MIB Viewer

FDDI-CONCENTRATOR-MIB

50 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.22Nodefibronics
1.3.6.1.4.1.22.70NodefddiConcentrator
1.3.6.1.4.1.22.70.1NodeconcentratorPORT
1.3.6.1.4.1.22.70.1.1TableconcentratorPORTTablenot-accessiblemandatoryA list of PORT entries. The number of entries is given by the value of the snmpFddiPORTNumber (see standard fddi.
1.3.6.1.4.1.22.70.1.1.1RowconcentratorPORTEntrynot-accessiblemandatoryA PORT entry containing information common to a given PORT.
1.3.6.1.4.1.22.70.1.1.1.1ColumnconcentratorPORTSMTIndexread-onlymandatoryThe value of the SMT index associated with this PORT.
1.3.6.1.4.1.22.70.1.1.1.2ColumnconcentratorPORTIndexread-onlymandatoryA unique value for each PORT within a given SMT. Its value ranges between 1 and the sum of the values of concentratorSMTNonMasterCt { concentratorSMTEntry 6 } …
1.3.6.1.4.1.22.70.1.1.1.3ColumnconcentratorPORTTyperead-onlymandatoryThis value specifies the type of selected port
1.3.6.1.4.1.22.70.1.1.1.4ColumnconcentratorPORTStatusread-onlymandatoryThis value specifies the status of the selected port
1.3.6.1.4.1.22.70.2NodeconcentratorPROCESSOR
1.3.6.1.4.1.22.70.2.1ScalarconcentratorPROCESSORTyperead-onlymandatoryThis value specifies the type of processor
1.3.6.1.4.1.22.70.2.2ScalarconcentratorPROCESSORFrequencyread-onlymandatoryThis value specifies the frequency of the microprocessor (in MHz)
1.3.6.1.4.1.22.70.3NodeconcentratorMEMORY
1.3.6.1.4.1.22.70.3.1ScalarconcentratorSystemMEMORYAvailableread-onlymandatoryThis value specifies the amount of memory in kB
1.3.6.1.4.1.22.70.3.2ScalarconcentratorSystemMEMORYFreeread-onlymandatoryThis value specifies the available amount of free memory in kB
1.3.6.1.4.1.22.70.3.3ScalarconcentratorBufferMEMORYAvailableread-onlymandatoryThis value specifies the amount of memory in kB
1.3.6.1.4.1.22.70.3.4ScalarconcentratorMEMORYFlashEPROMread-onlymandatoryThis value specifies whether the flash EPROM is present or not
1.3.6.1.4.1.22.70.4NodeconcentratorSERIALPORT
1.3.6.1.4.1.22.70.4.1ScalarconcentratorSERIALPORTBaudRateread-writemandatoryThis value specifies the actual baud rate
1.3.6.1.4.1.22.70.4.2ScalarconcentratorSERIALPORTParityread-onlymandatoryThis value specifies the type of parity
1.3.6.1.4.1.22.70.4.3ScalarconcentratorSERIALPORTStopBitsread-onlymandatoryThis value specifies the number of stop bits
1.3.6.1.4.1.22.70.5NodeconcentratorVERSIONS
1.3.6.1.4.1.22.70.5.1ScalarconcentratorVERSIONSBoardSerialNumberread-onlymandatoryThis value specifies the serial number of the board
1.3.6.1.4.1.22.70.5.2ScalarconcentratorVERSIONSNMPread-onlymandatoryThis value specifies the actual SNMP version
1.3.6.1.4.1.22.70.5.3ScalarconcentratorVERSIONBIOSread-onlymandatoryThis value specifies the actual BIOS version
1.3.6.1.4.1.22.70.5.4ScalarconcentratorVERSIONSMTread-onlymandatoryThis value specifies the actual SMT version
1.3.6.1.4.1.22.70.5.5ScalarconcentratorVERSIONMACread-onlymandatoryThis value specifies the actual MAC version
1.3.6.1.4.1.22.70.5.6ScalarconcentratorVERSIONHRDWRread-onlymandatoryThis value specifies the actual version of the hardware
1.3.6.1.4.1.22.70.5.7ScalarconcentratorVERSIONSlotsNumberread-onlymandatoryThe number of slots in the concentrator.
1.3.6.1.4.1.22.70.5.8TableconcentratorVERSIONSlotsTablenot-accessiblemandatoryA list of slot entries. The number of entries is given by the value of the concentratorVERSIONSlotsNumber.
1.3.6.1.4.1.22.70.5.8.1RowconcentratorVERSIONSlotEntrynot-accessiblemandatoryAn entry containing information common to a given SLOT number.
1.3.6.1.4.1.22.70.5.8.1.1ColumnconcentratorVERSIONSlotIndexread-onlymandatoryThe value of the index associated with this particulary slot.
1.3.6.1.4.1.22.70.5.8.1.2ColumnconcentratorVERSIONSlotSerialNumberread-onlymandatoryThe serial number of this slot.
1.3.6.1.4.1.22.70.5.8.1.3ColumnconcentratorVERSIONSlotIdread-onlymandatoryThe identification number of this slot.
1.3.6.1.4.1.22.70.5.8.1.4ColumnconcentratorVERSIONSlotHrdwrStatusread-onlymandatoryThe value specifies the hardware state of the slot.
1.3.6.1.4.1.22.70.5.8.1.5ColumnconcentratorVERSIONSlotRevisionread-onlymandatoryRevision.
1.3.6.1.4.1.22.70.6NodeconcentratorPOWER
1.3.6.1.4.1.22.70.6.1ScalarconcentratorPOWERFirstSupplyStateread-onlymandatoryThis value specifies the state of the first power supply
1.3.6.1.4.1.22.70.6.2ScalarconcentratorPOWERSecondSupplyStateread-onlymandatoryThis value specifies the state of the second power supply
1.3.6.1.4.1.22.70.6.3ScalarconcentratorPOWERFirstFANStateread-onlymandatoryThis value specifies the state of the first fan
1.3.6.1.4.1.22.70.6.4ScalarconcentratorPOWERSecondFANStateread-onlymandatoryThis value specifies the state of the second power supply
1.3.6.1.4.1.22.70.6.5ScalarconcentratorPOWERTemperatureread-onlymandatoryThis value specifies the concentrator's temperature (in degrees Celsius)
1.3.6.1.4.1.22.70.6.6ScalarconcentratorPOWERBatteryStatusread-onlymandatoryThis value specifies the state of the battery
1.3.6.1.4.1.22.70.7NodeconcentratorTRAPS
1.3.6.1.4.1.22.70.7.1ScalarconcentratorMgrAddressread-writemandatoryBy means of this variable an SNMP manager can put or remove its own address into or out of the internal array of the manager's addresses to where the agent sen…
1.3.6.1.4.1.22.70.8NodeconcentratorIDENTIFIER
1.3.6.1.4.1.22.70.9NodeconcentratorTRAFFIC
1.3.6.1.4.1.22.70.9.1ScalarconcentratorTRAFFICSMTTransmitsread-onlymandatoryThis value specifies transmitted SMT frames
1.3.6.1.4.1.22.70.9.2ScalarconcentratorTRAFFICSMTReceivsread-onlymandatoryThis value specifies the recieved SMT frames
1.3.6.1.4.1.22.70.9.3ScalarconcentratorTRAFFICRS232Activityread-onlymandatoryThis value specifies whether the RS 232 is currently active