MIB Viewer

EMPIRE-CACUCSEXTENSIONA-MIB

556 objects
This MIB module defines the Cisco Universal Computing System Aim extension tables.
OIDNameAccessStatusDescription
1.3.6.1.4.1.546Nodeempire
1.3.6.1.4.1.546.1Nodeunix
1.3.6.1.4.1.546.1.1Nodesysmgmt
1.3.6.1.4.1.546.1.1.165526NotificationcaUcsChassisFabricExtenderRemovedTrapcurrentA fabric extender module has been removed from a chassis.
1.3.6.1.4.1.546.1.1.165527NotificationcaUcsChassisFabricExtenderPortFailureTrapcurrentA port on a fabric extender has failed due to hardware failure.
1.3.6.1.4.1.546.1.1.165528NotificationcaUcsChassisFabricExtenderPortLinkDownTrapcurrentA port on a fabric extender has lost its link.
1.3.6.1.4.1.546.9Nodetraps
1.3.6.1.4.1.546.9.165526NodecaUcsChassisFabricExtenderRemovedEvent
1.3.6.1.4.1.546.9.165527NodecaUcsChassisFabricExtenderPortFailureEvent
1.3.6.1.4.1.546.9.165528NodecaUcsChassisFabricExtenderPortLinkDownEvent
1.3.6.1.4.1.546.16Nodeapplications
1.3.6.1.4.1.546.16.58Nodecadatacentera
1.3.6.1.4.1.546.16.58.3IdentitycaUcsExtensionsThis MIB module defines the Cisco Universal Computing System Aim extension tables.
1.3.6.1.4.1.546.16.58.3.1NodecaUcsChassisExt
1.3.6.1.4.1.546.16.58.3.1.1NodecaUcsChassis
1.3.6.1.4.1.546.16.58.3.1.1.1ScalarinclausecurrentcaUcsChassis table.
1.3.6.1.4.1.546.16.58.3.1.1.2ScalarcaUcsChassisTableLastChangeread-onlycurrentTable tast refresh time
1.3.6.1.4.1.546.16.58.3.1.2NodecaUcsChassisFan
1.3.6.1.4.1.546.16.58.3.1.2.1TablecaUcsChassisFanTablenot-accessiblecurrentcaUcsChassisFan table.
1.3.6.1.4.1.546.16.58.3.1.2.1.1RowcaUcsChassisFanEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.1.2.1.1.1ColumncaUcsChassisFanUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.1.2.1.1.2ColumncaUcsChassisFanChassisIdread-onlycurrentInstance of a chassis/enclosure; corresponds to caChassisId.
1.3.6.1.4.1.546.16.58.3.1.2.1.1.3ColumncaUcsChassisFanIndexread-onlycurrentInstance of a fan.
1.3.6.1.4.1.546.16.58.3.1.2.1.1.4ColumncaUcsChassisFanAmbientTempread-onlycurrentDegrees celsius.
1.3.6.1.4.1.546.16.58.3.1.2.1.1.5ColumncaUcsChassisFanOperStateread-onlycurrentOperational state of the fan.
1.3.6.1.4.1.546.16.58.3.1.2.1.1.6ColumncaUcsChassisFanTrayread-onlycurrentThe chassis trap containing the fan.
1.3.6.1.4.1.546.16.58.3.1.2.1.1.7ColumncaUcsChassisFanModuleread-onlycurrentA module contained within a tray.
1.3.6.1.4.1.546.16.58.3.1.2.1.1.8ColumncaUcsChassisFanIdread-onlycurrentThe idntifier of the fan; may be the same as caChcssisFanIndex.
1.3.6.1.4.1.546.16.58.3.1.2.1.1.9ColumncaUcsChassisFanOperabilityread-onlycurrentOperability of the chassis fan.
1.3.6.1.4.1.546.16.58.3.1.2.1.1.10ColumncaUcsChassisFanPerformanceread-onlycurrentChassis fan performance
1.3.6.1.4.1.546.16.58.3.1.2.1.1.11ColumncaUcsChassisFanPowerread-onlycurrentChassis fan power status
1.3.6.1.4.1.546.16.58.3.1.3NodecaUcsChassisPower
1.3.6.1.4.1.546.16.58.3.1.3.1TablecaUcsChassisPsuTablenot-accessiblecurrentcaUcsChassisPsu table.
1.3.6.1.4.1.546.16.58.3.1.3.1.1RowcaUcsChassisPsuEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.1.3.1.1.1ColumncaUcsChassisPsuUcsManagerIdread-onlycurrentThe configured switch to use for connectivity.
1.3.6.1.4.1.546.16.58.3.1.3.1.1.2ColumncaUcsChassisPsuChassisIdread-onlycurrentInstance of a chassis/enclosure; corresponds to caChassisId.
1.3.6.1.4.1.546.16.58.3.1.3.1.1.3ColumncaUcsChassisPsuIndexread-onlycurrentId unique within the context of the chassis.
1.3.6.1.4.1.546.16.58.3.1.3.1.1.4ColumncaUcsChassisPsuAmbientTempread-onlycurrentTemperature, in celsius, sensed by the PSU.
1.3.6.1.4.1.546.16.58.3.1.3.1.1.5ColumncaUcsChassisPsuOperStateread-onlycurrentOperational state of the fan.
1.3.6.1.4.1.546.16.58.3.1.3.1.1.6ColumncaUcsChassisPsuInput210vread-onlycurrentActual voltage drawn by the PSU on the 210v input.
1.3.6.1.4.1.546.16.58.3.1.3.1.1.7ColumncaUcsChassisPsuOutput12vread-onlycurrentActual volage put out by the PSU on the 12 volt rail(s).
1.3.6.1.4.1.546.16.58.3.1.3.1.1.8ColumncaUcsChassisPsuOutput3v3read-onlycurrentActual volage put out by the PSU on the 3.3 volt rail(s).
1.3.6.1.4.1.546.16.58.3.1.3.1.1.9ColumncaUcsChassisPsuOperabilityread-onlycurrentOperability of the fan.
1.3.6.1.4.1.546.16.58.3.1.3.1.1.10ColumncaUcsChassisPsuPerformanceread-onlycurrentChassis Psu performance
1.3.6.1.4.1.546.16.58.3.1.3.1.1.11ColumncaUcsChassisPsuPowerread-onlycurrentChassis Psu power status
1.3.6.1.4.1.546.16.58.3.1.4NodecaUcsChassisFabricExtender
1.3.6.1.4.1.546.16.58.3.1.4.1ScalarcaUcsChassisFabricExtenderTableLastChangeread-onlycurrentThe value of sysUpTime at the time of the last creation or deletion of an entry in the caUcsChassisFabricExtenderTable. If the number of entries has been uncha…
1.3.6.1.4.1.546.16.58.3.1.4.2TablecaUcsChassisFabricExtenderTablenot-accessiblecurrentcaUcsChassisFabricExtender table.
1.3.6.1.4.1.546.16.58.3.1.4.2.1RowcaUcsChassisFabricExtenderEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.1ColumncaUcsChassisFabricExtenderUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.1.4.2.1.2ColumncaUcsChassisFabricExtenderChassisIdread-onlycurrentInstance of a chassis/enclosure; corresponds to caChassisId.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.3ColumncaUcsChassisFabricExtenderSlotIdread-onlycurrentInstance of a fabric extender and the slot in which it is installed.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.4ColumncaUcsChassisFabricExtenderModelread-onlycurrentModel of the fabric extender.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.5ColumncaUcsChassisFabricExtenderSerialNumberread-onlycurrentSerial number of the fabric extender.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.6ColumncaUcsChassisFabricExtenderVendorread-onlycurrentVendor of the fabric extender.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.7ColumncaUcsChassisFabricExtenderRevisionread-onlycurrentRevision of the model of the fabric extender.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.8ColumncaUcsChassisFabricExtenderSideread-onlycurrentSide of the chassis in which the fabric extender is installed.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.9ColumncaUcsChassisFabricExtenderAmbientTempread-onlycurrentDegrees celsius.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.10ColumncaUcsChassisFabricExtenderOperStateread-onlycurrentOperational state of the fabric extender.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.11ColumncaUcsChassisFabricExtenderBootLoaderVersionread-onlycurrentVersion of the boot loader firmware that is running currently.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.12ColumncaUcsChassisFabricExtenderFirmwareVersionread-onlycurrentVersion of the firmware that is currently running.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.13ColumncaUcsChassisFabricExtenderStartupFirmwareVersionread-onlycurrentStartup version of the firmware.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.14ColumncaUcsChassisFabricExtenderBackupFirmwareVersionread-onlycurrentBackup version of the firmware.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.15ColumncaUcsChassisFabricExtenderOperabilityread-onlycurrentOperability of the fabric extender.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.16ColumncaUcsChassisFabricExtenderProductNameread-onlycurrentProduct name of the fabric extender.
1.3.6.1.4.1.546.16.58.3.1.4.2.1.17ColumncaUcsChassisFabricExtenderPidread-onlycurrentPid of the fabric extender.
1.3.6.1.4.1.546.16.58.3.1.4.3ScalarcaUcsChassisFabricExtenderPortTableLastChangeread-onlycurrentThe value of sysUpTime at the time of the last creation or deletion of an entry in the caUcsChassisFabricExtenderPortTable. If the number of entries has been u…
1.3.6.1.4.1.546.16.58.3.1.4.4TablecaUcsChassisFabricExtenderPortTablenot-accessiblecurrentcaUcsChassisFabricExtenderPort table.
1.3.6.1.4.1.546.16.58.3.1.4.4.1RowcaUcsChassisFabricExtenderPortEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.1.4.4.1.1ColumncaUcsChassisFabricExtenderPortUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.1.4.4.1.2ColumncaUcsChassisFabricExtenderPortChassisIdread-onlycurrentInstance of a chassis/enclosure; corresponds to caChassisId.
1.3.6.1.4.1.546.16.58.3.1.4.4.1.3ColumncaUcsChassisFabricExtenderPortIndexread-onlycurrentInstance of a port on a fabric extender.
1.3.6.1.4.1.546.16.58.3.1.4.4.1.4ColumncaUcsChassisFabricExtenderPortSlotIdread-onlycurrentInstance of a fabric extender and the slot in which it is installed.
1.3.6.1.4.1.546.16.58.3.1.4.4.1.5ColumncaUcsChassisFabricExtenderPortModelread-onlycurrentModel of the fabric extender port.
1.3.6.1.4.1.546.16.58.3.1.4.4.1.6ColumncaUcsChassisFabricExtenderPortSerialNumberread-onlycurrentSerial number of the fabric extender port.
1.3.6.1.4.1.546.16.58.3.1.4.4.1.7ColumncaUcsChassisFabricExtenderPortVendorread-onlycurrentVendor of the fabric extender port.
1.3.6.1.4.1.546.16.58.3.1.4.4.1.8ColumncaUcsChassisFabricExtenderPortRevisionread-onlycurrentRevision of the model of the fabric extender port.
1.3.6.1.4.1.546.16.58.3.1.4.4.1.9ColumncaUcsChassisFabricExtenderPortTyperead-onlycurrentWhat type of port this represents.
1.3.6.1.4.1.546.16.58.3.1.4.4.1.10ColumncaUcsChassisFabricExtenderDeviceIndexread-onlycurrentThe device connected to this fabric extender port. Connected devices, if known, are either a switch or a blade. If this is a switch port, this is the value of …
1.3.6.1.4.1.546.16.58.3.1.4.4.1.11ColumncaUcsChassisFabricExtenderConnectedPortIndexread-onlycurrentThe port of the device connected to this fabric extender port. If this is a switch port, then this is the index into the caSwitchInterfaceTable. If this is a s…
1.3.6.1.4.1.546.16.58.3.1.4.4.1.12ColumncaUcsChassisFabricExtenderPortOperStateread-onlycurrentoperating state of the extender port
1.3.6.1.4.1.546.16.58.3.1.4.4.1.13ColumncaUcsChassisFabricExtenderPortPeerSlotIdread-onlycurrentPeer slot id of the fabric extender port
1.3.6.1.4.1.546.16.58.3.1.4.4.1.14ColumncaUcsChassisFabricExtenderPortAcknowledgeread-onlycurrentOnly available for fabric not for host port
1.3.6.1.4.1.546.16.58.3.1.4.4.1.15ColumncaUcsChassisFabricExtenderPortPeerDnread-onlycurrentPeer Dn
1.3.6.1.4.1.546.16.58.3.1.4.4.1.16ColumncaUcsChassisFabricExtenderPortProductNameread-onlycurrentProduct name of the extender port
1.3.6.1.4.1.546.16.58.3.1.4.4.1.17ColumncaUcsChassisFabricExtenderPortPidread-onlycurrentPid of the extender port
1.3.6.1.4.1.546.16.58.3.1.4.4.1.18ColumncaUcsChassisFabricExtenderPortPeerFullyQualifiedDnread-onlycurrentPeer fully qualified Dn
1.3.6.1.4.1.546.16.58.3.1.4.4.1.19ColumncaUcsChassisFabricExtenderPortSwitchIdread-onlycurrentswitch id that port is connected to
1.3.6.1.4.1.546.16.58.3.2NodecaUcsBladeExt
1.3.6.1.4.1.546.16.58.3.2.1NodecaUcsBlade
1.3.6.1.4.1.546.16.58.3.2.1.1TablecaUcsBladeTablenot-accessiblecurrentcaUCSBlade table.
1.3.6.1.4.1.546.16.58.3.2.1.1.1RowcaUcsBladeEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.1ColumncaUcsBladeUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.1.1.1.2ColumncaUcsBladeIndexread-onlycurrentInstance of a blade in a chassis.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.3ColumncaUcsBladeOperStateread-onlycurrentOperational state of the blade.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.4ColumncaUcsBladeBootLoaderFirmwareVersionread-onlycurrentVersion of the boot loader firmware that is running currently.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.5ColumncaUcsBladeSystemFirmwareVersionread-onlycurrentVersion of the system firmware.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.6ColumncaUcsBladeBackupFirmwareVersionread-onlycurrentBackup version of the system firmware.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.7ColumncaUcsBladeBiosVersionread-onlycurrentCurrent running version of the BIOS.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.8ColumncaUcsBladeRestartBiosVersionread-onlycurrentVersion of the BIOS that will be loaded at reboot.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.9ColumncaUcsBladeBiosBootSequenceread-onlycurrentSequence of devices the BIOS uses to find a boot image, separated by commas.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.10ColumncaUcsBladeNumOfAdaptorsread-onlycurrentNumber of mezzanine cards in the blade.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.11ColumncaUcsBladeNumOfCpusread-onlycurrentNumber of CPUs installed on the blade.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.12ColumncaUcsBladeNumOfCoresread-onlycurrentTotal number of cores across all CPUs on the blade.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.13ColumncaUcsBladeNumOfEthernetIfsread-onlycurrentTotal number of Ethernet interfaces as seen by software hosted on the blade.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.14ColumncaUcsBladeNumOfFcIfsread-onlycurrentTotal number of Fibre Channel interfaces as seen by software hosted on the blade.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.15ColumncaUcsBladeAvailableMemoryread-onlycurrentAvailable memory in MBs.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.16ColumncaUcsBladeCachedMemoryread-onlycurrentCached memory in MBs.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.17ColumncaUcsBladeTotalMemoryread-onlycurrentTotal memory in MBs.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.18ColumncaUcsBladeAvailableSwapMemoryread-onlycurrentAvailable swap memory in MBs.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.19ColumncaUcsBladeCachedSwapMemoryread-onlycurrentCached swap memory in MBs.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.20ColumncaUcsBladeTotalSwapMemoryread-onlycurrentTotal swap memory in MBs.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.21ColumncaUcsBladeAssignedToDnread-onlycurrentThis DN is used for power up/down operation.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.22ColumncaUcsBladeOperabilityread-onlycurrentOperability of the blade.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.23ColumncaUcsBladeDiscoveryread-onlycurrentDiscovery status of the blade
1.3.6.1.4.1.546.16.58.3.2.1.1.1.24ColumncaUcsBladeNumOfThreadsread-onlycurrentTotal number of CPU threads
1.3.6.1.4.1.546.16.58.3.2.1.1.1.25ColumncaUcsBladeOperPowerread-onlycurrentOperating power of the blade.
1.3.6.1.4.1.546.16.58.3.2.1.1.1.26ColumncaUcsBladeOperQualifierread-onlycurrentBlade configuration error
1.3.6.1.4.1.546.16.58.3.2.1.1.1.27ColumncaUcsBladeAdminStateread-onlycurrentAdmin state of the blade
1.3.6.1.4.1.546.16.58.3.2.1.1.1.28ColumncaUcsBladeAvailableStateread-onlycurrentAvailability of the blade
1.3.6.1.4.1.546.16.58.3.2.1.1.1.29ColumncaUcsBladeAssociateStateread-onlycurrentService profile association state
1.3.6.1.4.1.546.16.58.3.2.1.1.1.30ColumncaUcsBladeSlotStatusread-onlycurrentSlot status of the blade
1.3.6.1.4.1.546.16.58.3.2.1.1.1.31ColumncaUcsBladeCheckPointread-onlycurrentCheckpoint
1.3.6.1.4.1.546.16.58.3.2.1.1.1.32ColumncaUcsBladeAssignedToFullyQualifiedDnread-onlycurrentThis fully qualified DN
1.3.6.1.4.1.546.16.58.3.2.1.1.1.33ColumncaUcsBladeServiceProfileOidread-onlycurrentReference service profile index <UCS Manager Id>,<Service Profile internal id> with full OID path
1.3.6.1.4.1.546.16.58.3.2.1.2ScalarcaUcsBladeTableLastChangeread-onlycurrentTable tast refresh time
1.3.6.1.4.1.546.16.58.3.2.2NodecaUcsBladeInterfaces
1.3.6.1.4.1.546.16.58.3.2.2.1TablecaUcsBladeIfTablenot-accessiblecurrentcaUcsBladeIf table.
1.3.6.1.4.1.546.16.58.3.2.2.1.1RowcaUcsBladeIfEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.2.1.1.1ColumncaUcsBladeIfUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.2.1.1.2ColumncaUcsBladeIfBladeIndexread-onlycurrentIndex of the blade from the caBladeTable.
1.3.6.1.4.1.546.16.58.3.2.2.1.1.3ColumncaUcsBladeIfIndexread-onlycurrentIndex of an interface on a blade; corresponds to caBladeIfIndex.
1.3.6.1.4.1.546.16.58.3.2.2.1.1.4ColumncaUcsBladeIfFirmwareVersionread-onlycurrentVersion of the firmware that is currently running or a zero-length string if the value is not known or does not apply.
1.3.6.1.4.1.546.16.58.3.2.2.1.1.5ColumncaUcsBladeIfStartupFirmwareVersionread-onlycurrentStartup version of the firmware or a zero-length string if the value is not known or does not apply.
1.3.6.1.4.1.546.16.58.3.2.2.1.1.6ColumncaUcsBladeIfFabricExtenderSlotIdread-onlycurrentThe value of caUcsFabricExtenderSlotId connected to this particular port or 0 if the port is not a backplane port.
1.3.6.1.4.1.546.16.58.3.2.2.1.1.7ColumncaUcsBladeIfFabricExtenderPortIndexread-onlycurrentThe value of caUcsFabricExtenderPortIndex connected to this particular port or 0 if the port is not a backplane port.
1.3.6.1.4.1.546.16.58.3.2.2.2TablecaUcsBladeIfEthStatsTablenot-accessiblecurrentcaUcsBladeIfEthStats table.
1.3.6.1.4.1.546.16.58.3.2.2.2.1RowcaUcsBladeIfEthStatsEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.1ColumncaUcsBladeIfEthStatsUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.2.2.1.2ColumncaUcsBladeIfEthStatsBladeIndexread-onlycurrentIndex of the blade from the caBladeTable.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.3ColumncaUcsBladeIfEthStatsIfIndexread-onlycurrentIndex of an interface on a blade; corresponds to caBladeIfIndex.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.4ColumncaUcsBladeIfEthStatsTxGreaterThanOrEqualTo9216read-onlycurrentCount of transmitted packets with length greater than or equal to 9216 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.5ColumncaUcsBladeIfEthStatsRxGreaterThanOrEqualTo9216read-onlycurrentCount of received packets with length greater than or equal to 9216 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.6ColumncaUcsBladeIfEthStatsTxLessThan2048read-onlycurrentCount of transmitted packets with length greater than 1518 bytes and less than 2048.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.7ColumncaUcsBladeIfEthStatsRxLessThan2048read-onlycurrentCount of received packets with length greater than 1518 bytes and less than 2048.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.8ColumncaUcsBladeIfEthStatsTxLessThan4096read-onlycurrentCount of transmitted packets with length greater than 2048 bytes and less than 4096 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.9ColumncaUcsBladeIfEthStatsRxLessThan4096read-onlycurrentCount of received packets with length greater than 2048 bytes nd less than 4096 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.10ColumncaUcsBladeIfEthStatsTxLessThan8192read-onlycurrentCount of transmitted packets with length greater than 4096 bytes and less tahn 8192 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.11ColumncaUcsBladeIfEthStatsRxLessThan8192read-onlycurrentCount of received packets with length greater than 4096 bytes and less tahn 8192 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.12ColumncaUcsBladeIfEthStatsTxLessThan9216read-onlycurrentCount of transmitted packets with length greater than 8192 bytes and less than 9216 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.13ColumncaUcsBladeIfEthStatsRxLessThan9216read-onlycurrentCount of received packets with length greater than 8192 bytes and less than 9216 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.14ColumncaUcsBladeIfEthStatsTxLessThanOrEqualTo1518read-onlycurrentCount of transmitted packets with length greater than or equal to 1518 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.15ColumncaUcsBladeIfEthStatsRxLessThanOrEqualTo1518read-onlycurrentCount of received packets with length greater than or equal to 1518 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.16ColumncaUcsBladeIfEthStatsTxEquals64read-onlycurrentCount of transmitted packets with length equal to 64 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.17ColumncaUcsBladeIfEthStatsRxEquals64read-onlycurrentCount of received packets with length equal to 64 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.18ColumncaUcsBladeIfEthStatsTxLessThan1024read-onlycurrentCount of transmitted packets with length greater than or equal to 512 bytes and less than 1024 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.19ColumncaUcsBladeIfEthStatsRxLessThan1024read-onlycurrentCount of received packets with length greater than or equal to 512 bytes and less than 1024 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.20ColumncaUcsBladeIfEthStatsTxLessThan128read-onlycurrentCount of transmitted packets with length greater than 64 bytes and less than 128 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.21ColumncaUcsBladeIfEthStatsRxLessThan128read-onlycurrentCount of received packets with length greater than 64 bytes and less than 128 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.22ColumncaUcsBladeIfEthStatsTxLessThan256read-onlycurrentCount of transmitted packets with length greater than or equal to 128 bytes and less than 256 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.23ColumncaUcsBladeIfEthStatsRxLessThan256read-onlycurrentCount of received packets with length greater than or equal to 128 bytes and less than 256 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.24ColumncaUcsBladeIfEthStatsTxLessThan512read-onlycurrentCount of transmitted packets with length greater than or equal to 256 bytes and less than 512 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.25ColumncaUcsBladeIfEthStatsRxLessThan512read-onlycurrentCount of received packets with length greater than or equal to 256 bytes and less than 512 bytes.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.26ColumncaUcsBladeIfEthStatsTxBadCrcPacketsread-onlycurrentCount of transmitted packets which failed their CRC.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.27ColumncaUcsBladeIfEthStatsRxBadCrcPacketsread-onlycurrentCount of received packets which failed their CRC.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.28ColumncaUcsBladeIfEthStatsTxBadLengthPacketsread-onlycurrentCount of transmitted packets with incorrect length values.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.29ColumncaUcsBladeIfEthStatsRxBadLengthPacketsread-onlycurrentCount of received packets with incorrect length values.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.30ColumncaUcsBladeIfEthStatsTxOversizedBadCrcPacketsread-onlycurrentCount of transmitted oversized packets which failed their CRC.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.31ColumncaUcsBladeIfEthStatsRxOversizedBadCrcPacketsread-onlycurrentCount of received oversized packets which failed their CRC.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.32ColumncaUcsBladeIfEthStatsTxOversizedGoodCrcPacketsread-onlycurrentCount of transmitted oversized packets with correct CRCs.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.33ColumncaUcsBladeIfEthStatsRxOversizedGoodCrcPacketsread-onlycurrentCount of received oversized packets with correct CRCs.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.34ColumncaUcsBladeIfEthStatsTxOversizedPacketsread-onlycurrentCount of transmitted oversize packets.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.35ColumncaUcsBladeIfEthStatsRxOversizedPacketsread-onlycurrentCount of received oversize packets.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.36ColumncaUcsBladeIfEthStatsTxUndersizedBadCrcPacketsread-onlycurrentCount of transmitted undersized packets which failed their CRC.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.37ColumncaUcsBladeIfEthStatsRxUndersizedBadCrcPacketsread-onlycurrentCount of received undersized packets which failed their CRC.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.38ColumncaUcsBladeIfEthStatsTxUndersizedGoodCrcPacketsread-onlycurrentCount of transmitted undersized packets with correct CRCs.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.39ColumncaUcsBladeIfEthStatsRxUndersizedGoodCrcPacketsread-onlycurrentCount of received undersized packets with correct CRCs.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.40ColumncaUcsBladeIfEthStatsTxGoodPacketsread-onlycurrentCount of transmitted good packets.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.41ColumncaUcsBladeIfEthStatsRxGoodPacketsread-onlycurrentCount of received good packets.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.42ColumncaUcsBladeIfEthStatsTxPausePacketsread-onlycurrentCount of transmitted pause packets.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.43ColumncaUcsBladeIfEthStatsRxPausePacketsread-onlycurrentCount of received pause packets.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.44ColumncaUcsBladeIfEthStatsTxPerPriorityPausePacketsread-onlycurrentCount of pause packets transmitted per priority.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.45ColumncaUcsBladeIfEthStatsRxPerPriorityPausePacketsread-onlycurrentCount of pause packets received per priority.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.46ColumncaUcsBladeIfEthStatsTxPppPacketsread-onlycurrentCount of transmitted PPP packets.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.47ColumncaUcsBladeIfEthStatsRxPppPacketsread-onlycurrentCount of received PPP packets.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.48ColumncaUcsBladeIfEthStatsTxTotalPacketsread-onlycurrentCount of transmitted packets.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.49ColumncaUcsBladeIfEthStatsRxTotalPacketsread-onlycurrentCount of transmitted packets.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.50ColumncaUcsBladeIfEthStatsTxVlanPacketsread-onlycurrentCount of transmitted VLAN packets.
1.3.6.1.4.1.546.16.58.3.2.2.2.1.51ColumncaUcsBladeIfEthStatsRxVlanPacketsread-onlycurrentCount of received VLAN packets.
1.3.6.1.4.1.546.16.58.3.2.2.3TablecaUcsBladeIfFcStatsTablenot-accessiblecurrentcaUcsBladeIfFcStats table.
1.3.6.1.4.1.546.16.58.3.2.2.3.1RowcaUcsBladeIfFcStatsEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.1ColumncaUcsBladeIfFcStatsUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.2.3.1.2ColumncaUcsBladeIfFcStatsBladeIndexread-onlycurrentIndex of the blade from the caBladeTable.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.3ColumncaUcsBladeIfFcStatsIfIndexread-onlycurrentIndex of an interface on a blade; corresponds to caBladeIfIndex.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.4ColumncaUcsBladeIfFcStatsInvalidCRCCountread-onlycurrentNumber of frames received with invalid CRC.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.5ColumncaUcsBladeIfFcStatsLinkFailureCountread-onlycurrentNumber of times a link error has occurred.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.6ColumncaUcsBladeIfFcStatsLipCountread-onlycurrentNumber of LIP events that have occurred on an arbitrated loop.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.7ColumncaUcsBladeIfFcStatsLossOfSignalCountread-onlycurrentNumber of times loss of signal has occurred.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.8ColumncaUcsBladeIfFcStatsLossOfSyncCountread-onlycurrentNumber of times loss of sync has occurred.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.9ColumncaUcsBladeIfFcStatsNOSCountread-onlycurrentNumber of NOS events that have occurred on the switched Fabric.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.10ColumncaUcsBladeIfFcStatsControlRequestsread-onlycurrentNumber of FC-4 operations which are not intended to cause FC-4 data movement.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.11ColumncaUcsBladeIfFcStatsInputMegabytesread-onlycurrentNumber of megabytes of FC-4 data input.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.12ColumncaUcsBladeIfFcStatsInputRequestsread-onlycurrentNumber of FC-4 operations causing FC-4 data input. Some single FC-4 re-quests may cause both input and output of data (e.g., Bidirectional SCSI commands in FCP…
1.3.6.1.4.1.546.16.58.3.2.2.3.1.13ColumncaUcsBladeIfFcStatsOutputMegabytesread-onlycurrentNumber of megabytes of FC-4 data output.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.14ColumncaUcsBladeIfFcStatsOutputRequestsread-onlycurrentNumber of FC-4 operations causing FC-4 data output. Some single FC-4 re-quests may cause both input and output of data (e.g., Bidirectional SCSI commands in FC…
1.3.6.1.4.1.546.16.58.3.2.2.3.1.15ColumncaUcsBladeIfFcStatsDumpedFramesread-onlycurrentNumber of frames that were lost due to a lack of host buffers available.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.16ColumncaUcsBladeIfFcStatsErrorFramesread-onlycurrentNumber of frames that have been received in error.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.17ColumncaUcsBladeIfFcStatsRxFramesread-onlycurrentNumber of total Received Fibre Channel frames across all protocols and classes.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.18ColumncaUcsBladeIfFcStatsTxFramesread-onlycurrentNumber of total Transmitted Fibre Channel frames across all protocols and classes.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.19ColumncaUcsBladeIfFcStatsRxBadFramesread-onlycurrentNumber of invalid received Fibre Channel frames.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.20ColumncaUcsBladeIfFcStatsTotalRxFramesread-onlycurrentNumber of total received Fibre Channel frames accross all protocols and classes.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.21ColumncaUcsBladeIfFcStatsTxBadFramesread-onlycurrentNumber of invalid transmitted Fibre Channel frames.
1.3.6.1.4.1.546.16.58.3.2.2.3.1.22ColumncaUcsBladeIfFcStatsTotalTxFramesread-onlycurrentNumber of total transmitted Fibre Channel frames across all protocols and classes.
1.3.6.1.4.1.546.16.58.3.2.2.4TablecaUcsMenloStatsTablenot-accessiblecurrentcaUcsMenloStats table.
1.3.6.1.4.1.546.16.58.3.2.2.4.1RowcaUcsMenloStatsEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.1ColumncaUcsMenloStatsUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.2.4.1.2ColumncaUcsMenloStatsBladeIndexread-onlycurrentIndex of the blade for the caBladeTable.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.3ColumncaUcsMenloStatsIndexread-onlycurrentIndex of a Menlo instance on a blade.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.4ColumncaUcsMenloStatsCorrectableErrorsread-onlycurrentCount of the number of packets that have correctable errors.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.5ColumncaUcsMenloStatsUncorrectableErrorsread-onlycurrentCount of the number of packets that have errors which could not be corrected.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.6ColumncaUcsMenloStatsDceRxPauseCFCread-onlycurrentCount of the number of received 802.3x PAUSE packets for congestion flow control on the Data Center Ethernet.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.7ColumncaUcsMenloStatsDceRxPausePFCread-onlycurrentCount of the number of received 802.3x PAUSE packets for priority flow control on the Data Center Ethernet.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.8ColumncaUcsMenloStatsDceTxPauseCFCread-onlycurrentCount of the number of transmitted 802.3x PAUSE packets for congestion flow control on the Data Center Ethernet.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.9ColumncaUcsMenloStatsDceTxPausePFCread-onlycurrentCount of the number of transmitted 802.3x PAUSE packets for priority flow control on the Data Center Ethernet.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.10ColumncaUcsMenloStatsEthCorrectableErrorsread-onlycurrentCount of the number of Ethernet packets that have correctable errors.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.11ColumncaUcsMenloStatsEthDropAclread-onlycurrentCount of the number of Ethernet packets dropped due to an access control list check.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.12ColumncaUcsMenloStatsEthPopErrorsread-onlycurrentCount of the number of Ethernet packets resulting in an error when popping them from a queue.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.13ColumncaUcsMenloStatsEthPushErrorsread-onlycurrentCount of the number of Ethernet packets resulting in an error when pushing them onto a queue.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.14ColumncaUcsMenloStatsEthUncorrectableErrorsread-onlycurrentCount of the number of Ethernet packets that have errors which could not be corrected.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.15ColumncaUcsMenloStatsEthDropOverrunread-onlycurrentCount of the number of Ethernet packets dropped due to a buffer overrun.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.16ColumncaUcsMenloStatsEthDropRuntread-onlycurrentCount of the number of Ethernet packets dropped due to being shorter than 64 bytes but having a valid CRC.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.17ColumncaUcsMenloStatsEthTruncateOverrunread-onlycurrentCount of the number of Ethernet packets carrying truncated Fibre Channel packets that caused a buffer overrun.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.18ColumncaUcsMenloStatsFcCorrectableErrorsread-onlycurrentCount of the number of Fibre Channel packets that have correctable errors.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.19ColumncaUcsMenloStatsFcPopErrorsread-onlycurrentCount of the number of Fiber Channel packets that caused an error when being popped from a queue.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.20ColumncaUcsMenloStatsFcPushErrorsread-onlycurrentCount of the number of Fibre Channel packets that caused an error when being pushed onto a queue.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.21ColumncaUcsMenloStatsFcUncorrectableErrorsread-onlycurrentCount of the number of Fibre Channel packets that have uncorrectable errors.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.22ColumncaUcsMenloStatsHostRxPauseCFCread-onlycurrentCount of the number of received 802.3x PAUSE packets for congestion flow control on the Host ports.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.23ColumncaUcsMenloStatsHostRxPausePFCread-onlycurrentCount of the number of received 802.3x PAUSE packets for priority flow control on the Host ports.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.24ColumncaUcsMenloStatsHostTxPauseCFCread-onlycurrentCount of the number of transmitted 802.3x PAUSE packets for congestion flow control on the Host ports.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.25ColumncaUcsMenloStatsHostTxPausePFCread-onlycurrentCount of the number of transmitted 802.3x PAUSE packets for priority flow control on the Host ports.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.26ColumncaUcsMenloStatsMcpuCorrectableErrorsread-onlycurrentCount of the number of correctable errors detected by the Menlo master central processing unit.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.27ColumncaUcsMenloStatsMcpuPopErrorsread-onlycurrentCount of the number of errors by the Menlo master central processing unit while popping packets from a queue.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.28ColumncaUcsMenloStatsMcpuPushErrorsread-onlycurrentCount of the number of errors by the Menlo master central processing unit while pushing packets on a queue.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.29ColumncaUcsMenloStatsMcpuUncorrectableErrorsread-onlycurrentCount of the number of uncorrectable errors detected by the Menlo master central processing unit.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.30ColumncaUcsMenloStatsMcpuDropAclread-onlycurrentCount of the number of packets dropped due to a check against an access control list by the Menlo master central processing unit.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.31ColumncaUcsMenloStatsMcpuDropOverrunread-onlycurrentCount of the number of packets dropped due to a buffer overrun by the Menlo master central processing unit.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.32ColumncaUcsMenloStatsMcpuDropRuntread-onlycurrentCount of the number of packets dropped due to an undersized packet with a correct CRC by the Menlo master central processing unit.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.33ColumncaUcsMenloStatsMcpuTruncateOverrunread-onlycurrentCount of the number of Ethernet packets carrying truncated Fibre Channel packets that caused a buffer overrun by the master central processing unit.
1.3.6.1.4.1.546.16.58.3.2.2.4.1.34ColumncaUcsMenloStatsNetEgDropCmdread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.4.1.35ColumncaUcsMenloStatsNetEgDropLifCfgInvalidread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.4.1.36ColumncaUcsMenloStatsNetEgDropLifMapNoHitread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.4.1.37ColumncaUcsMenloStatsNetEgDropSrcBindread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.4.1.38ColumncaUcsMenloStatsNetEgLearnReqDropread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.4.1.39ColumncaUcsMenloStatsNetInDropFcLifInvalidread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.4.1.40ColumncaUcsMenloStatsNetInDropFcMulticastread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.4.1.41ColumncaUcsMenloStatsNetInDropNullPifread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.4.1.42ColumncaUcsMenloStatsNetInFwdLookupNoHitread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.5TablecaUcsMenloQStatsTablenot-accessiblecurrentcaUcsMenloQStats table.
1.3.6.1.4.1.546.16.58.3.2.2.5.1RowcaUcsMenloQStatsEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.2.5.1.1ColumncaUcsMenloQStatsUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.2.5.1.2ColumncaUcsMenloQStatsBladeIndexread-onlycurrentIndex of the blade for the caBladeTable.
1.3.6.1.4.1.546.16.58.3.2.2.5.1.3ColumncaUcsMenloQStatsIndexread-onlycurrentIndex of a Menlo instance on a blade; same as caUcsMenloStatsIndex.
1.3.6.1.4.1.546.16.58.3.2.2.5.1.4ColumncaUcsMenloQStatsComponentIndexread-onlycurrentIndex of a Menlo component on a blade.
1.3.6.1.4.1.546.16.58.3.2.2.5.1.5ColumncaUcsMenloQStatsComponentIdread-onlycurrentThe type of Menlo compoennt to which the statistics of this instance apply.
1.3.6.1.4.1.546.16.58.3.2.2.5.1.6ColumncaUcsMenloQStatsCorrectableErrorsread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.5.1.7ColumncaUcsMenloQStatsPopErrorsread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.5.1.8ColumncaUcsMenloQStatsPushErrorsread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.5.1.9ColumncaUcsMenloQStatsUncorrectableErrorsread-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.5.1.10ColumncaUcsMenloQStatsDropOverrunN0read-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.5.1.11ColumncaUcsMenloQStatsDropOverrunN1read-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.5.1.12ColumncaUcsMenloQStatsTruncateOverrunN0read-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.5.1.13ColumncaUcsMenloQStatsTruncateOverrunN1read-onlycurrentblank
1.3.6.1.4.1.546.16.58.3.2.2.6TablecaUcsMezzanineTablenot-accessiblecurrentcaUcsMezzanine table.
1.3.6.1.4.1.546.16.58.3.2.2.6.1RowcaUcsMezzanineEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.1ColumncaUcsMezzanineUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.2.6.1.2ColumncaUcsMezzanineBladeIndexread-onlycurrentIndex of the blade for the caBladeTable.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.3ColumncaUcsMezzanineIndexread-onlycurrentIndex of a mezzanine card relative to the blade.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.4ColumncaUcsMezzanineModelread-onlycurrentModel of the mezzanine card.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.5ColumncaUcsMezzanineSerialNumberread-onlycurrentSerial number of the mezzanine card.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.6ColumncaUcsMezzanineVendorread-onlycurrentVendor of the mezzanine card.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.7ColumncaUcsMezzanineRevisionread-onlycurrentRevision of the model of the mezzanine card.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.8ColumncaUcsMezzanineConditionread-onlycurrentOverall status of the mezzanine card.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.9ColumncaUcsMezzanineBootLoaderVersionread-onlycurrentVersion of the boot loadeer firmware that is running currently.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.10ColumncaUcsMezzanineFirmwareVersionread-onlycurrentVersion of the firmware that is currently running.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.11ColumncaUcsMezzanineStartupFirmwareVersionread-onlycurrentStartup version of the firmware.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.12ColumncaUcsMezzanineBackupFirmwareVersionread-onlycurrentBackup version of the firmware.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.13ColumncaUcsMezzanineProductNameread-onlycurrentproduct name of the firmware.
1.3.6.1.4.1.546.16.58.3.2.2.6.1.14ColumncaUcsMezzaninePidread-onlycurrentPid of the firmware.
1.3.6.1.4.1.546.16.58.3.2.3NodecaUcsBladeServer
1.3.6.1.4.1.546.16.58.3.2.3.1NodecaUcsBladeServerCpu
1.3.6.1.4.1.546.16.58.3.2.3.1.1TablecaUcsCpuTablenot-accessiblecurrentUCS Cpu table.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1RowcaUcsCpuEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.1ColumncaUcsCpuUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.2ColumncaUcsCpuBladeIndexread-onlycurrentCorresponds to caBladeIndes.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.3ColumncaUcsCpuIndexread-onlycurrentInstance of a CPU on the motherboard of this blade.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.4ColumncaUcsCpuModelread-onlycurrentModel of the CPU.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.5ColumncaUcsCpuSerialNumberread-onlycurrentSerial Number of the CPU.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.6ColumncaUcsCpuVendorread-onlycurrentVendor of the CPU.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.7ColumncaUcsCpuRevisionread-onlycurrentRevision of the model of the CPU.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.8ColumncaUcsCpuTempread-onlycurrentCurrently available temperature readings from the CPU temp sensor.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.9ColumncaUcsCpuArchitectureread-onlycurrentProcessor architecture of this CPU, for example 'Xeon'.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.10ColumncaUcsCpuCoresread-onlycurrentNumber of cores in the CPU.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.11ColumncaUcsCpuSocketDesignationread-onlycurrentIdentifier of the socket this CPU is inserted into.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.12ColumncaUcsCpuSpeedread-onlycurrentEffective clock speed of the CPU in MHz.
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.13ColumncaUcsCpuSteppingread-onlycurrentCPU silicon revision (AMD calls it a revision as well; Intel calls it stepping information).
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.14ColumncaUcsCpuThreadread-onlycurrentCPU threads
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.15ColumncaUcsCpuProductNameread-onlycurrentProduct name of CPU
1.3.6.1.4.1.546.16.58.3.2.3.1.1.1.16ColumncaUcsCpuPidread-onlycurrentPid of CPU
1.3.6.1.4.1.546.16.58.3.2.3.2NodecaUcsBladeServerMotherboard
1.3.6.1.4.1.546.16.58.3.2.3.2.1TablecaUcsMotherboardTablenot-accessiblecurrentcaUcsBladeServerMotherboard table.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1RowcaUcsBladeServerMotherboardEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.1ColumncaUcsMotherboardUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.2ColumncaUcsMotherboardBladeIndexread-onlycurrentIndex of the blade for the caBladeTable.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.3ColumncaUcsMotherboardModelread-onlycurrentModel of the motherboard.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.4ColumncaUcsMotherboardSerialNumberread-onlycurrentSerial number of the motherboard.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.5ColumncaUcsMotherboardVendorread-onlycurrentVendor of the motherboard.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.6ColumncaUcsMotherboardRevisionread-onlycurrentRevision of the model of the motherboard.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.7ColumncaUcsMotherboardloSensorTempread-onlycurrentDegrees celsius.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.8ColumncaUcsMotherboardRearSensorTempread-onlycurrentDegrees celsius.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.9ColumncaUcsMotherboardConsumedPowerread-onlycurrentWattage being currently consumed by the motherboard.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.10ColumncaUcsMotherboard12vCurrentread-onlycurrentAmperage on the 12 volt motherboard input.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.11ColumncaUcsMotherboard12vVoltageread-onlycurrentVoltage on the 12 volt motherboard input.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.12ColumncaUcsMotherboardDdr3Line0Voltageread-onlycurrentVoltage to the memory banks in line 0.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.13ColumncaUcsMotherboardDdr3Line1Voltageread-onlycurrentVoltage to the memory banks in line 1.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.14ColumncaUcsMotherboardCpu0Voltageread-onlycurrentVoltage to the CPU in CPU slot 0.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.15ColumncaUcsMotherboardCpu1Voltageread-onlycurrentVoltage to the CPU in CPU slot 1.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.16ColumncaUcsMotherboardProductNameread-onlycurrentProduct name of the motherboard.
1.3.6.1.4.1.546.16.58.3.2.3.2.1.1.17ColumncaUcsMotherboardPidread-onlycurrentPid of the motherboard.
1.3.6.1.4.1.546.16.58.3.2.3.3NodecaUcsBladeServerMemory
1.3.6.1.4.1.546.16.58.3.2.3.3.1TablecaUcsMemoryArrayTablenot-accessiblecurrentUCS Memory Array table.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1RowcaUcsMemoryArrayEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.1ColumncaUcsMemoryArrayUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.2ColumncaUcsMemoryArrayBladeIndexread-onlycurrentCorresponds to caBladeIndes.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.3ColumncaUcsMemoryArrayIndexread-onlycurrentInstance of a memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.4ColumncaUcsMemoryArrayModelread-onlycurrentModel of a memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.5ColumncaUcsMemoryArraySerialNumberread-onlycurrentSerial number of the memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.6ColumncaUcsMemoryArrayVendorread-onlycurrentVendor of the memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.7ColumncaUcsMemoryArrayRevisionread-onlycurrentRevision of the model of the memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.8ColumncaUcsMemoryArrayMaxCapacityread-onlycurrentTotal MBs if all possible memory usable on this memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.9ColumncaUcsMemoryArrayMaxNumOfDimmsread-onlycurrentMaximum number of memory DIMMs on this memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.10ColumncaUcsMemoryArrayCpuIdread-onlycurrentCPU instance (on this blade) associated with this memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.11ColumncaUcsMemoryArrayNumOfDimmsread-onlycurrentCurrent number of installed DIMMs in the memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.12ColumncaUcsMemoryArrayCurrentCapacityread-onlycurrentTotal MBs of memory currently installed in the memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.13ColumncaUcsMemoryArrayErrorCorrectionread-onlycurrentThe type of error correction required by the memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.14ColumncaUcsMemoryArrayProductNameread-onlycurrentProduct name of the model of the memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.1.1.15ColumncaUcsMemoryArrayPidread-onlycurrentPid of the model of the memory array.
1.3.6.1.4.1.546.16.58.3.2.3.3.2TablecaUcsMemoryModuleTablenot-accessiblecurrentUCS Memory Array table.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1RowcaUcsMemoryModuleEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.1ColumncaUcsMemoryModuleUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.2ColumncaUcsMemoryModuleBladeIndexread-onlycurrentCorresponds to caBladeIndex.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.3ColumncaUcsMemoryModuleIndexread-onlycurrentInstance of a memory module.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.4ColumncaUcsMemoryModuleModelread-onlycurrentThe model of the memory module.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.5ColumncaUcsMemoryModuleSerialNumberread-onlycurrentThe serial number of the memory module.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.6ColumncaUcsMemoryModuleVendorread-onlycurrentVendor of the memory module.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.7ColumncaUcsMemoryModuleRevisionread-onlycurrentRevision of the model of the memory module.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.8ColumncaUcsMemoryModuleTyperead-onlycurrentThe form and specification adherence of the memory interface.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.9ColumncaUcsMemoryModuleLatencyread-onlycurrentNumber of clock cycles (synchronous DRAM) for the data to be available at a particular memory address.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.10ColumncaUcsMemoryModuleFormFactorread-onlycurrentThe type of memory (DIMM, SODIMM, etc.)
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.11ColumncaUcsMemoryModuleSpeedread-onlycurrentThe speed of the module.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.12ColumncaUcsMemoryModuleLocationread-onlycurrentWhich DIMM slot this memory is inserted into.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.13ColumncaUcsMemoryModuleWidthread-onlycurrentThe number of bits in a bank of memory.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.14ColumncaUcsMemoryModuleBankread-onlycurrentThe number of banks in this memory module.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.15ColumncaUcsMemoryModuleClockread-onlycurrentMHz
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.16ColumncaUcsMemoryModuleTempread-onlycurrentdegrees celsius
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.17ColumncaUcsMemoryModuleMemoryArrayIndexread-onlycurrentCorresponds to caMemoryArrayIndex; indicates to which memory array this memory unit belongs.
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.18ColumncaUcsMemoryModuleCapacityread-onlycurrentsize of the memory module in MBs
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.19ColumncaUcsMemoryModulePresenceread-onlycurrentPresence of DIMM
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.20ColumncaUcsMemoryModuleProductNameread-onlycurrentProduct name of DIMM
1.3.6.1.4.1.546.16.58.3.2.3.3.2.1.21ColumncaUcsMemoryModulePidread-onlycurrentPid of DIMM
1.3.6.1.4.1.546.16.58.3.2.3.4NodecaUcsBladeServerStorage
1.3.6.1.4.1.546.16.58.3.2.3.4.1TablecaUcsStorageTablenot-accessiblecurrentcaUcsBladeServerStorageController table.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1RowcaUcsStorageEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.1ColumncaUcsStorageUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.2ColumncaUcsStorageBladeIndexread-onlycurrentCorresponds to caBladeIndex.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.3ColumncaUcsStorageControllerIndexread-onlycurrentIndex of a storage controller on this blade.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.4ColumncaUcsStorageControllerModelread-onlycurrentModel of the storage controller.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.5ColumncaUcsStorageControllerSerialNumberread-onlycurrentSerial number of the storage controller.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.6ColumncaUcsStorageControllerVendorread-onlycurrentVendor of the storage controller.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.7ColumncaUcsStorageControllerRevisionread-onlycurrentRevision of the model of the storage controller.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.8ColumncaUcsStorageControllerTyperead-onlycurrentType of storage controller - only currently available value is 'SAS(1)'.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.9ColumncaUcsStorageControllerBootLoaderVersionread-onlycurrentVersion of the boot loader firmware that is running currently.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.10ColumncaUcsStorageControllerFirmwareVersionread-onlycurrentVersion of the storage controller firmware that is currently running.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.11ColumncaUcsStorageControllerStartupFirmwareVersionread-onlycurrentStartup version fo the storage controller firmware.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.12ColumncaUcsStorageControllerProductNameread-onlycurrentProduct name of the storage controller.
1.3.6.1.4.1.546.16.58.3.2.3.4.1.1.13ColumncaUcsStorageControllerPidread-onlycurrentPid of the storage controller.
1.3.6.1.4.1.546.16.58.3.2.3.4.2TablecaUcsStorageLocalDiskTablenot-accessiblecurrentcaUcsStorageLocalDisk table.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1RowcaUcsStorageLocalDiskEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.1ColumncaUcsStorageLocalDiskUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.2ColumncaUcsStorageLocalDiskBladeIndexread-onlycurrentCorresponds to caBladeIndex.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.3ColumncaUcsStorageLocalDiskIndexread-onlycurrentIndex of a local disk drive on this blade.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.4ColumncaUcsStorageLocalDiskModelread-onlycurrentModel of the disk drive.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.5ColumncaUcsStorageLocalDiskSerialNumberread-onlycurrentSerial number of the disk drive.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.6ColumncaUcsStorageLocalDiskVendorread-onlycurrentVendor of the disk drive.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.7ColumncaUcsStorageLocalDiskRevisionread-onlycurrentRevision of the model of the disk drive.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.8ColumncaUcsStorageLocalDiskNumBlocksread-onlycurrentTotal number of blocks on this drive.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.9ColumncaUcsStorageLocalDiskSizeread-onlycurrentSize in MBs of a block on this drive.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.10ColumncaUcsStorageLocalDiskBlockSizeread-onlycurrentSize in bytes of a block on this drive.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.11ColumncaUcsStorageLocalDiskFirmwareVersionread-onlycurrentVersion of the firmware that is currently running.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.12ColumncaUcsStorageLocalDiskControllerIndexread-onlycurrentCorresponds to caStorageControllerIndex.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.13ColumncaUcsStorageLocalDiskProductNameread-onlycurrentProduct name of the disk drive.
1.3.6.1.4.1.546.16.58.3.2.3.4.2.1.14ColumncaUcsStorageLocalDiskPidread-onlycurrentPid of the disk drive.
1.3.6.1.4.1.546.16.58.3.2.3.4.3TablecaUcsStorageLocalLunTablenot-accessiblecurrentcaUcsStorageLocalLun table.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1RowcaUcsStorageLocalLunEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.1ColumncaUcsStorageLocalLunUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.2ColumncaUcsStorageLocalLunBladeIndexread-onlycurrentCorresponds to caBladeIndex.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.3ColumncaUcsStorageLocalLunIndexread-onlycurrentInstance of a logical unit number (LUN) designation configured on the blade.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.4ColumncaUcsStorageLocalLunModelread-onlycurrentModel of the storage controller implementing this LUN.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.5ColumncaUcsStorageLocalLunSerialNumberread-onlycurrentSerial number of the storage controller implementing this LUN.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.6ColumncaUcsStorageLocalLunVendorread-onlycurrentVendor of the storage controller implementing this LUN.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.7ColumncaUcsStorageLocalLunRevisionread-onlycurrentRevision of the model of the storage controller implementing this LUN.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.8ColumncaUcsStorageLocalLunIdread-onlycurrentLogical identifier and numberical designation of this LUN.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.9ColumncaUcsStorageLocalLunNumBlocksread-onlycurrentTotal number of blocks in this partition addressed by this LUN..
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.10ColumncaUcsStorageLocalLunSizeread-onlycurrentNumber of MBs in the partition addressed by this LUN.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.11ColumncaUcsStorageLocalLunBlockSizeread-onlycurrentSize in bytes of a block in the partition addressed by this LUN.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.12ColumncaUcsStorageLocalLunTyperead-onlycurrentUnderlying format of the disk resource supplying this LUN.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.13ColumncaUcsStorageLocalLunControllerIndexread-onlycurrentCorresponds to caStorageControllerIndex.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.14ColumncaUcsStorageLocalLunProductNameread-onlycurrentProduct name of the storage controller implementing this LUN.
1.3.6.1.4.1.546.16.58.3.2.3.4.3.1.15ColumncaUcsStorageLocalLunPidread-onlycurrentPid of the storage controller implementing this LUN.
1.3.6.1.4.1.546.16.58.3.3NodecaUcsSwitchExt
1.3.6.1.4.1.546.16.58.3.3.1NodecaUcsSwitch
1.3.6.1.4.1.546.16.58.3.3.1.1TablecaUcsSwitchTablenot-accessiblecurrentUcsSwitch table.
1.3.6.1.4.1.546.16.58.3.3.1.1.1RowcaUcsSwitchEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.1ColumncaUcsSwitchUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.3.1.1.1.2ColumncaUcsSwitchIndexread-onlycurrentSame as caSwitchIndex.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.3ColumncaUcsSwitchInbandIfIpTyperead-onlycurrentIn-band management IP Address Type. This is an enumerated INTEGER of type InetAddressType and applies to the In-band IP, Mask, and Gateway addresses.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.4ColumncaUcsSwitchInbandIfIpread-onlycurrentIn-band management IP Address.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.5ColumncaUcsSwitchInbandIfMaskread-onlycurrentIn-band management IP Address mask.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.6ColumncaUcsSwitchInbandIfGatewayread-onlycurrentIn-band management gateway address for IP traffic.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.7ColumncaUcsSwitchInbandIfVnetread-onlycurrentIn-band management VLAN id.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.8ColumncaUcsSwitchOutOfBandIfIpTyperead-onlycurrentOut-of-band management IP Address Type. This is an enumerated INTEGER of type InetAddressType and applies to the Out-of-band IP, Mask, and Gateway addresses.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.9ColumncaUcsSwitchOutOfBandIfIpread-onlycurrentOut-of-band management IP address.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.10ColumncaUcsSwitchOutOfBandIfMaskread-onlycurrentOut-of-band management IP address mask.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.11ColumncaUcsSwitchOutOfBandIfGatewayread-onlycurrentOut-of-band management gateway address for IP traffic.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.12ColumncaUcsSwitchAdminInbandIfStateread-onlycurrentDetermining whether administrative communication to the switch can occur in-band.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.13ColumncaUcsSwitchEnvFanControllerInlet1read-onlycurrentTemperature in degrees celsius.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.14ColumncaUcsSwitchEnvFanControllerInlet2read-onlycurrentTemperature in degrees celsius.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.15ColumncaUcsSwitchEnvFanControllerInlet3read-onlycurrentTemperature in degrees celsius.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.16ColumncaUcsSwitchEnvFanControllerInlet4read-onlycurrentTemperature in degrees celsius.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.17ColumncaUcsSwitchEnvMainBoardOutlet1read-onlycurrentTemperature in degrees celsius.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.18ColumncaUcsSwitchEnvMainBoardOutlet2read-onlycurrentTemperature in degrees celsius.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.19ColumncaUcsSwitchEnvMezzBoardOutlet1read-onlycurrentTemperature in degrees celsius.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.20ColumncaUcsSwitchEnvMezzBoardOutlet2read-onlycurrentTemperature in degrees celsius.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.21ColumncaUcsSwitchCpuLoadread-onlycurrentCPU utilization over the last minute.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.22ColumncaUcsSwitchAvailableMemoryread-onlycurrentAvailable memory on the switch in MBs.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.23ColumncaUcsSwitchMemoryCacheSizeread-onlycurrentSize of the memory cache on the switch in MBs.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.24ColumncaUcsSwitchBootLoaderVersionread-onlycurrentVersion of the boot loader firmware that is running currently.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.25ColumncaUcsSwitchKernelVersionread-onlycurrentVersion of the kernel firmware that is currently running.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.26ColumncaUcsSwitchSystemVersionread-onlycurrentVersion of the system firmware taht is currently running.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.27ColumncaUcsSwitchStartupKernelVersionread-onlycurrentStartup version of the kernel firmware.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.28ColumncaUcsSwitchStartupSystemVersionread-onlycurrentStartup version of the system firmware.
1.3.6.1.4.1.546.16.58.3.3.1.1.1.29ColumncaUcsSwitchOperabilityread-onlycurrentOperability of the switch.
1.3.6.1.4.1.546.16.58.3.3.1.2ScalarcaUcsSwitchTableLastChangeread-onlycurrentLast table refresh time
1.3.6.1.4.1.546.16.58.3.3.2NodecaUcsSwitchFan
1.3.6.1.4.1.546.16.58.3.3.2.1TablecaUcsSwitchFanTablenot-accessiblecurrentcaUcsSwitchFan table.
1.3.6.1.4.1.546.16.58.3.3.2.1.1RowcaUcsSwitchFanEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.3.2.1.1.1ColumncaUcsSwitchFanUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.3.2.1.1.2ColumncaUcsSwitchFanSwitchIdread-onlycurrentSame as caSwitchIndex.
1.3.6.1.4.1.546.16.58.3.3.2.1.1.3ColumncaUcsSwitchFanIdread-onlycurrentId unique within the context of the switch; same as caSwitchFanIndex.
1.3.6.1.4.1.546.16.58.3.3.2.1.1.4ColumncaUcsSwitchFanOperStateread-onlycurrentOperational state of the switch fan.
1.3.6.1.4.1.546.16.58.3.3.2.1.1.5ColumncaUcsSwitchFanOperabilityread-onlycurrentOperability of the switch fan.
1.3.6.1.4.1.546.16.58.3.3.2.1.1.6ColumncaUcsSwitchFanPerformanceread-onlycurrentSwitch fan performance
1.3.6.1.4.1.546.16.58.3.3.2.1.1.7ColumncaUcsSwitchFanPowerread-onlycurrentSwitch fan power status
1.3.6.1.4.1.546.16.58.3.3.3NodecaUcsSwitchPower
1.3.6.1.4.1.546.16.58.3.3.3.1TablecaUcsSwitchPsuTablenot-accessiblecurrentcaUcsSwitchPsu table.
1.3.6.1.4.1.546.16.58.3.3.3.1.1RowcaUcsSwitchPsuEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.3.3.1.1.1ColumncaUcsSwitchPsuUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.3.3.1.1.2ColumncaUcsSwitchPsuSwitchIdread-onlycurrentSame as caSwitchIndex.
1.3.6.1.4.1.546.16.58.3.3.3.1.1.3ColumncaUcsSwitchPsuIdread-onlycurrentId unique within the context of the switch; same as caSwitchPsuIndex.
1.3.6.1.4.1.546.16.58.3.3.3.1.1.4ColumncaUcsSwitchPsuOperStateread-onlycurrentOperational state of the switch power supply unit.
1.3.6.1.4.1.546.16.58.3.3.3.1.1.5ColumncaUcsSwitchPsuOperabilityread-onlycurrentOperability of the switch power supply unit.
1.3.6.1.4.1.546.16.58.3.3.3.1.1.6ColumncaUcsSwitchPsuPerformanceread-onlycurrentSwitch Psu performance
1.3.6.1.4.1.546.16.58.3.3.3.1.1.7ColumncaUcsSwitchPsuPowerread-onlycurrentSwitch Psu power status
1.3.6.1.4.1.546.16.58.3.3.4NodecaUcsSwitchInterfaces
1.3.6.1.4.1.546.16.58.3.3.4.1TablecaUcsSwitchConnTablenot-accessiblecurrentcaUcsSwitchConn table.
1.3.6.1.4.1.546.16.58.3.3.4.1.1RowcaUcsSwitchConnEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.3.4.1.1.1ColumncaUcsSwitchConnUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.3.4.1.1.2ColumncaUcsSwitchConnSwitchIndexread-onlycurrentIndex of an interface on a switch; same value as caSwitchIndex.
1.3.6.1.4.1.546.16.58.3.3.4.1.1.3ColumncaUcsSwitchConnIfIndexread-onlycurrentIndex of an interface on a switch; same value as caSwitchIfIndex.
1.3.6.1.4.1.546.16.58.3.3.4.1.1.4ColumncaUcsSwitchConnChassisIdread-onlycurrentThe value of caChassisId that contains the fabric extender taht is connected to this switch port.
1.3.6.1.4.1.546.16.58.3.3.4.1.1.5ColumncaUcsSwitchConnFabricExtenderSlotIdread-onlycurrentThe value of caUcsFabricExtenderSlotId connected to this particular port or 0 if the port is not a backplane port.
1.3.6.1.4.1.546.16.58.3.3.4.1.1.6ColumncaUcsSwitchConnFabricExtenderPortIndexread-onlycurrentThe value of caUcsFabricExtenderPortIndex connected to this particular port or 0 if the port is not a backplane port.
1.3.6.1.4.1.546.16.58.3.3.4.2TablecaUcsSwitchIfEthStatsTablenot-accessiblecurrentcaUcsSwitchIfEthStats table.
1.3.6.1.4.1.546.16.58.3.3.4.2.1RowcaUcsSwitchIfEthStatsEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.1ColumncaUcsSwitchIfEthStatsUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.3.4.2.1.2ColumncaUcsSwitchIfEthStatsSwitchIndexread-onlycurrentIndex of the switch from the caSwitchTable.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.3ColumncaUcsSwitchIfEthStatsIndexread-onlycurrentIndex of an interface on a switch; corresponds to caSwitchIfIndex.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.4ColumncaUcsSwitchIfEthStatsAlignread-onlycurrentCount of a number of alignment errors.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.5ColumncaUcsSwitchIfEthStatsDefferedTxread-onlycurrentCount of a number of transmissions that were deferred.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.6ColumncaUcsSwitchIfEthStatsFcsread-onlycurrentCount of the number of frame check sequence errors.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.7ColumncaUcsSwitchIfEthStatsIntMacRxread-onlycurrentCount of the number of packets in error when received by the MAC layer.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.8ColumncaUcsSwitchIfEthStatsIntMacTxread-onlycurrentCount of the number of packets in error when the MAC layer attempts to transmit.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.9ColumncaUcsSwitchIfEthStatsOutDiscardread-onlycurrentCount of the number of packets discarded due to network congestion.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.10ColumncaUcsSwitchIfEthStatsRcvread-onlycurrentCount of the total number of received packets in error.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.11ColumncaUcsSwitchIfEthStatsUnderSizeread-onlycurrentCount of the total number of packets received under 64 bytes in length.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.12ColumncaUcsSwitchIfEthStatsXmitread-onlycurrentCount of the total number of transmission errors.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.13ColumncaUcsSwitchIfEthStatsSqeTestread-onlycurrentCount of the number of failed SQE tests.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.14ColumncaUcsSwitchIfEthStatsCarrierSenseread-onlycurrentCount of the number of carrier sense errors.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.15ColumncaUcsSwitchIfEthStatsExcessCollisionread-onlycurrentCount of the number of packets dropped due to excess collisions.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.16ColumncaUcsSwitchIfEthStatsGiantsread-onlycurrentCount of the number of packets dropped because they are larger than the largest allowed packet on the medium.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.17ColumncaUcsSwitchIfEthStatsLateCollisionread-onlycurrentCount of the number of packets lost due to a late collision.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.18ColumncaUcsSwitchIfEthStatsMultiCollisionread-onlycurrentCount of the number of packets lost due to multiple collisions.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.19ColumncaUcsSwitchIfEthStatsSingleCollisionread-onlycurrentCount of the number of packets lost due to a single collision.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.20ColumncaUcsSwitchIfEthStatsSymbolread-onlycurrentCount of the number of packets lost due to errors in encoding or decoding symbols.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.21ColumncaUcsSwitchIfEthStatsRecvPauseread-onlycurrentCount of the number or received 802.3x PAUSE packets.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.22ColumncaUcsSwitchIfEthStatsResetsread-onlycurrentCount of the number of 802.3x RESET packets.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.23ColumncaUcsSwitchIfEthStatsXmitPauseread-onlycurrentCount of the number of transmitted 802.3x PAUSE packets.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.24ColumncaUcsSwitchIfEthStatsRxJumboPacketsread-onlycurrentCount of the number of received jumbo packets.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.25ColumncaUcsSwitchIfEthStatsRxTotalPacketsread-onlycurrentCount of the total number of packets received.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.26ColumncaUcsSwitchIfEthStatsTxJumboPacketsread-onlycurrentCount of the number of transmitted jumbo packets.
1.3.6.1.4.1.546.16.58.3.3.4.2.1.27ColumncaUcsSwitchIfEthStatsTxTotalPacketsread-onlycurrentCount of the total number of transmitted packets.
1.3.6.1.4.1.546.16.58.3.3.4.3TablecaUcsSwitchIfFcStatsTablenot-accessiblecurrentcaUcsSwitchIfFcStats table.
1.3.6.1.4.1.546.16.58.3.3.4.3.1RowcaUcsSwitchIfFcStatsEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.3.4.3.1.1ColumncaUcsSwitchIfFcStatsUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.3.4.3.1.2ColumncaUcsSwitchIfFcStatsSwitchIndexread-onlycurrentIndex of the switch from the caSwitchTable; same value as caSwitchIndex.
1.3.6.1.4.1.546.16.58.3.3.4.3.1.3ColumncaUcsSwitchIfFcStatsIndexread-onlycurrentIndex of an interface on a switch; same value as caSwitchIfIndex.
1.3.6.1.4.1.546.16.58.3.3.4.3.1.4ColumncaUcsSwitchIfFcStatsCrcRxread-onlycurrentCount of the number of received fibre channel packets which failed their cyclical redundancy checks.
1.3.6.1.4.1.546.16.58.3.3.4.3.1.5ColumncaUcsSwitchIfFcStatsLinkFailuresread-onlycurrentCount of the number of fibre chennel errors that cause a link to fail.
1.3.6.1.4.1.546.16.58.3.3.4.3.1.6ColumncaUcsSwitchIfFcStatsRxread-onlycurrentCount of the number of errors that occurred while receiving fibre channel traffic.
1.3.6.1.4.1.546.16.58.3.3.4.3.1.7ColumncaUcsSwitchIfFcStatsSignalLossesread-onlycurrentCount of the number of signal losses that occurred on a fibre channel interface.
1.3.6.1.4.1.546.16.58.3.3.4.3.1.8ColumncaUcsSwitchIfFcStatsSyncLossesread-onlycurrentCount of the number of synchronization errors that occurred on a fibre channel interface.
1.3.6.1.4.1.546.16.58.3.3.4.3.1.9ColumncaUcsSwitchIfFcStatsTooLongRxread-onlycurrentCount of the number of frames received that were longer than their indicated length.
1.3.6.1.4.1.546.16.58.3.3.4.3.1.10ColumncaUcsSwitchIfFcStatsTooShortRxread-onlycurrentCount of the number of frames received that were shorter than their indicated length.
1.3.6.1.4.1.546.16.58.3.3.4.3.1.11ColumncaUcsSwitchIfFcStatsTxread-onlycurrentCount of the number of errors that occurred during transmission of fibre channel traffic.
1.3.6.1.4.1.546.16.58.3.4NodecaUcsManager
1.3.6.1.4.1.546.16.58.3.4.1TablecaUcsManagerTablenot-accessiblecurrentcaUcsManager table.
1.3.6.1.4.1.546.16.58.3.4.1.1RowcaUcsManagerEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.4.1.1.1ColumncaUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.4.1.1.2ColumncaUcsManagerIpAddressTyperead-onlycurrentIP address type of the UCS Manager. This is an enumerated INTEGER of type InetAddressType.
1.3.6.1.4.1.546.16.58.3.4.1.1.3ColumncaUcsManagerIpAddressread-onlycurrentIP address of the UCS Manager.
1.3.6.1.4.1.546.16.58.3.4.1.1.4ColumncaUcsManagerModeread-onlycurrentRunning mode of the UCS Manager.
1.3.6.1.4.1.546.16.58.3.4.1.1.5ColumncaUcsManagerNameread-onlycurrentName of the UCS Manager.
1.3.6.1.4.1.546.16.58.3.4.1.1.6ColumncaUcsManagerVersionread-onlycurrentVersion of the UCS Manager that is currently running.
1.3.6.1.4.1.546.16.58.3.4.1.1.7ColumncaUcsManagerStartupVersionread-onlycurrentStartup version of the UCS Manager.
1.3.6.1.4.1.546.16.58.3.4.1.1.8ColumncaUcsManagerSysUpTimeread-onlycurrentNumber of seconds the UCS Manager has been running.
1.3.6.1.4.1.546.16.58.3.4.1.1.9ColumncaUcsManagerConnectionStatusread-onlycurrentUCS manager connection status
1.3.6.1.4.1.546.16.58.3.4.2ScalarcaUcsManagerTableLastChangeread-onlycurrentLast table refresh time
1.3.6.1.4.1.546.16.58.3.5NodecaUcsServiceProfile
1.3.6.1.4.1.546.16.58.3.5.1TablecaUcsServiceProfileTablenot-accessiblecurrentcaUcsServiceProfile table.
1.3.6.1.4.1.546.16.58.3.5.1.1RowcaUcsServiceProfileEntrynot-accessiblecurrentThe table entry.
1.3.6.1.4.1.546.16.58.3.5.1.1.1ColumncaUcsServiceProfileUcsManagerIdread-onlycurrentUCS Manager id
1.3.6.1.4.1.546.16.58.3.5.1.1.2ColumncaUcsServiceProfileIntIdread-onlycurrentInternal Id of a service profile
1.3.6.1.4.1.546.16.58.3.5.1.1.3ColumncaUcsServiceProfileNameread-onlycurrentName of the Service Profile.
1.3.6.1.4.1.546.16.58.3.5.1.1.4ColumncaUcsServiceProfileDescriptionread-onlycurrentName of the Service Profile.
1.3.6.1.4.1.546.16.58.3.5.1.1.5ColumncaUcsServiceProfileBladeIndexread-onlycurrentIndex of a blade in a chassis for referencing caBladeTable and caUcsBladeTable. Note that this info won't be available if no blades are assigned to the service…
1.3.6.1.4.1.546.16.58.3.5.1.1.6ColumncaUcsServiceProfileBladeDnread-onlycurrentDn of the blade that is associated with the service profile. Note that this info won't be available if no blades are assigned to the service profile.
1.3.6.1.4.1.546.16.58.3.5.1.1.7ColumncaUcsServiceProfileBladeFullyQualifiedDnread-onlycurrentConcatenation of UCS Manager name with the Dn of the blade. Note that this info won't be available if no blades are assigned to the service profile.
1.3.6.1.4.1.546.16.58.3.5.1.1.8ColumncaUcsServiceProfileAssignedStateread-onlycurrentService profile assigned state
1.3.6.1.4.1.546.16.58.3.5.1.1.9ColumncaUcsServiceProfileAssociationStateread-onlycurrentService profile association state
1.3.6.1.4.1.546.16.58.3.5.1.1.10ColumncaUcsServiceProfileConfigStateread-onlycurrentService profile configuration state
1.3.6.1.4.1.546.16.58.3.5.1.1.11ColumncaUcsServiceProfileOperStateread-onlycurrentService profile operating state
1.3.6.1.4.1.546.16.58.3.5.1.1.12ColumncaUcsServiceProfileDnread-onlycurrentDn of the service profile.
1.3.6.1.4.1.546.16.58.3.5.1.1.13ColumncaUcsServiceProfileFullyQualifiedDnread-onlycurrentConcatenation of UCS Manager name with the Dn of the service profile.
1.3.6.1.4.1.546.16.58.3.5.1.1.14ColumncaUcsServiceProfileBladeOidread-onlycurrentReference blade index <UCS Manager Id>,<blade index> with full OID path
1.3.6.1.4.1.546.16.58.3.5.2ScalarcaUcsServiceProfileTableLastChangeread-onlycurrentLast table refresh time
Type Definitions
NameSyntaxStatusDescription
FloatInteger32currentThis data type represents a Float. 9456 represents 94.56%...
Uint64Counter64currentThis data type represents an unsigned 64 bit Limited to use in OBJECT-TYPE where the ACCESS clause is 'read-only' or 'accessible-for-notify'.