MIB Viewer

FSC-SERVERCONTROL2-MIB

577 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1Nodeenterprises
1.3.6.1.4.1.231Nodesni
1.3.6.1.4.1.231.2NodesniProductMibs
1.3.6.1.4.1.231.2.10NodesniExtensions
1.3.6.1.4.1.231.2.10.2NodesniServerMgmt
1.3.6.1.4.1.231.2.10.2.1NodesniInventory
1.3.6.1.4.1.231.2.10.2.2NodesniCommon
1.3.6.1.4.1.231.2.10.2.2.10NodefscServerControl2
1.3.6.1.4.1.231.2.10.2.2.10.1Nodesc2AgentInfo
1.3.6.1.4.1.231.2.10.2.2.10.1.1Scalarsc2AgentIdread-onlymandatoryAgent identification string
1.3.6.1.4.1.231.2.10.2.2.10.1.2Scalarsc2AgentCompanyread-onlymandatoryAgent's company name (e.g. Fujitsu Technology Solutions)
1.3.6.1.4.1.231.2.10.2.2.10.1.3Scalarsc2AgentVersionread-onlymandatoryAgent's version string (e.g. 1.05)
1.3.6.1.4.1.231.2.10.2.2.10.1.4Scalarsc2AgentBuildread-onlymandatoryCompilation time and date of agent program
1.3.6.1.4.1.231.2.10.2.2.10.1.5Scalarsc2AgentWriteAllowedread-onlymandatoryDefines whether writable objects can be written (except shutdown/power-off operations)
1.3.6.1.4.1.231.2.10.2.2.10.1.6Scalarsc2AgentShutdownAllowedread-onlymandatoryDefines whether shutdown/power-off objects can be written
1.3.6.1.4.1.231.2.10.2.2.10.2Nodesc2UnitInformation
1.3.6.1.4.1.231.2.10.2.2.10.2.1Scalarsc2LocalServerUnitIdread-onlymandatoryUnit identifier number of the local server (usually is ID 1). This ID can be used as index into the sc2Units table.
1.3.6.1.4.1.231.2.10.2.2.10.2.2Scalarsc2NumberUnitsread-onlymandatoryNumber of available units (size of sc2Units table).
1.3.6.1.4.1.231.2.10.2.2.10.2.3Tablesc2UnitTablenot-accessiblemandatoryDescription of all units in this MIB
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1Rowsc2Unitsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.1Columnsc2uUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.2Columnsc2UnitClassread-onlymandatoryUnit classification (type)
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.3Columnsc2UnitCabinetNrread-onlymandatoryUnit cabinet number (used for addressing storage extension cabinets or server blades). The ID of the local server is usually 0.
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.4Columnsc2UnitDesignationread-onlymandatoryUnit designation / housing type (e.g. 'H200R')
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.5Columnsc2UnitModelNameread-onlymandatoryUnit model name (e.g. 'PRIMERGY RX100')
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.6Columnsc2UnitManufacturerread-onlymandatoryUnit manufacturer name (e.g. 'Fujitsu Technology Solutions')
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.7Columnsc2UnitSerialNumberread-onlymandatoryUnit serial number (e.g. 'YBCL123456')
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.8Columnsc2UnitLocationread-onlymandatoryUnit location string (e.g. 'ServerCenter Room 17, Rack 9')
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.9Columnsc2UnitContactread-onlymandatoryUnit contact name (e.g. 'Mr. Bond')
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.10Columnsc2UnitAdminURLread-onlymandatoryURL of administration HTML interface (e.g. 'http://MyServer/admin')
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.11Columnsc2FrontDoorStatusread-onlymandatoryStatus describing whether the front door is open or closed
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.12Columnsc2HousingOpenStatusread-onlymandatoryStatus describing whether the housing is open or closed
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.13Columnsc2MsgLogLanguagesread-onlymandatorySupported languages of text message log (comma-seperated list of decimal language codes, see sc2MessageTextLogTable). e.g. '1031,1033' means German and English…
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.14Columnsc2UnitWorldWideNameread-onlymandatoryUnit World Wide Name. A 64-bit sized address for storage devices (e.g. '6661E2B0A00B88FB')
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.15Columnsc2RemcsIdread-onlymandatoryREMCS system identification string (binary data): Format of Fujitsu REMCS ID (40byte) Format = TTMMMMMMMMMMMMmmmmmmmmmmmmCCnnnnnnnnnnnn TT : 2byte : Type ID fo…
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.16Columnsc2AssetTagread-onlymandatoryCustomer specific asset tag (40 bytes)
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.17Columnsc2MsgLogAvailableread-onlymandatoryReplies whether a message log is available on this unit
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.18Columnsc2ManagementIpAddressread-onlymandatoryIPv4 address of the server for management purpose with PRIMEQUEST systems only. This is the interface address for managing a server by external management clie…
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.19Columnsc2HasUefiFirmwareread-onlymandatoryReplies whether the system is equipped with UEFI firmware
1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.20Columnsc2ManagementIpAddressV6read-onlymandatoryIPv6 address of the server for management purpose with PRIMEQUEST systems only. This is the interface address for managing a server by external management clie…
1.3.6.1.4.1.231.2.10.2.2.10.2.4Scalarsc2UnitTableUpdateCountread-onlymandatoryCounter defining the update revision of the unit table. This counter is incremented with every table contents change/update.
1.3.6.1.4.1.231.2.10.2.2.10.2.5Tablesc2UnitParentTablenot-accessiblemandatoryParent-child relationship of all units: list the parent of all available units. Only units that have a parent are listed in this table.
1.3.6.1.4.1.231.2.10.2.2.10.2.5.1Rowsc2UnitParentsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.1Columnsc2pUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.2Columnsc2ParentUnitread-onlymandatoryUnit identifier of this unit's parent
1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.3Columnsc2ParentUnitClassread-onlymandatoryParent unit classification (type). This is the same value as in sc2Units table, but can be used for easy class detection.
1.3.6.1.4.1.231.2.10.2.2.10.2.6Tablesc2UnitChildTablenot-accessiblemandatoryParent-child relationship of all units: list all children of all available units. Only units that have children are listed in this table.
1.3.6.1.4.1.231.2.10.2.2.10.2.6.1Rowsc2UnitChildsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.1Columnsc2cUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.2Columnsc2cChildNrread-onlymandatoryChild number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.3Columnsc2ChildUnitread-onlymandatoryChild unit
1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.4Columnsc2ChildUnitClassread-onlymandatoryUnit classification (type). This is the same value as in sc2Units table, but can be used for easy class detection.
1.3.6.1.4.1.231.2.10.2.2.10.3Nodesc2Management
1.3.6.1.4.1.231.2.10.2.2.10.3.1Tablesc2ManagementNodeTablenot-accessiblemandatorySNMP management node addresses (how to address the units)
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1Rowsc2ManagementNodesnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.1Columnsc2mnUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.2Columnsc2mnNodeNrread-onlymandatoryManagement node address number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.3Columnsc2UnitNodeIfTyperead-onlymandatoryManagement node interface type
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.4Columnsc2UnitNodeAddressread-onlymandatoryManagement node address (e.g. 192.168.0.100)
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.5Columnsc2UnitNodeIpNetmaskread-onlymandatoryManagement node address (e.g. 255.255.255.128)
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.6Columnsc2UnitNodeGatewayread-onlymandatoryManagement node address (e.g. 192.168.0.126)
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.7Columnsc2UnitNodeNameread-onlymandatoryManagement node name (DNS name, e.g. apollo.ts.fujitsu.com)
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.8Columnsc2UnitNodeClassread-onlymandatoryManagement node class: primary: local operating system interface secondary: local management controller LAN interface management-blade: management blade interf…
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.9Columnsc2UnitNodeMacAddressread-onlymandatoryManagement node hardware (MAC) address
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.10Columnsc2UnitNodeUseDHCPread-onlymandatoryManagement node uses DHCP to obtain its address
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.11Columnsc2UnitNodeControllerTyperead-onlymandatoryThe type of the remote management controller (for identification), like 'RSB', 'RSB S2', 'RSB S2 LP'... These names will not be changed if defined once.
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.12Columnsc2UnitNodeControllerModelread-onlymandatoryThe model name of the remote management controller (for displaying), like 'Remote Service Board', 'RemoteView Service Board S2'... This name should not be used…
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.13Columnsc2UnitNodeControllerFWVersionread-onlymandatoryThe FW version of the remote management controller
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.14Columnsc2UnitNodeControllerStorageread-onlymandatoryStatus of the controller specific external storage used for the system management.
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.15Columnsc2UnitNodeSNMPEnabledread-onlymandatorySNMP interface is enabled at management node
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.16Columnsc2UnitNodeCIMEnabledread-onlymandatoryCIM protocol is enabled at management node
1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.17Columnsc2UnitNodeRemoteIPMIEnabledread-onlymandatoryRemote IPMI is enabled at management node
1.3.6.1.4.1.231.2.10.2.2.10.3.2Scalarsc2NodeTableUpdateCountread-onlymandatoryCounter defining the update revision of the management node table. This counter is incremented with every table contents change/update.
1.3.6.1.4.1.231.2.10.2.2.10.3.3Scalarsc2ManagementChannelTyperead-onlymandatoryThe type of the management channel currently used (this MIB instance).
1.3.6.1.4.1.231.2.10.2.2.10.3.4Tablesc2ManagementProcessorTablenot-accessiblemandatorySystem management service processors
1.3.6.1.4.1.231.2.10.2.2.10.3.4.1Rowsc2ManagementProcessorsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.1Columnsc2spUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.2Columnsc2spProcessorNrread-onlymandatoryService processor number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.3Columnsc2spModelNameread-onlymandatoryService processor model name
1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.4Columnsc2spFirmwareVersionread-onlymandatoryService processor firmware version / revision
1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.5Columnsc2spBatteryStatusread-onlymandatoryService processor backup battery status
1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.6Columnsc2spBatteryDischargeTimeread-onlymandatoryMaximum time (in seconds) this backup battery can discharged, after that a shutdown will be performed (-1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.7Columnsc2spTimeOnBatteryread-onlymandatoryTime (in seconds) the service processor is running on battery since power fail (will be cleared on power recovery)
1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.8Columnsc2spDoBatteryChargeCycleread-writemandatoryPerform a discharge/charge cycle on the backup battery by writing a non-zero value. Reading this object just returns the value 0.
1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.9Columnsc2spBatteryChargeLevelread-onlymandatoryReads the current charge level of the rechargeable battery (in percent of the maximum capacity).
1.3.6.1.4.1.231.2.10.2.2.10.3.5Tablesc2ManagedUpsNodeTablenot-accessiblemandatoryUPS nodes managed by the units
1.3.6.1.4.1.231.2.10.2.2.10.3.5.1Rowsc2ManagedUpsNodesnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.1Columnsc2upsUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.2Columnsc2upsNrread-onlymandatoryUPS number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.3Columnsc2upsVendorNameread-onlymandatoryUPS vendor name
1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.4Columnsc2upsModelNameread-onlymandatoryUPS model name
1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.5Columnsc2upsMgmtAddressread-onlymandatoryUPS management interface target address (represented as string; may contain an IP V4 address, IP V6 address or a URL)
1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.6Columnsc2upsMibRootread-onlymandatoryUPS MIB root OID; specifies the root OID of the MIB to be used to query UPS via SNMP (empty string if no SNMP agent available)
1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.7Columnsc2upsSnmpCommunityread-onlymandatoryUPS SNMP community name (empty string if no SNMP agent available)
1.3.6.1.4.1.231.2.10.2.2.10.3.6Scalarsc2UpsNodeTableUpdateCountread-onlymandatoryCounter defining the update revision of the UPS node table. This counter is incremented with every table contents change/update.
1.3.6.1.4.1.231.2.10.2.2.10.4Nodesc2ServerInformation
1.3.6.1.4.1.231.2.10.2.2.10.4.1Tablesc2ServerTablenot-accessiblemandatoryTable containing information about the available servers
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1Rowsc2Serversnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.1Columnsc2srvUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.2Columnsc2srvPhysicalMemoryread-onlymandatorySize of physical main memory installed (MBytes)
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.3Columnsc2srvLastBootResultread-onlymandatoryResult of last system boot
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.4Columnsc2srvCurrentBootStatusread-onlymandatoryStatus of the current boot
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.5Columnsc2srvShutdownCommandread-writemandatoryShutdown the server and switch off or reset; a delay (see object below) can be defined before the command is being executed; when reading that value, always un…
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.6Columnsc2srvShutdownDelayread-writemandatoryDelay time (seconds) the agent waits before executing the shutdown command (see previous command). 0 = immediate action, no delay -1 = unknown (delay not suppo…
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.7Columnsc2srvUUIDread-onlymandatoryUniversal Unique ID (UUID) number (as specified in RFC 4122; shown in network byte order, big-endian) - this is a world-wide unique ID number of the server. Ca…
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.8Columnsc2srvPhysicalMemoryOsread-onlymandatorySize of physical main memory available to the operating system (MBytes). This value is similar to 'sc2srvPhysicalMemory', but may be less if the system has mir…
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.9Columnsc2srvUUIDWireFormatread-onlymandatoryUniversal Unique ID (UUID) number (shown in the wire format; little-endian for the first three fields, as consistently used in the PC industry) - this is a wor…
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.10Columnsc2srvOsPlatformread-onlymandatoryReports about the current operating system platform (x86, x64)
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.11Columnsc2srvBiosVersionread-onlymandatorySystem BIOS version
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.12Columnsc2srvHasEncryptedPartitionsread-onlymandatorySpecifies whether encrypted file systems (e.g. by Windows BitLocker) are used (may prevent from BIOS updates)
1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.13Columnsc2srvTrustedExecutionTechnologyEnabledread-onlymandatorySpecifies whether Intel Trusted Execution Technology (TXT) is enabled (may prevent from BIOS updates)
1.3.6.1.4.1.231.2.10.2.2.10.4.2Tablesc2UnitPowerOnOffTablenot-accessiblemandatoryUnit power-on and -off information
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1Rowsc2UnitPowerOnOffnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.1Columnsc2ooUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.2Columnsc2PowerOnOffStatusread-onlymandatoryCurrent power on/off status
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.3Columnsc2LastPowerOffSourceread-onlymandatoryReason why the system was switched off last time
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.4Columnsc2LastPowerOnSourceread-onlymandatorySource the system was switched on from
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.5Columnsc2LastPowerOnTimeread-onlymandatoryTime and date (UTC) the system was booted (seconds since 1/1/1970; 0 = unknown or not available)
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.6Columnsc2PowerOnCountsread-onlymandatoryTells how often the server was switched on in its life (0 = unknown or not available)
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.7Columnsc2PowerOnDurationread-onlymandatoryTells how long the system has stayed ON in its life (in seconds; 0 = unknown or not available)
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.8Columnsc2PowerOffDurationread-onlymandatoryTells how long the system has stayed OFF in its life (in seconds; 0 = unknown or not available)
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.9Columnsc2PowerFailRecoveryread-onlymandatoryAction on AC power recovery after AC has failed. not-available(2) : function not available, behavior is hardware-defined. as-before(3) : server gets the same p…
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.10Columnsc2PowerCommandread-writemandatorySwitch the unit on or off; mainly used for extension cabinets; argument tells what kind of action: on: switch power on off: switch power off power-cycle: switc…
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.11Columnsc2PowerSupplyRedundancyread-onlymandatorySpecifies whether the power supply system contains redundant power supplies and whether redundancy is available
1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.12Columnsc2PowerSupplyMatchStatusread-onlymandatoryStatus of power supply matching - 'ok' if power supplies do not mismatch
1.3.6.1.4.1.231.2.10.2.2.10.4.3Tablesc2PerformanceTablenot-accessiblemandatoryServer performance and utilisation information (Obsolete! Please use sc2PerformanceValueTable!)
1.3.6.1.4.1.231.2.10.2.2.10.4.3.1Rowsc2Performancenot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.1Columnsc2perfUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.2Columnsc2perfNrread-onlymandatoryServer performance entry number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.3Columnsc2PerformanceTyperead-onlymandatoryServer performance object type (description see below)
1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.4Columnsc2PerformanceObjectNrread-onlymandatoryServer performance object number (0..n; for types with multiple objects)
1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.5Columnsc2PerformanceNameread-onlymandatoryName (short description) of the performance value (e.g. 'CPU1'). Can be used for displaying a list of performance values in the management frontend.
1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.6Columnsc2PerformanceValueread-onlymandatoryServer performance value (value interpretation depending on type; 0xffffffff = unknown): cpu: Load of a single CPU in percent cpu-overall: Overall CPU load in …
1.3.6.1.4.1.231.2.10.2.2.10.4.4Tablesc2TimerOnOffTablenot-accessiblemandatoryPower on/off timer table
1.3.6.1.4.1.231.2.10.2.2.10.4.4.1Rowsc2TimerOnOffnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.1Columnsc2tooUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.2Columnsc2tooDayOfWeekread-onlymandatoryDay of the week the times should act upon (index); 1=Sunday, 2=Monday...
1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.3Columnsc2OnTimeread-writemandatoryTime the system should be switched on (by the real-time clock; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 are allowed.
1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.4Columnsc2OffTimeread-writemandatoryTime the system should be switched off (by the real-time clock of software; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 a…
1.3.6.1.4.1.231.2.10.2.2.10.4.5Tablesc2PowerMonitoringTablenot-accessiblemandatoryPower monitoring table
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1Rowsc2PowerMonitoringnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.1Columnsc2pmUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.2Columnsc2pmCurrentPowerMonitoringAvailableread-onlymandatoryPower monitoring and control available on this server: true: Power monitoring and power control is available false: Power monitoring and power control is not a…
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.3Columnsc2pmCurrentPowerMonitoringEnabledread-onlymandatoryPower monitoring enable value: true: Power monitoring and data gathering is enabled false: Power monitoring and data gathering is disabled or not available
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.4Columnsc2pmNominalPowerConsumptionread-onlymandatoryNominal (maximum) value of the system's power consumption (in Watts; -1 if value not available)
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.5Columnsc2pmCurrentPowerConsumptionread-onlymandatoryCurrent value of the system's power consumption (in Watts; -1 if value not available)
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.6Columnsc2pmCurrentPowerControlread-onlymandatoryPower mode control value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management …
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.7Columnsc2pmPowerLimitStatusread-onlymandatoryPower limitation status (valid if power control = limited) ok: power consumption is within specified range warning: power consumption is above warning threshol…
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.8Columnsc2pmPowerLimitThresholdread-onlymandatoryMaximum limit value of the system's power consumption (in Watts; -1 if value not available; only valid if limiting enabled)
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.9Columnsc2pmPowerLimitWarningread-onlymandatoryWarning limit level (in percent of the maximum limit threshold; 0 if value not available; only valid if limiting enabled)
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.10Columnsc2pmRedundancyCritLevelread-onlymandatoryUpper critical power consumption level (in Watts; -1 if value not available); power supply redundancy lost if level is exceeded
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.11Columnsc2pmPowerControlModeread-onlymandatoryConfigured power control mode value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard …
1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.12Columnsc2pmPowerDisplayUnitread-onlymandatoryConfigurd unit for the display of power consumption values: Watt: Power consumption values are displayed in Watts Btu/h: Power consumption values are displyed …
1.3.6.1.4.1.231.2.10.2.2.10.4.6Tablesc2UtilizationHistoryTablenot-accessiblemandatoryUtilization history table (for power consumption); table only contains existing values (no values for non-existing values)
1.3.6.1.4.1.231.2.10.2.2.10.4.6.1Rowsc2UtilizationHistorynot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.1Columnsc2uthUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.2Columnsc2uthEntityread-onlymandatoryUtilization value entity; describes what kind of value to be requested: powerConsumptionDay: power consumption values of the last 24 hours; one value (Watts) p…
1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.3Columnsc2uthTimeStampread-onlymandatoryTime stamp of the currenty history entry (time_t = seconds since 1/1/1970, 0:00 AM as GMT)
1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.4Columnsc2uthHardwareUUIDread-onlymandatoryUUID of the hardware instance that delivered the value (from object sc2srvUUID); may change if an installation is migrated to another hardware (e.g. in blade e…
1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.5Columnsc2uthAverageValueread-onlymandatoryAverage value (in Watts) within the monitored time period (minute, hour, day)
1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.6Columnsc2uthMinValueread-onlymandatoryMinimum (lowest) value within the monitored time period
1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.7Columnsc2uthMaxValueread-onlymandatoryMaximum (highest) value within the monitored time period
1.3.6.1.4.1.231.2.10.2.2.10.4.7Tablesc2PowerSourceInformationTablenot-accessiblemandatoryPower source information table
1.3.6.1.4.1.231.2.10.2.2.10.4.7.1Rowsc2PowerSourceInformationnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.1Columnsc2psiUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.2Columnsc2psiPowerSourceTyperead-onlymandatorySystem input power source type (e.g. 'AC', 'DC')
1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.3Columnsc2psiPowerSourcePhaseread-onlymandatorySystem input phase of power source.
1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.4Columnsc2psiPowerSourceVoltageread-onlymandatorySystem nominal input voltage of power source (in Volts; -1 if value not available).
1.3.6.1.4.1.231.2.10.2.2.10.4.8Tablesc2VirtualIoManagerTablenot-accessiblemandatoryVirtual I/O Manager (VIOM) information table
1.3.6.1.4.1.231.2.10.2.2.10.4.8.1Rowsc2VirtualIoManagernot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.1Columnsc2viomUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.2Columnsc2viomCurrentManagerIdread-onlymandatoryIdentification string of the VIOM manager that currently manages this server
1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.3Columnsc2viomEnabledread-onlymandatoryTrue if the server is enabled for VIOM
1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.4Columnsc2viomBiosSupportread-onlymandatoryTrue if the BIOS supports VIOM
1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.5Columnsc2viomConnectionStatusread-onlymandatoryThe connection status for VIOM - bit field: Bit 0 - waiting for VIOM table Bit 1 - waiting for inventory table Bit 2 - waiting for external power-on event
1.3.6.1.4.1.231.2.10.2.2.10.4.9Tablesc2PowerSupplyRedundancyConfigurationTablenot-accessiblemandatoryPower Supply redundancy configuration table
1.3.6.1.4.1.231.2.10.2.2.10.4.9.1Rowsc2PowerSupplyRedundancyConfigurationnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.1Columnsc2PSRedUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.2Columnsc2PSRedundancyModeread-onlymandatoryConfigured power supply redundancy mode; configured in Server Configuration
1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.3Columnsc2PSRedundancyModeConfigread-onlymandatoryConfiguration of number required power supplies for the different redundancy modes specified in sc2PSRedundancyMode: no-redundancy(2): no redundancy required r…
1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.4Columnsc2PSRedundancyRequiredPowerSuppliesread-onlymandatoryNumber of power supplies required for configured redundancy mode
1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.5Columnsc2PSRedundancyPopulatedPowerSuppliesread-onlymandatoryNumber of power supplies populated for configured redundancy mode
1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.6Columnsc2PSRedundancyConfigurationStatusread-onlymandatoryStatus of the redundancy configuration; reports the status about whether enough power supplies are installed to operate at the configured redundancy mode
1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.7Columnsc2PSRedundancyThresholdStatusread-onlymandatoryStatus of redundancy threshold; reports the status about whether the actual power consumption exceeds the maximum power consumption level for the configured re…
1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.8Columnsc2PSRedundancyStatusread-onlymandatoryStatus of power supply redundancy; similar to sc2PowerSupplyRedundancy, but with additional status evaluation according to the power supply redundancy configur…
1.3.6.1.4.1.231.2.10.2.2.10.4.10Tablesc2PerformanceValueTablenot-accessiblemandatoryServer performance and utilisation values
1.3.6.1.4.1.231.2.10.2.2.10.4.10.1Rowsc2PerformanceValuesnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.1Columnsc2PerfValUnitIdread-onlymandatoryUnit identifier (index, 1..n). For performacne values on local system use 1!
1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.2Columnsc2PerfValTyperead-onlymandatoryServer performance object type (description see below)
1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.3Columnsc2PerfValObjectNrread-onlymandatoryServer performance object number (1..n; for types with multiple objects)
1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.4Columnsc2PerfValNameread-onlymandatoryName (short description) of the performance value (e.g. 'CPU1'). Can be used for displaying a list of performance values in the management frontend.
1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.5Columnsc2PerfValCurrentValueread-onlymandatoryServer performance value (value interpretation depending on type; 0xffffffff = unknown): physicalMemoryUsageMb: Physical memory usage in MBytes physicalMemoryU…
1.3.6.1.4.1.231.2.10.2.2.10.5Nodesc2Environment
1.3.6.1.4.1.231.2.10.2.2.10.5.1Tablesc2TemperatureSensorTablenot-accessiblemandatoryTemperature sensors
1.3.6.1.4.1.231.2.10.2.2.10.5.1.1Rowsc2TemperatureSensorsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.1Columnsc2tempUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.2Columnsc2tempSensorNrread-onlymandatoryTemperature sensor number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.3Columnsc2tempSensorDesignationread-onlymandatoryTemperature sensor designation (e.g. TEMP-PS1)
1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.4Columnsc2tempSensorIdentifierread-onlymandatoryTemperature sensor identification string (e.g. TEMP-RSB1)
1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.5Columnsc2tempSensorStatusread-onlymandatoryStatus of the temperature sensor
1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.6Columnsc2tempCurrentTemperatureread-onlymandatoryCurrent temperature at this sensor (degrees Celsius; 0 if unknown or sensor failed)
1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.7Columnsc2tempWarningLevelread-onlymandatoryMaximum temperature - warning level (degrees Celsius; 0 if unknown or undefined)
1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.8Columnsc2tempCriticalLevelread-onlymandatoryMaximum temperature - critical level (degrees Celsius; 0 if unknown or undefined), system shutdown may occur if this level is exceeded
1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.9Columnsc2tempCriticalReactionread-writemandatoryReaction if temperature exceeds the critical level (the value unknown(1) cannot be set)
1.3.6.1.4.1.231.2.10.2.2.10.5.2Tablesc2FanTablenot-accessiblemandatoryCooling devices (fans, liquid cooling pumps)
1.3.6.1.4.1.231.2.10.2.2.10.5.2.1Rowsc2Fansnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.1Columnsc2fanUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.2Columnsc2fanNrread-onlymandatoryCooling device number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.3Columnsc2fanDesignationread-onlymandatoryCooling device designation (e.g. FAN-PS1)
1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.4Columnsc2fanIdentifierread-onlymandatoryCooling device identification string (e.g. FAN-1-POWERSUPPLY)
1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.5Columnsc2fanStatusread-onlymandatoryStatus of the cooling device
1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.6Columnsc2fanCurrentSpeedread-onlymandatoryCurrent cooling device speed (revolutions per minute; 0 if unknown or failed)
1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.7Columnsc2fanQualityread-onlymandatoryQuality of cooling device (in percent of nominal speed - measured at full speed)
1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.8Columnsc2fanFailReactionread-writemandatoryReaction if the cooling device fails (the value unknown(1) cannot be set)
1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.9Columnsc2fanFailShutdownDelayread-writemandatoryDelay time (in seconds) when shutdown should commit on cooling device fail (if shutdown-and-off is configured; 0 = immediately, -1 = unknown, cannot be set)
1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.10Columnsc2fanCoolingDeviceTyperead-onlymandatoryType of cooling device (whether fan or liquid cooling pump) fan(2): fan liquid(3): liquid cooling pump
1.3.6.1.4.1.231.2.10.2.2.10.5.3Tablesc2AirflowTablenot-accessiblemandatoryExhaust airflow volume table
1.3.6.1.4.1.231.2.10.2.2.10.5.3.1Rowsc2Airflownot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.1Columnsc2afUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.2Columnsc2afExhaustAirflowVolumeread-onlymandatorySystem exhaust airflow volume ('-1' if value not available)
1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.3Columnsc2afExhaustAirflowVolumeUnitread-onlymandatorySystem exhaust airflow volume unit (e.g. 'cbm/h', 'ccm/min', ...)
1.3.6.1.4.1.231.2.10.2.2.10.6Nodesc2Hardware
1.3.6.1.4.1.231.2.10.2.2.10.6.1Tablesc2SystemBoardTablenot-accessiblemandatorySystem board (main board) information
1.3.6.1.4.1.231.2.10.2.2.10.6.1.1Rowsc2SystemBoardnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.1Columnsc2sbUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.2Columnsc2sbBoardNrread-onlymandatorySystem board number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.3Columnsc2SystemBoardModelNameread-onlymandatoryModel name (e.g. 'D1297')
1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.4Columnsc2SystemBoardProductNumberread-onlymandatoryProduct number (may be identical to ModelName)
1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.5Columnsc2SystemBoardRevisionread-onlymandatoryRevision string (e.g. 'WGS1 GS3')
1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.6Columnsc2SystemBoardSerialNumberread-onlymandatorySerial number (not available for all boards)
1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.7Columnsc2SystemBoardDesignationread-onlymandatoryDesignation (important when multiple system boards are available)
1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.8Columnsc2SystemBoardSDCardSlotPresentread-onlymandatorySystem board contains SD card slot
1.3.6.1.4.1.231.2.10.2.2.10.6.2Tablesc2PowerSupplyTablenot-accessiblemandatoryPower supplies
1.3.6.1.4.1.231.2.10.2.2.10.6.2.1Rowsc2PowerSupplynot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.1Columnsc2psUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.2Columnsc2psPowerSupplyNrread-onlymandatoryPower supply (bay) number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.3Columnsc2PowerSupplyDesignationread-onlymandatoryPower supply designation (e.g. PS1)
1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.4Columnsc2PowerSupplyIdentifierread-onlymandatoryPower supply identification string (e.g. PS1)
1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.5Columnsc2PowerSupplyStatusread-onlymandatoryPower supply status
1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.6Columnsc2psPowerSupplyLoadread-onlymandatoryActual power supply output load in Watts (0 = not available)
1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.7Columnsc2psPowerSupplyNominalread-onlymandatoryNominal power supply output load in Watts (0 = not available), the maximum value the power supply can provide
1.3.6.1.4.1.231.2.10.2.2.10.6.3Tablesc2VoltageTablenot-accessiblemandatoryVoltages - all voltage values are in 1/100th Volts; a value of 330 means 3.30 Volts (0xffffffff = unknown)
1.3.6.1.4.1.231.2.10.2.2.10.6.3.1Rowsc2Voltagesnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.1Columnsc2voUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.2Columnsc2voSensorNrread-onlymandatoryVoltage sensor number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.3Columnsc2VoltageDesignationread-onlymandatoryVoltage designation string (e.g. 12V, 3V3, ...)
1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.4Columnsc2VoltageStatusread-onlymandatoryVoltage status not-available(2): no voltage available (e.g. CPU voltage on empty CPU socket) ok(3): voltage value is in normal range too-low(4): voltage value …
1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.5Columnsc2VoltageCurrentValueread-onlymandatoryVoltage current value (in mV; 0xFFFFFFFF = unknown; negative voltages are reported as negative values: -1770 (0xFFFFF916) means -1.77 Volts)
1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.6Columnsc2VoltageNominalValueread-onlymandatoryVoltage nominal value (in mV; -1 = unknown; negative voltages are reported as negative values)
1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.7Columnsc2VoltageMinimumLevelread-onlymandatoryVoltage minimum level (in mV; -1 = unknown; negative voltages are reported as negative values)
1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.8Columnsc2VoltageMaximumLevelread-onlymandatoryVoltage maximum level (in mV; -1 = unknown; negative voltages are reported as negative values)
1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.9Columnsc2VoltageCurrentLoadread-onlymandatoryCurrent output load on this voltage line, in percent of the maximum load (0xFFFFFFFF = unknown)
1.3.6.1.4.1.231.2.10.2.2.10.6.4Tablesc2CPUTablenot-accessiblemandatoryCPU description table
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1Rowsc2CPUsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.1Columnsc2cpuUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.2Columnsc2cpuNrread-onlymandatoryCPU (socket) number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.3Columnsc2cpuDesignationread-onlymandatoryCPU designation (e.g. CPU-2)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.4Columnsc2cpuStatusread-onlymandatoryCPU status: unknown(1): CPU status could not be evaluated not-present(2): CPU socket is empty ok(3): CPU is available and working properly disabled(4): CPU was…
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.5Columnsc2cpuModelNameread-onlymandatoryCPU model name (e.g. Pentium Xeon)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.6Columnsc2cpuManufacturerread-onlymandatoryCPU manufacturer name (e.g. Intel)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.7Columnsc2cpuStepread-onlymandatoryCPU step / revision
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.8Columnsc2cpuCurrentSpeedread-onlymandatoryCPU speed (frequency in MHz, -1 if unknown)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.9Columnsc2cpuNumberLogicalsread-onlymandatoryNumber of (physically available) logical CPUs within one physical CPU (for hyper-threading and multi-core CPUs). This is the sum of all cores and all logical C…
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.10Columnsc2cpuCacheL1Sizeread-onlymandatorySize of first level cache (in kBytes, 0 if unknown or not available)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.11Columnsc2cpuCacheL2Sizeread-onlymandatorySize of second level cache (in kBytes, 0 if unknown or not available)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.12Columnsc2cpuCacheL3Sizeread-onlymandatorySize of third level cache (in kBytes, 0 if unknown or not available)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.13Columnsc2cpuNumberCoresread-onlymandatoryNumber of (physically available) cores within one physical CPU (for multi-core CPUs, platform dependent), 0 if unknown or not available
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.14Columnsc2cpuFamilyread-onlymandatoryCPU family code. This enumerated value is specified by the DMTF SMBIOS specification (processor information, type 4).
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.15Columnsc2cpuEnabledCoresread-onlymandatoryNumber of effectively enabled cores within one physical CPU (for multi-core CPUs; 0 if unknown)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.16Columnsc2cpuMultithreadingEnabledread-onlymandatoryMultithreading of CPU enabled
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.17Columnsc2cpuConfigurationStatusread-onlymandatoryCPU configuration status: unknown(1): CPU status could not be evaluated normal(2): Regular CPU configuration disabledManually(3): CPU was manually disabled (in…
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.18Columnsc2cpuMCDRAMSizeread-onlymandatorySize of the onboard MCDRAM (GByte; 0 if no MCDRAM is available)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.19Columnsc2cpuMCDRAMSpeedread-onlymandatorySpeed of the onboard MCDRAM (MT/s; 0 if no MCDRAM is available)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.20Columnsc2cpuMCDRAMModeread-onlymandatoryOperation mode of the onboard MCDRAM: undefined(1): Mode is not defined (no MCDRAM available) flat(2): MCDRAM is used as standalone memory exclusively or in ad…
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.21Columnsc2cpuMCDRAMCacheSizeread-onlymandatoryPortion of the onboard MCDRAM used as a cache in hybrid mode (in percent; 0 if no MCDRAM is available or other mode than hybrid)
1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.22Columnsc2cpuMCDRAMMemoryModelread-onlymandatoryMemory model of the onboard MCDRAM: undefined(1): Model is not defined (no MCDRAM available) all2all(2): All2All subNumaCluster2(3): Sub NUMA Cluster - 2 subNu…
1.3.6.1.4.1.231.2.10.2.2.10.6.5Tablesc2MemoryModuleTablenot-accessiblemandatoryMain memory module table
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1Rowsc2MemoryModulesnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.1Columnsc2memUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.2Columnsc2memModuleNrread-onlymandatoryMemory module (socket) number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.3Columnsc2memModuleDesignationread-onlymandatoryMemory module designation (e.g. DIMM-2)
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.4Columnsc2memModuleStatusread-onlymandatoryMemory module status: unknown(1): Module status could not be evaluated not-present(2): Module socket is empty ok(3): Module is available and working properly d…
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.5Columnsc2memModuleBankread-onlymandatoryMemory module bank number (-1 if unknown) Due to the fact that modern mainboards do no longer have fixed banks, this value is OBSOLETE!
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.6Columnsc2memModuleCapacityread-onlymandatoryMemory module size (capacity in MBytes; -1 if unknown)
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.7Columnsc2memModuleStartAddressread-onlymandatoryMemory module start address (in MBytes; -1 if unknown) Due to the fact that modern mainboards do no longer show start addresses, this value is OBSOLETE!
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.8Columnsc2memModuleFormread-onlymandatoryMemory module form (SIMM, DIMM, ...)
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.9Columnsc2memModuleTyperead-onlymandatoryMemory module type (SDRAM, DDRAM, DDR2, DDR3, ...)
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.10Columnsc2memModuleCorrErrorsread-onlymandatoryNumber of memory module correctable errors (-1 if unknown)
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.11Columnsc2memModuleUncorrErrorsread-onlymandatoryNumber of memory module uncorrectable errors (-1 if unknown)
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.12Columnsc2memModuleApprovedread-onlymandatoryMemory module approved for this machine
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.13Columnsc2memModuleConfigurationread-onlymandatoryMemory module configuration: unknown(1): Module configuration could not be evaluated normal(2): Module is in normal non-redundant configuration or slot is empt…
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.14Columnsc2memModuleFrequencyread-onlymandatoryMemory module actual front side bus frequency (in MHz; -1 if unknown). This value is based on the BIOS settings
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.15Columnsc2memModuleMaxFrequencyread-onlymandatoryMemory module maximum front side bus frequency (in MHz; -1 if unknown). This value is based on memory module SPD data
1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.16Columnsc2memModuleVoltInterfaceread-onlymandatoryMemory module interface voltage interface description
1.3.6.1.4.1.231.2.10.2.2.10.6.6Scalarsc2cpuMultithreadEnableread-onlymandatoryMultithreading of CPU enabled This object is OBSOLETE for future implementations; use object 'sc2cpuMultithreadingEnabled' from 'sc2CPUTable' instead!
1.3.6.1.4.1.231.2.10.2.2.10.6.7Tablesc2ComponentPowerConsumptionTablenot-accessiblemandatoryTable of component power consumption data
1.3.6.1.4.1.231.2.10.2.2.10.6.7.1Rowsc2ComponentPowerConsumptionnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.1Columnsc2cpcUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.2Columnsc2cpcComponentClassread-onlymandatoryComponent class enumeration (based on IPMI v1.0 entity ID)
1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.3Columnsc2cpcComponentIndexread-onlymandatoryComponent index within class (1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.4Columnsc2cpcDesignationread-onlymandatoryComponent designation
1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.5Columnsc2cpcCurrentValueread-onlymandatoryCurrent component power consumption in Watts
1.3.6.1.4.1.231.2.10.2.2.10.6.8Tablesc2TrustedPlatformModuleTablenot-accessiblemandatoryTrusted Platform Module (TPM) status information (see corresponding TPM specification for detailed description of these states)
1.3.6.1.4.1.231.2.10.2.2.10.6.8.1Rowsc2TrustedPlatformModulenot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.1Columnsc2tpmUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.2Columnsc2tpmHardwareAvailableread-onlymandatoryTPM hardware is available ('unknown' if hardware availability cannot be detected; no interface found)
1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.3Columnsc2tpmBiosEnabledread-onlymandatoryTPM hardware is enabled by BIOS ('unknown' if hardware is not available; a reboot is required to change this value)
1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.4Columnsc2tpmEnabledread-onlymandatoryTPM is enabled (by software; cannot take ownership if disabled; 'unknown' if hardware is not available or disabled)
1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.5Columnsc2tpmActivatedread-onlymandatoryTPM is activated (by software; 'unknown' if hardware is not available or disabled)
1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.6Columnsc2tpmOwnershipread-onlymandatoryTPM ownership is established (valid endorsement key is existing; 'unknown' if hardware is not available or disabled)
1.3.6.1.4.1.231.2.10.2.2.10.6.9Tablesc2PersistentMemoryModuleTablenot-accessiblemandatoryAdditional information about persistent (non-volatile) memory modules to extend the sc2MemoryModuleTable. This table uses the index numbers of the previous sc2…
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1Rowsc2PersistentMemoryModulesnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.1Columnsc2nvmemMemoryModeEnabledread-onlymandatoryVolatime memory mode is enabled
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.2Columnsc2nvmemPersistentModeEnabledread-onlymandatoryPersistent memory mode is enabled
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.3Columnsc2nvmemPackageSparingCapableread-onlymandatoryModule is capable of providing spare memory
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.4Columnsc2nvmemEncryptionEnabledread-onlymandatoryMemory encryption is enabled
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.5Columnsc2nvmemFirmwareRevisionread-onlymandatoryFirmware revision
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.6Columnsc2nvmemTotalSizeread-onlymandatoryTotal size of memory module (in GBytes; including reserved spare space)
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.7Columnsc2nvmemRawCapacityread-onlymandatoryMaximum capacity that can be allocated for use in any of the supported modes (in GBytes; excluding reserved space)
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.8Columnsc2nvmemVolatileCapacityread-onlymandatoryCapacity of volatile memory (in GBytes)
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.9Columnsc2nvmemPersistentCapacityread-onlymandatoryCapacity of persistent memory (in GBytes)
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.10Columnsc2nvmemVolatilePercentread-onlymandatoryCapacity of volatile memory (in percent of total size)
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.11Columnsc2nvmemPersistentPercentread-onlymandatoryCapacity of persistent memory (in percent of total size)
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.12Columnsc2nvmemVolatileStartread-onlymandatoryStart address of the volatile memory region
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.13Columnsc2nvmemPersistentStartread-onlymandatoryStart address of the persistent memory region
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.14Columnsc2nvmemHealthStatusNonCriticalread-onlymandatoryNon-critical (warning) status
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.15Columnsc2nvmemHealthStatusCriticalread-onlymandatoryCritical status
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.16Columnsc2nvmemHealthStatusFatalread-onlymandatoryFatal error status (data loss has occurred or is imminent)
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.17Columnsc2nvmemPowerOnTimeread-onlymandatoryLifetime the DIMM has been powered on (in seconds)
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.18Columnsc2nvmemUpTimeread-onlymandatoryCurrent uptime of the DIMM for the current power cycle (in seconds)
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.19Columnsc2nvmemLiftetimeRemainingread-onlymandatoryRemaining predicted lifetime (in seconds; -1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.20Columnsc2nvmemAveragePowerBudgetread-onlymandatoryAverage Power Budget in mW
1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.21Columnsc2nvmemPeakPowerBudgetread-onlymandatoryPeak Power Budget in mW
1.3.6.1.4.1.231.2.10.2.2.10.7Nodesc2Recovery
1.3.6.1.4.1.231.2.10.2.2.10.7.1Tablesc2MessageLogTablenot-accessiblemandatoryError and event message handling
1.3.6.1.4.1.231.2.10.2.2.10.7.1.1Rowsc2MessageLogsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.1Columnsc2msgUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.2Columnsc2msgLogEntryNrread-onlymandatoryMessage log entry number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.3Columnsc2msgLogEntryDataread-onlymandatoryMessage log entry data (binary; one message per table entry)
1.3.6.1.4.1.231.2.10.2.2.10.7.2Tablesc2WatchdogTablenot-accessiblemandatoryWatchdogs
1.3.6.1.4.1.231.2.10.2.2.10.7.2.1Rowsc2Watchdogsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.1Columnsc2wdUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.2Columnsc2WatchdogTyperead-onlymandatoryWatchdog type
1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.3Columnsc2WatchdogStatusread-onlymandatoryWatchdog status
1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.4Columnsc2WatchdogTimeread-onlymandatoryWatchdog timeout period in seconds (-1 = unknown)
1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.5Columnsc2WatchdogActionread-onlymandatoryWatchdog timeout action; the value unknown(1) can't be written. Not all watchdog type allow setting all of the values (-> BADVALUE).
1.3.6.1.4.1.231.2.10.2.2.10.7.3Tablesc2RecoverySettingTablenot-accessiblemandatoryASR&R (Automatic server recovery and restart) settings
1.3.6.1.4.1.231.2.10.2.2.10.7.3.1Rowsc2RecoverySettingsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.1Columnsc2asrUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.2Columnsc2asrNrRebootRetriesread-onlymandatoryCurrent number of retries to reboot/restart the server when a failure shutdown (and power-off) had occured. After this number of retries the action defined in …
1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.3Columnsc2asrDefaultRebootRetriesread-onlymandatoryDefault number of retries for server failure reboot. The above object 'sc2asrNrRebootRetries' will be set to this value after the server is working properly fo…
1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.4Columnsc2asrNextBootSourceread-onlymandatorySource medium to boot from (next time): operating-system: boot from floppy or hard disk diag-system: boot from alternate diagnostic system (only for SCSI syste…
1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.5Columnsc2asrRebootFailActionread-onlymandatorySpecifies the action after a specified number of failed reboot retries (the object 'sc2asrNrRebootRetries' has reached zero). The value no-diag-system(4) means…
1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.6Columnsc2asrRestartDelayread-onlymandatoryDelay (in minutes) after that the system should be automatically switched on again (by real-time clock) after an error power-off. Setting this value to zero me…
1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.7Columnsc2asrPostErrorHaltread-onlymandatoryDescribes what to do when a POST error has occured (halt on any error, no halt on any error...).
1.3.6.1.4.1.231.2.10.2.2.10.7.4Tablesc2MessageTextLogTablenot-accessiblemandatoryError and event message handling, reported as text strings
1.3.6.1.4.1.231.2.10.2.2.10.7.4.1Rowsc2MessageTextLogsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.1Columnsc2msgTextLogUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.2Columnsc2msgTextLogLanguageread-onlymandatoryMessage log entry language (index, Windows language code) e.g. 1031, 1033 for German, English (default; always available)
1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.3Columnsc2msgTextLogSeqNrread-onlymandatoryMessage log entry sequence number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.4Columnsc2msgTextLogTimestampread-onlymandatoryMessage log entry time stamp (time_t = seconds since 1/1/1970, 0:00 AM as GMT)
1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.5Columnsc2msgTextLogMessageread-onlymandatoryMessage log entry message string (multi-byte string; multi-language; not every language may be implemented)
1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.6Columnsc2msgTextLogErrorCoderead-onlymandatoryMessage log entry error code
1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.7Columnsc2msgTextLogSeverityread-onlymandatoryMessage log entry severity
1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.8Columnsc2msgTextLogCSSComponentread-onlymandatoryComponent which caused the log message may be replaced by the customer (CSS=Customer Self Service)
1.3.6.1.4.1.231.2.10.2.2.10.7.5Tablesc2MessageLogActionHintTablenot-accessiblemandatoryAction text strings for error and event messages
1.3.6.1.4.1.231.2.10.2.2.10.7.5.1Rowsc2MessageLogActionHintsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.1Columnsc2mlaLanguageread-onlymandatoryAction text language (index, Windows language code) e.g. 1031, 1033 for German, English
1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.2Columnsc2mlaErrorCoderead-onlymandatoryAction text error code (index)
1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.3Columnsc2mlaTyperead-onlymandatoryMessage log entry severity
1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.4Columnsc2mlaIndexread-onlymandatoryAction text entry string index (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.5Columnsc2mlaMessageread-onlymandatoryAction message string
1.3.6.1.4.1.231.2.10.2.2.10.8Nodesc2Status
1.3.6.1.4.1.231.2.10.2.2.10.8.1Scalarsc2AgentStatusread-onlymandatoryOverall status of all monitored components in this agent ok(1): all components are working properly; no warnings, no errors warning(2): at least one component …
1.3.6.1.4.1.231.2.10.2.2.10.8.2Tablesc2StatusComponentTablenot-accessiblemandatoryTable with status values of the components in this agent. The table summarizes all instances of one component to one status value.
1.3.6.1.4.1.231.2.10.2.2.10.8.2.1Rowsc2StatusComponentsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.1Columnsc2csUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.2Columnsc2csStatusOverallread-onlymandatoryOverall status (worst status of all components) in this unit
1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.3Columnsc2csStatusBootread-onlymandatoryBoot status (errors from power-on selftest and boot)
1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.4Columnsc2csStatusPowerSupplyread-onlymandatoryPower supply status
1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.5Columnsc2csStatusTemperatureread-onlymandatoryTemperature status
1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.6Columnsc2csStatusFansread-onlymandatoryFan status
1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.7Columnsc2csStatusVoltagesread-onlymandatoryVoltage status
1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.8Columnsc2csStatusCpuread-onlymandatoryCPU status
1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.9Columnsc2csStatusMemoryModuleread-onlymandatoryMemory module status
1.3.6.1.4.1.231.2.10.2.2.10.8.3Tablesc2ComponentStatusSensorTablenot-accessiblemandatoryThis table contains the component status sensor table of the BMC (baseboard management controller). Additionally it also holds the CSS (Customer Self Service) …
1.3.6.1.4.1.231.2.10.2.2.10.8.3.1Rowsc2ComponentStatusSensorsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.1Columnsc2cssUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.2Columnsc2cssSensorNumberread-onlymandatoryBMC component status sensor number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.3Columnsc2cssSensorDesignationread-onlymandatoryComponent status sensor designation string
1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.4Columnsc2cssSensorDeviceread-onlymandatoryName of device (entity) the component status sensor belongs to
1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.5Columnsc2cssSensorDeviceInstanceread-onlymandatoryInstance number of device (entity) the component status sensor belongs to
1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.6Columnsc2cssSensorPhysicalLedread-onlymandatoryIf set, component has a physical status LED showing the sensor status
1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.7Columnsc2cssSensorCssComponentread-onlymandatoryIf set, component may be replaced by the customer (CSS 'custormer-self-service' component)
1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.8Columnsc2cssSensorStatusread-onlymandatoryStatus returned by the component status sensor
1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.9Columnsc2cssComponentServicePartIdread-onlymandatorySpare part number of the replaceable component; used to create a link to the spare part list on the service's spare part catalogue. This usually is the compone…
1.3.6.1.4.1.231.2.10.2.2.10.8.4Scalarsc2cssTableSizeread-onlymandatoryNumber of entries in the component status sensor table
1.3.6.1.4.1.231.2.10.2.2.10.9Nodesc2Maintenance
1.3.6.1.4.1.231.2.10.2.2.10.9.1Tablesc2MaintenanceObjectTablenot-accessiblemandatoryTable containing some other maintenance objects
1.3.6.1.4.1.231.2.10.2.2.10.9.1.1Rowsc2MaintenanceObjectsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.1Columnsc2mtUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.2Columnsc2ErrorCounterStartTimeread-onlymandatoryMemory module error counter start time (seconds since 1/1/1970, -1 if unknown). This is the time when the error counters were started or reset last time.
1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.3Columnsc2SendTestTrapread-writemandatorySend a test trap (test alarm) to the manager application(s) to test connection and trap configuration; trap cannot be disabled. Initiate test trap sending by w…
1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.4Columnsc2AddTrapDestinationread-writemandatoryAdd the specified IP address (of the management station) to the trap destination list of this server. That client will become an alarm receiver for traps of th…
1.3.6.1.4.1.231.2.10.2.2.10.9.2Tablesc2FirmwareVersionTablenot-accessiblemandatoryController firmware version table
1.3.6.1.4.1.231.2.10.2.2.10.9.2.1Rowsc2FirmwareVersionsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.1Columnsc2fwUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.2Columnsc2fwTyperead-onlymandatoryController/firmware type
1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.3Columnsc2fwModelNameread-onlymandatoryController/firmware model name (e.g. 'Copernicus'...)
1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.4Columnsc2fwVersionread-onlymandatoryController/firmware version string (e.g. '3.81.02')
1.3.6.1.4.1.231.2.10.2.2.10.10Nodesc2Deployment
1.3.6.1.4.1.231.2.10.2.2.10.10.1Tablesc2DeployInfoTablenot-accessiblemandatoryTable with data of deployment information. This table is OBSOLETE (no longer used for new implementations)!
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1Rowsc2DeployInfonot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.1Columnsc2dplInfoUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.2Columnsc2DeployInfoChassisIdread-onlymandatoryChassis serial number
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.3Columnsc2DeployInfoMacAddr1read-onlymandatoryMAC address 1
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.4Columnsc2DeployInfoMacAddr2read-onlymandatoryMAC address 2
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.5Columnsc2DeployInfoMacAddr3read-onlymandatoryMAC address 3
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.6Columnsc2DeployInfoMacAddr4read-onlymandatoryMAC address 4
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.7Columnsc2DeployInfoIpAddr1read-writemandatoryIP address 1
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.8Columnsc2DeployInfoIpAddr2read-writemandatoryIP address 2
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.9Columnsc2DeployInfoIpAddr3read-writemandatoryIP address 3
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.10Columnsc2DeployInfoIpAddr4read-writemandatoryIP address 4
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.11Columnsc2DeployInfoNetMask1read-writemandatoryIP subnet mask 1
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.12Columnsc2DeployInfoNetMask2read-writemandatoryIP subnet mask 2
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.13Columnsc2DeployInfoNetMask3read-writemandatoryIP subnet mask 3
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.14Columnsc2DeployInfoNetMask4read-writemandatoryIP subnet mask 4
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.15Columnsc2DeployInfoGateway1read-writemandatoryIP gateway 1
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.16Columnsc2DeployInfoGateway2read-writemandatoryIP gateway 2
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.17Columnsc2DeployInfoGateway3read-writemandatoryIP gateway 3
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.18Columnsc2DeployInfoGateway4read-writemandatoryIP gateway 4
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.19Columnsc2DeployInfoHostnameread-writemandatoryHost name
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.20Columnsc2DeployInfoMasterImageReferenceread-writemandatoryURL in UNC notification (but in ASCII) to remote image file (with the extensions of *.img, *.cfg, *.txt)
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.21Columnsc2DeployInfoStatusOfBladeread-writemandatoryStatus of this server: power-down(2): waiting for boot standby(3): power management mode system-boot-failure(4): system boot failure bios-setup(5): BIOS setup …
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.22Columnsc2DeployInfoLanStatusOfSlotread-writemandatoryDefines wether the IP-LAN definitions are valid or not.
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.23Columnsc2DeployInfoAutomaticRecoveryread-writemandatoryDefines if this server blade should be provided automatic recovery.
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.24Columnsc2DeployInfoStatusOfCloningread-writemandatoryStatus of current cloning process.
1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.25Columnsc2DeployInfoBootModeread-writemandatoryBoot mode of the server for remote deployment: normal(2): boot from standard disk subsystem pxeBiosSetup(3): boot from PXE according to BIOS setup settings (fo…
1.3.6.1.4.1.231.2.10.2.2.10.10.2Tablesc2OemDeployInfoTablenot-accessiblemandatoryTable with data of server OEM information. This table is OBSOLETE (no longer used for new implementations)!
1.3.6.1.4.1.231.2.10.2.2.10.10.2.1Rowsc2OemDeployInfonot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.1Columnsc2odplInfoUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.2Columnsc2odplParamIdread-onlymandatoryOEM parameter ID (index, 1..10)
1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.3Columnsc2OemDeployInfoParamDataread-writemandatoryOEM parameter data
1.3.6.1.4.1.231.2.10.2.2.10.10.3Tablesc2DeployLanInterfaceTablenot-accessiblemandatoryTable with system LAN interfaces information: This table lists all real LAN interfaces in same physical order as the BIOS uses it for PXE boot. Only on-board i…
1.3.6.1.4.1.231.2.10.2.2.10.10.3.1Rowsc2DeployLanInterfacesnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.1Columnsc2dplLanUnitIdread-onlymandatoryUnit identifier (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.2Columnsc2dplLanInterfaceNrread-onlymandatoryLAN interface number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.3Columnsc2dplLanMacAddressread-onlymandatoryLAN interface hardware (MAC) address
1.3.6.1.4.1.231.2.10.2.2.10.11Nodesc2DriverMonitoring
1.3.6.1.4.1.231.2.10.2.2.10.11.1Tablesc2DriverMonitorComponentTablenot-accessiblemandatoryTable of components monitored by the driver monitor. Foreign index sc2uUnitId is from sc2UnitTable.
1.3.6.1.4.1.231.2.10.2.2.10.11.1.1Rowsc2DriverMonitorComponentsnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.1Columnsc2drvmonCompClassread-onlymandatoryComponent class (index)
1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.2Columnsc2drvmonCompIndexread-onlymandatoryComponent index (index, 1..n). This is an index over all component classes, but unit specific.
1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.3Columnsc2drvmonCompNameread-onlymandatoryName or designation of the component
1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.4Columnsc2drvmonCompTyperead-onlymandatoryComponent (bus) type
1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.5Columnsc2drvmonCompDriverNameread-onlymandatoryName of the driver that created the event record
1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.6Columnsc2drvmonCompLocationDesignationread-onlymandatoryDevice location designation (if it is an adapter or other hardware component); e.g. 'PCI Slot #2' or 'IOB#1-FUNC#0'
1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.7Columnsc2drvmonCompLocationKeyread-onlymandatoryDevice location key, used for identifying the component in other tables (like PCI device table); e.g. 'TYPE_PCI&BUS_3&DEV_14&FUNC_0'
1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.8Columnsc2drvmonCompStatusread-onlymandatoryStatus of the component; caused by specific error events, reset by corresponding 'component OK' events or by manual acknowledge
1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.9Columnsc2drvmonCompErrorAcknowledgeread-writemandatoryAcknowledge an error condition (reset error or warning status) of the component by writing a non-zero value (reading this object just returns the value 0)
1.3.6.1.4.1.231.2.10.2.2.10.11.2Tablesc2DriverMonitorMessageTablenot-accessiblemandatoryTable of messages gathered by the driver monitor. The messages are based on the monitored operating system event log and are available in translated languages.…
1.3.6.1.4.1.231.2.10.2.2.10.11.2.1Rowsc2DriverMonitorMessagesnot-accessiblemandatory
1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.1Columnsc2drvmonMsgSeqNrread-onlymandatoryDriver message entry sequence number (index, 1..n)
1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.2Columnsc2drvmonMsgTimestampread-onlymandatoryDriver message entry time stamp (time_t = seconds since 1/1/1970, 0:00 AM as GMT)
1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.3Columnsc2drvmonMsgMessageread-onlymandatoryMessage entry string (multi-language; not every language may be implemented, then English message has to be requested)
1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.4Columnsc2drvmonMsgEventIdread-onlymandatoryMessage entry error code (this code is a driver monitor specific error code)
1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.5Columnsc2drvmonMsgSeverityread-onlymandatoryMessage entry severity (may be different from original event log severity)
1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.6Columnsc2drvmonMsgErrorCoderead-onlymandatoryMessage entry error code (must be used to get summary, causes and resolutions from sc2MessageLogActionHintTable table)
1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.7Columnsc2drvmonOrigLogMessageread-onlymandatoryOriginal operating system event log / syslog entry message (only available in the server's original language or in english, depending on the driver that create…
1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.8Columnsc2drvmonOrigLogSourceread-onlymandatoryOriginal log entry source name
1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.9Columnsc2drvmonOrigLogIdread-onlymandatoryOriginal log entry ID number (may not be available for some platforms/controllers, then ID = 0)
1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.10Columnsc2drvmonOrigLogSeverityread-onlymandatoryOriginal event log entry severity
1.3.6.1.4.1.231.2.10.2.2.10.11.3Scalarsc2drvmonTableUpdateCountread-onlymandatoryCounter defining the update revision of the driver monitoring tables. This counter is incremented with every change/update of the driver monitoring tables.
1.3.6.1.4.1.231.2.10.2.2.10.20Nodesc2Notifications
1.3.6.1.4.1.231.2.10.2.2.10.20.1Nodesc2NotificationsTrapInfo
1.3.6.1.4.1.231.2.10.2.2.10.20.1.1Scalarsc2TrapInfoServerNamenot-accessiblemandatoryName of the server the trap comes from
1.3.6.1.4.1.231.2.10.2.2.10.20.1.2Scalarsc2TrapInfoTimenot-accessiblemandatoryTime when the trap occured (in seconds since 01/01/1970 00:00h)
1.3.6.1.4.1.231.2.10.2.2.10.20.1.3Scalarsc2TrapInfoCabinetNrnot-accessiblemandatoryCabinet number generating the trap
1.3.6.1.4.1.231.2.10.2.2.10.20.1.4Scalarsc2TrapInfoObjectDesignationnot-accessiblemandatoryDesignation string for object that generated the trap (fan, temperature sensor...)
1.3.6.1.4.1.231.2.10.2.2.10.20.1.5Scalarsc2TrapInfoStringnot-accessiblemandatoryAdditional string to be displayed in the trap text
1.3.6.1.4.1.231.2.10.2.2.10.20.1.6Scalarsc2TrapInfoIntegernot-accessiblemandatoryAdditional number to be displayed in the trap text
1.3.6.1.4.1.231.2.10.2.2.10.20.1.7Scalarsc2TrapInfoInteger2not-accessiblemandatoryAdditional number to be displayed in the trap text
1.3.6.1.4.1.231.2.10.2.2.10.20.2000Nodesc2TrapTestTest trap to verify trap connection.
1.3.6.1.4.1.231.2.10.2.2.10.20.2001Nodesc2TrapCommunicationFailureThe communication with management controller failed!
1.3.6.1.4.1.231.2.10.2.2.10.20.2002Nodesc2TrapCommunicationEstablishedThe communication with the management controller was reestablished
1.3.6.1.4.1.231.2.10.2.2.10.20.2003Nodesc2TrapControllerSelftestWarningController selftest warning.
1.3.6.1.4.1.231.2.10.2.2.10.20.2004Nodesc2TrapControllerSelftestErrorController selftest error.
1.3.6.1.4.1.231.2.10.2.2.10.20.2005Nodesc2TrapBiosSelftestErrorA critical error happend while BIOS selftest. This error needs to be acknowledged to clear the error condition.
1.3.6.1.4.1.231.2.10.2.2.10.20.2006Nodesc2TrapSevereSystemErrorThe system was restarted after a severe problem. See server management message log (recovery log) for detailed information.
1.3.6.1.4.1.231.2.10.2.2.10.20.2010Nodesc2TrapFanAddedThe indicated hot-plug fan or liquid pump was inserted.
1.3.6.1.4.1.231.2.10.2.2.10.20.2011Nodesc2TrapFanRemovedThe indicated hot-plug fan or liquid pump was removed.
1.3.6.1.4.1.231.2.10.2.2.10.20.2012Nodesc2TrapFanOkThe indicated fan or liquid pump is working again.
1.3.6.1.4.1.231.2.10.2.2.10.20.2013Nodesc2TrapFanCriticalThe indicated fan or liquid pump became critical
1.3.6.1.4.1.231.2.10.2.2.10.20.2014Nodesc2TrapFanFailedThe indicated fan or liquid pump failed.
1.3.6.1.4.1.231.2.10.2.2.10.20.2015Nodesc2TrapRedundantFanFailedThe indicated redundant fan or liquid pump failed
1.3.6.1.4.1.231.2.10.2.2.10.20.2020Nodesc2TrapTempOkThe temperature of the indicated sensor has decreased to the normal level.
1.3.6.1.4.1.231.2.10.2.2.10.20.2021Nodesc2TrapTempWarningThe temperature of the indicated sensor has reached the warning level.
1.3.6.1.4.1.231.2.10.2.2.10.20.2022Nodesc2TrapTempCriticalThe temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled.
1.3.6.1.4.1.231.2.10.2.2.10.20.2023Nodesc2TrapTempSensorOkThe indicated broken temperature sensor is OK again.
1.3.6.1.4.1.231.2.10.2.2.10.20.2024Nodesc2TrapTempSensorBrokenThe indicated temperature sensor is broken.
1.3.6.1.4.1.231.2.10.2.2.10.20.2030Nodesc2TrapPowerSupplyAddedOne hot-replace power supply was added.
1.3.6.1.4.1.231.2.10.2.2.10.20.2031Nodesc2TrapPowerSupplyRemovedOne hot-replace power supply was removed
1.3.6.1.4.1.231.2.10.2.2.10.20.2032Nodesc2TrapPowerSupplyOkPower supply is working again.
1.3.6.1.4.1.231.2.10.2.2.10.20.2033Nodesc2TrapPowerSupplyCriticalPower supply status has become critical.
1.3.6.1.4.1.231.2.10.2.2.10.20.2034Nodesc2TrapPowerSupplyFailedOne hot-replace power supply failed.
1.3.6.1.4.1.231.2.10.2.2.10.20.2035Nodesc2TrapRedundantPowerSupplyFailedOne redundant hot-replace power supply failed
1.3.6.1.4.1.231.2.10.2.2.10.20.2036Nodesc2TrapPowerSupplyRedundancyLostPower supply redundancy no longer available.
1.3.6.1.4.1.231.2.10.2.2.10.20.2037Nodesc2TrapPowerSupplyCriticalTemperatureCritical temperature in power supply.
1.3.6.1.4.1.231.2.10.2.2.10.20.2038Nodesc2TrapPowerSupplyFanFailurePredictionFan failure prediction in power supply.
1.3.6.1.4.1.231.2.10.2.2.10.20.2039Nodesc2TrapPowerSupplyFanFailureFan failure in power supply.
1.3.6.1.4.1.231.2.10.2.2.10.20.2040Nodesc2TrapAcFailMains failed in the specified cabinet. This trap can only happen in storage extension cabinets without UPS or BBU. A server will not have time to send this tra…
1.3.6.1.4.1.231.2.10.2.2.10.20.2041Nodesc2TrapDcFailDC power failed in the specified cabinet. This is the result of the system's power-good sensor monitoring. The system may stop when this condition occurs.
1.3.6.1.4.1.231.2.10.2.2.10.20.2042Nodesc2TrapOnBatteryThe server is operating on battery power - by UPS or backup battery unit (BBU).
1.3.6.1.4.1.231.2.10.2.2.10.20.2043Nodesc2TrapOnMainsThe mains voltage returned after a power failure.
1.3.6.1.4.1.231.2.10.2.2.10.20.2050Nodesc2TrapVoltageOkPower supply voltage is within normal range again.
1.3.6.1.4.1.231.2.10.2.2.10.20.2051Nodesc2TrapVoltageTooLowPower supply voltage is too low.
1.3.6.1.4.1.231.2.10.2.2.10.20.2052Nodesc2TrapVoltageTooHighPower supply voltage is too high.
1.3.6.1.4.1.231.2.10.2.2.10.20.2053Nodesc2TrapVoltageFailedPower supply voltage is out of range.
1.3.6.1.4.1.231.2.10.2.2.10.20.2054Nodesc2TrapBatteryVoltagePrefailBattery is predicted to fail
1.3.6.1.4.1.231.2.10.2.2.10.20.2060Nodesc2TrapCorrectableMemErrorAddrA correctable memory error at specified address was detected.
1.3.6.1.4.1.231.2.10.2.2.10.20.2061Nodesc2TrapUncorrectableMemErrorAddrAn uncorrectable memory error at specified address was detected.
1.3.6.1.4.1.231.2.10.2.2.10.20.2062Nodesc2TrapCorrectableMemErrorBankA correctable memory error at specified bank was detected.
1.3.6.1.4.1.231.2.10.2.2.10.20.2063Nodesc2TrapUncorrectableMemErrorBankAn uncorrectable memory error at specified bank was detected.
1.3.6.1.4.1.231.2.10.2.2.10.20.2064Nodesc2TrapCorrectableMemErrorModuleA correctable memory error at specified module was detected.
1.3.6.1.4.1.231.2.10.2.2.10.20.2065Nodesc2TrapUncorrectableMemErrorModuleAn uncorrectable memory error at specified module was detected.
1.3.6.1.4.1.231.2.10.2.2.10.20.2066Nodesc2TrapCorrectableMemErrorA correctable memory error at unknown location was detected.
1.3.6.1.4.1.231.2.10.2.2.10.20.2067Nodesc2TrapUncorrectableMemErrorAn uncorrectable memory error at unknown location was detected.
1.3.6.1.4.1.231.2.10.2.2.10.20.2068Nodesc2TrapMemErrorModulePrefailA memory module is predicted to fail (prefailure).
1.3.6.1.4.1.231.2.10.2.2.10.20.2069Nodesc2TrapMemErrorModuleFailingA memory module is failing.
1.3.6.1.4.1.231.2.10.2.2.10.20.2070Nodesc2TrapMemErrorModuleReplacedA memory module had failed and was replaced by a hot-spare module.
1.3.6.1.4.1.231.2.10.2.2.10.20.2071Nodesc2TrapMemErrorLoggingDisabledToo many correctable memory errors; logging disabled.
1.3.6.1.4.1.231.2.10.2.2.10.20.2072Nodesc2TrapMemErrorLoggingEnabledMemory errors logging enabled again.
1.3.6.1.4.1.231.2.10.2.2.10.20.2073Nodesc2TrapMemErrorAnyModuleReplacedA memory module had failed and was replaced by a hot-spare module.
1.3.6.1.4.1.231.2.10.2.2.10.20.2074Nodesc2TrapMemErrorRedundancyLostA memory error caused loss of memory redundancy
1.3.6.1.4.1.231.2.10.2.2.10.20.2075Nodesc2TrapMemNVDIMMLifetimeAn NVDIMM memory module has reached a certain level of lifetime
1.3.6.1.4.1.231.2.10.2.2.10.20.2080Nodesc2TrapCpuSpeedChangedThis trap will be sent if the CPU clock frequency was changed because of a temperature problem.
1.3.6.1.4.1.231.2.10.2.2.10.20.2081Nodesc2TrapCpuPrefailA CPU is predicted to fail (prefailure).
1.3.6.1.4.1.231.2.10.2.2.10.20.2082Nodesc2TrapCpuIerrA CPU internal error (IERR) occurred
1.3.6.1.4.1.231.2.10.2.2.10.20.2083Nodesc2TrapCpuDisabledA CPU is disabled by BIOS
1.3.6.1.4.1.231.2.10.2.2.10.20.2090Nodesc2TrapCabinetSwitchedOffThis trap will be sent when a cabinet is switched off. For obvious reasons it cannot be sent when the main cabinet is switched off.
1.3.6.1.4.1.231.2.10.2.2.10.20.2091Nodesc2TrapCabinetSwitchedOnThis trap will be sent when a cabinet is switched on.
1.3.6.1.4.1.231.2.10.2.2.10.20.2092Nodesc2TrapPowerOffTimeReachedThis trap is sent when the server is going to be switched off by schedule in some minutes.
1.3.6.1.4.1.231.2.10.2.2.10.20.2093Nodesc2TrapServerShutdownThis trap will be sent when a server is being shut down.
1.3.6.1.4.1.231.2.10.2.2.10.20.2094Nodesc2TrapShutdownCancelledThis trap will be sent if a pending server shutdown was cancelled by the user.
1.3.6.1.4.1.231.2.10.2.2.10.20.2095Nodesc2TrapBootRetryCountZeroThis trap will be sent when a boot retry counter gets zero on power up.
1.3.6.1.4.1.231.2.10.2.2.10.20.2096Nodesc2TrapServerBootThis trap will be sent when the server was booted
1.3.6.1.4.1.231.2.10.2.2.10.20.2097Nodesc2TrapServerStandbyThis trap will be sent when the server entered standby mode
1.3.6.1.4.1.231.2.10.2.2.10.20.2098Nodesc2TrapServerSuspendThis trap will be sent when the server entered suspend mode
1.3.6.1.4.1.231.2.10.2.2.10.20.2099Nodesc2TrapServerResumedThis trap will be sent when the server resumed from standby or suspend mode
1.3.6.1.4.1.231.2.10.2.2.10.20.2100Nodesc2TrapMessageLogFullThe System Event Log (message log) is full. No more messages can be logged. This trap will not occur on wrap-around log types
1.3.6.1.4.1.231.2.10.2.2.10.20.2101Nodesc2TrapMessageLogWarningThe warning threshold for the number of System Event Log entries has been exceeded.
1.3.6.1.4.1.231.2.10.2.2.10.20.2102Nodesc2TrapBootMessageLogEntryAn error message was written into the systemboard's message log. This could have happened when an error occured before the server management agents were runnin…
1.3.6.1.4.1.231.2.10.2.2.10.20.2110Nodesc2TrapIntrusionAssertionThe front door or housing was opened
1.3.6.1.4.1.231.2.10.2.2.10.20.2111Nodesc2TrapIntrusionDeassertionThe front door or housing was closed
1.3.6.1.4.1.231.2.10.2.2.10.20.2112Nodesc2TrapIntrusionChangedThe front door or housing was opened or closed
1.3.6.1.4.1.231.2.10.2.2.10.20.2113Nodesc2TrapPciBusErrorPCI bus system/parity error
1.3.6.1.4.1.231.2.10.2.2.10.20.2114Nodesc2TrapPowerOnTimeReachedThis trap is sent when the server is going to be switched on by schedule in some minutes. It will be sent by the Remote Management Controller.
1.3.6.1.4.1.231.2.10.2.2.10.20.2120Nodesc2TrapCssWarningCustomer self service component changed to warning status
1.3.6.1.4.1.231.2.10.2.2.10.20.2121Nodesc2TrapCssFailCustomer self service component changed to fail status
1.3.6.1.4.1.231.2.10.2.2.10.20.2122Nodesc2TrapCssWarningServerCustomer self service component changed to warning status
1.3.6.1.4.1.231.2.10.2.2.10.20.2123Nodesc2TrapCssFailServerCustomer self service component changed to fail status
1.3.6.1.4.1.231.2.10.2.2.10.20.2130Nodesc2TrapPowerLimitOkPower consumption limit changed to Ok status
1.3.6.1.4.1.231.2.10.2.2.10.20.2131Nodesc2TrapPowerLimitWarningPower consumption limit changed to warning status
1.3.6.1.4.1.231.2.10.2.2.10.20.2132Nodesc2TrapPowerLimitCriticalPower consumption limit changed to critical status
1.3.6.1.4.1.231.2.10.2.2.10.20.2133Nodesc2TrapPowerLimitDisabledPower consumption limiting disabled
1.3.6.1.4.1.231.2.10.2.2.10.20.2140Nodesc2TrapViomInitiateCommunicationVIOM communication initiation request - VIOM manager action required. This trap is intended to signal the Virtual IO Manager that the iRMC wants to confirm the…
1.3.6.1.4.1.231.2.10.2.2.10.20.2141Nodesc2TrapViomStatusChangedVIOM status has changed - VIOM manager information. If the user or a server management component deactivates VIOM, the iRMC will send a VIOM status trap. This …
1.3.6.1.4.1.231.2.10.2.2.10.20.2150Nodesc2TrapDrvMonEventMessageDriver Monitoring detected an informational event.
1.3.6.1.4.1.231.2.10.2.2.10.20.2151Nodesc2TrapDrvMonEventWarningDriver Monitoring detected a warning event.
1.3.6.1.4.1.231.2.10.2.2.10.20.2152Nodesc2TrapDrvMonEventErrorDriver Monitoring detected an error event.
Type Definitions
NameSyntaxStatusDescription
CompStatusINTEGER { ok(1), warning(2), error(3), unknown(5), notPresent(6), notManageable(7) }
LogSeverityINTEGER { informational(1), minor(2), major(3), critical(4) }
OsLogSeverityINTEGER { ok(1), warning(2), error(3) }
PhysAddressOCTET STRING
TrueFalseINTEGER { false(1), true(2) }
TrueFalseUnknownINTEGER { unknown(1), false(2), true(3) }
UnitClassINTEGER { unknown(1), standardServer(2), storageExtension(3), bladeServerChassis(4), bladeServer(5), clusterNode(6), multiNodeChassis(7), multiNodeServer(8), virtualServer(9), virtualPartition(10), systemboardInPartition(11), virtualServerVmware(20), virtualServerHyperV(21), virtualServerXen(22), virtualServerPan(23) }