MIB Viewer

Fore-SSM-MIB

13 objects
Synchronization Status Message Module
Imported Objects
Fore-Switch-MIBsyncStatusMsgGroup
SNMPv2-SMIMODULE-IDENTITY NOTIFICATION-TYPE OBJECT-TYPE
SNMPv2-TCDisplayString
OIDNameAccessStatusDescription
1.3.6.1.4.1.326.2.2.2.1.21.0.1NotificationsyncStatusMsgChangedcurrentThis trap is generated whenever a configured timing reference's receive SSM changes. It indicates the previous SSM received and the new SSM being received.
1.3.6.1.4.1.326.2.2.2.1.21.1TablesyncStatusMsgTablenot-accessiblecurrentA table containing Synchronization Status Message configuration and status.
1.3.6.1.4.1.326.2.2.2.1.21.1.1RowsyncStatusMsgEntrynot-accessiblecurrentA table entry containing Synchronization Status Message configuration and status.
1.3.6.1.4.1.326.2.2.2.1.21.1.1.1ColumnsyncStatusMsgInterfacenot-accessiblecurrentName of this SSM Interface.
1.3.6.1.4.1.326.2.2.2.1.21.1.1.2ColumnsyncStatusMsgRxMessageread-onlycurrentSynchronization Status Message currently being received on this interface. If syncStatusMsgForceRxSsm is set to any value other than SyncStatusMsgType::none, t…
1.3.6.1.4.1.326.2.2.2.1.21.1.1.3ColumnsyncStatusMsgTxMessageread-onlycurrentSynchronization Status Message being transmitted on this interface. If syncStatusMsgForceDus is set to enabled, then syncStatusMsgTxMessage will be Don't Use f…
1.3.6.1.4.1.326.2.2.2.1.21.1.1.4ColumnsyncStatusMsgForceRxSsmread-writecurrentThis variable is used to force a particual Synchronization Status Message as the receive SSM on this interface. Forcing a receive SSM will cause the interface …
1.3.6.1.4.1.326.2.2.2.1.21.1.1.5ColumnsyncStatusMsgForceDusread-writecurrentIndicates if Don't Use for Synchronization (DUS) is being forced on the transmit side of this interface. If this variable is set to enabled, then the switch wi…
1.3.6.1.4.1.326.2.2.2.1.21.1.1.6ColumnsyncStatusMsgPrevRxMessageaccessible-for-notifycurrentSynchronization Status Message previously received on this interface. This variable is used by syncStatusMsgChanged trap.
1.3.6.1.4.1.326.2.2.2.1.21.2ScalarsyncStatusMsgAutomaticRefSwitchingread-writecurrentIndicates whether or not changes in SSM will cause automatic reference switching. If the variable is set to enabled, the switch will process and react to chang…
1.3.6.1.4.1.326.2.2.2.1.21.3ScalarsyncStatusMsgSdhOptionread-writecurrentIndicates the SSM Option being used on SDH/E1 interfaces. Default value is optionII.
1.3.6.1.4.1.326.2.2.2.1.21.4IdentitysysStatusMsgModuleSynchronization Status Message Module
Type Definitions
NameSyntaxStatusDescription
SyncStatusMsgTypeINTEGER { prs(1), prc(2), stu(3), st2(4), tncssua(5), st3e(8), ssub(9), st3(10), sec(11), smc(12), st4(13), res(15), dus(16), invalid(100), none(101) }