FSC-SERVERCONTROL2-MIB
577 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1 | Nodeenterprises | |||
| 1.3.6.1.4.1.231 | Nodesni | |||
| 1.3.6.1.4.1.231.2 | NodesniProductMibs | |||
| 1.3.6.1.4.1.231.2.10 | NodesniExtensions | |||
| 1.3.6.1.4.1.231.2.10.2 | NodesniServerMgmt | |||
| 1.3.6.1.4.1.231.2.10.2.1 | NodesniInventory | |||
| 1.3.6.1.4.1.231.2.10.2.2 | NodesniCommon | |||
| 1.3.6.1.4.1.231.2.10.2.2.10 | NodefscServerControl2 | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.1 | Nodesc2AgentInfo | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.1.1 | Scalarsc2AgentId | read-only | mandatory | Agent identification string |
| 1.3.6.1.4.1.231.2.10.2.2.10.1.2 | Scalarsc2AgentCompany | read-only | mandatory | Agent's company name (e.g. Fujitsu Technology Solutions) |
| 1.3.6.1.4.1.231.2.10.2.2.10.1.3 | Scalarsc2AgentVersion | read-only | mandatory | Agent's version string (e.g. 1.05) |
| 1.3.6.1.4.1.231.2.10.2.2.10.1.4 | Scalarsc2AgentBuild | read-only | mandatory | Compilation time and date of agent program |
| 1.3.6.1.4.1.231.2.10.2.2.10.1.5 | Scalarsc2AgentWriteAllowed | read-only | mandatory | Defines whether writable objects can be written (except shutdown/power-off operations) |
| 1.3.6.1.4.1.231.2.10.2.2.10.1.6 | Scalarsc2AgentShutdownAllowed | read-only | mandatory | Defines whether shutdown/power-off objects can be written |
| 1.3.6.1.4.1.231.2.10.2.2.10.2 | Nodesc2UnitInformation | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.2.1 | Scalarsc2LocalServerUnitId | read-only | mandatory | Unit identifier number of the local server (usually is ID 1). This ID can be used as index into the sc2Units table. |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.2 | Scalarsc2NumberUnits | read-only | mandatory | Number of available units (size of sc2Units table). |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3 | Tablesc2UnitTable | not-accessible | mandatory | Description of all units in this MIB |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1 | Rowsc2Units | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.1 | Columnsc2uUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.2 | Columnsc2UnitClass | read-only | mandatory | Unit classification (type) |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.3 | Columnsc2UnitCabinetNr | read-only | mandatory | Unit cabinet number (used for addressing storage extension cabinets or server blades). The ID of the local server is usually 0. |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.4 | Columnsc2UnitDesignation | read-only | mandatory | Unit designation / housing type (e.g. 'H200R') |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.5 | Columnsc2UnitModelName | read-only | mandatory | Unit model name (e.g. 'PRIMERGY RX100') |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.6 | Columnsc2UnitManufacturer | read-only | mandatory | Unit manufacturer name (e.g. 'Fujitsu Technology Solutions') |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.7 | Columnsc2UnitSerialNumber | read-only | mandatory | Unit serial number (e.g. 'YBCL123456') |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.8 | Columnsc2UnitLocation | read-only | mandatory | Unit location string (e.g. 'ServerCenter Room 17, Rack 9') |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.9 | Columnsc2UnitContact | read-only | mandatory | Unit contact name (e.g. 'Mr. Bond') |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.10 | Columnsc2UnitAdminURL | read-only | mandatory | URL of administration HTML interface (e.g. 'http://MyServer/admin') |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.11 | Columnsc2FrontDoorStatus | read-only | mandatory | Status describing whether the front door is open or closed |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.12 | Columnsc2HousingOpenStatus | read-only | mandatory | Status describing whether the housing is open or closed |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.13 | Columnsc2MsgLogLanguages | read-only | mandatory | Supported languages of text message log (comma-seperated list of decimal language codes, see sc2MessageTextLogTable). e.g. '1031,1033' means German and English… |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.14 | Columnsc2UnitWorldWideName | read-only | mandatory | Unit World Wide Name. A 64-bit sized address for storage devices (e.g. '6661E2B0A00B88FB') |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.15 | Columnsc2RemcsId | read-only | mandatory | REMCS system identification string (binary data): Format of Fujitsu REMCS ID (40byte) Format = TTMMMMMMMMMMMMmmmmmmmmmmmmCCnnnnnnnnnnnn TT : 2byte : Type ID fo… |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.16 | Columnsc2AssetTag | read-only | mandatory | Customer specific asset tag (40 bytes) |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.17 | Columnsc2MsgLogAvailable | read-only | mandatory | Replies whether a message log is available on this unit |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.18 | Columnsc2ManagementIpAddress | read-only | mandatory | IPv4 address of the server for management purpose with PRIMEQUEST systems only. This is the interface address for managing a server by external management clie… |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.19 | Columnsc2HasUefiFirmware | read-only | mandatory | Replies whether the system is equipped with UEFI firmware |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.3.1.20 | Columnsc2ManagementIpAddressV6 | read-only | mandatory | IPv6 address of the server for management purpose with PRIMEQUEST systems only. This is the interface address for managing a server by external management clie… |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.4 | Scalarsc2UnitTableUpdateCount | read-only | mandatory | Counter defining the update revision of the unit table. This counter is incremented with every table contents change/update. |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.5 | Tablesc2UnitParentTable | not-accessible | mandatory | Parent-child relationship of all units: list the parent of all available units. Only units that have a parent are listed in this table. |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1 | Rowsc2UnitParents | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.1 | Columnsc2pUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.2 | Columnsc2ParentUnit | read-only | mandatory | Unit identifier of this unit's parent |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.5.1.3 | Columnsc2ParentUnitClass | read-only | mandatory | Parent unit classification (type). This is the same value as in sc2Units table, but can be used for easy class detection. |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.6 | Tablesc2UnitChildTable | not-accessible | mandatory | Parent-child relationship of all units: list all children of all available units. Only units that have children are listed in this table. |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1 | Rowsc2UnitChilds | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.1 | Columnsc2cUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.2 | Columnsc2cChildNr | read-only | mandatory | Child number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.3 | Columnsc2ChildUnit | read-only | mandatory | Child unit |
| 1.3.6.1.4.1.231.2.10.2.2.10.2.6.1.4 | Columnsc2ChildUnitClass | read-only | mandatory | Unit classification (type). This is the same value as in sc2Units table, but can be used for easy class detection. |
| 1.3.6.1.4.1.231.2.10.2.2.10.3 | Nodesc2Management | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1 | Tablesc2ManagementNodeTable | not-accessible | mandatory | SNMP management node addresses (how to address the units) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1 | Rowsc2ManagementNodes | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.1 | Columnsc2mnUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.2 | Columnsc2mnNodeNr | read-only | mandatory | Management node address number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.3 | Columnsc2UnitNodeIfType | read-only | mandatory | Management node interface type |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.4 | Columnsc2UnitNodeAddress | read-only | mandatory | Management node address (e.g. 192.168.0.100) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.5 | Columnsc2UnitNodeIpNetmask | read-only | mandatory | Management node address (e.g. 255.255.255.128) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.6 | Columnsc2UnitNodeGateway | read-only | mandatory | Management node address (e.g. 192.168.0.126) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.7 | Columnsc2UnitNodeName | read-only | mandatory | Management node name (DNS name, e.g. apollo.ts.fujitsu.com) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.8 | Columnsc2UnitNodeClass | read-only | mandatory | Management node class: primary: local operating system interface secondary: local management controller LAN interface management-blade: management blade interf… |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.9 | Columnsc2UnitNodeMacAddress | read-only | mandatory | Management node hardware (MAC) address |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.10 | Columnsc2UnitNodeUseDHCP | read-only | mandatory | Management node uses DHCP to obtain its address |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.11 | Columnsc2UnitNodeControllerType | read-only | mandatory | The type of the remote management controller (for identification), like 'RSB', 'RSB S2', 'RSB S2 LP'... These names will not be changed if defined once. |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.12 | Columnsc2UnitNodeControllerModel | read-only | mandatory | The model name of the remote management controller (for displaying), like 'Remote Service Board', 'RemoteView Service Board S2'... This name should not be used… |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.13 | Columnsc2UnitNodeControllerFWVersion | read-only | mandatory | The FW version of the remote management controller |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.14 | Columnsc2UnitNodeControllerStorage | read-only | mandatory | Status of the controller specific external storage used for the system management. |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.15 | Columnsc2UnitNodeSNMPEnabled | read-only | mandatory | SNMP interface is enabled at management node |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.16 | Columnsc2UnitNodeCIMEnabled | read-only | mandatory | CIM protocol is enabled at management node |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.1.1.17 | Columnsc2UnitNodeRemoteIPMIEnabled | read-only | mandatory | Remote IPMI is enabled at management node |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.2 | Scalarsc2NodeTableUpdateCount | read-only | mandatory | Counter defining the update revision of the management node table. This counter is incremented with every table contents change/update. |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.3 | Scalarsc2ManagementChannelType | read-only | mandatory | The type of the management channel currently used (this MIB instance). |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.4 | Tablesc2ManagementProcessorTable | not-accessible | mandatory | System management service processors |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1 | Rowsc2ManagementProcessors | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.1 | Columnsc2spUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.2 | Columnsc2spProcessorNr | read-only | mandatory | Service processor number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.3 | Columnsc2spModelName | read-only | mandatory | Service processor model name |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.4 | Columnsc2spFirmwareVersion | read-only | mandatory | Service processor firmware version / revision |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.5 | Columnsc2spBatteryStatus | read-only | mandatory | Service processor backup battery status |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.6 | Columnsc2spBatteryDischargeTime | read-only | mandatory | Maximum time (in seconds) this backup battery can discharged, after that a shutdown will be performed (-1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.7 | Columnsc2spTimeOnBattery | read-only | mandatory | Time (in seconds) the service processor is running on battery since power fail (will be cleared on power recovery) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.8 | Columnsc2spDoBatteryChargeCycle | read-write | mandatory | Perform a discharge/charge cycle on the backup battery by writing a non-zero value. Reading this object just returns the value 0. |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.4.1.9 | Columnsc2spBatteryChargeLevel | read-only | mandatory | Reads the current charge level of the rechargeable battery (in percent of the maximum capacity). |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.5 | Tablesc2ManagedUpsNodeTable | not-accessible | mandatory | UPS nodes managed by the units |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1 | Rowsc2ManagedUpsNodes | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.1 | Columnsc2upsUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.2 | Columnsc2upsNr | read-only | mandatory | UPS number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.3 | Columnsc2upsVendorName | read-only | mandatory | UPS vendor name |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.4 | Columnsc2upsModelName | read-only | mandatory | UPS model name |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.5 | Columnsc2upsMgmtAddress | read-only | mandatory | UPS management interface target address (represented as string; may contain an IP V4 address, IP V6 address or a URL) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.6 | Columnsc2upsMibRoot | read-only | mandatory | UPS MIB root OID; specifies the root OID of the MIB to be used to query UPS via SNMP (empty string if no SNMP agent available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.5.1.7 | Columnsc2upsSnmpCommunity | read-only | mandatory | UPS SNMP community name (empty string if no SNMP agent available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.3.6 | Scalarsc2UpsNodeTableUpdateCount | read-only | mandatory | Counter defining the update revision of the UPS node table. This counter is incremented with every table contents change/update. |
| 1.3.6.1.4.1.231.2.10.2.2.10.4 | Nodesc2ServerInformation | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1 | Tablesc2ServerTable | not-accessible | mandatory | Table containing information about the available servers |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1 | Rowsc2Servers | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.1 | Columnsc2srvUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.2 | Columnsc2srvPhysicalMemory | read-only | mandatory | Size of physical main memory installed (MBytes) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.3 | Columnsc2srvLastBootResult | read-only | mandatory | Result of last system boot |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.4 | Columnsc2srvCurrentBootStatus | read-only | mandatory | Status of the current boot |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.5 | Columnsc2srvShutdownCommand | read-write | mandatory | Shutdown the server and switch off or reset; a delay (see object below) can be defined before the command is being executed; when reading that value, always un… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.6 | Columnsc2srvShutdownDelay | read-write | mandatory | Delay time (seconds) the agent waits before executing the shutdown command (see previous command). 0 = immediate action, no delay -1 = unknown (delay not suppo… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.7 | Columnsc2srvUUID | read-only | mandatory | Universal Unique ID (UUID) number (as specified in RFC 4122; shown in network byte order, big-endian) - this is a world-wide unique ID number of the server. Ca… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.8 | Columnsc2srvPhysicalMemoryOs | read-only | mandatory | Size of physical main memory available to the operating system (MBytes). This value is similar to 'sc2srvPhysicalMemory', but may be less if the system has mir… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.9 | Columnsc2srvUUIDWireFormat | read-only | mandatory | Universal Unique ID (UUID) number (shown in the wire format; little-endian for the first three fields, as consistently used in the PC industry) - this is a wor… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.10 | Columnsc2srvOsPlatform | read-only | mandatory | Reports about the current operating system platform (x86, x64) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.11 | Columnsc2srvBiosVersion | read-only | mandatory | System BIOS version |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.12 | Columnsc2srvHasEncryptedPartitions | read-only | mandatory | Specifies whether encrypted file systems (e.g. by Windows BitLocker) are used (may prevent from BIOS updates) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.1.1.13 | Columnsc2srvTrustedExecutionTechnologyEnabled | read-only | mandatory | Specifies whether Intel Trusted Execution Technology (TXT) is enabled (may prevent from BIOS updates) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2 | Tablesc2UnitPowerOnOffTable | not-accessible | mandatory | Unit power-on and -off information |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1 | Rowsc2UnitPowerOnOff | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.1 | Columnsc2ooUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.2 | Columnsc2PowerOnOffStatus | read-only | mandatory | Current power on/off status |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.3 | Columnsc2LastPowerOffSource | read-only | mandatory | Reason why the system was switched off last time |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.4 | Columnsc2LastPowerOnSource | read-only | mandatory | Source the system was switched on from |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.5 | Columnsc2LastPowerOnTime | read-only | mandatory | Time and date (UTC) the system was booted (seconds since 1/1/1970; 0 = unknown or not available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.6 | Columnsc2PowerOnCounts | read-only | mandatory | Tells how often the server was switched on in its life (0 = unknown or not available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.7 | Columnsc2PowerOnDuration | read-only | mandatory | Tells how long the system has stayed ON in its life (in seconds; 0 = unknown or not available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.8 | Columnsc2PowerOffDuration | read-only | mandatory | Tells how long the system has stayed OFF in its life (in seconds; 0 = unknown or not available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.9 | Columnsc2PowerFailRecovery | read-only | mandatory | Action on AC power recovery after AC has failed. not-available(2) : function not available, behavior is hardware-defined. as-before(3) : server gets the same p… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.10 | Columnsc2PowerCommand | read-write | mandatory | Switch the unit on or off; mainly used for extension cabinets; argument tells what kind of action: on: switch power on off: switch power off power-cycle: switc… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.11 | Columnsc2PowerSupplyRedundancy | read-only | mandatory | Specifies whether the power supply system contains redundant power supplies and whether redundancy is available |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.2.1.12 | Columnsc2PowerSupplyMatchStatus | read-only | mandatory | Status of power supply matching - 'ok' if power supplies do not mismatch |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.3 | Tablesc2PerformanceTable | not-accessible | mandatory | Server performance and utilisation information (Obsolete! Please use sc2PerformanceValueTable!) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1 | Rowsc2Performance | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.1 | Columnsc2perfUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.2 | Columnsc2perfNr | read-only | mandatory | Server performance entry number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.3 | Columnsc2PerformanceType | read-only | mandatory | Server performance object type (description see below) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.4 | Columnsc2PerformanceObjectNr | read-only | mandatory | Server performance object number (0..n; for types with multiple objects) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.5 | Columnsc2PerformanceName | read-only | mandatory | Name (short description) of the performance value (e.g. 'CPU1'). Can be used for displaying a list of performance values in the management frontend. |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.3.1.6 | Columnsc2PerformanceValue | read-only | mandatory | Server performance value (value interpretation depending on type; 0xffffffff = unknown): cpu: Load of a single CPU in percent cpu-overall: Overall CPU load in … |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.4 | Tablesc2TimerOnOffTable | not-accessible | mandatory | Power on/off timer table |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1 | Rowsc2TimerOnOff | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.1 | Columnsc2tooUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.2 | Columnsc2tooDayOfWeek | read-only | mandatory | Day of the week the times should act upon (index); 1=Sunday, 2=Monday... |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.3 | Columnsc2OnTime | read-write | mandatory | Time the system should be switched on (by the real-time clock; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 are allowed. |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.4.1.4 | Columnsc2OffTime | read-write | mandatory | Time the system should be switched off (by the real-time clock of software; in minutes since midnight; -1 = disabled, no on time). Only values -1 and 0..1439 a… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5 | Tablesc2PowerMonitoringTable | not-accessible | mandatory | Power monitoring table |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1 | Rowsc2PowerMonitoring | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.1 | Columnsc2pmUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.2 | Columnsc2pmCurrentPowerMonitoringAvailable | read-only | mandatory | Power monitoring and control available on this server: true: Power monitoring and power control is available false: Power monitoring and power control is not a… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.3 | Columnsc2pmCurrentPowerMonitoringEnabled | read-only | mandatory | Power monitoring enable value: true: Power monitoring and data gathering is enabled false: Power monitoring and data gathering is disabled or not available |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.4 | Columnsc2pmNominalPowerConsumption | read-only | mandatory | Nominal (maximum) value of the system's power consumption (in Watts; -1 if value not available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.5 | Columnsc2pmCurrentPowerConsumption | read-only | mandatory | Current value of the system's power consumption (in Watts; -1 if value not available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.6 | Columnsc2pmCurrentPowerControl | read-only | mandatory | Power mode control value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard management … |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.7 | Columnsc2pmPowerLimitStatus | read-only | mandatory | Power limitation status (valid if power control = limited) ok: power consumption is within specified range warning: power consumption is above warning threshol… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.8 | Columnsc2pmPowerLimitThreshold | read-only | mandatory | Maximum limit value of the system's power consumption (in Watts; -1 if value not available; only valid if limiting enabled) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.9 | Columnsc2pmPowerLimitWarning | read-only | mandatory | Warning limit level (in percent of the maximum limit threshold; 0 if value not available; only valid if limiting enabled) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.10 | Columnsc2pmRedundancyCritLevel | read-only | mandatory | Upper critical power consumption level (in Watts; -1 if value not available); power supply redundancy lost if level is exceeded |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.11 | Columnsc2pmPowerControlMode | read-only | mandatory | Configured power control mode value: disabled: The baseboard management controller does not control the power saving behaviour best-performance: The baseboard … |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.5.1.12 | Columnsc2pmPowerDisplayUnit | read-only | mandatory | Configurd unit for the display of power consumption values: Watt: Power consumption values are displayed in Watts Btu/h: Power consumption values are displyed … |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.6 | Tablesc2UtilizationHistoryTable | not-accessible | mandatory | Utilization history table (for power consumption); table only contains existing values (no values for non-existing values) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1 | Rowsc2UtilizationHistory | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.1 | Columnsc2uthUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.2 | Columnsc2uthEntity | read-only | mandatory | Utilization value entity; describes what kind of value to be requested: powerConsumptionDay: power consumption values of the last 24 hours; one value (Watts) p… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.3 | Columnsc2uthTimeStamp | read-only | mandatory | Time stamp of the currenty history entry (time_t = seconds since 1/1/1970, 0:00 AM as GMT) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.4 | Columnsc2uthHardwareUUID | read-only | mandatory | UUID of the hardware instance that delivered the value (from object sc2srvUUID); may change if an installation is migrated to another hardware (e.g. in blade e… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.5 | Columnsc2uthAverageValue | read-only | mandatory | Average value (in Watts) within the monitored time period (minute, hour, day) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.6 | Columnsc2uthMinValue | read-only | mandatory | Minimum (lowest) value within the monitored time period |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.6.1.7 | Columnsc2uthMaxValue | read-only | mandatory | Maximum (highest) value within the monitored time period |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.7 | Tablesc2PowerSourceInformationTable | not-accessible | mandatory | Power source information table |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1 | Rowsc2PowerSourceInformation | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.1 | Columnsc2psiUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.2 | Columnsc2psiPowerSourceType | read-only | mandatory | System input power source type (e.g. 'AC', 'DC') |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.3 | Columnsc2psiPowerSourcePhase | read-only | mandatory | System input phase of power source. |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.7.1.4 | Columnsc2psiPowerSourceVoltage | read-only | mandatory | System nominal input voltage of power source (in Volts; -1 if value not available). |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.8 | Tablesc2VirtualIoManagerTable | not-accessible | mandatory | Virtual I/O Manager (VIOM) information table |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1 | Rowsc2VirtualIoManager | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.1 | Columnsc2viomUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.2 | Columnsc2viomCurrentManagerId | read-only | mandatory | Identification string of the VIOM manager that currently manages this server |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.3 | Columnsc2viomEnabled | read-only | mandatory | True if the server is enabled for VIOM |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.4 | Columnsc2viomBiosSupport | read-only | mandatory | True if the BIOS supports VIOM |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.8.1.5 | Columnsc2viomConnectionStatus | read-only | mandatory | The connection status for VIOM - bit field: Bit 0 - waiting for VIOM table Bit 1 - waiting for inventory table Bit 2 - waiting for external power-on event |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.9 | Tablesc2PowerSupplyRedundancyConfigurationTable | not-accessible | mandatory | Power Supply redundancy configuration table |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1 | Rowsc2PowerSupplyRedundancyConfiguration | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.1 | Columnsc2PSRedUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.2 | Columnsc2PSRedundancyMode | read-only | mandatory | Configured power supply redundancy mode; configured in Server Configuration |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.3 | Columnsc2PSRedundancyModeConfig | read-only | mandatory | Configuration of number required power supplies for the different redundancy modes specified in sc2PSRedundancyMode: no-redundancy(2): no redundancy required r… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.4 | Columnsc2PSRedundancyRequiredPowerSupplies | read-only | mandatory | Number of power supplies required for configured redundancy mode |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.5 | Columnsc2PSRedundancyPopulatedPowerSupplies | read-only | mandatory | Number of power supplies populated for configured redundancy mode |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.6 | Columnsc2PSRedundancyConfigurationStatus | read-only | mandatory | Status of the redundancy configuration; reports the status about whether enough power supplies are installed to operate at the configured redundancy mode |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.7 | Columnsc2PSRedundancyThresholdStatus | read-only | mandatory | Status of redundancy threshold; reports the status about whether the actual power consumption exceeds the maximum power consumption level for the configured re… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.9.1.8 | Columnsc2PSRedundancyStatus | read-only | mandatory | Status of power supply redundancy; similar to sc2PowerSupplyRedundancy, but with additional status evaluation according to the power supply redundancy configur… |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.10 | Tablesc2PerformanceValueTable | not-accessible | mandatory | Server performance and utilisation values |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1 | Rowsc2PerformanceValues | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.1 | Columnsc2PerfValUnitId | read-only | mandatory | Unit identifier (index, 1..n). For performacne values on local system use 1! |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.2 | Columnsc2PerfValType | read-only | mandatory | Server performance object type (description see below) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.3 | Columnsc2PerfValObjectNr | read-only | mandatory | Server performance object number (1..n; for types with multiple objects) |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.4 | Columnsc2PerfValName | read-only | mandatory | Name (short description) of the performance value (e.g. 'CPU1'). Can be used for displaying a list of performance values in the management frontend. |
| 1.3.6.1.4.1.231.2.10.2.2.10.4.10.1.5 | Columnsc2PerfValCurrentValue | read-only | mandatory | Server performance value (value interpretation depending on type; 0xffffffff = unknown): physicalMemoryUsageMb: Physical memory usage in MBytes physicalMemoryU… |
| 1.3.6.1.4.1.231.2.10.2.2.10.5 | Nodesc2Environment | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.5.1 | Tablesc2TemperatureSensorTable | not-accessible | mandatory | Temperature sensors |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1 | Rowsc2TemperatureSensors | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.1 | Columnsc2tempUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.2 | Columnsc2tempSensorNr | read-only | mandatory | Temperature sensor number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.3 | Columnsc2tempSensorDesignation | read-only | mandatory | Temperature sensor designation (e.g. TEMP-PS1) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.4 | Columnsc2tempSensorIdentifier | read-only | mandatory | Temperature sensor identification string (e.g. TEMP-RSB1) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.5 | Columnsc2tempSensorStatus | read-only | mandatory | Status of the temperature sensor |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.6 | Columnsc2tempCurrentTemperature | read-only | mandatory | Current temperature at this sensor (degrees Celsius; 0 if unknown or sensor failed) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.7 | Columnsc2tempWarningLevel | read-only | mandatory | Maximum temperature - warning level (degrees Celsius; 0 if unknown or undefined) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.8 | Columnsc2tempCriticalLevel | read-only | mandatory | Maximum temperature - critical level (degrees Celsius; 0 if unknown or undefined), system shutdown may occur if this level is exceeded |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.1.1.9 | Columnsc2tempCriticalReaction | read-write | mandatory | Reaction if temperature exceeds the critical level (the value unknown(1) cannot be set) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.2 | Tablesc2FanTable | not-accessible | mandatory | Cooling devices (fans, liquid cooling pumps) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1 | Rowsc2Fans | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.1 | Columnsc2fanUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.2 | Columnsc2fanNr | read-only | mandatory | Cooling device number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.3 | Columnsc2fanDesignation | read-only | mandatory | Cooling device designation (e.g. FAN-PS1) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.4 | Columnsc2fanIdentifier | read-only | mandatory | Cooling device identification string (e.g. FAN-1-POWERSUPPLY) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.5 | Columnsc2fanStatus | read-only | mandatory | Status of the cooling device |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.6 | Columnsc2fanCurrentSpeed | read-only | mandatory | Current cooling device speed (revolutions per minute; 0 if unknown or failed) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.7 | Columnsc2fanQuality | read-only | mandatory | Quality of cooling device (in percent of nominal speed - measured at full speed) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.8 | Columnsc2fanFailReaction | read-write | mandatory | Reaction if the cooling device fails (the value unknown(1) cannot be set) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.9 | Columnsc2fanFailShutdownDelay | read-write | mandatory | Delay time (in seconds) when shutdown should commit on cooling device fail (if shutdown-and-off is configured; 0 = immediately, -1 = unknown, cannot be set) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.2.1.10 | Columnsc2fanCoolingDeviceType | read-only | mandatory | Type of cooling device (whether fan or liquid cooling pump) fan(2): fan liquid(3): liquid cooling pump |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.3 | Tablesc2AirflowTable | not-accessible | mandatory | Exhaust airflow volume table |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1 | Rowsc2Airflow | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.1 | Columnsc2afUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.2 | Columnsc2afExhaustAirflowVolume | read-only | mandatory | System exhaust airflow volume ('-1' if value not available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.5.3.1.3 | Columnsc2afExhaustAirflowVolumeUnit | read-only | mandatory | System exhaust airflow volume unit (e.g. 'cbm/h', 'ccm/min', ...) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6 | Nodesc2Hardware | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.6.1 | Tablesc2SystemBoardTable | not-accessible | mandatory | System board (main board) information |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1 | Rowsc2SystemBoard | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.1 | Columnsc2sbUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.2 | Columnsc2sbBoardNr | read-only | mandatory | System board number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.3 | Columnsc2SystemBoardModelName | read-only | mandatory | Model name (e.g. 'D1297') |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.4 | Columnsc2SystemBoardProductNumber | read-only | mandatory | Product number (may be identical to ModelName) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.5 | Columnsc2SystemBoardRevision | read-only | mandatory | Revision string (e.g. 'WGS1 GS3') |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.6 | Columnsc2SystemBoardSerialNumber | read-only | mandatory | Serial number (not available for all boards) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.7 | Columnsc2SystemBoardDesignation | read-only | mandatory | Designation (important when multiple system boards are available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.1.1.8 | Columnsc2SystemBoardSDCardSlotPresent | read-only | mandatory | System board contains SD card slot |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.2 | Tablesc2PowerSupplyTable | not-accessible | mandatory | Power supplies |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1 | Rowsc2PowerSupply | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.1 | Columnsc2psUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.2 | Columnsc2psPowerSupplyNr | read-only | mandatory | Power supply (bay) number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.3 | Columnsc2PowerSupplyDesignation | read-only | mandatory | Power supply designation (e.g. PS1) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.4 | Columnsc2PowerSupplyIdentifier | read-only | mandatory | Power supply identification string (e.g. PS1) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.5 | Columnsc2PowerSupplyStatus | read-only | mandatory | Power supply status |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.6 | Columnsc2psPowerSupplyLoad | read-only | mandatory | Actual power supply output load in Watts (0 = not available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.2.1.7 | Columnsc2psPowerSupplyNominal | read-only | mandatory | Nominal power supply output load in Watts (0 = not available), the maximum value the power supply can provide |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.3 | Tablesc2VoltageTable | not-accessible | mandatory | Voltages - all voltage values are in 1/100th Volts; a value of 330 means 3.30 Volts (0xffffffff = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1 | Rowsc2Voltages | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.1 | Columnsc2voUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.2 | Columnsc2voSensorNr | read-only | mandatory | Voltage sensor number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.3 | Columnsc2VoltageDesignation | read-only | mandatory | Voltage designation string (e.g. 12V, 3V3, ...) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.4 | Columnsc2VoltageStatus | read-only | mandatory | Voltage status not-available(2): no voltage available (e.g. CPU voltage on empty CPU socket) ok(3): voltage value is in normal range too-low(4): voltage value … |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.5 | Columnsc2VoltageCurrentValue | read-only | mandatory | Voltage current value (in mV; 0xFFFFFFFF = unknown; negative voltages are reported as negative values: -1770 (0xFFFFF916) means -1.77 Volts) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.6 | Columnsc2VoltageNominalValue | read-only | mandatory | Voltage nominal value (in mV; -1 = unknown; negative voltages are reported as negative values) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.7 | Columnsc2VoltageMinimumLevel | read-only | mandatory | Voltage minimum level (in mV; -1 = unknown; negative voltages are reported as negative values) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.8 | Columnsc2VoltageMaximumLevel | read-only | mandatory | Voltage maximum level (in mV; -1 = unknown; negative voltages are reported as negative values) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.3.1.9 | Columnsc2VoltageCurrentLoad | read-only | mandatory | Current output load on this voltage line, in percent of the maximum load (0xFFFFFFFF = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4 | Tablesc2CPUTable | not-accessible | mandatory | CPU description table |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1 | Rowsc2CPUs | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.1 | Columnsc2cpuUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.2 | Columnsc2cpuNr | read-only | mandatory | CPU (socket) number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.3 | Columnsc2cpuDesignation | read-only | mandatory | CPU designation (e.g. CPU-2) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.4 | Columnsc2cpuStatus | read-only | mandatory | CPU status: unknown(1): CPU status could not be evaluated not-present(2): CPU socket is empty ok(3): CPU is available and working properly disabled(4): CPU was… |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.5 | Columnsc2cpuModelName | read-only | mandatory | CPU model name (e.g. Pentium Xeon) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.6 | Columnsc2cpuManufacturer | read-only | mandatory | CPU manufacturer name (e.g. Intel) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.7 | Columnsc2cpuStep | read-only | mandatory | CPU step / revision |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.8 | Columnsc2cpuCurrentSpeed | read-only | mandatory | CPU speed (frequency in MHz, -1 if unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.9 | Columnsc2cpuNumberLogicals | read-only | mandatory | Number of (physically available) logical CPUs within one physical CPU (for hyper-threading and multi-core CPUs). This is the sum of all cores and all logical C… |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.10 | Columnsc2cpuCacheL1Size | read-only | mandatory | Size of first level cache (in kBytes, 0 if unknown or not available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.11 | Columnsc2cpuCacheL2Size | read-only | mandatory | Size of second level cache (in kBytes, 0 if unknown or not available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.12 | Columnsc2cpuCacheL3Size | read-only | mandatory | Size of third level cache (in kBytes, 0 if unknown or not available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.13 | Columnsc2cpuNumberCores | read-only | mandatory | Number of (physically available) cores within one physical CPU (for multi-core CPUs, platform dependent), 0 if unknown or not available |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.14 | Columnsc2cpuFamily | read-only | mandatory | CPU family code. This enumerated value is specified by the DMTF SMBIOS specification (processor information, type 4). |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.15 | Columnsc2cpuEnabledCores | read-only | mandatory | Number of effectively enabled cores within one physical CPU (for multi-core CPUs; 0 if unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.16 | Columnsc2cpuMultithreadingEnabled | read-only | mandatory | Multithreading of CPU enabled |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.17 | Columnsc2cpuConfigurationStatus | read-only | mandatory | CPU configuration status: unknown(1): CPU status could not be evaluated normal(2): Regular CPU configuration disabledManually(3): CPU was manually disabled (in… |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.18 | Columnsc2cpuMCDRAMSize | read-only | mandatory | Size of the onboard MCDRAM (GByte; 0 if no MCDRAM is available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.19 | Columnsc2cpuMCDRAMSpeed | read-only | mandatory | Speed of the onboard MCDRAM (MT/s; 0 if no MCDRAM is available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.20 | Columnsc2cpuMCDRAMMode | read-only | mandatory | Operation mode of the onboard MCDRAM: undefined(1): Mode is not defined (no MCDRAM available) flat(2): MCDRAM is used as standalone memory exclusively or in ad… |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.21 | Columnsc2cpuMCDRAMCacheSize | read-only | mandatory | Portion of the onboard MCDRAM used as a cache in hybrid mode (in percent; 0 if no MCDRAM is available or other mode than hybrid) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.4.1.22 | Columnsc2cpuMCDRAMMemoryModel | read-only | mandatory | Memory model of the onboard MCDRAM: undefined(1): Model is not defined (no MCDRAM available) all2all(2): All2All subNumaCluster2(3): Sub NUMA Cluster - 2 subNu… |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5 | Tablesc2MemoryModuleTable | not-accessible | mandatory | Main memory module table |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1 | Rowsc2MemoryModules | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.1 | Columnsc2memUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.2 | Columnsc2memModuleNr | read-only | mandatory | Memory module (socket) number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.3 | Columnsc2memModuleDesignation | read-only | mandatory | Memory module designation (e.g. DIMM-2) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.4 | Columnsc2memModuleStatus | read-only | mandatory | Memory module status: unknown(1): Module status could not be evaluated not-present(2): Module socket is empty ok(3): Module is available and working properly d… |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.5 | Columnsc2memModuleBank | read-only | mandatory | Memory module bank number (-1 if unknown) Due to the fact that modern mainboards do no longer have fixed banks, this value is OBSOLETE! |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.6 | Columnsc2memModuleCapacity | read-only | mandatory | Memory module size (capacity in MBytes; -1 if unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.7 | Columnsc2memModuleStartAddress | read-only | mandatory | Memory module start address (in MBytes; -1 if unknown) Due to the fact that modern mainboards do no longer show start addresses, this value is OBSOLETE! |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.8 | Columnsc2memModuleForm | read-only | mandatory | Memory module form (SIMM, DIMM, ...) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.9 | Columnsc2memModuleType | read-only | mandatory | Memory module type (SDRAM, DDRAM, DDR2, DDR3, ...) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.10 | Columnsc2memModuleCorrErrors | read-only | mandatory | Number of memory module correctable errors (-1 if unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.11 | Columnsc2memModuleUncorrErrors | read-only | mandatory | Number of memory module uncorrectable errors (-1 if unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.12 | Columnsc2memModuleApproved | read-only | mandatory | Memory module approved for this machine |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.13 | Columnsc2memModuleConfiguration | read-only | mandatory | Memory module configuration: unknown(1): Module configuration could not be evaluated normal(2): Module is in normal non-redundant configuration or slot is empt… |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.14 | Columnsc2memModuleFrequency | read-only | mandatory | Memory module actual front side bus frequency (in MHz; -1 if unknown). This value is based on the BIOS settings |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.15 | Columnsc2memModuleMaxFrequency | read-only | mandatory | Memory module maximum front side bus frequency (in MHz; -1 if unknown). This value is based on memory module SPD data |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.5.1.16 | Columnsc2memModuleVoltInterface | read-only | mandatory | Memory module interface voltage interface description |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.6 | Scalarsc2cpuMultithreadEnable | read-only | mandatory | Multithreading of CPU enabled This object is OBSOLETE for future implementations; use object 'sc2cpuMultithreadingEnabled' from 'sc2CPUTable' instead! |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.7 | Tablesc2ComponentPowerConsumptionTable | not-accessible | mandatory | Table of component power consumption data |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1 | Rowsc2ComponentPowerConsumption | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.1 | Columnsc2cpcUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.2 | Columnsc2cpcComponentClass | read-only | mandatory | Component class enumeration (based on IPMI v1.0 entity ID) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.3 | Columnsc2cpcComponentIndex | read-only | mandatory | Component index within class (1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.4 | Columnsc2cpcDesignation | read-only | mandatory | Component designation |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.7.1.5 | Columnsc2cpcCurrentValue | read-only | mandatory | Current component power consumption in Watts |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.8 | Tablesc2TrustedPlatformModuleTable | not-accessible | mandatory | Trusted Platform Module (TPM) status information (see corresponding TPM specification for detailed description of these states) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1 | Rowsc2TrustedPlatformModule | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.1 | Columnsc2tpmUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.2 | Columnsc2tpmHardwareAvailable | read-only | mandatory | TPM hardware is available ('unknown' if hardware availability cannot be detected; no interface found) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.3 | Columnsc2tpmBiosEnabled | read-only | mandatory | TPM hardware is enabled by BIOS ('unknown' if hardware is not available; a reboot is required to change this value) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.4 | Columnsc2tpmEnabled | read-only | mandatory | TPM is enabled (by software; cannot take ownership if disabled; 'unknown' if hardware is not available or disabled) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.5 | Columnsc2tpmActivated | read-only | mandatory | TPM is activated (by software; 'unknown' if hardware is not available or disabled) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.8.1.6 | Columnsc2tpmOwnership | read-only | mandatory | TPM ownership is established (valid endorsement key is existing; 'unknown' if hardware is not available or disabled) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9 | Tablesc2PersistentMemoryModuleTable | not-accessible | mandatory | Additional information about persistent (non-volatile) memory modules to extend the sc2MemoryModuleTable. This table uses the index numbers of the previous sc2… |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1 | Rowsc2PersistentMemoryModules | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.1 | Columnsc2nvmemMemoryModeEnabled | read-only | mandatory | Volatime memory mode is enabled |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.2 | Columnsc2nvmemPersistentModeEnabled | read-only | mandatory | Persistent memory mode is enabled |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.3 | Columnsc2nvmemPackageSparingCapable | read-only | mandatory | Module is capable of providing spare memory |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.4 | Columnsc2nvmemEncryptionEnabled | read-only | mandatory | Memory encryption is enabled |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.5 | Columnsc2nvmemFirmwareRevision | read-only | mandatory | Firmware revision |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.6 | Columnsc2nvmemTotalSize | read-only | mandatory | Total size of memory module (in GBytes; including reserved spare space) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.7 | Columnsc2nvmemRawCapacity | read-only | mandatory | Maximum capacity that can be allocated for use in any of the supported modes (in GBytes; excluding reserved space) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.8 | Columnsc2nvmemVolatileCapacity | read-only | mandatory | Capacity of volatile memory (in GBytes) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.9 | Columnsc2nvmemPersistentCapacity | read-only | mandatory | Capacity of persistent memory (in GBytes) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.10 | Columnsc2nvmemVolatilePercent | read-only | mandatory | Capacity of volatile memory (in percent of total size) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.11 | Columnsc2nvmemPersistentPercent | read-only | mandatory | Capacity of persistent memory (in percent of total size) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.12 | Columnsc2nvmemVolatileStart | read-only | mandatory | Start address of the volatile memory region |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.13 | Columnsc2nvmemPersistentStart | read-only | mandatory | Start address of the persistent memory region |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.14 | Columnsc2nvmemHealthStatusNonCritical | read-only | mandatory | Non-critical (warning) status |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.15 | Columnsc2nvmemHealthStatusCritical | read-only | mandatory | Critical status |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.16 | Columnsc2nvmemHealthStatusFatal | read-only | mandatory | Fatal error status (data loss has occurred or is imminent) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.17 | Columnsc2nvmemPowerOnTime | read-only | mandatory | Lifetime the DIMM has been powered on (in seconds) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.18 | Columnsc2nvmemUpTime | read-only | mandatory | Current uptime of the DIMM for the current power cycle (in seconds) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.19 | Columnsc2nvmemLiftetimeRemaining | read-only | mandatory | Remaining predicted lifetime (in seconds; -1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.20 | Columnsc2nvmemAveragePowerBudget | read-only | mandatory | Average Power Budget in mW |
| 1.3.6.1.4.1.231.2.10.2.2.10.6.9.1.21 | Columnsc2nvmemPeakPowerBudget | read-only | mandatory | Peak Power Budget in mW |
| 1.3.6.1.4.1.231.2.10.2.2.10.7 | Nodesc2Recovery | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.7.1 | Tablesc2MessageLogTable | not-accessible | mandatory | Error and event message handling |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1 | Rowsc2MessageLogs | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.1 | Columnsc2msgUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.2 | Columnsc2msgLogEntryNr | read-only | mandatory | Message log entry number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.1.1.3 | Columnsc2msgLogEntryData | read-only | mandatory | Message log entry data (binary; one message per table entry) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.2 | Tablesc2WatchdogTable | not-accessible | mandatory | Watchdogs |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1 | Rowsc2Watchdogs | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.1 | Columnsc2wdUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.2 | Columnsc2WatchdogType | read-only | mandatory | Watchdog type |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.3 | Columnsc2WatchdogStatus | read-only | mandatory | Watchdog status |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.4 | Columnsc2WatchdogTime | read-only | mandatory | Watchdog timeout period in seconds (-1 = unknown) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.2.1.5 | Columnsc2WatchdogAction | read-only | mandatory | Watchdog timeout action; the value unknown(1) can't be written. Not all watchdog type allow setting all of the values (-> BADVALUE). |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.3 | Tablesc2RecoverySettingTable | not-accessible | mandatory | ASR&R (Automatic server recovery and restart) settings |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1 | Rowsc2RecoverySettings | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.1 | Columnsc2asrUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.2 | Columnsc2asrNrRebootRetries | read-only | mandatory | Current number of retries to reboot/restart the server when a failure shutdown (and power-off) had occured. After this number of retries the action defined in … |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.3 | Columnsc2asrDefaultRebootRetries | read-only | mandatory | Default number of retries for server failure reboot. The above object 'sc2asrNrRebootRetries' will be set to this value after the server is working properly fo… |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.4 | Columnsc2asrNextBootSource | read-only | mandatory | Source medium to boot from (next time): operating-system: boot from floppy or hard disk diag-system: boot from alternate diagnostic system (only for SCSI syste… |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.5 | Columnsc2asrRebootFailAction | read-only | mandatory | Specifies the action after a specified number of failed reboot retries (the object 'sc2asrNrRebootRetries' has reached zero). The value no-diag-system(4) means… |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.6 | Columnsc2asrRestartDelay | read-only | mandatory | Delay (in minutes) after that the system should be automatically switched on again (by real-time clock) after an error power-off. Setting this value to zero me… |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.3.1.7 | Columnsc2asrPostErrorHalt | read-only | mandatory | Describes what to do when a POST error has occured (halt on any error, no halt on any error...). |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.4 | Tablesc2MessageTextLogTable | not-accessible | mandatory | Error and event message handling, reported as text strings |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1 | Rowsc2MessageTextLogs | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.1 | Columnsc2msgTextLogUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.2 | Columnsc2msgTextLogLanguage | read-only | mandatory | Message log entry language (index, Windows language code) e.g. 1031, 1033 for German, English (default; always available) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.3 | Columnsc2msgTextLogSeqNr | read-only | mandatory | Message log entry sequence number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.4 | Columnsc2msgTextLogTimestamp | read-only | mandatory | Message log entry time stamp (time_t = seconds since 1/1/1970, 0:00 AM as GMT) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.5 | Columnsc2msgTextLogMessage | read-only | mandatory | Message log entry message string (multi-byte string; multi-language; not every language may be implemented) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.6 | Columnsc2msgTextLogErrorCode | read-only | mandatory | Message log entry error code |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.7 | Columnsc2msgTextLogSeverity | read-only | mandatory | Message log entry severity |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.4.1.8 | Columnsc2msgTextLogCSSComponent | read-only | mandatory | Component which caused the log message may be replaced by the customer (CSS=Customer Self Service) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.5 | Tablesc2MessageLogActionHintTable | not-accessible | mandatory | Action text strings for error and event messages |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1 | Rowsc2MessageLogActionHints | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.1 | Columnsc2mlaLanguage | read-only | mandatory | Action text language (index, Windows language code) e.g. 1031, 1033 for German, English |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.2 | Columnsc2mlaErrorCode | read-only | mandatory | Action text error code (index) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.3 | Columnsc2mlaType | read-only | mandatory | Message log entry severity |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.4 | Columnsc2mlaIndex | read-only | mandatory | Action text entry string index (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.7.5.1.5 | Columnsc2mlaMessage | read-only | mandatory | Action message string |
| 1.3.6.1.4.1.231.2.10.2.2.10.8 | Nodesc2Status | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.8.1 | Scalarsc2AgentStatus | read-only | mandatory | Overall status of all monitored components in this agent ok(1): all components are working properly; no warnings, no errors warning(2): at least one component … |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.2 | Tablesc2StatusComponentTable | not-accessible | mandatory | Table with status values of the components in this agent. The table summarizes all instances of one component to one status value. |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1 | Rowsc2StatusComponents | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.1 | Columnsc2csUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.2 | Columnsc2csStatusOverall | read-only | mandatory | Overall status (worst status of all components) in this unit |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.3 | Columnsc2csStatusBoot | read-only | mandatory | Boot status (errors from power-on selftest and boot) |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.4 | Columnsc2csStatusPowerSupply | read-only | mandatory | Power supply status |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.5 | Columnsc2csStatusTemperature | read-only | mandatory | Temperature status |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.6 | Columnsc2csStatusFans | read-only | mandatory | Fan status |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.7 | Columnsc2csStatusVoltages | read-only | mandatory | Voltage status |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.8 | Columnsc2csStatusCpu | read-only | mandatory | CPU status |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.2.1.9 | Columnsc2csStatusMemoryModule | read-only | mandatory | Memory module status |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.3 | Tablesc2ComponentStatusSensorTable | not-accessible | mandatory | This table contains the component status sensor table of the BMC (baseboard management controller). Additionally it also holds the CSS (Customer Self Service) … |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1 | Rowsc2ComponentStatusSensors | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.1 | Columnsc2cssUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.2 | Columnsc2cssSensorNumber | read-only | mandatory | BMC component status sensor number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.3 | Columnsc2cssSensorDesignation | read-only | mandatory | Component status sensor designation string |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.4 | Columnsc2cssSensorDevice | read-only | mandatory | Name of device (entity) the component status sensor belongs to |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.5 | Columnsc2cssSensorDeviceInstance | read-only | mandatory | Instance number of device (entity) the component status sensor belongs to |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.6 | Columnsc2cssSensorPhysicalLed | read-only | mandatory | If set, component has a physical status LED showing the sensor status |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.7 | Columnsc2cssSensorCssComponent | read-only | mandatory | If set, component may be replaced by the customer (CSS 'custormer-self-service' component) |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.8 | Columnsc2cssSensorStatus | read-only | mandatory | Status returned by the component status sensor |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.3.1.9 | Columnsc2cssComponentServicePartId | read-only | mandatory | Spare part number of the replaceable component; used to create a link to the spare part list on the service's spare part catalogue. This usually is the compone… |
| 1.3.6.1.4.1.231.2.10.2.2.10.8.4 | Scalarsc2cssTableSize | read-only | mandatory | Number of entries in the component status sensor table |
| 1.3.6.1.4.1.231.2.10.2.2.10.9 | Nodesc2Maintenance | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.9.1 | Tablesc2MaintenanceObjectTable | not-accessible | mandatory | Table containing some other maintenance objects |
| 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1 | Rowsc2MaintenanceObjects | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.1 | Columnsc2mtUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.2 | Columnsc2ErrorCounterStartTime | read-only | mandatory | Memory module error counter start time (seconds since 1/1/1970, -1 if unknown). This is the time when the error counters were started or reset last time. |
| 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.3 | Columnsc2SendTestTrap | read-write | mandatory | Send a test trap (test alarm) to the manager application(s) to test connection and trap configuration; trap cannot be disabled. Initiate test trap sending by w… |
| 1.3.6.1.4.1.231.2.10.2.2.10.9.1.1.4 | Columnsc2AddTrapDestination | read-write | mandatory | Add the specified IP address (of the management station) to the trap destination list of this server. That client will become an alarm receiver for traps of th… |
| 1.3.6.1.4.1.231.2.10.2.2.10.9.2 | Tablesc2FirmwareVersionTable | not-accessible | mandatory | Controller firmware version table |
| 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1 | Rowsc2FirmwareVersions | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.1 | Columnsc2fwUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.2 | Columnsc2fwType | read-only | mandatory | Controller/firmware type |
| 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.3 | Columnsc2fwModelName | read-only | mandatory | Controller/firmware model name (e.g. 'Copernicus'...) |
| 1.3.6.1.4.1.231.2.10.2.2.10.9.2.1.4 | Columnsc2fwVersion | read-only | mandatory | Controller/firmware version string (e.g. '3.81.02') |
| 1.3.6.1.4.1.231.2.10.2.2.10.10 | Nodesc2Deployment | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1 | Tablesc2DeployInfoTable | not-accessible | mandatory | Table with data of deployment information. This table is OBSOLETE (no longer used for new implementations)! |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1 | Rowsc2DeployInfo | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.1 | Columnsc2dplInfoUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.2 | Columnsc2DeployInfoChassisId | read-only | mandatory | Chassis serial number |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.3 | Columnsc2DeployInfoMacAddr1 | read-only | mandatory | MAC address 1 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.4 | Columnsc2DeployInfoMacAddr2 | read-only | mandatory | MAC address 2 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.5 | Columnsc2DeployInfoMacAddr3 | read-only | mandatory | MAC address 3 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.6 | Columnsc2DeployInfoMacAddr4 | read-only | mandatory | MAC address 4 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.7 | Columnsc2DeployInfoIpAddr1 | read-write | mandatory | IP address 1 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.8 | Columnsc2DeployInfoIpAddr2 | read-write | mandatory | IP address 2 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.9 | Columnsc2DeployInfoIpAddr3 | read-write | mandatory | IP address 3 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.10 | Columnsc2DeployInfoIpAddr4 | read-write | mandatory | IP address 4 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.11 | Columnsc2DeployInfoNetMask1 | read-write | mandatory | IP subnet mask 1 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.12 | Columnsc2DeployInfoNetMask2 | read-write | mandatory | IP subnet mask 2 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.13 | Columnsc2DeployInfoNetMask3 | read-write | mandatory | IP subnet mask 3 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.14 | Columnsc2DeployInfoNetMask4 | read-write | mandatory | IP subnet mask 4 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.15 | Columnsc2DeployInfoGateway1 | read-write | mandatory | IP gateway 1 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.16 | Columnsc2DeployInfoGateway2 | read-write | mandatory | IP gateway 2 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.17 | Columnsc2DeployInfoGateway3 | read-write | mandatory | IP gateway 3 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.18 | Columnsc2DeployInfoGateway4 | read-write | mandatory | IP gateway 4 |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.19 | Columnsc2DeployInfoHostname | read-write | mandatory | Host name |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.20 | Columnsc2DeployInfoMasterImageReference | read-write | mandatory | URL in UNC notification (but in ASCII) to remote image file (with the extensions of *.img, *.cfg, *.txt) |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.21 | Columnsc2DeployInfoStatusOfBlade | read-write | mandatory | Status of this server: power-down(2): waiting for boot standby(3): power management mode system-boot-failure(4): system boot failure bios-setup(5): BIOS setup … |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.22 | Columnsc2DeployInfoLanStatusOfSlot | read-write | mandatory | Defines wether the IP-LAN definitions are valid or not. |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.23 | Columnsc2DeployInfoAutomaticRecovery | read-write | mandatory | Defines if this server blade should be provided automatic recovery. |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.24 | Columnsc2DeployInfoStatusOfCloning | read-write | mandatory | Status of current cloning process. |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.1.1.25 | Columnsc2DeployInfoBootMode | read-write | mandatory | Boot mode of the server for remote deployment: normal(2): boot from standard disk subsystem pxeBiosSetup(3): boot from PXE according to BIOS setup settings (fo… |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.2 | Tablesc2OemDeployInfoTable | not-accessible | mandatory | Table with data of server OEM information. This table is OBSOLETE (no longer used for new implementations)! |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1 | Rowsc2OemDeployInfo | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.1 | Columnsc2odplInfoUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.2 | Columnsc2odplParamId | read-only | mandatory | OEM parameter ID (index, 1..10) |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.2.1.3 | Columnsc2OemDeployInfoParamData | read-write | mandatory | OEM parameter data |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.3 | Tablesc2DeployLanInterfaceTable | not-accessible | mandatory | Table with system LAN interfaces information: This table lists all real LAN interfaces in same physical order as the BIOS uses it for PXE boot. Only on-board i… |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1 | Rowsc2DeployLanInterfaces | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.1 | Columnsc2dplLanUnitId | read-only | mandatory | Unit identifier (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.2 | Columnsc2dplLanInterfaceNr | read-only | mandatory | LAN interface number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.10.3.1.3 | Columnsc2dplLanMacAddress | read-only | mandatory | LAN interface hardware (MAC) address |
| 1.3.6.1.4.1.231.2.10.2.2.10.11 | Nodesc2DriverMonitoring | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.11.1 | Tablesc2DriverMonitorComponentTable | not-accessible | mandatory | Table of components monitored by the driver monitor. Foreign index sc2uUnitId is from sc2UnitTable. |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1 | Rowsc2DriverMonitorComponents | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.1 | Columnsc2drvmonCompClass | read-only | mandatory | Component class (index) |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.2 | Columnsc2drvmonCompIndex | read-only | mandatory | Component index (index, 1..n). This is an index over all component classes, but unit specific. |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.3 | Columnsc2drvmonCompName | read-only | mandatory | Name or designation of the component |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.4 | Columnsc2drvmonCompType | read-only | mandatory | Component (bus) type |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.5 | Columnsc2drvmonCompDriverName | read-only | mandatory | Name of the driver that created the event record |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.6 | Columnsc2drvmonCompLocationDesignation | read-only | mandatory | Device location designation (if it is an adapter or other hardware component); e.g. 'PCI Slot #2' or 'IOB#1-FUNC#0' |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.7 | Columnsc2drvmonCompLocationKey | read-only | mandatory | Device location key, used for identifying the component in other tables (like PCI device table); e.g. 'TYPE_PCI&BUS_3&DEV_14&FUNC_0' |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.8 | Columnsc2drvmonCompStatus | read-only | mandatory | Status of the component; caused by specific error events, reset by corresponding 'component OK' events or by manual acknowledge |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.1.1.9 | Columnsc2drvmonCompErrorAcknowledge | read-write | mandatory | Acknowledge an error condition (reset error or warning status) of the component by writing a non-zero value (reading this object just returns the value 0) |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.2 | Tablesc2DriverMonitorMessageTable | not-accessible | mandatory | Table of messages gathered by the driver monitor. The messages are based on the monitored operating system event log and are available in translated languages.… |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1 | Rowsc2DriverMonitorMessages | not-accessible | mandatory | |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.1 | Columnsc2drvmonMsgSeqNr | read-only | mandatory | Driver message entry sequence number (index, 1..n) |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.2 | Columnsc2drvmonMsgTimestamp | read-only | mandatory | Driver message entry time stamp (time_t = seconds since 1/1/1970, 0:00 AM as GMT) |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.3 | Columnsc2drvmonMsgMessage | read-only | mandatory | Message entry string (multi-language; not every language may be implemented, then English message has to be requested) |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.4 | Columnsc2drvmonMsgEventId | read-only | mandatory | Message entry error code (this code is a driver monitor specific error code) |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.5 | Columnsc2drvmonMsgSeverity | read-only | mandatory | Message entry severity (may be different from original event log severity) |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.6 | Columnsc2drvmonMsgErrorCode | read-only | mandatory | Message entry error code (must be used to get summary, causes and resolutions from sc2MessageLogActionHintTable table) |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.7 | Columnsc2drvmonOrigLogMessage | read-only | mandatory | Original operating system event log / syslog entry message (only available in the server's original language or in english, depending on the driver that create… |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.8 | Columnsc2drvmonOrigLogSource | read-only | mandatory | Original log entry source name |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.9 | Columnsc2drvmonOrigLogId | read-only | mandatory | Original log entry ID number (may not be available for some platforms/controllers, then ID = 0) |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.2.1.10 | Columnsc2drvmonOrigLogSeverity | read-only | mandatory | Original event log entry severity |
| 1.3.6.1.4.1.231.2.10.2.2.10.11.3 | Scalarsc2drvmonTableUpdateCount | read-only | mandatory | Counter defining the update revision of the driver monitoring tables. This counter is incremented with every change/update of the driver monitoring tables. |
| 1.3.6.1.4.1.231.2.10.2.2.10.20 | Nodesc2Notifications | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.1 | Nodesc2NotificationsTrapInfo | |||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.1.1 | Scalarsc2TrapInfoServerName | not-accessible | mandatory | Name of the server the trap comes from |
| 1.3.6.1.4.1.231.2.10.2.2.10.20.1.2 | Scalarsc2TrapInfoTime | not-accessible | mandatory | Time when the trap occured (in seconds since 01/01/1970 00:00h) |
| 1.3.6.1.4.1.231.2.10.2.2.10.20.1.3 | Scalarsc2TrapInfoCabinetNr | not-accessible | mandatory | Cabinet number generating the trap |
| 1.3.6.1.4.1.231.2.10.2.2.10.20.1.4 | Scalarsc2TrapInfoObjectDesignation | not-accessible | mandatory | Designation string for object that generated the trap (fan, temperature sensor...) |
| 1.3.6.1.4.1.231.2.10.2.2.10.20.1.5 | Scalarsc2TrapInfoString | not-accessible | mandatory | Additional string to be displayed in the trap text |
| 1.3.6.1.4.1.231.2.10.2.2.10.20.1.6 | Scalarsc2TrapInfoInteger | not-accessible | mandatory | Additional number to be displayed in the trap text |
| 1.3.6.1.4.1.231.2.10.2.2.10.20.1.7 | Scalarsc2TrapInfoInteger2 | not-accessible | mandatory | Additional number to be displayed in the trap text |
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2000 | Nodesc2TrapTest | Test trap to verify trap connection. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2001 | Nodesc2TrapCommunicationFailure | The communication with management controller failed! | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2002 | Nodesc2TrapCommunicationEstablished | The communication with the management controller was reestablished | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2003 | Nodesc2TrapControllerSelftestWarning | Controller selftest warning. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2004 | Nodesc2TrapControllerSelftestError | Controller selftest error. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2005 | Nodesc2TrapBiosSelftestError | A critical error happend while BIOS selftest. This error needs to be acknowledged to clear the error condition. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2006 | Nodesc2TrapSevereSystemError | The system was restarted after a severe problem. See server management message log (recovery log) for detailed information. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2010 | Nodesc2TrapFanAdded | The indicated hot-plug fan or liquid pump was inserted. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2011 | Nodesc2TrapFanRemoved | The indicated hot-plug fan or liquid pump was removed. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2012 | Nodesc2TrapFanOk | The indicated fan or liquid pump is working again. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2013 | Nodesc2TrapFanCritical | The indicated fan or liquid pump became critical | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2014 | Nodesc2TrapFanFailed | The indicated fan or liquid pump failed. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2015 | Nodesc2TrapRedundantFanFailed | The indicated redundant fan or liquid pump failed | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2020 | Nodesc2TrapTempOk | The temperature of the indicated sensor has decreased to the normal level. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2021 | Nodesc2TrapTempWarning | The temperature of the indicated sensor has reached the warning level. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2022 | Nodesc2TrapTempCritical | The temperature of the indicated sensor is out of tolerance range. The system will shut down and power off if shutdown is enabled. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2023 | Nodesc2TrapTempSensorOk | The indicated broken temperature sensor is OK again. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2024 | Nodesc2TrapTempSensorBroken | The indicated temperature sensor is broken. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2030 | Nodesc2TrapPowerSupplyAdded | One hot-replace power supply was added. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2031 | Nodesc2TrapPowerSupplyRemoved | One hot-replace power supply was removed | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2032 | Nodesc2TrapPowerSupplyOk | Power supply is working again. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2033 | Nodesc2TrapPowerSupplyCritical | Power supply status has become critical. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2034 | Nodesc2TrapPowerSupplyFailed | One hot-replace power supply failed. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2035 | Nodesc2TrapRedundantPowerSupplyFailed | One redundant hot-replace power supply failed | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2036 | Nodesc2TrapPowerSupplyRedundancyLost | Power supply redundancy no longer available. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2037 | Nodesc2TrapPowerSupplyCriticalTemperature | Critical temperature in power supply. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2038 | Nodesc2TrapPowerSupplyFanFailurePrediction | Fan failure prediction in power supply. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2039 | Nodesc2TrapPowerSupplyFanFailure | Fan failure in power supply. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2040 | Nodesc2TrapAcFail | Mains failed in the specified cabinet. This trap can only happen in storage extension cabinets without UPS or BBU. A server will not have time to send this tra… | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2041 | Nodesc2TrapDcFail | DC power failed in the specified cabinet. This is the result of the system's power-good sensor monitoring. The system may stop when this condition occurs. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2042 | Nodesc2TrapOnBattery | The server is operating on battery power - by UPS or backup battery unit (BBU). | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2043 | Nodesc2TrapOnMains | The mains voltage returned after a power failure. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2050 | Nodesc2TrapVoltageOk | Power supply voltage is within normal range again. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2051 | Nodesc2TrapVoltageTooLow | Power supply voltage is too low. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2052 | Nodesc2TrapVoltageTooHigh | Power supply voltage is too high. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2053 | Nodesc2TrapVoltageFailed | Power supply voltage is out of range. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2054 | Nodesc2TrapBatteryVoltagePrefail | Battery is predicted to fail | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2060 | Nodesc2TrapCorrectableMemErrorAddr | A correctable memory error at specified address was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2061 | Nodesc2TrapUncorrectableMemErrorAddr | An uncorrectable memory error at specified address was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2062 | Nodesc2TrapCorrectableMemErrorBank | A correctable memory error at specified bank was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2063 | Nodesc2TrapUncorrectableMemErrorBank | An uncorrectable memory error at specified bank was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2064 | Nodesc2TrapCorrectableMemErrorModule | A correctable memory error at specified module was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2065 | Nodesc2TrapUncorrectableMemErrorModule | An uncorrectable memory error at specified module was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2066 | Nodesc2TrapCorrectableMemError | A correctable memory error at unknown location was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2067 | Nodesc2TrapUncorrectableMemError | An uncorrectable memory error at unknown location was detected. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2068 | Nodesc2TrapMemErrorModulePrefail | A memory module is predicted to fail (prefailure). | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2069 | Nodesc2TrapMemErrorModuleFailing | A memory module is failing. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2070 | Nodesc2TrapMemErrorModuleReplaced | A memory module had failed and was replaced by a hot-spare module. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2071 | Nodesc2TrapMemErrorLoggingDisabled | Too many correctable memory errors; logging disabled. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2072 | Nodesc2TrapMemErrorLoggingEnabled | Memory errors logging enabled again. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2073 | Nodesc2TrapMemErrorAnyModuleReplaced | A memory module had failed and was replaced by a hot-spare module. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2074 | Nodesc2TrapMemErrorRedundancyLost | A memory error caused loss of memory redundancy | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2075 | Nodesc2TrapMemNVDIMMLifetime | An NVDIMM memory module has reached a certain level of lifetime | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2080 | Nodesc2TrapCpuSpeedChanged | This trap will be sent if the CPU clock frequency was changed because of a temperature problem. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2081 | Nodesc2TrapCpuPrefail | A CPU is predicted to fail (prefailure). | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2082 | Nodesc2TrapCpuIerr | A CPU internal error (IERR) occurred | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2083 | Nodesc2TrapCpuDisabled | A CPU is disabled by BIOS | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2090 | Nodesc2TrapCabinetSwitchedOff | This trap will be sent when a cabinet is switched off. For obvious reasons it cannot be sent when the main cabinet is switched off. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2091 | Nodesc2TrapCabinetSwitchedOn | This trap will be sent when a cabinet is switched on. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2092 | Nodesc2TrapPowerOffTimeReached | This trap is sent when the server is going to be switched off by schedule in some minutes. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2093 | Nodesc2TrapServerShutdown | This trap will be sent when a server is being shut down. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2094 | Nodesc2TrapShutdownCancelled | This trap will be sent if a pending server shutdown was cancelled by the user. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2095 | Nodesc2TrapBootRetryCountZero | This trap will be sent when a boot retry counter gets zero on power up. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2096 | Nodesc2TrapServerBoot | This trap will be sent when the server was booted | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2097 | Nodesc2TrapServerStandby | This trap will be sent when the server entered standby mode | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2098 | Nodesc2TrapServerSuspend | This trap will be sent when the server entered suspend mode | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2099 | Nodesc2TrapServerResumed | This trap will be sent when the server resumed from standby or suspend mode | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2100 | Nodesc2TrapMessageLogFull | The System Event Log (message log) is full. No more messages can be logged. This trap will not occur on wrap-around log types | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2101 | Nodesc2TrapMessageLogWarning | The warning threshold for the number of System Event Log entries has been exceeded. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2102 | Nodesc2TrapBootMessageLogEntry | An error message was written into the systemboard's message log. This could have happened when an error occured before the server management agents were runnin… | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2110 | Nodesc2TrapIntrusionAssertion | The front door or housing was opened | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2111 | Nodesc2TrapIntrusionDeassertion | The front door or housing was closed | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2112 | Nodesc2TrapIntrusionChanged | The front door or housing was opened or closed | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2113 | Nodesc2TrapPciBusError | PCI bus system/parity error | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2114 | Nodesc2TrapPowerOnTimeReached | This trap is sent when the server is going to be switched on by schedule in some minutes. It will be sent by the Remote Management Controller. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2120 | Nodesc2TrapCssWarning | Customer self service component changed to warning status | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2121 | Nodesc2TrapCssFail | Customer self service component changed to fail status | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2122 | Nodesc2TrapCssWarningServer | Customer self service component changed to warning status | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2123 | Nodesc2TrapCssFailServer | Customer self service component changed to fail status | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2130 | Nodesc2TrapPowerLimitOk | Power consumption limit changed to Ok status | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2131 | Nodesc2TrapPowerLimitWarning | Power consumption limit changed to warning status | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2132 | Nodesc2TrapPowerLimitCritical | Power consumption limit changed to critical status | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2133 | Nodesc2TrapPowerLimitDisabled | Power consumption limiting disabled | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2140 | Nodesc2TrapViomInitiateCommunication | VIOM communication initiation request - VIOM manager action required. This trap is intended to signal the Virtual IO Manager that the iRMC wants to confirm the… | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2141 | Nodesc2TrapViomStatusChanged | VIOM status has changed - VIOM manager information. If the user or a server management component deactivates VIOM, the iRMC will send a VIOM status trap. This … | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2150 | Nodesc2TrapDrvMonEventMessage | Driver Monitoring detected an informational event. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2151 | Nodesc2TrapDrvMonEventWarning | Driver Monitoring detected a warning event. | ||
| 1.3.6.1.4.1.231.2.10.2.2.10.20.2152 | Nodesc2TrapDrvMonEventError | Driver Monitoring detected an error event. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| CompStatus | INTEGER { ok(1), warning(2), error(3), unknown(5), notPresent(6), notManageable(7) } | ||
| LogSeverity | INTEGER { informational(1), minor(2), major(3), critical(4) } | ||
| OsLogSeverity | INTEGER { ok(1), warning(2), error(3) } | ||
| PhysAddress | OCTET STRING | ||
| TrueFalse | INTEGER { false(1), true(2) } | ||
| TrueFalseUnknown | INTEGER { unknown(1), false(2), true(3) } | ||
| UnitClass | INTEGER { unknown(1), standardServer(2), storageExtension(3), bladeServerChassis(4), bladeServer(5), clusterNode(6), multiNodeChassis(7), multiNodeServer(8), virtualServer(9), virtualPartition(10), systemboardInPartition(11), virtualServerVmware(20), virtualServerHyperV(21), virtualServerXen(22), virtualServerPan(23) } |