FRDTE-OPT-MIB
137 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC1155-SMI | Counter enterprises Gauge IpAddress mgmt NetworkAddress TimeTicks |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.449 | Nodecodex | |||
| 1.3.6.1.4.1.449.2 | NodecdxProductSpecific | |||
| 1.3.6.1.4.1.449.2.1 | Nodecdx6500 | |||
| 1.3.6.1.4.1.449.2.1.2 | Nodecdx6500Configuration | |||
| 1.3.6.1.4.1.449.2.1.2.1 | Nodecdx6500CfgProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1 | Nodecdx6500PCTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.1.5 | Tablecdx6500PCTFRDTEPortTable | not-accessible | mandatory | All of the configuration parameters relevant to the Frame Relay DTE Port table. |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1 | Rowcdx6500PCTFRDTEPortEntry | not-accessible | mandatory | A row of FRI Port configuration parameters. |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.1 | Columncdx6500frdtepCfgPortNum | read-only | mandatory | Specifies the Port number for the Frame Relay Interface port you are selecting. |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.2 | Columncdx6500frdtepConnectionType | read-write | mandatory | Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required dtr - dedicated… |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.3 | Columncdx6500frdtepClockSource | read-write | mandatory | int - internal clock source ext - external clock source extint - Internal receive and external transmit clock source (DCE only). extlp - external receive and l… |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.4 | Columncdx6500frdtepClockSpeed | read-write | mandatory | This is the speed of the port in bits per second, when using internal clocking. The highest available speed is dependent on the card type,and on the interface … |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.5 | Columncdx6500frdtepMaxStations | read-only | deprecated | This is the highest station number to be configured on this FRI port. It is used to limit the configuration of stations. |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.6 | Columncdx6500frdtepFrameSeqCounting | read-only | mandatory | Port uses normal or extended frame sequence numbering: normal - normal sequencing (modulo 8) ext - extended sequencing (modulo 128) nc - Skipped during configu… |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.7 | Columncdx6500frdtepPktSeqCounting | read-write | mandatory | Port uses normal or extended packet level sequence numbers normal - normal sequencing (Modulo 8) ext - extended sequencing (Modulo 128) nc - Skipped during con… |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.8 | Columncdx6500frdtepCtrlProtocol | read-write | mandatory | Whether ANSI T1.617 Annex D or LMI Support is enabled none - None is enabled. annexD - Annex D is enabled lmi - LMI is enabled. annexA - Annex A is enabled. au… |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.9 | Columncdx6500frdtepT391 | read-write | mandatory | This parameter is the Link Integrity Verification Timer polling period. The FRI port sends status enquiry messages to network every T391/nT1 seconds. |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.10 | Columncdx6500frdtepT392 | read-only | mandatory | This parameter is the polling Cycle Verification Timer period. The FRI port expects status enquiry messages every T392/nT2 seconds. This parameter must be set … |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.12 | Columncdx6500frdtepN391 | read-write | mandatory | Full Status polling cycle. FRI port sends Full status enquiry messages to network every nN1 polls. |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.13 | Columncdx6500frdtepN392 | read-only | mandatory | Error inactivity threshold. Number of errors during NN3 events that cause the station to be declared inactive. Should be less than or equal to nN3. |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.14 | Columncdx6500frdtepN393 | read-write | mandatory | Monitored events count for measuring nN3. nN2 errors during nN3 events will cause the station to be declared inactive. Should be greater than nN3. |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.15 | Columncdx6500frdtepNT1 | read-write | mandatory | This parameter is the Link Integrity Verification Timer polling period. The FRI port sends status enquiry messages to network every T391/nT1 seconds. |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.16 | Columncdx6500frdtepNT2 | read-only | mandatory | This parameter is the polling Cycle Verification Timer period. The FRI port expects status enquiry messages every T392/nT2 seconds. This parameter must be set … |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.17 | Columncdx6500frdtepNN1 | read-only | mandatory | Full Status polling cycle. FRI port sends Full status enquiry messages to network every nN1 polls. |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.18 | Columncdx6500frdtepNN2 | read-write | mandatory | Error inactivity threshold. Number of errors during NN3 events that cause the station to be declared inactive. Should be less than or equal to nN3. |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.19 | Columncdx6500frdtepNN3 | read-only | mandatory | Monitored events count for measuring nN3. nN2 errors during nN3 events will cause the station to be declared inactive. Should be greater than nN3. |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.20 | Columncdx6500frdtepHighPriorityStn | read-write | mandatory | This parameter specifies a station who's PVC status has priority over all other stations when FRI same port back up is enabled. When the network reports this D… |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.21 | Columncdx6500frdtepMaxVoiceBWBitsPerSec | read-write | mandatory | This parameter limits the bandwidth, in bits per sec (including overhead), for voice traffic passing through this frame relay port. A zero value disables any v… |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.22 | Columncdx6500frdtepSegSizeVoicePresent | read-write | mandatory | Data packets to be segmented into this maximum frame size when voice is active on this port. segSize32 - 32 byte segments segSize64 - 64 byte segments segSize1… |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.23 | Columncdx6500frdtepSegSizeVoiceNotPresent | read-write | mandatory | Data packets to be segmented into this maximum frame size when voice is not active on this port. segSize32 - 32 byte segments segSize64 - 64 byte segments segS… |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.24 | Columncdx6500frdtepInvertTXClock | read-write | mandatory | This parameter specifies whether the phase of the transmit clock should be inverted. Note: This parameter is primarily for X.21 electrical interfaces. no - Don… |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.25 | Columncdx6500frdtepControlProtocolOptions | read-write | mandatory | These options control the PVC management protocol none - No option selected async - The port will send/receive asynchronous A-bit if it is performing Network s… |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.26 | Columncdx6500frdtepDiscardControlOptions | read-write | mandatory | This parameter controls the discard frame options none - No option selected debit - DE marked frames are discarded before non-DE frames |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.27 | Columncdx6500frdtepElectricalInterfaceType | read-write | mandatory | Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 -… |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.28 | Columncdx6500frdtepV24ElectricalInterfaceOption | read-write | mandatory | Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal |
| 1.3.6.1.4.1.449.2.1.2.1.1.5.1.29 | Columncdx6500frdtepHighSpeedElectricalInterfaceOption | read-write | mandatory | Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable |
| 1.3.6.1.4.1.449.2.1.2.1.3 | Nodecdx6500PCTStationProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.2.1.3.2 | Tablecdx6500SPCTFRDTEStationTable | not-accessible | mandatory | All of the configuration parameters relevant to the Frame Relay DTE Station table. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1 | Rowcdx6500SPCTFRDTEStationEntry | not-accessible | mandatory | A row of Frame Realy DTE station configuration parameters. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.1 | Columncdx6500frdtesCfgPortNum | read-only | mandatory | FR DTE Port number. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.2 | Columncdx6500frdtesCfgDLCI | read-write | mandatory | The Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRI Port. Its valid range is 16 - 1007. It must match the DLCI confi… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.3 | Columncdx6500frdtesStationType | read-write | mandatory | Identifies the type of station being configured. annexG - This station uses X.25 signaling for layer 3 bypass - This station type bypasses layer 3. There is no… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.4 | Columncdx6500frdtesCommInfoRate | read-write | mandatory | This parameter (CIR) specifies the rate (in bits-per-second) that the Frame Relay network agrees to transfer information under congested conditions for the FRI… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.5 | Columncdx6500frdtesCommBurstSize | read-write | mandatory | This parameter (BC) specifies the maximum amount of data (in bits) that the Frame Relay network agrees to transfer over a time interval T = Committed Burst Siz… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.6 | Columncdx6500frdtesTransDelay | read-write | mandatory | This parameter is the expected one-way delay through the network. This is specified in milliseconds. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.7 | Columncdx6500frdtesControlledMode | read-write | mandatory | This parameter controls the method of congestion control: normal - congestion control is normal disable - never enter Congested State (CTRL) congested - never … |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.8 | Columncdx6500frdtesLinkAddress | read-write | mandatory | The logical link address must be set to complementary values in this FRI station and its corresponding remote FRI station: dte - station to have logical DTE ad… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.9 | Columncdx6500frdtesPVCChannels | read-write | mandatory | Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.10 | Columncdx6500frdtesStartingPVC | read-write | mandatory | This is the starting logical channel number for the Permanent Virtual Circuits on this FRI station. Not used if the number of PVCs = 0. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.11 | Columncdx6500frdtesSVCChannels | read-write | mandatory | Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as p… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.12 | Columncdx6500frdtesStartingSVC | read-write | mandatory | This is the starting logical channel number for the Switched Virtual Circuits on this station (logical link). Not used if the number of SVCs = 0. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.13 | Columncdx6500frdtesInitialFrame | read-write | mandatory | Specify the initial frame required by other end for (logical) link startup: none - do nothing (other end initiates link-up) sabm - send SABM disc - send DISC, … |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.14 | Columncdx6500frdtesRetryTimer | read-write | mandatory | T1 link retry timer value in tenths of a second (e.g. 30 = 3.0 seconds). |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.15 | Columncdx6500frdtesPollTimer | read-write | mandatory | This sets the time an idle link is probed for assurance of connection to the remote FRI station. 0 - disable the timer X - X is in tenths of a second (e.g. 40 … |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.16 | Columncdx6500frdtesTries | read-write | mandatory | The maximum number of attempts allowed to complete a transmission. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.17 | Columncdx6500frdtesFrameWinSize | read-write | mandatory | Frame level window size must be set to the same value at both this FRI station and the remote FRI station. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.18 | Columncdx6500frdtesPacketWinSize | read-write | mandatory | Packet level window size must be set to the same value at both this FRI station and the remote FRI station. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.19 | Columncdx6500frdtesMaxPacketSize | read-write | mandatory | This is the maximum X.25 packet size used on the station (logical link). For proper operation, this must be set to the same value at both this FRI station and … |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.20 | Columncdx6500frdtesUpperQueue | read-write | mandatory | This is the maximum number of data packets a channel on this station (logical link) will queue for transmission before invoking flow control to the attached ch… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.21 | Columncdx6500frdtesLowerQueue | read-write | mandatory | This is the number of data packets a channel on this FRI station will have queued for transmission when it releases flow control to the attached channel |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.22 | Columncdx6500frdtesRestartTimer | read-write | mandatory | Restart-Request timeout timer in seconds. If timer expires on this FRI station, the Restart request is sent again. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.23 | Columncdx6500frdtesResetTimer | read-write | mandatory | Reset-Request timeout timer in seconds. If timer expires on this FRI station, the Reset request is sent again. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.24 | Columncdx6500frdtesCallTimer | read-write | mandatory | Call-Request timeout timer in seconds. If timer expires on this FRI station, the call is cleared. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.25 | Columncdx6500frdtesClearTimer | read-write | mandatory | Clear-Request timeout timer in seconds. If timer expires on this FRI station, the Clear request is sent again. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.26 | Columncdx6500frdtesX25Options | read-only | deprecated | Select X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CA… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.27 | Columncdx6500frdtesRCDestination | read-write | mandatory | All calls entering this station will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to r… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.28 | Columncdx6500frdtesCUG | read-write | mandatory | The station may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number and separated by a comma. (e.g. 12,3… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.29 | Columncdx6500frdtesBillingRecords | read-write | mandatory | This controls whether billing (accounting) records will be created for calls on this FRI station. off - Billing records will not be created. on - Billing recor… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.30 | Columncdx6500frdtesCfgStationNum | read-only | mandatory | The number of the logical link on the line. This is the value of Sxx for routing purposes. |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.31 | Columncdx6500frdtesStnX25Options | read-write | mandatory | Select X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CA… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.32 | Columncdx6500frdtesStnFrameSegmenter | read-write | mandatory | Determine if this station will support the Frame Segmenter Header.The Frame Segmenter should be enabled if the frame relay port is configured to pass voice tra… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.33 | Columncdx6500frdtesStnVoiceSVCChannels | read-write | mandatory | Number of logical voice channels used in Switched Virtual Circuits.The total number of voice and data channels on a station (logical link) should be kept as sm… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.34 | Columncdx6500frdtesStnVoiceCongCtrlMode | read-write | mandatory | This parameter controls the method of voice congestion control: enabled - Station is forced into congestion when voice calls are detected. disabled - Station o… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.35 | Columncdx6500frdtesStnPeakUtilization | read-write | mandatory | The monitoring interval size specifies the time period to use when monitoring peak data link/CIR (Committed Information Rate) utilization. 0 - Disables this mo… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.36 | Columncdx6500frdtesStnMaxInboundQueue | read-write | mandatory | This specifies the maximum number of frames from the network which may be queued in a BYPASS station. A smaller value may ve choosen for applications which exp… |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.37 | Columncdx6500frdtesStnAnnexGRateReduction | read-write | mandatory | This parameter determines whether Annex G stations will invoke implicit congestion control when a link error is detected, reducing their transmitted informatio… |
| 1.3.6.1.4.1.449.2.1.3 | Nodecdx6500Statistics | |||
| 1.3.6.1.4.1.449.2.1.3.1 | Nodecdx6500StatProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1 | Nodecdx6500PSTPortProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.1.5 | Tablecdx6500PPSTFRDTEPortTable | not-accessible | mandatory | All of the statistics parameters relevant to the Frame Relay DTE Port table. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1 | Rowcdx6500PPSTFRDTEPortEntry | not-accessible | mandatory | A row of Frame Relay DTE Port statistics parameters. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.1 | Columncdx6500frdtepStatsPortNum | read-only | mandatory | Specifies a specific port in the network diagram. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.2 | Columncdx6500frdtepPortStatus | read-only | mandatory | Specifies the current port status. disabled - Port has been disabled. enabled - Port is operational. busyOut - Port has been busied out. up - Port is operation… |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.3 | Columncdx6500frdtepPortSpeed | read-only | mandatory | Message transmition speed in bps. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.4 | Columncdx6500frdtepUtilizationIn | read-only | mandatory | Factor determined by comparison of volume (characters per second) of data and clock rate for a specific port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.5 | Columncdx6500frdtepUtilizationOut | read-only | mandatory | Factor determined by comparison of volume (characters per second) of data and clock rate for a specific port. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.6 | Columncdx6500frdtepCharInTotal | read-only | mandatory | Number of characters received since last boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.7 | Columncdx6500frdtepCharOutTotal | read-only | mandatory | Number of characters transmitted since last boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.8 | Columncdx6500frdtepCharsInPerSec | read-only | mandatory | Average number of characters received per second. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.9 | Columncdx6500frdtepCharsOutPerSec | read-only | mandatory | Average number of characters transmitted per second. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.10 | Columncdx6500frdtepFrameInTotal | read-only | mandatory | Number of frames received since last boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.11 | Columncdx6500frdtepFrameOutTotal | read-only | mandatory | Number of frames transmitted since last boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.12 | Columncdx6500frdtepFramesInPerSec | read-only | mandatory | Average number of frames received per second. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.13 | Columncdx6500frdtepFramesOutPerSec | read-only | mandatory | Average number of frames transmitted per second. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.14 | Columncdx6500frdtepOverrunErrors | read-only | mandatory | An input buffer overflowed and characters were discarded. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.15 | Columncdx6500frdtepUnderrunErrors | read-only | mandatory | Number of errors detected since last node boot or reset of statistics. |
| 1.3.6.1.4.1.449.2.1.3.1.1.5.1.16 | Columncdx6500frdtepCRCErrors | read-only | mandatory | Number of errors detected by Cyclic Redundancy Check since last node boot reset of statistics. |
| 1.3.6.1.4.1.449.2.1.3.1.3 | Nodecdx6500PSTStationProtocolGroup | |||
| 1.3.6.1.4.1.449.2.1.3.1.3.2 | Tablecdx6500SPSTFRDTEStationTable | not-accessible | mandatory | All of the statistics parameters relevant to the Frame Relay DTE Station (DLCI) table. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1 | Rowcdx6500SPSTFRDTEStationEntry | not-accessible | mandatory | A row of Frame Relay DTE station (DLCI) Statistics parameters. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.1 | Columncdx6500frdtesStatsPortNum | read-only | mandatory | Specifies a specific port in the network diagram. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.2 | Columncdx6500frdtesStatsDLCI | read-only | mandatory | Data Link Connection Identifier is the unique identifier for the station on the FRI port and must match the DLCI configured on the Frame Relay networking node. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.3 | Columncdx6500frdtesUtilizationIn | read-only | mandatory | Indicates the quantity of user bytes sent down the link expressed as a percentage of the maximum number of bytes that could have been sent. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.4 | Columncdx6500frdtesUtilizationOut | read-only | mandatory | Indicates the quantity of user bytes sent down the link expressed as a percentage of the maximum number of bytes that could have been sent. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.5 | Columncdx6500frdtesMaxSVCCount | read-only | mandatory | Maximum number of SVCs available in the network. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.6 | Columncdx6500frdtesCurrentSVCCount | read-only | mandatory | Current number of SVCs currently in use. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.7 | Columncdx6500frdtesCharInTotal | read-only | mandatory | Number of characters received since last node boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.8 | Columncdx6500frdtesCharOutTotal | read-only | mandatory | Number of characters transmitted since last node boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.9 | Columncdx6500frdtesCharsInPerSec | read-only | mandatory | Average number of characters received per second. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.10 | Columncdx6500frdtesCharsOutPerSec | read-only | mandatory | Average number of characters transmitted per second. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.11 | Columncdx6500frdtesPktInTotal | read-only | mandatory | Number of packets received since last node boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.12 | Columncdx6500frdtesPktOutTotal | read-only | mandatory | Number of packets transmitted since last node boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.13 | Columncdx6500frdtesPktsInPerSec | read-only | mandatory | Average number of packets received per second. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.14 | Columncdx6500frdtesPktsOutPerSec | read-only | mandatory | Average number of packets transmitted per second. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.15 | Columncdx6500frdtesPacketsQueued | read-only | mandatory | Current number of packets buffered since last node boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.16 | Columncdx6500frdtesFrameInTotal | read-only | mandatory | Number of frames received since last node boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.17 | Columncdx6500frdtesFrameOutTotal | read-only | mandatory | Number of frames transmitted since last node boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.18 | Columncdx6500frdtesFramesInPerSec | read-only | mandatory | Average number of frames received per second. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.19 | Columncdx6500frdtesFramesOutPerSec | read-only | mandatory | Average number of frames transmitted per second. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.20 | Columncdx6500frdtesInfoFramesIn | read-only | mandatory | Data received since last node boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.21 | Columncdx6500frdtesInfoFramesOut | read-only | mandatory | Data transmitted since last node boot or statistics reset. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.22 | Columncdx6500frdtesRNRFramesIn | read-only | mandatory | Used by the DTE or the network to request that the data flow be stopped on a particular virtual circuit. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.23 | Columncdx6500frdtesRNRFramesOut | read-only | mandatory | Used by the DTE or the network to request that the data flow be stopped on a particular virtual circuit. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.24 | Columncdx6500frdtesRRFramesIn | read-only | mandatory | Used to clear the RNR request. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.25 | Columncdx6500frdtesRRFramesOut | read-only | mandatory | Used to clear the RNR request. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.26 | Columncdx6500frdtesREJFramesIn | read-only | mandatory | A REJ transmitted by a receiver requests retransmission of a frame, due to detection of a transmission or frame sequence error. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.27 | Columncdx6500frdtesREJFramesOut | read-only | mandatory | A REJ transmitted by a receiver requests retransmission of a frame, due to detection of a transmission or frame sequence error. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.28 | Columncdx6500frdtesDataPktsIn | read-only | mandatory | A packet containing user information. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.29 | Columncdx6500frdtesDataPktsOut | read-only | mandatory | A packet containing user information. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.30 | Columncdx6500frdtesResetStats | write-only | mandatory | Resets the specified Frame Relay station statistics. reset - Reset station statistics. noReset - Do not reset station statistics. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.31 | Columncdx6500frdtesBoot | write-only | mandatory | Boots the specified Frame Relay station. boot - Boot station. noBoot - Do not boot station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.32 | Columncdx6500frdtesDisable | write-only | mandatory | Disables the specified Frame Relay station. disable - Disable station. noDisable - Do not disable station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.33 | Columncdx6500frdtesEnable | write-only | mandatory | Enables the specified Frame Relay station. enable - Enable station. noEnable - Do not enable station. |
| 1.3.6.1.4.1.449.2.1.3.1.3.2.1.34 | Columncdx6500frdtesStatsStationNumber | read-only | mandatory | The number of the FRI Station. |
| 1.3.6.1.4.1.449.2.1.4 | Nodecdx6500Controls |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Counter16 | INTEGER (0..65535) | ||
| DisplayString | OCTET STRING |