MIB Viewer

GDCSC611-MIB

89 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.498Nodegdc
1.3.6.1.4.1.498.12Nodebql2
1.3.6.1.4.1.498.12.2Nodebql611
1.3.6.1.4.1.498.12.2.1Scalarbql611MIBVersionread-onlymandatoryThe version number of the MIB, to allow products to know which MIB is being supported. The version number will be x.yzT where x is a major revision (1-9), y is…
1.3.6.1.4.1.498.12.2.2Tablebql611WhatAreYouTablenot-accessiblemandatoryThe GDC SC611 and DC621 What Are You Table.
1.3.6.1.4.1.498.12.2.2.1Rowbql611WhatAreYouEntrynot-accessiblemandatoryAn entry in the GDC SC611 What Are You table.
1.3.6.1.4.1.498.12.2.2.1.1Columnbql611WhatAreYouIndexread-onlymandatoryThis object is the identifier of the SC611/DC621 What Are You table.
1.3.6.1.4.1.498.12.2.2.1.2Columnbql611BaseCardTyperead-onlymandatoryThis function returns the value the Base Card Type.
1.3.6.1.4.1.498.12.2.2.1.3Columnbql611OptionCardread-onlymandatoryThis indicates whether the option card is installed or not on the DC621.
1.3.6.1.4.1.498.12.2.2.1.4Columnbql611DTECardTyperead-onlymandatoryThis object is the DTE plug-in card type. This variable is used for a SC611 or DC621.
1.3.6.1.4.1.498.12.2.2.1.5Columnbql611CodeRevread-onlymandatoryThis function returns the firmware code level. Example A- ,B-
1.3.6.1.4.1.498.12.2.2.1.6Columnbql611AlarmStatusread-onlymandatoryThe current alarms of the unit without the alarm masks.
1.3.6.1.4.1.498.12.2.3Tablebql611ConfigTablenot-accessiblemandatoryThe GDC SC611, DC621 2B1Q configuration table.
1.3.6.1.4.1.498.12.2.3.1Rowbql611ConfigEntrynot-accessiblemandatoryA listing of GDC 2B1Q SC611/DC621 options.
1.3.6.1.4.1.498.12.2.3.1.1Columnbql611ConfigIndexread-onlymandatoryA unique index for the Configuration Table.
1.3.6.1.4.1.498.12.2.3.1.2Columnbql611DteRateread-writemandatoryObject to select the DTE rate for the SC611 or DC621.
1.3.6.1.4.1.498.12.2.3.1.3Columnbql611RateAdaptionread-writemandatoryObject to select the DTE Rate Adaption for the SC611 or DC621.
1.3.6.1.4.1.498.12.2.3.1.4Columnbql611DteOperationread-writemandatoryObject to select the DTE Operation for the SC611 or DC621.
1.3.6.1.4.1.498.12.2.3.1.5Columnbql611TxClkSourceread-writemandatoryObject to select the Transmit Clock Source for the SC611 ONLY.
1.3.6.1.4.1.498.12.2.3.1.6Columnbql611WordLengthread-writemandatoryObject to select the Word Length for the SC611 or DC621 when selected for async mode.
1.3.6.1.4.1.498.12.2.3.1.7Columnbql611OverSpeedread-writemandatoryObject to select the Over Speed for the SC611 or DC621.
1.3.6.1.4.1.498.12.2.3.1.8Columnbql611RTSread-writemandatoryObject to select RTS for SC611 and DC621 only.
1.3.6.1.4.1.498.12.2.3.1.9Columnbql611RTSCTSDelayread-writemandatoryObject to select RTS CTS Delay for SC611 and DC621.
1.3.6.1.4.1.498.12.2.3.1.10Columnbql611DCDread-writemandatoryObject to select DCD for SC611 and DC621.
1.3.6.1.4.1.498.12.2.3.1.11Columnbql611RDLread-writemandatoryObject to select the RDL respond for SC611 and DC621.
1.3.6.1.4.1.498.12.2.3.1.12Columnbql611RDLMethodread-writemandatoryObject to select RDL Method for SC611 and DC621. SC611 Valid Choices DC621 Valid Choices =================== =================== V54 V54 EOC PN127
1.3.6.1.4.1.498.12.2.3.1.13Columnbql611RDLTimeoutread-writemandatoryObject to select RDL Timeout for SC611 or DC621.
1.3.6.1.4.1.498.12.2.3.1.14Columnbql611TestPatternread-writemandatoryObject to Test Pattern for SC611 and DC621.
1.3.6.1.4.1.498.12.2.4Tablebql611DiagnosticTablenot-accessiblemandatoryThe GDC SC611/DC621 diagnostics table.
1.3.6.1.4.1.498.12.2.4.1Rowbql611DiagnosticEntrynot-accessiblemandatoryA listing of GDC SC611/DC621 diagnostic tests
1.3.6.1.4.1.498.12.2.4.1.1Columnbql611DiagnosticIndexread-onlymandatoryA unique index for the Diagnostic Table.
1.3.6.1.4.1.498.12.2.4.1.2Columnbql611DiagnosticTestread-writemandatoryThis function selects or reads the test. 0 = no test currently operating 1 = remote loopback test 2 = channel loopback test 4 = data loopback test 8 = selftest…
1.3.6.1.4.1.498.12.2.4.1.3Columnbql611DiagnosticActiveread-onlymandatoryThis function represents the test condition.
1.3.6.1.4.1.498.12.2.4.1.4Columnbql611DiagnosticResultsread-onlymandatoryThis function reads the self test results in bit errors.
1.3.6.1.4.1.498.12.2.4.1.5Columnbql611DiagnosticResetErrorCountread-writemandatoryObject to reset selftest error count during diagnostic self testing for SC611 and DC621.
1.3.6.1.4.1.498.12.2.5Tablebql611ControlTablenot-accessiblemandatoryThe GDC SC611 and DC621 Control Table.
1.3.6.1.4.1.498.12.2.5.1Rowbql611ControlEntrynot-accessiblemandatoryAn entry in the GDC SC611/DC621 Control table.
1.3.6.1.4.1.498.12.2.5.1.1Columnbql611ControlIndexread-onlymandatoryThis object is the identifier of the SC611/DC621 Control table.
1.3.6.1.4.1.498.12.2.5.1.2Columnbql611SoftResetread-writemandatoryForces a soft reset on the network element. The reset selection is write only. The normal selection is read only.
1.3.6.1.4.1.498.12.2.5.1.3Columnbql611EraseConfigread-writemandatoryForces an erase of the stored configuration in the network element. The erase selection is write only. The normal selection is read only.
1.3.6.1.4.1.498.12.2.5.1.4Columnbql611FrontPanelread-writemandatoryObject used to enable or disable the units front panel switches.
1.3.6.1.4.1.498.12.2.5.1.5Columnbql611LEDStatusread-onlymandatoryThe GDC SC611 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - not used 1.5 - not used 1.4 - test mode 1.3 - alarm …
1.3.6.1.4.1.498.12.2.5.1.6Columnbql621LEDStatusread-onlymandatoryThe GDC DC621 front panel LED Status. A value of 1 means on, 0 is off. byte 1 bit 7 (1.7) - not used 1.6 - test mode 1.5 - sync 1.4 - request to send 1.3 - cle…
1.3.6.1.4.1.498.12.2.6Tablebql611CurrentTablenot-accessiblemandatoryThe SC611/DC621 Current table.
1.3.6.1.4.1.498.12.2.6.1Rowbql611CurrentEntrynot-accessiblemandatoryAn entry in the SC611/DC621 Current table.
1.3.6.1.4.1.498.12.2.6.1.1Columnbql611CurrentIndexread-onlymandatoryThe index value which uniquely identifies the SC611 interface to which this entry is applicable.
1.3.6.1.4.1.498.12.2.6.1.2Columnbql611CurrentStatsread-onlymandatoryThe number of Errored Seconds, Severely Errored Seconds & Unavailable Errored Seconds encountered by an ISDN interface in the current 15 minute interval.
1.3.6.1.4.1.498.12.2.8Tablebql611IntervalTablenot-accessiblemandatoryThe SC611/DC621 Interval table.
1.3.6.1.4.1.498.12.2.8.1Rowbql611IntervalEntrynot-accessiblemandatoryAn entry in the SC611/DC621 Interval table.
1.3.6.1.4.1.498.12.2.8.1.1Columnbql611IntervalIndexread-onlymandatoryThe index value which uniquely identifies the ISDN interface to which this entry is applicable.
1.3.6.1.4.1.498.12.2.8.1.2Columnbql611IntervalNumberread-onlymandatoryA number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minute inter- val (assuming that…
1.3.6.1.4.1.498.12.2.8.1.3Columnbql611IntervalStatsread-onlymandatoryThe number of Errored Seconds, Severely Errored Seconds and Unavailable Errored Seconds encountered by a DS1 interface in one of the previous 96, individual 15…
1.3.6.1.4.1.498.12.2.9Tablebql611TotalTablenot-accessiblemandatoryThe SC611/DC621 Total table. 24 hour interval.
1.3.6.1.4.1.498.12.2.9.1Rowbql611TotalEntrynot-accessiblemandatoryAn entry in the SC611/DC621 Total table.
1.3.6.1.4.1.498.12.2.9.1.1Columnbql611TotalIndexread-onlymandatoryThe index value which uniquely identifies the ISDN interface to which this entry is applicable.
1.3.6.1.4.1.498.12.2.9.1.2Columnbql611TotalStatsread-onlymandatoryThe number of Errored Seconds,Severely Errored Seconds & Unavailable Errored Seconds encountered by an ISDN interface in the previous 24 hour interval.
1.3.6.1.4.1.498.12.2.10Tablebql611IntervalMaintenanceTablenot-accessiblemandatoryThe SC611, DC621 Loop Interval Maintenance table.
1.3.6.1.4.1.498.12.2.10.1Rowbql611IntervalMaintenanceEntrynot-accessiblemandatoryThe SC611, DC621 Interval Maintenance table entry.
1.3.6.1.4.1.498.12.2.10.1.1Columnbql611IntervalMaintenanceIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a SCinstance which defines the slot, line, drop…
1.3.6.1.4.1.498.12.2.10.1.2Columnbql611ResetIntervalsread-writemandatoryThis variable is used to reset Loop performance intervals. When it is set to reset, the Loop performance tables are reset to zero.
1.3.6.1.4.1.498.12.2.10.1.3Columnbql611NumberofValidIntervalsread-onlymandatoryThis variable is used to read the number of intervals collected. Each interval is an increment of 15 minutes.
1.3.6.1.4.1.498.12.2.10.1.4Columnbql611ResetMajorAlarmread-writemandatoryThis variable is used to reset alarm per Loop basis.
1.3.6.1.4.1.498.12.2.10.1.5Columnbql611ResetMinorAlarmread-writemandatoryThis variable is used to reset alarm per Loop basis.
1.3.6.1.4.1.498.12.3Nodebql621
1.3.6.1.4.1.498.12.9Nodebql611Alarm
1.3.6.1.4.1.498.12.9.1Nodebql611AlarmData
1.3.6.1.4.1.498.12.9.1.1Nodebql611NoResponseAlm
1.3.6.1.4.1.498.12.9.1.2Nodebql611DiagRxErrAlm
1.3.6.1.4.1.498.12.9.1.3Nodebql611PowerUpAlm
1.3.6.1.4.1.498.12.9.1.4Nodebql611OutofSyncAlm
1.3.6.1.4.1.498.12.9.1.5Nodebql611TxClkOutOfToleranceAlm
1.3.6.1.4.1.498.12.9.1.6Nodebql611ExtClkAbsentAlm
1.3.6.1.4.1.498.12.9.1.7Nodebql611SealingCurrentNoContinuityAlm
1.3.6.1.4.1.498.12.9.1.8Nodebql611DtrNotPresentAlm
1.3.6.1.4.1.498.12.9.1.9Nodebql611MajorAlarmBERAlm
1.3.6.1.4.1.498.12.9.1.10Nodebql611MinorAlarmBERAlm
1.3.6.1.4.1.498.12.9.2Tablebql611AlarmConfigTablenot-accessiblemandatoryThe bql611AlarmConfigTable contains entries that configure alarm reporting. The structure of the table is such that alarm configuration is supported on a unit …
1.3.6.1.4.1.498.12.9.2.1Rowbql611AlarmConfigEntrynot-accessiblemandatoryAn entry in the bql611AlarmConfigTable table.
1.3.6.1.4.1.498.12.9.2.1.1Columnbql611AlarmConfigIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable.
1.3.6.1.4.1.498.12.9.2.1.2Columnbql611AlarmConfigIdentifierread-onlymandatoryThe unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) do…
1.3.6.1.4.1.498.12.9.2.1.3Columnbql611AlarmThresholdread-writemandatoryThis function sets/reads the Major or Minor BER alarm threshold criteria for a SC611 or DC621.
1.3.6.1.4.1.498.12.11Nodebql621Alarm
1.3.6.1.4.1.498.12.11.1Nodebql621AlarmData
1.3.6.1.4.1.498.12.11.1.1Nodebql621NoResponseAlm
1.3.6.1.4.1.498.12.11.1.2Nodebql621DiagRxErrAlm
1.3.6.1.4.1.498.12.11.1.3Nodebql621PowerUpAlm
1.3.6.1.4.1.498.12.11.1.4Nodebql621DtrNotPresentAlm
1.3.6.1.4.1.498.12.11.1.5Nodebql621MajorAlarmBERAlm
1.3.6.1.4.1.498.12.11.1.6Nodebql621MinorAlarmBERAlm