MIB Viewer

FRDTE-OPT-MIB

137 objects
No module-level DESCRIPTION found.
Imported Objects
OIDNameAccessStatusDescription
1.3.6.1.4.1.449Nodecodex
1.3.6.1.4.1.449.2NodecdxProductSpecific
1.3.6.1.4.1.449.2.1Nodecdx6500
1.3.6.1.4.1.449.2.1.2Nodecdx6500Configuration
1.3.6.1.4.1.449.2.1.2.1Nodecdx6500CfgProtocolGroup
1.3.6.1.4.1.449.2.1.2.1.1Nodecdx6500PCTPortProtocolGroup
1.3.6.1.4.1.449.2.1.2.1.1.5Tablecdx6500PCTFRDTEPortTablenot-accessiblemandatoryAll of the configuration parameters relevant to the Frame Relay DTE Port table.
1.3.6.1.4.1.449.2.1.2.1.1.5.1Rowcdx6500PCTFRDTEPortEntrynot-accessiblemandatoryA row of FRI Port configuration parameters.
1.3.6.1.4.1.449.2.1.2.1.1.5.1.1Columncdx6500frdtepCfgPortNumread-onlymandatorySpecifies the Port number for the Frame Relay Interface port you are selecting.
1.3.6.1.4.1.449.2.1.2.1.1.5.1.2Columncdx6500frdtepConnectionTyperead-writemandatorySpecify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required dtr - dedicated…
1.3.6.1.4.1.449.2.1.2.1.1.5.1.3Columncdx6500frdtepClockSourceread-writemandatoryint - internal clock source ext - external clock source extint - Internal receive and external transmit clock source (DCE only). extlp - external receive and l…
1.3.6.1.4.1.449.2.1.2.1.1.5.1.4Columncdx6500frdtepClockSpeedread-writemandatoryThis is the speed of the port in bits per second, when using internal clocking. The highest available speed is dependent on the card type,and on the interface …
1.3.6.1.4.1.449.2.1.2.1.1.5.1.5Columncdx6500frdtepMaxStationsread-onlydeprecatedThis is the highest station number to be configured on this FRI port. It is used to limit the configuration of stations.
1.3.6.1.4.1.449.2.1.2.1.1.5.1.6Columncdx6500frdtepFrameSeqCountingread-onlymandatoryPort uses normal or extended frame sequence numbering: normal - normal sequencing (modulo 8) ext - extended sequencing (modulo 128) nc - Skipped during configu…
1.3.6.1.4.1.449.2.1.2.1.1.5.1.7Columncdx6500frdtepPktSeqCountingread-writemandatoryPort uses normal or extended packet level sequence numbers normal - normal sequencing (Modulo 8) ext - extended sequencing (Modulo 128) nc - Skipped during con…
1.3.6.1.4.1.449.2.1.2.1.1.5.1.8Columncdx6500frdtepCtrlProtocolread-writemandatoryWhether ANSI T1.617 Annex D or LMI Support is enabled none - None is enabled. annexD - Annex D is enabled lmi - LMI is enabled. annexA - Annex A is enabled. au…
1.3.6.1.4.1.449.2.1.2.1.1.5.1.9Columncdx6500frdtepT391read-writemandatoryThis parameter is the Link Integrity Verification Timer polling period. The FRI port sends status enquiry messages to network every T391/nT1 seconds.
1.3.6.1.4.1.449.2.1.2.1.1.5.1.10Columncdx6500frdtepT392read-onlymandatoryThis parameter is the polling Cycle Verification Timer period. The FRI port expects status enquiry messages every T392/nT2 seconds. This parameter must be set …
1.3.6.1.4.1.449.2.1.2.1.1.5.1.12Columncdx6500frdtepN391read-writemandatoryFull Status polling cycle. FRI port sends Full status enquiry messages to network every nN1 polls.
1.3.6.1.4.1.449.2.1.2.1.1.5.1.13Columncdx6500frdtepN392read-onlymandatoryError inactivity threshold. Number of errors during NN3 events that cause the station to be declared inactive. Should be less than or equal to nN3.
1.3.6.1.4.1.449.2.1.2.1.1.5.1.14Columncdx6500frdtepN393read-writemandatoryMonitored events count for measuring nN3. nN2 errors during nN3 events will cause the station to be declared inactive. Should be greater than nN3.
1.3.6.1.4.1.449.2.1.2.1.1.5.1.15Columncdx6500frdtepNT1read-writemandatoryThis parameter is the Link Integrity Verification Timer polling period. The FRI port sends status enquiry messages to network every T391/nT1 seconds.
1.3.6.1.4.1.449.2.1.2.1.1.5.1.16Columncdx6500frdtepNT2read-onlymandatoryThis parameter is the polling Cycle Verification Timer period. The FRI port expects status enquiry messages every T392/nT2 seconds. This parameter must be set …
1.3.6.1.4.1.449.2.1.2.1.1.5.1.17Columncdx6500frdtepNN1read-onlymandatoryFull Status polling cycle. FRI port sends Full status enquiry messages to network every nN1 polls.
1.3.6.1.4.1.449.2.1.2.1.1.5.1.18Columncdx6500frdtepNN2read-writemandatoryError inactivity threshold. Number of errors during NN3 events that cause the station to be declared inactive. Should be less than or equal to nN3.
1.3.6.1.4.1.449.2.1.2.1.1.5.1.19Columncdx6500frdtepNN3read-onlymandatoryMonitored events count for measuring nN3. nN2 errors during nN3 events will cause the station to be declared inactive. Should be greater than nN3.
1.3.6.1.4.1.449.2.1.2.1.1.5.1.20Columncdx6500frdtepHighPriorityStnread-writemandatoryThis parameter specifies a station who's PVC status has priority over all other stations when FRI same port back up is enabled. When the network reports this D…
1.3.6.1.4.1.449.2.1.2.1.1.5.1.21Columncdx6500frdtepMaxVoiceBWBitsPerSecread-writemandatoryThis parameter limits the bandwidth, in bits per sec (including overhead), for voice traffic passing through this frame relay port. A zero value disables any v…
1.3.6.1.4.1.449.2.1.2.1.1.5.1.22Columncdx6500frdtepSegSizeVoicePresentread-writemandatoryData packets to be segmented into this maximum frame size when voice is active on this port. segSize32 - 32 byte segments segSize64 - 64 byte segments segSize1…
1.3.6.1.4.1.449.2.1.2.1.1.5.1.23Columncdx6500frdtepSegSizeVoiceNotPresentread-writemandatoryData packets to be segmented into this maximum frame size when voice is not active on this port. segSize32 - 32 byte segments segSize64 - 64 byte segments segS…
1.3.6.1.4.1.449.2.1.2.1.1.5.1.24Columncdx6500frdtepInvertTXClockread-writemandatoryThis parameter specifies whether the phase of the transmit clock should be inverted. Note: This parameter is primarily for X.21 electrical interfaces. no - Don…
1.3.6.1.4.1.449.2.1.2.1.1.5.1.25Columncdx6500frdtepControlProtocolOptionsread-writemandatoryThese options control the PVC management protocol none - No option selected async - The port will send/receive asynchronous A-bit if it is performing Network s…
1.3.6.1.4.1.449.2.1.2.1.1.5.1.26Columncdx6500frdtepDiscardControlOptionsread-writemandatoryThis parameter controls the discard frame options none - No option selected debit - DE marked frames are discarded before non-DE frames
1.3.6.1.4.1.449.2.1.2.1.1.5.1.27Columncdx6500frdtepElectricalInterfaceTyperead-writemandatorySpecify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 -…
1.3.6.1.4.1.449.2.1.2.1.1.5.1.28Columncdx6500frdtepV24ElectricalInterfaceOptionread-writemandatorySpecify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal
1.3.6.1.4.1.449.2.1.2.1.1.5.1.29Columncdx6500frdtepHighSpeedElectricalInterfaceOptionread-writemandatorySpecify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
1.3.6.1.4.1.449.2.1.2.1.3Nodecdx6500PCTStationProtocolGroup
1.3.6.1.4.1.449.2.1.2.1.3.2Tablecdx6500SPCTFRDTEStationTablenot-accessiblemandatoryAll of the configuration parameters relevant to the Frame Relay DTE Station table.
1.3.6.1.4.1.449.2.1.2.1.3.2.1Rowcdx6500SPCTFRDTEStationEntrynot-accessiblemandatoryA row of Frame Realy DTE station configuration parameters.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.1Columncdx6500frdtesCfgPortNumread-onlymandatoryFR DTE Port number.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.2Columncdx6500frdtesCfgDLCIread-writemandatoryThe Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRI Port. Its valid range is 16 - 1007. It must match the DLCI confi…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.3Columncdx6500frdtesStationTyperead-writemandatoryIdentifies the type of station being configured. annexG - This station uses X.25 signaling for layer 3 bypass - This station type bypasses layer 3. There is no…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.4Columncdx6500frdtesCommInfoRateread-writemandatoryThis parameter (CIR) specifies the rate (in bits-per-second) that the Frame Relay network agrees to transfer information under congested conditions for the FRI…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.5Columncdx6500frdtesCommBurstSizeread-writemandatoryThis parameter (BC) specifies the maximum amount of data (in bits) that the Frame Relay network agrees to transfer over a time interval T = Committed Burst Siz…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.6Columncdx6500frdtesTransDelayread-writemandatoryThis parameter is the expected one-way delay through the network. This is specified in milliseconds.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.7Columncdx6500frdtesControlledModeread-writemandatoryThis parameter controls the method of congestion control: normal - congestion control is normal disable - never enter Congested State (CTRL) congested - never …
1.3.6.1.4.1.449.2.1.2.1.3.2.1.8Columncdx6500frdtesLinkAddressread-writemandatoryThe logical link address must be set to complementary values in this FRI station and its corresponding remote FRI station: dte - station to have logical DTE ad…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.9Columncdx6500frdtesPVCChannelsread-writemandatoryNumber of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.10Columncdx6500frdtesStartingPVCread-writemandatoryThis is the starting logical channel number for the Permanent Virtual Circuits on this FRI station. Not used if the number of PVCs = 0.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.11Columncdx6500frdtesSVCChannelsread-writemandatoryNumber of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as p…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.12Columncdx6500frdtesStartingSVCread-writemandatoryThis is the starting logical channel number for the Switched Virtual Circuits on this station (logical link). Not used if the number of SVCs = 0.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.13Columncdx6500frdtesInitialFrameread-writemandatorySpecify the initial frame required by other end for (logical) link startup: none - do nothing (other end initiates link-up) sabm - send SABM disc - send DISC, …
1.3.6.1.4.1.449.2.1.2.1.3.2.1.14Columncdx6500frdtesRetryTimerread-writemandatoryT1 link retry timer value in tenths of a second (e.g. 30 = 3.0 seconds).
1.3.6.1.4.1.449.2.1.2.1.3.2.1.15Columncdx6500frdtesPollTimerread-writemandatoryThis sets the time an idle link is probed for assurance of connection to the remote FRI station. 0 - disable the timer X - X is in tenths of a second (e.g. 40 …
1.3.6.1.4.1.449.2.1.2.1.3.2.1.16Columncdx6500frdtesTriesread-writemandatoryThe maximum number of attempts allowed to complete a transmission.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.17Columncdx6500frdtesFrameWinSizeread-writemandatoryFrame level window size must be set to the same value at both this FRI station and the remote FRI station.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.18Columncdx6500frdtesPacketWinSizeread-writemandatoryPacket level window size must be set to the same value at both this FRI station and the remote FRI station.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.19Columncdx6500frdtesMaxPacketSizeread-writemandatoryThis is the maximum X.25 packet size used on the station (logical link). For proper operation, this must be set to the same value at both this FRI station and …
1.3.6.1.4.1.449.2.1.2.1.3.2.1.20Columncdx6500frdtesUpperQueueread-writemandatoryThis is the maximum number of data packets a channel on this station (logical link) will queue for transmission before invoking flow control to the attached ch…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.21Columncdx6500frdtesLowerQueueread-writemandatoryThis is the number of data packets a channel on this FRI station will have queued for transmission when it releases flow control to the attached channel
1.3.6.1.4.1.449.2.1.2.1.3.2.1.22Columncdx6500frdtesRestartTimerread-writemandatoryRestart-Request timeout timer in seconds. If timer expires on this FRI station, the Restart request is sent again.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.23Columncdx6500frdtesResetTimerread-writemandatoryReset-Request timeout timer in seconds. If timer expires on this FRI station, the Reset request is sent again.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.24Columncdx6500frdtesCallTimerread-writemandatoryCall-Request timeout timer in seconds. If timer expires on this FRI station, the call is cleared.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.25Columncdx6500frdtesClearTimerread-writemandatoryClear-Request timeout timer in seconds. If timer expires on this FRI station, the Clear request is sent again.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.26Columncdx6500frdtesX25Optionsread-onlydeprecatedSelect X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CA…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.27Columncdx6500frdtesRCDestinationread-writemandatoryAll calls entering this station will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to r…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.28Columncdx6500frdtesCUGread-writemandatoryThe station may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number and separated by a comma. (e.g. 12,3…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.29Columncdx6500frdtesBillingRecordsread-writemandatoryThis controls whether billing (accounting) records will be created for calls on this FRI station. off - Billing records will not be created. on - Billing recor…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.30Columncdx6500frdtesCfgStationNumread-onlymandatoryThe number of the logical link on the line. This is the value of Sxx for routing purposes.
1.3.6.1.4.1.449.2.1.2.1.3.2.1.31Columncdx6500frdtesStnX25Optionsread-writemandatorySelect X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CA…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.32Columncdx6500frdtesStnFrameSegmenterread-writemandatoryDetermine if this station will support the Frame Segmenter Header.The Frame Segmenter should be enabled if the frame relay port is configured to pass voice tra…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.33Columncdx6500frdtesStnVoiceSVCChannelsread-writemandatoryNumber of logical voice channels used in Switched Virtual Circuits.The total number of voice and data channels on a station (logical link) should be kept as sm…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.34Columncdx6500frdtesStnVoiceCongCtrlModeread-writemandatoryThis parameter controls the method of voice congestion control: enabled - Station is forced into congestion when voice calls are detected. disabled - Station o…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.35Columncdx6500frdtesStnPeakUtilizationread-writemandatoryThe monitoring interval size specifies the time period to use when monitoring peak data link/CIR (Committed Information Rate) utilization. 0 - Disables this mo…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.36Columncdx6500frdtesStnMaxInboundQueueread-writemandatoryThis specifies the maximum number of frames from the network which may be queued in a BYPASS station. A smaller value may ve choosen for applications which exp…
1.3.6.1.4.1.449.2.1.2.1.3.2.1.37Columncdx6500frdtesStnAnnexGRateReductionread-writemandatoryThis parameter determines whether Annex G stations will invoke implicit congestion control when a link error is detected, reducing their transmitted informatio…
1.3.6.1.4.1.449.2.1.3Nodecdx6500Statistics
1.3.6.1.4.1.449.2.1.3.1Nodecdx6500StatProtocolGroup
1.3.6.1.4.1.449.2.1.3.1.1Nodecdx6500PSTPortProtocolGroup
1.3.6.1.4.1.449.2.1.3.1.1.5Tablecdx6500PPSTFRDTEPortTablenot-accessiblemandatoryAll of the statistics parameters relevant to the Frame Relay DTE Port table.
1.3.6.1.4.1.449.2.1.3.1.1.5.1Rowcdx6500PPSTFRDTEPortEntrynot-accessiblemandatoryA row of Frame Relay DTE Port statistics parameters.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.1Columncdx6500frdtepStatsPortNumread-onlymandatorySpecifies a specific port in the network diagram.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.2Columncdx6500frdtepPortStatusread-onlymandatorySpecifies the current port status. disabled - Port has been disabled. enabled - Port is operational. busyOut - Port has been busied out. up - Port is operation…
1.3.6.1.4.1.449.2.1.3.1.1.5.1.3Columncdx6500frdtepPortSpeedread-onlymandatoryMessage transmition speed in bps.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.4Columncdx6500frdtepUtilizationInread-onlymandatoryFactor determined by comparison of volume (characters per second) of data and clock rate for a specific port.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.5Columncdx6500frdtepUtilizationOutread-onlymandatoryFactor determined by comparison of volume (characters per second) of data and clock rate for a specific port.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.6Columncdx6500frdtepCharInTotalread-onlymandatoryNumber of characters received since last boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.7Columncdx6500frdtepCharOutTotalread-onlymandatoryNumber of characters transmitted since last boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.8Columncdx6500frdtepCharsInPerSecread-onlymandatoryAverage number of characters received per second.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.9Columncdx6500frdtepCharsOutPerSecread-onlymandatoryAverage number of characters transmitted per second.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.10Columncdx6500frdtepFrameInTotalread-onlymandatoryNumber of frames received since last boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.11Columncdx6500frdtepFrameOutTotalread-onlymandatoryNumber of frames transmitted since last boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.12Columncdx6500frdtepFramesInPerSecread-onlymandatoryAverage number of frames received per second.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.13Columncdx6500frdtepFramesOutPerSecread-onlymandatoryAverage number of frames transmitted per second.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.14Columncdx6500frdtepOverrunErrorsread-onlymandatoryAn input buffer overflowed and characters were discarded.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.15Columncdx6500frdtepUnderrunErrorsread-onlymandatoryNumber of errors detected since last node boot or reset of statistics.
1.3.6.1.4.1.449.2.1.3.1.1.5.1.16Columncdx6500frdtepCRCErrorsread-onlymandatoryNumber of errors detected by Cyclic Redundancy Check since last node boot reset of statistics.
1.3.6.1.4.1.449.2.1.3.1.3Nodecdx6500PSTStationProtocolGroup
1.3.6.1.4.1.449.2.1.3.1.3.2Tablecdx6500SPSTFRDTEStationTablenot-accessiblemandatoryAll of the statistics parameters relevant to the Frame Relay DTE Station (DLCI) table.
1.3.6.1.4.1.449.2.1.3.1.3.2.1Rowcdx6500SPSTFRDTEStationEntrynot-accessiblemandatoryA row of Frame Relay DTE station (DLCI) Statistics parameters.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.1Columncdx6500frdtesStatsPortNumread-onlymandatorySpecifies a specific port in the network diagram.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.2Columncdx6500frdtesStatsDLCIread-onlymandatoryData Link Connection Identifier is the unique identifier for the station on the FRI port and must match the DLCI configured on the Frame Relay networking node.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.3Columncdx6500frdtesUtilizationInread-onlymandatoryIndicates the quantity of user bytes sent down the link expressed as a percentage of the maximum number of bytes that could have been sent.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.4Columncdx6500frdtesUtilizationOutread-onlymandatoryIndicates the quantity of user bytes sent down the link expressed as a percentage of the maximum number of bytes that could have been sent.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.5Columncdx6500frdtesMaxSVCCountread-onlymandatoryMaximum number of SVCs available in the network.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.6Columncdx6500frdtesCurrentSVCCountread-onlymandatoryCurrent number of SVCs currently in use.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.7Columncdx6500frdtesCharInTotalread-onlymandatoryNumber of characters received since last node boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.8Columncdx6500frdtesCharOutTotalread-onlymandatoryNumber of characters transmitted since last node boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.9Columncdx6500frdtesCharsInPerSecread-onlymandatoryAverage number of characters received per second.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.10Columncdx6500frdtesCharsOutPerSecread-onlymandatoryAverage number of characters transmitted per second.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.11Columncdx6500frdtesPktInTotalread-onlymandatoryNumber of packets received since last node boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.12Columncdx6500frdtesPktOutTotalread-onlymandatoryNumber of packets transmitted since last node boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.13Columncdx6500frdtesPktsInPerSecread-onlymandatoryAverage number of packets received per second.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.14Columncdx6500frdtesPktsOutPerSecread-onlymandatoryAverage number of packets transmitted per second.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.15Columncdx6500frdtesPacketsQueuedread-onlymandatoryCurrent number of packets buffered since last node boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.16Columncdx6500frdtesFrameInTotalread-onlymandatoryNumber of frames received since last node boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.17Columncdx6500frdtesFrameOutTotalread-onlymandatoryNumber of frames transmitted since last node boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.18Columncdx6500frdtesFramesInPerSecread-onlymandatoryAverage number of frames received per second.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.19Columncdx6500frdtesFramesOutPerSecread-onlymandatoryAverage number of frames transmitted per second.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.20Columncdx6500frdtesInfoFramesInread-onlymandatoryData received since last node boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.21Columncdx6500frdtesInfoFramesOutread-onlymandatoryData transmitted since last node boot or statistics reset.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.22Columncdx6500frdtesRNRFramesInread-onlymandatoryUsed by the DTE or the network to request that the data flow be stopped on a particular virtual circuit.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.23Columncdx6500frdtesRNRFramesOutread-onlymandatoryUsed by the DTE or the network to request that the data flow be stopped on a particular virtual circuit.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.24Columncdx6500frdtesRRFramesInread-onlymandatoryUsed to clear the RNR request.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.25Columncdx6500frdtesRRFramesOutread-onlymandatoryUsed to clear the RNR request.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.26Columncdx6500frdtesREJFramesInread-onlymandatoryA REJ transmitted by a receiver requests retransmission of a frame, due to detection of a transmission or frame sequence error.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.27Columncdx6500frdtesREJFramesOutread-onlymandatoryA REJ transmitted by a receiver requests retransmission of a frame, due to detection of a transmission or frame sequence error.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.28Columncdx6500frdtesDataPktsInread-onlymandatoryA packet containing user information.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.29Columncdx6500frdtesDataPktsOutread-onlymandatoryA packet containing user information.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.30Columncdx6500frdtesResetStatswrite-onlymandatoryResets the specified Frame Relay station statistics. reset - Reset station statistics. noReset - Do not reset station statistics.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.31Columncdx6500frdtesBootwrite-onlymandatoryBoots the specified Frame Relay station. boot - Boot station. noBoot - Do not boot station.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.32Columncdx6500frdtesDisablewrite-onlymandatoryDisables the specified Frame Relay station. disable - Disable station. noDisable - Do not disable station.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.33Columncdx6500frdtesEnablewrite-onlymandatoryEnables the specified Frame Relay station. enable - Enable station. noEnable - Do not enable station.
1.3.6.1.4.1.449.2.1.3.1.3.2.1.34Columncdx6500frdtesStatsStationNumberread-onlymandatoryThe number of the FRI Station.
1.3.6.1.4.1.449.2.1.4Nodecdx6500Controls
Type Definitions
NameSyntaxStatusDescription
Counter16INTEGER (0..65535)
DisplayStringOCTET STRING