MIB Viewer

GDC-SC800T3-MIB

153 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.498.19Nodeds3
1.3.6.1.4.1.498.19.1Nodesc800t3
1.3.6.1.4.1.498.19.1.1Nodesc800t3Version
1.3.6.1.4.1.498.19.1.1.1Scalarsc800t3MIBversionread-onlymandatoryIdentifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number…
1.3.6.1.4.1.498.19.1.1.2Tablesc800t3VersionTablenot-accessiblemandatory
1.3.6.1.4.1.498.19.1.1.2.1Rowsc800t3VersionEntrynot-accessiblemandatoryAn entry in the GDC SC800T3 Version Table.
1.3.6.1.4.1.498.19.1.1.2.1.1Columnsc800t3VersionIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.1.2.1.2Columnsc800t3ActiveFirmwareRevread-onlymandatoryThe version number of the firmware currently executing. The format is MM.NN.BB where: MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix Revision …
1.3.6.1.4.1.498.19.1.1.2.1.3Columnsc800t3StandbyFirmwareRevread-onlymandatoryThe version number of the firmware stored (in a compressed format) but not currently executing. MM: Major Revision (0-99) NN: Minor Revision (0-99) BB: Bug Fix…
1.3.6.1.4.1.498.19.1.1.2.1.4Columnsc800t3StoredFirmwareStatusread-onlymandatoryThis object represents the state of the Non-Active or Stored firmware: statBlank(1) Factory Default statDownLoading(2) In process of downloading firmware statO…
1.3.6.1.4.1.498.19.1.1.2.1.5Columnsc800t3SwitchActiveFirmwareread-writemandatoryThis object is used to switch the active executing firmware from the version in sc800t3ActiveRev to the version in sc800t3StoredRev. When a switchActive(2) is …
1.3.6.1.4.1.498.19.1.1.2.1.6Columnsc800t3DownloadingModeread-writemandatoryThis object is used to configure the download mode: disableAll(1) Prevents any firmware downloading to SC800T3 enableAndWait(2) Allows downloading zipped code …
1.3.6.1.4.1.498.19.1.1.2.1.7Columnsc800t3EraseFlashread-writemandatoryA set of this object to erase(2) will erase the application stored in flash. After setting this object, there should be a delay of at least 2 minutes before do…
1.3.6.1.4.1.498.19.1.2Nodesc800t3Configuration
1.3.6.1.4.1.498.19.1.2.1Tablesc800t3ChannelConfigTablenot-accessiblemandatoryThe GDC SC800T3 Channel Configuration table.
1.3.6.1.4.1.498.19.1.2.1.1Rowsc800t3ChannelConfigEntrynot-accessiblemandatoryThe sc800t3 Channel Configuration table entry.
1.3.6.1.4.1.498.19.1.2.1.1.1Columnsc800t3ChannelConfigIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.2.1.1.2Columnsc800t3ForcedDCEread-writemandatoryControls the operation of Data Communications Equipment (DCE) signal. The value followsDte(1) indicates that the channel's DCE follows Data Terminal Equipment …
1.3.6.1.4.1.498.19.1.2.1.1.3Columnsc800t3ChannelDTEtestread-writemandatoryDTE interface supporting loop A and loop B tests. See ANSI TIA/EIA-613-1993 specification for details on encoding of inter changes.
1.3.6.1.4.1.498.19.1.2.1.1.4Columnsc800t3DTELoopTimeoutread-writemandatoryEnables/disables DTE loop time out.
1.3.6.1.4.1.498.19.1.2.2Tablesc800t3NetworkConfigTablenot-accessiblemandatoryThe GDC SC800T3 Network Configuration table.
1.3.6.1.4.1.498.19.1.2.2.1Rowsc800t3NetworkConfigEntrynot-accessiblemandatoryThe sc800t3 Network Configuration table entry.
1.3.6.1.4.1.498.19.1.2.2.1.1Columnsc800t3NetworkConfigIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.2.2.1.2Columnsc800t3NetworkFrameTyperead-writemandatoryIs the framing type of the network interface. Setting the value of the object to m13(1) configures the network interface to M-13 framing. Setting the value of …
1.3.6.1.4.1.498.19.1.2.2.1.3Columnsc800t3NetworkTransmitClockSourceread-writemandatoryThe DSU transmit clock source option. This is the selection for the transmitter timing clock source.
1.3.6.1.4.1.498.19.1.2.2.1.4Columnsc800t3NetworkAISLoopdownread-writemandatoryThe time in seconds when receiving a continuous AIS signal before a remotely initiated loopback is terminated. When this object has the value 4, then there is …
1.3.6.1.4.1.498.19.1.2.2.1.5Columnsc800t3NetworkLineTyperead-writemandatoryThe operating mode of the interface. Setting the value of this object to longCable(1) configures the interface as standard DS-3. Setting the value of this obje…
1.3.6.1.4.1.498.19.1.2.2.1.6Columnsc800t3NetworkIdleStatusread-onlymandatoryReturns a value of received(2) when the sc800t3 receives a DS3 idle from the network.
1.3.6.1.4.1.498.19.1.2.2.1.7Columnsc800t3NetworkTransmitIdleStatusread-writemandatoryWhen set to active(2), the sc800t3 will transmit a DS3 idle signal to the network.
1.3.6.1.4.1.498.19.1.2.2.1.8Columnsc800t3NetworkSesBERThresholdread-writemandatoryWhen set to thresone(1), the SES BER threshold will be set to 1X10^-6 and when it is set to thresseven(2), it will be set to 7.5X10^-5.
1.3.6.1.4.1.498.19.1.2.2.1.9Columnsc800t3InbandLoopbackread-writemandatoryEnables/disables the inband loop back.
1.3.6.1.4.1.498.19.1.3Nodesc800t3Diagnostics
1.3.6.1.4.1.498.19.1.3.1Tablesc800t3DiagTablenot-accessiblemandatoryThe SC800T3 Diagnostics table.
1.3.6.1.4.1.498.19.1.3.1.1Rowsc800t3DiagEntrynot-accessiblemandatoryThe SNMPSC800T3 Diagnostics table entry.
1.3.6.1.4.1.498.19.1.3.1.1.1Columnsc800t3DiagIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.3.1.1.2Columnsc800t3DiagTestDurationread-writemandatorySelects the duration to run a diagnostic test.
1.3.6.1.4.1.498.19.1.3.1.1.3Columnsc800t3InsertBitErrorread-writemandatoryA set of 2 will insert one bit error for test. Management may only write a 2. A 1 will always be read.
1.3.6.1.4.1.498.19.1.3.1.1.4Columnsc800t3DiagT3Testread-writemandatoryA set of 2-11 starts the specified test and a set of t3NoTest(1) stops the current running test. A get returns the current active test.
1.3.6.1.4.1.498.19.1.3.1.1.5Columnsc800t3DiagTestResultsread-onlymandatoryReturns a the folowing bytes. Octet 1 bit 7 - F/U bit 6 - 1: Test complete bit 5 - 1: Test aborted bit 4 - F/U bit 3 - remote status 0: inactive 1: active bit …
1.3.6.1.4.1.498.19.1.3.1.1.6Columnsc800t3DiagResetTestResultsread-writemandatoryThis object will clear the results register while running any test except for Network Delay. Starting a new test will automatically zero out the register. A no…
1.3.6.1.4.1.498.19.1.4Nodesc800t3Maintenance
1.3.6.1.4.1.498.19.1.4.1Tablesc800t3MaintenanceTablenot-accessiblemandatoryThe table describes the maintenance functions for the sc800t3.
1.3.6.1.4.1.498.19.1.4.1.1Rowsc800t3MaintenanceEntrynot-accessiblemandatoryAn entry in the GDC maintenance Table
1.3.6.1.4.1.498.19.1.4.1.1.1Columnsc800t3MaintenanceIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.4.1.1.2Columnsc800t3LedStatusread-onlymandatoryReturns a bitwise snapshot of the front panel LED state and front panel switches. Octet 1 bit 7 - f/u bit 6 - NTWK 0:LED off 1:LED on bit 5 - TM 0:LED off 1:LE…
1.3.6.1.4.1.498.19.1.4.1.1.3Columnsc800t3SoftResetread-writemandatorySupports the action of soft resetting the unit. When this object is set to reset(1), then the unit performs a soft reset. The value norm will be returned when …
1.3.6.1.4.1.498.19.1.4.1.1.4Columnsc800t3DefaultInitread-writemandatoryThis is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault, the unit will reset to the …
1.3.6.1.4.1.498.19.1.4.1.1.5Columnsc800t3ValidNearEndIntervalsread-onlymandatoryThe number of previous near end intervals for which valid data was collected. The value will be 31 unless the interface was brought on-line within the last 7.7…
1.3.6.1.4.1.498.19.1.4.1.1.6Columnsc800t3ValidFarEndIntervalsread-onlymandatoryThe number of previous far end intervals for which valid data was collected. The value will be 31 unless the interface was brought on-line within the last 7.75…
1.3.6.1.4.1.498.19.1.4.1.1.7Columnsc800t3ShelfTyperead-onlymandatoryType of shelf the sc800t3 is located in.
1.3.6.1.4.1.498.19.1.4.1.1.8Columnsc800t3TwinPackPowerSupplyread-onlymandatoryPower supplies currently installed in Twin Pack. When the sc800t3 is located in a Spectracomm shelf none(1) will always be returned.
1.3.6.1.4.1.498.19.1.4.1.1.9Columnsc800t3TestAllLedsread-writemandatoryThis variable is used to test the front panel leds and individual segments of the display. A one (1) will turn all leds and display segments on. They will rema…
1.3.6.1.4.1.498.19.1.4.1.1.10Columnsc800t3NearEndResetStatsread-writemandatorySupports the action of soft resetting the sc800t3ValidNearEndIntervals object. When this object is set to reset(2), then the unit will reset the sc800t3ValidNe…
1.3.6.1.4.1.498.19.1.4.1.1.11Columnsc800t3FarEndResetStatsread-writemandatorySupports the action of soft resetting the sc800t3ValidFarEndIntervals object. When this object is set to reset(2), then the unit will reset the sc800t3ValidFar…
1.3.6.1.4.1.498.19.1.4.1.1.12Columnsc800t3NearEndStatLastInitialread-onlymandatoryNumber of seconds from midnight Dec 31 1969 up until sc800t3ValidNearEndIntervals was last initialized to zero.
1.3.6.1.4.1.498.19.1.4.1.1.13Columnsc800t3FarEndStatLastInitialread-onlymandatoryNumber of seconds from midnight Dec 31 1969 up until sc800t3ValidFarEndIntervals was last initialized to zero.
1.3.6.1.4.1.498.19.1.5Nodesc800t3Alarms
1.3.6.1.4.1.498.19.1.5.1Nodesc800t3NoResponse
1.3.6.1.4.1.498.19.1.5.2Nodesc800t3DiagRxErrAlm
1.3.6.1.4.1.498.19.1.5.3Nodesc800t3PowerUpAlm
1.3.6.1.4.1.498.19.1.5.4Nodesc800t3POSTFail
1.3.6.1.4.1.498.19.1.5.5Nodesc800t3UnsolicitedTest
1.3.6.1.4.1.498.19.1.5.6Nodesc800t3ConfigChange
1.3.6.1.4.1.498.19.1.5.7Nodesc800t3TimingLoss
1.3.6.1.4.1.498.19.1.5.8Nodesc800t3LossOfSignal
1.3.6.1.4.1.498.19.1.5.9Nodesc800t3OutOfFrame
1.3.6.1.4.1.498.19.1.5.10Nodesc800t3AIS
1.3.6.1.4.1.498.19.1.5.11Nodesc800t3DTEReadyLoss
1.3.6.1.4.1.498.19.1.5.12Nodesc800t3DTETXCLKLoss
1.3.6.1.4.1.498.19.1.5.13Nodesc800t3RXDNoTrans
1.3.6.1.4.1.498.19.1.5.14Nodesc800t3TXDNoTrans
1.3.6.1.4.1.498.19.1.5.15Nodesc800t3RemoteNotResponding
1.3.6.1.4.1.498.19.1.5.16Nodesc800t3TopPowerSupplyFail
1.3.6.1.4.1.498.19.1.5.17Nodesc800t3BottomPowerSupplyFail
1.3.6.1.4.1.498.19.1.5.18Nodesc800t3DTETest
1.3.6.1.4.1.498.19.1.5.19Nodesc800t3RAI
1.3.6.1.4.1.498.19.1.5.20Nodesc800t3ES
1.3.6.1.4.1.498.19.1.5.21Nodesc800t3SES
1.3.6.1.4.1.498.19.1.5.22Nodesc800t3SAS
1.3.6.1.4.1.498.19.1.5.23Nodesc800t3UAS
1.3.6.1.4.1.498.19.1.5.24Nodesc800t3CodeViolations
1.3.6.1.4.1.498.19.1.5.25Nodesc800t3ESline
1.3.6.1.4.1.498.19.1.6Nodesc800t3Performance
1.3.6.1.4.1.498.19.1.6.1Tablesc800t3CurrentNearEndTablenot-accessiblemandatoryGives the statistic count for the current 15 minute interval.
1.3.6.1.4.1.498.19.1.6.1.1Rowsc800t3CurrentNearEndEntrynot-accessiblemandatoryAn entry in the sc800t3 CurrentNearEnd table.
1.3.6.1.4.1.498.19.1.6.1.1.1Columnsc800t3CurrentNearEndIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.6.1.1.2Columnsc800t3CurrentNearEndStatread-onlymandatoryReturns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds …
1.3.6.1.4.1.498.19.1.6.2Tablesc800t3PreviousDayNearEndTablenot-accessiblemandatoryGives totals for the previous day of all the near end statistics.
1.3.6.1.4.1.498.19.1.6.2.1Rowsc800t3PreviousDayNearEndEntrynot-accessiblemandatoryAn entry in the sc800t3 PreviousDayNearEndTable.
1.3.6.1.4.1.498.19.1.6.2.1.1Columnsc800t3PreviousDayNearEndIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.6.2.1.2Columnsc800t3PreviousDayNearEndStatread-onlymandatoryReturns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Err…
1.3.6.1.4.1.498.19.1.6.3Tablesc800t3CurrentFarEndTablenot-accessiblemandatoryGives the statistic count for the current 15 minute interval.
1.3.6.1.4.1.498.19.1.6.3.1Rowsc800t3CurrentFarEndEntrynot-accessiblemandatoryAn entry in the sc800t3 CurrentFarEnd table.
1.3.6.1.4.1.498.19.1.6.3.1.1Columnsc800t3CurrentFarEndIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.6.3.1.2Columnsc800t3CurrentFarEndStatread-onlymandatoryReturns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds …
1.3.6.1.4.1.498.19.1.6.4Tablesc800t3CurrentDayNearEndTablenot-accessiblemandatoryGives totals for the current day of all the near end statistics.
1.3.6.1.4.1.498.19.1.6.4.1Rowsc800t3CurrentDayNearEndEntrynot-accessiblemandatoryAn entry in the sc800t3 CurrentDayNearEndTable.
1.3.6.1.4.1.498.19.1.6.4.1.1Columnsc800t3CurrentDayNearEndIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.6.4.1.2Columnsc800t3CurrentDayNearEndStatread-onlymandatoryReturns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Err…
1.3.6.1.4.1.498.19.1.6.5Tablesc800t3PreviousDayFarEndTablenot-accessiblemandatoryGives totals for the previous day of all the Far End statistics.
1.3.6.1.4.1.498.19.1.6.5.1Rowsc800t3PreviousDayFarEndEntrynot-accessiblemandatoryAn entry in the sc800t3PreviousDayFarEndTable.
1.3.6.1.4.1.498.19.1.6.5.1.1Columnsc800t3PreviousDayFarEndIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.6.5.1.2Columnsc800t3PreviousDayFarEndStatread-onlymandatoryReturns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Err…
1.3.6.1.4.1.498.19.1.6.6Tablesc800t3CurrentDayFarEndTablenot-accessiblemandatoryGives totals for the current day of all the Far End statistics.
1.3.6.1.4.1.498.19.1.6.6.1Rowsc800t3CurrentDayFarEndEntrynot-accessiblemandatoryAn entry in the sc800t3CurrentDayFarEndTable.
1.3.6.1.4.1.498.19.1.6.6.1.1Columnsc800t3CurrentDayFarEndIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.6.6.1.2Columnsc800t3CurrentDayFarEndStatread-onlymandatoryReturns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - n/a bit 1 - 2^15 Err…
1.3.6.1.4.1.498.19.1.6.7Tablesc800t3NearEndIntervalTablenot-accessiblemandatoryThe sc800t3 Near End Interval table.
1.3.6.1.4.1.498.19.1.6.7.1Rowsc800t3NearEndIntervalEntrynot-accessiblemandatoryAn entry in the Interval table.
1.3.6.1.4.1.498.19.1.6.7.1.1Columnsc800t3NearEndIntervalIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.6.7.1.2Columnsc800t3NearEndIntervalNumberread-onlymandatoryA number between 1 and 31, where 1 is the most recently completed minute interval and 31 is the least recently completed 15 minutes interval (assuming that all…
1.3.6.1.4.1.498.19.1.6.7.1.3Columnsc800t3NearEndIntervalStatsread-onlymandatoryReturns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds …
1.3.6.1.4.1.498.19.1.6.9Tablesc800t3FarEndIntervalTablenot-accessiblemandatoryThe sc800t3 Far End Interval table.
1.3.6.1.4.1.498.19.1.6.9.1Rowsc800t3FarEndIntervalEntrynot-accessiblemandatoryAn entry in the Interval table.
1.3.6.1.4.1.498.19.1.6.9.1.1Columnsc800t3FarEndIntervalIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.6.9.1.2Columnsc800t3FarEndIntervalNumberread-onlymandatoryA number between 1 and 31, where 1 is the most recently completed minute interval and 31 is the least recently completed 15 minutes interval (assuming that all…
1.3.6.1.4.1.498.19.1.6.9.1.3Columnsc800t3FarEndIntervalStatsread-onlymandatoryReturns a bitwise snapshot of the statistics. Octet 1 bit 7 - parity bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds …
1.3.6.1.4.1.498.19.1.6.10Tablesc800t3PreviousNearEndTablenot-accessiblemandatoryGives the statistic count for the previous 15 minute interval.
1.3.6.1.4.1.498.19.1.6.10.1Rowsc800t3PreviousNearEndEntrynot-accessiblemandatoryAn entry in the sc800t3 PreviousNearEnd table.
1.3.6.1.4.1.498.19.1.6.10.1.1Columnsc800t3PreviousNearEndIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.6.10.1.2Columnsc800t3PreviousNearEndStatread-onlymandatoryReturns a bitwise snapshot of the statistics. Octet 1 bit 7 - f/u bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES…
1.3.6.1.4.1.498.19.1.6.11Tablesc800t3PreviousFarEndTablenot-accessiblemandatoryGives the statistic count for the previous 15 minute interval.
1.3.6.1.4.1.498.19.1.6.11.1Rowsc800t3PreviousFarEndEntrynot-accessiblemandatoryAn entry in the sc800t3 PreviousFarEnd table.
1.3.6.1.4.1.498.19.1.6.11.1.1Columnsc800t3PreviousFarEndIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.6.11.1.2Columnsc800t3PreviousFarEndStatread-onlymandatoryReturns a bitwise snapshot of the statistics. Octet 1 bit 7 - f/u bit 6 - Invalid Data Flag bit 5 - n/a bit 4 - n/a bit 3 - n/a bit 2 - 2^9 Errored Seconds (ES…
1.3.6.1.4.1.498.19.1.7Nodesc800t3AlarmConfig
1.3.6.1.4.1.498.19.1.7.1Tablesc800t3AlarmConfigTablenot-accessiblemandatoryThe sc800t3AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit…
1.3.6.1.4.1.498.19.1.7.1.1Rowsc800t3AlarmConfigEntrynot-accessiblemandatoryAn entry in the GDC Alarm Configuration table.
1.3.6.1.4.1.498.19.1.7.1.1.1Columnsc800t3AlarmConfigIndexread-onlymandatoryInteger value which uniquely identifies the SC800T3 to which this entry is applicable. SCinstance is defined to be SLDi where: S (byte value) - physical shelf …
1.3.6.1.4.1.498.19.1.7.1.1.2Columnsc800t3AlarmConfigIdentifierread-onlymandatoryformat: iso.org.dod.internet.private.enterprises.gdc. ds3.sc800t3.sc800t3Alarms.ALM example: 1.3.6.1.4.1.498.19.1.5.ALM where ALM = 1 for sc800t3NoResponse ala…
1.3.6.1.4.1.498.19.1.7.1.1.3Columnsc800t3AlarmCountWindowread-writemandatoryThis variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting.
1.3.6.1.4.1.498.19.1.7.1.1.4Columnsc800t3AlarmCountThresholdread-writemandatoryThis function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given t…
1.3.6.1.4.1.498.19.1.8Nodesc800t3LocalAlarms
1.3.6.1.4.1.498.19.1.8.1Tablesc800t3LocalAlarmConfigTablenot-accessiblemandatoryThe sc800t3LocalAlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a…
1.3.6.1.4.1.498.19.1.8.1.1Rowsc800t3LocalAlarmConfigEntrynot-accessiblemandatoryAn entry in the GDC Local Alarm Configuration table.
1.3.6.1.4.1.498.19.1.8.1.1.1Columnsc800t3LocalAlarmConfigIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable.
1.3.6.1.4.1.498.19.1.8.1.1.2Columnsc800t3OOFread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.3Columnsc800t3AISLOCALread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.4Columnsc800t3TIMLOSread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.5Columnsc800t3TXDLOSread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.6Columnsc800t3RXDLOSread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.7Columnsc800t3LOSread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.8Columnsc800t3TPSFAILread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.9Columnsc800t3BPSFAILread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.10Columnsc800t3DTECLKLOSread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.11Columnsc800t3DTERDYLOSread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.12Columnsc800t3RAILOCALread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.13Columnsc800t3THRESHESLread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.14Columnsc800t3THRESHESread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.15Columnsc800t3THRESHSESread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.16Columnsc800t3THRESHSASread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.17Columnsc800t3THRESHUASread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.
1.3.6.1.4.1.498.19.1.8.1.1.18Columnsc800t3THRESHCVread-writemandatoryDisables or enables the alarm on the Major buss or Minor buss.