MIB Viewer

GDCUAS7624-MIB

111 objects
No module-level DESCRIPTION found.
OIDNameAccessStatusDescription
1.3.6.1.4.1.498Nodegdc
1.3.6.1.4.1.498.18Nodeniudiu
1.3.6.1.4.1.498.18.1Nodeuas7624System
1.3.6.1.4.1.498.18.1.1Nodeuas7624Version
1.3.6.1.4.1.498.18.1.1.1Scalaruas7624MIBversionread-onlymandatoryIdentifies the version of the MIB. The format of the version is x.yzT, where 'x' identifies the major revision number, 'y' identifies the minor revision number…
1.3.6.1.4.1.498.18.1.1.2Tableuas7624VersionTablenot-accessiblemandatoryThe 7624 version table
1.3.6.1.4.1.498.18.1.1.2.1Rowuas7624VersionEntrynot-accessiblemandatoryAn entry in the GDC uas7624System Version Table.
1.3.6.1.4.1.498.18.1.1.2.1.1Columnuas7624VersionIndexread-onlymandatoryInteger value which uniquely identifies the uas7624 to which this entry is applicable. For entire table: SCinstance: [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.1.2.1.2Columnuas7624FirmwareRevread-onlymandatory
1.3.6.1.4.1.498.18.1.1.2.1.3Columnuas7624CardTyperead-onlymandatoryThis variable is used to determine the type of card family installed ex. uas7624.
1.3.6.1.4.1.498.18.1.1.2.1.4Columnuas7624BootRevread-onlymandatory
1.3.6.1.4.1.498.18.1.2Nodeuas7624Maintenance
1.3.6.1.4.1.498.18.1.2.1Tableuas7624MaintenanceTablenot-accessiblemandatoryThe table describes the maintenance objects for uas7624.
1.3.6.1.4.1.498.18.1.2.1.1Rowuas7624MaintenanceEntrynot-accessiblemandatoryAn entry in the GDC 7624 Maintenance Table.
1.3.6.1.4.1.498.18.1.2.1.1.1Columnuas7624MaintenanceLineIndexread-onlymandatoryInteger value which uniquely identifies the uas7624 to which this entry is applicable. See DESCRIPTION's below for ranges.
1.3.6.1.4.1.498.18.1.2.1.1.2Columnuas7624SoftResetread-writemandatorySupports the action of soft resetting the unit. When this object is set to reset(2), then the unit performs a soft reset, whose meaning is specific to the type…
1.3.6.1.4.1.498.18.1.2.1.1.3Columnuas7624DefaultInitread-writemandatoryThis is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefault(2) the unit will perform a r…
1.3.6.1.4.1.498.18.1.2.1.1.4Columnuas7624ResetMajorAlarmread-writemandatoryThis variable is used. SCinstance: [L]ine=1-4 [i]nterface=1-3
1.3.6.1.4.1.498.18.1.2.1.1.5Columnuas7624ResetMinorAlarmread-writemandatoryThis variable is used. SCinstance: [L]ine=1-4 [i]nterface=1-3
1.3.6.1.4.1.498.18.1.2.1.1.6Columnuas7624ResetStatisticsread-writemandatoryThis variable is used to reset the performance intervals. When it is set to reset, the performance tables and uas7624Valid intervals are reset to zero. The val…
1.3.6.1.4.1.498.18.1.2.1.1.7Columnuas7624StatLastInitializedread-onlymandatoryThe elapsed time since the statistics were last initialized. This will be zero'd when uas7624ResetStatistics is reset(2). SCinstance: [L]ine=1-4 [i]nterface=1-…
1.3.6.1.4.1.498.18.1.2.1.1.8Columnuas7624ValidIntervalsread-onlymandatoryThe number of previous intervals for which valid data was collected. The value will be 96 for the T1 interface and 16 for the loop interface unless the interfa…
1.3.6.1.4.1.498.18.1.2.1.1.9Columnuas7624SysUpTimeread-onlymandatoryThis variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to the sysUpTime referenced in MI…
1.3.6.1.4.1.498.18.1.2.1.1.10Columnuas7624LedStatusread-onlymandatoryReturns a bitwise snapshot of the front panel LED state. based on the Line: For SCinstance: [L]ine=1-4 [i]nterface=0 key 01 = SOLID GREEN Good Condition and in…
1.3.6.1.4.1.498.18.1.2.1.1.11Columnuas7624AlarmStatusread-onlymandatoryReturns a bit-wise Status of alarms with both masked and unmasked. For SCinstance: [L]ine=1-4 [i]nterface=0 1.7 - f/u 1.6 - Power-up 1.5 - f/u 1.4 - Loop 1 OOS…
1.3.6.1.4.1.498.18.1.2.1.1.12Columnuas7624LoopStateread-writemandatoryA setting of inhibit(1) stops operation on the loop and a setting of enable(2) starts operation on the loop. SCinstance: [L]ine=1-4 [i]nterface=1-3
1.3.6.1.4.1.498.18.1.2.1.1.13Columnuas7624ConfigModeread-onlymandatoryThis variable is used to report the mode, either soft or hard, of the the uas7624. If the unit is in hard mode then the options in the uas7624ConfigTable are r…
1.3.6.1.4.1.498.18.1.3Nodeuas7624Configuration
1.3.6.1.4.1.498.18.1.3.1Tableuas7624ConfigTablenot-accessiblemandatoryThe GDC Configuration table.
1.3.6.1.4.1.498.18.1.3.1.1Rowuas7624ConfigEntrynot-accessiblemandatoryThe GDC Configuration table entry.
1.3.6.1.4.1.498.18.1.3.1.1.1Columnuas7624ConfigIndexread-onlymandatoryInteger value which uniquely identifies the uas7624 to which this entry is applicable. For entire table: SCinstance: [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.3.1.1.2Columnuas7624NetworkInterfaceTyperead-writemandatorySets the transmit range to DSX-1 short or DS-1 long
1.3.6.1.4.1.498.18.1.3.1.1.3Columnuas7624TransmitClockSourceread-writemandatorySets the transmit clock source.
1.3.6.1.4.1.498.18.1.3.1.1.4Columnuas7624PreEqualizationread-writemandatoryPre-Equalization distance
1.3.6.1.4.1.498.18.1.3.1.1.5Columnuas7624Framingread-writemandatorySet the framing for the interface. Abbreviations are as follows: eSF - Extended Super Frame d4 - Super Frame
1.3.6.1.4.1.498.18.1.3.1.1.6Columnuas7624LineCodingread-writemandatorySets the line coding for the interface.
1.3.6.1.4.1.498.18.1.3.1.1.7Columnuas7624LineBuildoutread-writemandatorySets the line build out for the T1 interface.
1.3.6.1.4.1.498.18.1.3.1.1.8Columnuas7624FDLModeread-writemandatorySets the Facility Data Link Mode.
1.3.6.1.4.1.498.18.1.3.1.1.9Columnuas7624Loopbackread-writemandatorySets the loopback type
1.3.6.1.4.1.498.18.1.3.1.1.10Columnuas7624AISLoopdownread-writemandatorySets AIS unloop time where 4 = inhibit, 5 thru 60 = number of seconds
1.3.6.1.4.1.498.18.1.3.1.1.11Columnuas7624LineBuildoutModeread-writemandatorySets the line build out mode for the T1 interface.
1.3.6.1.4.1.498.18.1.3.1.1.12Columnuas7624FramingModeread-writemandatorySet the framing mode.
1.3.6.1.4.1.498.18.1.4Nodeuas7624Diagnostics
1.3.6.1.4.1.498.18.1.4.1Tableuas7624DiagTablenot-accessiblemandatoryThe GDC 7624 Diagnostics table. Information in the entries of this table support diagnostics testing, both active testing via patterns, and passive testing via…
1.3.6.1.4.1.498.18.1.4.1.1Rowuas7624DiagEntrynot-accessiblemandatoryThe GDC 7624 Diagnostics table entry.
1.3.6.1.4.1.498.18.1.4.1.1.1Columnuas7624DiagIndexread-onlymandatoryInteger value which uniquely identifies the uas7624 to which this entry is applicable. See DESCRIPTION's below for ranges.
1.3.6.1.4.1.498.18.1.4.1.1.2Columnuas7624DiagConfigread-writemandatorySelects test to run. (1) stops test. SCinstance: stopTest(1) [L]ine=1-5 [i]nterface=0-3 lineLoopback(2) [L]ine=5 [i]nterface=0 payloadLoopback(3) [L]ine=5 [i]n…
1.3.6.1.4.1.498.18.1.4.1.1.3Columnuas7624T1TestLimitread-writemandatorySelects the duration to run a T1 diagnostic test. The value(1) noLimit signifies that the test should run indefinitely until explicitly terminated. SCinstance:…
1.3.6.1.4.1.498.18.1.4.1.1.4Columnuas7624T1TestExecutionStatusread-onlymandatoryThis variable reports the status of a T1 test. notInTest(1) indicates a test is not running. testInProgress(2) indicates that a test is currently running. test…
1.3.6.1.4.1.498.18.1.4.1.1.5Columnuas7624T1TestExceptionsread-onlymandatoryIndicates T1 test exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. This sum initially take …
1.3.6.1.4.1.498.18.1.4.1.1.6Columnuas7624TestResultsread-onlymandatoryThe results of the last T1 diagnostic test. This can be the current test running or the last completed test. Note that the interpretation of these results may …
1.3.6.1.4.1.498.18.1.4.1.1.7Columnuas7624ResetTestResultsread-writemandatoryResets the diagnostic T1 or Loop error count. SCinstance: [L]ine=1-4 [i]nterface=1-3 [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.5Nodeuas7624Performance
1.3.6.1.4.1.498.18.1.5.3Tableuas7624CurrentTablenot-accessiblemandatoryThe uas7624 Current table contains various statistics being collected for the current 15 minute interval.
1.3.6.1.4.1.498.18.1.5.3.1Rowuas7624CurrentEntrynot-accessiblemandatoryAn entry in the uas7624 Current table.
1.3.6.1.4.1.498.18.1.5.3.1.1Columnuas7624CurrentIndexread-onlymandatoryInteger value which uniquely identifies the uas7624 to which this entry is applicable. For this table: SCinstance: [L]ine=1-4 [i]nterface=1-3 [L]ine=5 [i]nterf…
1.3.6.1.4.1.498.18.1.5.3.1.2Columnuas7624CurrentStatread-onlymandatoryReturns a bitwise snapshot of the interval statistics. for [L]ine=1-4 [i]nterface=1-3 (SIZE (10)) Octet 1 bit 7 - not used bit 6 - future use bit 5 - future us…
1.3.6.1.4.1.498.18.1.5.4Tableuas7624IntervalTablenot-accessiblemandatoryThe uas7624 Interval table contains various statistics collected by each Interface over the previous 24 hours of operation. For this table: SCinstance: [L]ine=…
1.3.6.1.4.1.498.18.1.5.4.1Rowuas7624IntervalEntrynot-accessiblemandatoryAn entry in the DS1 Interval table.
1.3.6.1.4.1.498.18.1.5.4.1.1Columnuas7624IntervalIndexread-onlymandatoryInteger value which uniquely identifies the uas7624 to which this entry is applicable.
1.3.6.1.4.1.498.18.1.5.4.1.2Columnuas7624IntervalNumberread-onlymandatoryFor the T1 interface: A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes in…
1.3.6.1.4.1.498.18.1.5.4.1.3Columnuas7624IntervalStatread-onlymandatoryReturns a bitwise snapshot of the interval statistics. for [L]ine=1-4 [i]nterface=1-3 (SIZE (11)) Octet 1 bit 7 - not used bit 6 - future use bit 5 - future us…
1.3.6.1.4.1.498.18.1.5.5Tableuas7624TotalTablenot-accessiblemandatoryThe DS1 Total table. 24 hour interval.
1.3.6.1.4.1.498.18.1.5.5.1Rowuas7624TotalEntrynot-accessiblemandatoryAn entry in the DS1 Total table.
1.3.6.1.4.1.498.18.1.5.5.1.1Columnuas7624TotalIndexread-onlymandatoryInteger value which uniquely identifies the uas7624 to which this entry is applicable. For this table: SCinstance: [L]ine=1-4 [i]nterface=1-3 [L]ine=5 [i]nterf…
1.3.6.1.4.1.498.18.1.5.5.1.2Columnuas7624TotalStatread-onlymandatoryReturns a bitwise snapshot of the interval statistics. for [L]ine=1-4 [i]nterface=1-3 (SIZE (14)) Octet 1 bit 7 - not used bit 6 - future use bit 5 - future us…
1.3.6.1.4.1.498.18.1.5.6Tableuas7624Recent24HrTablenot-accessiblemandatoryThe Recent24Hr table. 4 hour interval
1.3.6.1.4.1.498.18.1.5.6.1Rowuas7624Recent24HrEntrynot-accessiblemandatoryAn entry in the Recent24Hr table.
1.3.6.1.4.1.498.18.1.5.6.1.1Columnuas7624Recent24HrIndexread-onlymandatoryThe index value which uniquely identifies the interface to which this entry is applicable. This has the form of a For this table: SCinstance: [L]ine=1-4 [i]nte…
1.3.6.1.4.1.498.18.1.5.6.1.2Columnuas7624Recent24HrStatread-onlymandatoryReturns a bitwise snapshot of the interval statistics. Octet 1 bit 7 - not used bit 6 - future use bit 5 - future use bit 4 - future use bit 3 - future use bit…
1.3.6.1.4.1.498.18.1.6Nodeuas7624AlarmConfig
1.3.6.1.4.1.498.18.1.6.1Tableuas7624AlarmConfigTablenot-accessiblemandatoryThis table contains entries that configure Alarm reporting.
1.3.6.1.4.1.498.18.1.6.1.1Rowuas7624AlarmConfigEntrynot-accessiblemandatoryAn entry in the uas7624 Alarm Configuration table.
1.3.6.1.4.1.498.18.1.6.1.1.1Columnuas7624AlarmConfigIndexread-onlymandatoryInteger value which uniquely identifies the uas7624 to which this entry is applicable. For this table: SCinstance: [L]ine=1-4 [i]nterface=1-3 [L]ine=5 [i]nterf…
1.3.6.1.4.1.498.18.1.6.1.1.2Columnuas7624AlarmConfigIdentifierread-onlymandatoryThe unique alarm identifier assigned to this alarm type. The format of this identifier is an OBJECT IDENTIFIER that has the following format: {iso(1) org(3) do…
1.3.6.1.4.1.498.18.1.6.1.1.3Columnuas7624AlarmCountWindowread-writemandatoryThis variable sets/reads the alarm window. This window is used with the alarm threshold to determine how long the alarm should be active before reporting. Defa…
1.3.6.1.4.1.498.18.1.6.1.1.4Columnuas7624AlarmCountThresholdread-writemandatoryThis function sets/reads the alarm threshold criteria. This threshold is used along with the the alarm window to determine the number of instances in a given t…
1.3.6.1.4.1.498.18.1.6.2Tableuas7624LocalAlarmConfigTablenot-accessiblemandatoryThe uas7624LocalAlarmConfigTable contains entries that configure alarm reporting to the alarm card.
1.3.6.1.4.1.498.18.1.6.2.1Rowuas7624LocalAlarmConfigEntrynot-accessiblemandatoryAn entry in the GDC Local Alarm Configuration table.
1.3.6.1.4.1.498.18.1.6.2.1.1Columnuas7624LocalAlarmConfigIndexread-onlymandatoryInteger value which uniquely identifies the uas7624 to which this entry is applicable. For this table: See DESCRIPTION's below for ranges.
1.3.6.1.4.1.498.18.1.6.2.1.2Columnuas7624LOSLocalread-writemandatoryDisables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.6.2.1.3Columnuas7624LOFLocalread-writemandatoryDisables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.6.2.1.4Columnuas7624AISLocalread-writemandatoryDisables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.6.2.1.5Columnuas7624YELLOWLocalread-writemandatoryDisables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.6.2.1.6Columnuas7624LineCodeViolationLocalread-writemandatoryDisables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.6.2.1.7Columnuas7624CRCLocalread-writemandatoryDisables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.6.2.1.10Columnuas7624ESLocalread-writemandatoryDisables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=1-4 [i]nterface=1-3 [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.6.2.1.11Columnuas7624BESLocalread-writemandatoryDisables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.6.2.1.12Columnuas7624SESLocalread-writemandatoryDisables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.6.2.1.13Columnuas7624UASLocalread-writemandatoryDisables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=1-4 [i]nterface=1-3 [L]ine=5 [i]nterface=0
1.3.6.1.4.1.498.18.1.6.2.1.14Columnuas7624OutofSyncLocalread-writemandatoryDisables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=1-4 [i]nterface=1-3
1.3.6.1.4.1.498.18.1.6.2.1.15Columnuas7624NoSealingCurrentLocalread-writemandatoryDisables or enables the alarm on the Major buss or Minor Buss. SCinstance: [L]ine=1-4 [i]nterface=1-3
1.3.6.1.4.1.498.18.2Nodeuas7624
1.3.6.1.4.1.498.18.2.1Nodeuas7624Alarms
1.3.6.1.4.1.498.18.2.1.1Nodeuas7624NoResponseAlm
1.3.6.1.4.1.498.18.2.1.2Nodeuas7624DiagRxErrAlm
1.3.6.1.4.1.498.18.2.1.3Nodeuas7624PowerUpAlm
1.3.6.1.4.1.498.18.2.1.4Nodeuas7624LossOfSignalAlm
1.3.6.1.4.1.498.18.2.1.5Nodeuas7624LossOfFrameAlm
1.3.6.1.4.1.498.18.2.1.6Nodeuas7624AisAlm
1.3.6.1.4.1.498.18.2.1.7Nodeuas7624YellowAlm
1.3.6.1.4.1.498.18.2.1.8Nodeuas7624OutofSyncAlm
1.3.6.1.4.1.498.18.2.1.9Nodeuas7624SealingCurrentNoContAlm
1.3.6.1.4.1.498.18.2.1.10Nodeuas7624UASAlm
1.3.6.1.4.1.498.18.2.1.11Nodeuas7624ESAlm
1.3.6.1.4.1.498.18.2.1.12Nodeuas7624LineCodeViolationAlm
1.3.6.1.4.1.498.18.2.1.13Nodeuas7624CRCAlm
1.3.6.1.4.1.498.18.2.1.14Nodeuas7624BESAlm
1.3.6.1.4.1.498.18.2.1.15Nodeuas7624SESAlm
1.3.6.1.4.1.498.18.2.1.16Nodeuas7624MajorBERAlm
1.3.6.1.4.1.498.18.2.1.17Nodeuas7624MinorBERAlm