EDGE-MIB
88 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.429 | Nodeusr | |||
| 1.3.6.1.4.1.429.1 | Nodenas | |||
| 1.3.6.1.4.1.429.1.24 | Nodeedge | |||
| 1.3.6.1.4.1.429.1.24.1 | NodeedgeServerStat | |||
| 1.3.6.1.4.1.429.1.24.1.1 | TableedgeServerStatTable | not-accessible | mandatory | Table containing objects for statistics for the EdgeServer Gateway Cards in the chassis. |
| 1.3.6.1.4.1.429.1.24.1.1.1 | RowedgeServerStatEntry | not-accessible | mandatory | There is one Configuration row for each Gateway Card in the NAS chassis. |
| 1.3.6.1.4.1.429.1.24.1.1.1.1 | ColumnedgeSsIndex | read-only | mandatory | A unique index identifying the Gateway Card to which the EdgeServer statistics table objects pertain |
| 1.3.6.1.4.1.429.1.24.1.1.1.2 | ColumnedgeSsProcessorTime | read-only | mandatory | This object gives the Time the CPU spen executing non-idle thread. |
| 1.3.6.1.4.1.429.1.24.1.1.1.3 | ColumnedgeSsInterruptPerSec | read-only | mandatory | This object is the number of interrupts received and servicced per second. |
| 1.3.6.1.4.1.429.1.24.1.1.1.4 | ColumnedgeSsDiskPercentUsed | read-only | mandatory | This object is the Percent of the Disk used Space. |
| 1.3.6.1.4.1.429.1.24.1.1.1.5 | ColumnedgeSsFreeMegabytes | read-only | mandatory | This object is the unallocated space on drive. |
| 1.3.6.1.4.1.429.1.24.1.1.1.6 | ColumnedgeSsPercentDiskTime | read-only | mandatory | This object is the percent of time disk is busy servicing read/write requests. |
| 1.3.6.1.4.1.429.1.24.1.1.1.7 | ColumnedgeSsPercentDiskReadTime | read-only | mandatory | This object is the percent of time disk is busy servicing read requests. |
| 1.3.6.1.4.1.429.1.24.1.1.1.8 | ColumnedgeSsPercentDiskWriteTime | read-only | mandatory | This object is the percent of time disk is busy servicing write requests. |
| 1.3.6.1.4.1.429.1.24.1.1.1.9 | ColumnedgeSsMemoryPercentUsed | read-only | mandatory | This object is the physical Used percentage of memory. |
| 1.3.6.1.4.1.429.1.24.1.1.1.10 | ColumnedgeSsPageFaultsPerSec | read-only | mandatory | This object is the Rate of faulted pages handled by processor per second. |
| 1.3.6.1.4.1.429.1.24.1.1.1.11 | ColumnedgeSsInfrastructManufacturer | read-only | mandatory | This object is the Customer Identifier. |
| 1.3.6.1.4.1.429.1.24.1.1.1.12 | ColumnedgeSsedgeTechnology | read-only | mandatory | This object is the edge Technology used on the NAC. |
| 1.3.6.1.4.1.429.1.24.1.1.1.13 | ColumnedgeSsCurrentSwLoadRevision | read-only | mandatory | This object is the current revision of the Software load. |
| 1.3.6.1.4.1.429.1.24.1.1.1.14 | ColumnedgeSsPreviousSwLoadRevision | read-only | mandatory | This object is the previous revision of the Software load. |
| 1.3.6.1.4.1.429.1.24.1.1.1.15 | ColumnedgeSsHwLoadRevision | read-only | mandatory | This object is the revision of the Hardware Load. |
| 1.3.6.1.4.1.429.1.24.1.1.1.16 | ColumnedgeSsComputerName | read-write | mandatory | This object is the Windows NT Computer Name |
| 1.3.6.1.4.1.429.1.24.1.1.1.17 | ColumnedgeSsSysUpTime | read-only | mandatory | This object is the EdgeServer System Up Time in Minutes. |
| 1.3.6.1.4.1.429.1.24.2 | NodeedgeCfgDebugLevel | |||
| 1.3.6.1.4.1.429.1.24.2.1 | TableedgeCfgDebugLevelTable | not-accessible | mandatory | Table containing objects for configuring Debug Levels for EdgeServer Gateway Cards in the chassis. |
| 1.3.6.1.4.1.429.1.24.2.1.1 | RowedgeCfgDebugLevelEntry | not-accessible | mandatory | There is one Configuration row for each Gateway Card in the NAS chassis. |
| 1.3.6.1.4.1.429.1.24.2.1.1.1 | ColumnedgeCfgDbgIndex | read-only | mandatory | A unique index identifying the Gateway Card to which the Debug Level parameters table objects pertain |
| 1.3.6.1.4.1.429.1.24.2.1.1.2 | ColumnedgeCfgDbgIp | read-write | mandatory | This object configures the Debug Level for Ip Debug Systems. |
| 1.3.6.1.4.1.429.1.24.2.1.1.3 | ColumnedgeCfgDbgPPP | read-write | mandatory | This object configures the Debug Level for PPP Debug Systems. |
| 1.3.6.1.4.1.429.1.24.2.1.1.4 | ColumnedgeCfgDbgTDM | read-write | mandatory | This object configures the Debug Level for TDM Debug Systems. |
| 1.3.6.1.4.1.429.1.24.2.1.1.5 | ColumnedgeCfgDbgFrameService | read-write | mandatory | This object configures the Debug Level for Frame Service Debug Systems. |
| 1.3.6.1.4.1.429.1.24.2.1.1.6 | ColumnedgeCfgDbgPacketBus | read-write | mandatory | This object configures the Debug Level for Packet Bus Debug Systems. |
| 1.3.6.1.4.1.429.1.24.2.1.1.7 | ColumnedgeCfgDbgCallControl | read-write | mandatory | This object configures the Debug Level for Call Control Debug Systems. |
| 1.3.6.1.4.1.429.1.24.2.1.1.8 | ColumnedgeCfgDbgDataTransfer | read-write | mandatory | This object configures the Debug Level for Data Transfer Debug Systems. |
| 1.3.6.1.4.1.429.1.24.2.1.1.9 | ColumnedgeCfgDbgCompression | read-write | mandatory | This object configures the Debug Level for Compression Debug Systems. |
| 1.3.6.1.4.1.429.1.24.3 | NodeedgeMemUtlTrap | |||
| 1.3.6.1.4.1.429.1.24.3.1 | TableedgeMemUtlTrapTable | not-accessible | mandatory | Table containing objects for Memory Utilization Trap for EdgeServer Gateway Cards in the chassis. |
| 1.3.6.1.4.1.429.1.24.3.1.1 | RowedgeMemUtlTrapEntry | not-accessible | mandatory | There is one Operational row for each Gateway Card in the NAS chassis. |
| 1.3.6.1.4.1.429.1.24.3.1.1.1 | ColumnedgeMemUtlTrIndex | read-only | mandatory | A unique index identifying the Gateway Card to which the Memory Utilization Trap objects pertain |
| 1.3.6.1.4.1.429.1.24.3.1.1.2 | ColumnedgeMemUtlTrMrgOperStatus | read-write | mandatory | This object is the operational Memory Utilization status Marginally operational trap enable/disable. |
| 1.3.6.1.4.1.429.1.24.3.1.1.3 | ColumnedgeMemUtlTrNonOperStatus | read-write | mandatory | This object is the operational Memory Utilization status Non operational trap enable/disable. |
| 1.3.6.1.4.1.429.1.24.3.1.1.4 | ColumnedgeMemUtlTrClearStatus | read-write | mandatory | This object is the operatinal Memory Utilization status Clear trap enable/disable. |
| 1.3.6.1.4.1.429.1.24.3.1.1.5 | ColumnedgeMemUtlTrMrgOperThreshCnt | read-write | mandatory | This object is the Memory Utilization Marginally Operational Trap Threshold Count. |
| 1.3.6.1.4.1.429.1.24.3.1.1.6 | ColumnedgeMemUtlTrNonOperThreshCnt | read-write | mandatory | This object is the Memory Utilization Non Operational Trap Threshold Count. |
| 1.3.6.1.4.1.429.1.24.3.1.1.7 | ColumnedgeMemUtlTrClearThreshCnt | read-write | mandatory | This object is the Memory Utilization Clear Trap Threshold Count. |
| 1.3.6.1.4.1.429.1.24.3.1.1.8 | ColumnedgeMemUtlTrMrgOperThreshTimer | read-write | mandatory | This object is the Memory Utilization Marginally Operational Trap Threshold Time. |
| 1.3.6.1.4.1.429.1.24.3.1.1.9 | ColumnedgeMemUtlTrNonOperThreshTimer | read-write | mandatory | This object is the Memory Utilization Non Operational Trap Threshold Time. |
| 1.3.6.1.4.1.429.1.24.3.1.1.10 | ColumnedgeMemUtlTrClearThreshTimer | read-write | mandatory | This object is the Memory Utilization Clear Trap Threshold Time. |
| 1.3.6.1.4.1.429.1.24.3.1.1.11 | ColumnedgeMemUtlTrStatus | read-only | mandatory | This object is the Status of the Memory utilization trap. |
| 1.3.6.1.4.1.429.1.24.4 | NodeedgeCpuUtlTrap | |||
| 1.3.6.1.4.1.429.1.24.4.1 | TableedgeCpuUtlTrapTable | not-accessible | mandatory | Table containing objects for CPU Utilization Trap for EdgeServer Gateway Cards in the chassis. |
| 1.3.6.1.4.1.429.1.24.4.1.1 | RowedgeCpuUtlTrapEntry | not-accessible | mandatory | There is one Operational row for each Gateway Card in the NAS chassis. |
| 1.3.6.1.4.1.429.1.24.4.1.1.1 | ColumnedgeCpuUtlTrIndex | read-only | mandatory | A unique index identifying the Gateway Card to which the CPU Utilization Trap objects pertain |
| 1.3.6.1.4.1.429.1.24.4.1.1.2 | ColumnedgeCpuUtlTrMrgOperStatus | read-write | mandatory | This object is see the current operation of the CPU Utilization status Marginally operational trap enable/disable. |
| 1.3.6.1.4.1.429.1.24.4.1.1.3 | ColumnedgeCpuUtlTrNonOperStatus | read-write | mandatory | This object is to see the curent operation of the CPU Utilization status Non operational trap enable/disable. |
| 1.3.6.1.4.1.429.1.24.4.1.1.4 | ColumnedgeCpuUtlTrClearStatus | read-write | mandatory | This object is to see the current operation the CPU Utilization status Clear trap enable/disable. |
| 1.3.6.1.4.1.429.1.24.4.1.1.5 | ColumnedgeCpuUtlTrMrgOperThreshCnt | read-write | mandatory | This object is the CPU Utilization Marginally Operational Trap Threshold Count. |
| 1.3.6.1.4.1.429.1.24.4.1.1.6 | ColumnedgeCpuUtlTrNonOperThreshCnt | read-write | mandatory | This object is the CPU Utilization Non Operational Trap Threshold Count. |
| 1.3.6.1.4.1.429.1.24.4.1.1.7 | ColumnedgeCpuUtlTrClearThreshCnt | read-write | mandatory | This object is the CPU Utilization Clear Trap Threshold Count. |
| 1.3.6.1.4.1.429.1.24.4.1.1.8 | ColumnedgeCpuUtlTrMrgOperThreshTimer | read-write | mandatory | This object is the CPU Utilization Marginally Operational Trap Threshold Time. |
| 1.3.6.1.4.1.429.1.24.4.1.1.9 | ColumnedgeCpuUtlTrNonOperThreshTimer | read-write | mandatory | This object is the CPU Utilization Non Operational Trap Threshold Time. |
| 1.3.6.1.4.1.429.1.24.4.1.1.10 | ColumnedgeCpuUtlTrClearThreshTimer | read-write | mandatory | This object is the CPU Utilization Clear Trap Threshold Time. |
| 1.3.6.1.4.1.429.1.24.4.1.1.11 | ColumnedgeCpuUtlTrStatus | read-only | mandatory | This object is the CPU Utilization trap status. |
| 1.3.6.1.4.1.429.1.24.5 | NodeedgeDskUtlTrap | |||
| 1.3.6.1.4.1.429.1.24.5.1 | TableedgeDskUtlTrapTable | not-accessible | mandatory | Table containing objects for DISK Utilization Trap for EdgeServer Gateway Cards in the chassis. |
| 1.3.6.1.4.1.429.1.24.5.1.1 | RowedgeDskUtlTrapEntry | not-accessible | mandatory | There is one Operational row for each Gateway Card in the NAS chassis. |
| 1.3.6.1.4.1.429.1.24.5.1.1.1 | ColumnedgeDskUtlTrIndex | read-only | mandatory | A unique index identifying the Gateway Card to which the DISK Utilization Trap objects pertain |
| 1.3.6.1.4.1.429.1.24.5.1.1.2 | ColumnedgeDskUtlTrMrgOperStatus | read-write | mandatory | This object is see the current setting of the DISK Utilization status Marginally operational trap enable/disable. |
| 1.3.6.1.4.1.429.1.24.5.1.1.3 | ColumnedgeDskUtlTrNonOperStatus | read-write | mandatory | This object is to see the current setting of the DISK Utilization status Non operational trap enable/disable. |
| 1.3.6.1.4.1.429.1.24.5.1.1.4 | ColumnedgeDskUtlTrClearStatus | read-write | mandatory | This object is to see the current operational setting of the DISK Utilization status Clear trap enable/disable. |
| 1.3.6.1.4.1.429.1.24.5.1.1.5 | ColumnedgeDskUtlTrMrgOperThreshCnt | read-write | mandatory | This object is the DISK Utilization Marginally Operational Trap Threshold Count. |
| 1.3.6.1.4.1.429.1.24.5.1.1.6 | ColumnedgeDskUtlTrNonOperThreshCnt | read-write | mandatory | This object is the DISK Utilization Non Operational Trap Threshold Count. |
| 1.3.6.1.4.1.429.1.24.5.1.1.7 | ColumnedgeDskUtlTrClearThreshCnt | read-write | mandatory | This object is the DISK Utilization Clear Trap Threshold Count. |
| 1.3.6.1.4.1.429.1.24.5.1.1.8 | ColumnedgeDskUtlTrMrgOperThreshTimer | read-write | mandatory | This object is the DISK Utilization Marginally Operational Trap Threshold Time. |
| 1.3.6.1.4.1.429.1.24.5.1.1.9 | ColumnedgeDskUtlTrNonOperThreshTimer | read-write | mandatory | This object is the DISK Utilization Non Operational Trap Threshold Time. |
| 1.3.6.1.4.1.429.1.24.5.1.1.10 | ColumnedgeDskUtlTrClearThreshTimer | read-write | mandatory | This object is the DISK Utilization Clear Trap Threshold Time. |
| 1.3.6.1.4.1.429.1.24.5.1.1.11 | ColumnedgeDskUtlTrStatus | read-only | mandatory | This object is the DISK Utilization trap status. |
| 1.3.6.1.4.1.429.1.24.6 | NodeedgeCmd | |||
| 1.3.6.1.4.1.429.1.24.6.1 | TableedgeCmdTable | not-accessible | mandatory | The IP Card Command table contains an entry for each of the manageable IP Gateway Card in the chassis. It provides a means through which to take specific actio… |
| 1.3.6.1.4.1.429.1.24.6.1.1 | RowedgeCmdEntry | not-accessible | mandatory | There is one IP Gateway Card Command entry per IP Gateway Card in the chassis. |
| 1.3.6.1.4.1.429.1.24.6.1.1.1 | ColumnedgeCmdIndex | read-only | mandatory | A unique value for each IP Gateway Card in the chassis. The value of this object matches the value of the index of the correspond1ing IP Gateway Card's entry i… |
| 1.3.6.1.4.1.429.1.24.6.1.1.2 | ColumnedgeCmdMgtStationId | read-write | mandatory | This object is a generic read-write variable that a Management Station (MS) can use to guarantee that the results from a given command are the results of a com… |
| 1.3.6.1.4.1.429.1.24.6.1.1.3 | ColumnedgeCmdReqId | read-only | mandatory | This object contains the value of the request-id field in the SNMP PDU which invoked the current or most recent command or test on this IP Gateway Card. If the… |
| 1.3.6.1.4.1.429.1.24.6.1.1.4 | ColumnedgeCmdFunction | read-write | mandatory | This object contains a value which describes the command which is being invoked. |
| 1.3.6.1.4.1.429.1.24.6.1.1.5 | ColumnedgeCmdForce | read-write | mandatory | In some cases, the IP Gateway Card may be in a state such that certain commands could adversely affect connections. In such cases, a command request with this … |
| 1.3.6.1.4.1.429.1.24.6.1.1.6 | ColumnedgeCmdParam | read-write | mandatory | This object contains parameters that are specific to the particular command being issued. In some cases, there will be no aditional parameters required. |
| 1.3.6.1.4.1.429.1.24.6.1.1.7 | ColumnedgeCmdResult | read-only | mandatory | This object contains the result of the most recently requested command or test, or the value none(1) if no commands have been requested since the last reset. |
| 1.3.6.1.4.1.429.1.24.6.1.1.8 | ColumnedgeCmdCode | read-only | mandatory | The value of this object upon command completion indicates a further description of what went wrong if the command was unsuccessful. In the case of tests, a bi… |