ERICSSON-ROUTER-STACKING-ALARM-MIB
23 objects
This MIB provides the possibility to report alarms according to the stacking requirements for fault management.
Imported Objects
| ERICSSON-ROUTER-SMI | eriRouterMgmt |
| IANA-ITU-ALARM-TC-MIB | IANAItuProbableCause |
| ITU-ALARM-TC-MIB | ItuPerceivedSeverity |
| SNMP-FRAMEWORK-MIB | SnmpAdminString |
| SNMPv2-CONF | MODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP |
| SNMPv2-SMI | MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE |
| SNMPv2-TC | DateAndTime DisplayString |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.193.218.2.117 | IdentityeriRouterStackingAlarmMib | This MIB provides the possibility to report alarms according to the stacking requirements for fault management. | ||
| 1.3.6.1.4.1.193.218.2.117.1 | NodeeriRouterStackingAlarmNotifications | |||
| 1.3.6.1.4.1.193.218.2.117.1.1 | NotificationeriRouterStackingIdMismatchAlarm | current | This notification is triggered when a stacking Id mismatch is found between connected chassis. | |
| 1.3.6.1.4.1.193.218.2.117.1.2 | NotificationeriRouterStackingChassisNumberMismatchAlarm | current | This notification is triggered when a chassis number mismatch is found. | |
| 1.3.6.1.4.1.193.218.2.117.1.3 | NotificationeriRouterStackingChassisNotFoundAlarm | current | This notification is triggered when a configured chassis is not found. | |
| 1.3.6.1.4.1.193.218.2.117.1.4 | NotificationeriRouterStackingChassisTypeMismatchAlarm | current | This notification is triggered when a chassis physically connected to the stack is not of a supported chassis type, or the chassis connected is not same as the… | |
| 1.3.6.1.4.1.193.218.2.117.1.5 | NotificationeriRouterStackingChassisUIDFormatMismatchAlarm | current | This notification is triggered when a chassis physically connected to the stack does not support the configured UID format. | |
| 1.3.6.1.4.1.193.218.2.117.1.6 | NotificationeriRouterStackingLicenseNotAvailableAlarm | current | This notification is triggered when a stacking license is missing or unavailable. | |
| 1.3.6.1.4.1.193.218.2.117.2 | NodeeriRouterStackingAlarmObjects | |||
| 1.3.6.1.4.1.193.218.2.117.2.1 | NodeeriRouterStackingAlarmNotify | |||
| 1.3.6.1.4.1.193.218.2.117.2.1.1 | ScalareriRouterStackingAlarmEventStackId | read-only | current | The value of this object contains the stack's identifier. |
| 1.3.6.1.4.1.193.218.2.117.2.1.2 | ScalareriRouterStackingAlarmEventChassisUID | read-only | current | The value of this object contains a chassis' UID. |
| 1.3.6.1.4.1.193.218.2.117.2.1.3 | ScalareriRouterStackingAlarmEventDateAndTime | read-only | current | The date and time when the event was raised. |
| 1.3.6.1.4.1.193.218.2.117.2.1.4 | ScalareriRouterStackingAlarmEventSeverity | read-only | current | The current severity of the event. |
| 1.3.6.1.4.1.193.218.2.117.2.1.5 | ScalareriRouterStackingAlarmEventProbableCause | read-only | current | The probable cause for this event. |
| 1.3.6.1.4.1.193.218.2.117.2.1.6 | ScalareriRouterStackingAlarmEventAdditionalText | read-only | current | The additional text of the event. |
| 1.3.6.1.4.1.193.218.2.117.2.1.7 | ScalareriRouterStackingAlarmEventMinorType | read-only | current | The minor type of the event. |
| 1.3.6.1.4.1.193.218.2.117.3 | NodeeriRouterStackingAlarmConformance | |||
| 1.3.6.1.4.1.193.218.2.117.3.1 | NodeeriRouterStackingAlarmCompliances | |||
| 1.3.6.1.4.1.193.218.2.117.3.1.1 | ComplianceeriRouterStackingAlarmCompliance | current | The compliance statement for SNMP entities which implement the STACKING ALARM MIB. | |
| 1.3.6.1.4.1.193.218.2.117.3.2 | NodeeriRouterStackingAlarmGroups | |||
| 1.3.6.1.4.1.193.218.2.117.3.2.1 | GrouperiRouterStackingAlarmNotifyObjectGroup | current | The collection of objects related to STACKING ALARM notifications. | |
| 1.3.6.1.4.1.193.218.2.117.3.2.2 | GrouperiRouterStackingAlarmNotifyGroup | current | Notification for tracking STACKING ALARM events. |