GDCMP7001-MIB
148 objects
No module-level DESCRIPTION found.
Imported Objects
| OID | Name | Access | Status | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.498 | Nodegdc | |||
| 1.3.6.1.4.1.498.6 | Nodedsx1 | |||
| 1.3.6.1.4.1.498.6.10 | Nodemp7001System | |||
| 1.3.6.1.4.1.498.6.10.1 | Nodemp7001Version | |||
| 1.3.6.1.4.1.498.6.10.1.1 | Scalarmp7001MIBversion | read-only | mandatory | Identifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number… |
| 1.3.6.1.4.1.498.6.10.1.2 | Tablemp7001VersionTable | not-accessible | mandatory | |
| 1.3.6.1.4.1.498.6.10.1.2.1 | Rowmp7001VersionEntry | not-accessible | mandatory | An entry in the GDC Mp7001System Version Table. |
| 1.3.6.1.4.1.498.6.10.1.2.1.1 | Columnmp7001VersionIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.1.2.1.2 | Columnmp7001FirmwareRev | read-only | mandatory | |
| 1.3.6.1.4.1.498.6.10.1.2.1.3 | Columnmp7001CardType | read-only | mandatory | This variable is used to determine the type of card family installed ex. MP7001. |
| 1.3.6.1.4.1.498.6.10.1.2.1.4 | Columnmp7001BootRev | read-only | mandatory | |
| 1.3.6.1.4.1.498.6.10.2 | Nodemp7001Maintenance | |||
| 1.3.6.1.4.1.498.6.10.2.1 | Tablemp7001MaintenanceTable | not-accessible | mandatory | The table describes the maintenance objects for MP 7001. |
| 1.3.6.1.4.1.498.6.10.2.1.1 | Rowmp7001MaintenanceEntry | not-accessible | mandatory | An entry in the GDC 701 Maintenance Table. |
| 1.3.6.1.4.1.498.6.10.2.1.1.1 | Columnmp7001MaintenanceLineIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.2.1.1.2 | Columnmp7001SoftReset | read-write | mandatory | Supports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose meaning is specific to the type… |
| 1.3.6.1.4.1.498.6.10.2.1.1.3 | Columnmp7001SysUpTime | read-only | mandatory | This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MI… |
| 1.3.6.1.4.1.498.6.10.2.1.1.4 | Columnmp7001DefaultInit | read-write | mandatory | This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(2) the unit will perform a r… |
| 1.3.6.1.4.1.498.6.10.2.1.1.5 | Columnmp7001ResetStats | read-write | mandatory | Supports the action of soft resetting the mp7001ValidIntervals object. When this object is set to reset(2), then the unit will reset the mp7001ValidIntervals o… |
| 1.3.6.1.4.1.498.6.10.2.1.1.6 | Columnmp7001LedStatus | read-only | mandatory | Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - ON bit 5 - INSV bit 4 - RSP bit 3 - TMG bit 2 - future use bit 1 - fu… |
| 1.3.6.1.4.1.498.6.10.2.1.1.7 | Columnmp7001T1CircuitName | read-write | mandatory | Circuit name T1 is connected to. |
| 1.3.6.1.4.1.498.6.10.2.1.1.8 | Columnmp7001SetRealTime | read-write | mandatory | Number of seconds from midnight Dec 31, 1969. |
| 1.3.6.1.4.1.498.6.10.2.1.1.9 | Columnmp7001AlarmStatus | read-only | mandatory | Returns a bit-wise Status of alarms Octet 1 bit 7 - not used bit 6 - NTWK LOS bit 5 - NTWK LOF bit 4 - NWTK_AIS bit 3 - future use bit 2 - NTWK Received YELLOW… |
| 1.3.6.1.4.1.498.6.10.2.1.1.10 | Columnmp7001SystemTimingGenStatus | read-only | mandatory | Indicates if the units configured for primary or secondary system clock are actually supplying clock and if it is the 8hkz, 4mhz, or both. |
| 1.3.6.1.4.1.498.6.10.2.1.1.11 | Columnmp7001StatLastInitialized | read-only | mandatory | Number of seconds from midnight Dec 31, 1969 up until mp7001ValidIntervals was last initialized to zero |
| 1.3.6.1.4.1.498.6.10.2.1.1.12 | Columnmp7001ValidIntervals | read-only | mandatory | The number of previous intervals for which valid data was collected. The value will be 96 unless the interface was brought on-line within the last 24 hours, in… |
| 1.3.6.1.4.1.498.6.10.3 | Nodemp7001Configuration | |||
| 1.3.6.1.4.1.498.6.10.3.1 | Tablemp7001ConfigTable | not-accessible | mandatory | The GDC Configuration table. |
| 1.3.6.1.4.1.498.6.10.3.1.1 | Rowmp7001ConfigEntry | not-accessible | mandatory | The GDC Configuration table entry. |
| 1.3.6.1.4.1.498.6.10.3.1.1.1 | Columnmp7001ConfigIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.3.1.1.2 | Columnmp7001NetworkInterfaceType | read-write | mandatory | Sets the transmit range to DSX-1 short or DS-1 long |
| 1.3.6.1.4.1.498.6.10.3.1.1.3 | Columnmp7001TransmitClockSource | read-write | mandatory | Sets the transmit clock source. |
| 1.3.6.1.4.1.498.6.10.3.1.1.4 | Columnmp7001FallbackClockSource | read-write | mandatory | Identifies the fallback transmit clock source. |
| 1.3.6.1.4.1.498.6.10.3.1.1.5 | Columnmp7001PreEqualization | read-write | mandatory | Pre-Equalization distance |
| 1.3.6.1.4.1.498.6.10.3.1.1.6 | Columnmp7001Framing | read-write | mandatory | Set the framing for the interface. Abbreviations are as follows: eSF - Extended Super Frame d4 - Super Frame |
| 1.3.6.1.4.1.498.6.10.3.1.1.7 | Columnmp7001LineCoding | read-write | mandatory | Sets the line coding for the interface. |
| 1.3.6.1.4.1.498.6.10.3.1.1.8 | Columnmp7001LineBuildout | read-write | mandatory | Sets the line build out for the interface 0, -7.5, -15 or -22.5dB |
| 1.3.6.1.4.1.498.6.10.3.1.1.9 | Columnmp7001FDLMode | read-write | mandatory | Sets the Facility Data Link Mode. |
| 1.3.6.1.4.1.498.6.10.3.1.1.10 | Columnmp7001FramingMode | read-write | mandatory | Sets the framing mode |
| 1.3.6.1.4.1.498.6.10.3.1.1.11 | Columnmp7001Loopback | read-write | mandatory | Sets the loopback type |
| 1.3.6.1.4.1.498.6.10.3.1.1.12 | Columnmp7001AISLoopdown | read-write | mandatory | Sets AIS unloop time where 4 = inhibit, 5 thru 60 = number of seconds |
| 1.3.6.1.4.1.498.6.10.3.1.1.13 | Columnmp7001SignalMode | read-write | mandatory | Sets signalling mode |
| 1.3.6.1.4.1.498.6.10.3.1.1.14 | Columnmp7001LineBuildoutCtrl | read-write | mandatory | Sets the line buildout control |
| 1.3.6.1.4.1.498.6.10.3.2 | Tablemp7001DCCConfigurationTable | not-accessible | mandatory | The GDC DCC Configuration table. These are Diagnostic Channel configuration options. |
| 1.3.6.1.4.1.498.6.10.3.2.1 | Rowmp7001DCCConfigurationEntry | not-accessible | mandatory | The GDC Diagnostic Configuration table entry. |
| 1.3.6.1.4.1.498.6.10.3.2.1.1 | Columnmp7001DCCConfigurationIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.3.2.1.2 | Columnmp7001TimeSlot | read-write | mandatory | Time Slot DCC goes in |
| 1.3.6.1.4.1.498.6.10.3.2.1.3 | Columnmp7001Bandwidth | read-write | mandatory | Bandwidth to use: 8 kbps - bit 7 only 56 kbps - bits 0 - 6 64 kbps - all 8 bits |
| 1.3.6.1.4.1.498.6.10.4 | Nodemp7001Diagnostics | |||
| 1.3.6.1.4.1.498.6.10.4.1 | Tablemp7001DiagTable | not-accessible | mandatory | The GDC T1 Diagnostics table. Information in the entries of this table support diagnostics testing, both active testing via patterns, and passive testing via l… |
| 1.3.6.1.4.1.498.6.10.4.1.1 | Rowmp7001DiagEntry | not-accessible | mandatory | The GDC T1 Diagnostics table entry. |
| 1.3.6.1.4.1.498.6.10.4.1.1.1 | Columnmp7001DiagIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.4.1.1.2 | Columnmp7001TestPattern | read-write | mandatory | Test pattern for tests that use the pattern generator. |
| 1.3.6.1.4.1.498.6.10.4.1.1.3 | Columnmp7001DiagConfig | read-write | mandatory | Selects the test to run. noLoop(1) ends the test. |
| 1.3.6.1.4.1.498.6.10.4.1.1.4 | Columnmp7001TestLimit | read-write | mandatory | Selects the duration to run a diagnostic test. The value(1) noLimit signifies that the test should run indefinitely until explicitly terminated. |
| 1.3.6.1.4.1.498.6.10.4.1.1.5 | Columnmp7001TestExecutionStatus | read-only | mandatory | This variable reports the status of a test. notInTest(1) indicates a test is not running. testInProgress(2) indicates that a test is currently running. testCom… |
| 1.3.6.1.4.1.498.6.10.4.1.1.6 | Columnmp7001TestExceptions | read-only | mandatory | Indicates exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. This sum initially take the valu… |
| 1.3.6.1.4.1.498.6.10.4.1.1.7 | Columnmp7001TestResults | read-only | mandatory | The results of the last diagnostic test. This can be the current test running or the last completed test. Note that the interpretation of these results may be … |
| 1.3.6.1.4.1.498.6.10.4.1.1.8 | Columnmp7001ResetTestResults | read-only | mandatory | Resets the diagnostic error count. |
| 1.3.6.1.4.1.498.6.10.4.1.1.9 | Columnmp7001DS0Diag | read-write | mandatory | Defines a DS0 level diagnostic. Setting this object value to 0 disables a DS0 level diagnostic. Setting this object to a value from 1 to 32 enables a DS0 level… |
| 1.3.6.1.4.1.498.6.10.5 | Nodemp7001Performance | |||
| 1.3.6.1.4.1.498.6.10.5.1 | Tablemp7001InboundANSIperfTable | not-accessible | mandatory | The GDC ANSI Performance table. Information in the entries of this table support the ANSI Scheduled Performance Reports. Entries supply information for inbound… |
| 1.3.6.1.4.1.498.6.10.5.1.1 | Rowmp7001InboundANSIperfEntry | not-accessible | mandatory | The GDC ANSI Performance table entry. The information in this entry presents one of the 4 second periods performance data in the inbound direction. |
| 1.3.6.1.4.1.498.6.10.5.1.1.1 | Columnmp7001InboundANSIperfIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.5.1.1.2 | Columnmp7001InboundANSIseconds | read-only | mandatory | Identifies the reporting interval. This has the value 1 to 4 supporting up to the last 4 seconds of performance data. |
| 1.3.6.1.4.1.498.6.10.5.1.1.3 | Columnmp7001InboundANSICRCerrorEvents | read-only | mandatory | Identifies the magnitude of the error events in the interval which this entry represents. |
| 1.3.6.1.4.1.498.6.10.5.1.1.4 | Columnmp7001InboundANSIsevereErrors | read-only | mandatory | Identifies whether or not any severe errors were detected in the interval which this entry represents. |
| 1.3.6.1.4.1.498.6.10.5.1.1.5 | Columnmp7001InboundANSIframeErrors | read-only | mandatory | Identifies whether or not any framing errors were detected in the interval which this entry represents. |
| 1.3.6.1.4.1.498.6.10.5.1.1.6 | Columnmp7001InboundANSIcodeViolations | read-only | mandatory | Identifies whether or not any code violations were detected in the interval which this entry represents. |
| 1.3.6.1.4.1.498.6.10.5.1.1.7 | Columnmp7001InboundANSIcontrolledSlips | read-only | mandatory | Identifies whether or not any controlled slips were detected in the interval which this entry represents. |
| 1.3.6.1.4.1.498.6.10.5.1.1.8 | Columnmp7001InboundANSIactivePayloadLoops | read-only | mandatory | Identifies whether or not any active payload loops were detected in the interval which this entry represents. |
| 1.3.6.1.4.1.498.6.10.5.2 | Tablemp7001OutboundANSIperfTable | not-accessible | mandatory | The GDC ANSI Performance table. Information in the entries of this table support the ANSI Scheduled Performance Reports. Entries supply information for outboun… |
| 1.3.6.1.4.1.498.6.10.5.2.1 | Rowmp7001OutboundANSIperfEntry | not-accessible | mandatory | The GDC ANSI Performance table entry. The information in this entry presents one of the 4 second periods performance data in the outbound direction. |
| 1.3.6.1.4.1.498.6.10.5.2.1.1 | Columnmp7001OutboundANSIperfIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.5.2.1.2 | Columnmp7001OutboundANSIseconds | read-only | mandatory | Identifies the reporting interval. This has the value 1 to 4 supporting up to the last 4 seconds of performance data. |
| 1.3.6.1.4.1.498.6.10.5.2.1.3 | Columnmp7001OutboundANSICRCerrorEvents | read-only | mandatory | Identifies the magnitude of the error events in the interval which this entry represents. |
| 1.3.6.1.4.1.498.6.10.5.2.1.4 | Columnmp7001OutboundANSIsevereErrors | read-only | mandatory | Identifies whether or not any severe errors were detected in the interval which this entry represents. |
| 1.3.6.1.4.1.498.6.10.5.2.1.5 | Columnmp7001OutboundANSIframeErrors | read-only | mandatory | Identifies whether or not any framing errors were detected in the interval which this entry represents. |
| 1.3.6.1.4.1.498.6.10.5.2.1.6 | Columnmp7001OutboundANSIcodeViolations | read-only | mandatory | Identifies whether or not any code violations were detected in the interval which this entry represents. |
| 1.3.6.1.4.1.498.6.10.5.2.1.7 | Columnmp7001OutboundANSIcontrolledSlips | read-only | mandatory | Identifies whether or not any controlled slips were detected in the interval which this entry represents. |
| 1.3.6.1.4.1.498.6.10.5.2.1.8 | Columnmp7001OutboundANSIactivePayloadLoops | read-only | mandatory | Identifies whether or not any active payload loops were detected in the interval which this entry represents. |
| 1.3.6.1.4.1.498.6.10.5.3 | Tablemp7001CurrentTable | not-accessible | mandatory | The mp7001 Current table. This table supplements the entries in the DS1 AT&T performance table of the DS1 MIB defined in RFC1406. |
| 1.3.6.1.4.1.498.6.10.5.3.1 | Rowmp7001CurrentEntry | not-accessible | mandatory | An entry in the mp7001 Current table. |
| 1.3.6.1.4.1.498.6.10.5.3.1.1 | Columnmp7001CurrentIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.5.3.1.2 | Columnmp7001CurrentStat | read-only | mandatory | Returns a bitwise snapshot of the current statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit … |
| 1.3.6.1.4.1.498.6.10.5.4 | Tablemp7001IntervalTable | not-accessible | mandatory | The mp7001 Interval table. This table supplements the entries in the DS1 AT&T performance table of the DS1 MIB defined in RFC1406. |
| 1.3.6.1.4.1.498.6.10.5.4.1 | Rowmp7001IntervalEntry | not-accessible | mandatory | An entry in the DS1 Interval table. |
| 1.3.6.1.4.1.498.6.10.5.4.1.1 | Columnmp7001IntervalIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.5.4.1.2 | Columnmp7001IntervalNumber | read-only | mandatory | A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that … |
| 1.3.6.1.4.1.498.6.10.5.4.1.3 | Columnmp7001IntervalStat | read-only | mandatory | Returns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit… |
| 1.3.6.1.4.1.498.6.10.5.5 | Tablemp7001TotalTable | not-accessible | mandatory | The DS1 Total table. 24 hour interval. This table supplements the entries in the DS1 AT&T performance table of the DS1 MIB defined in RFC1406. |
| 1.3.6.1.4.1.498.6.10.5.5.1 | Rowmp7001TotalEntry | not-accessible | mandatory | An entry in the DS1 Total table. |
| 1.3.6.1.4.1.498.6.10.5.5.1.1 | Columnmp7001TotalIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.5.5.1.2 | Columnmp7001TotalStat | read-only | mandatory | Returns a bitwise snapshot of the total statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit 2 … |
| 1.3.6.1.4.1.498.6.10.6 | Nodemp7001AlarmConfig | |||
| 1.3.6.1.4.1.498.6.10.6.1 | Tablemp7001NearEndAlarmConfigTable | not-accessible | mandatory | This table contains entries that configure Near End Alarm reporting. |
| 1.3.6.1.4.1.498.6.10.6.1.1 | Rowmp7001NearEndAlarmConfigEntry | not-accessible | mandatory | An entry in the MP7001 Alarm Configuration table. |
| 1.3.6.1.4.1.498.6.10.6.1.1.1 | Columnmp7001NearEndAlarmConfigIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.6.1.1.2 | Columnmp7001NearEndAlarmConfigIdentifier | read-only | mandatory | The unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) do… |
| 1.3.6.1.4.1.498.6.10.6.1.1.3 | Columnmp7001NearEndAlarmCountWindow | read-write | mandatory | This variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Defa… |
| 1.3.6.1.4.1.498.6.10.6.1.1.4 | Columnmp7001NearEndAlarmCountThreshold | read-write | mandatory | This function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given t… |
| 1.3.6.1.4.1.498.6.10.6.2 | Tablemp7001LocalAlarmConfigTable | not-accessible | mandatory | The mp7001LocalAlarmConfigTable contains entries that configure alarm reporting to the alarm card. |
| 1.3.6.1.4.1.498.6.10.6.2.1 | Rowmp7001LocalAlarmConfigEntry | not-accessible | mandatory | An entry in the GDC Local Alarm Configuration table. |
| 1.3.6.1.4.1.498.6.10.6.2.1.1 | Columnmp7001LocalAlarmConfigIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.6.2.1.2 | Columnmp7001LOSLocal | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.6.10.6.2.1.3 | Columnmp7001LOFLocal | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.6.10.6.2.1.4 | Columnmp7001AISLocal | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.6.10.6.2.1.5 | Columnmp7001RxYELLOWLocal | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.6.10.6.2.1.6 | Columnmp7001BPVLocal | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.6.10.6.2.1.7 | Columnmp7001CRCLocal | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.6.10.6.2.1.8 | Columnmp7001UnSigStateLocal | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.6.10.6.2.1.9 | Columnmp7001TiminglossLocal | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.6.10.6.2.1.10 | Columnmp7001ESLocal | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.6.10.6.2.1.11 | Columnmp7001BESLocal | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.6.10.6.2.1.12 | Columnmp7001SESLocal | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.6.10.6.2.1.13 | Columnmp7001UASLocal | read-write | mandatory | Disables or enables the alarm on the Major buss or Minor buss. |
| 1.3.6.1.4.1.498.6.10.7 | Nodemp7001SysConfig | |||
| 1.3.6.1.4.1.498.6.10.7.1 | Tablemp7001SysTimingTable | not-accessible | mandatory | The GDC System Timing table. |
| 1.3.6.1.4.1.498.6.10.7.1.1 | Rowmp7001SysTimingEntry | not-accessible | mandatory | The GDC Configuration table entry. |
| 1.3.6.1.4.1.498.6.10.7.1.1.1 | Columnmp7001SysTimingIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.7.1.1.2 | Columnmp7001SysTimingGen | read-write | mandatory | Selects if the unit provides system timing. none(1) - does not provide Timing Generator primary(2) - unit is primary Timing Generator for the shelf. secondary(… |
| 1.3.6.1.4.1.498.6.10.7.2 | Tablemp7001HighwayAssignTable | not-accessible | mandatory | The GDC Highway/Timeslot Assignment Table. |
| 1.3.6.1.4.1.498.6.10.7.2.1 | Rowmp7001HighwayAssignEntry | not-accessible | mandatory | The GDC T1 Highway Assign table entry. |
| 1.3.6.1.4.1.498.6.10.7.2.1.1 | Columnmp7001HighwayAssignIndex | read-only | mandatory | Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical sh… |
| 1.3.6.1.4.1.498.6.10.7.2.1.2 | Columnmp7001StartTimeSlot | read-write | mandatory | Starting time slot of the bundle. If only 1 bundle is being assigned, or the first of 2 is being assigned, it must start at 1. The second of 2 must start at th… |
| 1.3.6.1.4.1.498.6.10.7.2.1.3 | Columnmp7001NumberOfTimeSlots | read-write | mandatory | Number of time slots assigned to the bundle. |
| 1.3.6.1.4.1.498.6.10.7.2.1.4 | Columnmp7001BundleDestination | read-write | mandatory | Defines the destination of the bundle. |
| 1.3.6.1.4.1.498.6.10.7.2.1.5 | Columnmp7001ExecuteAssign | read-write | mandatory | Causes the MP7001 to execute configuration of the assigned highway configuration. This object should be sent in a separate PDU after acknowlegement of the assi… |
| 1.3.6.1.4.1.498.6.10.8 | Nodemp7001Alarms | |||
| 1.3.6.1.4.1.498.6.10.8.1 | Nodemp7001NoResponseAlm | |||
| 1.3.6.1.4.1.498.6.10.8.2 | Nodemp7001DiagRxErrAlm | |||
| 1.3.6.1.4.1.498.6.10.8.3 | Nodemp7001PowerUpAlm | |||
| 1.3.6.1.4.1.498.6.10.8.4 | Nodemp7001NvRamCorrupt | |||
| 1.3.6.1.4.1.498.6.10.8.5 | Nodemp7001UnitFailure | |||
| 1.3.6.1.4.1.498.6.10.8.6 | Nodemp7001LossOfSignal | |||
| 1.3.6.1.4.1.498.6.10.8.7 | Nodemp7001LossOfFrame | |||
| 1.3.6.1.4.1.498.6.10.8.8 | Nodemp7001Ais | |||
| 1.3.6.1.4.1.498.6.10.8.9 | Nodemp7001YELLOW | |||
| 1.3.6.1.4.1.498.6.10.8.10 | Nodemp7001BipolarViolation | |||
| 1.3.6.1.4.1.498.6.10.8.11 | Nodemp7001CRC | |||
| 1.3.6.1.4.1.498.6.10.8.12 | Nodemp7001UnSigState | |||
| 1.3.6.1.4.1.498.6.10.8.13 | Nodemp7001TimingLoss | |||
| 1.3.6.1.4.1.498.6.10.8.14 | Nodemp7001ES | |||
| 1.3.6.1.4.1.498.6.10.8.15 | Nodemp7001BES | |||
| 1.3.6.1.4.1.498.6.10.8.16 | Nodemp7001SES | |||
| 1.3.6.1.4.1.498.6.10.8.17 | Nodemp7001UAS | |||
| 1.3.6.1.4.1.498.6.10.8.18 | Nodemp7001ControlSlips | |||
| 1.3.6.1.4.1.498.6.10.8.19 | Nodemp7001UnsolicitedTest |