FUSIONIO-IODIMM-MIB
168 objects
No module-level DESCRIPTION found.
Imported Objects
| RFC-1212 | OBJECT-TYPE |
| RFC-1215 | TRAP-TYPE |
| RFC1155-SMI | Counter enterprises |
| RFC1213-MIB | DisplayString sysName |
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.30018 | Nodefusionio | |||
| 1.3.6.1.4.1.30018.1 | NodefusionIoDimm | |||
| 1.3.6.1.4.1.30018.1.1 | NodefusionIoDimmMib | |||
| 1.3.6.1.4.1.30018.1.1.1 | ScalarfusionIoDimmMibRevMajor | read-only | mandatory | Major MIB revision. This will increment when incompatible structural changes occur. |
| 1.3.6.1.4.1.30018.1.1.2 | ScalarfusionIoDimmMibRevMinor | read-only | mandatory | Minor MIB revision. This will increment when minor additions occur. |
| 1.3.6.1.4.1.30018.1.1.3 | ScalarfusionIoDimmMIBCondition | read-only | mandatory | The overall MIB condition. |
| 1.3.6.1.4.1.30018.1.2 | NodefusionIoDimmComponent | |||
| 1.3.6.1.4.1.30018.1.2.1 | NodefusionIoDimmInfo | |||
| 1.3.6.1.4.1.30018.1.2.1.1 | TablefusionIoDimmInfoTable | not-accessible | mandatory | There will be an entry in this table for each ioDrive device installed. |
| 1.3.6.1.4.1.30018.1.2.1.1.1 | RowfusionIoDimmInfoEntry | not-accessible | mandatory | Each entry represents an ioDrive device. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.1 | ColumnfusionIoDimmInfoIndex | read-only | mandatory | Unique index for ioDrive entries. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.2 | ColumnfusionIoDimmInfoStatus | read-only | mandatory | The overall status of the ioDrive device. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.3 | ColumnfusionIoDimmInfoName | read-write | mandatory | System control device name for this device. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.4 | ColumnfusionIoDimmInfoSerialNumber | read-only | mandatory | Serial number of this device. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.5 | ColumnfusionIoDimmInfoPartNumber | read-only | mandatory | System part number of this device. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.6 | ColumnfusionIoDimmInfoSubVendorPartNumber | read-only | mandatory | Sub-vendor system part number of this device. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.7 | ColumnfusionIoDimmInfoSparePartNumber | read-only | mandatory | The spare part number of this device. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.8 | ColumnfusionIoDimmInfoAssemblyNumber | read-only | mandatory | The assembly number of this device (HW revision). |
| 1.3.6.1.4.1.30018.1.2.1.1.1.9 | ColumnfusionIoDimmInfoFirmwareVersion | read-only | mandatory | Firmware version of this device. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.10 | ColumnfusionIoDimmInfoDriverVersion | read-only | mandatory | Device driver version. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.11 | ColumnfusionIoDimmInfoUID | read-only | mandatory | Device UID written at format time. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.12 | ColumnfusionIoDimmInfoState | read-write | mandatory | The current state of the attached client device. In order to function normally, the device must be in the 'attached' state. Quiescent states: attached = device… |
| 1.3.6.1.4.1.30018.1.2.1.1.1.13 | ColumnfusionIoDimmInfoClientDeviceName | read-only | mandatory | The name of the attached client device. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.14 | ColumnfusionIoDimmInfoBeacon | read-write | mandatory | Writing a true value here will turn on the LED flashing beacon for visual card identification. A false value will turn the LED beacon off. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.15 | ColumnfusionIoDimmInfoPCIAddress | read-only | mandatory | Device address on the PCI bus. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.16 | ColumnfusionIoDimmInfoPCIDeviceID | read-only | mandatory | Device PCI ID. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.17 | ColumnfusionIoDimmInfoPCISubdeviceID | read-only | mandatory | Device PCI subdevice ID. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.18 | ColumnfusionIoDimmInfoPCIVendorID | read-only | mandatory | Device PCI vendor ID. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.19 | ColumnfusionIoDimmInfoPCISubvendorID | read-only | mandatory | Device PCI subvendor ID. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.20 | ColumnfusionIoDimmInfoPCISlot | read-only | mandatory | Device PCI slot number. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.21 | ColumnfusionIoDimmInfoWearoutIndicator | read-only | mandatory | A true condition indicates that the device has surpassed the wearout threshold. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.22 | ColumnfusionIoDimmInfoFlashbackIndicator | read-only | obsolete | A true condition indicates that flashback redundancy is degraded. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.23 | ColumnfusionIoDimmInfoWritableIndicator | read-only | mandatory | A value that indicates the writability of the device. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.24 | ColumnfusionIoDimmInfoInternalTemp | read-only | mandatory | The current internal temperature of the device in Celsius. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.25 | ColumnfusionIoDimmInfoHealthPercentage | read-only | mandatory | An estimate of the health of the drive expressed as the remaining percentage of drive life before write rate is reduced due to wearout. If health percentage is… |
| 1.3.6.1.4.1.30018.1.2.1.1.1.26 | ColumnfusionIoDimmInfoShortTermWearoutDate | read-only | obsolete | The date that the drive is estimated to reach the wearout threshold based on drive usage in the short-term interval. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.27 | ColumnfusionIoDimmInfoLongTermWearoutDate | read-only | obsolete | The date that the drive is estimated to reach the wearout threshold based on drive usage in the long-term interval. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.28 | ColumnfusionIoDimmInfoShortTermNonWritableDate | read-only | obsolete | The date that the drive is estimated to go non-writable based on drive usage in the short-term interval. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.29 | ColumnfusionIoDimmInfoLongTermNonWritableDate | read-only | obsolete | The date that the drive is estimated to go non-writable based on drive usage in the long-term interval. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.30 | ColumnfusionIoDimmInfoMinimalModeReason | read-only | mandatory | Reason card is in minimal mode. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.31 | ColumnfusionIoDimmInfoReducedWriteReason | read-only | mandatory | Reason card is in reduced write mode. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.32 | ColumnfusionIoDimmInfoMilliVolts | read-only | mandatory | Current voltage level of PCIe 12 volt bus in millivolts. A value of 0 means value could not be determined. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.33 | ColumnfusionIoDimmInfoMilliVoltsPeak | read-only | mandatory | Peak voltage level of PCIe 12 volt bus in millivolts. A value of 0 means value could not be determined. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.34 | ColumnfusionIoDimmInfoMilliVoltsMin | read-only | mandatory | Minimum voltage level of PCIe 12 volt bus in millivolts. A value of 0 means value could not be determined. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.35 | ColumnfusionIoDimmInfoMilliWatts | read-only | mandatory | Current wattage drawn on the PCIe 12 volt bus in milliwatts. A value of 0 means value could not be determined. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.36 | ColumnfusionIoDimmInfoMilliWattsPeak | read-only | mandatory | Peak wattage drawn on the PCIe 12 volt bus in milliwatts. A value of 0 means value could not be determined. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.37 | ColumnfusionIoDimmInfoMilliAmps | read-only | mandatory | Amperage flowing on the PCIe 12 volt bus in milliamps. A value of 0 means value could not be determined. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.38 | ColumnfusionIoDimmInfoMilliAmpsPeak | read-only | mandatory | Peak amperage flowing on the PCIe 12 volt bus in milliamps. A value of 0 means value could not be determined. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.39 | ColumnfusionIoDimmInfoAdapterType | read-only | mandatory | Type of ioDimm adapter. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.40 | ColumnfusionIoDimmInfoAdapterPort | read-only | mandatory | Port number of this ioDimm on the adapter. If port number is not available the value will be set to -1. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.41 | ColumnfusionIoDimmInfoAdapterSerialNumber | read-only | mandatory | Serial number of the adapter where this ioDimm is connected. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.42 | ColumnfusionIoDimmInfoAdapterExtPowerPresent | read-only | mandatory | A true condition indicates that external power is connected on the adapter where this ioDimm is connected. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.43 | ColumnfusionIoDimmInfoPowerlossProtectDisabled | read-only | mandatory | A true condition indicates that powerloss protection is available but disabled. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.44 | ColumnfusionIoDimmInfoInternalTempHigh | read-only | mandatory | A true condition indicates that the internal temperature is nearing the maximum rating. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.45 | ColumnfusionIoDimmInfoAmbientTemp | read-only | obsolete | The current ambient temperature of the device in Celsius. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.46 | ColumnfusionIoDimmInfoPCIBandwidthCompatibility | read-only | mandatory | The bandwidth compatibility of the PCI-E slot. If the value is not optimal, the status and condition variables will be set accordingly. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.47 | ColumnfusionIoDimmInfoPCIPowerCompatibility | read-only | mandatory | The power compatibility of the PCI-E slot. If the value is not optimal, the status and condition variables will be set accordingly. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.48 | ColumnfusionIoDimmInfoActualGoverningLevel | read-only | mandatory | The level of governing currently happening on the device. This may be due to any of several reasons. Current reasons are because of high temperature, power sho… |
| 1.3.6.1.4.1.30018.1.2.1.1.1.49 | ColumnfusionIoDimmInfoLifespanGoverningLevel | read-only | obsolete | Governing may be impacted for the sake of prolonging longevity of the device. This value indicates the level of contribution for longevity. none = no governing… |
| 1.3.6.1.4.1.30018.1.2.1.1.1.50 | ColumnfusionIoDimmInfoPowerGoverningLevel | read-only | mandatory | Governing may be impacted due to a lack of power available to the device. This value indicates the level of contribution due to lack of power. none = no govern… |
| 1.3.6.1.4.1.30018.1.2.1.1.1.51 | ColumnfusionIoDimmInfoThermalGoverningLevel | read-only | mandatory | Governing may be impacted due to the device reaching high temperatures. This value indicates the level of contribution due to high temperatures. none = no gove… |
| 1.3.6.1.4.1.30018.1.2.1.1.1.52 | ColumnfusionIoDimmInfoLifespanGoverningEnabled | read-only | obsolete | A true condition indicates that lifespan governing is enabled. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.53 | ColumnfusionIoDimmInfoLifespanGoverningTgtDate | read-only | obsolete | The target lifespan governing date. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.54 | ColumnfusionIoDimmInfoInternalTempCritical | read-only | mandatory | A true condition indicates that temperature is at a critical level. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.55 | ColumnfusionIoDimmInfoInternalTempShutdown | read-only | mandatory | A true condition indicates that temperature is has surpassed a critical level and the device will shut down. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.56 | ColumnfusionIoDimmInfoPcieErrorsIndicator | read-only | mandatory | Indicates whether correctable or uncorrectable PCIe errors have been detected on the PCIe bus. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.57 | ColumnfusionIoDimmInfoMissingLebMapIndicator | read-only | mandatory | A true condition indicates the device is missing a LEB map and cannot be attached. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.58 | ColumnfusionIoDimmInfoVccIntErrorIndicator | read-only | mandatory | A true condition indicates the device is experiencing a VccInt out of range error. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.59 | ColumnfusionIoDimmInfoVccAuxErrorIndicator | read-only | mandatory | A true condition indicates the device is experiencing a VccAux out of range error. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.60 | ColumnfusionIoDimmInfoOverPowerIndicator | read-only | mandatory | A true condition indicates the device is experiencing an overpower error. Plug in external power to solve the problem. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.61 | ColumnfusionIoDimmInfoUpgradeInProgressIndicator | read-only | mandatory | A true condition indicates the device is currently in the process of being upgraded to a new major revision of the VSL driver. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.62 | ColumnfusionIoDimmInfoInternalTempHighThreshold | read-only | mandatory | Threshold at which temperature will be considered high (warning level) and temperature high trap will be fired. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.63 | ColumnfusionIoDimmInfoInternalTempCriticalThreshold | read-only | mandatory | Threshold at which temperature will be at a critical level and a critical temperature trap will be fired. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.64 | ColumnfusionIoDimmInfoInternalTempShutdownThreshold | read-only | mandatory | Threshold at which temperature will be at a shutdown level and a critical temperature trap will be fired. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.65 | ColumnfusionIoDimmInfoVirtualControllerNumber | read-only | mandatory | The number of this virtual controller on the physical ioMemory device. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.66 | ColumnfusionIoDimmInfoVirtualControllerCount | read-only | mandatory | The total number of active virtual controllers on the physical ioMemory device. |
| 1.3.6.1.4.1.30018.1.2.1.1.1.67 | ColumnfusionIoDimmInfoActiveMediaPercent | read-only | mandatory | The total active media on the device as a percent. |
| 1.3.6.1.4.1.30018.1.2.2 | NodefusionIoDimmExtn | |||
| 1.3.6.1.4.1.30018.1.2.2.1 | TablefusionIoDimmExtnTable | not-accessible | mandatory | Fusion-io ioDrive extension table. |
| 1.3.6.1.4.1.30018.1.2.2.1.1 | RowfusionIoDimmExtnEntry | not-accessible | mandatory | Represents an entry in the fusionIoDimmExtnTable. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.1 | ColumnfusionIoDimmExtnIndex | read-only | mandatory | The unique index for the ioDrive extension table. There should be an entry in this table for each entry in the ioDrive table. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.2 | ColumnfusionIoDimmExtnTotalPhysCapacityU | read-only | mandatory | The upper word of the max format size in bytes. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.3 | ColumnfusionIoDimmExtnTotalPhysCapacityL | read-only | mandatory | The lower word of the max format size in bytes. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.4 | ColumnfusionIoDimmExtnUsablePhysCapacityU | read-only | obsolete | The upper word of the usable physical capacity in bytes. This is space that is holding valid data, is erased and ready for writing or waiting to be reclaimed v… |
| 1.3.6.1.4.1.30018.1.2.2.1.1.5 | ColumnfusionIoDimmExtnUsablePhysCapacityL | read-only | obsolete | The lower word of the usable physical capacity in bytes. This is space that is holding valid data, is erased and ready for writing or waiting to be reclaimed v… |
| 1.3.6.1.4.1.30018.1.2.2.1.1.6 | ColumnfusionIoDimmExtnUsedPhysCapacityU | read-only | obsolete | The upper word used physical capacity in bytes. This is the space holding valid, current data. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.7 | ColumnfusionIoDimmExtnUsedPhysCapacityL | read-only | obsolete | The lower word used physical capacity in bytes. This is the space holding valid, current data. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.8 | ColumnfusionIoDimmExtnTotalLogCapacityU | read-only | mandatory | The upper word of the total logical capacity in bytes as formatted. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.9 | ColumnfusionIoDimmExtnTotalLogCapacityL | read-only | mandatory | The lower word of the total logical capacity in bytes as formatted. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.10 | ColumnfusionIoDimmExtnAvailLogCapacityU | read-only | obsolete | The upper word of the available logical capacity in bytes. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.11 | ColumnfusionIoDimmExtnAvailLogCapacityL | read-only | obsolete | The lower word of the available logical capacity in bytes. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.12 | ColumnfusionIoDimmExtnBytesReadU | read-only | mandatory | The upper word of the total number of bytes read since the device was formatted. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.13 | ColumnfusionIoDimmExtnBytesReadL | read-only | mandatory | The lower word of the total number of bytes read since the device was formatted. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.14 | ColumnfusionIoDimmExtnBytesWrittenU | read-only | mandatory | The upper word of the total bytes written. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.15 | ColumnfusionIoDimmExtnBytesWrittenL | read-only | mandatory | The lower word of the total bytes written. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.16 | ColumnfusionIoDimmExtnLogBytesWrittenU | read-only | obsolete | The upper word of the number of user data bytes written. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.17 | ColumnfusionIoDimmExtnLogBytesWrittenL | read-only | obsolete | The lower word of the number of user data bytes written. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.18 | ColumnfusionIoDimmExtnShortTermStartDate | read-write | obsolete | The start date used to characterize short-term drive usage. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.19 | ColumnfusionIoDimmExtnShortTermWindow | read-write | obsolete | The number of hours in the short-term usage characterization window. If this value is non-zero, then the short-term start date will automatically track with th… |
| 1.3.6.1.4.1.30018.1.2.2.1.1.20 | ColumnfusionIoDimmExtnShortTermEndDate | read-write | obsolete | The end date used to characterize short-term drive usage. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.21 | ColumnfusionIoDimmExtnShortTermEndDateFloat | read-write | obsolete | Set this variable true to automatically have the short-term end date automatically updated to the present date. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.22 | ColumnfusionIoDimmExtnLongTermStartDate | read-write | obsolete | The start date used to characterize long-term drive usage. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.23 | ColumnfusionIoDimmExtnLongTermWindow | read-write | obsolete | The number of hours in the long-term usage characterization window. If this value is non-zero, then the long-term start date will automatically track with the … |
| 1.3.6.1.4.1.30018.1.2.2.1.1.24 | ColumnfusionIoDimmExtnLongTermEndDate | read-write | obsolete | The end date used to characterize long-term drive usage. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.25 | ColumnfusionIoDimmExtnLongTermEndDateFloat | read-write | obsolete | Set this variable true to automatically have the long-term end date automatically updated to the present date. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.26 | ColumnfusionIoDimmExtnWriteRateAutoCalc | read-write | obsolete | Set this true to automatically calculate the long-term and short-term average write rate based on the start and end dates selected. Otherwise, the average writ… |
| 1.3.6.1.4.1.30018.1.2.2.1.1.27 | ColumnfusionIoDimmExtnShortTermAvgU | read-write | obsolete | The upper word of the short-term average write rate used to characterize drive usage. This will be automatically calculated based on short-term start and end d… |
| 1.3.6.1.4.1.30018.1.2.2.1.1.28 | ColumnfusionIoDimmExtnShortTermAvgL | read-write | obsolete | The lower word of the short-term average write rate used to characterize drive usage. This will be automatically calculated based on short-term start and end d… |
| 1.3.6.1.4.1.30018.1.2.2.1.1.29 | ColumnfusionIoDimmExtnLongTermAvgU | read-write | obsolete | The upper word of the long-term average write rate used to characterize drive usage. This will be automatically calculated based on long-term start and end dat… |
| 1.3.6.1.4.1.30018.1.2.2.1.1.30 | ColumnfusionIoDimmExtnLongTermAvgL | read-write | obsolete | The lower word of the long-term average write rate used to characterize drive usage. This will be automatically calculated based on long-term start and end dat… |
| 1.3.6.1.4.1.30018.1.2.2.1.1.31 | ColumnfusionIoDimmExtnConfidenceInterval | read-write | obsolete | This defines the confidence interval used to calculate the wearout and non-writable dates. Expressed as a percentage, this value reflects the confidence in the… |
| 1.3.6.1.4.1.30018.1.2.2.1.1.32 | ColumnfusionIoDimmExtnFormattedBlockSize | read-only | mandatory | The block size that this device is formatted to use. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.33 | ColumnfusionIoDimmExtnCurrentRAMUsageU | read-only | mandatory | The upper word of the current RAM usage in bytes for the drive. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.34 | ColumnfusionIoDimmExtnCurrentRAMUsageL | read-only | mandatory | The lower word of the current RAM usage in bytes for the drive. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.35 | ColumnfusionIoDimmExtnPeakRAMUsageU | read-only | mandatory | The upper word of the peak RAM usage in bytes for the drive. |
| 1.3.6.1.4.1.30018.1.2.2.1.1.36 | ColumnfusionIoDimmExtnPeakRAMUsageL | read-only | mandatory | The lower word of the peak RAM usage in bytes for the drive. |
| 1.3.6.1.4.1.30018.1.2.3 | NodefusionIoDimmCapacity | |||
| 1.3.6.1.4.1.30018.1.2.3.1 | TablefusionIoDimmCapacityTable | not-accessible | optional | A table of usable physical capacity values over time. |
| 1.3.6.1.4.1.30018.1.2.3.1.1 | RowfusionIoDimmCapacityEntry | not-accessible | optional | Defines an entry of the usable physical capacity history table. |
| 1.3.6.1.4.1.30018.1.2.3.1.1.1 | ColumnfusionIoDimmCapacityInfoIndex | read-only | optional | The ioDrive index. This correlates to the drive index in the info table. |
| 1.3.6.1.4.1.30018.1.2.3.1.1.2 | ColumnfusionIoDimmCapacityIndex | read-only | optional | Unique index for the usable physical capacity log. |
| 1.3.6.1.4.1.30018.1.2.3.1.1.3 | ColumnfusionIoDimmCapacityValueU | read-only | optional | The upper word of the physical usable capacity at this point in time. |
| 1.3.6.1.4.1.30018.1.2.3.1.1.4 | ColumnfusionIoDimmCapacityValueL | read-only | optional | The lower word of the physical usable capacity at this point in time. |
| 1.3.6.1.4.1.30018.1.2.3.1.1.5 | ColumnfusionIoDimmCapacityTimestamp | read-only | optional | The time stamp of this value entry. |
| 1.3.6.1.4.1.30018.1.2.4 | NodefusionIoDimmWrite | |||
| 1.3.6.1.4.1.30018.1.2.4.1 | TablefusionIoDimmWriteTable | not-accessible | optional | A log of write volume history. |
| 1.3.6.1.4.1.30018.1.2.4.1.1 | RowfusionIoDimmWriteEntry | not-accessible | optional | An entry in the write volume history table. |
| 1.3.6.1.4.1.30018.1.2.4.1.1.1 | ColumnfusionIoDimmWriteInfoIndex | read-only | optional | The ioDrive index. This correlates with the index in the info table. |
| 1.3.6.1.4.1.30018.1.2.4.1.1.2 | ColumnfusionIoDimmWriteIndex | read-only | optional | Unique index for this write volume entry. |
| 1.3.6.1.4.1.30018.1.2.4.1.1.3 | ColumnfusionIoDimmWriteValueU | read-only | optional | The upper word of the total physical number of bytes written at a given moment in time. |
| 1.3.6.1.4.1.30018.1.2.4.1.1.4 | ColumnfusionIoDimmWriteValueL | read-only | optional | The lower word of the total physical number of bytes written at a given moment in time. |
| 1.3.6.1.4.1.30018.1.2.4.1.1.5 | ColumnfusionIoDimmWriteTimestamp | read-only | optional | The timestamp entry for this value. |
| 1.3.6.1.4.1.30018.1.2.5 | NodefusionIoDimmTemp | |||
| 1.3.6.1.4.1.30018.1.2.5.1 | TablefusionIoDimmTempTable | not-accessible | optional | Device temperature history table. |
| 1.3.6.1.4.1.30018.1.2.5.1.1 | RowfusionIoDimmTempEntry | not-accessible | optional | Device temperature history entry. |
| 1.3.6.1.4.1.30018.1.2.5.1.1.1 | ColumnfusionIoDimmTempInfoIndex | read-only | optional | The device index. This correlates to the index in the info table. |
| 1.3.6.1.4.1.30018.1.2.5.1.1.2 | ColumnfusionIoDimmTempIndex | read-only | optional | Unique index for this temperature log entry. |
| 1.3.6.1.4.1.30018.1.2.5.1.1.3 | ColumnfusionIoDimmTempValue | read-only | optional | The current temperature of the device in Celsius.. |
| 1.3.6.1.4.1.30018.1.2.5.1.1.4 | ColumnfusionIoDimmTempTimestamp | read-only | optional | The timestamp for this entry. |
| 1.3.6.1.4.1.30018.1.2.6 | NodefusionIoDimmProc | |||
| 1.3.6.1.4.1.30018.1.2.6.1 | TablefusionIoDimmProcTable | not-accessible | obsolete | A table of processes that support device operation. |
| 1.3.6.1.4.1.30018.1.2.6.1.1 | RowfusionIoDimmProcEntry | not-accessible | obsolete | Each entry represents a process. |
| 1.3.6.1.4.1.30018.1.2.6.1.1.1 | ColumnfusionIoDimmProcIndex | read-only | obsolete | A unique index for each process. |
| 1.3.6.1.4.1.30018.1.2.6.1.1.2 | ColumnfusionIoDimmProcName | read-only | obsolete | The process name. |
| 1.3.6.1.4.1.30018.1.2.6.1.1.3 | ColumnfusionIoDimmProcState | read-only | obsolete | The process state. |
| 1.3.6.1.4.1.30018.1.2.6.1.1.4 | ColumnfusionIoDimmProcRAM | read-only | obsolete | The bytes of RAM currently in use by the process. |
| 1.3.6.1.4.1.30018.1.2.6.1.1.5 | ColumnfusionIoDimmProcCPU | read-only | obsolete | The overall percentage of CPU usage. |
| 1.3.6.1.4.1.30018.25 | ScalarfusionIoDimmTrapFlags | read-only | obsolete | This is a collection of flags used only during trap delivery. Each bit has the following meaning: Bit 5-31: Reserved (always 0) Bit 2-4: Trap Condition 0 = Not… |
| 1.3.6.1.4.1.30018.1001 | NodefusionIoDimmWearoutTrap | Generated when the device begins to wear out. | ||
| 1.3.6.1.4.1.30018.1002 | NodefusionIoDimmNonWritableTrap | Generated when the device is in write-reduced or non-writable mode based on the fusionIoDimmInfoWritableIndicator. This can be due to excessive wear or other d… | ||
| 1.3.6.1.4.1.30018.1003 | NodefusionIoDimmFlashbackTrap | Generated when flashback protection becomes degraded. | ||
| 1.3.6.1.4.1.30018.1004 | NodefusionIoDimmTempHighTrap | Generated when the temperature sensor surpasses the warning threshold. | ||
| 1.3.6.1.4.1.30018.1005 | NodefusionIoDimmTempOkTrap | Generated when temperature returns to a safe level. | ||
| 1.3.6.1.4.1.30018.1006 | NodefusionIoDimmErrorTrap | Generated when device is in an error state. | ||
| 1.3.6.1.4.1.30018.1007 | NodefusionIoDimmPowerlossProtectTrap | Generated when the powerloss protection feature is available but disabled. | ||
| 1.3.6.1.4.1.30018.1008 | NodefusionIoDimmCriticalTempTrap | Generated when the temperature sensor is at a critical threshold. | ||
| 1.3.6.1.4.1.30018.1009 | NodefusionIoDimmShutdownTempTrap | Generated when the temperature sensor surpasses the shutdown threshold. | ||
| 1.3.6.1.4.1.30018.1010 | NodefusionIoDimmPcieErrorsTrap | Generated when PCIe bus errors are detected. | ||
| 1.3.6.1.4.1.30018.1011 | NodefusionIoDimmMissingLebMapTrap | Generated when the ioMemory is found to be missing a LEB map. | ||
| 1.3.6.1.4.1.30018.1012 | NodefusionIoDimmSlotBandwidthIncompatibleTrap | Generated when the ioMemory is found to be in an incompatible PCIe slot. | ||
| 1.3.6.1.4.1.30018.1013 | NodefusionIoDimmSlotBandwidthSuboptimalTrap | Generated when the ioMemory is found to be in an sub-optimal PCIe slot. | ||
| 1.3.6.1.4.1.30018.1014 | NodefusionIoDimmLowReservesTrap | Generated when the ioMemory is low on reserve space, but not yet depleted. | ||
| 1.3.6.1.4.1.30018.1015 | NodefusionIoDimmVccIntTrap | Generated when the ioMemory is out of range for vccint. | ||
| 1.3.6.1.4.1.30018.1016 | NodefusionIoDimmVccAuxTrap | Generated when the ioMemory is out of range for vccaux. | ||
| 1.3.6.1.4.1.30018.1017 | NodefusionIoDimmMinimalModeTrap | Generated when the ioMemory is in minimal mode. | ||
| 1.3.6.1.4.1.30018.1018 | NodefusionIoDimmOverPowerTrap | Generated when the ioMemory is using too much power. Plug in an external power cable to correct the issue. | ||
| 1.3.6.1.4.1.30018.1019 | NodefusionIoDimmUpgradeInProgressTrap | Generated when the ioMemory is in the process of upgrading to a new major driver version. |
Type Definitions
| Name | Syntax | Status | Description |
|---|---|---|---|
| Boolean | INTEGER { true(1), false(2) } |