The management information definitions for the system resources management of a network device. This MIB is viewable under all contexts.
OIDNameAccessStatusDescription
1.3.6.1.4.1.193.218.2.24IdentityeriRouterSysResourcesMibThe management information definitions for the system resources management of a network device. This MIB is viewable under all contexts.
1.3.6.1.4.1.193.218.2.24.0NodeeriRouterSRMIBNotifications
1.3.6.1.4.1.193.218.2.24.0.1NotificationeriRouterSRProcessEventcurrentThis notification is sent each time the agent is informed of a process death/birth event.
1.3.6.1.4.1.193.218.2.24.0.2NotificationeriRouterSRSwitchoverEventcurrentThis notification identifies when a switchover occurs from one main processor module to a backup.
1.3.6.1.4.1.193.218.2.24.0.3NotificationeriRouterSRStorageFailedEventcurrentThis notification is sent when the value of eriRouterSRStorageStatus for a device changes to 'failed'.
1.3.6.1.4.1.193.218.2.24.0.4NotificationeriRouterSRPowerExceededEventcurrentThis notification identifies when a controller card is inserted and results in more power being drawn than recommended.
1.3.6.1.4.1.193.218.2.24.0.5NotificationeriRouterSseDiskHealthDegradedAlarmcurrentA eriRouterSseDiskHealthDegradedAlarm notification signifies that the hard disk health has degraded.
1.3.6.1.4.1.193.218.2.24.0.6NotificationeriRouterSseDiskFailedAlarmcurrentA eriRouterSseDiskFailedAlarm notification signifies that the hard disk has failed.
1.3.6.1.4.1.193.218.2.24.0.7NotificationeriRouterSseDiskMissingAlarmcurrentA eriRouterSseDiskMissingAlarm notification signifies that the hard disk is missing.
1.3.6.1.4.1.193.218.2.24.0.8NotificationeriRouterSseDiskUnsupportedAlarmcurrentA eriRouterSseDiskUnsupportedAlarm notification signifies that the hard disk is not supported.
1.3.6.1.4.1.193.218.2.24.0.9NotificationeriRouterSseDiskOOSAlarmcurrentA eriRouterSseDiskOOSAlarm notification signifies that the hard disk is out of service.
1.3.6.1.4.1.193.218.2.24.0.10NotificationeriRouterSseDiskVoltageFailureAlarmcurrentA eriRouterSseDiskVoltageFailureAlarm notification signifies that the hard disk voltage has failed.
1.3.6.1.4.1.193.218.2.24.0.11NotificationeriRouterSseDiskOverHeatAlarmcurrentA eriRouterSseDiskOverHeatAlarm notification signifies that the hard disk overheating.
1.3.6.1.4.1.193.218.2.24.0.12NotificationeriRouterSseDiskReadFailureAlarmcurrentA eriRouterSseDiskReadFailureAlarm notification signifies that the hard disk read failure.
1.3.6.1.4.1.193.218.2.24.0.13NotificationeriRouterIssuStateChangecurrentA notification reporting a change in ISSU state. The new state is returned in the notification.
1.3.6.1.4.1.193.218.2.24.0.14NotificationeriRouterChassisAlarmcurrentA eriRouterChassisAlarm notification signifies that an alarm has been raised/cleared on the chassis.
1.3.6.1.4.1.193.218.2.24.1NodeeriRouterSRMIBObjects
1.3.6.1.4.1.193.218.2.24.1.1NodeeriRouterSRProcess
1.3.6.1.4.1.193.218.2.24.1.1.1ScalareriRouterSRProcessNotifyLastUpdateread-onlycurrentThe value of sysUpTime when an entry in the eriRouterSRProcessNotifyTable was last added. Because this table is likely to contain many entries, polling of this…
1.3.6.1.4.1.193.218.2.24.1.1.2ScalareriRouterSRProcessEventNotifyEnableread-writecurrentIndicates whether eriRouterSRProcessEvent notification should be generated for this system.
1.3.6.1.4.1.193.218.2.24.1.1.3TableeriRouterSRProcessNotifyTablenot-accessiblecurrentA list of process event notifications since the agent was last re-initialized. If no process event has ever been generated, this table is empty, i.e., has zero…
1.3.6.1.4.1.193.218.2.24.1.1.3.1RoweriRouterSRProcessNotifyEntrynot-accessiblecurrentInformation about a death/birth process event notification which was last generated on the particular process.
1.3.6.1.4.1.193.218.2.24.1.1.3.1.1ColumneriRouterSRProcessNotifyProcNamenot-accessiblecurrentA human readable name identifying a particular process in the system.
1.3.6.1.4.1.193.218.2.24.1.1.3.1.2ColumneriRouterSRProcessNotifyPIDread-onlycurrentA decimal number uniquely identifies the process. The value 0 indicates the process has not been started.
1.3.6.1.4.1.193.218.2.24.1.1.3.1.3ColumneriRouterSRProcessNotifyEventCauseread-onlycurrentThis identifies the cause of a process death/birth event. The value firstStart(1) indicates the process has been started the first time. The other values ident…
1.3.6.1.4.1.193.218.2.24.1.1.3.1.4ColumneriRouterSRProcessNotifyEventTyperead-onlycurrentThe type of event notification sent on the process described by this row of the table. The process event type death(1) indicates that the agent has been inform…
1.3.6.1.4.1.193.218.2.24.1.1.3.1.5ColumneriRouterSRProcessNumOfSpawnread-onlycurrentThe number of times the process has been spawned since the system was last initialized. Note that this is different from the restart of the network management …
1.3.6.1.4.1.193.218.2.24.1.1.3.1.6ColumneriRouterSRProcessNotifyLastTimeSentread-onlycurrentThe value of sysUpTime at the time this notification was last generated on the process.
1.3.6.1.4.1.193.218.2.24.1.2NodeeriRouterSRStorage
1.3.6.1.4.1.193.218.2.24.1.2.1TableeriRouterSRStorageTablenot-accessiblecurrentThe (conceptual) table of long-term storage devices contained by the system. In particular, disk devices accessed remotely over a network are not included here.
1.3.6.1.4.1.193.218.2.24.1.2.1.1RoweriRouterSRStorageEntrynot-accessiblecurrentA (conceptual) entry for one long-term storage device contained by the system.
1.3.6.1.4.1.193.218.2.24.1.2.1.1.1ColumneriRouterSRStorageIndexnot-accessiblecurrentA unique value for each long-term storage device contained by the system. The value for each physical storage device must remain constant at least from one re-…
1.3.6.1.4.1.193.218.2.24.1.2.1.1.2ColumneriRouterSRStorageDescrread-onlycurrentA textual description of this storage device, optionally including the device's manufacturer, revision, and its serial number.
1.3.6.1.4.1.193.218.2.24.1.2.1.1.3ColumneriRouterSRStorageMediaread-onlycurrentAn indication of the type of media used in this long-term storage device.
1.3.6.1.4.1.193.218.2.24.1.2.1.1.4ColumneriRouterSRStorageRemovableread-onlycurrentDenotes whether or not the storage media may be removed from the drive/slot.
1.3.6.1.4.1.193.218.2.24.1.2.1.1.5ColumneriRouterSRStorageSizeread-onlycurrentThe total size for this long-term storage device. If the media is removable and is currently removed, this value should be zero.
1.3.6.1.4.1.193.218.2.24.1.2.1.1.6ColumneriRouterSRStorageUtilizationread-onlycurrentThis object is the percent utilization of the storage space on a scale of 0 to 100 percent. The formula used to calculate the Utilization is as follows. used b…
1.3.6.1.4.1.193.218.2.24.1.2.1.1.7ColumneriRouterSRStorageSlotread-onlycurrentThe chassis slot number in which the controller card containing this storage device is present.
1.3.6.1.4.1.193.218.2.24.1.2.1.1.8ColumneriRouterSRStorageMountTimeread-onlycurrentThe value of sysUpTime when this storage device was last mounted.
1.3.6.1.4.1.193.218.2.24.1.2.1.1.9ColumneriRouterSRStorageStatusread-onlycurrentThe functional status of this storage device.
1.3.6.1.4.1.193.218.2.24.1.2.1.1.10ColumneriRouterSRStorageErrorsread-onlycurrentThe cumulative count of soft errors on this storage device.
1.3.6.1.4.1.193.218.2.24.1.2.2TableeriRouterSseDiskStorageTablenot-accessiblecurrentFile Server System Blade is a card on the SmartEdge platform that manages data on hard disks connected to the card. This table provides details of these disks.
1.3.6.1.4.1.193.218.2.24.1.2.2.1RoweriRouterSseDiskStorageEntrynot-accessiblecurrentA entry for the disk on the SSE.
1.3.6.1.4.1.193.218.2.24.1.2.2.1.1ColumneriRouterSseDiskSlotnot-accessiblecurrentThe chassis slot number in which the disk resides.
1.3.6.1.4.1.193.218.2.24.1.2.2.1.2ColumneriRouterSseDiskNumnot-accessiblecurrentThe disk number used to identity the disk.
1.3.6.1.4.1.193.218.2.24.1.2.2.1.3ColumneriRouterSseDiskStateread-onlycurrentOperational status of the disk.
1.3.6.1.4.1.193.218.2.24.1.2.2.1.4ColumneriRouterSseDiskSizeread-onlycurrentTotal size of the disk in GBytes.
1.3.6.1.4.1.193.218.2.24.1.2.2.1.5ColumneriRouterSseDiskUsedread-onlycurrentTotal disk space utilized in GBytes.
1.3.6.1.4.1.193.218.2.24.1.3NodeeriRouterSRSystem
1.3.6.1.4.1.193.218.2.24.1.3.1ScalareriRouterSRSystemUptimeread-onlycurrentThe amount of time since this system was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the upti…
1.3.6.1.4.1.193.218.2.24.1.3.2ScalareriRouterSRSystemDateread-writecurrentThe host's notion of the local date and time of day.
1.3.6.1.4.1.193.218.2.24.1.4NodeeriRouterPowerExceeded
1.3.6.1.4.1.193.218.2.24.1.4.1ScalareriRouterSRPowerExceededStatusaccessible-for-notifycurrentThe status of alarm when a controller card is inserted and results in more power being drawn than recommended. If an instance of this object has the value norm…
1.3.6.1.4.1.193.218.2.24.1.5ScalareriRouterSseDiskAlarmDateAndTimeaccessible-for-notifycurrentThe local date and time when the alarm was raised
1.3.6.1.4.1.193.218.2.24.1.6ScalareriRouterSseDiskAlarmSeverityaccessible-for-notifycurrentThe perceived severity of the alarm.
1.3.6.1.4.1.193.218.2.24.1.7ScalareriRouterSseDiskAlarmProbableCauseaccessible-for-notifycurrentThe probable cause for this alarm.
1.3.6.1.4.1.193.218.2.24.1.8ScalareriRouterSseDiskEventTypeaccessible-for-notifycurrentThe type of the alarm.
1.3.6.1.4.1.193.218.2.24.1.9ScalareriRouterSseDiskAlarmDescriptionaccessible-for-notifycurrentA text string which conveys additional information about the alarm.
1.3.6.1.4.1.193.218.2.24.1.10NodeeriRouterIssuObjects
1.3.6.1.4.1.193.218.2.24.1.10.1ScalareriRouterIssuStateaccessible-for-notifycurrentThe current state of the inservice system upgrade (ISSU).
1.3.6.1.4.1.193.218.2.24.1.11NodeeriRouterChassisGroup
1.3.6.1.4.1.193.218.2.24.1.11.1ScalareriRouterChassisAlarmIdaccessible-for-notifycurrentThe chassis alarm identifier
1.3.6.1.4.1.193.218.2.24.1.11.2ScalareriRouterChassisAlarmTypeaccessible-for-notifycurrentThe chassis alarm type.
1.3.6.1.4.1.193.218.2.24.1.11.3ScalareriRouterChassisAlarmDateAndTimeaccessible-for-notifycurrentThe local date and time when the chassis alarm was raised
1.3.6.1.4.1.193.218.2.24.1.11.4ScalareriRouterChassisAlarmDescriptionaccessible-for-notifycurrentA text string which conveys additional information about the chassis alarm.
1.3.6.1.4.1.193.218.2.24.1.11.5ScalareriRouterChassisAlarmProbableCauseaccessible-for-notifycurrentThe probable cause for the chassis alarm.
1.3.6.1.4.1.193.218.2.24.1.11.6ScalareriRouterChassisAlarmSeverityaccessible-for-notifycurrentThe perceived severity of the chassis alarm.
1.3.6.1.4.1.193.218.2.24.2NodeeriRouterSRMIBConformance
1.3.6.1.4.1.193.218.2.24.2.1NodeeriRouterSRMIBCompliances
1.3.6.1.4.1.193.218.2.24.2.1.1ComplianceeriRouterSRMIBCompliance1read-onlyobsoleteThe requirements for conformance to the System Resources MIB. eriRouterSRMIBCompliance2 replaces this compliance.
1.3.6.1.4.1.193.218.2.24.2.1.2ComplianceeriRouterSRMIBCompliance2read-onlydeprecatedThe requirements for conformance to the System Resources MIB. eriRouterSRMIBCompliance3 replaces this compliance.
1.3.6.1.4.1.193.218.2.24.2.1.3ComplianceeriRouterSRMIBCompliance3read-onlydeprecatedThe requirements for conformance to the System Resources MIB.
1.3.6.1.4.1.193.218.2.24.2.1.4ComplianceeriRouterSRMIBCompliance4read-onlydeprecatedThe requirements for conformance to the System Resources MIB.
1.3.6.1.4.1.193.218.2.24.2.1.5ComplianceeriRouterSRMIBComplianceread-onlydeprecatedThe requirements for conformance to the System Resources MIB.
1.3.6.1.4.1.193.218.2.24.2.1.6ComplianceeriRouterSRMIBCompliance6read-onlycurrentThe requirements for conformance to the System Resources MIB.
1.3.6.1.4.1.193.218.2.24.2.2NodeeriRouterSRMIBGroups
1.3.6.1.4.1.193.218.2.24.2.2.1GrouperiRouterSRProcessNotifyGroupcurrentA collection of objects providing for remote monitoring of the system process event notification.
1.3.6.1.4.1.193.218.2.24.2.2.2GrouperiRouterSRStorageGroupdeprecatedThe System Resources Storage Group. Replaced by eriRouterSRStorageGroup2.
1.3.6.1.4.1.193.218.2.24.2.2.3GrouperiRouterSRProcessEventNotificationGroupobsoleteA collection of notifications that may be implemented for managing the system process. Replaced by eriRouterSRNotificationGroup.
1.3.6.1.4.1.193.218.2.24.2.2.4GrouperiRouterSRNotificationGroupdeprecatedA collection of notifications that are implemented for managing the system processes. Replaced by eriRouterSRNotificationGroup2.
1.3.6.1.4.1.193.218.2.24.2.2.5GrouperiRouterSRStorageGroup2currentThe System Resources Storage Group.
1.3.6.1.4.1.193.218.2.24.2.2.6GrouperiRouterSRNotificationGroup2currentA collection of notifications that may be implemented for managing the system resources.
1.3.6.1.4.1.193.218.2.24.2.2.7GrouperiRouterSRSystemGroupcurrentA collection of objects providing for remote monitoring of the system information.
1.3.6.1.4.1.193.218.2.24.2.2.8GrouperiRouterSRPowerNotifyGroupcurrentA notification that may be implemented for tracking power capacity exceeding limit.
1.3.6.1.4.1.193.218.2.24.2.2.9GrouperiRouterSRPowerExceededGroupcurrentA group providing for status of the power capacity exceeding limit.
1.3.6.1.4.1.193.218.2.24.2.2.10GrouperiRouterSseDiskGroupcurrentA group providing SSE disk details.
1.3.6.1.4.1.193.218.2.24.2.2.11GrouperiRouterSseDiskEventObjectGroupcurrentA collection of eriRouterSseDisk notification objects.
1.3.6.1.4.1.193.218.2.24.2.2.12GrouperiRouterSseDiskNotifyGroupcurrentNotifications that are implemented for SSE disks.
1.3.6.1.4.1.193.218.2.24.2.2.13GrouperiRouterIssuGroupcurrentA collection of ISSU notification objects.
1.3.6.1.4.1.193.218.2.24.2.2.14GrouperiRouterIssuNotifyGroupcurrentNotifications that are implemented for ISSU.
1.3.6.1.4.1.193.218.2.24.2.2.15GrouperiRouterChassisEventObjectGroupcurrentA collection of eriRouterChassis notification objects.