MIB Viewer

FLARION-TRAP-MIB

56 objects
No module-level DESCRIPTION found.
Imported Objects
FLARION-MIBAddtlInfo AlarmSeverity flarion MoType rrCommonMib
SNMPv2-SMIMODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
OIDNameAccessStatusDescription
1.3.6.1.4.1.8603.1.1.1NoderrTrapVars
1.3.6.1.4.1.8603.1.1.1.1ScalarrrTimeStampread-onlydeprecatedThe time at which the event was generated. This value is expressed in seconds since 00:00:00 UTC, January 1, 1970 (see time(2)).
1.3.6.1.4.1.8603.1.1.1.2ScalarrrSeqNumread-onlydeprecatedThe event sequence number.
1.3.6.1.4.1.8603.1.1.1.3ScalarrrSeverityread-onlydeprecatedThe event severity.
1.3.6.1.4.1.8603.1.1.1.4ScalarrrMoTyperead-onlydeprecatedType managed object associated with this trap.
1.3.6.1.4.1.8603.1.1.1.5ScalarrrMoIdread-onlydeprecatedThe instance of the managed object logical identifier.
1.3.6.1.4.1.8603.1.1.1.6ScalarrrAddtlInforead-onlydeprecatedEvent description.
1.3.6.1.4.1.8603.1.1.2NoderrTraps
1.3.6.1.4.1.8603.1.1.2.0NoderrTrapSpecific
1.3.6.1.4.1.8603.1.1.2.0.1NotificationalarmTrapdeprecatedAlarm notification.
1.3.6.1.4.1.8603.1.1.2.0.2NotificationbootStatusUpdeprecatedThe system is up and running.
1.3.6.1.4.1.8603.1.1.2.0.3NotificationbootStatusDowndeprecatedThe system has failed to boot or the system is shutting down.
1.3.6.1.4.1.8603.1.1.2.0.120NotificationmcuOperStatusdeprecatedMCU operational status changed.
1.3.6.1.4.1.8603.1.1.2.0.121NotificationmcuFaultLedStatusdeprecatedMCU fault LED status changed.
1.3.6.1.4.1.8603.1.1.2.0.122NotificationmcuTempStatusdeprecatedMCU temperature status changed.
1.3.6.1.4.1.8603.1.1.2.0.123NotificationmcuVoltageStatusdeprecatedMCU voltage status changed.
1.3.6.1.4.1.8603.1.1.2.0.160NotificationmlpppStatusdeprecatedMultilink PPP status changed.
1.3.6.1.4.1.8603.1.1.2.0.200NotificationbbuOperStatusdeprecatedBBU operational status changed.
1.3.6.1.4.1.8603.1.1.2.0.201NotificationbbuFaultLedStatusdeprecatedBBU fault LED status changed.
1.3.6.1.4.1.8603.1.1.2.0.202NotificationbbuTempStatusdeprecatedBBU temperature status changed.
1.3.6.1.4.1.8603.1.1.2.0.203NotificationbbuVoltageStatusdeprecatedBBU voltage status changed.
1.3.6.1.4.1.8603.1.1.2.0.204NotificationbbuDspStatusdeprecatedBBU DSP status changed.
1.3.6.1.4.1.8603.1.1.2.0.280NotificationalarmInputStatusdeprecatedAlarm input status changed.
1.3.6.1.4.1.8603.1.1.2.0.350NotificationaccountingRadiusStatusdeprecatedAccounting/RADIUS server status changed.
1.3.6.1.4.1.8603.10NodeflarionTraps
1.3.6.1.4.1.8603.10.1NodeflaTrapVars
1.3.6.1.4.1.8603.10.1.1ScalarflaTimeStampread-onlycurrentThe time at which the event was generated. This value is expressed in seconds since 00:00:00 UTC, January 1, 1970 (see time(2)).
1.3.6.1.4.1.8603.10.1.2ScalarflaSeqNumread-onlycurrentThe event sequence number.
1.3.6.1.4.1.8603.10.1.3ScalarflaSeverityread-onlydeprecatedThe event severity.
1.3.6.1.4.1.8603.10.1.4ScalarflaMoTyperead-onlycurrentType managed object associated with this trap.
1.3.6.1.4.1.8603.10.1.5ScalarflaMoIdread-onlycurrentThe instance of the managed object logical identifier.
1.3.6.1.4.1.8603.10.1.6ScalarflaAddtlInforead-onlycurrentEvent description.
1.3.6.1.4.1.8603.10.2NodeflaTraps
1.3.6.1.4.1.8603.10.2.0NodeflaTrapPrefix
1.3.6.1.4.1.8603.10.2.0.1NotificationmcuBootStatusUpcurrentThe MCU software is up and running.
1.3.6.1.4.1.8603.10.2.0.2NotificationmcuBootStatusDowncurrentThe MCU software is shutting down.
1.3.6.1.4.1.8603.10.2.0.3NotificationmcuOperStatusUpdeprecatedMCU operational status is up.
1.3.6.1.4.1.8603.10.2.0.4NotificationmcuOperStatusDowndeprecatedMCU operational status is down.
1.3.6.1.4.1.8603.10.2.0.5NotificationmlpppStatusUpcurrentMultilink PPP status is up.
1.3.6.1.4.1.8603.10.2.0.6NotificationmlpppStatusDowncurrentMultilink PPP status is up.
1.3.6.1.4.1.8603.10.2.0.7NotificationbbuOperStatusUpcurrentBBU card operational status is up.
1.3.6.1.4.1.8603.10.2.0.8NotificationbbuOperStatusDowncurrentBBU card operational status is down.
1.3.6.1.4.1.8603.10.2.0.9NotificationbbuOperStatusNotPresentcurrentBBU card operational status is not present.
1.3.6.1.4.1.8603.10.2.0.10NotificationbbuTempNormalcurrentBBU temperature has transitioned inot normal operating range.
1.3.6.1.4.1.8603.10.2.0.11NotificationbbuTempHighcurrentBBU temperature has transitioned into a high operating range.
1.3.6.1.4.1.8603.10.2.0.12NotificationbbuTempSeverecurrentBBU temperature has transitioned into a severe operating range.
1.3.6.1.4.1.8603.10.2.0.13NotificationbbuTempCriticalcurrentBBU temperature has transitioned into a critical operating range.
1.3.6.1.4.1.8603.10.2.0.14NotificationbbuVoltageNormalcurrentBBU voltage has transitioned into normal operating range.
1.3.6.1.4.1.8603.10.2.0.15NotificationbbuVoltageHighcurrentBBU voltage has transitioned above normal operating limits.
1.3.6.1.4.1.8603.10.2.0.16NotificationbbuVoltageLowcurrentBBU voltage has transitioned below normal operating limits.
1.3.6.1.4.1.8603.10.2.0.17NotificationdspStatusActivecurrentDSP has transitioned into the Active state. In this state, mobiles are allowed to establish connections and data traffic can be received/transmitted.
1.3.6.1.4.1.8603.10.2.0.18NotificationdspStatusStandbycurrentDSP has transitioned into the Disabled/Standby state. In this state, mobiles can not establish connections and data traffic can not be received/transmitted. Th…
1.3.6.1.4.1.8603.10.2.0.19NotificationdspStatusOoscurrentDSP has transitioned into the Out of Service state.
1.3.6.1.4.1.8603.10.2.0.20NotificationdspStatusNonOperationalcurrentDSP has transitioned into the Non Operational state. This state is entered when the system is unable to determine the condition of the DSP.
1.3.6.1.4.1.8603.10.2.0.21NotificationaccountingRadiusUpcurrentAccounting/RADIUS server is up.
1.3.6.1.4.1.8603.10.2.0.22NotificationaccountingRadiusDowncurrentAccounting/RADIUS server is down.