MIB Viewer

FUSIONIO-IODIMM-MIB

168 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.30018Nodefusionio
1.3.6.1.4.1.30018.1NodefusionIoDimm
1.3.6.1.4.1.30018.1.1NodefusionIoDimmMib
1.3.6.1.4.1.30018.1.1.1ScalarfusionIoDimmMibRevMajorread-onlymandatoryMajor MIB revision. This will increment when incompatible structural changes occur.
1.3.6.1.4.1.30018.1.1.2ScalarfusionIoDimmMibRevMinorread-onlymandatoryMinor MIB revision. This will increment when minor additions occur.
1.3.6.1.4.1.30018.1.1.3ScalarfusionIoDimmMIBConditionread-onlymandatoryThe overall MIB condition.
1.3.6.1.4.1.30018.1.2NodefusionIoDimmComponent
1.3.6.1.4.1.30018.1.2.1NodefusionIoDimmInfo
1.3.6.1.4.1.30018.1.2.1.1TablefusionIoDimmInfoTablenot-accessiblemandatoryThere will be an entry in this table for each ioDrive device installed.
1.3.6.1.4.1.30018.1.2.1.1.1RowfusionIoDimmInfoEntrynot-accessiblemandatoryEach entry represents an ioDrive device.
1.3.6.1.4.1.30018.1.2.1.1.1.1ColumnfusionIoDimmInfoIndexread-onlymandatoryUnique index for ioDrive entries.
1.3.6.1.4.1.30018.1.2.1.1.1.2ColumnfusionIoDimmInfoStatusread-onlymandatoryThe overall status of the ioDrive device.
1.3.6.1.4.1.30018.1.2.1.1.1.3ColumnfusionIoDimmInfoNameread-writemandatorySystem control device name for this device.
1.3.6.1.4.1.30018.1.2.1.1.1.4ColumnfusionIoDimmInfoSerialNumberread-onlymandatorySerial number of this device.
1.3.6.1.4.1.30018.1.2.1.1.1.5ColumnfusionIoDimmInfoPartNumberread-onlymandatorySystem part number of this device.
1.3.6.1.4.1.30018.1.2.1.1.1.6ColumnfusionIoDimmInfoSubVendorPartNumberread-onlymandatorySub-vendor system part number of this device.
1.3.6.1.4.1.30018.1.2.1.1.1.7ColumnfusionIoDimmInfoSparePartNumberread-onlymandatoryThe spare part number of this device.
1.3.6.1.4.1.30018.1.2.1.1.1.8ColumnfusionIoDimmInfoAssemblyNumberread-onlymandatoryThe assembly number of this device (HW revision).
1.3.6.1.4.1.30018.1.2.1.1.1.9ColumnfusionIoDimmInfoFirmwareVersionread-onlymandatoryFirmware version of this device.
1.3.6.1.4.1.30018.1.2.1.1.1.10ColumnfusionIoDimmInfoDriverVersionread-onlymandatoryDevice driver version.
1.3.6.1.4.1.30018.1.2.1.1.1.11ColumnfusionIoDimmInfoUIDread-onlymandatoryDevice UID written at format time.
1.3.6.1.4.1.30018.1.2.1.1.1.12ColumnfusionIoDimmInfoStateread-writemandatoryThe current state of the attached client device. In order to function normally, the device must be in the 'attached' state. Quiescent states: attached = device…
1.3.6.1.4.1.30018.1.2.1.1.1.13ColumnfusionIoDimmInfoClientDeviceNameread-onlymandatoryThe name of the attached client device.
1.3.6.1.4.1.30018.1.2.1.1.1.14ColumnfusionIoDimmInfoBeaconread-writemandatoryWriting a true value here will turn on the LED flashing beacon for visual card identification. A false value will turn the LED beacon off.
1.3.6.1.4.1.30018.1.2.1.1.1.15ColumnfusionIoDimmInfoPCIAddressread-onlymandatoryDevice address on the PCI bus.
1.3.6.1.4.1.30018.1.2.1.1.1.16ColumnfusionIoDimmInfoPCIDeviceIDread-onlymandatoryDevice PCI ID.
1.3.6.1.4.1.30018.1.2.1.1.1.17ColumnfusionIoDimmInfoPCISubdeviceIDread-onlymandatoryDevice PCI subdevice ID.
1.3.6.1.4.1.30018.1.2.1.1.1.18ColumnfusionIoDimmInfoPCIVendorIDread-onlymandatoryDevice PCI vendor ID.
1.3.6.1.4.1.30018.1.2.1.1.1.19ColumnfusionIoDimmInfoPCISubvendorIDread-onlymandatoryDevice PCI subvendor ID.
1.3.6.1.4.1.30018.1.2.1.1.1.20ColumnfusionIoDimmInfoPCISlotread-onlymandatoryDevice PCI slot number.
1.3.6.1.4.1.30018.1.2.1.1.1.21ColumnfusionIoDimmInfoWearoutIndicatorread-onlymandatoryA true condition indicates that the device has surpassed the wearout threshold.
1.3.6.1.4.1.30018.1.2.1.1.1.22ColumnfusionIoDimmInfoFlashbackIndicatorread-onlyobsoleteA true condition indicates that flashback redundancy is degraded.
1.3.6.1.4.1.30018.1.2.1.1.1.23ColumnfusionIoDimmInfoWritableIndicatorread-onlymandatoryA value that indicates the writability of the device.
1.3.6.1.4.1.30018.1.2.1.1.1.24ColumnfusionIoDimmInfoInternalTempread-onlymandatoryThe current internal temperature of the device in Celsius.
1.3.6.1.4.1.30018.1.2.1.1.1.25ColumnfusionIoDimmInfoHealthPercentageread-onlymandatoryAn estimate of the health of the drive expressed as the remaining percentage of drive life before write rate is reduced due to wearout. If health percentage is…
1.3.6.1.4.1.30018.1.2.1.1.1.26ColumnfusionIoDimmInfoShortTermWearoutDateread-onlyobsoleteThe date that the drive is estimated to reach the wearout threshold based on drive usage in the short-term interval.
1.3.6.1.4.1.30018.1.2.1.1.1.27ColumnfusionIoDimmInfoLongTermWearoutDateread-onlyobsoleteThe date that the drive is estimated to reach the wearout threshold based on drive usage in the long-term interval.
1.3.6.1.4.1.30018.1.2.1.1.1.28ColumnfusionIoDimmInfoShortTermNonWritableDateread-onlyobsoleteThe date that the drive is estimated to go non-writable based on drive usage in the short-term interval.
1.3.6.1.4.1.30018.1.2.1.1.1.29ColumnfusionIoDimmInfoLongTermNonWritableDateread-onlyobsoleteThe date that the drive is estimated to go non-writable based on drive usage in the long-term interval.
1.3.6.1.4.1.30018.1.2.1.1.1.30ColumnfusionIoDimmInfoMinimalModeReasonread-onlymandatoryReason card is in minimal mode.
1.3.6.1.4.1.30018.1.2.1.1.1.31ColumnfusionIoDimmInfoReducedWriteReasonread-onlymandatoryReason card is in reduced write mode.
1.3.6.1.4.1.30018.1.2.1.1.1.32ColumnfusionIoDimmInfoMilliVoltsread-onlymandatoryCurrent voltage level of PCIe 12 volt bus in millivolts. A value of 0 means value could not be determined.
1.3.6.1.4.1.30018.1.2.1.1.1.33ColumnfusionIoDimmInfoMilliVoltsPeakread-onlymandatoryPeak voltage level of PCIe 12 volt bus in millivolts. A value of 0 means value could not be determined.
1.3.6.1.4.1.30018.1.2.1.1.1.34ColumnfusionIoDimmInfoMilliVoltsMinread-onlymandatoryMinimum voltage level of PCIe 12 volt bus in millivolts. A value of 0 means value could not be determined.
1.3.6.1.4.1.30018.1.2.1.1.1.35ColumnfusionIoDimmInfoMilliWattsread-onlymandatoryCurrent wattage drawn on the PCIe 12 volt bus in milliwatts. A value of 0 means value could not be determined.
1.3.6.1.4.1.30018.1.2.1.1.1.36ColumnfusionIoDimmInfoMilliWattsPeakread-onlymandatoryPeak wattage drawn on the PCIe 12 volt bus in milliwatts. A value of 0 means value could not be determined.
1.3.6.1.4.1.30018.1.2.1.1.1.37ColumnfusionIoDimmInfoMilliAmpsread-onlymandatoryAmperage flowing on the PCIe 12 volt bus in milliamps. A value of 0 means value could not be determined.
1.3.6.1.4.1.30018.1.2.1.1.1.38ColumnfusionIoDimmInfoMilliAmpsPeakread-onlymandatoryPeak amperage flowing on the PCIe 12 volt bus in milliamps. A value of 0 means value could not be determined.
1.3.6.1.4.1.30018.1.2.1.1.1.39ColumnfusionIoDimmInfoAdapterTyperead-onlymandatoryType of ioDimm adapter.
1.3.6.1.4.1.30018.1.2.1.1.1.40ColumnfusionIoDimmInfoAdapterPortread-onlymandatoryPort number of this ioDimm on the adapter. If port number is not available the value will be set to -1.
1.3.6.1.4.1.30018.1.2.1.1.1.41ColumnfusionIoDimmInfoAdapterSerialNumberread-onlymandatorySerial number of the adapter where this ioDimm is connected.
1.3.6.1.4.1.30018.1.2.1.1.1.42ColumnfusionIoDimmInfoAdapterExtPowerPresentread-onlymandatoryA true condition indicates that external power is connected on the adapter where this ioDimm is connected.
1.3.6.1.4.1.30018.1.2.1.1.1.43ColumnfusionIoDimmInfoPowerlossProtectDisabledread-onlymandatoryA true condition indicates that powerloss protection is available but disabled.
1.3.6.1.4.1.30018.1.2.1.1.1.44ColumnfusionIoDimmInfoInternalTempHighread-onlymandatoryA true condition indicates that the internal temperature is nearing the maximum rating.
1.3.6.1.4.1.30018.1.2.1.1.1.45ColumnfusionIoDimmInfoAmbientTempread-onlyobsoleteThe current ambient temperature of the device in Celsius.
1.3.6.1.4.1.30018.1.2.1.1.1.46ColumnfusionIoDimmInfoPCIBandwidthCompatibilityread-onlymandatoryThe bandwidth compatibility of the PCI-E slot. If the value is not optimal, the status and condition variables will be set accordingly.
1.3.6.1.4.1.30018.1.2.1.1.1.47ColumnfusionIoDimmInfoPCIPowerCompatibilityread-onlymandatoryThe power compatibility of the PCI-E slot. If the value is not optimal, the status and condition variables will be set accordingly.
1.3.6.1.4.1.30018.1.2.1.1.1.48ColumnfusionIoDimmInfoActualGoverningLevelread-onlymandatoryThe level of governing currently happening on the device. This may be due to any of several reasons. Current reasons are because of high temperature, power sho…
1.3.6.1.4.1.30018.1.2.1.1.1.49ColumnfusionIoDimmInfoLifespanGoverningLevelread-onlyobsoleteGoverning may be impacted for the sake of prolonging longevity of the device. This value indicates the level of contribution for longevity. none = no governing…
1.3.6.1.4.1.30018.1.2.1.1.1.50ColumnfusionIoDimmInfoPowerGoverningLevelread-onlymandatoryGoverning may be impacted due to a lack of power available to the device. This value indicates the level of contribution due to lack of power. none = no govern…
1.3.6.1.4.1.30018.1.2.1.1.1.51ColumnfusionIoDimmInfoThermalGoverningLevelread-onlymandatoryGoverning may be impacted due to the device reaching high temperatures. This value indicates the level of contribution due to high temperatures. none = no gove…
1.3.6.1.4.1.30018.1.2.1.1.1.52ColumnfusionIoDimmInfoLifespanGoverningEnabledread-onlyobsoleteA true condition indicates that lifespan governing is enabled.
1.3.6.1.4.1.30018.1.2.1.1.1.53ColumnfusionIoDimmInfoLifespanGoverningTgtDateread-onlyobsoleteThe target lifespan governing date.
1.3.6.1.4.1.30018.1.2.1.1.1.54ColumnfusionIoDimmInfoInternalTempCriticalread-onlymandatoryA true condition indicates that temperature is at a critical level.
1.3.6.1.4.1.30018.1.2.1.1.1.55ColumnfusionIoDimmInfoInternalTempShutdownread-onlymandatoryA true condition indicates that temperature is has surpassed a critical level and the device will shut down.
1.3.6.1.4.1.30018.1.2.1.1.1.56ColumnfusionIoDimmInfoPcieErrorsIndicatorread-onlymandatoryIndicates whether correctable or uncorrectable PCIe errors have been detected on the PCIe bus.
1.3.6.1.4.1.30018.1.2.1.1.1.57ColumnfusionIoDimmInfoMissingLebMapIndicatorread-onlymandatoryA true condition indicates the device is missing a LEB map and cannot be attached.
1.3.6.1.4.1.30018.1.2.1.1.1.58ColumnfusionIoDimmInfoVccIntErrorIndicatorread-onlymandatoryA true condition indicates the device is experiencing a VccInt out of range error.
1.3.6.1.4.1.30018.1.2.1.1.1.59ColumnfusionIoDimmInfoVccAuxErrorIndicatorread-onlymandatoryA true condition indicates the device is experiencing a VccAux out of range error.
1.3.6.1.4.1.30018.1.2.1.1.1.60ColumnfusionIoDimmInfoOverPowerIndicatorread-onlymandatoryA true condition indicates the device is experiencing an overpower error. Plug in external power to solve the problem.
1.3.6.1.4.1.30018.1.2.1.1.1.61ColumnfusionIoDimmInfoUpgradeInProgressIndicatorread-onlymandatoryA true condition indicates the device is currently in the process of being upgraded to a new major revision of the VSL driver.
1.3.6.1.4.1.30018.1.2.1.1.1.62ColumnfusionIoDimmInfoInternalTempHighThresholdread-onlymandatoryThreshold at which temperature will be considered high (warning level) and temperature high trap will be fired.
1.3.6.1.4.1.30018.1.2.1.1.1.63ColumnfusionIoDimmInfoInternalTempCriticalThresholdread-onlymandatoryThreshold at which temperature will be at a critical level and a critical temperature trap will be fired.
1.3.6.1.4.1.30018.1.2.1.1.1.64ColumnfusionIoDimmInfoInternalTempShutdownThresholdread-onlymandatoryThreshold at which temperature will be at a shutdown level and a critical temperature trap will be fired.
1.3.6.1.4.1.30018.1.2.1.1.1.65ColumnfusionIoDimmInfoVirtualControllerNumberread-onlymandatoryThe number of this virtual controller on the physical ioMemory device.
1.3.6.1.4.1.30018.1.2.1.1.1.66ColumnfusionIoDimmInfoVirtualControllerCountread-onlymandatoryThe total number of active virtual controllers on the physical ioMemory device.
1.3.6.1.4.1.30018.1.2.1.1.1.67ColumnfusionIoDimmInfoActiveMediaPercentread-onlymandatoryThe total active media on the device as a percent.
1.3.6.1.4.1.30018.1.2.2NodefusionIoDimmExtn
1.3.6.1.4.1.30018.1.2.2.1TablefusionIoDimmExtnTablenot-accessiblemandatoryFusion-io ioDrive extension table.
1.3.6.1.4.1.30018.1.2.2.1.1RowfusionIoDimmExtnEntrynot-accessiblemandatoryRepresents an entry in the fusionIoDimmExtnTable.
1.3.6.1.4.1.30018.1.2.2.1.1.1ColumnfusionIoDimmExtnIndexread-onlymandatoryThe unique index for the ioDrive extension table. There should be an entry in this table for each entry in the ioDrive table.
1.3.6.1.4.1.30018.1.2.2.1.1.2ColumnfusionIoDimmExtnTotalPhysCapacityUread-onlymandatoryThe upper word of the max format size in bytes.
1.3.6.1.4.1.30018.1.2.2.1.1.3ColumnfusionIoDimmExtnTotalPhysCapacityLread-onlymandatoryThe lower word of the max format size in bytes.
1.3.6.1.4.1.30018.1.2.2.1.1.4ColumnfusionIoDimmExtnUsablePhysCapacityUread-onlyobsoleteThe upper word of the usable physical capacity in bytes. This is space that is holding valid data, is erased and ready for writing or waiting to be reclaimed v…
1.3.6.1.4.1.30018.1.2.2.1.1.5ColumnfusionIoDimmExtnUsablePhysCapacityLread-onlyobsoleteThe lower word of the usable physical capacity in bytes. This is space that is holding valid data, is erased and ready for writing or waiting to be reclaimed v…
1.3.6.1.4.1.30018.1.2.2.1.1.6ColumnfusionIoDimmExtnUsedPhysCapacityUread-onlyobsoleteThe upper word used physical capacity in bytes. This is the space holding valid, current data.
1.3.6.1.4.1.30018.1.2.2.1.1.7ColumnfusionIoDimmExtnUsedPhysCapacityLread-onlyobsoleteThe lower word used physical capacity in bytes. This is the space holding valid, current data.
1.3.6.1.4.1.30018.1.2.2.1.1.8ColumnfusionIoDimmExtnTotalLogCapacityUread-onlymandatoryThe upper word of the total logical capacity in bytes as formatted.
1.3.6.1.4.1.30018.1.2.2.1.1.9ColumnfusionIoDimmExtnTotalLogCapacityLread-onlymandatoryThe lower word of the total logical capacity in bytes as formatted.
1.3.6.1.4.1.30018.1.2.2.1.1.10ColumnfusionIoDimmExtnAvailLogCapacityUread-onlyobsoleteThe upper word of the available logical capacity in bytes.
1.3.6.1.4.1.30018.1.2.2.1.1.11ColumnfusionIoDimmExtnAvailLogCapacityLread-onlyobsoleteThe lower word of the available logical capacity in bytes.
1.3.6.1.4.1.30018.1.2.2.1.1.12ColumnfusionIoDimmExtnBytesReadUread-onlymandatoryThe upper word of the total number of bytes read since the device was formatted.
1.3.6.1.4.1.30018.1.2.2.1.1.13ColumnfusionIoDimmExtnBytesReadLread-onlymandatoryThe lower word of the total number of bytes read since the device was formatted.
1.3.6.1.4.1.30018.1.2.2.1.1.14ColumnfusionIoDimmExtnBytesWrittenUread-onlymandatoryThe upper word of the total bytes written.
1.3.6.1.4.1.30018.1.2.2.1.1.15ColumnfusionIoDimmExtnBytesWrittenLread-onlymandatoryThe lower word of the total bytes written.
1.3.6.1.4.1.30018.1.2.2.1.1.16ColumnfusionIoDimmExtnLogBytesWrittenUread-onlyobsoleteThe upper word of the number of user data bytes written.
1.3.6.1.4.1.30018.1.2.2.1.1.17ColumnfusionIoDimmExtnLogBytesWrittenLread-onlyobsoleteThe lower word of the number of user data bytes written.
1.3.6.1.4.1.30018.1.2.2.1.1.18ColumnfusionIoDimmExtnShortTermStartDateread-writeobsoleteThe start date used to characterize short-term drive usage.
1.3.6.1.4.1.30018.1.2.2.1.1.19ColumnfusionIoDimmExtnShortTermWindowread-writeobsoleteThe number of hours in the short-term usage characterization window. If this value is non-zero, then the short-term start date will automatically track with th…
1.3.6.1.4.1.30018.1.2.2.1.1.20ColumnfusionIoDimmExtnShortTermEndDateread-writeobsoleteThe end date used to characterize short-term drive usage.
1.3.6.1.4.1.30018.1.2.2.1.1.21ColumnfusionIoDimmExtnShortTermEndDateFloatread-writeobsoleteSet this variable true to automatically have the short-term end date automatically updated to the present date.
1.3.6.1.4.1.30018.1.2.2.1.1.22ColumnfusionIoDimmExtnLongTermStartDateread-writeobsoleteThe start date used to characterize long-term drive usage.
1.3.6.1.4.1.30018.1.2.2.1.1.23ColumnfusionIoDimmExtnLongTermWindowread-writeobsoleteThe number of hours in the long-term usage characterization window. If this value is non-zero, then the long-term start date will automatically track with the …
1.3.6.1.4.1.30018.1.2.2.1.1.24ColumnfusionIoDimmExtnLongTermEndDateread-writeobsoleteThe end date used to characterize long-term drive usage.
1.3.6.1.4.1.30018.1.2.2.1.1.25ColumnfusionIoDimmExtnLongTermEndDateFloatread-writeobsoleteSet this variable true to automatically have the long-term end date automatically updated to the present date.
1.3.6.1.4.1.30018.1.2.2.1.1.26ColumnfusionIoDimmExtnWriteRateAutoCalcread-writeobsoleteSet this true to automatically calculate the long-term and short-term average write rate based on the start and end dates selected. Otherwise, the average writ…
1.3.6.1.4.1.30018.1.2.2.1.1.27ColumnfusionIoDimmExtnShortTermAvgUread-writeobsoleteThe upper word of the short-term average write rate used to characterize drive usage. This will be automatically calculated based on short-term start and end d…
1.3.6.1.4.1.30018.1.2.2.1.1.28ColumnfusionIoDimmExtnShortTermAvgLread-writeobsoleteThe lower word of the short-term average write rate used to characterize drive usage. This will be automatically calculated based on short-term start and end d…
1.3.6.1.4.1.30018.1.2.2.1.1.29ColumnfusionIoDimmExtnLongTermAvgUread-writeobsoleteThe upper word of the long-term average write rate used to characterize drive usage. This will be automatically calculated based on long-term start and end dat…
1.3.6.1.4.1.30018.1.2.2.1.1.30ColumnfusionIoDimmExtnLongTermAvgLread-writeobsoleteThe lower word of the long-term average write rate used to characterize drive usage. This will be automatically calculated based on long-term start and end dat…
1.3.6.1.4.1.30018.1.2.2.1.1.31ColumnfusionIoDimmExtnConfidenceIntervalread-writeobsoleteThis defines the confidence interval used to calculate the wearout and non-writable dates. Expressed as a percentage, this value reflects the confidence in the…
1.3.6.1.4.1.30018.1.2.2.1.1.32ColumnfusionIoDimmExtnFormattedBlockSizeread-onlymandatoryThe block size that this device is formatted to use.
1.3.6.1.4.1.30018.1.2.2.1.1.33ColumnfusionIoDimmExtnCurrentRAMUsageUread-onlymandatoryThe upper word of the current RAM usage in bytes for the drive.
1.3.6.1.4.1.30018.1.2.2.1.1.34ColumnfusionIoDimmExtnCurrentRAMUsageLread-onlymandatoryThe lower word of the current RAM usage in bytes for the drive.
1.3.6.1.4.1.30018.1.2.2.1.1.35ColumnfusionIoDimmExtnPeakRAMUsageUread-onlymandatoryThe upper word of the peak RAM usage in bytes for the drive.
1.3.6.1.4.1.30018.1.2.2.1.1.36ColumnfusionIoDimmExtnPeakRAMUsageLread-onlymandatoryThe lower word of the peak RAM usage in bytes for the drive.
1.3.6.1.4.1.30018.1.2.3NodefusionIoDimmCapacity
1.3.6.1.4.1.30018.1.2.3.1TablefusionIoDimmCapacityTablenot-accessibleoptionalA table of usable physical capacity values over time.
1.3.6.1.4.1.30018.1.2.3.1.1RowfusionIoDimmCapacityEntrynot-accessibleoptionalDefines an entry of the usable physical capacity history table.
1.3.6.1.4.1.30018.1.2.3.1.1.1ColumnfusionIoDimmCapacityInfoIndexread-onlyoptionalThe ioDrive index. This correlates to the drive index in the info table.
1.3.6.1.4.1.30018.1.2.3.1.1.2ColumnfusionIoDimmCapacityIndexread-onlyoptionalUnique index for the usable physical capacity log.
1.3.6.1.4.1.30018.1.2.3.1.1.3ColumnfusionIoDimmCapacityValueUread-onlyoptionalThe upper word of the physical usable capacity at this point in time.
1.3.6.1.4.1.30018.1.2.3.1.1.4ColumnfusionIoDimmCapacityValueLread-onlyoptionalThe lower word of the physical usable capacity at this point in time.
1.3.6.1.4.1.30018.1.2.3.1.1.5ColumnfusionIoDimmCapacityTimestampread-onlyoptionalThe time stamp of this value entry.
1.3.6.1.4.1.30018.1.2.4NodefusionIoDimmWrite
1.3.6.1.4.1.30018.1.2.4.1TablefusionIoDimmWriteTablenot-accessibleoptionalA log of write volume history.
1.3.6.1.4.1.30018.1.2.4.1.1RowfusionIoDimmWriteEntrynot-accessibleoptionalAn entry in the write volume history table.
1.3.6.1.4.1.30018.1.2.4.1.1.1ColumnfusionIoDimmWriteInfoIndexread-onlyoptionalThe ioDrive index. This correlates with the index in the info table.
1.3.6.1.4.1.30018.1.2.4.1.1.2ColumnfusionIoDimmWriteIndexread-onlyoptionalUnique index for this write volume entry.
1.3.6.1.4.1.30018.1.2.4.1.1.3ColumnfusionIoDimmWriteValueUread-onlyoptionalThe upper word of the total physical number of bytes written at a given moment in time.
1.3.6.1.4.1.30018.1.2.4.1.1.4ColumnfusionIoDimmWriteValueLread-onlyoptionalThe lower word of the total physical number of bytes written at a given moment in time.
1.3.6.1.4.1.30018.1.2.4.1.1.5ColumnfusionIoDimmWriteTimestampread-onlyoptionalThe timestamp entry for this value.
1.3.6.1.4.1.30018.1.2.5NodefusionIoDimmTemp
1.3.6.1.4.1.30018.1.2.5.1TablefusionIoDimmTempTablenot-accessibleoptionalDevice temperature history table.
1.3.6.1.4.1.30018.1.2.5.1.1RowfusionIoDimmTempEntrynot-accessibleoptionalDevice temperature history entry.
1.3.6.1.4.1.30018.1.2.5.1.1.1ColumnfusionIoDimmTempInfoIndexread-onlyoptionalThe device index. This correlates to the index in the info table.
1.3.6.1.4.1.30018.1.2.5.1.1.2ColumnfusionIoDimmTempIndexread-onlyoptionalUnique index for this temperature log entry.
1.3.6.1.4.1.30018.1.2.5.1.1.3ColumnfusionIoDimmTempValueread-onlyoptionalThe current temperature of the device in Celsius..
1.3.6.1.4.1.30018.1.2.5.1.1.4ColumnfusionIoDimmTempTimestampread-onlyoptionalThe timestamp for this entry.
1.3.6.1.4.1.30018.1.2.6NodefusionIoDimmProc
1.3.6.1.4.1.30018.1.2.6.1TablefusionIoDimmProcTablenot-accessibleobsoleteA table of processes that support device operation.
1.3.6.1.4.1.30018.1.2.6.1.1RowfusionIoDimmProcEntrynot-accessibleobsoleteEach entry represents a process.
1.3.6.1.4.1.30018.1.2.6.1.1.1ColumnfusionIoDimmProcIndexread-onlyobsoleteA unique index for each process.
1.3.6.1.4.1.30018.1.2.6.1.1.2ColumnfusionIoDimmProcNameread-onlyobsoleteThe process name.
1.3.6.1.4.1.30018.1.2.6.1.1.3ColumnfusionIoDimmProcStateread-onlyobsoleteThe process state.
1.3.6.1.4.1.30018.1.2.6.1.1.4ColumnfusionIoDimmProcRAMread-onlyobsoleteThe bytes of RAM currently in use by the process.
1.3.6.1.4.1.30018.1.2.6.1.1.5ColumnfusionIoDimmProcCPUread-onlyobsoleteThe overall percentage of CPU usage.
1.3.6.1.4.1.30018.25ScalarfusionIoDimmTrapFlagsread-onlyobsoleteThis is a collection of flags used only during trap delivery. Each bit has the following meaning: Bit 5-31: Reserved (always 0) Bit 2-4: Trap Condition 0 = Not…
1.3.6.1.4.1.30018.1001NodefusionIoDimmWearoutTrapGenerated when the device begins to wear out.
1.3.6.1.4.1.30018.1002NodefusionIoDimmNonWritableTrapGenerated when the device is in write-reduced or non-writable mode based on the fusionIoDimmInfoWritableIndicator. This can be due to excessive wear or other d…
1.3.6.1.4.1.30018.1003NodefusionIoDimmFlashbackTrapGenerated when flashback protection becomes degraded.
1.3.6.1.4.1.30018.1004NodefusionIoDimmTempHighTrapGenerated when the temperature sensor surpasses the warning threshold.
1.3.6.1.4.1.30018.1005NodefusionIoDimmTempOkTrapGenerated when temperature returns to a safe level.
1.3.6.1.4.1.30018.1006NodefusionIoDimmErrorTrapGenerated when device is in an error state.
1.3.6.1.4.1.30018.1007NodefusionIoDimmPowerlossProtectTrapGenerated when the powerloss protection feature is available but disabled.
1.3.6.1.4.1.30018.1008NodefusionIoDimmCriticalTempTrapGenerated when the temperature sensor is at a critical threshold.
1.3.6.1.4.1.30018.1009NodefusionIoDimmShutdownTempTrapGenerated when the temperature sensor surpasses the shutdown threshold.
1.3.6.1.4.1.30018.1010NodefusionIoDimmPcieErrorsTrapGenerated when PCIe bus errors are detected.
1.3.6.1.4.1.30018.1011NodefusionIoDimmMissingLebMapTrapGenerated when the ioMemory is found to be missing a LEB map.
1.3.6.1.4.1.30018.1012NodefusionIoDimmSlotBandwidthIncompatibleTrapGenerated when the ioMemory is found to be in an incompatible PCIe slot.
1.3.6.1.4.1.30018.1013NodefusionIoDimmSlotBandwidthSuboptimalTrapGenerated when the ioMemory is found to be in an sub-optimal PCIe slot.
1.3.6.1.4.1.30018.1014NodefusionIoDimmLowReservesTrapGenerated when the ioMemory is low on reserve space, but not yet depleted.
1.3.6.1.4.1.30018.1015NodefusionIoDimmVccIntTrapGenerated when the ioMemory is out of range for vccint.
1.3.6.1.4.1.30018.1016NodefusionIoDimmVccAuxTrapGenerated when the ioMemory is out of range for vccaux.
1.3.6.1.4.1.30018.1017NodefusionIoDimmMinimalModeTrapGenerated when the ioMemory is in minimal mode.
1.3.6.1.4.1.30018.1018NodefusionIoDimmOverPowerTrapGenerated when the ioMemory is using too much power. Plug in an external power cable to correct the issue.
1.3.6.1.4.1.30018.1019NodefusionIoDimmUpgradeInProgressTrapGenerated when the ioMemory is in the process of upgrading to a new major driver version.
Type Definitions
NameSyntaxStatusDescription
BooleanINTEGER { true(1), false(2) }