EMPIRE-CACUCSEXTENSIONA-MIB
556 objects
This MIB module defines the Cisco Universal Computing System Aim extension tables.
Imported Objects
| EMPIRE | -- empire applications traps -- |
| IANAifType-MIB | IANAifType |
| INET-ADDRESS-MIB | InetAddress InetAddressType |
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | -- enterprises -- |
| RFC1213-MIB | PhysAddress |
| SNMPv2-SMI | Counter32 Counter64 enterprises Gauge32 Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE TimeTicks Unsigned32 |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION TruthValue |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.546 | Nodeempire | |||
| 1.3.6.1.4.1.546.1 | Nodeunix | |||
| 1.3.6.1.4.1.546.1.1 | Nodesysmgmt | |||
| 1.3.6.1.4.1.546.1.1.165526 | NotificationcaUcsChassisFabricExtenderRemovedTrap | current | A fabric extender module has been removed from a chassis. | |
| 1.3.6.1.4.1.546.1.1.165527 | NotificationcaUcsChassisFabricExtenderPortFailureTrap | current | A port on a fabric extender has failed due to hardware failure. | |
| 1.3.6.1.4.1.546.1.1.165528 | NotificationcaUcsChassisFabricExtenderPortLinkDownTrap | current | A port on a fabric extender has lost its link. | |
| 1.3.6.1.4.1.546.9 | Nodetraps | |||
| 1.3.6.1.4.1.546.9.165526 | NodecaUcsChassisFabricExtenderRemovedEvent | |||
| 1.3.6.1.4.1.546.9.165527 | NodecaUcsChassisFabricExtenderPortFailureEvent | |||
| 1.3.6.1.4.1.546.9.165528 | NodecaUcsChassisFabricExtenderPortLinkDownEvent | |||
| 1.3.6.1.4.1.546.16 | Nodeapplications | |||
| 1.3.6.1.4.1.546.16.58 | Nodecadatacentera | |||
| 1.3.6.1.4.1.546.16.58.3 | IdentitycaUcsExtensions | This MIB module defines the Cisco Universal Computing System Aim extension tables. | ||
| 1.3.6.1.4.1.546.16.58.3.1 | NodecaUcsChassisExt | |||
| 1.3.6.1.4.1.546.16.58.3.1.1 | NodecaUcsChassis | |||
| 1.3.6.1.4.1.546.16.58.3.1.1.1 | Scalarin | clause | current | caUcsChassis table. |
| 1.3.6.1.4.1.546.16.58.3.1.1.2 | ScalarcaUcsChassisTableLastChange | read-only | current | Table tast refresh time |
| 1.3.6.1.4.1.546.16.58.3.1.2 | NodecaUcsChassisFan | |||
| 1.3.6.1.4.1.546.16.58.3.1.2.1 | TablecaUcsChassisFanTable | not-accessible | current | caUcsChassisFan table. |
| 1.3.6.1.4.1.546.16.58.3.1.2.1.1 | RowcaUcsChassisFanEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.1.2.1.1.1 | ColumncaUcsChassisFanUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.1.2.1.1.2 | ColumncaUcsChassisFanChassisId | read-only | current | Instance of a chassis/enclosure; corresponds to caChassisId. |
| 1.3.6.1.4.1.546.16.58.3.1.2.1.1.3 | ColumncaUcsChassisFanIndex | read-only | current | Instance of a fan. |
| 1.3.6.1.4.1.546.16.58.3.1.2.1.1.4 | ColumncaUcsChassisFanAmbientTemp | read-only | current | Degrees celsius. |
| 1.3.6.1.4.1.546.16.58.3.1.2.1.1.5 | ColumncaUcsChassisFanOperState | read-only | current | Operational state of the fan. |
| 1.3.6.1.4.1.546.16.58.3.1.2.1.1.6 | ColumncaUcsChassisFanTray | read-only | current | The chassis trap containing the fan. |
| 1.3.6.1.4.1.546.16.58.3.1.2.1.1.7 | ColumncaUcsChassisFanModule | read-only | current | A module contained within a tray. |
| 1.3.6.1.4.1.546.16.58.3.1.2.1.1.8 | ColumncaUcsChassisFanId | read-only | current | The idntifier of the fan; may be the same as caChcssisFanIndex. |
| 1.3.6.1.4.1.546.16.58.3.1.2.1.1.9 | ColumncaUcsChassisFanOperability | read-only | current | Operability of the chassis fan. |
| 1.3.6.1.4.1.546.16.58.3.1.2.1.1.10 | ColumncaUcsChassisFanPerformance | read-only | current | Chassis fan performance |
| 1.3.6.1.4.1.546.16.58.3.1.2.1.1.11 | ColumncaUcsChassisFanPower | read-only | current | Chassis fan power status |
| 1.3.6.1.4.1.546.16.58.3.1.3 | NodecaUcsChassisPower | |||
| 1.3.6.1.4.1.546.16.58.3.1.3.1 | TablecaUcsChassisPsuTable | not-accessible | current | caUcsChassisPsu table. |
| 1.3.6.1.4.1.546.16.58.3.1.3.1.1 | RowcaUcsChassisPsuEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.1.3.1.1.1 | ColumncaUcsChassisPsuUcsManagerId | read-only | current | The configured switch to use for connectivity. |
| 1.3.6.1.4.1.546.16.58.3.1.3.1.1.2 | ColumncaUcsChassisPsuChassisId | read-only | current | Instance of a chassis/enclosure; corresponds to caChassisId. |
| 1.3.6.1.4.1.546.16.58.3.1.3.1.1.3 | ColumncaUcsChassisPsuIndex | read-only | current | Id unique within the context of the chassis. |
| 1.3.6.1.4.1.546.16.58.3.1.3.1.1.4 | ColumncaUcsChassisPsuAmbientTemp | read-only | current | Temperature, in celsius, sensed by the PSU. |
| 1.3.6.1.4.1.546.16.58.3.1.3.1.1.5 | ColumncaUcsChassisPsuOperState | read-only | current | Operational state of the fan. |
| 1.3.6.1.4.1.546.16.58.3.1.3.1.1.6 | ColumncaUcsChassisPsuInput210v | read-only | current | Actual voltage drawn by the PSU on the 210v input. |
| 1.3.6.1.4.1.546.16.58.3.1.3.1.1.7 | ColumncaUcsChassisPsuOutput12v | read-only | current | Actual volage put out by the PSU on the 12 volt rail(s). |
| 1.3.6.1.4.1.546.16.58.3.1.3.1.1.8 | ColumncaUcsChassisPsuOutput3v3 | read-only | current | Actual volage put out by the PSU on the 3.3 volt rail(s). |
| 1.3.6.1.4.1.546.16.58.3.1.3.1.1.9 | ColumncaUcsChassisPsuOperability | read-only | current | Operability of the fan. |
| 1.3.6.1.4.1.546.16.58.3.1.3.1.1.10 | ColumncaUcsChassisPsuPerformance | read-only | current | Chassis Psu performance |
| 1.3.6.1.4.1.546.16.58.3.1.3.1.1.11 | ColumncaUcsChassisPsuPower | read-only | current | Chassis Psu power status |
| 1.3.6.1.4.1.546.16.58.3.1.4 | NodecaUcsChassisFabricExtender | |||
| 1.3.6.1.4.1.546.16.58.3.1.4.1 | ScalarcaUcsChassisFabricExtenderTableLastChange | read-only | current | The value of sysUpTime at the time of the last creation or deletion of an entry in the caUcsChassisFabricExtenderTable. If the number of entries has been uncha… |
| 1.3.6.1.4.1.546.16.58.3.1.4.2 | TablecaUcsChassisFabricExtenderTable | not-accessible | current | caUcsChassisFabricExtender table. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1 | RowcaUcsChassisFabricExtenderEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.1 | ColumncaUcsChassisFabricExtenderUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.2 | ColumncaUcsChassisFabricExtenderChassisId | read-only | current | Instance of a chassis/enclosure; corresponds to caChassisId. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.3 | ColumncaUcsChassisFabricExtenderSlotId | read-only | current | Instance of a fabric extender and the slot in which it is installed. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.4 | ColumncaUcsChassisFabricExtenderModel | read-only | current | Model of the fabric extender. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.5 | ColumncaUcsChassisFabricExtenderSerialNumber | read-only | current | Serial number of the fabric extender. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.6 | ColumncaUcsChassisFabricExtenderVendor | read-only | current | Vendor of the fabric extender. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.7 | ColumncaUcsChassisFabricExtenderRevision | read-only | current | Revision of the model of the fabric extender. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.8 | ColumncaUcsChassisFabricExtenderSide | read-only | current | Side of the chassis in which the fabric extender is installed. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.9 | ColumncaUcsChassisFabricExtenderAmbientTemp | read-only | current | Degrees celsius. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.10 | ColumncaUcsChassisFabricExtenderOperState | read-only | current | Operational state of the fabric extender. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.11 | ColumncaUcsChassisFabricExtenderBootLoaderVersion | read-only | current | Version of the boot loader firmware that is running currently. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.12 | ColumncaUcsChassisFabricExtenderFirmwareVersion | read-only | current | Version of the firmware that is currently running. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.13 | ColumncaUcsChassisFabricExtenderStartupFirmwareVersion | read-only | current | Startup version of the firmware. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.14 | ColumncaUcsChassisFabricExtenderBackupFirmwareVersion | read-only | current | Backup version of the firmware. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.15 | ColumncaUcsChassisFabricExtenderOperability | read-only | current | Operability of the fabric extender. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.16 | ColumncaUcsChassisFabricExtenderProductName | read-only | current | Product name of the fabric extender. |
| 1.3.6.1.4.1.546.16.58.3.1.4.2.1.17 | ColumncaUcsChassisFabricExtenderPid | read-only | current | Pid of the fabric extender. |
| 1.3.6.1.4.1.546.16.58.3.1.4.3 | ScalarcaUcsChassisFabricExtenderPortTableLastChange | read-only | current | The value of sysUpTime at the time of the last creation or deletion of an entry in the caUcsChassisFabricExtenderPortTable. If the number of entries has been u… |
| 1.3.6.1.4.1.546.16.58.3.1.4.4 | TablecaUcsChassisFabricExtenderPortTable | not-accessible | current | caUcsChassisFabricExtenderPort table. |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1 | RowcaUcsChassisFabricExtenderPortEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.1 | ColumncaUcsChassisFabricExtenderPortUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.2 | ColumncaUcsChassisFabricExtenderPortChassisId | read-only | current | Instance of a chassis/enclosure; corresponds to caChassisId. |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.3 | ColumncaUcsChassisFabricExtenderPortIndex | read-only | current | Instance of a port on a fabric extender. |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.4 | ColumncaUcsChassisFabricExtenderPortSlotId | read-only | current | Instance of a fabric extender and the slot in which it is installed. |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.5 | ColumncaUcsChassisFabricExtenderPortModel | read-only | current | Model of the fabric extender port. |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.6 | ColumncaUcsChassisFabricExtenderPortSerialNumber | read-only | current | Serial number of the fabric extender port. |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.7 | ColumncaUcsChassisFabricExtenderPortVendor | read-only | current | Vendor of the fabric extender port. |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.8 | ColumncaUcsChassisFabricExtenderPortRevision | read-only | current | Revision of the model of the fabric extender port. |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.9 | ColumncaUcsChassisFabricExtenderPortType | read-only | current | What type of port this represents. |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.10 | ColumncaUcsChassisFabricExtenderDeviceIndex | read-only | current | The device connected to this fabric extender port. Connected devices, if known, are either a switch or a blade. If this is a switch port, this is the value of … |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.11 | ColumncaUcsChassisFabricExtenderConnectedPortIndex | read-only | current | The port of the device connected to this fabric extender port. If this is a switch port, then this is the index into the caSwitchInterfaceTable. If this is a s… |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.12 | ColumncaUcsChassisFabricExtenderPortOperState | read-only | current | operating state of the extender port |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.13 | ColumncaUcsChassisFabricExtenderPortPeerSlotId | read-only | current | Peer slot id of the fabric extender port |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.14 | ColumncaUcsChassisFabricExtenderPortAcknowledge | read-only | current | Only available for fabric not for host port |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.15 | ColumncaUcsChassisFabricExtenderPortPeerDn | read-only | current | Peer Dn |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.16 | ColumncaUcsChassisFabricExtenderPortProductName | read-only | current | Product name of the extender port |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.17 | ColumncaUcsChassisFabricExtenderPortPid | read-only | current | Pid of the extender port |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.18 | ColumncaUcsChassisFabricExtenderPortPeerFullyQualifiedDn | read-only | current | Peer fully qualified Dn |
| 1.3.6.1.4.1.546.16.58.3.1.4.4.1.19 | ColumncaUcsChassisFabricExtenderPortSwitchId | read-only | current | switch id that port is connected to |
| 1.3.6.1.4.1.546.16.58.3.2 | NodecaUcsBladeExt | |||
| 1.3.6.1.4.1.546.16.58.3.2.1 | NodecaUcsBlade | |||
| 1.3.6.1.4.1.546.16.58.3.2.1.1 | TablecaUcsBladeTable | not-accessible | current | caUCSBlade table. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1 | RowcaUcsBladeEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.1 | ColumncaUcsBladeUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.2 | ColumncaUcsBladeIndex | read-only | current | Instance of a blade in a chassis. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.3 | ColumncaUcsBladeOperState | read-only | current | Operational state of the blade. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.4 | ColumncaUcsBladeBootLoaderFirmwareVersion | read-only | current | Version of the boot loader firmware that is running currently. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.5 | ColumncaUcsBladeSystemFirmwareVersion | read-only | current | Version of the system firmware. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.6 | ColumncaUcsBladeBackupFirmwareVersion | read-only | current | Backup version of the system firmware. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.7 | ColumncaUcsBladeBiosVersion | read-only | current | Current running version of the BIOS. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.8 | ColumncaUcsBladeRestartBiosVersion | read-only | current | Version of the BIOS that will be loaded at reboot. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.9 | ColumncaUcsBladeBiosBootSequence | read-only | current | Sequence of devices the BIOS uses to find a boot image, separated by commas. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.10 | ColumncaUcsBladeNumOfAdaptors | read-only | current | Number of mezzanine cards in the blade. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.11 | ColumncaUcsBladeNumOfCpus | read-only | current | Number of CPUs installed on the blade. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.12 | ColumncaUcsBladeNumOfCores | read-only | current | Total number of cores across all CPUs on the blade. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.13 | ColumncaUcsBladeNumOfEthernetIfs | read-only | current | Total number of Ethernet interfaces as seen by software hosted on the blade. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.14 | ColumncaUcsBladeNumOfFcIfs | read-only | current | Total number of Fibre Channel interfaces as seen by software hosted on the blade. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.15 | ColumncaUcsBladeAvailableMemory | read-only | current | Available memory in MBs. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.16 | ColumncaUcsBladeCachedMemory | read-only | current | Cached memory in MBs. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.17 | ColumncaUcsBladeTotalMemory | read-only | current | Total memory in MBs. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.18 | ColumncaUcsBladeAvailableSwapMemory | read-only | current | Available swap memory in MBs. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.19 | ColumncaUcsBladeCachedSwapMemory | read-only | current | Cached swap memory in MBs. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.20 | ColumncaUcsBladeTotalSwapMemory | read-only | current | Total swap memory in MBs. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.21 | ColumncaUcsBladeAssignedToDn | read-only | current | This DN is used for power up/down operation. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.22 | ColumncaUcsBladeOperability | read-only | current | Operability of the blade. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.23 | ColumncaUcsBladeDiscovery | read-only | current | Discovery status of the blade |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.24 | ColumncaUcsBladeNumOfThreads | read-only | current | Total number of CPU threads |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.25 | ColumncaUcsBladeOperPower | read-only | current | Operating power of the blade. |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.26 | ColumncaUcsBladeOperQualifier | read-only | current | Blade configuration error |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.27 | ColumncaUcsBladeAdminState | read-only | current | Admin state of the blade |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.28 | ColumncaUcsBladeAvailableState | read-only | current | Availability of the blade |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.29 | ColumncaUcsBladeAssociateState | read-only | current | Service profile association state |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.30 | ColumncaUcsBladeSlotStatus | read-only | current | Slot status of the blade |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.31 | ColumncaUcsBladeCheckPoint | read-only | current | Checkpoint |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.32 | ColumncaUcsBladeAssignedToFullyQualifiedDn | read-only | current | This fully qualified DN |
| 1.3.6.1.4.1.546.16.58.3.2.1.1.1.33 | ColumncaUcsBladeServiceProfileOid | read-only | current | Reference service profile index <UCS Manager Id>,<Service Profile internal id> with full OID path |
| 1.3.6.1.4.1.546.16.58.3.2.1.2 | ScalarcaUcsBladeTableLastChange | read-only | current | Table tast refresh time |
| 1.3.6.1.4.1.546.16.58.3.2.2 | NodecaUcsBladeInterfaces | |||
| 1.3.6.1.4.1.546.16.58.3.2.2.1 | TablecaUcsBladeIfTable | not-accessible | current | caUcsBladeIf table. |
| 1.3.6.1.4.1.546.16.58.3.2.2.1.1 | RowcaUcsBladeIfEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.2.1.1.1 | ColumncaUcsBladeIfUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.2.1.1.2 | ColumncaUcsBladeIfBladeIndex | read-only | current | Index of the blade from the caBladeTable. |
| 1.3.6.1.4.1.546.16.58.3.2.2.1.1.3 | ColumncaUcsBladeIfIndex | read-only | current | Index of an interface on a blade; corresponds to caBladeIfIndex. |
| 1.3.6.1.4.1.546.16.58.3.2.2.1.1.4 | ColumncaUcsBladeIfFirmwareVersion | read-only | current | Version of the firmware that is currently running or a zero-length string if the value is not known or does not apply. |
| 1.3.6.1.4.1.546.16.58.3.2.2.1.1.5 | ColumncaUcsBladeIfStartupFirmwareVersion | read-only | current | Startup version of the firmware or a zero-length string if the value is not known or does not apply. |
| 1.3.6.1.4.1.546.16.58.3.2.2.1.1.6 | ColumncaUcsBladeIfFabricExtenderSlotId | read-only | current | The value of caUcsFabricExtenderSlotId connected to this particular port or 0 if the port is not a backplane port. |
| 1.3.6.1.4.1.546.16.58.3.2.2.1.1.7 | ColumncaUcsBladeIfFabricExtenderPortIndex | read-only | current | The value of caUcsFabricExtenderPortIndex connected to this particular port or 0 if the port is not a backplane port. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2 | TablecaUcsBladeIfEthStatsTable | not-accessible | current | caUcsBladeIfEthStats table. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1 | RowcaUcsBladeIfEthStatsEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.1 | ColumncaUcsBladeIfEthStatsUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.2 | ColumncaUcsBladeIfEthStatsBladeIndex | read-only | current | Index of the blade from the caBladeTable. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.3 | ColumncaUcsBladeIfEthStatsIfIndex | read-only | current | Index of an interface on a blade; corresponds to caBladeIfIndex. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.4 | ColumncaUcsBladeIfEthStatsTxGreaterThanOrEqualTo9216 | read-only | current | Count of transmitted packets with length greater than or equal to 9216 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.5 | ColumncaUcsBladeIfEthStatsRxGreaterThanOrEqualTo9216 | read-only | current | Count of received packets with length greater than or equal to 9216 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.6 | ColumncaUcsBladeIfEthStatsTxLessThan2048 | read-only | current | Count of transmitted packets with length greater than 1518 bytes and less than 2048. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.7 | ColumncaUcsBladeIfEthStatsRxLessThan2048 | read-only | current | Count of received packets with length greater than 1518 bytes and less than 2048. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.8 | ColumncaUcsBladeIfEthStatsTxLessThan4096 | read-only | current | Count of transmitted packets with length greater than 2048 bytes and less than 4096 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.9 | ColumncaUcsBladeIfEthStatsRxLessThan4096 | read-only | current | Count of received packets with length greater than 2048 bytes nd less than 4096 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.10 | ColumncaUcsBladeIfEthStatsTxLessThan8192 | read-only | current | Count of transmitted packets with length greater than 4096 bytes and less tahn 8192 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.11 | ColumncaUcsBladeIfEthStatsRxLessThan8192 | read-only | current | Count of received packets with length greater than 4096 bytes and less tahn 8192 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.12 | ColumncaUcsBladeIfEthStatsTxLessThan9216 | read-only | current | Count of transmitted packets with length greater than 8192 bytes and less than 9216 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.13 | ColumncaUcsBladeIfEthStatsRxLessThan9216 | read-only | current | Count of received packets with length greater than 8192 bytes and less than 9216 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.14 | ColumncaUcsBladeIfEthStatsTxLessThanOrEqualTo1518 | read-only | current | Count of transmitted packets with length greater than or equal to 1518 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.15 | ColumncaUcsBladeIfEthStatsRxLessThanOrEqualTo1518 | read-only | current | Count of received packets with length greater than or equal to 1518 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.16 | ColumncaUcsBladeIfEthStatsTxEquals64 | read-only | current | Count of transmitted packets with length equal to 64 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.17 | ColumncaUcsBladeIfEthStatsRxEquals64 | read-only | current | Count of received packets with length equal to 64 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.18 | ColumncaUcsBladeIfEthStatsTxLessThan1024 | read-only | current | Count of transmitted packets with length greater than or equal to 512 bytes and less than 1024 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.19 | ColumncaUcsBladeIfEthStatsRxLessThan1024 | read-only | current | Count of received packets with length greater than or equal to 512 bytes and less than 1024 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.20 | ColumncaUcsBladeIfEthStatsTxLessThan128 | read-only | current | Count of transmitted packets with length greater than 64 bytes and less than 128 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.21 | ColumncaUcsBladeIfEthStatsRxLessThan128 | read-only | current | Count of received packets with length greater than 64 bytes and less than 128 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.22 | ColumncaUcsBladeIfEthStatsTxLessThan256 | read-only | current | Count of transmitted packets with length greater than or equal to 128 bytes and less than 256 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.23 | ColumncaUcsBladeIfEthStatsRxLessThan256 | read-only | current | Count of received packets with length greater than or equal to 128 bytes and less than 256 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.24 | ColumncaUcsBladeIfEthStatsTxLessThan512 | read-only | current | Count of transmitted packets with length greater than or equal to 256 bytes and less than 512 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.25 | ColumncaUcsBladeIfEthStatsRxLessThan512 | read-only | current | Count of received packets with length greater than or equal to 256 bytes and less than 512 bytes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.26 | ColumncaUcsBladeIfEthStatsTxBadCrcPackets | read-only | current | Count of transmitted packets which failed their CRC. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.27 | ColumncaUcsBladeIfEthStatsRxBadCrcPackets | read-only | current | Count of received packets which failed their CRC. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.28 | ColumncaUcsBladeIfEthStatsTxBadLengthPackets | read-only | current | Count of transmitted packets with incorrect length values. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.29 | ColumncaUcsBladeIfEthStatsRxBadLengthPackets | read-only | current | Count of received packets with incorrect length values. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.30 | ColumncaUcsBladeIfEthStatsTxOversizedBadCrcPackets | read-only | current | Count of transmitted oversized packets which failed their CRC. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.31 | ColumncaUcsBladeIfEthStatsRxOversizedBadCrcPackets | read-only | current | Count of received oversized packets which failed their CRC. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.32 | ColumncaUcsBladeIfEthStatsTxOversizedGoodCrcPackets | read-only | current | Count of transmitted oversized packets with correct CRCs. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.33 | ColumncaUcsBladeIfEthStatsRxOversizedGoodCrcPackets | read-only | current | Count of received oversized packets with correct CRCs. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.34 | ColumncaUcsBladeIfEthStatsTxOversizedPackets | read-only | current | Count of transmitted oversize packets. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.35 | ColumncaUcsBladeIfEthStatsRxOversizedPackets | read-only | current | Count of received oversize packets. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.36 | ColumncaUcsBladeIfEthStatsTxUndersizedBadCrcPackets | read-only | current | Count of transmitted undersized packets which failed their CRC. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.37 | ColumncaUcsBladeIfEthStatsRxUndersizedBadCrcPackets | read-only | current | Count of received undersized packets which failed their CRC. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.38 | ColumncaUcsBladeIfEthStatsTxUndersizedGoodCrcPackets | read-only | current | Count of transmitted undersized packets with correct CRCs. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.39 | ColumncaUcsBladeIfEthStatsRxUndersizedGoodCrcPackets | read-only | current | Count of received undersized packets with correct CRCs. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.40 | ColumncaUcsBladeIfEthStatsTxGoodPackets | read-only | current | Count of transmitted good packets. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.41 | ColumncaUcsBladeIfEthStatsRxGoodPackets | read-only | current | Count of received good packets. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.42 | ColumncaUcsBladeIfEthStatsTxPausePackets | read-only | current | Count of transmitted pause packets. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.43 | ColumncaUcsBladeIfEthStatsRxPausePackets | read-only | current | Count of received pause packets. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.44 | ColumncaUcsBladeIfEthStatsTxPerPriorityPausePackets | read-only | current | Count of pause packets transmitted per priority. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.45 | ColumncaUcsBladeIfEthStatsRxPerPriorityPausePackets | read-only | current | Count of pause packets received per priority. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.46 | ColumncaUcsBladeIfEthStatsTxPppPackets | read-only | current | Count of transmitted PPP packets. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.47 | ColumncaUcsBladeIfEthStatsRxPppPackets | read-only | current | Count of received PPP packets. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.48 | ColumncaUcsBladeIfEthStatsTxTotalPackets | read-only | current | Count of transmitted packets. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.49 | ColumncaUcsBladeIfEthStatsRxTotalPackets | read-only | current | Count of transmitted packets. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.50 | ColumncaUcsBladeIfEthStatsTxVlanPackets | read-only | current | Count of transmitted VLAN packets. |
| 1.3.6.1.4.1.546.16.58.3.2.2.2.1.51 | ColumncaUcsBladeIfEthStatsRxVlanPackets | read-only | current | Count of received VLAN packets. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3 | TablecaUcsBladeIfFcStatsTable | not-accessible | current | caUcsBladeIfFcStats table. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1 | RowcaUcsBladeIfFcStatsEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.1 | ColumncaUcsBladeIfFcStatsUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.2 | ColumncaUcsBladeIfFcStatsBladeIndex | read-only | current | Index of the blade from the caBladeTable. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.3 | ColumncaUcsBladeIfFcStatsIfIndex | read-only | current | Index of an interface on a blade; corresponds to caBladeIfIndex. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.4 | ColumncaUcsBladeIfFcStatsInvalidCRCCount | read-only | current | Number of frames received with invalid CRC. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.5 | ColumncaUcsBladeIfFcStatsLinkFailureCount | read-only | current | Number of times a link error has occurred. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.6 | ColumncaUcsBladeIfFcStatsLipCount | read-only | current | Number of LIP events that have occurred on an arbitrated loop. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.7 | ColumncaUcsBladeIfFcStatsLossOfSignalCount | read-only | current | Number of times loss of signal has occurred. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.8 | ColumncaUcsBladeIfFcStatsLossOfSyncCount | read-only | current | Number of times loss of sync has occurred. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.9 | ColumncaUcsBladeIfFcStatsNOSCount | read-only | current | Number of NOS events that have occurred on the switched Fabric. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.10 | ColumncaUcsBladeIfFcStatsControlRequests | read-only | current | Number of FC-4 operations which are not intended to cause FC-4 data movement. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.11 | ColumncaUcsBladeIfFcStatsInputMegabytes | read-only | current | Number of megabytes of FC-4 data input. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.12 | ColumncaUcsBladeIfFcStatsInputRequests | read-only | current | Number of FC-4 operations causing FC-4 data input. Some single FC-4 re-quests may cause both input and output of data (e.g., Bidirectional SCSI commands in FCP… |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.13 | ColumncaUcsBladeIfFcStatsOutputMegabytes | read-only | current | Number of megabytes of FC-4 data output. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.14 | ColumncaUcsBladeIfFcStatsOutputRequests | read-only | current | Number of FC-4 operations causing FC-4 data output. Some single FC-4 re-quests may cause both input and output of data (e.g., Bidirectional SCSI commands in FC… |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.15 | ColumncaUcsBladeIfFcStatsDumpedFrames | read-only | current | Number of frames that were lost due to a lack of host buffers available. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.16 | ColumncaUcsBladeIfFcStatsErrorFrames | read-only | current | Number of frames that have been received in error. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.17 | ColumncaUcsBladeIfFcStatsRxFrames | read-only | current | Number of total Received Fibre Channel frames across all protocols and classes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.18 | ColumncaUcsBladeIfFcStatsTxFrames | read-only | current | Number of total Transmitted Fibre Channel frames across all protocols and classes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.19 | ColumncaUcsBladeIfFcStatsRxBadFrames | read-only | current | Number of invalid received Fibre Channel frames. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.20 | ColumncaUcsBladeIfFcStatsTotalRxFrames | read-only | current | Number of total received Fibre Channel frames accross all protocols and classes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.21 | ColumncaUcsBladeIfFcStatsTxBadFrames | read-only | current | Number of invalid transmitted Fibre Channel frames. |
| 1.3.6.1.4.1.546.16.58.3.2.2.3.1.22 | ColumncaUcsBladeIfFcStatsTotalTxFrames | read-only | current | Number of total transmitted Fibre Channel frames across all protocols and classes. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4 | TablecaUcsMenloStatsTable | not-accessible | current | caUcsMenloStats table. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1 | RowcaUcsMenloStatsEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.1 | ColumncaUcsMenloStatsUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.2 | ColumncaUcsMenloStatsBladeIndex | read-only | current | Index of the blade for the caBladeTable. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.3 | ColumncaUcsMenloStatsIndex | read-only | current | Index of a Menlo instance on a blade. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.4 | ColumncaUcsMenloStatsCorrectableErrors | read-only | current | Count of the number of packets that have correctable errors. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.5 | ColumncaUcsMenloStatsUncorrectableErrors | read-only | current | Count of the number of packets that have errors which could not be corrected. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.6 | ColumncaUcsMenloStatsDceRxPauseCFC | read-only | current | Count of the number of received 802.3x PAUSE packets for congestion flow control on the Data Center Ethernet. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.7 | ColumncaUcsMenloStatsDceRxPausePFC | read-only | current | Count of the number of received 802.3x PAUSE packets for priority flow control on the Data Center Ethernet. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.8 | ColumncaUcsMenloStatsDceTxPauseCFC | read-only | current | Count of the number of transmitted 802.3x PAUSE packets for congestion flow control on the Data Center Ethernet. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.9 | ColumncaUcsMenloStatsDceTxPausePFC | read-only | current | Count of the number of transmitted 802.3x PAUSE packets for priority flow control on the Data Center Ethernet. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.10 | ColumncaUcsMenloStatsEthCorrectableErrors | read-only | current | Count of the number of Ethernet packets that have correctable errors. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.11 | ColumncaUcsMenloStatsEthDropAcl | read-only | current | Count of the number of Ethernet packets dropped due to an access control list check. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.12 | ColumncaUcsMenloStatsEthPopErrors | read-only | current | Count of the number of Ethernet packets resulting in an error when popping them from a queue. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.13 | ColumncaUcsMenloStatsEthPushErrors | read-only | current | Count of the number of Ethernet packets resulting in an error when pushing them onto a queue. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.14 | ColumncaUcsMenloStatsEthUncorrectableErrors | read-only | current | Count of the number of Ethernet packets that have errors which could not be corrected. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.15 | ColumncaUcsMenloStatsEthDropOverrun | read-only | current | Count of the number of Ethernet packets dropped due to a buffer overrun. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.16 | ColumncaUcsMenloStatsEthDropRunt | read-only | current | Count of the number of Ethernet packets dropped due to being shorter than 64 bytes but having a valid CRC. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.17 | ColumncaUcsMenloStatsEthTruncateOverrun | read-only | current | Count of the number of Ethernet packets carrying truncated Fibre Channel packets that caused a buffer overrun. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.18 | ColumncaUcsMenloStatsFcCorrectableErrors | read-only | current | Count of the number of Fibre Channel packets that have correctable errors. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.19 | ColumncaUcsMenloStatsFcPopErrors | read-only | current | Count of the number of Fiber Channel packets that caused an error when being popped from a queue. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.20 | ColumncaUcsMenloStatsFcPushErrors | read-only | current | Count of the number of Fibre Channel packets that caused an error when being pushed onto a queue. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.21 | ColumncaUcsMenloStatsFcUncorrectableErrors | read-only | current | Count of the number of Fibre Channel packets that have uncorrectable errors. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.22 | ColumncaUcsMenloStatsHostRxPauseCFC | read-only | current | Count of the number of received 802.3x PAUSE packets for congestion flow control on the Host ports. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.23 | ColumncaUcsMenloStatsHostRxPausePFC | read-only | current | Count of the number of received 802.3x PAUSE packets for priority flow control on the Host ports. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.24 | ColumncaUcsMenloStatsHostTxPauseCFC | read-only | current | Count of the number of transmitted 802.3x PAUSE packets for congestion flow control on the Host ports. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.25 | ColumncaUcsMenloStatsHostTxPausePFC | read-only | current | Count of the number of transmitted 802.3x PAUSE packets for priority flow control on the Host ports. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.26 | ColumncaUcsMenloStatsMcpuCorrectableErrors | read-only | current | Count of the number of correctable errors detected by the Menlo master central processing unit. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.27 | ColumncaUcsMenloStatsMcpuPopErrors | read-only | current | Count of the number of errors by the Menlo master central processing unit while popping packets from a queue. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.28 | ColumncaUcsMenloStatsMcpuPushErrors | read-only | current | Count of the number of errors by the Menlo master central processing unit while pushing packets on a queue. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.29 | ColumncaUcsMenloStatsMcpuUncorrectableErrors | read-only | current | Count of the number of uncorrectable errors detected by the Menlo master central processing unit. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.30 | ColumncaUcsMenloStatsMcpuDropAcl | read-only | current | Count of the number of packets dropped due to a check against an access control list by the Menlo master central processing unit. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.31 | ColumncaUcsMenloStatsMcpuDropOverrun | read-only | current | Count of the number of packets dropped due to a buffer overrun by the Menlo master central processing unit. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.32 | ColumncaUcsMenloStatsMcpuDropRunt | read-only | current | Count of the number of packets dropped due to an undersized packet with a correct CRC by the Menlo master central processing unit. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.33 | ColumncaUcsMenloStatsMcpuTruncateOverrun | read-only | current | Count of the number of Ethernet packets carrying truncated Fibre Channel packets that caused a buffer overrun by the master central processing unit. |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.34 | ColumncaUcsMenloStatsNetEgDropCmd | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.35 | ColumncaUcsMenloStatsNetEgDropLifCfgInvalid | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.36 | ColumncaUcsMenloStatsNetEgDropLifMapNoHit | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.37 | ColumncaUcsMenloStatsNetEgDropSrcBind | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.38 | ColumncaUcsMenloStatsNetEgLearnReqDrop | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.39 | ColumncaUcsMenloStatsNetInDropFcLifInvalid | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.40 | ColumncaUcsMenloStatsNetInDropFcMulticast | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.41 | ColumncaUcsMenloStatsNetInDropNullPif | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.4.1.42 | ColumncaUcsMenloStatsNetInFwdLookupNoHit | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.5 | TablecaUcsMenloQStatsTable | not-accessible | current | caUcsMenloQStats table. |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1 | RowcaUcsMenloQStatsEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.1 | ColumncaUcsMenloQStatsUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.2 | ColumncaUcsMenloQStatsBladeIndex | read-only | current | Index of the blade for the caBladeTable. |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.3 | ColumncaUcsMenloQStatsIndex | read-only | current | Index of a Menlo instance on a blade; same as caUcsMenloStatsIndex. |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.4 | ColumncaUcsMenloQStatsComponentIndex | read-only | current | Index of a Menlo component on a blade. |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.5 | ColumncaUcsMenloQStatsComponentId | read-only | current | The type of Menlo compoennt to which the statistics of this instance apply. |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.6 | ColumncaUcsMenloQStatsCorrectableErrors | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.7 | ColumncaUcsMenloQStatsPopErrors | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.8 | ColumncaUcsMenloQStatsPushErrors | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.9 | ColumncaUcsMenloQStatsUncorrectableErrors | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.10 | ColumncaUcsMenloQStatsDropOverrunN0 | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.11 | ColumncaUcsMenloQStatsDropOverrunN1 | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.12 | ColumncaUcsMenloQStatsTruncateOverrunN0 | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.5.1.13 | ColumncaUcsMenloQStatsTruncateOverrunN1 | read-only | current | blank |
| 1.3.6.1.4.1.546.16.58.3.2.2.6 | TablecaUcsMezzanineTable | not-accessible | current | caUcsMezzanine table. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1 | RowcaUcsMezzanineEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.1 | ColumncaUcsMezzanineUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.2 | ColumncaUcsMezzanineBladeIndex | read-only | current | Index of the blade for the caBladeTable. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.3 | ColumncaUcsMezzanineIndex | read-only | current | Index of a mezzanine card relative to the blade. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.4 | ColumncaUcsMezzanineModel | read-only | current | Model of the mezzanine card. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.5 | ColumncaUcsMezzanineSerialNumber | read-only | current | Serial number of the mezzanine card. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.6 | ColumncaUcsMezzanineVendor | read-only | current | Vendor of the mezzanine card. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.7 | ColumncaUcsMezzanineRevision | read-only | current | Revision of the model of the mezzanine card. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.8 | ColumncaUcsMezzanineCondition | read-only | current | Overall status of the mezzanine card. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.9 | ColumncaUcsMezzanineBootLoaderVersion | read-only | current | Version of the boot loadeer firmware that is running currently. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.10 | ColumncaUcsMezzanineFirmwareVersion | read-only | current | Version of the firmware that is currently running. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.11 | ColumncaUcsMezzanineStartupFirmwareVersion | read-only | current | Startup version of the firmware. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.12 | ColumncaUcsMezzanineBackupFirmwareVersion | read-only | current | Backup version of the firmware. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.13 | ColumncaUcsMezzanineProductName | read-only | current | product name of the firmware. |
| 1.3.6.1.4.1.546.16.58.3.2.2.6.1.14 | ColumncaUcsMezzaninePid | read-only | current | Pid of the firmware. |
| 1.3.6.1.4.1.546.16.58.3.2.3 | NodecaUcsBladeServer | |||
| 1.3.6.1.4.1.546.16.58.3.2.3.1 | NodecaUcsBladeServerCpu | |||
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1 | TablecaUcsCpuTable | not-accessible | current | UCS Cpu table. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1 | RowcaUcsCpuEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.1 | ColumncaUcsCpuUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.2 | ColumncaUcsCpuBladeIndex | read-only | current | Corresponds to caBladeIndes. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.3 | ColumncaUcsCpuIndex | read-only | current | Instance of a CPU on the motherboard of this blade. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.4 | ColumncaUcsCpuModel | read-only | current | Model of the CPU. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.5 | ColumncaUcsCpuSerialNumber | read-only | current | Serial Number of the CPU. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.6 | ColumncaUcsCpuVendor | read-only | current | Vendor of the CPU. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.7 | ColumncaUcsCpuRevision | read-only | current | Revision of the model of the CPU. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.8 | ColumncaUcsCpuTemp | read-only | current | Currently available temperature readings from the CPU temp sensor. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.9 | ColumncaUcsCpuArchitecture | read-only | current | Processor architecture of this CPU, for example 'Xeon'. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.10 | ColumncaUcsCpuCores | read-only | current | Number of cores in the CPU. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.11 | ColumncaUcsCpuSocketDesignation | read-only | current | Identifier of the socket this CPU is inserted into. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.12 | ColumncaUcsCpuSpeed | read-only | current | Effective clock speed of the CPU in MHz. |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.13 | ColumncaUcsCpuStepping | read-only | current | CPU silicon revision (AMD calls it a revision as well; Intel calls it stepping information). |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.14 | ColumncaUcsCpuThread | read-only | current | CPU threads |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.15 | ColumncaUcsCpuProductName | read-only | current | Product name of CPU |
| 1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.16 | ColumncaUcsCpuPid | read-only | current | Pid of CPU |
| 1.3.6.1.4.1.546.16.58.3.2.3.2 | NodecaUcsBladeServerMotherboard | |||
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1 | TablecaUcsMotherboardTable | not-accessible | current | caUcsBladeServerMotherboard table. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1 | RowcaUcsBladeServerMotherboardEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.1 | ColumncaUcsMotherboardUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.2 | ColumncaUcsMotherboardBladeIndex | read-only | current | Index of the blade for the caBladeTable. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.3 | ColumncaUcsMotherboardModel | read-only | current | Model of the motherboard. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.4 | ColumncaUcsMotherboardSerialNumber | read-only | current | Serial number of the motherboard. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.5 | ColumncaUcsMotherboardVendor | read-only | current | Vendor of the motherboard. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.6 | ColumncaUcsMotherboardRevision | read-only | current | Revision of the model of the motherboard. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.7 | ColumncaUcsMotherboardloSensorTemp | read-only | current | Degrees celsius. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.8 | ColumncaUcsMotherboardRearSensorTemp | read-only | current | Degrees celsius. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.9 | ColumncaUcsMotherboardConsumedPower | read-only | current | Wattage being currently consumed by the motherboard. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.10 | ColumncaUcsMotherboard12vCurrent | read-only | current | Amperage on the 12 volt motherboard input. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.11 | ColumncaUcsMotherboard12vVoltage | read-only | current | Voltage on the 12 volt motherboard input. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.12 | ColumncaUcsMotherboardDdr3Line0Voltage | read-only | current | Voltage to the memory banks in line 0. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.13 | ColumncaUcsMotherboardDdr3Line1Voltage | read-only | current | Voltage to the memory banks in line 1. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.14 | ColumncaUcsMotherboardCpu0Voltage | read-only | current | Voltage to the CPU in CPU slot 0. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.15 | ColumncaUcsMotherboardCpu1Voltage | read-only | current | Voltage to the CPU in CPU slot 1. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.16 | ColumncaUcsMotherboardProductName | read-only | current | Product name of the motherboard. |
| 1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.17 | ColumncaUcsMotherboardPid | read-only | current | Pid of the motherboard. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3 | NodecaUcsBladeServerMemory | |||
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1 | TablecaUcsMemoryArrayTable | not-accessible | current | UCS Memory Array table. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1 | RowcaUcsMemoryArrayEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.1 | ColumncaUcsMemoryArrayUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.2 | ColumncaUcsMemoryArrayBladeIndex | read-only | current | Corresponds to caBladeIndes. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.3 | ColumncaUcsMemoryArrayIndex | read-only | current | Instance of a memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.4 | ColumncaUcsMemoryArrayModel | read-only | current | Model of a memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.5 | ColumncaUcsMemoryArraySerialNumber | read-only | current | Serial number of the memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.6 | ColumncaUcsMemoryArrayVendor | read-only | current | Vendor of the memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.7 | ColumncaUcsMemoryArrayRevision | read-only | current | Revision of the model of the memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.8 | ColumncaUcsMemoryArrayMaxCapacity | read-only | current | Total MBs if all possible memory usable on this memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.9 | ColumncaUcsMemoryArrayMaxNumOfDimms | read-only | current | Maximum number of memory DIMMs on this memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.10 | ColumncaUcsMemoryArrayCpuId | read-only | current | CPU instance (on this blade) associated with this memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.11 | ColumncaUcsMemoryArrayNumOfDimms | read-only | current | Current number of installed DIMMs in the memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.12 | ColumncaUcsMemoryArrayCurrentCapacity | read-only | current | Total MBs of memory currently installed in the memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.13 | ColumncaUcsMemoryArrayErrorCorrection | read-only | current | The type of error correction required by the memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.14 | ColumncaUcsMemoryArrayProductName | read-only | current | Product name of the model of the memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.15 | ColumncaUcsMemoryArrayPid | read-only | current | Pid of the model of the memory array. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2 | TablecaUcsMemoryModuleTable | not-accessible | current | UCS Memory Array table. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1 | RowcaUcsMemoryModuleEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.1 | ColumncaUcsMemoryModuleUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.2 | ColumncaUcsMemoryModuleBladeIndex | read-only | current | Corresponds to caBladeIndex. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.3 | ColumncaUcsMemoryModuleIndex | read-only | current | Instance of a memory module. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.4 | ColumncaUcsMemoryModuleModel | read-only | current | The model of the memory module. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.5 | ColumncaUcsMemoryModuleSerialNumber | read-only | current | The serial number of the memory module. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.6 | ColumncaUcsMemoryModuleVendor | read-only | current | Vendor of the memory module. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.7 | ColumncaUcsMemoryModuleRevision | read-only | current | Revision of the model of the memory module. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.8 | ColumncaUcsMemoryModuleType | read-only | current | The form and specification adherence of the memory interface. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.9 | ColumncaUcsMemoryModuleLatency | read-only | current | Number of clock cycles (synchronous DRAM) for the data to be available at a particular memory address. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.10 | ColumncaUcsMemoryModuleFormFactor | read-only | current | The type of memory (DIMM, SODIMM, etc.) |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.11 | ColumncaUcsMemoryModuleSpeed | read-only | current | The speed of the module. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.12 | ColumncaUcsMemoryModuleLocation | read-only | current | Which DIMM slot this memory is inserted into. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.13 | ColumncaUcsMemoryModuleWidth | read-only | current | The number of bits in a bank of memory. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.14 | ColumncaUcsMemoryModuleBank | read-only | current | The number of banks in this memory module. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.15 | ColumncaUcsMemoryModuleClock | read-only | current | MHz |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.16 | ColumncaUcsMemoryModuleTemp | read-only | current | degrees celsius |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.17 | ColumncaUcsMemoryModuleMemoryArrayIndex | read-only | current | Corresponds to caMemoryArrayIndex; indicates to which memory array this memory unit belongs. |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.18 | ColumncaUcsMemoryModuleCapacity | read-only | current | size of the memory module in MBs |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.19 | ColumncaUcsMemoryModulePresence | read-only | current | Presence of DIMM |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.20 | ColumncaUcsMemoryModuleProductName | read-only | current | Product name of DIMM |
| 1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.21 | ColumncaUcsMemoryModulePid | read-only | current | Pid of DIMM |
| 1.3.6.1.4.1.546.16.58.3.2.3.4 | NodecaUcsBladeServerStorage | |||
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1 | TablecaUcsStorageTable | not-accessible | current | caUcsBladeServerStorageController table. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1 | RowcaUcsStorageEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.1 | ColumncaUcsStorageUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.2 | ColumncaUcsStorageBladeIndex | read-only | current | Corresponds to caBladeIndex. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.3 | ColumncaUcsStorageControllerIndex | read-only | current | Index of a storage controller on this blade. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.4 | ColumncaUcsStorageControllerModel | read-only | current | Model of the storage controller. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.5 | ColumncaUcsStorageControllerSerialNumber | read-only | current | Serial number of the storage controller. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.6 | ColumncaUcsStorageControllerVendor | read-only | current | Vendor of the storage controller. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.7 | ColumncaUcsStorageControllerRevision | read-only | current | Revision of the model of the storage controller. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.8 | ColumncaUcsStorageControllerType | read-only | current | Type of storage controller - only currently available value is 'SAS(1)'. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.9 | ColumncaUcsStorageControllerBootLoaderVersion | read-only | current | Version of the boot loader firmware that is running currently. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.10 | ColumncaUcsStorageControllerFirmwareVersion | read-only | current | Version of the storage controller firmware that is currently running. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.11 | ColumncaUcsStorageControllerStartupFirmwareVersion | read-only | current | Startup version fo the storage controller firmware. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.12 | ColumncaUcsStorageControllerProductName | read-only | current | Product name of the storage controller. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.13 | ColumncaUcsStorageControllerPid | read-only | current | Pid of the storage controller. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2 | TablecaUcsStorageLocalDiskTable | not-accessible | current | caUcsStorageLocalDisk table. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1 | RowcaUcsStorageLocalDiskEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.1 | ColumncaUcsStorageLocalDiskUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.2 | ColumncaUcsStorageLocalDiskBladeIndex | read-only | current | Corresponds to caBladeIndex. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.3 | ColumncaUcsStorageLocalDiskIndex | read-only | current | Index of a local disk drive on this blade. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.4 | ColumncaUcsStorageLocalDiskModel | read-only | current | Model of the disk drive. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.5 | ColumncaUcsStorageLocalDiskSerialNumber | read-only | current | Serial number of the disk drive. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.6 | ColumncaUcsStorageLocalDiskVendor | read-only | current | Vendor of the disk drive. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.7 | ColumncaUcsStorageLocalDiskRevision | read-only | current | Revision of the model of the disk drive. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.8 | ColumncaUcsStorageLocalDiskNumBlocks | read-only | current | Total number of blocks on this drive. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.9 | ColumncaUcsStorageLocalDiskSize | read-only | current | Size in MBs of a block on this drive. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.10 | ColumncaUcsStorageLocalDiskBlockSize | read-only | current | Size in bytes of a block on this drive. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.11 | ColumncaUcsStorageLocalDiskFirmwareVersion | read-only | current | Version of the firmware that is currently running. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.12 | ColumncaUcsStorageLocalDiskControllerIndex | read-only | current | Corresponds to caStorageControllerIndex. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.13 | ColumncaUcsStorageLocalDiskProductName | read-only | current | Product name of the disk drive. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.14 | ColumncaUcsStorageLocalDiskPid | read-only | current | Pid of the disk drive. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3 | TablecaUcsStorageLocalLunTable | not-accessible | current | caUcsStorageLocalLun table. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1 | RowcaUcsStorageLocalLunEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.1 | ColumncaUcsStorageLocalLunUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.2 | ColumncaUcsStorageLocalLunBladeIndex | read-only | current | Corresponds to caBladeIndex. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.3 | ColumncaUcsStorageLocalLunIndex | read-only | current | Instance of a logical unit number (LUN) designation configured on the blade. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.4 | ColumncaUcsStorageLocalLunModel | read-only | current | Model of the storage controller implementing this LUN. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.5 | ColumncaUcsStorageLocalLunSerialNumber | read-only | current | Serial number of the storage controller implementing this LUN. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.6 | ColumncaUcsStorageLocalLunVendor | read-only | current | Vendor of the storage controller implementing this LUN. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.7 | ColumncaUcsStorageLocalLunRevision | read-only | current | Revision of the model of the storage controller implementing this LUN. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.8 | ColumncaUcsStorageLocalLunId | read-only | current | Logical identifier and numberical designation of this LUN. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.9 | ColumncaUcsStorageLocalLunNumBlocks | read-only | current | Total number of blocks in this partition addressed by this LUN.. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.10 | ColumncaUcsStorageLocalLunSize | read-only | current | Number of MBs in the partition addressed by this LUN. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.11 | ColumncaUcsStorageLocalLunBlockSize | read-only | current | Size in bytes of a block in the partition addressed by this LUN. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.12 | ColumncaUcsStorageLocalLunType | read-only | current | Underlying format of the disk resource supplying this LUN. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.13 | ColumncaUcsStorageLocalLunControllerIndex | read-only | current | Corresponds to caStorageControllerIndex. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.14 | ColumncaUcsStorageLocalLunProductName | read-only | current | Product name of the storage controller implementing this LUN. |
| 1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.15 | ColumncaUcsStorageLocalLunPid | read-only | current | Pid of the storage controller implementing this LUN. |
| 1.3.6.1.4.1.546.16.58.3.3 | NodecaUcsSwitchExt | |||
| 1.3.6.1.4.1.546.16.58.3.3.1 | NodecaUcsSwitch | |||
| 1.3.6.1.4.1.546.16.58.3.3.1.1 | TablecaUcsSwitchTable | not-accessible | current | UcsSwitch table. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1 | RowcaUcsSwitchEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.1 | ColumncaUcsSwitchUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.2 | ColumncaUcsSwitchIndex | read-only | current | Same as caSwitchIndex. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.3 | ColumncaUcsSwitchInbandIfIpType | read-only | current | In-band management IP Address Type. This is an enumerated INTEGER of type InetAddressType and applies to the In-band IP, Mask, and Gateway addresses. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.4 | ColumncaUcsSwitchInbandIfIp | read-only | current | In-band management IP Address. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.5 | ColumncaUcsSwitchInbandIfMask | read-only | current | In-band management IP Address mask. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.6 | ColumncaUcsSwitchInbandIfGateway | read-only | current | In-band management gateway address for IP traffic. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.7 | ColumncaUcsSwitchInbandIfVnet | read-only | current | In-band management VLAN id. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.8 | ColumncaUcsSwitchOutOfBandIfIpType | read-only | current | Out-of-band management IP Address Type. This is an enumerated INTEGER of type InetAddressType and applies to the Out-of-band IP, Mask, and Gateway addresses. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.9 | ColumncaUcsSwitchOutOfBandIfIp | read-only | current | Out-of-band management IP address. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.10 | ColumncaUcsSwitchOutOfBandIfMask | read-only | current | Out-of-band management IP address mask. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.11 | ColumncaUcsSwitchOutOfBandIfGateway | read-only | current | Out-of-band management gateway address for IP traffic. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.12 | ColumncaUcsSwitchAdminInbandIfState | read-only | current | Determining whether administrative communication to the switch can occur in-band. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.13 | ColumncaUcsSwitchEnvFanControllerInlet1 | read-only | current | Temperature in degrees celsius. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.14 | ColumncaUcsSwitchEnvFanControllerInlet2 | read-only | current | Temperature in degrees celsius. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.15 | ColumncaUcsSwitchEnvFanControllerInlet3 | read-only | current | Temperature in degrees celsius. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.16 | ColumncaUcsSwitchEnvFanControllerInlet4 | read-only | current | Temperature in degrees celsius. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.17 | ColumncaUcsSwitchEnvMainBoardOutlet1 | read-only | current | Temperature in degrees celsius. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.18 | ColumncaUcsSwitchEnvMainBoardOutlet2 | read-only | current | Temperature in degrees celsius. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.19 | ColumncaUcsSwitchEnvMezzBoardOutlet1 | read-only | current | Temperature in degrees celsius. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.20 | ColumncaUcsSwitchEnvMezzBoardOutlet2 | read-only | current | Temperature in degrees celsius. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.21 | ColumncaUcsSwitchCpuLoad | read-only | current | CPU utilization over the last minute. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.22 | ColumncaUcsSwitchAvailableMemory | read-only | current | Available memory on the switch in MBs. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.23 | ColumncaUcsSwitchMemoryCacheSize | read-only | current | Size of the memory cache on the switch in MBs. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.24 | ColumncaUcsSwitchBootLoaderVersion | read-only | current | Version of the boot loader firmware that is running currently. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.25 | ColumncaUcsSwitchKernelVersion | read-only | current | Version of the kernel firmware that is currently running. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.26 | ColumncaUcsSwitchSystemVersion | read-only | current | Version of the system firmware taht is currently running. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.27 | ColumncaUcsSwitchStartupKernelVersion | read-only | current | Startup version of the kernel firmware. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.28 | ColumncaUcsSwitchStartupSystemVersion | read-only | current | Startup version of the system firmware. |
| 1.3.6.1.4.1.546.16.58.3.3.1.1.1.29 | ColumncaUcsSwitchOperability | read-only | current | Operability of the switch. |
| 1.3.6.1.4.1.546.16.58.3.3.1.2 | ScalarcaUcsSwitchTableLastChange | read-only | current | Last table refresh time |
| 1.3.6.1.4.1.546.16.58.3.3.2 | NodecaUcsSwitchFan | |||
| 1.3.6.1.4.1.546.16.58.3.3.2.1 | TablecaUcsSwitchFanTable | not-accessible | current | caUcsSwitchFan table. |
| 1.3.6.1.4.1.546.16.58.3.3.2.1.1 | RowcaUcsSwitchFanEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.3.2.1.1.1 | ColumncaUcsSwitchFanUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.3.2.1.1.2 | ColumncaUcsSwitchFanSwitchId | read-only | current | Same as caSwitchIndex. |
| 1.3.6.1.4.1.546.16.58.3.3.2.1.1.3 | ColumncaUcsSwitchFanId | read-only | current | Id unique within the context of the switch; same as caSwitchFanIndex. |
| 1.3.6.1.4.1.546.16.58.3.3.2.1.1.4 | ColumncaUcsSwitchFanOperState | read-only | current | Operational state of the switch fan. |
| 1.3.6.1.4.1.546.16.58.3.3.2.1.1.5 | ColumncaUcsSwitchFanOperability | read-only | current | Operability of the switch fan. |
| 1.3.6.1.4.1.546.16.58.3.3.2.1.1.6 | ColumncaUcsSwitchFanPerformance | read-only | current | Switch fan performance |
| 1.3.6.1.4.1.546.16.58.3.3.2.1.1.7 | ColumncaUcsSwitchFanPower | read-only | current | Switch fan power status |
| 1.3.6.1.4.1.546.16.58.3.3.3 | NodecaUcsSwitchPower | |||
| 1.3.6.1.4.1.546.16.58.3.3.3.1 | TablecaUcsSwitchPsuTable | not-accessible | current | caUcsSwitchPsu table. |
| 1.3.6.1.4.1.546.16.58.3.3.3.1.1 | RowcaUcsSwitchPsuEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.3.3.1.1.1 | ColumncaUcsSwitchPsuUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.3.3.1.1.2 | ColumncaUcsSwitchPsuSwitchId | read-only | current | Same as caSwitchIndex. |
| 1.3.6.1.4.1.546.16.58.3.3.3.1.1.3 | ColumncaUcsSwitchPsuId | read-only | current | Id unique within the context of the switch; same as caSwitchPsuIndex. |
| 1.3.6.1.4.1.546.16.58.3.3.3.1.1.4 | ColumncaUcsSwitchPsuOperState | read-only | current | Operational state of the switch power supply unit. |
| 1.3.6.1.4.1.546.16.58.3.3.3.1.1.5 | ColumncaUcsSwitchPsuOperability | read-only | current | Operability of the switch power supply unit. |
| 1.3.6.1.4.1.546.16.58.3.3.3.1.1.6 | ColumncaUcsSwitchPsuPerformance | read-only | current | Switch Psu performance |
| 1.3.6.1.4.1.546.16.58.3.3.3.1.1.7 | ColumncaUcsSwitchPsuPower | read-only | current | Switch Psu power status |
| 1.3.6.1.4.1.546.16.58.3.3.4 | NodecaUcsSwitchInterfaces | |||
| 1.3.6.1.4.1.546.16.58.3.3.4.1 | TablecaUcsSwitchConnTable | not-accessible | current | caUcsSwitchConn table. |
| 1.3.6.1.4.1.546.16.58.3.3.4.1.1 | RowcaUcsSwitchConnEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.3.4.1.1.1 | ColumncaUcsSwitchConnUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.3.4.1.1.2 | ColumncaUcsSwitchConnSwitchIndex | read-only | current | Index of an interface on a switch; same value as caSwitchIndex. |
| 1.3.6.1.4.1.546.16.58.3.3.4.1.1.3 | ColumncaUcsSwitchConnIfIndex | read-only | current | Index of an interface on a switch; same value as caSwitchIfIndex. |
| 1.3.6.1.4.1.546.16.58.3.3.4.1.1.4 | ColumncaUcsSwitchConnChassisId | read-only | current | The value of caChassisId that contains the fabric extender taht is connected to this switch port. |
| 1.3.6.1.4.1.546.16.58.3.3.4.1.1.5 | ColumncaUcsSwitchConnFabricExtenderSlotId | read-only | current | The value of caUcsFabricExtenderSlotId connected to this particular port or 0 if the port is not a backplane port. |
| 1.3.6.1.4.1.546.16.58.3.3.4.1.1.6 | ColumncaUcsSwitchConnFabricExtenderPortIndex | read-only | current | The value of caUcsFabricExtenderPortIndex connected to this particular port or 0 if the port is not a backplane port. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2 | TablecaUcsSwitchIfEthStatsTable | not-accessible | current | caUcsSwitchIfEthStats table. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1 | RowcaUcsSwitchIfEthStatsEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.1 | ColumncaUcsSwitchIfEthStatsUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.2 | ColumncaUcsSwitchIfEthStatsSwitchIndex | read-only | current | Index of the switch from the caSwitchTable. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.3 | ColumncaUcsSwitchIfEthStatsIndex | read-only | current | Index of an interface on a switch; corresponds to caSwitchIfIndex. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.4 | ColumncaUcsSwitchIfEthStatsAlign | read-only | current | Count of a number of alignment errors. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.5 | ColumncaUcsSwitchIfEthStatsDefferedTx | read-only | current | Count of a number of transmissions that were deferred. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.6 | ColumncaUcsSwitchIfEthStatsFcs | read-only | current | Count of the number of frame check sequence errors. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.7 | ColumncaUcsSwitchIfEthStatsIntMacRx | read-only | current | Count of the number of packets in error when received by the MAC layer. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.8 | ColumncaUcsSwitchIfEthStatsIntMacTx | read-only | current | Count of the number of packets in error when the MAC layer attempts to transmit. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.9 | ColumncaUcsSwitchIfEthStatsOutDiscard | read-only | current | Count of the number of packets discarded due to network congestion. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.10 | ColumncaUcsSwitchIfEthStatsRcv | read-only | current | Count of the total number of received packets in error. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.11 | ColumncaUcsSwitchIfEthStatsUnderSize | read-only | current | Count of the total number of packets received under 64 bytes in length. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.12 | ColumncaUcsSwitchIfEthStatsXmit | read-only | current | Count of the total number of transmission errors. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.13 | ColumncaUcsSwitchIfEthStatsSqeTest | read-only | current | Count of the number of failed SQE tests. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.14 | ColumncaUcsSwitchIfEthStatsCarrierSense | read-only | current | Count of the number of carrier sense errors. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.15 | ColumncaUcsSwitchIfEthStatsExcessCollision | read-only | current | Count of the number of packets dropped due to excess collisions. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.16 | ColumncaUcsSwitchIfEthStatsGiants | read-only | current | Count of the number of packets dropped because they are larger than the largest allowed packet on the medium. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.17 | ColumncaUcsSwitchIfEthStatsLateCollision | read-only | current | Count of the number of packets lost due to a late collision. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.18 | ColumncaUcsSwitchIfEthStatsMultiCollision | read-only | current | Count of the number of packets lost due to multiple collisions. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.19 | ColumncaUcsSwitchIfEthStatsSingleCollision | read-only | current | Count of the number of packets lost due to a single collision. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.20 | ColumncaUcsSwitchIfEthStatsSymbol | read-only | current | Count of the number of packets lost due to errors in encoding or decoding symbols. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.21 | ColumncaUcsSwitchIfEthStatsRecvPause | read-only | current | Count of the number or received 802.3x PAUSE packets. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.22 | ColumncaUcsSwitchIfEthStatsResets | read-only | current | Count of the number of 802.3x RESET packets. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.23 | ColumncaUcsSwitchIfEthStatsXmitPause | read-only | current | Count of the number of transmitted 802.3x PAUSE packets. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.24 | ColumncaUcsSwitchIfEthStatsRxJumboPackets | read-only | current | Count of the number of received jumbo packets. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.25 | ColumncaUcsSwitchIfEthStatsRxTotalPackets | read-only | current | Count of the total number of packets received. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.26 | ColumncaUcsSwitchIfEthStatsTxJumboPackets | read-only | current | Count of the number of transmitted jumbo packets. |
| 1.3.6.1.4.1.546.16.58.3.3.4.2.1.27 | ColumncaUcsSwitchIfEthStatsTxTotalPackets | read-only | current | Count of the total number of transmitted packets. |
| 1.3.6.1.4.1.546.16.58.3.3.4.3 | TablecaUcsSwitchIfFcStatsTable | not-accessible | current | caUcsSwitchIfFcStats table. |
| 1.3.6.1.4.1.546.16.58.3.3.4.3.1 | RowcaUcsSwitchIfFcStatsEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.3.4.3.1.1 | ColumncaUcsSwitchIfFcStatsUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.3.4.3.1.2 | ColumncaUcsSwitchIfFcStatsSwitchIndex | read-only | current | Index of the switch from the caSwitchTable; same value as caSwitchIndex. |
| 1.3.6.1.4.1.546.16.58.3.3.4.3.1.3 | ColumncaUcsSwitchIfFcStatsIndex | read-only | current | Index of an interface on a switch; same value as caSwitchIfIndex. |
| 1.3.6.1.4.1.546.16.58.3.3.4.3.1.4 | ColumncaUcsSwitchIfFcStatsCrcRx | read-only | current | Count of the number of received fibre channel packets which failed their cyclical redundancy checks. |
| 1.3.6.1.4.1.546.16.58.3.3.4.3.1.5 | ColumncaUcsSwitchIfFcStatsLinkFailures | read-only | current | Count of the number of fibre chennel errors that cause a link to fail. |
| 1.3.6.1.4.1.546.16.58.3.3.4.3.1.6 | ColumncaUcsSwitchIfFcStatsRx | read-only | current | Count of the number of errors that occurred while receiving fibre channel traffic. |
| 1.3.6.1.4.1.546.16.58.3.3.4.3.1.7 | ColumncaUcsSwitchIfFcStatsSignalLosses | read-only | current | Count of the number of signal losses that occurred on a fibre channel interface. |
| 1.3.6.1.4.1.546.16.58.3.3.4.3.1.8 | ColumncaUcsSwitchIfFcStatsSyncLosses | read-only | current | Count of the number of synchronization errors that occurred on a fibre channel interface. |
| 1.3.6.1.4.1.546.16.58.3.3.4.3.1.9 | ColumncaUcsSwitchIfFcStatsTooLongRx | read-only | current | Count of the number of frames received that were longer than their indicated length. |
| 1.3.6.1.4.1.546.16.58.3.3.4.3.1.10 | ColumncaUcsSwitchIfFcStatsTooShortRx | read-only | current | Count of the number of frames received that were shorter than their indicated length. |
| 1.3.6.1.4.1.546.16.58.3.3.4.3.1.11 | ColumncaUcsSwitchIfFcStatsTx | read-only | current | Count of the number of errors that occurred during transmission of fibre channel traffic. |
| 1.3.6.1.4.1.546.16.58.3.4 | NodecaUcsManager | |||
| 1.3.6.1.4.1.546.16.58.3.4.1 | TablecaUcsManagerTable | not-accessible | current | caUcsManager table. |
| 1.3.6.1.4.1.546.16.58.3.4.1.1 | RowcaUcsManagerEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.4.1.1.1 | ColumncaUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.4.1.1.2 | ColumncaUcsManagerIpAddressType | read-only | current | IP address type of the UCS Manager. This is an enumerated INTEGER of type InetAddressType. |
| 1.3.6.1.4.1.546.16.58.3.4.1.1.3 | ColumncaUcsManagerIpAddress | read-only | current | IP address of the UCS Manager. |
| 1.3.6.1.4.1.546.16.58.3.4.1.1.4 | ColumncaUcsManagerMode | read-only | current | Running mode of the UCS Manager. |
| 1.3.6.1.4.1.546.16.58.3.4.1.1.5 | ColumncaUcsManagerName | read-only | current | Name of the UCS Manager. |
| 1.3.6.1.4.1.546.16.58.3.4.1.1.6 | ColumncaUcsManagerVersion | read-only | current | Version of the UCS Manager that is currently running. |
| 1.3.6.1.4.1.546.16.58.3.4.1.1.7 | ColumncaUcsManagerStartupVersion | read-only | current | Startup version of the UCS Manager. |
| 1.3.6.1.4.1.546.16.58.3.4.1.1.8 | ColumncaUcsManagerSysUpTime | read-only | current | Number of seconds the UCS Manager has been running. |
| 1.3.6.1.4.1.546.16.58.3.4.1.1.9 | ColumncaUcsManagerConnectionStatus | read-only | current | UCS manager connection status |
| 1.3.6.1.4.1.546.16.58.3.4.2 | ScalarcaUcsManagerTableLastChange | read-only | current | Last table refresh time |
| 1.3.6.1.4.1.546.16.58.3.5 | NodecaUcsServiceProfile | |||
| 1.3.6.1.4.1.546.16.58.3.5.1 | TablecaUcsServiceProfileTable | not-accessible | current | caUcsServiceProfile table. |
| 1.3.6.1.4.1.546.16.58.3.5.1.1 | RowcaUcsServiceProfileEntry | not-accessible | current | The table entry. |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.1 | ColumncaUcsServiceProfileUcsManagerId | read-only | current | UCS Manager id |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.2 | ColumncaUcsServiceProfileIntId | read-only | current | Internal Id of a service profile |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.3 | ColumncaUcsServiceProfileName | read-only | current | Name of the Service Profile. |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.4 | ColumncaUcsServiceProfileDescription | read-only | current | Name of the Service Profile. |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.5 | ColumncaUcsServiceProfileBladeIndex | read-only | current | Index of a blade in a chassis for referencing caBladeTable and caUcsBladeTable. Note that this info won't be available if no blades are assigned to the service… |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.6 | ColumncaUcsServiceProfileBladeDn | read-only | current | Dn of the blade that is associated with the service profile. Note that this info won't be available if no blades are assigned to the service profile. |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.7 | ColumncaUcsServiceProfileBladeFullyQualifiedDn | read-only | current | Concatenation of UCS Manager name with the Dn of the blade. Note that this info won't be available if no blades are assigned to the service profile. |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.8 | ColumncaUcsServiceProfileAssignedState | read-only | current | Service profile assigned state |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.9 | ColumncaUcsServiceProfileAssociationState | read-only | current | Service profile association state |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.10 | ColumncaUcsServiceProfileConfigState | read-only | current | Service profile configuration state |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.11 | ColumncaUcsServiceProfileOperState | read-only | current | Service profile operating state |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.12 | ColumncaUcsServiceProfileDn | read-only | current | Dn of the service profile. |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.13 | ColumncaUcsServiceProfileFullyQualifiedDn | read-only | current | Concatenation of UCS Manager name with the Dn of the service profile. |
| 1.3.6.1.4.1.546.16.58.3.5.1.1.14 | ColumncaUcsServiceProfileBladeOid | read-only | current | Reference blade index <UCS Manager Id>,<blade index> with full OID path |
| 1.3.6.1.4.1.546.16.58.3.5.2 | ScalarcaUcsServiceProfileTableLastChange | read-only | current | Last table refresh time |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Float | Integer32 | current | This data type represents a Float. 9456 represents 94.56%... |
| Uint64 | Counter64 | current | This data type represents an unsigned 64 bit Limited to use in OBJECT-TYPE where the ACCESS clause is 'read-only' or 'accessible-for-notify'. |