MIB Viewer

HW-IMAPV2NORTHBOUND-TRAP-MIB

68 objects
This MIB defines the managed objects that are used by the function interfaces of the SNMP Northbound Interface.
Imported Objects
SNMPv2-CONFMODULE-COMPLIANCE NOTIFICATION-GROUP OBJECT-GROUP
SNMPv2-SMIenterprises Integer32 IpAddress MODULE-IDENTITY NOTIFICATION-TYPE OBJECT-IDENTITY OBJECT-TYPE
OIDNameAccessStatusDescription
1.3.6.1.4.1.2011IdentityhuaweiThis MIB defines the managed objects that are used by the function interfaces of the SNMP Northbound Interface.
1.3.6.1.4.1.2011.2Nodeproducts
1.3.6.1.4.1.2011.2.15NodehwNetManagement
1.3.6.1.4.1.2011.2.15.1NodehwNmAgent
1.3.6.1.4.1.2011.2.15.1.3NodehwNmFault
1.3.6.1.4.1.2011.2.15.1.3.5ScalarthirdNMSFaultFilterread-writecurrentIP:Port:AlarmLevelFilter:AlarmCategoryFilter AlarmLevelFilter = xxxx (Critical, Major, Minor, Warning) (1 - filter, 0 - report) AlarmCategoryFilter = yyyyyy (E…
1.3.6.1.4.1.2011.2.15.1.3.6ScalarhwNmClearAlarmsread-writecurrentThis provides the functionality of clearing alarms to third party NMS. The alarms can be cleared based on alarm serial number. Multiple serial numbers are sepa…
1.3.6.1.4.1.2011.2.15.1.3.7ScalarhwNmAcknowledgeAlarmsread-writecurrentThis provides the functionality of acknowledging alarms to third party NMS. The alarms can be acknowledged based on alarm serial number. Multiple serial number…
1.3.6.1.4.1.2011.2.15.1.3.8ScalarhwNmUnAcknowledgeAlarmsread-writecurrentThis provides the functionality of unacknowledging alarms to third party NMS. The alarms can be unacknowledged based on alarm serial number. Multiple serial nu…
1.3.6.1.4.1.2011.2.15.1.7NodehwNmNorthboundEvent
1.3.6.1.4.1.2011.2.15.1.7.1NodehwNmNorthboundEventInfo
1.3.6.1.4.1.2011.2.15.1.7.1.0IdentityhwNmNorthboundEventTrapcurrentEvent Traps
1.3.6.1.4.1.2011.2.15.1.7.1.0.1NotificationhwNmNorthboundEventNotifycurrentNotification for real-time alarm.
1.3.6.1.4.1.2011.2.15.1.7.1.0.3NotificationhwNmNorthboundEventNotifyCriticalcurrentNotification for real-time alarm whose level is Critical.
1.3.6.1.4.1.2011.2.15.1.7.1.0.4NotificationhwNmNorthboundEventNotifyMajorcurrentNotification for real-time alarm whose level is Major.
1.3.6.1.4.1.2011.2.15.1.7.1.0.5NotificationhwNmNorthboundEventNotifyMinorcurrentNotification for real-time alarm whose level is Minor.
1.3.6.1.4.1.2011.2.15.1.7.1.0.6NotificationhwNmNorthboundEventNotifyWarningcurrentNotification for real-time alarm whose level is Warning.
1.3.6.1.4.1.2011.2.15.1.7.1.0.7NotificationhwNmNorthboundEventNotifyIndefinitelycurrentNotification for real-time alarm whose level is Indefinitely.
1.3.6.1.4.1.2011.2.15.1.7.1.0.8NotificationhwNmNorthboundEventNotifyUnknownSeveritycurrentNotification for real-time alarm whose level is UnknownSeverity.
1.3.6.1.4.1.2011.2.15.1.7.1.1ScalarhwNmNorthboundNENameread-onlycurrentThe name of network element,string (255)
1.3.6.1.4.1.2011.2.15.1.7.1.2ScalarhwNmNorthboundNETyperead-onlycurrentDevice type of element,string(64)
1.3.6.1.4.1.2011.2.15.1.7.1.3ScalarhwNmNorthboundObjectInstanceread-onlycurrentInstance of element,such as number of Rack, Frame, Slot, Subslot, Port and so on,string(255)
1.3.6.1.4.1.2011.2.15.1.7.1.4ScalarhwNmNorthboundEventTyperead-onlycurrentType of Event,string(64)
1.3.6.1.4.1.2011.2.15.1.7.1.5ScalarhwNmNorthboundEventTimeread-onlycurrentTime at which the alarm was generated,string(64). It can be of any of the following formats: 1. Local Time without timezone information - 'YYYY/MM/DD - hh:mm:s…
1.3.6.1.4.1.2011.2.15.1.7.1.6ScalarhwNmNorthboundProbableCauseread-onlycurrentProbable cause of the alarm, string(255)
1.3.6.1.4.1.2011.2.15.1.7.1.7ScalarhwNmNorthboundSeverityread-onlycurrentLevel of Alarm., string(64) It can be any of the following: Critical, Major, Minor, Warning, Indeterminate.
1.3.6.1.4.1.2011.2.15.1.7.1.8ScalarhwNmNorthboundEventDetailread-onlycurrentAlarm ID and detail information, string(4096)
1.3.6.1.4.1.2011.2.15.1.7.1.9ScalarhwNmNorthboundAdditionalInforead-onlycurrentAdditional information of device, such as Country, City and so on, string(255)
1.3.6.1.4.1.2011.2.15.1.7.1.10ScalarhwNmNorthboundFaultFlagread-onlycurrentThe flag which specifies whether the alarm is an Event, Fault, Recovery, Acknowledge Unacknowledge or Change.
1.3.6.1.4.1.2011.2.15.1.7.1.11ScalarhwNmNorthboundFaultFunctionread-onlycurrentThe function type of the alarm.It can be one of these values:'Power','Environment','Signal','Relay','Hardware','Software','Run','Communication','Service','Proc…
1.3.6.1.4.1.2011.2.15.1.7.1.12ScalarhwNmNorthboundDeviceIPread-onlycurrentIP address of the device
1.3.6.1.4.1.2011.2.15.1.7.1.13ScalarhwNmNorthboundSerialNoread-onlycurrentThe serial number of alarm.
1.3.6.1.4.1.2011.2.15.1.7.1.14ScalarhwNmNorthboundProbableRepairread-onlycurrentAlarm repair recommendations.
1.3.6.1.4.1.2011.2.15.1.7.1.15ScalarhwNmNorthboundResourceIDsread-onlycurrentThe ID of the resource.
1.3.6.1.4.1.2011.2.15.1.7.1.16ScalarhwNmNorthboundsAdditionalVB1read-onlycurrentAdditional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml
1.3.6.1.4.1.2011.2.15.1.7.1.17ScalarhwNmNorthboundsAdditionalVB2read-onlycurrentAdditional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml
1.3.6.1.4.1.2011.2.15.1.7.1.18ScalarhwNmNorthboundsAdditionalVB3read-onlycurrentAdditional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml
1.3.6.1.4.1.2011.2.15.1.7.1.19ScalarhwNmNorthboundsAdditionalVB4read-onlycurrentAdditional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml
1.3.6.1.4.1.2011.2.15.1.7.1.20ScalarhwNmNorthboundsAdditionalVB5read-onlycurrentAdditional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml
1.3.6.1.4.1.2011.2.15.1.7.1.21ScalarhwNmNorthboundsAdditionalVB6read-onlycurrentAdditional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml
1.3.6.1.4.1.2011.2.15.1.7.1.22ScalarhwNmNorthboundsAdditionalVB7read-onlycurrentAdditional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml
1.3.6.1.4.1.2011.2.15.1.7.1.23ScalarhwNmNorthboundsAdditionalVB8read-onlycurrentAdditional information of the alarm. These 8 fields are decided by configuration in snmpsvc.xml
1.3.6.1.4.1.2011.2.15.1.7.1.24ScalarhwNmNorthboundEventNameread-onlycurrentThe name of event,string (4096)
1.3.6.1.4.1.2011.2.15.1.7.1.25ScalarhwNmNorthboundReasonIDread-onlycurrentThe Reason ID of the alarm
1.3.6.1.4.1.2011.2.15.1.7.1.26ScalarhwNmNorthboundFaultIDread-onlycurrentThe Fault ID of the alarm
1.3.6.1.4.1.2011.2.15.1.7.1.27ScalarhwNmNorthboundDeviceTyperead-onlycurrentThe Device Type ID of the alarm
1.3.6.1.4.1.2011.2.15.1.7.1.28ScalarhwNmNorthboundTrailNameread-onlycurrentTrailName effected by alarm
1.3.6.1.4.1.2011.2.15.1.7.1.29ScalarhwNmNorthboundRootAlarmread-onlycurrentSpecifies if the alarm is a root alarm 0 - Non-root alarm 1 - Root alarm
1.3.6.1.4.1.2011.2.15.1.7.1.30ScalarhwNmNorthboundGroupIDread-onlycurrentThe Group ID of the alarm
1.3.6.1.4.1.2011.2.15.1.7.1.31ScalarhwNmNorthboundMaintainStatusread-onlycurrentmaintain status
1.3.6.1.4.1.2011.2.15.1.7.2NodehwNmNorthboundEventKeepAliveInfo
1.3.6.1.4.1.2011.2.15.1.7.2.0IdentityhwNmNorthboundEventKeepAliveInfoTrapcurrentKeepAlive Trap
1.3.6.1.4.1.2011.2.15.1.7.2.0.2NotificationhwNmNorthboundEventKeepAlivecurrentNotification for keep alive traps.
1.3.6.1.4.1.2011.2.15.1.7.2.1ScalarhwNmNorthboundKeepAliveread-onlycurrentKeep Alive
1.3.6.1.4.1.2011.2.15.1.7.7NodehwNmNorthboundEventSynchronization
1.3.6.1.4.1.2011.2.15.1.7.7.1NodehwNmNorthboundEventSynchronizationStart
1.3.6.1.4.1.2011.2.15.1.7.7.1.0IdentityhwNmNorthboundEventSynchronizationStartTrapcurrentSync Start Trap
1.3.6.1.4.1.2011.2.15.1.7.7.1.0.9NotificationhwNmNorthboundEventSynchronizationStartNotifycurrentNotification indicates the beginning of alarm synchronization.
1.3.6.1.4.1.2011.2.15.1.7.7.2NodehwNmNorthboundEventSynchronizationQueryResult
1.3.6.1.4.1.2011.2.15.1.7.7.2.0IdentityhwNmNorthboundEventSynchronizationQueryResultTrapcurrentSync Notification Trap
1.3.6.1.4.1.2011.2.15.1.7.7.2.0.10NotificationhwNmNorthboundEventSynchronizationQueryResultNotifycurrentNotification carries the query result of alarm synchronization.
1.3.6.1.4.1.2011.2.15.1.7.7.3NodehwNmNorthboundEventSynchronizationEnd
1.3.6.1.4.1.2011.2.15.1.7.7.3.0IdentityhwNmNorthboundEventSynchronizationEndTrapcurrentSync End Trap
1.3.6.1.4.1.2011.2.15.1.7.7.3.0.11NotificationhwNmNorthboundEventSynchronizationEndNotifycurrentNotification indicates the end of alarm synchronization.
1.3.6.1.4.1.2011.2.15.1.7.7.3.1ScalarhwNmNorthboundEventSynchronizationEndStatusread-onlycurrentIt shows the result of alarm synchronization. 1 means the alarm synchronization successfully ended. 2 means the alarm synchronization is stopped by the NMS's c…
1.3.6.1.4.1.2011.2.15.1.7.7.3.2ScalarhwNmNorthboundEventSynchronizationEndStatusDetailread-onlycurrentThe detail description of the alarm synchronization end status.
1.3.6.1.4.1.2011.2.15.1.7.7.4ScalarhwNmNorthboundEventSynchronizationCommandStartread-writecurrentThis node is to be set to start the alarm synchronization. The format to query alarms is:- IP:port:start time:end time Query time can be UTC time, Local time o…
1.3.6.1.4.1.2011.2.15.1.7.7.5ScalarhwNmNorthboundEventSynchronizationCommandStopread-writecurrentThis node is to be set to stop the alarm synchronization. It should be set as NMS's IP:port,and the agent will stop alarm synchronization for the IP and port s…