables or disables a trap upon detection of the remote unit is not responding to DLC FDL messages.
1.3.6.1.4.1.300.200.2.14.1.13ColumndlcDsx1IbCrcThresholdTrapread-writemandatoryDefines the In-Band CRC Error Rate threshold in units of CRC errors per minute. The threshold is encoded the same as dlcDsx1BpvThresholdTrap. A value of 0 disa…
1.3.6.1.4.1.300.200.2.14.1.14ColumndlcDsx1InbandLinkTrapEnableread-writemandatoryEnables or disables a trap upon detection of the inband link.
1.3.6.1.4.1.300.200.2.15TabledlcUnitDataDteLossTrapEnableTablenot-accessiblemandatoryEnables or disables a trap upon the loss of signal on a Data DTE port.
1.3.6.1.4.1.300.200.2.15.1RowdlcDataDteLossTrapEnableEntrynot-accessiblemandatoryAn entry in the Data DTE Loss Trap Enable table.
1.3.6.1.4.1.300.200.2.15.1.1ColumndlcDataLossPortIdread-onlymandatoryUniquely identifies this port. Valid values are `data1' through `data32'.
1.3.6.1.4.1.300.200.2.15.1.2ColumndlcDataLossEnableread-writemandatorySays whether to enable this trap.
1.3.6.1.4.1.300.200.2.16ScalardlcUnitExternalAlarmInputTrapEnableread-writemandatoryEnables or disables a trap upon detection of an alarm condition on the External Alarm Input.
1.3.6.1.4.1.300.200.2.17ScalardlcUnitExternalAlarmInputContactsread-writemandatoryWhen set to normallyOpen, an alarm is declared when the contacts close ... and vice-versa.
1.3.6.1.4.1.300.200.2.18ScalardlcUnitExternalAlarmInputMessageread-writemandatoryA character string that describes what's going on when an alarm on the External Alarm Input is detected.
1.3.6.1.4.1.300.200.2.19ScalardlcUnitExternalAlarmOutputContactsread-writemandatoryWhen set to normallyOpen, the contacts close when any enabled alarm occurs and vice-versa. Pushing any button on the units Front Panel will cause the alarm con…
1.3.6.1.4.1.300.200.2.20ScalardlcUnitExternalAlarmOutputTrapEnableread-writemandatoryEnables or disables the external alarm output contacts.
1.3.6.1.4.1.300.200.2.21TabledlcUnitDsx1ConfigTablenot-accessiblemandatoryA table of configuration items for a Dsx1 port.
1.3.6.1.4.1.300.200.2.21.1RowdlcDsx1ConfigEntrynot-accessiblemandatoryAn entry in the Dsx1 configuration table.
1.3.6.1.4.1.300.200.2.21.1.1ColumndlcDsx1ConfigPortIdread-onlymandatoryUniquely identifies this port. Valid values are `mainNet', `aux', `otherNet'.
1.3.6.1.4.1.300.200.2.21.1.2ColumndlcDsx1Framingread-writemandatoryDsx1 framing type: T1 E1 Unstructured is E1 only, when in this mode, the E1 line acts like a 2048 Bps pipe with no framing information.
1.3.6.1.4.1.300.200.2.21.1.3ColumndlcDsx1LineCoderead-writemandatoryDsx1 line code type, AMI or B8ZS. E1 lines are always HDB3.
1.3.6.1.4.1.300.200.2.21.1.4ColumndlcDsx1LineMatchingread-writemandatoryDsx1 line build out or equalization: For a T1 NET port, LBO is 0, -7.5 or -15dB. For a T1 AUX port, EQ is 0..533 feet. For any E1 port, impedance is 75 or 120 …
1.3.6.1.4.1.300.200.2.21.1.5ColumndlcDsx1DacsModeread-writemandatoryTrue if DACS mode is in effect for this port.
1.3.6.1.4.1.300.200.2.21.1.6ColumndlcDsx1UseDlcFdlProtocolread-writemandatoryTrue when DLC FDL protocol is enabled over this port's FDL.
1.3.6.1.4.1.300.200.2.21.1.7ColumndlcDsx1UseAnsiProtocolread-writemandatoryTrue if ANSI Dsx1.403 is enabled over the FDL.
1.3.6.1.4.1.300.200.2.21.1.8ColumndlcDsx1Bit7Stuffingread-writemandatoryWhen true, bit 7 stuffing is turned on for a T1 Aux port to provide pulse density protection. Valid only on a T1 AUX port.
1.3.6.1.4.1.300.200.2.21.1.9ColumndlcDsx1InBandBitread-writemandatorySpecifies which bit in Timeslot 1 of an E1 link is used to pass message traffic. Not implemented for T1 ports.
1.3.6.1.4.1.300.200.2.22TabledlcUnitDataDteConfigTablenot-accessiblemandatoryThe data DTE configuration table.
1.3.6.1.4.1.300.200.2.22.1RowdlcDataDteConfigEntrynot-accessiblemandatoryAn entry in the data DTE configuration table.
1.3.6.1.4.1.300.200.2.22.1.1ColumndlcDataConfigPortIdread-onlymandatoryUniquely identifies this port. Valid values are `data1' through `data32'.
1.3.6.1.4.1.300.200.2.22.1.2ColumndlcDataConfigEncodingread-writemandatoryData DTE encoding type.
1.3.6.1.4.1.300.200.2.22.1.3ColumndlcDataConfigLossread-writemandatoryThe criterion to declare a Loss of Data DTE.
1.3.6.1.4.1.300.200.2.22.1.4ColumndlcDataConfigModeread-writemandatoryIn dteMode the unit is the DTE and the external equipment the DCE.
1.3.6.1.4.1.300.200.2.22.1.5ColumndlcDataConfigFormatread-writemandatorySelects V.35 or RS449 format.
1.3.6.1.4.1.300.200.2.22.1.6ColumndlcDataConfigTransmitTimingread-writemandatorySelects the Data DTE tramsmit timing source. Can be SCTE, SCT or inverted SCT.
1.3.6.1.4.1.300.200.2.23TabledlcUnitMuxConfigTablenot-accessiblemandatoryThis is the timeslot map configuration.
1.3.6.1.4.1.300.200.2.23.1RowdlcMuxConfigEntrynot-accessiblemandatoryAn entry in the timeslot map.
1.3.6.1.4.1.300.200.2.23.1.1ColumndlcMuxConfigBusIdread-onlymandatoryIdentifies which muxBus this timeslot is on.
1.3.6.1.4.1.300.200.2.23.1.2ColumndlcMuxConfigSlotNumberread-onlymandatoryUniquely identifies this timeslot.
1.3.6.1.4.1.300.200.2.23.1.3ColumndlcMuxConfigPortIdread-writemandatorySays which DTE port receives data from the indicated muxBus during this timeslot.
1.3.6.1.4.1.300.200.2.24NodedlcUnitSnmpConfig
1.3.6.1.4.1.300.200.2.24.1ScalardlcSnmpUnitIpAddrread-writemandatorySpecifies the IP address that is assigned to this unit.
1.3.6.1.4.1.300.200.2.24.2ScalardlcSnmpUnitNetMaskread-writemandatorySpecifies the net mask that this unit uses.
1.3.6.1.4.1.300.200.2.24.3ScalardlcSnmpTrapAddr1read-writemandatorySpecifies the IP address of the management station to which this unit sends traps.
1.3.6.1.4.1.300.200.2.24.4ScalardlcSnmpTrapAddr2read-writemandatorySpecifies the IP address of the management station to which this unit sends traps.
1.3.6.1.4.1.300.200.2.24.5ScalardlcSnmpTrapAddr3read-writemandatorySpecifies the IP address of the management station to which this unit sends traps.
1.3.6.1.4.1.300.200.2.24.6ScalardlcSnmpTrapDlci1read-writemandatorySpecifies the first of three DLCI value to which this unit sends TRAP PDUs.
1.3.6.1.4.1.300.200.2.24.7ScalardlcSnmpTrapDlci2read-writemandatorySpecifies the second of three DLCI value to which this unit sends TRAP PDUs.
1.3.6.1.4.1.300.200.2.24.8ScalardlcSnmpTrapDlci3read-writemandatorySpecifies the third of three DLCI value to which this unit sends TRAP PDUs.
1.3.6.1.4.1.300.200.2.24.9ScalardlcSnmpTrapDirection1read-writemandatorySpecifies the first of three Port to which this unit sends TRAP PDUs.
1.3.6.1.4.1.300.200.2.24.10ScalardlcSnmpTrapDirection2read-writemandatorySpecifies the second of three Port to which this unit sends TRAP PDUs.
1.3.6.1.4.1.300.200.2.24.11ScalardlcSnmpTrapDirection3read-writemandatorySpecifies the third of three Port to which this unit sends TRAP PDUs.
1.3.6.1.4.1.300.200.2.24.12ScalardlcSnmpTrapDirectionread-writemandatorySpecifies where this unit sends TRAP PDUs.
1.3.6.1.4.1.300.200.2.24.13NodedlcSnmpEthernetConfiguration
1.3.6.1.4.1.300.200.2.24.13.1ScalardlcEthernetIpAddrread-writemandatorySpecifies the IP address of Ethernet port.
1.3.6.1.4.1.300.200.2.24.13.2ScalardlcEthernetIpMaskread-writemandatorySpecifies the subnet mask of Ethernet port.
1.3.6.1.4.1.300.200.2.24.13.3ScalardlcEthernetGatewayAddrread-writemandatorySpecifies the gateway address of Ethernet port.
1.3.6.1.4.1.300.200.2.24.13.4ScalardlcEthernetMacAddrread-onlymandatoryThe MAC address of the Ethernet port.
1.3.6.1.4.1.300.200.2.25NodedlcUnitConfigTime
1.3.6.1.4.1.300.200.2.25.1ScalardlcUnitTimeYearread-writemandatoryThe unit's notion of the current year.
1.3.6.1.4.1.300.200.2.25.2ScalardlcUnitTimeMonthread-writemandatoryThe unit's notion of the current month.
1.3.6.1.4.1.300.200.2.25.3ScalardlcUnitTimeDayread-writemandatoryThe unit's notion of the current day.
1.3.6.1.4.1.300.200.2.25.4ScalardlcUnitTimeHourread-writemandatoryThe the unit's notion of the current hour.
1.3.6.1.4.1.300.200.2.25.5ScalardlcUnitTimeMinuteread-writemandatoryThe the unit's notion of the current minute.
1.3.6.1.4.1.300.200.2.25.6ScalardlcUnitTimeSecondread-writemandatoryThe the unit's notion of the current second.
1.3.6.1.4.1.300.200.2.26ScalardlcUnitSerialNumread-onlymandatoryAn ID that uniquely and globally identifies the unit. A Serial Number must consist of printable ASCII characters 0x20 ..0x7E.
1.3.6.1.4.1.300.200.2.27NodedlcUnitModemConfig
1.3.6.1.4.1.300.200.2.27.1ScalardlcModemPhoneNum1read-writemandatoryThe first phone number to dial when the unit needs to set up a modem connection.
1.3.6.1.4.1.300.200.2.27.2ScalardlcModemPhoneNum2read-writemandatoryThe second phone number to try if the phone number failed in setting up a modem connection.
1.3.6.1.4.1.300.200.2.27.3ScalardlcModemInitString1read-writemandatoryIn setting up a modem connection, the first group of commands used to initialize the modem.
1.3.6.1.4.1.300.200.2.27.4ScalardlcModemInitString2read-writemandatoryIn setting up a modem connection, the second group of commands used to initialize the modem. There is a delay between sending the first and second groups of in…
1.3.6.1.4.1.300.200.2.28ScalardlcUnitInbandModeread-onlymandatoryThe type of traffic expected on the link for inband management and IPM.
1.3.6.1.4.1.300.200.2.29ScalardlcUnitDialOutTimeIntervalread-writemandatoryA time interval for the dialout. The value should be between 0 and 255.
1.3.6.1.4.1.300.200.2.30ScalardlcAlarmSignalread-writemandatoryFramed/unframed aux alarm signal option
1.3.6.1.4.1.300.200.2.31ScalardlcUnitIdleCoderead-writemandatoryIdle Code that is send on unassigned time slots
1.3.6.1.4.1.300.200.2.32ScalardlcRemoteCommunicationsModeread-writemandatoryFramed/unframed aux alarm signal option
1.3.6.1.4.1.300.200.2.33NodedlcUnitConfigLinkTest
1.3.6.1.4.1.300.200.2.33.1ScalardlcLinkTestStateread-writemandatorySpecifies the status configuration of link based test. Only setable to values disabled(1) and enabled(2) to end and start the test respectively. Values running…
1.3.6.1.4.1.300.200.2.33.2ScalardlcLinkTestAddressread-writemandatorySpecifies the address for the next link based test to run.
1.3.6.1.4.1.300.200.2.33.3ScalardlcLinkTestDlciread-writemandatorySpecifies the frame relay DLCI for the next link based test to run. This value is used when the unit is in frameRelay InbandMode only and if the next link base…
1.3.6.1.4.1.300.200.2.33.4ScalardlcLinkTestPortread-writemandatorySpecifies which port to run the next link based test.
1.3.6.1.4.1.300.200.2.33.5ScalardlcLinkTestLengthread-writemandatorySpecifies the time length of the next test to run in minutes.
1.3.6.1.4.1.300.200.2.33.6ScalardlcLinkTestIntervalread-writemandatorySpecifies the repetition interval in seconds between packets for the next link based test.
1.3.6.1.4.1.300.200.2.33.7ScalardlcLinkTestPacketSizeread-writemandatorySpecifies the packet size for the next link based test.
1.3.6.1.4.1.300.200.2.33.8ScalardlcLinkTestPatternread-writemandatorySpecifies the test pattern for the next link based test.
1.3.6.1.4.1.300.200.2.34ScalardlcUnitInbandConfigread-onlymandatoryWhen true (== 2), inband management is enabled.
1.3.6.1.4.1.300.200.2.35ScalardlcUnitInbandTrafficTyperead-onlymandatoryThe type of traffic expected on the link for inband management and IPM.
1.3.6.1.4.1.300.200.2.36ScalardlcUnitPerformanceMonitoringread-writemandatoryWhen true (== 2), the integrated performance monitoring (IPM) is enabled
1.3.6.1.4.1.300.200.2.37ScalardlcUnitPvcAutoDiscoveryread-writemandatoryWhen true (== 2), automatic discovery of DLCIs is enabled
1.3.6.1.4.1.300.200.2.38NodedlcUnitDelayMonitorConfig
1.3.6.1.4.1.300.200.2.38.1TabledlcDelayMonitorConfigTablenot-accessiblemandatoryTable of Delay Monitor test configuration.
1.3.6.1.4.1.300.200.2.38.1.1RowdlcDelayMonitorConfigEntrynot-accessiblemandatoryAn entry in the network configuration table.
1.3.6.1.4.1.300.200.2.38.1.1.1ColumndlcDelayMonitorConfigIndexread-onlymandatoryUniquely identifies which delay monitor test in the configuration table.
1.3.6.1.4.1.300.200.2.38.1.1.2ColumndlcDelayMonitorStateread-writemandatorySpecifies the status configuration of this delay monitor. Only setable to values disabled(1) and enabled(2) to end and start the test respectively. Values runn…
1.3.6.1.4.1.300.200.2.38.1.1.3ColumndlcDelayMonitorTargetAddressread-writemandatorySpecifies the address for the next delay monitor to run.
1.3.6.1.4.1.300.200.2.38.1.1.4ColumndlcDelayMonitorDlciread-writemandatorySpecifies the frame relay DLCI for the next delay monitor to run. This value is used when the unit is in frameRelay InbandMode only and if the next delay monit…
1.3.6.1.4.1.300.200.2.38.1.1.5ColumndlcDelayMonitorPortread-writemandatorySpecifies which port to run the next delay monitor.
1.3.6.1.4.1.300.200.2.38.1.1.6ColumndlcDelayMonitorIntervalread-writemandatorySpecifies the repetition interval in seconds between packets for the next delay monitor to run.
1.3.6.1.4.1.300.200.2.38.1.1.7ColumndlcDelayMonitorPacketSizeread-writemandatorySpecifies the packet size for the next delay monitor.
1.3.6.1.4.1.300.200.2.38.1.1.8ColumndlcDelayMonitorPatternread-writemandatorySpecifies the test pattern for the next delay monitor.
1.3.6.1.4.1.300.200.2.39TabledlcDLCItablenot-accessiblemandatoryTable for current DLCI
1.3.6.1.4.1.300.200.2.39.1RowdlcDLCItableEntrynot-accessiblemandatoryAn entry for a DLCI
1.3.6.1.4.1.300.200.2.39.1.1ColumndlcDLCInumberread-onlymandatoryIdentifies DLCI number.
1.3.6.1.4.1.300.200.2.39.1.2ColumndlcDTECIRread-onlymandatoryThis DLCI's DTE Confirmed Information Rate (CIR)
1.3.6.1.4.1.300.200.2.39.1.3ColumndlcNETCIRread-onlymandatoryThis DLCI's NET Confirmed Information Rate (CIR)
1.3.6.1.4.1.300.200.2.39.1.4ColumndlcDLCIstatusread-writemandatoryThis object represents status of the entry. When read, it will return status 'active' or 'inactive' representing the status of the row. When written, this obje…
1.3.6.1.4.1.300.200.2.41NodedlcLMIConditioningGroup
1.3.6.1.4.1.300.200.2.41.1NodedlcLMIConfiguration
1.3.6.1.4.1.300.200.2.41.1.1ScalardlcLMIEnableread-writemandatoryThis object specifies whether to enable or disable LMI Conditioning.
1.3.6.1.4.1.300.200.2.41.1.2ScalardlcMaintenanceDLCIread-writemandatoryThis objects specifies the status of the LMI Spoofing.
1.3.6.1.4.1.300.200.2.41.1.3ScalardlcManagementDLCIread-writemandatoryThis objects specifies the number of management DLCI between 16 and 991 inclusive. Must not be the same as maintenance DLCI. Default is 989.
1.3.6.1.4.1.300.200.2.41.1.4ScalardlcManagementDLCIEnableread-writemandatoryThis object specifies whether to enable or disable Management DLCI.
1.3.6.1.4.1.300.200.2.41.1.5ScalardlcSpoofingProtocolTyperead-writemandatoryThis objects configures which LMI message type to 'spoof', in the event that spoofing is activated. The possible choices are FRF 1.0 (Frame Relay Forum's early…
1.3.6.1.4.1.300.200.2.41.1.6ScalardlcDTESpoofingEnableread-writemandatoryIf the value of this object is 'enabled', LMI spoofing to the DTE port is done automatically.
1.3.6.1.4.1.300.200.2.41.1.7ScalardlcNetSpoofingEnableread-writemandatoryIf the value of this object is 'enabled', LMI spoofing to the Network port is done automatically.
1.3.6.1.4.1.300.200.2.41.1.8ScalardlcLinkIntegrityVerificationPollingTimerread-writemandatoryThis object is the interval in seconds between Link Integrity Verification Messages. This is known as T391 in the standards. Possible values are 5 to 30 second…
1.3.6.1.4.1.300.200.2.41.1.9ScalardlcFullStatusPollingCounterread-writemandatoryThis value corresponds to N391 in the ITU and ANSI standards. It is the number of polling cycles of the type before the unit generates the full status request.…
1.3.6.1.4.1.300.200.2.41.1.10ScalardlcLMIErrorEventread-writemandatoryThis object configures the parameter which sets the number of errors that can occur on the LMI link in LMI Error Monitored Events before reporting an interface…
1.3.6.1.4.1.300.200.2.41.1.11ScalardlcLMIErrorMonitorEventread-writemandatoryThis object configures parameter which sets the number of events that are used with the LMI Error Event to define the error ratio that is used to report when t…
1.3.6.1.4.1.300.200.2.41.1.12ScalardlcLMIErrorFreeEventread-writemandatoryThis object configures the parameter which sets the number of error-free messages that must be received in LMI Error Free Monitored Events prior to declaring a…
1.3.6.1.4.1.300.200.2.41.1.13ScalardlcLMIErrorFreeMonitorEventread-writemandatoryThis object configures parameter which sets the number of events that are used with the LMI Error Free Event to define the error ratio that is used to report t…
1.3.6.1.4.1.300.200.2.41.1.14ScalardlcDTEResponseTimerread-writemandatoryThis object configures the parameter which sets the number of seconds between the sending of a status enquiry message and the receipt of a response. Applies to…
1.3.6.1.4.1.300.200.2.41.1.15ScalardlcLMIUnitLocationread-writemandatoryThis object configures where the unit is located so that LMI spoofing could be done properly. If 'cpe' is selected, it means the unit is located in Customer Pr…
1.3.6.1.4.1.300.200.2.41.2NodedlcLMIStatus
1.3.6.1.4.1.300.200.2.41.2.1ScalardlcSpoofingStatusread-onlymandatoryThis object configures automatic LMI spoofing to the router. 'True' means LMI spoofing will occur automatically, 'False' means it's disabled.
1.3.6.1.4.1.300.200.2.41.2.2ScalardlcDTEInterfaceLMIStatusread-onlymandatoryThis object indicates the LMI status of DTE interface.
1.3.6.1.4.1.300.200.2.41.2.3ScalardlcNetInterfaceLMIStatusread-onlymandatoryThis object indicates the LMI status of Net interface.
1.3.6.1.4.1.300.200.2.42ScalardlcInbandDtePortread-writemandatoryThis object configures which DTE port has inband management.
1.3.6.1.4.1.300.200.3NodedlcUnitStatus
1.3.6.1.4.1.300.200.3NodestartAlarmIndicates the beginning of a new alarm condition.
1.3.6.1.4.1.300.200.3.1ScalardlcUnitCurrentStatusread-onlymandatoryWhat's going on in this unit?
1.3.6.1.4.1.300.200.3.2ScalardlcUnitErrorFreeSecondsread-onlymandatoryRepresents the percent of error free seconds over the last 24 hours. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is e…
1.3.6.1.4.1.300.200.3.3ScalardlcUnitLastSelfTestResultread-onlymandatoryThe result of the last self test. unitLastSelfTest is a bitmap ... the sum of: 0 Selftest passed 1 ROM checksum failure 2 RAM test failure 4 EEPROM CRC failure…
1.3.6.1.4.1.300.200.3.4TabledlcUnitPortStatusTablenot-accessiblemandatoryA table of all port-related status
1.3.6.1.4.1.300.200.3.4.1RowdlcPortStatusEntrynot-accessiblemandatoryAn entry in the port status table.
1.3.6.1.4.1.300.200.3.4.1.1ColumndlcPortStatusIdread-onlymandatoryIdentifies which port (NET, AUX, Data DTE, or whatever) this status entry is describing.
1.3.6.1.4.1.300.200.3.4.1.2ColumndlcPortStatusread-onlymandatoryGives the actual status value for to this port.
1.3.6.1.4.1.300.200.3.4.1.3ColumndlcPortStatusNetRxBwUtilizationread-onlymandatoryRepresents the percent of net receive bandwidth utilization over the last 60 seconds. The number is multiplied by 10 and rounded to the nearest integer. For ex…
1.3.6.1.4.1.300.200.3.4.1.4ColumndlcPortStatusNetTxBwUtilizationread-onlymandatoryRepresents the percent of net receive bandwidth utilization over the last 60 seconds. The number is multiplied by 10 and rounded to the nearest integer. For ex…
1.3.6.1.4.1.300.200.3.5TabledlcUnitAlarmTablenot-accessiblemandatoryA table of all currently-raised alarms
1.3.6.1.4.1.300.200.3.5.1RowdlcAlarmEntrynot-accessiblemandatoryAn entry in the alarm table.
1.3.6.1.4.1.300.200.3.5.1.1ColumndlcAlarmPortread-onlymandatoryIdentifies which port (NET, AUX, Data DTE, or whatever) this alarm relates to.
1.3.6.1.4.1.300.200.3.5.1.2ColumndlcAlarmTyperead-onlymandatoryIdentifies an alarm that's currently outstanding against this port.
1.3.6.1.4.1.300.200.3.6ScalardlcUnitErrorSecondsRatioread-onlymandatoryRepresents the percent of error seconds over the last 24 hours. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encode…
1.3.6.1.4.1.300.200.3.7ScalardlcUnitSeverelyErroredSecondsRatioread-onlymandatoryRepresents the percent of severely errored seconds over the last 24 hours. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2…
1.3.6.1.4.1.300.200.3.8ScalardlcUnitBackgroundBlockErrorRatioread-onlymandatoryRepresents the percent of background block errors over the last 24 hours. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2%…
1.3.6.1.4.1.300.200.4NodedlcUnitUserArchive
1.3.6.1.4.1.300.200.4NodeendAlarmIndicates the end of an alarm condition.
1.3.6.1.4.1.300.200.4.1TabledlcUnitUserArchiveValidTablenot-accessiblemandatoryA table of all port-related status
1.3.6.1.4.1.300.200.4.1.1RowdlcUserArchiveValidEntrynot-accessiblemandatoryAn entry in the user archive valid-intervals table.
1.3.6.1.4.1.300.200.4.1.1.1ColumndlcValidPortIdread-onlymandatoryIdentifies which port (`net' or `otherNet') this entry is describing.
1.3.6.1.4.1.300.200.4.1.1.2ColumndlcValidIntervalsread-writemandatoryThe number of valid intervals in the user's error register database for this port. Writing a 0 to this variable will clear the entire archive for this port. Wr…
1.3.6.1.4.1.300.200.4.2TabledlcUnitUserLifetimeTablenot-accessiblemandatoryA table of the lifetime error counts, per-port.
1.3.6.1.4.1.300.200.4.2.1RowdlcUserLifetimeEntrynot-accessiblemandatoryAn entry in the user archive lifetime-totals table.
1.3.6.1.4.1.300.200.4.2.1.1ColumndlcLifetimePortIdread-onlymandatoryIdentifies which port (`net' or `otherNet') this entry relates to.
1.3.6.1.4.1.300.200.4.2.1.2ColumndlcLifetimeESread-writemandatoryAn ongoing count of Errored Seconds detected on this network port. Can be read and written (to zero).
1.3.6.1.4.1.300.200.4.2.1.3ColumndlcLifetimeUASread-writemandatoryAn ongoing count of Unavailable Seconds detected on this network port. Can be read and written (to zero).
1.3.6.1.4.1.300.200.4.2.1.4ColumndlcLifetimeCrcErrorsread-writemandatoryAn ongoing count of the CRC errors detected on this network port. Can be read and written (to zero).
1.3.6.1.4.1.300.200.4.2.1.5ColumndlcLifetimeBpvErrorsread-writemandatoryAn ongoing count of the Code Violation errors detected on this network port. Can be read and written (to zero).
1.3.6.1.4.1.300.200.4.2.1.6ColumndlcLifetimeOofErrorsread-writemandatoryFor an ESF T1 port, an ongoing count of Out-Of-Frame errors. For a D4 T1 port, an ongoing count of Framing Errors. Available only for the network port. Can be …
1.3.6.1.4.1.300.200.4.2.1.7ColumndlcLifetimeIbCrcErrorsread-writemandatoryAn ongoing count of the FCS errors detected on this network port.
1.3.6.1.4.1.300.200.4.3TabledlcUnitUserCurrentTablenot-accessiblemandatoryA table of all the current interval error counts, per-port.
1.3.6.1.4.1.300.200.4.3.1RowdlcUserCurrentEntrynot-accessiblemandatoryAn entry in the user archive current interval table.
1.3.6.1.4.1.300.200.4.3.1.1ColumndlcCurrentPortIdread-onlymandatoryIdentifies which port (`net' or `otherNet') this entry relates to.
1.3.6.1.4.1.300.200.4.3.1.2ColumndlcCurrentESread-onlymandatoryErrored seconds in the interval.
1.3.6.1.4.1.300.200.4.3.1.3ColumndlcCurrentUASread-onlymandatoryUnavailable seconds in the interval.
1.3.6.1.4.1.300.200.4.3.1.4ColumndlcCurrentCrcErrorsread-onlymandatoryCRC Errors in the interval.
1.3.6.1.4.1.300.200.4.3.1.5ColumndlcCurrentBpvErrorsread-onlymandatoryCode Violation Errors in the interval.
1.3.6.1.4.1.300.200.4.3.1.6ColumndlcCurrentOofErrorsread-onlymandatoryOOF or Framing Errors in the interval.
1.3.6.1.4.1.300.200.4.3.1.7ColumndlcCurrentTimeElapsedread-onlymandatoryThe number of seconds that have elapsed since the beginning of the current error-measurement period. Available only for the network port.
1.3.6.1.4.1.300.200.4.3.1.8ColumndlcCurrentIbCrcErrorsread-onlymandatoryFCS Errors in the interval.
1.3.6.1.4.1.300.200.4.4TabledlcUnitUserArchiveTablenot-accessiblemandatoryA table of all the archive intervals' error counts, per-port.
1.3.6.1.4.1.300.200.4.4.1RowdlcUserArchiveEntrynot-accessiblemandatoryAn entry in the user archive table.
1.3.6.1.4.1.300.200.4.4.1.1ColumndlcArchivePortIdread-onlymandatoryIdentifies which port (`net' or `otherNet') this entry relates to.
1.3.6.1.4.1.300.200.4.4.1.2ColumndlcArchiveIntervalread-onlymandatoryIdentifies which interval this secondaryArchiveEntry describes. 1 indicates the most-recent interval.
1.3.6.1.4.1.300.200.4.4.1.3ColumndlcArchiveESread-onlymandatoryErrored seconds in the interval.
1.3.6.1.4.1.300.200.4.4.1.4ColumndlcArchiveUASread-onlymandatoryUnavailable seconds in the interval.
1.3.6.1.4.1.300.200.4.4.1.5ColumndlcArchiveCrcErrorsread-onlymandatoryCRC Errors in the interval.
1.3.6.1.4.1.300.200.4.4.1.6ColumndlcArchiveBpvErrorsread-onlymandatoryCode Violation Errors in the interval.
1.3.6.1.4.1.300.200.4.4.1.7ColumndlcArchiveOofErrorsread-onlymandatoryOOF or Framing Errors in the interval.
1.3.6.1.4.1.300.200.4.4.1.8ColumndlcArchiveIbCrcErrorsread-onlymandatoryFCS Errors in the interval.
1.3.6.1.4.1.300.200.4.4.1.9ColumndlcArchiveNetRxBwUtilizationread-onlymandatoryNet Rx Bandwidth Utilization in the interval.
1.3.6.1.4.1.300.200.4.4.1.10ColumndlcArchiveNetRxPacketsread-onlymandatoryNet Rx Packets in the interval.
1.3.6.1.4.1.300.200.4.4.1.11ColumndlcArchiveNetTxBwUtilizationread-onlymandatoryNet Tx Bandwidth Utilization in the interval.
1.3.6.1.4.1.300.200.4.4.1.12ColumndlcArchiveNetTxPacketsread-onlymandatoryNet Tx Packets in the interval.
1.3.6.1.4.1.300.200.5NodedlcUnitTest
1.3.6.1.4.1.300.200.5NodemanualConfigChangeGenerated when the configuration was changed manually on the unit.
1.3.6.1.4.1.300.200.5.1TabledlcUnitTestTablenot-accessiblemandatoryA table containing all currently active tests. The initial release of the product's firmware does not include multiple tests. However, a later version will all…
1.3.6.1.4.1.300.200.5.1.1RowdlcUnitTestEntrynot-accessiblemandatoryAn entry in the network configuration table.
1.3.6.1.4.1.300.200.5.1.1.1ColumndlcUnitTestPortIdread-onlymandatoryIdentifies a port that a test might be running on. By convention, Self Test and all full-bandwidth tests (loopbacks, patterns, etc.) are assigned to the netPor…
1.3.6.1.4.1.300.200.5.1.1.2ColumndlcUnitTestTyperead-writemandatorySays what test is running on this port. Note that the following test nomenclature is equivalent: SNMP Terminal UI Front Panel 1in8 1:7 1:7 3in24 3:24 3.24 1in1…
1.3.6.1.4.1.300.200.5.1.1.3ColumndlcUnitTestPatternStatusread-onlymandatoryThe current state of the Pattern Test module.
1.3.6.1.4.1.300.200.5.1.1.4ColumndlcUnitTestPatternErrorsread-writemandatoryAn ongoing count of errors detected by the Pattern Generator/Detector. Can be read and written (to zero).
1.3.6.1.4.1.300.200.5.1.1.5ColumndlcLinkTestSentPacketsread-onlymandatoryNumber of sent packets for the currently running link based test.
1.3.6.1.4.1.300.200.5.1.1.6ColumndlcLinkTestReceivedPacketsread-onlymandatoryNumber of good received packets for the currently running link based test.
1.3.6.1.4.1.300.200.5.1.1.7ColumndlcLinkTestErroredPacketsread-onlymandatoryNumber of errored received packets for the currently running link based test.
1.3.6.1.4.1.300.200.5.1.1.8ColumndlcLinkTestMissingPacketsread-onlymandatoryNumber of missing packets for the currently running link based test.
1.3.6.1.4.1.300.200.5.1.1.9ColumndlcLinkTestAverageRoundTripread-onlymandatoryAverage round trip time in milli seconds for the currently running link based test.
1.3.6.1.4.1.300.200.5.1.1.10ColumndlcLinkTestMaximumRoundTripread-onlymandatoryMaximum round trip time in milli seconds for the currently running link based test.
1.3.6.1.4.1.300.200.6NodedlcUnitDelayMonitorStatus
1.3.6.1.4.1.300.200.6.1TabledlcDelayMonitorStatusTablenot-accessiblemandatoryTable of Delay Monitor status.
1.3.6.1.4.1.300.200.6.1.1RowdlcDelayMonitorStatusEntrynot-accessiblemandatoryAn entry in the network configuration table.
1.3.6.1.4.1.300.200.6.1.1.1ColumndlcDelayMonitorStatusIndexread-onlymandatoryUniquely identifies which Delay Monitor test in the configuration table.
1.3.6.1.4.1.300.200.6.1.1.2ColumndlcDelayMonitorSentPacketsread-onlymandatoryNumber of sent packets for the currently running delay monitor test.
1.3.6.1.4.1.300.200.6.1.1.3ColumndlcDelayMonitorReceivedPacketsread-onlymandatoryNumber of good received packets for the currently running delay monitor test.
1.3.6.1.4.1.300.200.6.1.1.4ColumndlcDelayMonitorErroredPacketsread-onlymandatoryNumber of errored received packets for the currently running delay monitor test.
1.3.6.1.4.1.300.200.6.1.1.5ColumndlcDelayMonitorMissingPacketsread-onlymandatoryNumber of missing packets for the currently running delay monitor test.
1.3.6.1.4.1.300.200.6.1.1.6ColumndlcDelayMonitorAverageRoundTripread-onlymandatoryAverage round trip time in milli seconds for the currently running delay monitor test.
1.3.6.1.4.1.300.200.6.1.1.7ColumndlcDelayMonitorMaximumRoundTripread-onlymandatoryMaximum round trip time in milli seconds for the currently running delay monitor test.
1.3.6.1.4.1.300.200.7TabledlcUtilizationTablenot-accessiblemandatoryTable for lifetime Utilization statistics.
1.3.6.1.4.1.300.200.7.1RowdlcUtilTableEntrynot-accessiblemandatoryAn entry for the utilization table.
1.3.6.1.4.1.300.200.7.1.1ColumndlcUtilDLCINumberread-onlymandatoryIdentifies the DLCI number of the utilization statistics of this entry/row.
1.3.6.1.4.1.300.200.7.1.2ColumndlcUtilEncodedValueread-onlymandatoryThis object represents the value of the whole row of the table. The intent of object is to increase the efficiency of retrieving the table. For each object val…
1.3.6.1.4.1.300.200.7.1.3ColumndlcUtilTimestampread-onlymandatoryIdentifies timestamp when this entry is last updated.
1.3.6.1.4.1.300.200.7.1.4ColumndlcUtilLessThan20read-onlymandatoryThe number of times utilization is less than 20% of Committed Information Rate (CIR).
1.3.6.1.4.1.300.200.7.1.5ColumndlcUtil20-40read-onlymandatoryThe number of times utilization is between 20% and 40% of Committed Information Rate (CIR).
1.3.6.1.4.1.300.200.7.1.6ColumndlcUtil40-60read-onlymandatoryThe number of times utilization is between 40% and 60% of Committed Information Rate (CIR).
1.3.6.1.4.1.300.200.7.1.7ColumndlcUtil60-80read-onlymandatoryThe number of times utilization is between 60% and 80% of Committed Information Rate (CIR).
1.3.6.1.4.1.300.200.7.1.8ColumndlcUtil80-100read-onlymandatoryThe number of times utilization is between 80% and 100% of Committed Information Rate (CIR).
1.3.6.1.4.1.300.200.7.1.9ColumndlcUtilMoreThan100read-onlymandatoryThe number of times utilization is more than 100% of Committed Information Rate (CIR).
Type Definitions
NameSyntaxStatusDescription
AlarmTypeINTEGER { lostSignal ( 1), lostSync ( 2), detectedYellow ( 3), detectedAIS ( 4), detectedExternalAlarm ( 5), exceededBpvThreshold ( 6), exceededOofThreshold ( 7), exceededCrcThreshold ( 8), remoteAlarmBitSet ( 9), detectedPSfailure (10), detectedCntlCardMissing (11), lostDlcFdlLink (12), exceededIbCrcThreshold (13), lostDlcInbandLink (14), lmiSpoofing (15) }
BooleanINTEGER { true (1), false (2) }
FramedUnframedINTEGER { framed (1), unframed (2) }
LoopCodeTypeINTEGER { standard (1), alternate (2), v54 (3), reserved1 (4), reserved2 (5), reserved3 (6), disable (7) }
MacAddressOCTET STRING (SIZE (6))
PortIdINTEGER { mainNet ( 1), aux ( 2), otherNet ( 3), reserved1 ( 4), reserved2 ( 5), reserved3 ( 6), ethPort ( 7), commPort ( 8), int-clock ( 9), ext-clock (10), data1 (11), data2 (12), data3 (13), data4 (14), data5 (15), data6 (16), data7 (17), data8 (18), data9 (19), data10 (20), data11 (21), data12 (22), data13 (23), data14 (24), data15 (25), data16 (26), data17 (27), data18 (28), data19 (29), data20 (30), data21 (31), data22 (32), data23 (33), data24 (34), data25 (35), data26 (36), data27 (37), data28 (38), data29 (39), data30 (40), data31 (41), data32 (42), noPort (43) }
PortStatusItemINTEGER { normal ( 1), lossOfSignal ( 2), lossOfSync ( 3), yellowAlarmDetected ( 4), blueAlarmDetected ( 5), setCodeReceived ( 6), resetCodeReceived ( 7), excessiveErrorRate ( 8), localTest ( 9), eBitReceived (10), reserved1 (11), reserved2 (12), reserved3 (13), reserved4 (14) }
RemoteCommunicationsModeINTEGER { none (1), digital-link (2), att-TR54016 (3), ansi-T1-403 (4) }
TestTypeINTEGER { noTest ( 1), selfTest ( 2), netLoopback ( 3), payloadLoopback ( 4), dteLoopback ( 5), loopUpRemote ( 6), loopDownRemote ( 7), sendQrwPattern ( 8), send1in8Pattern ( 9), send1in1Pattern (10), send1in3Pattern (11), send1in5Pattern (12), send2in3Pattern (14), send4in5Pattern (15), send3in24Pattern (16), sendAllOnePattern (17), sendAllZeroPattern (18), sendUser1Pattern (19), sendUser2Pattern (20), sendSmartJackSet (21), sendSmartJackReset (22), sendAPatternError (23), dteNetLoopback (24), reserved1 (25), reserved2 (26), reserved3 (27), reserved4 (28), reserved5 (29), reserved6 (30), lampTest (31) }
UnitStatusItemINTEGER { normal ( 1), noClock ( 2), testInProgress ( 4), sendKeepAlive ( 8), sendYellowAlarm ( 16), reserved1 ( 32), reserved2 ( 64), reserved3 (128), reserved4 (256), reserved5 (512) }