MIB Viewer

FIBRE-CHANNEL-MGMT-MIB

195 objects
The fibre channel management MIB module.
Imported Objects
SNMP-FRAMEWORK-MIBSnmpAdminString
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMICounter64 Integer32 IpAddress mib-2 MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE TimeTicks Unsigned32
SNMPv2-TCDisplayString RowStatus TEXTUAL-CONVENTION
OIDNameAccessStatusDescription
1.3.6.1.2.1.8888IdentityfcMgmtMIBThe fibre channel management MIB module.
1.3.6.1.2.1.8888.0NodefcMgmtNotifications
1.3.6.1.2.1.8888.0.1NotificationfcConnUnitStatusChangecurrentThe overall status of the connectivity unit has changed. Recommended severity level (for filtering): alert
1.3.6.1.2.1.8888.0.2NotificationfcConnUnitDeletedTrapcurrentAn fcConnUnit has been deleted from this agent. Recommended severity level (for filtering): warning
1.3.6.1.2.1.8888.0.3NotificationfcConnUnitEventTrapcurrentAn event has been generated by the connectivity unit. Recommended severity level (for filtering): info
1.3.6.1.2.1.8888.0.4NotificationfcConnUnitSensorStatusChangecurrentThe overall status of the connectivity unit has changed. Recommended severity level (for filtering): alert
1.3.6.1.2.1.8888.0.5NotificationfcConnUnitPortStatusChangecurrentThe overall status of the connectivity unit has changed. Recommended severity level (for filtering): alert
1.3.6.1.2.1.8888.1NodefcMgmtObjects
1.3.6.1.2.1.8888.1.1NodefcMgmtConfig
1.3.6.1.2.1.8888.1.1.1ScalarfcConnUnitNumberread-onlycurrentThe number of connectivity units present on this system. May be a count of the boards in a chassis or the number of full boxes in a rack.
1.3.6.1.2.1.8888.1.1.2ScalarfcConnURLread-onlycurrentThe top-level URL of the system. If it does not exist the value is an empty string. The URL format is implementation dependent and can have keywords embedded t…
1.3.6.1.2.1.8888.1.1.3TablefcConnUnitTablenot-accessiblecurrentThe connectivity table contains general information on the system's units. The number of entries is given by the value of fcConnUnitNumber. It is 1 for stand-a…
1.3.6.1.2.1.8888.1.1.3.1RowfcConnUnitEntrynot-accessiblecurrentA connectivity unit entry containing objects for a particular unit.
1.3.6.1.2.1.8888.1.1.3.1.1ColumnfcConnUnitIdread-onlycurrentThe unique identification for this connectivity unit among those within this proxy domain. The value MUST be unique within the proxy domain because it is the i…
1.3.6.1.2.1.8888.1.1.3.1.2ColumnfcConnUnitGlobalIdread-onlycurrentAn optional global-scope identifier for this connectivity unit. It MUST be a WWN for this connectivity unit or 16 octets of value zero. WWN formats requiring f…
1.3.6.1.2.1.8888.1.1.3.1.3ColumnfcConnUnitTyperead-onlycurrentThe type of this connectivity unit.
1.3.6.1.2.1.8888.1.1.3.1.4ColumnfcConnUnitNumPortsread-onlycurrentThe number of physical ports in the connectivity unit (internal/embedded, external).
1.3.6.1.2.1.8888.1.1.3.1.5ColumnfcConnUnitNumLinksread-onlycurrentThe number of links in the link table.
1.3.6.1.2.1.8888.1.1.3.1.6ColumnfcConnUnitStateread-onlycurrentThis object reports the overall state of the connectivity unit. The meaning of all values is essentially self-explanatory. Any of these values may occur with a…
1.3.6.1.2.1.8888.1.1.3.1.7ColumnfcConnUnitStatusread-onlycurrentThis object reports the overall status of the connectivity unit. The warning (4) value means that the connectivity unit needs attention; all other values are e…
1.3.6.1.2.1.8888.1.1.3.1.8ColumnfcConnUnitProductread-onlycurrentThe connectivity unit vendor's product model name.
1.3.6.1.2.1.8888.1.1.3.1.9ColumnfcConnUnitSerialNoread-onlycurrentThe serial number identification for this connectivity unit.
1.3.6.1.2.1.8888.1.1.3.1.10ColumnfcConnUnitUpTimeread-onlycurrentThe number of centiseconds since the last unit initialization.
1.3.6.1.2.1.8888.1.1.3.1.11ColumnfcConnUnitUrlread-onlycurrentURL to launch a management application, if applicable. Otherwise empty string. In a standalone unit, this would be the same as the top-level URL. This has the …
1.3.6.1.2.1.8888.1.1.3.1.12ColumnfcConnUnitDomainIdread-onlycurrent24 bit Fibre Channel address ID of this connectivity unit. Following the fibre channel standard, the right-most bit of the right-most octet is for the least si…
1.3.6.1.2.1.8888.1.1.3.1.13ColumnfcConnUnitProxyMasterread-onlycurrentA value of 'yes' means this is the proxy master unit for a set of managed units. For example, this could be the only unit with a management card in it for a se…
1.3.6.1.2.1.8888.1.1.3.1.14ColumnfcConnUnitPrincipalread-onlycurrentWhether this connectivity unit is the principal unit within the group of fabric elements. If this value is not applicable, return unknown.
1.3.6.1.2.1.8888.1.1.3.1.15ColumnfcConnUnitNumSensorsread-onlycurrentNumber of sensors in the fcConnUnitSensorTable.
1.3.6.1.2.1.8888.1.1.3.1.16ColumnfcConnUnitNumRevsread-onlycurrentThe number of revisions in the fcConnUnitRevsTable.
1.3.6.1.2.1.8888.1.1.3.1.17ColumnfcConnUnitModuleIdread-onlycurrentThis is a unique id, persistent between boots, that can be used to group a set of connectivity units together into a module. The intended use would be to creat…
1.3.6.1.2.1.8888.1.1.3.1.18ColumnfcConnUnitNameread-writecurrentA name for this connectivity unit. This object value should be persistent between boots.
1.3.6.1.2.1.8888.1.1.3.1.19ColumnfcConnUnitInforead-writecurrentInformation about this connectivity unit. This object value should be persistent between boots.
1.3.6.1.2.1.8888.1.1.3.1.20ColumnfcConnUnitControlread-writecurrentThis object is used to control the addressed connectivity unit. NOTE: 'ColdStart' and 'WarmStart' are as defined in mib-2 and are not meant to be a factory res…
1.3.6.1.2.1.8888.1.1.3.1.21ColumnfcConnUnitContactread-writecurrentContact information for this connectivity unit. The contact information is intended to facilitate contacting someone in case of problems, questions, etc. (e.g.…
1.3.6.1.2.1.8888.1.1.3.1.22ColumnfcConnUnitLocationread-writecurrentLocation information for this connectivity unit.
1.3.6.1.2.1.8888.1.1.3.1.23ColumnfcConnUnitEventFilterread-writecurrentThis value defines the event severity that will be logged by this connectivity unit. All events of severity less than or equal to fcConnUnitEventFilter are log…
1.3.6.1.2.1.8888.1.1.3.1.24ColumnfcConnUnitNumEventsread-onlycurrentNumber of events currently in the fcConnUnitEventTable.
1.3.6.1.2.1.8888.1.1.3.1.25ColumnfcConnUnitMaxEventsread-onlycurrentMax number of events that can be recorded at any one time in the fcConnUnitEventTable.
1.3.6.1.2.1.8888.1.1.3.1.26ColumnfcConnUnitEventCurrIDread-onlycurrentThe last used event ID (fcConnUnitEventId) recorded in the fcConnUnitEventTable. When no events are presently recorded in the fcConnUnitEventTable, the value o…
1.3.6.1.2.1.8888.1.1.3.1.27ColumnfcConnUnitFabricIDread-onlycurrentA globally unique value to identify the fabric that this ConnUnit belongs to, otherwise empty string. This would typically be equal to the connUnitGlobalID of …
1.3.6.1.2.1.8888.1.1.4TablefcConnUnitRevsTablenot-accessiblecurrentTable of the revisions of components (e.g., firmware, hardware, etc.) supported by the connectivity units managed by this agent.
1.3.6.1.2.1.8888.1.1.4.1RowfcConnUnitRevsEntrynot-accessiblecurrentA row in the fcConnUnitRevsTable.
1.3.6.1.2.1.8888.1.1.4.1.1ColumnfcConnUnitRevsIndexread-onlycurrentA unique value among all fcConnUnitRevsEntrys with the same value of fcConnUnitId, in the range between 1 and fcConnUnitNumRevs[fcConnUnitId].
1.3.6.1.2.1.8888.1.1.4.1.2ColumnfcConnUnitRevsRevisionread-onlycurrentA vendor-specific value identifying a revision of a component of the connectivity unit.
1.3.6.1.2.1.8888.1.1.4.1.3ColumnfcConnUnitRevsDescriptionread-onlycurrentDescription of a component in the ConnUnit to which the revision corresponds.
1.3.6.1.2.1.8888.1.1.5TablefcConnUnitSensorTablenot-accessiblecurrentTable of the sensors supported by each connectivity unit.
1.3.6.1.2.1.8888.1.1.5.1RowfcConnUnitSensorEntrynot-accessiblecurrentEach entry contains the information for a specific sensor.
1.3.6.1.2.1.8888.1.1.5.1.1ColumnfcConnUnitSensorIndexread-onlycurrentA unique value among all fcConnUnitSensorEntrys with the same value of fcConnUnitId, in the range between 1 and fcConnUnitNumSensors[fcConnUnitId].
1.3.6.1.2.1.8888.1.1.5.1.2ColumnfcConnUnitSensorNameread-onlycurrentA textual identification of the sensor intended primarily for operator use.
1.3.6.1.2.1.8888.1.1.5.1.3ColumnfcConnUnitSensorStatusread-onlycurrentThe status indicated by the sensor. unknown (1) = the unit cannot determine the status other (2) = the status does not fit any of the remaining values ok (3) =…
1.3.6.1.2.1.8888.1.1.5.1.4ColumnfcConnUnitSensorInforead-onlycurrentMiscellaneous static information about the sensor such as its serial number.
1.3.6.1.2.1.8888.1.1.5.1.5ColumnfcConnUnitSensorMessageread-onlycurrentThis describes the status of the sensor as a message. It may also provide more resolution on the sensor indication, for example 'Cover temperature 1503K, above…
1.3.6.1.2.1.8888.1.1.5.1.6ColumnfcConnUnitSensorTyperead-onlycurrentThe type of component being monitored by this sensor. The unknown (1) and other (2) values meanings analogous to those for the fcConnUnitSensorStatus object; a…
1.3.6.1.2.1.8888.1.1.5.1.7ColumnfcConnUnitSensorCharacteristicread-onlycurrentThe characteristics being monitored by this sensor. The unknown (1) and other (2) values meanings analogous to those for the fcConnUnitSensorStatus object; emf…
1.3.6.1.2.1.8888.1.1.6TablefcConnUnitPortTablenot-accessiblecurrentGeneric information on ports for a specific connectivity unit.
1.3.6.1.2.1.8888.1.1.6.1RowfcConnUnitPortEntrynot-accessiblecurrentEach entry contains the information for a specific port.
1.3.6.1.2.1.8888.1.1.6.1.1ColumnfcConnUnitPortIndexread-onlycurrentA unique value among all fcConnUnitPortEntrys on this connectivity unit, between 1 and fcConnUnitNumPorts.
1.3.6.1.2.1.8888.1.1.6.1.2ColumnfcConnUnitPortTyperead-onlycurrentThe port type refers to the protocol active on the port and can take one of the following values: unknown (1) - cannot be determined other (2) - none of the fo…
1.3.6.1.2.1.8888.1.1.6.1.3ColumnfcConnUnitPortFCClassCapread-onlycurrentBit mask that specifies the classes of service capability of this port. If this object is not applicable, the agent MUST return all bits set to zero.
1.3.6.1.2.1.8888.1.1.6.1.4ColumnfcConnUnitPortFCClassOpread-onlycurrentBit mask that specifies the classes of service that are currently operational at this port. If this object is not applicable, the agent MUST return all bits se…
1.3.6.1.2.1.8888.1.1.6.1.5ColumnfcConnUnitPortStateread-onlycurrentThe current state of the port hardware. The bypassed value (4) means that the port is online but is currently being isolated from the loop or fabric for some r…
1.3.6.1.2.1.8888.1.1.6.1.6ColumnfcConnUnitPortStatusread-onlycurrentThe current overall protocol status for the port. The warning value (4) means that the port needs attention; the notParticipating value (6) means that protocol…
1.3.6.1.2.1.8888.1.1.6.1.7ColumnfcConnUnitPortTransmitterTyperead-onlycurrentThe technology of the port transceiver.
1.3.6.1.2.1.8888.1.1.6.1.8ColumnfcConnUnitPortModuleTyperead-onlycurrentThe module type of the port connector. This object refers to the hardware implementation of the port. The embedded value (4) means 'fixed' (e.g., oneXnine).
1.3.6.1.2.1.8888.1.1.6.1.9ColumnfcConnUnitPortWwnread-onlycurrentThe World Wide Name of the port if applicable, otherwise empty string.
1.3.6.1.2.1.8888.1.1.6.1.10ColumnfcConnUnitPortFCIdread-onlycurrentThis is the assigned Fibre Channel ID of this port. This value is expected to be a Big Endian value of 24 bits. If this is loop, then it is the ALPA that is co…
1.3.6.1.2.1.8888.1.1.6.1.11ColumnfcConnUnitPortSerialNoread-onlycurrentThe serial number identification of the unit (e.g., for a GBIC). If this is not applicable, return a zero-length string.
1.3.6.1.2.1.8888.1.1.6.1.12ColumnfcConnUnitPortRevisionread-onlycurrentThe port revision (e.g., for a GBIC).
1.3.6.1.2.1.8888.1.1.6.1.13ColumnfcConnUnitPortVendorread-onlycurrentThe port vendor (e.g., for a GBIC).
1.3.6.1.2.1.8888.1.1.6.1.14ColumnfcConnUnitPortSpeedread-onlycurrentThe speed of the port in kilobytes per second.
1.3.6.1.2.1.8888.1.1.6.1.15ColumnfcConnUnitPortControlread-writecurrentThis object is used to control the addressed fcConnUnit's port. Valid commands are: unknown and invalid are only used as values that are read. resetConnUnitPor…
1.3.6.1.2.1.8888.1.1.6.1.16ColumnfcConnUnitPortNameread-writecurrentA string describing the addressed port.
1.3.6.1.2.1.8888.1.1.6.1.17ColumnfcConnUnitPortPhysicalNumberread-onlycurrentThis is the internal port number this port is known by. In many implementations, this should be the same as fcConnUnitPortIndex. Some implementations may have …
1.3.6.1.2.1.8888.1.1.6.1.18ColumnfcConnUnitPortProtocolCapread-onlycurrentBit mask that specifies the driver level protocol capability of this port. If this is not applicable, return all bits set to zero. The bits have the following …
1.3.6.1.2.1.8888.1.1.6.1.19ColumnfcConnUnitPortProtocolOpread-onlycurrentBit mask that specifies the driver level protocol(s) that are currently operational. If this is not applicable, return all bits set to zero. This object has th…
1.3.6.1.2.1.8888.1.1.6.1.20ColumnfcConnUnitPortNodeWwnread-onlycurrentThe Node World Wide Name of the port if applicable, otherwise all zeros. This should have the same value for a group of related ports. The container is defined…
1.3.6.1.2.1.8888.1.1.6.1.21ColumnfcConnUnitPortHWStateread-onlycurrentThe hardware detected state of the port.
1.3.6.1.2.1.8888.1.1.7TablefcConnUnitEventTablenot-accessiblecurrentThe table of connectivity unit events. Errors, warnings, and information should be reported in this table.
1.3.6.1.2.1.8888.1.1.7.1RowfcConnUnitEventEntrynot-accessiblecurrentEach entry contains information on a specific event for the given connectivity unit.
1.3.6.1.2.1.8888.1.1.7.1.1ColumnfcConnUnitEventIndexread-onlycurrentEach connectivity unit has its own event buffer. As it wraps, it may write over previous events. This object is an index into the buffer. It is recommended tha…
1.3.6.1.2.1.8888.1.1.7.1.2ColumnfcConnUnitREventTimeread-onlycurrentThis is the real time when the event occurred. It has the following format. DDMMYYYY HHMMSS DD=day number MM=month number YYYY=year number HH=hour number MM=mi…
1.3.6.1.2.1.8888.1.1.7.1.3ColumnfcConnUnitSEventTimeread-onlycurrentThis is the sysuptime timestamp when the event occurred.
1.3.6.1.2.1.8888.1.1.7.1.4ColumnfcConnUnitEventSeverityread-onlycurrentThe event severity level.
1.3.6.1.2.1.8888.1.1.7.1.5ColumnfcConnUnitEventTyperead-onlycurrentThe type of this event.
1.3.6.1.2.1.8888.1.1.7.1.6ColumnfcConnUnitEventObjectread-onlycurrentThis is used with the fcConnUnitEventType to identify which object the event refers to. It can be the OID of a connectivity unit or of another object like fcCo…
1.3.6.1.2.1.8888.1.1.7.1.7ColumnfcConnUnitEventDescrread-onlycurrentThe description of the event.
1.3.6.1.2.1.8888.1.1.8TablefcConnUnitLinkTablenot-accessiblecurrentA list of links know to this agent from this connectivity unit to other connectivity units.
1.3.6.1.2.1.8888.1.1.8.1RowfcConnUnitLinkEntrynot-accessiblecurrentAn entry describing a particular link to another.
1.3.6.1.2.1.8888.1.1.8.1.1ColumnfcConnUnitLinkIndexread-onlycurrentThis value is used to create a unique value for each entry in the link table with the same fcConnUnitId. The value can only be reused if it is not currently in…
1.3.6.1.2.1.8888.1.1.8.1.2ColumnfcConnUnitLinkNodeIdXread-onlycurrentThe node WWN of the unit at one end of the link. If the node WWN is unknown and the node is an fcConnUnit in the responding agent then the value of this object…
1.3.6.1.2.1.8888.1.1.8.1.3ColumnfcConnUnitLinkPortNumberXread-onlycurrentThe port number on the unit specified by fcConnUnitLinkNodeIdX if known, otherwise -1. If the value is non-negative then it will be equal to fcConnUnitPortPhys…
1.3.6.1.2.1.8888.1.1.8.1.4ColumnfcConnUnitLinkPortWwnXread-onlycurrentThe port WWN of the unit specified by fcConnUnitLinkNodeIdX if known, otherwise 16 octets of binary 0.
1.3.6.1.2.1.8888.1.1.8.1.5ColumnfcConnUnitLinkNodeIdYread-onlycurrentThe node WWN of the unit at the other end of the link. If the node WWN is unknown and the node is an fcConnUnit in the responding agent, then the value of this…
1.3.6.1.2.1.8888.1.1.8.1.6ColumnfcConnUnitLinkPortNumberYread-onlycurrentThe port number on the unit specified by fcConnUnitLinkNodeIdY if known, otherwise -1. If the value is non-negative then it will be equal to fcConnUnitPortPhys…
1.3.6.1.2.1.8888.1.1.8.1.7ColumnfcConnUnitLinkPortWwnYread-onlycurrentThe port WWN on the unit specified by fcConnUnitLinkNodeIdY if known, otherwise 16 octets of binary 0.
1.3.6.1.2.1.8888.1.1.8.1.8ColumnfcConnUnitLinkAgentAddressYread-onlycurrentThe address of an FCMGMT MIB agent for the node identified by fcConnUnitLinkNodeIdY, if known; otherwise 16 octets of binary 0.
1.3.6.1.2.1.8888.1.1.8.1.9ColumnfcConnUnitLinkAgentAddressTypeYread-onlycurrentIf fcConnUnitLinkAgentAddressY is non-zero, then it is a protocol address. fcConnUnitLinkAgentAddressTypeY is the the 'address family number' assigned by IANA …
1.3.6.1.2.1.8888.1.1.8.1.10ColumnfcConnUnitLinkAgentMaskread-onlycurrentThe mask to use for the address specified.
1.3.6.1.2.1.8888.1.1.8.1.11ColumnfcConnUnitLinkAgentPortYread-onlycurrentThe IP port number for the agent. This is provided in case the agent is at a non-standard SNMP port.
1.3.6.1.2.1.8888.1.1.8.1.12ColumnfcConnUnitLinkUnitTypeYread-onlycurrentType of the FC connectivity unit as defined in fcConnUnitType.
1.3.6.1.2.1.8888.1.1.8.1.13ColumnfcConnUnitLinkConnIdYread-onlycurrentThis is the Fibre Channel ID of this port. If the connectivity unit is a switch, this is expected to be a 24-bit Big Endian value. If this is loop, then it is …
1.3.6.1.2.1.8888.1.1.9ScalarfcConnUnitSnsMaxRowsread-onlycurrentThe maximum number of rows in the fcConnUnitSnsTable table.
1.3.6.1.2.1.8888.1.2NodefcMgmtNotifyFilter
1.3.6.1.2.1.8888.1.2.1ScalarfcTrapMaxClientsread-onlycurrentThe maximum number of SNMP trap recipients supported by the connectivity unit.
1.3.6.1.2.1.8888.1.2.2ScalarfcTrapClientCountread-onlycurrentThe current number of rows in the trap table.
1.3.6.1.2.1.8888.1.2.3TablefcTrapRegTablenot-accessiblecurrentA table containing a row for each IP address/port number that traps will be sent to.
1.3.6.1.2.1.8888.1.2.3.1RowfcTrapRegEntrynot-accessiblecurrentIp/Port pair for a specific client.
1.3.6.1.2.1.8888.1.2.3.1.1ColumnfcTrapRegIpAddressread-createcurrentThe Ip address of a client registered for traps.
1.3.6.1.2.1.8888.1.2.3.1.2ColumnfcTrapRegPortread-createcurrentThe UDP port to send traps to for this host. Normally this would be the standard trap port (UDP/162).
1.3.6.1.2.1.8888.1.2.3.1.3ColumnfcTrapRegFilterread-createcurrentThis value defines the trap severity filter for this trap host. The fcConnUnit will send to the designated target entity traps that have a severity level less …
1.3.6.1.2.1.8888.1.2.3.1.4ColumnfcTrapRegRowStateread-createcurrentSpecifies the operational status of the row. A RowStatus object may take any of six defined values: - active: traps may be sent as specified in this row; a man…
1.3.6.1.2.1.8888.1.3NodefcMgmtStatistics
1.3.6.1.2.1.8888.1.3.1TablefcConnUnitPortStatTablenot-accessiblecurrentA list of statistics for the ports.
1.3.6.1.2.1.8888.1.3.1.1RowfcConnUnitPortStatEntrynot-accessiblecurrentAn entry describing port statistics.
1.3.6.1.2.1.8888.1.3.1.1.1ColumnfcConnUnitPortStatIndexread-onlycurrentA unique value among all entrys in this table, between 0 and fcConnUnitNumPort[fcConnUnitPortUnitId].
1.3.6.1.2.1.8888.1.3.1.1.2ColumnfcConnUnitPortStatErrsread-onlycurrentA count of the errors that have occured on this port.
1.3.6.1.2.1.8888.1.3.1.1.3ColumnfcConnUnitPortStatTxObjectsread-onlycurrentThe number of frames/packets/IOs/etc that have been transmitted by this port. Note: A Fibre Channel frame starts with SOF and ends with EOF. FC loop devices sh…
1.3.6.1.2.1.8888.1.3.1.1.4ColumnfcConnUnitPortStatRxObjectsread-onlycurrentThe number of frames/packets/IOs/etc that have been received by this port. Note: A Fibre Channel frame starts with SOF and ends with EOF. FC loop devices shoul…
1.3.6.1.2.1.8888.1.3.1.1.5ColumnfcConnUnitPortStatTxElementsread-onlycurrentThe number of octets or bytes that have been transmitted by this port. One second periodic polling of the port. This value is saved and compared with the next …
1.3.6.1.2.1.8888.1.3.1.1.6ColumnfcConnUnitPortStatRxElementsread-onlycurrentThe number of octets or bytes that have been received by this port. One second periodic polling of the port. This value is saved and compared with the next pol…
1.3.6.1.2.1.8888.1.3.1.1.7ColumnfcConnUnitPortStatBBCreditZeroread-onlycurrentCount of transitions in/out of BBcredit zero state. The other side is not providing any credit. Note, this is a Fibre Channel stat only.
1.3.6.1.2.1.8888.1.3.1.1.8ColumnfcConnUnitPortStatInputBuffsFullread-onlycurrentCount of occurrences when all input buffers of a port were full and outbound buffer-to-buffer credit transitioned to zero. There is no credit to provide to oth…
1.3.6.1.2.1.8888.1.3.1.1.9ColumnfcConnUnitPortStatFBSYFramesread-onlycurrentCount of times that FBSY was returned to this port as a result of a frame that could not be delivered to the other end of the link. This occurs if either the F…
1.3.6.1.2.1.8888.1.3.1.1.10ColumnfcConnUnitPortStatPBSYFramesread-onlycurrentCount of times that PBSY was returned to this port as a result of a frame that could not be delivered to the other end of the link. This occurs if the destinat…
1.3.6.1.2.1.8888.1.3.1.1.11ColumnfcConnUnitPortStatFRJTFramesread-onlycurrentCount of times that FRJT was returned to this port as a result of a Frame that was rejected by the fabric. Note, this is the total for all classes and is a Fib…
1.3.6.1.2.1.8888.1.3.1.1.12ColumnfcConnUnitPortStatPRJTFramesread-onlycurrentCount of times that FRJT was returned to this port as a result of a Frame that was rejected at the destination N_Port. Note, this is the total for all classes …
1.3.6.1.2.1.8888.1.3.1.1.13ColumnfcConnUnitPortStatC1RxFramesread-onlycurrentCount of Class 1 Frames received at this port. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.14ColumnfcConnUnitPortStatC1TxFramesread-onlycurrentCount of Class 1 Frames transmitted out this port. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.15ColumnfcConnUnitPortStatC1FBSYFramesread-onlycurrentCount of times that FBSY was returned to this port as a result of a Class 1 Frame that could not be delivered to the other end of the link. This occurs if eith…
1.3.6.1.2.1.8888.1.3.1.1.16ColumnfcConnUnitPortStatC1PBSYFramesread-onlycurrentCount of times that PBSY was returned to this port as a result of a Class 1 Frame that could not be delivered to the other end of the link. This occurs if the …
1.3.6.1.2.1.8888.1.3.1.1.17ColumnfcConnUnitPortStatC1FRJTFramesread-onlycurrentCount of times that FRJT was returned to this port as a result of a Class 1 Frame that was rejected by the fabric. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.18ColumnfcConnUnitPortStatC1PRJTFramesread-onlycurrentCount of times that FRJT was returned to this port as a result of a Class 1 Frame that was rejected at the destination N_Port. Note, this is a Fibre Channel on…
1.3.6.1.2.1.8888.1.3.1.1.19ColumnfcConnUnitPortStatC2RxFramesread-onlycurrentCount of Class 2 Frames received at this port. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.20ColumnfcConnUnitPortStatC2TxFramesread-onlycurrentCount of Class 2 Frames transmitted out this port. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.21ColumnfcConnUnitPortStatC2FBSYFramesread-onlycurrentCount of times that FBSY was returned to this port as a result of a Class 2 Frame that could not be delivered to the other end of the link. This occurs if eith…
1.3.6.1.2.1.8888.1.3.1.1.22ColumnfcConnUnitPortStatC2PBSYFramesread-onlycurrentCount of times that PBSY was returned to this port as a result of a Class 2 Frame that could not be delivered to the other end of the link. This occurs if the …
1.3.6.1.2.1.8888.1.3.1.1.23ColumnfcConnUnitPortStatC2FRJTFramesread-onlycurrentCount of times that FRJT was returned to this port as a result of a Class 2 Frame that was rejected by the fabric. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.24ColumnfcConnUnitPortStatC2PRJTFramesread-onlycurrentCount of times that FRJT was returned to this port as a result of a Class 2 Frame that was rejected at the destination N_Port. Note, this is a Fibre Channel on…
1.3.6.1.2.1.8888.1.3.1.1.25ColumnfcConnUnitPortStatC3RxFramesread-onlycurrentCount of Class 3 Frames received at this port. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.26ColumnfcConnUnitPortStatC3TxFramesread-onlycurrentCount of Class 3 Frames transmitted out of this port. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.27ColumnfcConnUnitPortStatC3Discardsread-onlycurrentCount of Class 3 Frames that were discarded upon reception at this port. There is no FBSY or FRJT generated for Class 3 Frames. They are simply discarded if th…
1.3.6.1.2.1.8888.1.3.1.1.28ColumnfcConnUnitPortStatRxMcastObjectsread-onlycurrentCount of Multicast Frames or Packets received at this port.
1.3.6.1.2.1.8888.1.3.1.1.29ColumnfcConnUnitPortStatTxMcastObjectsread-onlycurrentCount of Multicast Frames or Packets transmitted out this port.
1.3.6.1.2.1.8888.1.3.1.1.30ColumnfcConnUnitPortStatRxBcastObjectsread-onlycurrentCount of Broadcast Frames or Packets received at this port.
1.3.6.1.2.1.8888.1.3.1.1.31ColumnfcConnUnitPortStatTxBcastObjectsread-onlycurrentCount of Broadcast Frames or Packets transmitted out this port. On a Fibre Channel loop, count only OPNr frames generated.
1.3.6.1.2.1.8888.1.3.1.1.32ColumnfcConnUnitPortStatRxLinkResetsread-onlycurrentCount of Link resets. This is the number of LRs received. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.33ColumnfcConnUnitPortStatTxLinkResetsread-onlycurrentCount of Link resets. This is the number LRs transmitted. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.34ColumnfcConnUnitPortStatLinkResetsread-onlycurrentCount of Link resets and LIPs detected at this port. The number times the reset link protocol is initiated. These are the count of the logical resets, a count …
1.3.6.1.2.1.8888.1.3.1.1.35ColumnfcConnUnitPortStatRxOfflineSeqsread-onlycurrentCount of Offline Primitive OLS received at this port. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.36ColumnfcConnUnitPortStatTxOfflineSeqsread-onlycurrentCount of Offline Primitive OLS transmitted by this port. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.37ColumnfcConnUnitPortStatOfflineSeqsread-onlycurrentCount of Offline Primitive sequence received at this port. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.38ColumnfcConnUnitPortStatLinkFailuresread-onlycurrentCount of link failures. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.39ColumnfcConnUnitPortStatInvalidCRCread-onlycurrentCount of frames received with invalid CRC. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Loop ports should not count CRC errors passi…
1.3.6.1.2.1.8888.1.3.1.1.40ColumnfcConnUnitPortStatInvalidTxWordsread-onlycurrentCount of invalid transmission words received at this port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channe…
1.3.6.1.2.1.8888.1.3.1.1.41ColumnfcConnUnitPortStatPSPErrsread-onlycurrentCount of primitive sequence protocol (PSP) errors detected at this port. This count is part of the Link Error Status Block (LESB) FC-PH 29.8). Note, this is a …
1.3.6.1.2.1.8888.1.3.1.1.42ColumnfcConnUnitPortStatLossOfSignalread-onlycurrentCount of instances of signal loss detected at port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel only …
1.3.6.1.2.1.8888.1.3.1.1.43ColumnfcConnUnitPortStatLossOfSyncread-onlycurrentCount of instances of synchronization loss detected at port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Chan…
1.3.6.1.2.1.8888.1.3.1.1.44ColumnfcConnUnitPortStatInvOrderedSetsread-onlycurrentCount of invalid ordered sets received at port. This count is part of the Link Error Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.3.1.1.45ColumnfcConnUnitPortStatFramesTooLongread-onlycurrentCount of frames received at this port where the frame length was greater than what was agreed to in FLOGI/PLOGI. This could be caused by losing the end of fram…
1.3.6.1.2.1.8888.1.3.1.1.46ColumnfcConnUnitPortStatFramesTooShortread-onlycurrentCount of frames received at this port where the frame length was less than the minimum indicated by the frame header - normally 24 bytes, but it could be more …
1.3.6.1.2.1.8888.1.3.1.1.47ColumnfcConnUnitPortStatAddressErrsread-onlycurrentCount of frames received with unknown addressing. e.g. unknown SID or DID. The SID or DID is not known to the routing algorithm. Note, this is a Fibre Channel …
1.3.6.1.2.1.8888.1.3.1.1.48ColumnfcConnUnitPortStatDelimiterErrsread-onlycurrentCount of invalid frame delimiters received at this port. An example is a frame with a class 2 start and and a class 3 at the end. Note, this is a Fibre Channel…
1.3.6.1.2.1.8888.1.3.1.1.49ColumnfcConnUnitPortStatEncodingErrsread-onlycurrentCount of disparity errors received at this port. Note, this is a Fibre Channel only stat.
1.3.6.1.2.1.8888.1.4NodefcMgmtSNS
1.3.6.1.2.1.8888.1.4.1TablefcConnUnitSnsTablenot-accessiblecurrentThis table contains an entry for each object registered with this port in the switch.
1.3.6.1.2.1.8888.1.4.1.1RowfcConnUnitSnsEntrynot-accessiblecurrentThe Simple Name Server table for the port represented by fcConnUnitSnsPortName .
1.3.6.1.2.1.8888.1.4.1.1.1ColumnfcConnUnitSnsPortIdentifierread-onlycurrentThe Port Identifier for this entry in the SNS table.
1.3.6.1.2.1.8888.1.4.1.1.2ColumnfcConnUnitSnsPortNameread-onlycurrentThe Port WWN for this entry in the SNS table.
1.3.6.1.2.1.8888.1.4.1.1.3ColumnfcConnUnitSnsNodeNameread-onlycurrentThe Node Name for this entry in the SNS table.
1.3.6.1.2.1.8888.1.4.1.1.4ColumnfcConnUnitSnsClassOfSvcread-onlycurrentThe Classes of Service offered by this entry in the SNS table.
1.3.6.1.2.1.8888.1.4.1.1.5ColumnfcConnUnitSnsNodeIPAddressread-onlycurrentThe IPv6 formatted address of the Node for this entry in the SNS table.
1.3.6.1.2.1.8888.1.4.1.1.6ColumnfcConnUnitSnsProcAssocread-onlycurrentThe Process Associator for this entry in the SNS table.
1.3.6.1.2.1.8888.1.4.1.1.7ColumnfcConnUnitSnsFC4Typeread-onlycurrentThe FC-4 Types supported by this entry in the SNS table.
1.3.6.1.2.1.8888.1.4.1.1.8ColumnfcConnUnitSnsPortTyperead-onlycurrentThe Port Type of this entry in the SNS table.
1.3.6.1.2.1.8888.1.4.1.1.9ColumnfcConnUnitSnsPortIPAddressread-onlycurrentThe IPv6 formatted address of this entry in the SNS table.
1.3.6.1.2.1.8888.1.4.1.1.10ColumnfcConnUnitSnsFabricPortNameread-onlycurrentThe Fabric Port name of this entry in the SNS table.
1.3.6.1.2.1.8888.1.4.1.1.11ColumnfcConnUnitSnsHardAddressread-onlycurrentThe Hard ALPA of this entry in the SNS table.
1.3.6.1.2.1.8888.1.4.1.1.12ColumnfcConnUnitSnsSymbolicPortNameread-onlycurrentThe Symbolic Port Name of this entry in the SNS table.
1.3.6.1.2.1.8888.1.4.1.1.13ColumnfcConnUnitSnsSymbolicNodeNameread-onlycurrentThe Symbolic Node Name of this entry in the SNS table.
1.3.6.1.2.1.8888.2NodefcMgmtConformance
1.3.6.1.2.1.8888.2.1NodefcMgmtCompliances
1.3.6.1.2.1.8888.2.1.1CompliancefcMgmtCompliancecurrentThe compliance statement for Fibre Channel entities which implement this MIB module.
1.3.6.1.2.1.8888.2.2NodefcMgmtGroups
1.3.6.1.2.1.8888.2.2.1GroupfcConnUnitGroupcurrentThe collection of objects providing Fibre Channel connectivity unit instrumentation and control.
1.3.6.1.2.1.8888.2.2.2GroupfcCuEventGroupcurrentThe collection of objects providing Fibre Channel connectivity unit event information.
1.3.6.1.2.1.8888.2.2.3GroupfcCuLinkGroupcurrentThe collection of objects providing Fibre Channel connectivity unit link (topology) information.
1.3.6.1.2.1.8888.2.2.4GroupfcCuPortStatsGroupcurrentThe collection of objects providing Fibre Channel connectivity unit port statistics.
1.3.6.1.2.1.8888.2.2.5GroupfcCuSNSGroupcurrentThe collection of objects providing Fibre Channel connectivity unit simple name server information.
1.3.6.1.2.1.8888.2.2.6GroupfcCuTrapFiltersGroupcurrentThe collection of objects controlling SNMP notification (i.e., trap) destinations.
1.3.6.1.2.1.8888.2.2.7GroupfcCuNotificationsGroupcurrentThe set of SNMP notifications which an agent is required to implement.
Type Definitions
NameSyntaxStatusDescription
FcEventSeverityINTEGER { unknown (1), emergency (2), alert (3), critical (4), error (5), warning (6), notify (7), info (8), debug (9), mark (10) }currentThe set of values which define the event severity that will be logged by this connectivity unit. Values unknown (1) through debug (9) are essentially self-explanatory; mark (10) means that all messages are logged.
FcGlobalIdOCTET STRING (SIZE(16))currentRepresents the Worldwide Name (WWN; IEEE 124-bit variety) associated with a Fibre Channel (FC) entity.
FcNameIdOCTET STRING (SIZE (8))currentRepresents the Worldwide Name (WWN; IEEE 60-bit variety; standard part of T11 definitions for fibre channel) associated with a Fibre Channel (FC) entity.
FcPortFCClassBITS { unknown (0), classF (1), class1 (2), class2 (3), class3 (4), class4 (5), class5 (6), class6 (7) }currentRepresents the class(es) of service represented on a given port, in a given operational context.
FcUnitTypeINTEGER { unknown(1), other(2), hub(3), switch(4), gateway(5), converter(6), hba(7), proxyAgent(8), storageDevice(9), host(10), storageSubsystem(11), module(12), swDriver(13), storageAccessDevice(14) }currentunknown (1) cannot be determined other (2) none of the following hub (3) passive connectivity unit supporting loop protocol. switch (4) active connectivity unit supporting multiple protocols. gateway (5) unit that conve…