MIB Viewer

FRAME-RELAY-DTE-SVC-MIB

50 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.2.1.10.32.7NodeframeRelayDteSvc
1.3.6.1.2.1.10.32.7.1NodefrDteSvc
1.3.6.1.2.1.10.32.7.1.1TablefrSvcDlcmiTablenot-accessiblemandatoryThe Parameters for the Switched Virtual Circuit Link Connection Management Interface for the frame relay service on this interface.
1.3.6.1.2.1.10.32.7.1.1.1RowfrSvcDlcmiEntrynot-accessiblemandatoryThe information regarding a single switched Data Link Connection Management Interface.
1.3.6.1.2.1.10.32.7.1.1.1.1ColumnfrSvcDlcmiIfIndexread-onlymandatoryThe ifIndex value of the corresponding ifEntry.
1.3.6.1.2.1.10.32.7.1.1.1.2ColumnfrSvcDlcmiStateread-writemandatoryThis variable states which Data Link Connection Management scheme is on the Frame Relay switched interface.
1.3.6.1.2.1.10.32.7.1.1.1.3ColumnfrSvcDlcmiMaxNumCallsread-onlymandatoryIndicates the maximum number of calls allowed on the interface.
1.3.6.1.2.1.10.32.7.1.1.1.4ColumnfrSvcDlcmiCallSetupTimerread-writemandatoryThis timer is started when the CALL SETUP message is sent. The timer is stopped when the sender receives a CALL PROCEEDING message. If the timer, expressed in …
1.3.6.1.2.1.10.32.7.1.1.1.5ColumnfrSvcDlcmiCallProceedingTimerread-writemandatoryThis timer is started when the CALL PROCEEDING message is sent. The timer is stopped when the sender receives a CALL CONNECT message. If the timer, expressed i…
1.3.6.1.2.1.10.32.7.1.1.1.6ColumnfrSvcDlcmiCallDisconnectTimerread-writemandatoryThis timer is started when the DISCONNECT message is sent. The timer is stopped when the sender receives a RELEASE message. The sender then responds with a REL…
1.3.6.1.2.1.10.32.7.1.1.1.7ColumnfrSvcDlcmiCallReleaseTimerread-writemandatoryThis timer is started if timer T305 expires. This timer is stopped when the sender receives a RELEASE message. If the timer, expressed in seconds, expires, the…
1.3.6.1.2.1.10.32.7.1.1.1.8ColumnfrSvcDlcmiStatusEnquiryTimerread-writemandatoryThis timer is started when a STATUS ENQUIRY message is sent. If a STATUS message is received, the timer will be stopped. If the Timer expires it may be retried…
1.3.6.1.2.1.10.32.7.1.1.1.9ColumnfrSvcDlcmiErrorThresholdread-writemandatoryThis is the implementation specific number of times that the STATUS ENQUIRY Timer, T322, will be retried.
1.3.6.1.2.1.10.32.7.1.1.1.10ColumnfrSvcDlcmiResetSentTimerread-writemandatoryThis timer is started when a RESTART message is sent. If a RESTART ACKNOWLEDGEmessage is received, the timer will be stopped. If the Timer expires expires it m…
1.3.6.1.2.1.10.32.7.1.1.1.11ColumnfrSvcDlcmiResetAckTimerread-writemandatoryThis timer is started when a RESTART message is received. At this time the receiving entity shall initiate the appropriate internal actions to return the speci…
1.3.6.1.2.1.10.32.7.1.1.1.12ColumnfrSvcDlcmiIdleTimerread-writemandatoryThis is the maximum time allowed without any frames being exchanged. The default for this timer is 30 seconds.
1.3.6.1.2.1.10.32.7.1.1.1.13ColumnfrSvcDlcmiRetransmissionTimerread-writemandatoryThis is the re-transmission timer. It is started upon transmission of frames. When a response is received, the timer will be shut down. If the timer expires , …
1.3.6.1.2.1.10.32.7.1.1.1.14ColumnfrSvcDlcmiNumRetransmissionsread-writemandatoryThis value indicates the number of times T200 timer will be retried. When N200 times have been reached, a DL-RELEASE message will be sent to the Layer 3 entity…
1.3.6.1.2.1.10.32.7.1.1.1.15ColumnfrSvcDlcmiMaxInfoFieldSizeread-writemandatoryThis value indicates the maximum number of octets in an Information field. The default value is 260 octets.
1.3.6.1.2.1.10.32.7.1.1.1.16ColumnfrSvcDlcmiMaxInfoFramesread-writemandatoryThis value indicates the maximum number of sequentially numbered I frames that may be outstanding (that is, unacknowledged) at any given time. This number shal…
1.3.6.1.2.1.10.32.7.1.1.1.17ColumnfrSvcDlcmiQ922Stateread-onlymandatoryThis value indicates the state of the Q.922 Point to Point Data Link Layer Negotiation.
1.3.6.1.2.1.10.32.7.1.2TablefrSvcTablenot-accessiblemandatoryA table containing information about specific Data Link Connection Identifiers and corresponding switched virtual circuits.
1.3.6.1.2.1.10.32.7.1.2.1RowfrSvcEntrynot-accessiblemandatoryThe information regarding a single switched Data Link Connection Identifier.
1.3.6.1.2.1.10.32.7.1.2.1.1ColumnfrSvcIfIndexread-onlymandatoryThe ifIndex Value of the ifEntry this virtual circuit is layered onto.
1.3.6.1.2.1.10.32.7.1.2.1.2ColumnfrSvcDlciread-onlymandatoryThe Data Link Connection Identifier for this virtual circuit.
1.3.6.1.2.1.10.32.7.1.2.1.3ColumnfrSvcReceivedFECNsread-onlymandatoryNumber of frames received from the network in- dicating forward congestion since the virtual circuit was created.
1.3.6.1.2.1.10.32.7.1.2.1.4ColumnfrSvcReceivedBECNsread-onlymandatoryNumber of frames received from the network in- dicating backward congestion since the virtual circuit was created.
1.3.6.1.2.1.10.32.7.1.2.1.5ColumnfrSvcSentFramesread-onlymandatoryThe number of frames sent from this virtual circuit since it was created.
1.3.6.1.2.1.10.32.7.1.2.1.6ColumnfrSvcSentOctetsread-onlymandatoryThe number of octets sent from this virtual circuit since it was created.
1.3.6.1.2.1.10.32.7.1.2.1.7ColumnfrSvcReceivedFramesread-onlymandatoryNumber of frames received over this virtual circuit since it was created.
1.3.6.1.2.1.10.32.7.1.2.1.8ColumnfrSvcReceivedOctetsread-onlymandatoryNumber of octets received over this virtual circuit since it was created.
1.3.6.1.2.1.10.32.7.1.2.1.9ColumnfrSvcCreationTimeread-onlymandatoryThe value of sysUpTime when the virtual cir- cuit was created.
1.3.6.1.2.1.10.32.7.1.2.1.10ColumnfrSvcInMaxFmifSizeread-writemandatoryThis variable indicates the maximum amount of end user data octets in a frame for in the direction of the calling user to the called user. The default value is…
1.3.6.1.2.1.10.32.7.1.2.1.11ColumnfrSvcOutMaxFmifSizeread-writemandatoryThis variable indicates the maximum amount of end user data octets in a frame for in the direction of the called user to the calling user. The default value is…
1.3.6.1.2.1.10.32.7.1.2.1.12ColumnfrSvcInCommittedBurstread-writemandatoryThis variable indicates the maximum amount of data, in bits, that the network agrees to accept under normal conditions, during the measurement interval. The de…
1.3.6.1.2.1.10.32.7.1.2.1.13ColumnfrSvcOutCommittedBurstread-writemandatoryThis variable indicates the maximum amount of data, in bits, that the network agrees to transfer under normal conditions, during the measurement interval. The …
1.3.6.1.2.1.10.32.7.1.2.1.14ColumnfrSvcInExcessBurstread-writemandatoryThis variable indicates the maximum amount of uncommitted data bits that the network will at- tempt to receive over the measurement interval. By default, if no…
1.3.6.1.2.1.10.32.7.1.2.1.15ColumnfrSvcOutExcessBurstread-writemandatoryThis variable indicates the maximum amount of uncommitted data bits that the network will at- tempt to deliver over the measurement interval. By default, if no…
1.3.6.1.2.1.10.32.7.1.2.1.16ColumnfrSvcInCIRread-writemandatoryCIR is the average number of 'Frame Re- lay Information Field' bits received per second across a user network interface to the calling user, measured over the …
1.3.6.1.2.1.10.32.7.1.2.1.17ColumnfrSvcOutCIRread-writemandatoryCIR is the average number of 'Frame Re- lay Information Field' bits transferred per second across a user network interface from the calling user, measured over…
1.3.6.1.2.1.10.32.7.1.2.1.18ColumnfrSvcInMinCIRread-writemandatoryMinimum Acceptable CIR is the lowest throughput value, in the direction to the calling user, expressed in bits per second, that the calling user is willing to …
1.3.6.1.2.1.10.32.7.1.2.1.19ColumnfrSvcOutMinCIRread-writemandatoryMinimum Acceptable CIR is the lowest throughput value, in the direction from the calling user, expressed in bits per second, that the calling user is willing t…
1.3.6.1.2.1.10.32.7.1.2.1.20ColumnfrSvcStateread-onlymandatoryIndicates whether the Connection has been completed and data can proceed (2), or if the call setup is still in process (1).
1.3.6.1.2.1.10.32.7.1.2.1.21ColumnfrSvcCallReferenceValueread-onlymandatoryIndicates the call identity number of the call on the interface.
1.3.6.1.2.1.10.32.7.1.2.1.22ColumnfrSvcCallingAddrread-writemandatoryIndicates the address of the calling party.
1.3.6.1.2.1.10.32.7.1.2.1.23ColumnfrSvcCallingSubAddrread-writemandatoryIndicates the sub-address of the calling party.
1.3.6.1.2.1.10.32.7.1.2.1.24ColumnfrSvcCalledAddrread-writemandatoryIndicates the address of the called party.
1.3.6.1.2.1.10.32.7.1.2.1.25ColumnfrSvcCalledSubAddrread-writemandatoryIndicates the sub-address of the called party.
1.3.6.1.2.1.10.32.7.1.2.1.26ColumnfrSvcCallSetupread-writemandatoryIndicates whether the call should be Setup or Disconnected.
1.3.6.1.2.1.10.32.7.1.2.1.27ColumnfrSvcCallOriginationread-onlymandatoryIndicates the direction of the call. identifies the circuit as the calling (local) or the called side (remote).