FRAME-RELAY-DTE-SVC-MIB
50 objects
No module-level DESCRIPTION found.
Imported Objects
| IF-MIB | InterfaceIndex |
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1315-MIB | DLCI frame-relay |
| SNMPv2-SMI | Counter32 Integer32 TimeTicks |
| SNMPv2-TC-v1 | DisplayString RowStatus TimeStamp |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.2.1.10.32.7 | NodeframeRelayDteSvc | |||
| 1.3.6.1.2.1.10.32.7.1 | NodefrDteSvc | |||
| 1.3.6.1.2.1.10.32.7.1.1 | TablefrSvcDlcmiTable | not-accessible | mandatory | The Parameters for the Switched Virtual Circuit Link Connection Management Interface for the frame relay service on this interface. |
| 1.3.6.1.2.1.10.32.7.1.1.1 | RowfrSvcDlcmiEntry | not-accessible | mandatory | The information regarding a single switched Data Link Connection Management Interface. |
| 1.3.6.1.2.1.10.32.7.1.1.1.1 | ColumnfrSvcDlcmiIfIndex | read-only | mandatory | The ifIndex value of the corresponding ifEntry. |
| 1.3.6.1.2.1.10.32.7.1.1.1.2 | ColumnfrSvcDlcmiState | read-write | mandatory | This variable states which Data Link Connection Management scheme is on the Frame Relay switched interface. |
| 1.3.6.1.2.1.10.32.7.1.1.1.3 | ColumnfrSvcDlcmiMaxNumCalls | read-only | mandatory | Indicates the maximum number of calls allowed on the interface. |
| 1.3.6.1.2.1.10.32.7.1.1.1.4 | ColumnfrSvcDlcmiCallSetupTimer | read-write | mandatory | This timer is started when the CALL SETUP message is sent. The timer is stopped when the sender receives a CALL PROCEEDING message. If the timer, expressed in … |
| 1.3.6.1.2.1.10.32.7.1.1.1.5 | ColumnfrSvcDlcmiCallProceedingTimer | read-write | mandatory | This timer is started when the CALL PROCEEDING message is sent. The timer is stopped when the sender receives a CALL CONNECT message. If the timer, expressed i… |
| 1.3.6.1.2.1.10.32.7.1.1.1.6 | ColumnfrSvcDlcmiCallDisconnectTimer | read-write | mandatory | This timer is started when the DISCONNECT message is sent. The timer is stopped when the sender receives a RELEASE message. The sender then responds with a REL… |
| 1.3.6.1.2.1.10.32.7.1.1.1.7 | ColumnfrSvcDlcmiCallReleaseTimer | read-write | mandatory | This timer is started if timer T305 expires. This timer is stopped when the sender receives a RELEASE message. If the timer, expressed in seconds, expires, the… |
| 1.3.6.1.2.1.10.32.7.1.1.1.8 | ColumnfrSvcDlcmiStatusEnquiryTimer | read-write | mandatory | This timer is started when a STATUS ENQUIRY message is sent. If a STATUS message is received, the timer will be stopped. If the Timer expires it may be retried… |
| 1.3.6.1.2.1.10.32.7.1.1.1.9 | ColumnfrSvcDlcmiErrorThreshold | read-write | mandatory | This is the implementation specific number of times that the STATUS ENQUIRY Timer, T322, will be retried. |
| 1.3.6.1.2.1.10.32.7.1.1.1.10 | ColumnfrSvcDlcmiResetSentTimer | read-write | mandatory | This timer is started when a RESTART message is sent. If a RESTART ACKNOWLEDGEmessage is received, the timer will be stopped. If the Timer expires expires it m… |
| 1.3.6.1.2.1.10.32.7.1.1.1.11 | ColumnfrSvcDlcmiResetAckTimer | read-write | mandatory | This timer is started when a RESTART message is received. At this time the receiving entity shall initiate the appropriate internal actions to return the speci… |
| 1.3.6.1.2.1.10.32.7.1.1.1.12 | ColumnfrSvcDlcmiIdleTimer | read-write | mandatory | This is the maximum time allowed without any frames being exchanged. The default for this timer is 30 seconds. |
| 1.3.6.1.2.1.10.32.7.1.1.1.13 | ColumnfrSvcDlcmiRetransmissionTimer | read-write | mandatory | This is the re-transmission timer. It is started upon transmission of frames. When a response is received, the timer will be shut down. If the timer expires , … |
| 1.3.6.1.2.1.10.32.7.1.1.1.14 | ColumnfrSvcDlcmiNumRetransmissions | read-write | mandatory | This value indicates the number of times T200 timer will be retried. When N200 times have been reached, a DL-RELEASE message will be sent to the Layer 3 entity… |
| 1.3.6.1.2.1.10.32.7.1.1.1.15 | ColumnfrSvcDlcmiMaxInfoFieldSize | read-write | mandatory | This value indicates the maximum number of octets in an Information field. The default value is 260 octets. |
| 1.3.6.1.2.1.10.32.7.1.1.1.16 | ColumnfrSvcDlcmiMaxInfoFrames | read-write | mandatory | This value indicates the maximum number of sequentially numbered I frames that may be outstanding (that is, unacknowledged) at any given time. This number shal… |
| 1.3.6.1.2.1.10.32.7.1.1.1.17 | ColumnfrSvcDlcmiQ922State | read-only | mandatory | This value indicates the state of the Q.922 Point to Point Data Link Layer Negotiation. |
| 1.3.6.1.2.1.10.32.7.1.2 | TablefrSvcTable | not-accessible | mandatory | A table containing information about specific Data Link Connection Identifiers and corresponding switched virtual circuits. |
| 1.3.6.1.2.1.10.32.7.1.2.1 | RowfrSvcEntry | not-accessible | mandatory | The information regarding a single switched Data Link Connection Identifier. |
| 1.3.6.1.2.1.10.32.7.1.2.1.1 | ColumnfrSvcIfIndex | read-only | mandatory | The ifIndex Value of the ifEntry this virtual circuit is layered onto. |
| 1.3.6.1.2.1.10.32.7.1.2.1.2 | ColumnfrSvcDlci | read-only | mandatory | The Data Link Connection Identifier for this virtual circuit. |
| 1.3.6.1.2.1.10.32.7.1.2.1.3 | ColumnfrSvcReceivedFECNs | read-only | mandatory | Number of frames received from the network in- dicating forward congestion since the virtual circuit was created. |
| 1.3.6.1.2.1.10.32.7.1.2.1.4 | ColumnfrSvcReceivedBECNs | read-only | mandatory | Number of frames received from the network in- dicating backward congestion since the virtual circuit was created. |
| 1.3.6.1.2.1.10.32.7.1.2.1.5 | ColumnfrSvcSentFrames | read-only | mandatory | The number of frames sent from this virtual circuit since it was created. |
| 1.3.6.1.2.1.10.32.7.1.2.1.6 | ColumnfrSvcSentOctets | read-only | mandatory | The number of octets sent from this virtual circuit since it was created. |
| 1.3.6.1.2.1.10.32.7.1.2.1.7 | ColumnfrSvcReceivedFrames | read-only | mandatory | Number of frames received over this virtual circuit since it was created. |
| 1.3.6.1.2.1.10.32.7.1.2.1.8 | ColumnfrSvcReceivedOctets | read-only | mandatory | Number of octets received over this virtual circuit since it was created. |
| 1.3.6.1.2.1.10.32.7.1.2.1.9 | ColumnfrSvcCreationTime | read-only | mandatory | The value of sysUpTime when the virtual cir- cuit was created. |
| 1.3.6.1.2.1.10.32.7.1.2.1.10 | ColumnfrSvcInMaxFmifSize | read-write | mandatory | This variable indicates the maximum amount of end user data octets in a frame for in the direction of the calling user to the called user. The default value is… |
| 1.3.6.1.2.1.10.32.7.1.2.1.11 | ColumnfrSvcOutMaxFmifSize | read-write | mandatory | This variable indicates the maximum amount of end user data octets in a frame for in the direction of the called user to the calling user. The default value is… |
| 1.3.6.1.2.1.10.32.7.1.2.1.12 | ColumnfrSvcInCommittedBurst | read-write | mandatory | This variable indicates the maximum amount of data, in bits, that the network agrees to accept under normal conditions, during the measurement interval. The de… |
| 1.3.6.1.2.1.10.32.7.1.2.1.13 | ColumnfrSvcOutCommittedBurst | read-write | mandatory | This variable indicates the maximum amount of data, in bits, that the network agrees to transfer under normal conditions, during the measurement interval. The … |
| 1.3.6.1.2.1.10.32.7.1.2.1.14 | ColumnfrSvcInExcessBurst | read-write | mandatory | This variable indicates the maximum amount of uncommitted data bits that the network will at- tempt to receive over the measurement interval. By default, if no… |
| 1.3.6.1.2.1.10.32.7.1.2.1.15 | ColumnfrSvcOutExcessBurst | read-write | mandatory | This variable indicates the maximum amount of uncommitted data bits that the network will at- tempt to deliver over the measurement interval. By default, if no… |
| 1.3.6.1.2.1.10.32.7.1.2.1.16 | ColumnfrSvcInCIR | read-write | mandatory | CIR is the average number of 'Frame Re- lay Information Field' bits received per second across a user network interface to the calling user, measured over the … |
| 1.3.6.1.2.1.10.32.7.1.2.1.17 | ColumnfrSvcOutCIR | read-write | mandatory | CIR is the average number of 'Frame Re- lay Information Field' bits transferred per second across a user network interface from the calling user, measured over… |
| 1.3.6.1.2.1.10.32.7.1.2.1.18 | ColumnfrSvcInMinCIR | read-write | mandatory | Minimum Acceptable CIR is the lowest throughput value, in the direction to the calling user, expressed in bits per second, that the calling user is willing to … |
| 1.3.6.1.2.1.10.32.7.1.2.1.19 | ColumnfrSvcOutMinCIR | read-write | mandatory | Minimum Acceptable CIR is the lowest throughput value, in the direction from the calling user, expressed in bits per second, that the calling user is willing t… |
| 1.3.6.1.2.1.10.32.7.1.2.1.20 | ColumnfrSvcState | read-only | mandatory | Indicates whether the Connection has been completed and data can proceed (2), or if the call setup is still in process (1). |
| 1.3.6.1.2.1.10.32.7.1.2.1.21 | ColumnfrSvcCallReferenceValue | read-only | mandatory | Indicates the call identity number of the call on the interface. |
| 1.3.6.1.2.1.10.32.7.1.2.1.22 | ColumnfrSvcCallingAddr | read-write | mandatory | Indicates the address of the calling party. |
| 1.3.6.1.2.1.10.32.7.1.2.1.23 | ColumnfrSvcCallingSubAddr | read-write | mandatory | Indicates the sub-address of the calling party. |
| 1.3.6.1.2.1.10.32.7.1.2.1.24 | ColumnfrSvcCalledAddr | read-write | mandatory | Indicates the address of the called party. |
| 1.3.6.1.2.1.10.32.7.1.2.1.25 | ColumnfrSvcCalledSubAddr | read-write | mandatory | Indicates the sub-address of the called party. |
| 1.3.6.1.2.1.10.32.7.1.2.1.26 | ColumnfrSvcCallSetup | read-write | mandatory | Indicates whether the call should be Setup or Disconnected. |
| 1.3.6.1.2.1.10.32.7.1.2.1.27 | ColumnfrSvcCallOrigination | read-only | mandatory | Indicates the direction of the call. identifies the circuit as the calling (local) or the called side (remote). |